To inquire about any e-tender the Andaman & Nicobar Islands government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder one can find every eprocurement Punjab tender on BidAssist. BidAassist has collated each and every Eproc Andaman & Nicobar Island Tender on its website. Looking for Andaman & Nicobar Island tenders online or going through the cumbersome government websites for it, has been made easier with the help of BidAssist.
Bharat Sanchar Nigam Limited - BSNL Tender
Civil And Construction
Civil Works Others
Eprocure
Opening Date28 Aug 2024
Closing Date4 Sep 2024
Tender Amount₹ 2,06,261
Costs
EMD
₹ 4,130Document Cost
₹ 590Tender Fee
Refer Documents
Summary
Arresting Of Leakage In Parapet Wall Junctions , Cleaning Of Blocked Septic Tank And Manholes, Claening Of Drains, Repairing Of Wooden Doors, Repalcing Of Fully Damaged Wooden, Pvc Doors And Other Allied Civil Works At Bsnl Bhavan, Port Blair
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_BSNL_206328_1Bid Award Id
ViewTender No
30/NIT/CD-PB/AN/2024-25Tender Authority
Bharat Sanchar Nigam Limited ViewPurchaser Address
-Website
http://bsnl.co.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer’s specification.
8
-
286.85
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : (a) 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
0.2
-
286.85
Centering and shuttering including strutting, propping etc. and removal of form for : (a) Foundations, footings, bases of columns, etc. for mass concrete
4
-
286.85
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.
50
-
286.85
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately).(a) Kiln seasoned and chemically treated hollock wood.
0.04
-
286.85
Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:- Butt hinges and necessary screws shall be paid separately) (a) Kiln seasoned and chemically treated hollock wood (i) 30 mm thick shutters
1
-
286.85
Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick : (a) Kiln seasoned and chemically treated hollock wood.
1
-
286.85
Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete.
1
-
286.85
Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : (a) 125x64x1.90 mm
15
-
286.85
Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete : (a) 250x16 mm
5
-
286.85
Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete : (a) 250x10 mm
8
-
286.85
Providing and fixing aluminium handles ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : (a) 125 mm
10
-
286.85
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS :5382 leaving 10 mm gap for thermal expansion. (a) Shoe (Plain) (i) 110 mm Shoe
4
-
286.85
12 mm cement plaster finished with a floating coat of neat cement of mix : (a) 1:3 (1 cement: 3 fine sand)
28
-
286.85
Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50mm hardwood plugs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. (a) 110 mm
16
-
286.85
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :
-
-
-
Two or more coats on new work.
11
-
286.85
One or more coats on Old work.
35
-
286.85
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
33
-
286.85
Distempering with 1st quality acrylic distemper, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour.
-
-
-
One coat.
42
-
286.85
Two coats.
75
-
286.85
Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete.
75
-
286.85
Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kgper sqm including pointing in white cement mixed with pigment of matching shade complete.
4
-
286.85
Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete. (a) 10 litre capacity - White
2
-
286.85
Cleaning of terrace/loft water storage tank (inside surface area) upto 2000 litre capacity at all heights with coconut brushes, duster etc., removal of silt, rubbish from the tank and cleaning the tank with fresh water disinfecting with bleaching powder @ 0.5gm per litre capacity of tank, including marking the date of cleaning on the side of tank body with the help of stencil and paint and disposing of malba, all complete as per direction of Engineer-in-Charge. (The old date already written on tank should be removed with paint remover or black paint and if date is not written with the stencil or old date is not removed deduction will be made @ Rs. 0.10 per litre if during cleaning any GI fittings or ball cock is damaged that is to be repaired by contractor at his own cost and nothing extra will be paid on this account)
7500
-
286.85
Cleaning and de-silting of gully trap chamber, including removal of rubbish mixed with earth etc. and disposal of same, all as per the direction of Engineer-in-charge.
4
-
286.85
Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved.
7.5
-
286.85
Providing and fixing approved quality 25 mm thick PVC door shutter with frame of brand Rajashree or rate equvalent excluding all fixtures fittings.
1.54
-
286.85
Making scaffolding with bamboo and ropes with good quality bamboo props with vertical spacing not more than 1.80 m c/c and horizontal spacing not more than 1.20 m c/c tying it with building at intermediate points and making arrangement to inspect the work by providing access platforms to work upto floor V level including removing the same after completion of work, taking all care against safety of work force as per direction of the Engineer-in-charge.( Height and length of scaffolding to be measured)
25
-
286.85
Cutting of tree branches touching departmental buildings at a height upto 12 metres above ground level by taking all care against life and adjecent property including disposal of same at a distance of 100mtr from work site as per direction of the Engineer-in-charge.
1
-
286.85
Repair to existing wooden door shutter by cutting to required size, replacing damaged styles/rails/panels as per requirement, fixing of old good fittings and refixing of repaired door shutters to existing door frames, including replacement of hinges with screws, etc. all complete as per the direction of the Engineer-in-charge.(New wooden members fixed if any, shall be paid extra).
4
-
286.85
Rearranging PVC water supply lines 25 mm to 40 mm diameter for a length approximately about 68 m after removing from parapet and roof slab junction corner so as provide leak proof treatment at roof slab/parapet junctions, including cutting, jointing with necessary PVC pipe fittings etc complete as directed by the engineer in charge
1
-
286.85
Cleaning of under ground sump including disposal of slit and rubbish, all as per direction of Engineer-in-Charge. The cleaning shall consist following operations:- (i) Entire surface area of the sump shall then scrubbed thoroughly with wire brush etc. and pressure washed with water.(ii) Chlorination of RCC internal surface by liquid chlorine (iii) Tank shall be emptied of water by pumping & bottom shall be cleaned of slit and other deposits. (iv) The treated surface shall be dried using air jetting and all loose particles shall be removal from the surface and providing. etc. as per direction of Engineer-in-Charge.
30
-
286.85
Providing approved quality bituminous tarfelt water proofing sheets of 0.80 mm thickkness over expansion joints Over the primer coat the layer of membrane shall be laid using Butane Torch and sealing all joints etc, and preparing the surface complete as directed by the Engineer in Charge
10
-
286.85
Mechanical cleaning of Septic Tank by using mechanical cleaning mechine by suction, pumping, vaccum cleaning and removing all the waste liquid and sludge from the septic tank and disposaing the waste at Municipal dumping ground. The rate includes all mechinery and workmen required and all incidental charges during pumping, filling, transporting etc complete as directed by the Engineer-in-charge. For capacity up to 45,000 Liters.
1
-
286.85
Removal of debris, slush, waste materials and any other obstructing material from the drain of size up to 450mmX750mm which is passing through the rear side of BSNL Bhawan including removing and refixing of existing RCC cover slabs after completion of work etc all complete as directed by the engineer in charge.
35
-
286.85
Cleaning of blocked sewage manholes by removing deposited night soil and other waste materilas from manholes and connected sewer lines upto septic tank by rodding and flushing with water and make the system properly functionable as directed by the Engineer -in- charge. (Rate per Each manhole)
5
-
286.85
Replacement of old damaged polyethelene cover for water storage tank by providing and fixing polyethelene cover for water storage tank with P.V.C. bolts and nuts and locking arrangement all complete as directed by the Engineer -in -charge. For PVC tanks up to 2000 Liters
5
-
286.85