Western Railway Tender

... More
The WR has issued a formal invitation for competitive bids for the Western Railway project, for Signalling Work In Connection With Improvement & Upgradation Of Various Yards Under Aden/nandurbar Jurisdiction. Of Ukai Songadh-jalgaon Section Of Mumbai Division. in Nandurbar, Maharashtra, with an estimated contract value of Rs. 1,38,00,588. The bid opening date for this tender is 26-05-2025 and the last date for bid submission is 26-06-2025. Interested bidders for Western Railway tender can download the important documents here to check the scope of work, eligibility criteria and technical requirements.

Western Railway - WR Tender

Works
Telecommunication Services
Ireps
Opening Date26 May 2025
Closing Date26 Jun 2025
Tender Amount₹ 1,38,00,588.78 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Main LED Signal lighting unit working on 110v ac as per RDSOspecn. No. RDSO/SPN /199/2010rev.1.1 retrofit table in existingCLS housing (sa23002,s23024/m) Red Aspect.

4

7441

29765.2

... More
Digging of cable trench 0.3 Mtr. Deep and 0.3 Mtr. Wide on Asphalted Platform / Road / Hard rocky area. Refilling with earth leveling of trenches & restoring the original surface of trenches.

20

512

10255.2

... More
Channel Pins MS(Galvanized) single roove, 7 mm suitable for 4mm dia bonding wire as per spec No IRS S 17 & RDSO Drg No. S-69/M.

5000

6

30200

... More
Termination of outdoor cables, main cables laid in location boxes, Cable termination rack etc. at both ends on ARA terminal or on 8 way terminals or on screw less connectors. Both ends 32 of a cable core terminated shall be counted as one terminal. This includes all associated works of pulling out the cable from underground, peeling off insulation, dressing of cable core supported on sting rod with contractor's own material. The work shall be done as per instructions of Rly engineer at site.

4000

23

94800

... More
G.I. Bonding wire soft for track circuit bonding 8 S.W.G. (4mm Dia.) or as per instructions of Engineer In-Charge.

600

68

40902

... More
Disconnect Terminal Block, Screw less type, as per RDSO Spec. No. RDSO/SPN/189/2004. With the latest amendments. Supply of End plate 2.5mm/0.091 in thick as per site requirement.

800

10

8688

... More
Placing of DWC/RCC pipes along with collars in trenches at places of track and road crossings, platform cuttings etc. also for straight cable laying. (Cable laying is covered separately.)

-

-

43

... More
Ground connections, complete set suitable for IRS type/approved TWS point Machine 220mm with hot dip galvanised. as per instruction of site engineer

5

44326

221630

... More
Drilling of holes of different sizes in rails 7.2mm / 12mm / 16mm / 22mm as perinstructions of RailwayEngineer incharge.

4000

35

141320

... More
Supply of BIS(15683:2018) Listed SemiAutomatic Stainless Steel FireExtinguisher with UL approved clean gaswith Auto Manual Reverse Stainless SteelValve having Capacity 4 Kgs and made ofstainless Steel 304 Grade CylinderPressure 14 bar, Range 3-4 , metersvalve body Pressure 58 Die-casted SS-304,Unique valve with a leak-proof design,delivery method nozzle with flexible hosepipe , UL listed HFC-236fa clean Gasshelf life with 10 Years Warranty forleakage. Note- Tender specificauthorization, warranty of OEM , Testcertificate of any NABL approval LAB forClean Gas and BIS(15383:2018) Listedcertificate along with offer / Tender.(Warranty Period : Upto 120 monthsfrom the date of supply) Inspection by Consignee

4

38586

154344

... More
Supply of Digital Earth Resistance tester three terminal type with LED display, 1999 count, KOICO model 5600 or any reputed make approved by engineer in-charge.

4

13356

53427.36

... More
Excavation of cable trench as per cable route plan, 1 Mtr. deep and of 0.3 Mtr. to 0.6 Mtr wide advised by Engineer-in-charge alongside the track in normal (all type) soil/strata, conforming to distances as per cable route plan and refilling. This work includes clearing of route from bushes 36 etc., covering of cable laid in trench by loose soil for a layer of 50mm thickness approximately before covering by bricks. The work shall be done as per the extant practice on Western Railway and instructions of Railway Engineer at site. In case 1m depth of trench is not achievable due to site conditions, specific approval of JA grade officer will be required for each site where trench depth of 1m is not possible. Without the approval of JA Grade officer, no payment for trenching will be made for trench depth less than 1m.

