Know all about the latest MP tenders along with the tender details and downloadable document on BidAssist. Here, on this page, we shall help you search for every MPtender posted on the official website of mptenders.gov.in according to authority, district, etc. Be it an irrigation tender or MP PWD tender, and we will tell you how to bid for these and more.
Raja Ramanna Centre For Advanced Technology - RRCAT Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date4 May 2023
Closing Date25 May 2023
Tender Amount₹ 90,00,000
Costs
EMD
₹ 1,80,000Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2023_RRCAT_751861_1Tender No
RRCAT/E/2023/10 Dated 01.05.2023Tender Authority
Raja Ramanna Centre For Advanced Technology ViewPurchaser Address
-Website
http://eprocure.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Supply, Installation, Testing & Commissioning of indoor, commercial, decorative, surface/suspended (conduit) mounted, high efficiency LED linear luminaire with powder coated extruded Aluminium / steel housing with nominal efficacy ≥ 120 lm/W and nominal luminous output as 3900 lm Colour tempreture: 5700/6500 K, Beam angle: 120°, PF: 0.9 (Min.), THD: 10%, IP: 20, CRI: ≥ 80, Surge Protection: ≥ 2.5 kV, Life Class: L70B50 @ 50 K hrs., Surge Protection: ≥ 4 kV, Optics: High quality polycarbonate diffuser complete with all accessories, driver & all required fixing accessories & hardware etc.
Note: 1) The normal performance (electrical & mechnical) of the luminaires is to be GURANTEED for a period of 5 Years.
2) Additional security deposit amount @ 10% of total value of the item shall be withheld by the department for a peroid of 5 years from the date of completion of work.
165
-
-
... More
3Cx2.5 sq mm, Copper, armoured power cable
30
-
-
... More
4Cx25/16/10 sq. mm Aluminium / Copper conductor
300
-
-
... More
Supply and Installation of 25 mm size ERW MS conduit pipes to be installed inside the RCC slab/bricks wall/on surface/Metallic structure along with bends, junction boxes, metallic boxes, sadle, clamp, binding wire & all required materials. The jointing of two section of conduit shall be done using threaded section of conduit. For mounting of conduit, any cutting/chasing & repairing in the RCC/brick wall shall be part of the work.
700
-
-
... More
Only Installation, Testing & Commissioning of 1100 V, Aluminium/Copper conductor, PVC/XLPE insulated, armoured/unarmoured power cables of following sizes in trench/hume pipes/cable trays/wall. All required fixing material are included in this item:
-
-
-
... More
Surface/suspended/recessed mounted indoor/outdoor luminaires of all types from existing installation (wall/ceiling/all type false ceiling/welded on EP etc) along with removal of associated junction box, ceiling rose, wiring, end terminations & cabling etc..
1640
-
-
... More
Incomer: 32A, DP MCB (10 kA)
Outgoings: Analog Timer (24 hours with 2 Segment) - 1 No.
25 A, DP, contactor- 2 Nos.
3
-
-
... More
Supply, pulling and end termination of FRLS PVC insulated multistranded/flexible copper wire (Red/Yellow/Blue/Black/Green) of following size in concealed/surface mounted MS conduit pipes along with supply of all required material/hardware.
-
-
-
... More
Supply and Installation of following type & size earthing strip on wall/metallic structure/cable tray/ in the ground along with all required material (insulator/fixing support etc), hardware etc.:
-
-
-
... More
Incomer: 63A FP RCBO (10 kA) with 30 mA senstivity
Outgoing: 10/16/20/25/32 A SP MCB- 36 Nos.
12 way/phase, VTPN DB
6
-
-
... More
Supply, Installation, Testing & Commissioning of enegry efficient, T8 LED Tube lamp having min output: 4000 lumen, nominal wattage as 30 watt, light colour: 865, beam angle: 160° on existing all types conventional linear luminaires installed on wall/ceiling/all type of false ceiling. This item includes supply & installtion of suitable size FRLS PVC grey/white wiring, wiring connector & connecting holder required for installing T8 LED tube lamp in conventional linear lumianires. This also includes removal of existing lamps, all types of ballasts, starter & associated wiring etc. from existing luminaires and storing it with in 2.5 km radius. This item also includes all other required material/hardware & scaffoldings/ladder/atcker etc. required for proper installation at site.
Note: 1) The normal performance (electrical & mechnical) of the luminaires is to be GURANTEED for a period of 5 Years.
2) Additional security deposit amount @ 10% of total value of the item shall be withheld by the department for a peroid of 5 years from the date of completion of work.
