General Power Supply Work Of Electrification Of Sick Line Covered Shed, Inspection Pit, Service Buil

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply and erection of MS tubular pole of 11 meter long as per specification, designation no. 410SP54, IS: 2713-1980 (Part I & II).

8

14207

113656

... More
Laying, underground/road/Railway track, recessing in platform /wall along with Rly. Track/in laid 16 RCC/GI pipe as required 1.1 KV grade LT XLPE insulated armoured, aluminium conductor cable including making chase & plastering after laying of cable/digging of cable trench, sand cushioning, protective covering with second class bricks, provision of cable route marker as per Tech. Specfn. including end terminations with Alu. Crimping socket/lugs, testing and commissioning of following sizes :- Above 120 sq. mm.

3000

31

191635.8

... More
Connections with GI strip 300 mm deep in ground / recessing in floor clamping in Trenches of sub- station by grouting clamps manufacture with MS sheet 14 SWG, from earth electrode strip to HT Panel/LT Panel /AMF Panel/ Transformer / DG Set etc. as per approved drawing and technical specification including supply of material of size: 40x5 mm

120

61

15083.59

... More
Design, manufacture, supply, erection, testing & commissioning of 200 KVAR 3 phase Automatic Power Factor Control Panel as per explanatory note & drawing approved by Railways.

1

305046

305046

... More
Supply, Installation, testing and commissioning of following Modular accessories as per explanatory note. Blank plate single as per M/s Crabtree make Code-CQ 000400

30

45

1350

... More
Straight through joint Heat shrinkable type for 120-185 sq.mm 3 core XLPE insulated 11 KV(E) aluminum conductor cable confirming to relevant IS (Latest version) as per technical specification with supply of material including testing and commissioning. Straight through type 120 to 185 sq.mm

4

23718

94872

... More
Supply, Installation, testing and commissioning of following Modular accessories as per explanatory note. Snap switches 16 A single pole as similar to M/s Crabtree make Code-CQ 0000060

20

162

3240

... More
One Job consists of dismantling of one Rail pole / Tubular pole by digging / cutting from the ground 1 level (min 450 MM) including removing of over head conductor, bracket, insulators , earth wire ,guard wire etc. and transport the same from site to the store of SSE(E)/C/MB. Note:- (dismantling will be done in the presence of site supervisor with proper safety arrangement.)

30

1504

45120

... More
Design, Manufacturing, supply fixing testing & commissioning of Single LED type signages of 28 suitable size as per PCEE/NR/121-Elect/PS/2019 (REV.-'4'), dt: 04.11.2019 (Attached) or latest and as per site requirement Note- Static /single sided Board of different size name is required Prior approval of message Colour and size to be taken from competent authority.

300

1330

399000

... More
Supply of Piano type switch as per IS 4949 -1968(latest version) /Bell push as per IS 4794 (Part 2) -1986(latest version)/flush type socket outlet as per IS 1293 -1988(latest version) & installation on the recessed switch box including cutting of phenolic laminated sheet, connection, testing & commissioning as per Tech. Specifications. Piano Type switch 15A (1- way)

106

25

5460.59

... More
Supply, Installation, testing and commissioning of following Modular accessories as per explanatory note. Power sockets with safety shutter 16 A as similar to M/s Crabtree make Code-CQ 000220

20

269

5380

... More
Supply, erection, fixing, testing & commissioning of fresh air Fan size 12" (300 mm) 220Volt.AC.50 Hz ISI marked approved make complete in all respect as per tech. specification/site requirement.

30

1504

45120

... More
Supply and erection of sheet enclosure mad out of 16 SWG MS sheet hylem sheet, locking arrangement consisting of 1x32 DP MCB power coated paint and other connected accessories etc.

20

1504

30080

... More
Supply and laying of HDPE pipe with outer dia 160 mm and inner dia 140 mm as per relevant IS and explanatory note.

2500

1322

3305000

... More
Supply, erection , fixing & commissioning of 1200/1400 mm sweep energy efficient ceiling fan with fan regulator etc. complete in all respect as per site requirement (5 star Rating)

120

1802

216240

... More
Design, manufacture supply, erection, testing & commissioning of wall /Pillar mounted LT Distribution box as per drawing approved by Railway in two compartments: (a) In Ist compartment - (i) One No industrial type Plug socket 63 Amps. (3+E) with cover & chain connected with one No. MCCB 4 Pole, 63 A. 35 KA 42 B/C fixed type magnetic setting (ii) One No industrial type plug socket 32 A. (2+E) with cover & chain connected with one No. 32 A. DP MCB 10 KA B/C (b) In IInd compartment - Aluminium bus bar 300 Amps. for Phase and 150 Amps. for Neutral suitable for operation on 3 Phase 4 Wire 415 Volts AC supply system complete with inter connection with single core, PVC insulated, copper conductor cable 10 Sq. mm. from bus bar to MCCB/MCB & socket including supply testing & commissioning and as per explanatory note.