300

839

251700

... More
Main Signal Post Tubular 140 mm Dia, 5.6 Mtr Length as perIRS: S-6/81 or Latest & RDSO Drg. No. SA-24625 (Advance).

4

10895

43581.64

... More
Ground connections, complete set suitable for IRS type / approved point Machine for ordinary turnout with tongue attachment insulation and other insulation as per RDSO Drg. S/3361@47>47@63 (for IRS type point machine) with latest amendments. However the ground connection shall be procured only after confirmation from Railway engineer as per site condition /type of machine/turnout.

-

-

8

... More
Shifting of existing Signal along with foundation as per site requirement. This inclusive of required labour, machinery like hydra, JCB etc.

4

8199

32798.32

... More
Installation of Apparatus Cases with miniature 'E' type lock on CC foundation. This includes filling of location foundations with river bed sand and plastering on top of the sand. 'E' Type lock will be provided by Railway. Half Case

4

657

2628.6

... More
Supply of Copper Bus Bar 200 x 25 x 6 mm SEEB to terminate earth rod.

-

-

48

... More
Supply of SS Location box made of SplGrade SS 304 of size as per drg. 39 No.DRM/SG/945 (Half app. Case).Dimension of Case should be as perDRM/SG/945. It includes Angle frameRelay frame fixture , earthing Rod ,Drawing Board, Glass ReinforcedPolyester Sheet Moulding Compoundssheet for fixing ARA terminal, Lock etc.as per WR CSTE Drg No. 6285.The manufacturer's certificate in regard tograde of stainless steel and test report shall be submitted at the time of supply.

4

51998

207992.24

... More
Transparent cover sub assembly complete with Cover support LH RH, 853087001-S as per RDSO, approved CG drg. No. CSQ-10920 10915.

10

368

3681.6

... More
Supply of signal no plate as per Drg no CSTE Drg No CSTE/6186.

-

-

29

... More
Installation of Maintenance Free Earth Electrode for Maintenance Free Earth spec of RDSO/SPN/197/2008.

-

-

26

... More
Exothermic welding for any indoor Work as per instructions of site incharge.

-

-

29

... More
PVC Jacketed wire rope for track lead connections. PVC jacketed wire rope should be of 5 Galvanized steel wire rope 6mm dia (6x19 stranded wire with steel core of 6 mm dia) sheathed with PVC 2mm wall thickness, overall thickness being 10mm. PVC sheath should be made of type 6 compound as per IS 5831 of 1970.Reclaimed or recycled material should not be used.

4

5553

22212.68

... More
Fixing of Electrical Point Machine on the extended sleepers at points as per std. practice and as per RDSO Drg. No.(S) 34S4orlatest as per Section of Rails used. ltem includes Fixing ground connection, Adjusting opening of the switches and adjusting the point machine with crank handle. The item also includes supply and fixing of Gl pipes with flange for taking cable into point machine and junction box (Gland pipe) for points. Complete material for installation like ME34 2 junction box with 1Omm hylum sheet, Gl pipes, Wiring materials, various fixing nuts & bolts including castle nuts, Spring washers will be supplied by the contractor. All smithy & fitting works required at site for complete installation done by contractor. lnstallation of gauge tie plate & providing insulation for gauge tie plate & providing insulated William Stretcher Bar will be done by Railways. (Point insulation material is covered under Schedule-A). Item also includes closing of extra holes in ME 34 box by GI/MS sheet to be supplied by contractor. (Electrical Point Machine with ground connections are covered under Sch A)

29

27878

808473.6

... More
Design and supply of cable courage plan, location particulars, Cable termination rack particulars, cable meggeringreport, earth resistance particulars, Traction bonding diagram, 1/2 wire count sheet and any other drawing in AutoCAD inA3/A4 size. The contractor shall initially supply 3 9 sets of circuits complete for approval of Railways. Railways will return one set to the contractor duly approved with alterations/corrections, if any. The contractor shall incorporate Railway's alterations/corrections in the tracings without any deviation and submit all tracings complete in all respects to the Railways along with PENDRIVE & 4 sets of final approved drawings. This includes designing of cable coreage plan based upon I.P in consultation with engineer-in-charge For small/medium yards. Station

4

63698

254792

... More
Erection of Position Light shunt signal on Offset bracket on main signal.

