Rail Coach Factory Tender

View complete overview of RCF Tender

Rail Coach Factory - RCF Tender

Goods
Metals and Non-Metals
Ireps
NA
Opening Date19 Nov 2024
Closing Date19 Dec 2024
Tender AmountRefer Documents 
This is an estimated amount, exact amount may vary.
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
PL Code : 33520859 STEEL SHEET OF SIZE 12X2500X6300MM., as per Drawing: DIN EN 10025-5 S355 J2W+ N. SPECIFICATION FOR ULTRASONIC TESTING OF STEEL PLATES SHALL BE ASTM-A-578(REAPPROVED 2 001). THE ACCEPTANCE STANDARD SHALL BE "LEVEL B" (PARA 8 OF ASTM-A-578) WITH FREQUENCY 1 00% (ALL THE PLATES SHALL BE UT TESTING),SCANNING SHALL BE CONTINUOUS OVER 100% OF PLAT E SURFACE., Packing Instruction: MILD / CORTEN/ EN STEEL COILS, SHEETS AND PLATES:- (A) MILD, EN AND CORTEN STEEL SHEETS IN COIL FORM. THE COIL SHALL BE PROTECTED IN REASONABLY GOOD C ONDITION TO WITHSTAND NORMAL HANDLING HAZARD DURING TRANSIT WITH THE FOLLOWING PRO VISION AS THE BAREST MINIMUM: I) THE WHOLE COIL SHOULD BE WRAPPED WITH DOUBLE LAYER OF WATER PROOF PAPER AND A BIODEGRADEABLE PLASTIC SHEET OF SUITABLE THICKNESS. II) THE INNE R EDGE OF THE COIL SHOULD BE PROTECTED BY GI RING FOLLOWED BY ANOTHER IRON RING. III) OU TER EDGE OF THE COIL SHOULD BE WRAPPED WITH GI RING. IV) COIL SHOULD BE SECURELY STRAPPE D WITH MINIUM 5 STEEL BANDS THROUGH THE EYES OF THE COIL AND MINIUM 3 STEEL BANDS ON T HE CIRCUMFERENCE OF THE EYE. V) HOT ROLLED COILS SHALL BE SUPPLIED WITH RUST PREVENTIVE OIL COATING ON THE OUTER LAYER, INNER LAYER AND ON THE BOTH EDGES. VI) COILS PROCESSED T HROUGH PICKLING AND OR SKIN PASSING OR COLD ROLLING OF THICKNESS UPTO 2MM SHALL BE PR OTECTED AGAINST CORROSION AND RUST BY COATING CORROSION PREVENTIVE FLUID, SOFT FILM, S OLVENT DEPOSITED, WATERDISPLACING TO IS: 1154 . VII) WHOLE COIL SHOULD BE MOUNTED ON WO ODEN BLOCKS FOR EASY LIFTING/ STACKING. VIII) THE SHEETS IN COIL FORM FOR THICKNESS 2MM A ND ABOVE SHALL HAVE: INNER DIA OF COIL 450-800MM OUTER DIA OF COIL 1000-1300MM WEIGHT O F COIL 2.4 - 10 TONNES IX) THE SHEETS IN COIL FORM FOR THICKNESS BELOW 2MM SHALL HAVE: INN ER DIA OF COIL 450-650MM OUTER DIA OF COIL 1000-1300MM WEIGHT OF COIL 5.0 - 10 TONNES. (B) MILD, EN AND CORTEN STEEL PLATES/SHEETS. I) PLATES ABOVE 5MM SHALL BE SUPPLIED WITH REAS ONABLE PACKING WITH METAL STRAPING FOR HANDLING DURING TRANSIT AND STORAGE. II) THE SH EETS/PLATES SHALL BE SUPPLIED IN BUNDLES WITH DOUBLE LAYER OF WATER PROOF PAPER & A BIO DEGRADEABLE PLASTIC SHEET OF SUITABLE THICKNESS AND METAL PROTECTION IN EDGES.ALL THE SHEETS UPTO 2MM THCKNESS SHALL BE PROTECTED AGAINST CORROSION AND RUST BY COATING C ORROSION PREVENTIVE FLUID, SOFT FILM, SOLVENT DEPOSITED, WATERDISPLACING TO IS: 1154 AND ALL THE SHEETS/PLATES ABOVE 2MM SHALL BE PROTECTED AGAINST COROSION & RUST WITH SUITA BLE MINERAL OIL OR OTHER TEMPORARY RUST PREVENTIVE COATING. III) ALL BUNDLES SHALL HAVE A MINIMUM OF 2 HOOPS UPTO 1.2 METER IN LENGTH AND ONE EXTRA HOOP FOR EVERY ADDITIONAL METER. THE BUNDLES SHALL ALSO BE PROVIDED WITH SKID (WOODEN PACKING UNDER NEATH) TO F ACILITATE HANDLING. IV) OPTIMUM WEIGHT OF THE BUNDLE SHOULD BE 2MT+-10%. MECHANICAL D AMANGE & CORROSION DURING TRANSIT IF ANY SHALL BE AT THE COST OF SUPPLIER. [ Warranty P eriod: 30 Months after the date of delivery ] [Quantity Tolerance (+/-): 5 %age , Item Category : Normal , Total PO value variation Permitt ed: Max 8 lacs ] ] Consignee SHELL DEPOT, RCF Punjab 210177.00 Kg Inspection