14

23632

330848

... More
Supply and erection of 5 m high hot dip galvanized octagonal pole with top 70 mm around face bottom 130 mm around face made of 3 mm thick base plate size 200x 200x12 mm complete with appropriate 3 sleeve at the top of the pole for mounting single arm bracket 300 mm long suitable for 45-50 watt LED street light fitting including casting, muffing with cement concrete foundation(1:2:4) painting, earthing and foundation GI Nut bolt of suitable length with washer and smart pack, junction box with single pole MCB & terminal and as per explanatory note. b) Double arm

25

9121

228025

... More
Earthing with 600x600x6 mm thick GI plate earth electrode as per IS 3043 (latest version) to 22 achieve earth resistance less than one ohm, including construction of masonry enclosure with hinged cover plate of cast iron with locking arrangement (Approx. size 600 x 600 mm) on top, watering pipe, connections from earth plate to top with 40x10 mm G.I. strip in 50 mm dia GI pipe class 'B' provision of each plate as per drawing and technical specification.

8

1974

32541

... More
Supply, fixing, testing & commissioning of LED light luminaries 595 X 595 mm size, Tile type, having 37 system wattage 36-45 Watt, CRCA body powder coated, high efficiency milky white PMMA diffuser with no bright spot visible, complete with all mounting arrangement accessories conforming to CEE/NR specification no. PCEE/NR/121-Elect/PS/2019 (REV.-'4'), dt: 04.11.2019 (Attached) or latest.

20

4457

89140

... More
Design, manufacture supply, installation, testing & commissioning of double door timer control 15 panel suitable to operate 3 phase 4 wire 415 Volt AC supply system for automatic switching OFF & ON of all luminaries as per technical specification with following accessories: -MCB (TPN) 63 A, B/C 10 KA-01 No -Timer with CM 40 contactor chargeable cells/battery-1 No. -Toggle switch-1 No.

2

18360

36720

... More
Supply of 150 watt LED based Flood light fitting with all accessories including testing, 18 commissioning and earthing including connections with 2x2.5 sq.mm PVC insulated multi-stranded ISI marked copper conductor cable from Junction Box to fitting as per PCEE/NR/121-Elect/PS/2019 (REV.-'4'), dt: 04.11.2019 (Attached) or latest and as per explanatory note.

60

11980

718800

... More
Fabrication, supply and installation of perforated GCGI Tray of following size including horizontal 22 and vertical bends, redusers, T's, cross members and other accessories duly galvanized and supporting/mounting with pillar/angle structure as well required at site as per explanatory notes. 300mm wide x75mm deepx1.6 mm thick.

800

647

517600

... More
Supply, fixing, testing and commissioning of TPN distribution board 4 way complete with TPN MCCB 63/100 Amps.(FP) adjustable type 01 no.(35 KA) and MCB SP 6-32 Amps.12 Nos.(10 KA) complete in all respect as per site requirement/IE rule & technical specification.

16

10186

162976

... More
Supply, Installation, testing and commissioning of following Modular accessories as per explanatory note. Snap switches 6 A single pole as similar to M/s Crabtree make Code-CQ 000006

100

127

12700

... More
Supply of M.S switch box conforming to IS 5133 (Part - I) - 1969 (latest version) with white Phenolic laminated sheet cover of approved make on front of box with brass screws & cup washers, recessing as per Tech. Specification including earthing. 180x100x60mm deep

30

45

2781.81

... More
Supply, installation, connection and commissioning of 500 KVA outdoor type 11KV/415 Volt delta/Star connected copper wound distribution transformer complete with accessories as per explanatory note including erection, testing and commissioning.

2

796887

1593774

... More
Design, Manufacturing, supply fixing testing &commissioning of Double LED type signages of 27 suitable size as per PCEE/NR/121-Elect/PS/2019 (REV.-'4'), dt: 04.11.2019 (Attached) or latest and as per site requirement Note- Static /single sided Board of different size name is required Prior approval of message Colour and size to be taken from competent authority.

150

1955

293250

... More
Supply and drawing of the following Sizes FRLS PVC insulated multi-stranded copper conductor 32 single core flexible cable conforming to IS 694 ( latest version ) in laid (recessed/Surface) MS/PVC/HDG Conduit pipe for wiring of point wiring/circuit wining/Sub main/Main as required & as per explanatory note including drawing, connection testing and commissioning 1.5 sq. mm.

6000

12

72000

... More
Supply and fixing of MS channel 75x40 mm size and approximate length of 2.6 meter with suitable clamps for securing each type piece of 11 kV and 33 kV outdoor type jointing kits.