-

-

14

... More
Providing Ferrules of cabletermination as per latest policyissued by HQ. The work to be 31 donewithout disturbing existingconnections. Contractors willprovide ferrules as per colour codeand nomen clature given byEngineer incharge. As far aspossible self locking type ferrulesto be provided. Type / design offerrules may be approved fromrailway before supply.

4000

4

17320

... More
Disconnect Terminal Block, Screw less type, 4-wire front entry (Two in-put & Two out- 42 put) The color will be decided by Engineer - in - Charge. (Preferably In Blue, Red & Grey Colors in the ratio of 1:2:3). as per RDSO Spec. No. RDSO/SPN/189/2004. With latest amendments. Note: Make to be approved by Railway before supply

4000

58

234120

... More
Digital Multimeter of Fluke 287 Industrial, True RMS with temperature, Analog bar graph, Digital display, Backlight, 1000V AC/DC, measure up to 10A, 20A for up to 30 seconds or Superior.

4

44774

179098.08

... More
Excavation and Casting of Apparatus Case foundation with contractor's own materials 17 including cement and anchor bolts of standard size. The required scaffolding Ferma etc. for Casting of foundation will have to be brought by the contractor at his own cost. Single Case as per Drg No SK 748 or CSTE/5074 or SSLocation

8

7162

57301.04

... More
Supply and installation of RCC cable route marker engraved and painted on both side along the route every 50mtr and route diversion as per Drg. No 4014/00/CC4 or latest/ Stone marker.

320

412

132051.2

... More
Position Light Shunt Signal Unit Complete with Post (made of GI Pipe of 80 mm 33 Diameter Medium Class IS Spec. No. IS: 1239 Pt. 1/1990) Base, Hood, and Cover, etc. as per Drg. No. SA-23840, Signal Number Plate, suitable for LED Signal Lighting Unit. (Supply of LED Unit is not covered in this item).

4

4530

18120.28

... More
Road Measuring Cycle, made of Aluminum with 05 digit counter, foldable with the bag.

-

-

23

... More
Supply of Fiber/ SMC/FRP/RCC Earth Chamber.

-

-

47

... More
Battery operated Rail core drilling machine with quick action clamping system on track along with 18 mm TCT rail core drill. Maximum core cutting capacity 36 mm, rated speed 250/450 25 RPM. Battery type Lion, Battery voltage 50V, battery pack capacity 4AH. Number of batteries supplied- 2 Nos with suitable charger 1 no. Special designed pressurized internal spindle cooling to give maximum life of core cutter by avoiding heating. 3 sets of 22, 13, 16, 7.2 gauze drills adapters to be provided along with the machine. Weight of the machine 18.5 kgs maximum. Make- Eibenstok, Bosch, KPT with all accessories suitable for the Railway Signalling and along with carrying case.

2

112848

225696.24

... More
Supply of Copper Bus Bar 150 x 25 x 6 mm SEEB.

-

-

49

... More
Contractor Unit Assly CU Base Assly 851241034-S, RDSO Drg.No. RDSO/S 10911, CG Drg.No.CHS-10911.

10

12155

121554.2

... More
- Radiodetection Precision Pipe and Cable locator / Route tracer Brand: Radiodetection or similar as per technical specification

2

499995

999990

... More
Supply of Standard Tools set.

-

-

22

... More
Digging of cable pit (min2x2x1m) as per instruction of Site Engineer, supplying and filling of sand before and after coiling the cables, covering top of the cable pit with stones and providing brick masonry on all four sides of the cable pit and plastering thereafter.

2

12567

25135.66

... More
Waterproof Galvanized MAIN COVER ASSEMBLY complete spare for POINT Machine comprising of Main cover, CRANK HANDLE HOLE SUB. ASSY, KEY HOLE LOCK SUB. Assy, door lock, 13 rubber gasket of main cover assy, rubber gasket (c.h. Hole lock assy.), crank handle hole lock base, crank handle hole lock lid, pin (for c.h. Hole lock s/a), rubber gasket (c.h. Hole Lock assy. Locking cam, key code 856051010-s along with Fixing material to trap accumulated air as per Drg no R-ST- 12161, modification in cover as per consignee requirement. Thickness of cover material:- 2mm, galvanizing and power coating shall be done on cover. (Inspection Agency-Consignee)

10

17211

172114.8

... More
Position Light Shunt Signal Unit Complete, with offset bracket, hood, Cover etc. as per Drg. No. SA-23840 suitable for LED Signal Lighting Unit. (Supply of LED Unit is not covered in this item).