-

-

-

... More
PL Code : 33521128 STEEL SHEET OF SIZE 20X2500X6400MM., as per Drawing: DIN EN 10025-5 S355 J2W+ N. SPECIIFCATION FOR ULTRASONIC TESTING OF STEEL PLATES SHALL BE ASTM-A-578(REAPPROVED 2 001) WITH FREQUENCY 100% (ALL THE PLATES SHALL BE UT TESTING),SCNANNING SHALL BE CONTIN UOUS OVER 100% OF PLATE SURFACE., Packing Instruction: MILD / CORTEN/ EN STEEL COILS, SHEETS AND PLATES:- (A) MILD, EN AND CORTEN STEEL SHEETS IN COIL FORM. THE COIL SHALL BE PROTECTE D IN REASONABLY GOOD CONDITION TO WITHSTAND NORMAL HANDLING HAZARD DURING TRANSIT WITH THE FOLLOWING PROVISION AS THE BAREST MINIMUM: I) THE WHOLE COIL SHOULD BE WRAPPE D WITH DOUBLE LAYER OF WATER PROOF PAPER AND A BIODEGRADEABLE PLASTIC SHEET OF SUITAB LE THICKNESS. II) THE INNER EDGE OF THE COIL SHOULD BE PROTECTED BY GI RING FOLLOWED BY A NOTHER IRON RING. III) OUTER EDGE OF THE COIL SHOULD BE WRAPPED WITH GI RING. IV) COIL SHO ULD BE SECURELY STRAPPED WITH MINIUM 5 STEEL BANDS THROUGH THE EYES OF THE COIL AND MI NIUM 3 STEEL BANDS ON THE CIRCUMFERENCE OF THE EYE. V) HOT ROLLED COILS SHALL BE SUPPLIE D WITH RUST PREVENTIVE OIL COATING ON THE OUTER LAYER, INNER LAYER AND ON THE BOTH EDG ES. VI) COILS PROCESSED THROUGH PICKLING AND OR SKIN PASSING OR COLD ROLLING OF THICKNES S UPTO 2MM SHALL BE PROTECTED AGAINST CORROSION AND RUST BY COATING CORROSION PREVE NTIVE FLUID, SOFT FILM, SOLVENT DEPOSITED, WATERDISPLACING TO IS: 1154 . VII) WHOLE COIL SH OULD BE MOUNTED ON WOODEN BLOCKS FOR EASY LIFTING/ STACKING. VIII) THE SHEETS IN COIL FO RM FOR THICKNESS 2MM AND ABOVE SHALL HAVE: INNER DIA OF COIL 450-800MM OUTER DIA OF COI L 1000-1300MM WEIGHT OF COIL 2.4 - 10 TONNES IX) THE SHEETS IN COIL FORM FOR THICKNESS BEL OW 2MM SHALL HAVE: INNER DIA OF COIL 450-650MM OUTER DIA OF COIL 1000-1300MM WEIGHT OF COIL 5.0 - 10 TONNES. (B) MILD, EN AND CORTEN STEEL PLATES/SHEETS. I) PLATES ABOVE 5MM SHAL L BE SUPPLIED WITH REASONABLE PACKING WITH METAL STRAPING FOR HANDLING DURING TRANSIT AND STORAGE. II) THE SHEETS/PLATES SHALL BE SUPPLIED IN BUNDLES WITH DOUBLE LAYER OF WAT ER PROOF PAPER & A BIODEGRADEABLE PLASTIC SHEET OF SUITABLE THICKNESS AND METAL PROTEC TION IN EDGES.ALL THE SHEETS UPTO 2MM THCKNESS SHALL BE PROTECTED AGAINST CORROSION A ND RUST BY COATING CORROSION PREVENTIVE FLUID, SOFT FILM, SOLVENT DEPOSITED, WATERDISPL ACING TO IS: 1154 AND ALL THE SHEETS/PLATES ABOVE 2MM SHALL BE PROTECTED AGAINST COROSI ON & RUST WITH SUITABLE MINERAL OIL OR OTHER TEMPORARY RUST PREVENTIVE COATING. III) ALL BUNDLES SHALL HAVE A MINIMUM OF 2 HOOPS UPTO 1.2 METER IN LENGTH AND ONE EXTRA HOOP F OR EVERY ADDITIONAL METER. THE BUNDLES SHALL ALSO BE PROVIDED WITH SKID (WOODEN PACKI NG UNDER NEATH) TO FACILITATE HANDLING. IV) OPTIMUM WEIGHT OF THE BUNDLE SHOULD BE 2MT +-10%. MECHANICAL DAMANGE & CORROSION DURING TRANSIT IF ANY SHALL BE AT THE COST OF SU PPLIER. [ Warranty Period: 30 Months after the date of delivery ] [Quantity Tolerance (+/-): 5 %age , Item Category : Normal , Total PO value variation Permitt ed: Max 8 lacs ] ] Consignee SHELL DEPOT, RCF Punjab 58125.00 Kg Inspection Details Stage Inspection Not Required

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.