12

1814

21768

... More
Supply, erection, testing and commissioning of modular boxes concealed boards with white finish single mounting plate and fixing of switches/plug, sockets, fan regulators and connection to wiring, metal boxes boards are to be concealed in the wall of following sizes 8 Module

10

263

2630

... More
Design & manufacture as per IS 3427/1993 and Supply of 11 KV HT Panel Board 350 MVA 630 Amps. capacity comprising of: 2 Nos. Incoming H.T. Panel complete with motorized 3 pole Vacuum Circuit Breaker conforming to IS 13118 (Latest Version) complete with 110 Volts, AC motor operated mechanism, P.T. 11 KV/110 V. conforming to IS 3156 Part I & II/1992 (Latest Version), double ratio current transformer (100/50/5+5) conforming to IS 2705 Part I to III (Latest Version) digital Ammeter & Voltmeter , numerical type 2 O/C + E/f - 25 IDMT Relay with high set selector switch, clustered LED type indication light and suitable cable end termination box. 2 Nos. Outgoing H.T. Panel complete with motorized 3 pole Vacuum Circuit Breaker conforming to IS 13118 (Latest Version) 110 Volts AC motor operated mechanism, tripping/closing coil ,digital Ammeter, clustered LED indication light double ratio copper wound current transformer( 40/20/5+5) conforming to IS 2705/Pt.I to III (Latest Version), numerical Relays 2 O/C + E/f - IDMT with high, clustered LED type indication light, selector switch and suitable cable end termination box and as per explanatory note & drawing approved by Railway Including erection, testing & commissioning.

1

1278945

1278945

... More
Earthing with 50mm dia GI pipe class 'B', 3 meter long earth electrode as per IS:3043 (Latest Version) to achieve earth resistances less than 5 ohms including construction of masonry enclosures with hinged cover plate of cast iron with locking arrangement (approx. size 400mmx400mm) on top, provision of earth plate, connections from earth electrode to switch gear/pole as per drawing.

80

883

145560.78

... More
Supply of DG set complete with diesel engine, copper wound alternator, battery set, anti vibration pad and all accessories/equipments/protective devices etc and AMF control panel conforming to relevant IS, 26 fabricated with MS sheet 14 SWG, MS angle 65x65x8 mm duly painted, comprising of 1 no incoming 4 pole 800 amp ACB (Draw-out-manually operated), copper bus-bars, 4-pole contactors, energy meter, ammeter & voltmeter, power factor meter, frequency meter, indication light etc as per techincal specification and drawing including connections with un-armourmed LT XLPE insulated aluminium conductor cable conforming to IS:7098 part-I (latest version) between LT panel, AMF panel & alternator, construction of foundation as per recommendation of manufacturer, Erection, Testing & commissioning

1

1251067

2577948.66

... More
Supply, Installation, testing and commissioning of following Modular accessories as per explanatory note. Fan step regulator 230 V as similar to M/s Crabtree make Code-CQ 000385

15

355

5325

... More
Laying, underground/road/Railway track, recessing in platform /wall along with Rly. Track/in laid 14 RCC/GI pipe as required 1.1 KV grade LT XLPE insulated armoured, aluminium conductor cable including making chase & plastering after laying of cable/digging of cable trench, sand cushioning, protective covering with second class bricks, provision of cable route marker as per Tech. Specfn. including end terminations with Alu. Crimping socket/lugs, testing and commissioning of following sizes :- Up to 25 sq mm.

3500

30

216363

... More
Supply, fixing, testing & commissioning of 7 Watt LED lamp as required as per specification no. PCEE/NR/121-Elect/PS/2019 (REV.-'4'), dt: 04.11.2019 (Attached) or latest.

74

141

10434

... More
Laying of 3 core 120 to 185 Sq mm 11 kV HT XLPE (E) insulated armoured, aluminium conductor 30 cable, in sub-station trenches including holding of cable in trench with approved material cleats and on transformer / HT Panel side with frame fabricated from MS Angle of size 50x50x6 mm & MS Flat of size 50x6 mm as per drawing approved by Rly as per explanatory note including testing and commissioning. Note: Cable will be supplied from the store of SSE/E/C/MB

3000

146

438000

... More
Fabrication, supply, erection, testing and commissioning of Welding Point made of MS sheet 16 SWG with powder coated with grey colour thickness not less than 40 microns, comprising of 2 nos. cable glands 40 suitable for 120/185 sq. mm. 2 core LT XLPE as required armoured cable Aluminium bus bar of 400 Amp. rating, 2 nos. Porcelain insulators fitted on Bakelite sheet 325x40x12 mm thick, interconnection for welding cable terminal etc and provision of a hole in the bus bar for looping 2 nos. 120/185 sq. mm. 2 core cable as required at site including earthing. Drawing should be got approved by the contractor from Railways.