4

3359

13438.96

... More
4 Aspect LED Signal housing made of SS-304 (1.5mm thick) duly powder coated32 inblack with back ground plates, prewiringfor LED signals, terminal strip, reflectivestrips on rear side, ventilation and polemounting attachment the design shall beconfirm to IP-54.

2

33303

66607.72

... More
ARA Terminal blocks with links made of PBT Spec No.s/75/2006 (Rev - 2) with latest amendments and RDSO Drg.No.SA-23741A Alt.4.

4000

75

300000

... More
Preparation and fixing of location box board on 03 mm ACP sheet with size 12 x 18 size A3 for location box including pasting of printed/ painted vinyl sheet and lamination (printing/painting of location detail on vinyl sheet covered in schedule item separately).

12

239

2876.76

... More
Switch Plate lubricant Cenolube 100 or better NLGI 1.5 GRADE Black colored Grease which should be non asphaltic Non bituminous blend of very heavy oils, inert thickeners and lubricating solids coupled with molybdenum disulfide and graphite with no traces of chlorinated solvent such as 1,1,1 trichloroethane which are flammable and harmful to the environment. Should have a blend of select high viscosity index solvent refined severely hydrofinished paraffin base oils and synthetic base fluids. It should incorporate solid lubricants &additives to fill & lubricate micronized asperities to provide & form many films on the contact surfaces to prevent metal-to-metal contact. It shall be designed to be hand applied providing a tough adherent Lubricant film with Tacky semi-dry finish reducing contaminant adhesion. It should act as a SURFACE POLISH with high shear stability and UV protection. The grease Should Not form a difficult to remove thick DRY film which 14 requires scrapping & solvent cleaning of Switch Plate specially before reapplication The grease should Not need Cleaning or scrapping before Reapplication. The Grease should be formulated for tropical climates and should not contain pour point depressants and should Not be too thin. The grease shall be Resistant to water wash off & dilution, water insoluble, non-melt and chemically resistant to exposed environment. The grease shall be formulated with Extreme Pressure additives, rust and corrosion inhibitors, anti-wear additives to protect external surfaces against the harsh elements in severe climates, thus reducing rust binding and adhesive wear on switch plates. Water washout- Excellent (ASTMD1264) <1% ASTM D4049 -water Spray Resistance (simulating rain).Minimal grease loss (<10%) under high-pressure water spray.(ASTM G154 )- UV Resistance (Fluorescent UV Light Exposure- Gloss retention of 90% or higher after 1,000-2,000 hours of exposure. Four Ball Weld LOAD (ASTM- D2596) >600 Kg, Copper corrosion 24 hrs. @ 100c (ASTM D 4048) 1a -1b,(ASTM D4289) - Compatibility with Rubber SealsMinimal swelling (<5% change in volume). No softening or hardening (<10% change in hardness). No cracking or surface degradation. packing /25kg Drum.

100

4950

495000

... More
Supply of 35 Sqmm maulti strand signle core PVC insualtedcopper cable for connecting earth bus bar to earth electrode.

100

422

42252

... More
Disconnect Terminal Block, Screw less type, as per RDSO Spec.No. RDSO/SPN/189/2004. With the latest amendments. Supply of Carrier Railsfor above 35mm x 7.5mm, 1mm/0.039 in thickness un-slotted type as per siterequirement.

70

113

7971.6

... More
Supply of Copper Lugs 16 to 25 Sqmm for power cable or as per instructions of Engineer In-Charge.

3000

9

28650

... More
Shifting of existing half location boxes coming in the alignment of new line. The work includes losing & removal of soil around location boxes by excavating soil around foundation, making 25 of pit for shifting of location box horizontally opposite to railway This includes loosing of existing cable coils without any damage. The excavated soil shall be back filled after shifting of Location Boxes. Location box shall be shifted by push method with the help of jacks or by crane by contractors own expenditure under instructions of engineer in-charge at site. The work may affect train working hence the work shall be done as per margin only or during traffic block only.

4

3379

13518.88

... More
Supply of final Cable Route Plan as per laid cable duly measured at every 30m clearly indicating distance of laid cable from fixed point of reference & indicating all track crossings and tail cables in original tracing along with Auto CAD in Pen Drive and Six set copies after approval.