700
-
-
... More
Supply, Installation, Testing & Commissioning of outdoor, surface mounted, high efficiency LED flood light luminaire with Aluminium die cast housing with nominal luminous output as 6800 lm and nominal efficacy as 135 lm/W, Colour tempreture: 4000 K, pf: 0.9 (Min.), THD: 10 %, Surge Protection: ≥ 4 kV, Optical Cover: Polycarbonate, IP: 66, CRI: ≥ 70 complete with all accessories, driver & all required fixing accessories & hardware etc.
Note: 1) The normal performance (electrical & mechnical) of the luminaires is to be GURANTEED for a period of 5 Years.
2) Additional security deposit amount @ 10% of total value of the item shall be withheld by the department for a peroid of 5 years from the date of completion of work.
20
-
-
... More
Supply, Installation, Testing & Commissioning of End termination of Aluminium/Copper, armoured power cables of following sizes with double compression gland:
-
-
-
... More
Supply, Installation, Testing & Commissioning of indoor, recess mounted LED type downlighter meeting the following specifications:
Luminous flux: 1600 lm ± 10% , Efficacy (Min.): 100 lm/W, Colour tempreture: 5700/6500 K, Wide, IP: 20, PF: 0.9 (min) , THD: 10%, CRI: ≥ 80, Surge Protection: ≥ 2.5 kV, Life Class: L70B50 @ 50 K hrs., low ripple, Optics: High quality diffuser.
Note: 1) The normal performance (electrical & mechnical) of the luminaires is to be GURANTEED for a period of 5 Years.
2) Additional security deposit amount @ 10% of total value of the item shall be withheld by the department for a peroid of 5 years from the date of completion of work.
85
-
-
... More
Supply, Installation, Testing & Commissioning of indoor, recessed, bottom openable, IP: 54, 2"x2", high efficiency robust LED clean room luminaire with metallic powder coated/ die cast aluminium housing with luminous output as 3500 lm and nominal efficacy ≥ 100 lm/W, Colour tempreture: 6500/5700/4000 K, Beam angle: 120°, PF: 0.9 (Min.), THD: 10%, CRI: ≥ 80, Surge Protection: ≥ 2.5 kV, Life Class: L70B50 @ 50 K hrs., Surge Protection: ≥ 4 kV, Optics: High quality diffuser complete with all accessories, driver & all required fixing accessories & hardware etc.
Note: 1) The normal performance (electrical & mechnical) of the luminaires is to be GURANTEED for a period of 5 Years.
2) Additional security deposit amount @ 10% of total value of the item shall be withheld by the department for a peroid of 5 years from the date of completion of work.
27
-
-
... More
1.5 sq. mm
1500
-
-
... More
Supply, Installation, Testing & Commissioning of 1100V, 3Cx2.5 Sqmm, Copper stranded, XLPE insulated, FRLS PVC outer sheathed, armoured power cable in trench/hume pipes/cable trays/wall/Ms support with all required hardware & accessories.
750
-
-
... More
Supply, Installation, Testing & Commissioning of indoor, surface mounted LED type downlighter meeting the following specifications:
Luminous output: 1600 lm ± 10 %, Efficacy (Min.): 100 lm/W, Colour tempreture: 5700/6500 K, Wide, IP: 20, PF: 0.9 (Min.), THD: 10%, CRI: ≥ 80, Surge Protection: ≥ 2.5 kV, Life Class: L70B50 @ 50 K hrs., Optics: High quality diffuser.
Note: 1) The normal performance (electrical & mechnical) of the luminaires is to be GURANTEED for a period of 5 Years.
2) Additional security deposit amount @ 10% of total value of the item shall be withheld by the department for a peroid of 5 years from the date of completion of work.
30
-
-
... More
Earthing Copper strip (50X6/32X6/25X3) / wire including required hardware for installation.
35
-
-
... More
Dismantling of following existing electrical system/equipment/item/accessories etc and storing within the 2.5 km radius. All required hardware/material & ladder/scaffoldings/arrangements are included in the item & in the scope of the contractor:
-
-
-
... More
Supply, Installation, Testing & Commissioning of indoor, decorative, high efficacy, recess mounted LED type linear (4' feet) meeting the following specifications:
Housing: Powder coated CRCA / extruded Aluminium, Driver type: External, IP: 20, Luminous Output (Nominal): 2600 lm, Efficacy (Min.): 100 lm/W, CCT: 5700/6500 K, LED life with LM70: 50,000 hours, PF (Min.): 0.9, THD: 10%, CRI: ≥ 80, Surge Protection: ≥ 2.5 kV, Optics: High quality diffuser, Operation Cycle: 24x7. This luminaire shall replace existing recess mounted 1x36W conventional flourecent lamp based luminaires mounted in Gypsum Board false ceiling at height of around 3.5 meter. The cut-out dimensions of new LED luminaires for recessed mounting shall be matched with the existing cut-out in the Gypsum Board false-ceiling. MS/Die cast Aluminium powder coated frame may be provided along with new LED luminaires to accomodate the luminaire in the existing false ceiling cut-out subject to site requirement & approval of Engineer-in-charge.The colour of the metallic frame shall also be matched with LED luminaire housing. All this required arrangements to accomodate the new LED luminaire in the exising false ceiling cut-out shall be in the scope of contractor. The required ladder/stacker/any other arrangement for working safely at 6 meter height for whole installation work shall be in the scope of contractor. The nominal size of existing cut out in Gypsum Board false ceiling is approximately 1230 (L) x 110 (W) mm. Note: 1) The normal performance (electrical & mechnical) of the luminaires is to be GURANTEED for a period of 5 Years.
