Andaman And Nicobar Islands Integrated Development Corporation Limited Tender
To inquire about any e-tender the Andaman & Nicobar Islands government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder one can find every eprocurement Punjab tender on BidAssist. BidAassist has collated each and every Eproc Andaman & Nicobar Island Tender on its website. Looking for Andaman & Nicobar Island tenders online or going through the cumbersome government websites for it, has been made easier with the help of BidAssist.
Andaman And Nicobar Islands Integrated Development Corporation Limited - ANIIDCO Tender
Civil And Construction
Building Construction
Eprocure
Opening Date1 Apr 2022
Closing Date20 Apr 2022
Tender Amount₹ 10,99,245
Costs
EMD
₹ 22,000Document Cost
Refer DocumentsTender Fee
Refer Documents
Summary
Repair And Renovation Of Staff Cafeteria
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2022_ANCVL_5492_1Bid Award Id
ViewTender No
ANIIDCO/CW/22-23/TD-02Tender Authority
Andaman And Nicobar Islands Integrated Development Corporation Limited ViewPurchaser Address
-Website
http://eprocure.andaman.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
1:2:4 (1 Cement : 2 coarse sand (Zone-III) : 4 graded stone aggregate 20 mm nominal size).
2.2
-
-
1:3:6 (1 Cement : 3 coarse sand (Zone-III) : 6 graded stone aggregate 20 mm nominal size).
1.3
-
-
1:4:8 (1 Cement : 4 coarse sand (Zone-III) : 8 graded stone aggregate 40 mm nominal size).
1.5
-
-
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :
-
-
-
1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size)
1.3
-
-
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns,pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :
-
-
-
1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size)
0.5
-
-
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering,shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).
1
-
-
Centering and shuttering including strutting, propping etc. and removal of form for :
-
-
-
Foundations, footings, bases of columns, etc. for mass concrete
5
-
-
Walls (any thickness) including attached pilasters, butteresses,plinth and string courses etc
6.2
-
-
Lintels, beams, plinth beams, girders, bressumers and cantilevers
12.2
-
-
Columns, Pillars, Piers, Abutments, Posts and Struts
10
-
-
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.
-
-
-
Thermo-Mechanically Treated bars of grade Fe-500D or more
135
-
-
Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete above plinth level
-
-
-
Thermo-Mechanically Treated bars of grade Fe-500D or more
85
-
-
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 ement : 3)coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm,including pointing in white cement mixed with pigment of matching shade complete.
15
-
-
Providing and fixing factory made uPVC door frame made of uPVC extruded sections having an overall dimension as below (tolerance ±1mm), with wall thickness 2.0 mm (± 0.2 mm), corners of the door frame to be Jointed with galvanized brackets and stainless steel screws, joints mitred and Plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 X 19 mm and 1mm (± 0.1 mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete as per manufacturer’s specification and direction of Engineerin- charge
-
-
-
Extruded section profile size 48x40 mm
10
-
-
Providing and fixing to existing door frames
-
-
-
24 mm thick factory made PVC door shutters made of styles and rails of a uPVC hollow section of size 59x24 mm and wall thickness 2 mm (± 0.2 mm) with inbuilt edging on both sides. The styles and rails mitred and joint at the corners by means of M.S. galvanised/ plastic brackets of size 75x220 mm having wall thickness 1.0 mm and stainless steel srews. The styles of the shutter reinforced by inserting galvanised M.S. tube of size 20x20 mm and 1 mm (± 0.1 mm) wall thickness. The lock rail made up of 'H' section, a uPVC hollow section of size 100x24 mm and 2 mm (± 0.2 mm) wall thickness, fixed to the shutter styles by means of plastic/galvanised M.S. 'U' cleats. The shutter frame filled with a uPVC multi-chambered single panel of size not less than 620 mm, having over all thickness of 20 mm and 1 mm (± 0.1 mm) wall thickness. The panels filled vertically and tie bar at two places by inserting horizontally 6 mm galvanised M.S. rod and fastened with nuts and washers, complete as per manufacturer's specification and direction of Engineer-in-charge. (For W.C. and bathroom door shutter).
3
-
-
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
129.5
-
-
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.
-
-
-
Electric resistance or induction butt welded tubes
822
-
-
Providing and fixing mild steel round holding down bolts with nuts and washer plates complete
32
-
-
Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey,Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete.
5
-
-
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes
-
-
-
75 mm diameter
3
-
-
110 mm diameter
16
-
-
Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.
-
-
-
75x75x75 mm Single tee with door
2
-
-
110x110x110 mm Single tee with door
2
-
-
75 mm Bend 87.5°
2
-
-
110 mmBend 87.5°
2
-
-
Providing ridges or hips of width 60 cm overall width plain G.S. sheet fixed with polymer coated J or L hooks, bolts and nuts 8 mm dia G.I. limpet and bitumen washers complete.
-
-
-
0.63 mm thick with zinc coating not less than 275 gm/m²
27
-
-
Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge.