2

1580

3160

... More
Offset brackets for Main Signal, made of tubular steel, outer diameter 140 mm, thickness of pipe 4.5 mm. horizontal length of pipe 545 mm & vertical length of pipe 324 mm with fixing arrangement on Main Signal post as per Drawing No SW/554/G/R.

4

4439

17757.12

... More
As and when required by the Engineer in charge arranging /providing of labors for 4 various safety related works such as protection of track etc. with contractor's T&P, equipment,hand signal flags, spanners,hammers, etc. as per specification special conditionsand detailed scope of work as furnished in the tender and directed by the engineer incharge.

120

649

77965.2

... More
Shifting of existing full location boxes coming in the alignment of new line. The work includes losing & removal of soil around location boxes by excavating soil around foundation, making 24 of pit for shifting of location box horizontally opposite to railway track up to 0.5 to 1.0 mtr. This includes loosing of existing cable coils without any damage. The excavated soil shall be back filled after shifting of Location Boxes. Location box shall be shifted by push method with the help of jacks or by crane by contractors own expenditure under instructions of engineer in-charge at site. The work may affect train working hence the work shall be done as per margin only or during traffic block only.

4

4369

17479.72

... More
- Maintenance Free Earth Electrode of length 3m, including supply of 3 bags of Earth enhancement material for earthling (10KGs /bag) for each electrode & other accessories as per Drg. No. SDO / RDSO/ E&B/001 and RDSO Spec No. RDSO / SPN/197/2008.

40

10403

416123.2

... More
High density polyethylene pipes (HDPE) of 110 mm/125 mm outer Dia, 10 mm wall thickness, along with one coupler for every 6 Mtr. As per spec. No. Is 4984:2016 with latest amendments and material grade: PE 80.

200

701

140200

... More
Digging of trench 1.2 M deep from rail flange/ road level and, 0.3 Mtr to 0.6 Mtr wide 37 and back filling after placing of DWC/ RCC/GI pipe. (Placing of DWC/RCC/GI pipe covered separately).The ballast disturbed be screened and dressed as required by Engineer-in-charge or his representatives and road tarred immediately. For track crossing, Drg. No.CSTE/3644 Pg.7 of 11 and for Road Crossing, Drg. No. CSTE/3644 Pg. 5 of 11 are to be followed.

50

873

43696.5

... More
Supply of Digital Insulation Tester 100V/250V/500V range of Model Rish insu 20 Make :RISHABH or MECO or similar.

4

8240

32961.6

... More
Digital low current clamp meter to measure current leaks (parasitic draw down to 1 18 mA) and electric loads from 1mA to 100 Amp AC/DC, Voltages from 0 to 600V AC/DC, small jaw size to measure current in signalling circuit, 4 digit display. Make -Fluke, GTC/KEW, Scope or superior with better specification as mentioned with all accessories like test lead, batteries and carrying case, sample may be got approved from consignee before supply.

4

18194

72777.36

... More
Skilled man power to be provided by contractor for Engg. JCBs working to provide marking & supervisory work for the S&T cables during digging work by JCB's and repairing /restoring/jointing of cables, if damaged Cables & Joints Material will be provided by railway. While 5 Chuna marking will be done by his/her Chuna will provided by contractor information for deputing skilled man power for above work will be provided by Railway Engineer incharge before 24 hours from commencement of digging by JCBs. They will check cables route by Cable route tracer and will do chuna marking and will show the cables (on rough sketch) available in a small length approximate 50-100 meters of digging. Note: Minimum two man will be provided at a time including Cable jointer, they will stay whole time during JCB digging work. (The CV to be got approved by Railway).

120

707

84873.6

... More
Canon A3, A4 and Legal Colour Laser Computer Printer cum scanner of reputed make as per technical specification. Model may be got apprvoed from Railway in-charge before supply of material.

