Bharat Sanchar Nigam Limited Tender
To inquire about any e-tender the Andaman & Nicobar Islands government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder one can find every eprocurement Punjab tender on BidAssist. BidAassist has collated each and every Eproc Andaman & Nicobar Island Tender on its website. Looking for Andaman & Nicobar Island tenders online or going through the cumbersome government websites for it, has been made easier with the help of BidAssist.
Bharat Sanchar Nigam Limited - BSNL Tender
Civil And Construction
Building Construction
Eprocure
Opening Date7 Nov 2024
Closing Soon16 Nov 2024
Tender Amount₹ 3,61,044
Costs
EMD
₹ 7,220Document Cost
₹ 590Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_BSNL_213680_1Tender No
37 NIT CD PB AN 2024 25Tender Authority
Bharat Sanchar Nigam Limited ViewPurchaser Address
-Website
http://etenders.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge..
-
-
-
In cement mortar
0.3
-
-
Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead :
-
-
-
Of area 3 sq. metres and below
1
-
-
Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.
-
-
-
For thickness of tiles 10 mm to 25 mm
15
-
-
Dismantling 15 to 40 mm dia G.I. pipe including stacking of dismantled pipes (within 50 metres lead) as per direction of Engineerin-Charge.
-
-
-
Internal Work- Exposed on wall
5
-
-
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
-
-
-
1:2:4 (1 cement : 2 coarse sand(zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
0.5
-
-
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.
-
-
-
In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works.
125
-
-
Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kgper sqm including pointing the joints with white cement mixed with pigment of matching shade complete.
14
-
-
Providing and laying Ceramic glazed floor tiles of size 300x300 mm(thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @3.3kg/sqm including pointing the joints with white cement and matching pigments etc., complete.
4
-
-
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-Charge) of total coated thickness 0.50mm (base metal of minimum 0.45mm thickness with total coating thickness of 0.05mm) with zinc coating 120 grams per sqm as per IS:277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in- charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
3
-
-
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :
-
-
-
Two or more coats on new work.
5
-
-
Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour.
-
-
-
One coat.
95
-
-
Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre. of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour.
-
-
-
Two coats.
330
-
-
Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content.
-
-
-
With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre.
18
-
-
Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete.
440
-
-
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :
-
-
-
One or more coats on old work.
70
-
-
Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade :
-
-
-
Old work (Two or more coats applied @ 1.43 ltr/ 10 sqm) over existing cement paint surface.
160
-
-
Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground , all complete as per directions of Engineer-In-Charge.
-
-
-
With cement mortar 1:4 (1 cement : 4 fine sand).
10
-
-
Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings andfixtures complete, including cutting and making good the walls and floors wherever required :
-
-
-
W.C. pan with ISI marked white solid plastic seat and lid
1
-
-
Providing and fixing wash basin with C.I. brackets, 15 mm PTMT pillar cock, 32 mm PTMT waste coupling of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required. White Vitreous China Flat back wash basin size 550x400 mm with single 15 mm PTMT pillar cock.
1
-
-
Providing and fixing solid plastic seat with lid for pedestal type W.C. pan complete :
-
-
-
White solid plastic seat with lid
2
-
-
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.
-
-
-
Flexible pipe
-
-
-
32 mm dia
1
-
-
Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :
-
-
-
Rectangular shape 453x357 mm
1
-
-
Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.
-
-
-
600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms.
1
-
-
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. : Internal work - Exposed on wall
-
-
-
20 mm nominal outer dia. Pipes.
4
-
-
25 mm nominal outer dia .Pipes.
4.5
-
-
Providing and fixing PTMT bib cock of approved quality and colour.
-
-
-
15mm nominal bore, 86 mm long. Weighing not less than 88 gms.
2
-
-
Providing and fixing PTMT angle stop cock 15 mm nominal bore. Weighing not less than 85 gms.
4
-
-
Providing and fixing unplasticised P.V.C. connection pipe with PTMT Nuts, collar and bush of approved quality and colour.
-
-
-
15 mm nominal bore with 45 cm length.
2
-
-
Chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of Engineer-In-Charge
-
-
-
25 mm average thickness
8
-
-
Cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of Engineer-In-Charge.
-
-
-
Bars upto 12 mm diameter
20
-
-
Providing, mixing and applying bonding coat of approved adhesive on chipped portion of RCC as per specifications and direction of Engineer-In-charge complete in all respect.
-
-
-
SBR Polymer (@10% of cement weight) modified cementitious bond coat @ 2.2 kg cement per sqm of surface area mixed with specified proportion of approved polymer
8
-
-
Providing, mixing and applying SBR polymer (of approved make) modified Cement mortar in proportion of 1:4 (1 cement: 4 graded coarse sand with polymer minimum 2% by wt. of cement used) as per specifications and directions of Engineer-in-charge. Note: Measurement and payment: The pre-measurement of thickness shall be done just after the surface preparation is completed and Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding / tapping with a blunt metal instrument and/or the 75mm size cube crushing strength at the end of 28 days to be not less than 30 N/Sqmm2).
-
-
-
25 mm average thickness in 2 layers.
8
-
-
Providing and fixing approved quality 25 mm thick PVC door shutter with frame of brand syntex or equivalent including all fixtures fittings etc complete as per the direction of the Engineer in Charge.
1.5
-
-
Providing and fixing PTMT health faucet with 1m long pvc hose of approved brand and manufacture and of approved shade - 15mm
3
-
-
Providing and fixing PVC-SWR multi floor trap of self cleansing design with PVC grating over top inlet complete, including cost of cutting and making good the floors :
-
-
-
a) 100 mm inlet and 75mm outlet with 100mm height
3
-
-
Providing and fixing on wall face unplasticised Rigid PVC SWR pipes conforming to IS : 13592 Type-B, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion
-
-
-
110 mm dia pipe
1
-
-
75 to 80 mm dia pipe
4
-
-
Repair to existing wooden door shutter by cutting to required size, replacing damaged styles/rails/panels as per requirement, fixing of old good fittings and refixing of repaired door shutters to existing door frames, including replacement of hinges with screws, etc. all complete as per the direction of the Engineer-in-charge.(New wooden members fixed if any, shall be paid extra).
2
-
-
Cleaning terrace of departmental buildings upto floor V level including mumty, rain water mouths etc. and disposal of rubbish in municipal dumpling area within a lead of 100 meter. (a) Terrace area above 100 Sqm. upto 250Sqm
1
-
-
Credit to agency for following material recovered by dismantling
-
-
-
GI/bars pipes and fittings
25
-
-
PTMT taps/stop cock/connection pipes
5
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%