-
-
-
GI Metal Ceiling Lay in plain Tegular edge Global white color tiles of size 595x595 mm, and 0.5 mm thick with 8 mm drop; made of G I sheet having galvanizing of 100 gms/sqm (both sides inclusive) and electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending.
33
-
-
12 mm cement plaster of mix :
-
-
-
1:4 (1 cement: 4 fine sand)
34
-
-
Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications :
-
-
-
Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of Special primer applied @0.75 ltr /10 sqm
34
-
-
Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge.
-
-
-
With cement mortar 1:4 (1 cement : 4 fine sand)
27
-
-
Distempering with 1st quality acrylic distember (Ready mix) having VOC content less than 50 grams/ litre of approved brand and manufacture to give an even shade :
-
-
-
Old work (one or more coats)
140
-
-
Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the suface smooth including necessay repair to scratches etc complete.
117
-
-
Finishing walls with Acrylic Smooth exterior paint of required shade :
-
-
-
Old work (Two or more coat applied @ 1.67 ltr/ 10 sqm)on existing cement paint surface
117
-
-
Renewing glass panes and refixing existing wooden fillets:
-
-
-
Float glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm)
0.7
-
-
Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge.
-
-
-
Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
1.3
-
-
Dismantling wood work in frames, trusses, purlins and rafters up to 10 metres span and 5 metres height including stacking the material within 50 metres lead :
-
-
-
Of sectional area 40 square centimetres and above
0.95
-
-
Dismantling roofing including ridges, hips, valleys and gutters etc.,and stacking the material within 50 metres lead of:
-
-
-
Asbestos cement sheet
60
-
-
Dismantling cement asbestos or other hard board ceiling or partition walls including stacking of serviceable materials and disposal of unserviceable materials within 50 metres lead.
6.25
-
-
Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required :
-
-
-
W.C. pan with ISI marked white solid plastic seat and lid
2
-
-
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:
-
-
-
White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap
2
-
-
Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
2
-
-
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.
-
-
-
Internal work - Exposed on wall 20 mm nominal outer dia Pipes
8
-
-
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.
-
-
-
External work 25 mm nominal outer dia Pipes
20
-
-
Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 :
-
-
-
15 mm nominal bore
2
-
-
Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931.
-
-
-
15 mm nominal bore
4
-
-
Providing and fixing uplasticised PVC connection pipe with brass unions :
-
-
-
30 cm length 15 mm nominal bore
4
-
-
ELECTRICAL : Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.
-
-
-
Group A
11
-
-
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required
-
-
-
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
11
-
-
2 X 4 sq. mm + 1 X 4 sq. mm earth wire
20
-
-
2 X 6 sq. mm + 1 X 6 sq. mm earth wire
15
-
-
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
-
-
-
20 mm
60
-
-
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
-
-
-
5/6 amps switch
4
-
-
3 pin 5/6 amp socket outlet
4
-
-
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.
-
-
-
1 or 2 Module (75mmX75mm)
3
-
-
3 Module (100mmX75mm)
2
-
-
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
-
-
-
6 way , Double door
1
-
-
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
-
-
-
Single pole
3
-
-
Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
-
-
-
63 A
1
-
-
EARTHING:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
1
-
-
Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.
20
-
-
Non Schedule Items: Providing and fixing health faucet (Jaquar or equivalent make) of approved quality
2
-
-
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone - III) : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well ramm+C80ed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
9.5
-
-
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge)Tata/Everest Make 0.50 mm + 0.05 %, total coated thickness with zinc coating 120 gsm as per IS: 277 in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches while transportation and should be supplied in single length upto 12metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
88.5
-
-
Providing and fixing stainless steel tower bolt of size 150x10 mm
4
-
-
Providing and fixing stainless steel handles of size 100 mm
4
-
-
Providing and fixing of Eaves Board with 18 mm thick WPVC Board Including nuts and bolts as per direction of engineer incharge
50
-
-
Providing cement concrete surface drain with 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40mm nominal size) finished with 1:4 (1 cement : 4 coarse sand (River sand)) including floating coat of neat cement inside the drain and its top and exposed surface including earthwork in excavation and disposal of surplus earth etc. complete.
-
-
-
20cm x 20cm drain.
16
-
-
Providing and laying hollow cement concrete block walling 150mm thick consisting hollow block of size 400x150x200mm of mix 1:3:6(1 cement: 3 coarse sand: 6 graded stone agg. 10mm nominal down size) having a crushing strength of 3.5N/mm2 AT 28 days as per I.S.2185 (Part-I) laid in cement mortar 1:6 (1 cement: 6 coarse sand).
3
-
-
Providing and fixing LED tube light with all necessary fittings. Make : Bajaj/Philips or equivalent to ISI standard.
4
-
-
Providing and fixing LED bulb 18W of ISI standard.
4
-
-
Providing and fixing Celing Fan 1200 mm sweep with regulator of make havelles / Bajaj
3
-
-
Providing and Instalation of Exhast Fan 400 mm sweep of make Havekkies / Bajaj
2
-
-