2

215099

430198

... More
Hand Operated Hydraulic crimping tool with die sets of capacityfrom 16 sq.mm to 400 Sq.mm and carry bag for transportation ACCEPTEDMAKE/BRAND ? Voltz and similar( Warranty Period : Upto 30 months from thedate of supply)

4

5935

23741.6

... More
Fabrication and fixing of SMC sheet in location box by providing all fixtures as per 22 Railway Drawing including fixing of PVC coated string rods at the back side for cable support with contractor's own materials. The work shall be done as per Drg and arrangement similar to SK 783-1/2. With latest alterations & as per instructions of Rly engineer at site. Note: SMC sheet will be taken in place of phenolic laminated sheet. Half Case

4

777

3111.12

... More
Supply and fixing of polyolefin cable channel (Injection Moulded Plastic cable Duct) of size width 100/200 mm, height 155/230 internal/external, length 1 meter produced of polyolefin with 35 fire, protection class K-1 in accordance with DIN 53438 part all for laying signaling/telecom cables, channel attachable to each other with male female swallowtail connectors and having suitable detachable cover including supply of all fixing materials like Brackets,etc. , as per RDSO STS/E/cable laying Precise Vol-IV and as per technical specifications.

1000

1900

1900080

... More
Supply of SS 304 Troughing with cover of size 150x300x 2.5 mtrs. long and 1.0 mm Thk. Along with fixing clamp and necessary Hardware.

50

4318

215940

... More
Preparation of Cable Route Plan of buried S & T Cables using Radio Detector 8200 GS 6 or Similar model GPS Model and DGPS for Per Trench per Km.For existing cables as per the instruction of Engineer in-charge. Submission of report in KMZ file format, Soft Copy Only. In Yard Section (Per trench KM consider as Km)

16

53987

863792

... More
Excavation and Casting of Apparatus Case foundation with contractor's own materials 18 including cement and anchor bolts of standard size. The required scaffolding Ferma etc. for Casting of foundation will have to be brought by the contractor at his own cost. Half Case as per Drg No SK 747or CSTE/5074 or SSLocation.

4

5487

21951.44

... More
Double Walled Corrugated (DWC) HDPE Pipe with associated collars etc. as per RDSO Specification No. RDSO/SPN/204/2011 or latest anti-rodent & anti-oxidant and non-flame propagating type in 6 meters straight length and of size 120 mm outer die,& 103.5 mm inner dia. . One of the 55 following coupling arrangements should also be supplied with each pipe as per the site requirement. 1) Suitable snap fit coupler with rubber 'O-Ring 2) Spacers 3) Tees 4) Bend, 5) End-cap (The total quantity of above items is equal to no. of pipes supplied.) DWC pipe shall be marked at every 1 mtr length in such a way that manufacturer's name, vender name and year of manufacture can be easily identified. Color -Bright Orange; Min Weight = 4kg. Test Check by Consignee & Sample check by JAG officer.

20

1912

38244

... More
Erection of Position Light Shunt signal with Base, Post, and Signal unit. Wiring & Fixing of Number Plate .The work shall be done as per instructions of Rly engineer at site.

-

-

13

... More
Supply of Copper Bus Bar 300 x 25 x 6 mm MEEB.

-

-

50

... More
PVC tube for bootleg outside dia 15mm, inside dia 11mm thickness 2 mm 50 mtrs each coilor as per instructions of Engineer In-Charge.

1000

8

8620

... More
Disconnect Terminal Block, Screw less type, 4-wire front entry (Two in-put & Two out- 43 put) The color will be decided by Engineer - in - Charge. (Preferably In Blue, Red & Grey Colors in the ratio of 1:2:3). as per RDSO Spec. No. RDSO/SPN/189/2004. With latest amendments. Note: Make to be approved by Railway before supply

400

11

4428

... More
Horizontal direction drilling/boring without damage of surface road using Auger Machine. The bore shall be 150 mm Dia & shall be done at the depth of minimum 1200 mm from the 41 ground level. The ground level shall be considered ignoring the bank height of the bank of the road. The length of the bore shall be minimum 4 Mtr long. The HDD with or without HDPE pipe as per direction of Engineer In charge. Note: HDPE pipe supply is taken as separate item. This item also includes cable laying (HDD boring).

200

1187

237570

... More
IS 13410: Glass Reinforced Polyester Sheet Moulding Compounds (SMC) Size of Sheet : 1000x1000x8

12

5388

64664.04

... More
Main LED Signal lighting unit110v ac for Shunt Signal in railway signaling as perRDSO/SPN/153/2011 (Rev. 4.1) or latest.

10

4935

49353.9

... More
Point insulation Complete set as per RDSO Specification IRS: S-40/84 for Switch racket, Split-Stretcher bar & Gauge tie plates (52 Kg/60Kg as per site requirement)

80

1345

107674.4

... More
Main LED signal lighting unit working on 110v ac as per RDSOSpecn. No. RDSO/SPN/199/2010rev.1.1 retrofit table in existingCLS housing (sa23002, s23024/m) Yellow Aspect.