2) Additional Security deposit amount @ 10% of total value of the item shall be withheld by the department for a peroid of 5 years from the date of completion of work.
95
-
-
... More
Supply, Installation, Testing & Commissioning of MS prefabricated and powder coated lighting distribution board with all switchgear and accessories having IP42 protection class having following details:
-
-
-
... More
2.5 sq. mm
2000
-
-
... More
G.I earth strips (50X6/32X6/25X3) / wire including required hardware for installation
100
-
-
... More
Supply, Installation, Testing & Commissioning of indoor, recess mounted LED type downlighter meeting the following specifications:
Luminous output: 1500 lm ± 10% , Efficacy (Min.) : 100 lm/W, Colour tempreture: 5700/6500K, IP: 20, PF: 0.9 (Min.) , THD: 10%, CRI: ≥ 80, Surge Protection: ≥ 2.5 kV, Life Class: L70B50 @ 50 K hrs., Optics: High quality diffuser. This luminaire shall be replaced with 2x11W conventional fluorescent lamp based lumianires which includes disconnection of wiring, dismantling of luminaire etc. and restoring the existing luminaires within 2.5 km distance. The existing luminaires are mounted in false ceiling at height of around 3 meter. The cut-out dimensions of new LED luminaires shall be matched with the existing cut-out in the false-ceiling, hence modication work shall be required in the false ceiling for mounting of new LED luminaires. Modification work in false ceiling with all required arrangements shall be in the scope of contractor subject to site requirement & approval of Engineer-in-charge.
Note: 1) The normal performance (electrical & mechnical) of the luminaires is to be GURANTEED for a period of 5 Years.
2) Additional security deposit amount @ 10% of total value of the item shall be withheld by the department for a peroid of 5 years from the date of completion of work.
80
-
-
... More
3/4Cx6/4/2.5/1.5 sq. mm Copper/Aluminium conductor power cable with end terminations
300
-
-
... More
Supply, Installation, Testing & Commissioning of indoor, decorative, high efficacy, recess mounted LED type linear (4' feet) meeting the following specifications:
Housing: Powder coated CRCA / extruded Aluminium, Driver type: External, IP: 20, Luminous Output (Nominal): 5000 lm, Efficacy (Min.): 100 lm/W, CCT: 5700/6500 K, LED life with LM70: 50,000 hours, PF (Min.): 0.9, THD: 10%, CRI: ≥ 80, Surge Protection: ≥ 2.5 kV, Optics: High quality diffuser, Operation Cycle: 24x7. This luminaire shall replace existing recess mounted 2x36W conventional flourecent lamp based luminaires mounted in Gypsum Board false ceiling at height of around 6 meter. The cut-out dimensions of new LED luminaires for recessed mounting shall be matched with the existing cut-out in the Gypsum Board false-ceiling. MS/Die cast Aluminium power coated frame may be provided along with new LED luminaires to accomodate the luminaire in the existing false ceiling cut-out subject to site requirement & approval of Engineer-in-charge. The colour of the metallic frame shall also be matched with LED luminaire housing. All this required arrangements to accomodate the new LED luminaire in the existing false ceiling cut-out shall be in the scope of contractor. The required ladder/stacker/any other arrangement for working safely at 6 meter height for whole installation work shall be in the scope of contractor. The nominal size of existing cut out in Gypsum Board false ceiling is approximately 1230 (L) x 170 (W) mm. Note: 1) The normal performance (electrical & mechnical) of the luminaires is to be GURANTEED for a period of 5 Years.
2) Additional security deposit amount @ 10% of total value of the item shall be withheld by the department for a peroid of 5 years from the date of completion of work.
790
-
-
... More
Concealed/surface mounted distribution boards of all types & size along with removal of all switchgears (MCCB/SFU/MCB/RCBO/MCB/FUSE etc) & associated wiring, cabling, end terminations & other associated accessories.
6
-
-