8

7441

59530.4

... More
Supply Color Light Signal Accessories.1. CI Base (As per IRS S-10 & RDSO Drg. No. 28 2011/M With latest assembly).2. Pinnacle.3. Ladder Assembly, as per RDSO Drg. No. SA-23156, with Base, Ladder Guards, Platform, Front Maintenance Platform, MS Supporting bracket to Support Ladder.4. Signal Front Staging Complete Assembly for CLS Unit.5.Signal back staging as per extent WR Practice.

4

3251

13005.32

... More
Fixing of ARA Terminals /Screw less connectors and fuse blocks on phenolic laminated sheets and fixing by stainless steel/brass nuts & bolts. This includes provision of two additional holes on the board on either side for cable conductor entry.

4000

22

91000

... More
Fabrication and fixing of SMC sheet in location box by providing all fixtures as per 21 Railway Drawing including fixing of PVC coated string rods at the back side for cable support with contractor's own materials. The work shall be done as per Drg and arrangement similar to SK 783-1/2. With latest alterations & as per instructions of Rly engineer at site. Note: SMC sheet will be taken in place of phenolic laminated sheet. Single Case

8

2445

19562.88

... More
Professional AC/DC clamp meter 3 3⁄4 digit, true RMS measurement, For Measurement 19 of DC/AC currents up to 1000A, Voltage up to 600V, resistance up to 40 M, and frequency up to 1 MHz with a set of leads & carrying case. Model - DCM39A or equivalent/ higher make Motwane /Stanley /Fluke/ Megger.

4

12853

51414.36

... More
Fabrication and fixing of 'A' Marker (Drg No. CSTE/6180), 'AG' Marker (Drg No. 15 CSTE/6181), 'P' Marker (Drg No. CSTE/6182), Arrow Marker (Drg No. CSTE/6183), 'G' Marker (Drg No. CSTE/6184), 'C' Marker (Drg No. CSTE/6185). Marker disk on signals as per standard practice All material required for this work shall be supplied by Contractor.

20

1280

25616.4

... More
Releasing of Old channel & Troughing & Installation of SS Troughing with cover on bridge

50

649

32450

... More
Supply of Nylon Insulation for Thick Web point machine, consist of Insulating. (1) plate- 02 Nos . as per RDSO Drg. No-S-34041(2) Nylon Insulation bush-8 Nos , as per RDSO Drg. No- (a) S32199-04 Nos . (b) S-8813-04 Nos , (3) Nylon Insulation Washer 08 Nos, as per RDSO Drg. No. (a) S8640/1-04 Nos . (b) S-8640- 04 Nos. 2) Through rod Insulation = 1 no Bush(RDSO Drg No. CSE8640/1, 2 nos Washers (CSE8640/2) 3) Lock slideInsulation -2 nos Bushes (RDSO Drg No- CSE 15 8640/A) 4 nos Washers (RDSODrg No. CSE-8640/1). 4) Detection slide insulation =2 nos Bushes (RDSO Drgno. 8641/A), 4 nos Washers (RDSO Drg No-8640/1). 5) SSD Insulation Rod =1no. Plate (RDSO Drg No S325/M), 2 nos . Bushes (RDSO Drg No-T10372), 4nos. Washers (RDSO Drg No T- 10371). 6) SSD Insulation in Rail 1 no . Washer(RDSO Drg No washer : S8640) 1 no Bush (RDSO Drg No S8641/A) 7) Pbracket Insulation :- Insulation Plate 01 (RH) RDSO Drg No: S3265 Insulation Plate = 01 No (LH) RDSO Drg no. S3266 , Insulation Bushes=04 nos. RDSO Drgno S23199 Insulation Washer : 04 nos . RDSO Drg no. S8640.

20

995

19918.4

... More
Supply of Copper strip of 25 x 2mm for interconnectiing of earth pits

-

-

51

... More
Supply of Modular Location Box as perWR CSTE Drg No. 6285 Modular Type SS304 Full 40 Location Box. It includes Angleframe Relay frame fixture , earthing Rod, Drawing Board, Glass ReinforcedPolyester Sheet Moulding Compoundssheet for fixing ARA terminal, Lock etc.as per WR CSTE Drg No. 6285.Manufacturer's certificate in regard tograde of stainless steel and test reportshall be submitted at the time of supply.

8

87452

699618.64

... More
Drill bits 7.2 mm or as as per instructions of Engineer In-Charge.

-

-

3

... More
Excavation and Casting of foundation for Shunt Signal as per Drg. No. CSTE/6090 with 12 Contractor's own materials including Cement and Anchor Bolts of Standard Size. The required scaffolding, Ferma etc. for Casting of foundation will have to be brought by the Contractor at his own cost.

4

6139

24559.04

... More
Terminal Bank Assembly complete, 855032009-S as per RDSO, approved CG Drg. No.CPME-1124.

20

1963

39270.4

... More
Exothermic welding for any outdoor Work as per instructions of site incharge

-

-

28

... More
Installation of Apparatus Cases with miniature 'E' type lock on CC foundation. This includes filling of location foundations with river bed sand and plastering on top of the sand. 'E' Type lock will be provided by Railway. Single Case

8

1076

8610.32

... More
Supply of Signalling Rapid Joint UV resistance cable jointing system with two half 46 separated enclosure tapered at both ends filled with cross linked polymer and highly robust insulating plastic case class -2 joint . The joint shall be as per RDSO draft specs no. RDSO/SPN/TC/101/2012, the jointing kit suitable for signalling cable Size 6 x 1.5, 12 x 1.5, 19 x 1.5 , 30 x 1.5 mm2. Note: The joint made by rapid jointing kit for signalling cable will be temporary.

4

11200

44800

... More
Cement concrete work for miscellaneous items in the ratio 1: 3: 6. Item includes excavation, ramming, curing and plastering with cement & sand mixture (aggregate not exceeding 3.8 cm.) (Aggregate cement & sand to be supplied by the contractor).

10

6259

62590

... More
Main LED Signal lighting unit working on 110v ac as per RDSOSpecn. No. RDSO/SPN/199/2010 rev.1.1 retrofit table in existing CLS housing (sa23002, s23024/m) GREEN Aspect.

4

8496

33986.6

... More
Erection of CLS Post with base and signal unit on top or on OFF set Bracket, fixing of front and back staging, ladder and guards with contractor's own brackets and fixing materials. This also includes erection of auxiliary signals like calling on, shunt signal if any... The work shall be done 11 as per instructions of Rly engineer at site. It also includes provision & fixing of maintenance platform as per design given by Engineer -In-Charge at site. It also includes supply of padlock for signal units and cable termination box. X' arms to be provided by the contractor till the signals are introduced. The Item includes cutting of Signal post if required by Site In charge. 2/3/4 aspect signal unit mounted directly on signal post.

4

8338

33354.96

... More
Cutting of Hard rock in trenches /Preparation of cable way/Chase 150mm wide at the39 bottom and 300 mm deep in hard rock (Drg prepared by contactor & approved by Engineer In charge) for laying of S&T cables where minimum required depth not possible & which is verified and agreed by Engineer In charge of the work or his representative shall be made as per Drg. No RE/S&T/ALD/SK/301/85. Refilling of the same with concrete mixture of 1:3:6 from top of the cable way/ chase. Payment of concrete will be made separately through a separate item in the schedule of work.

40

438

17549.2

... More
Supply and Installation of White Zink plated MS channel of size 100x50x1.2mtr.long along with fixing Hardware.

50

1687

84370

... More
Maintenance of Track mounted equipments like S&T fitting on turn outs including different activities during BCM/TTM/TRR works as follows:- Specially opening and refixing of DC-TC jumpers/AFTC jumpers / Axle counter, transducers during different Engg. works Opening of DC-TC /AFTC jumpers /axle counter transducers digging work from rail to TLJB /TMU /0 bond /location is 3 required to be done as per site requirement also after refixing of DC-TC /AFTC jumpers /Axle counter transducers needs to be buried in proper depth. It includes drilling hole in rail as per site requirement. The team to be provided for this work should comprise of : Fitter- 1 Nos., Blacksmith 1 Nos. Mason/Carpenter- 1 No. and Helpers-5 Nos. also it include any work of EOLB or sliding boom and earthing arrangement of Signalling gears. Any other work as per instruction of Railway Engineer. All T&P & Jigs required to execute the work will be supplied by the contractor. (Per Day per team consider as Day)

120

6912

829536

... More
Supply & installation of MS Flat Plate Strip (Specification no. 226 STD or latest 35 mm x 6 mm thick for earth connection to Signal post, L/Box etc

2000

169

339400



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.