14

2840

39760

... More
Supply of M.S switch box conforming to IS 5133 (Part - I) - 1969 (latest version) with white Phenolic laminated sheet cover of approved make on front of box with brass screws & cup washers, recessing as per Tech. Specification including earthing. 300x200x100mm deep

25

108

5563.62

... More
Supply and laying of GI pipe class B ISI marked under road/clamping with erected pole or wall as per technical specifications given in explanatory notes and drawing as approved by Rlys for passing cable of following sizes: - 100 mm dia

250

291

149908.65

... More
Supply, fixing, testing and commissioning of 11 kV 200 Amp Gang Operated Switch to be provided 43 on erected MS tubular pole structure complete with GI pipe for operation from GI operating handle with locking arrangements insulators, dropout type fuses and all other accessories as per relevant IS specifications and as per explanatory note.

1

27694

27694

... More
Supply and fixing of GI clamp with nut bolt and washer on Rail poles or as per site requirement suitable for clamping of HT cable GI clamp made of 40x4 mm GI flat.

48

175

8400

... More
Supply, Installation, testing and commissioning of following Modular accessories as per explanatory note. 10 A Sockets with safety shutter as similar to M/s Crabtree make Code-CQ 000215

15

156

2340

... More
Design, Manufacture Supply, erection, testing & Commissioning of outdoor feeder pillar type 13 12 panel LT Distribution system suitable for 3 phase 4 wire 415 V AC supply system comprising: i) I/C MCCB 4P 125 A with 35 KA B/C -1No. ii) Out going MCCB 4P 63 A with 35 KA B/C -8Nos. iii) Out going MCCB 32 A 4P with 35 KA B/C- 4Nos. The feeder pillar shall be complete with Copper bus bars 150 Amps for Phases and 75 Amps for Neutral as per drawing approved by Railways and explanatory note.

1

123938

123938

... More
Supply of Piano type switch as per IS 4949 -1968(latest version) /Bell push as per IS 4794 (Part 2) -1986(latest version)/flush type socket outlet as per IS 1293 -1988(latest version) & installation on the recessed switch box including cutting of phenolic laminated sheet, connection, testing & commissioning as per Tech. Specifications. Piano Type switch 5A (1-way)

620

10

12775.72

... More
Supply, installation, connection and commissioning of INDOOR/OUTDOOR type End termination joint of 11 KV ( E ) HT XLPE cable as per ISS/IE rule and site requirement 3Cx120-185 sq mm

16

8501

136016

... More
Supply, erection/fixing of safety items Complete with: (a) Fire Extinguisher, dry chemical powder type (ISI marked) suitable for electric fire 10 Kgs. Capacity - 2 Nos. (b) Rubber Mat (ISI marked) non-skid type suitable for 11 KV AC supply of size 3600x1000x25mm - 2 Nos (c) GI Fire buckets, 24 gauge fitted on steel stand 25 as per approved drawing, each 10 Ltr. Capacity filled with clean dry ordinary sand. - 6 Nos. (d) First Aid Box complete with medicines of approved make - 1 No. (e) Electric shock treatment chart (Larger size) with Aluminum frame and glass on front or laminated as approved. - 2 Nos. (f) 11 KV/415 Volt danger plats conforming relevant IS. - 8 Nos. (g) Schematic diagram of HT/LT installation on white hylem sheet with alluminium frame. Approximate size 1200x600 mm. - 1 No. (h) Data's of transformer on white Hylum sheet with Aluminum Frame as approved. Appromimate size 900x600mm. - 2 Nos

1

9650

19884.79

... More
Design, manufacture supply, erection, testing & commissioning of double door Wall Mounted LT Switch Board suitable for 3 phase 4 wire 415 volt AC supply system comprising with: (i) Incoming MCCB 4 Pole 10 250 A 35 KA B/C-1No., (ii) Outgoing MCCB 125 Amps 35 KA B/C-2 Nos. (iii) Outgoing MCCB 63 Amps 35 KA B/C- 6 Nos. The Panel shall be complete with 400 Amps. Copper bus bars for Phases and 200 Amp. for Neutral, 3 phase 4 wire 415 volt voltmeter on incoming panel, digital amperes meter with selector switch and electronic energy meter on each O/G panels and as per explanatory note.

2

133674

267348

... More
Supply, erection, testing & commissioning of silicon rectifier battery charging set confirming to 13 relevant IS (latest) suitable for operation on 3 phase 4 wire 415 Volts AC Supply system with 125 Volts to 150 Volts DC output, 200 Amps. Capacity as per Tech specification including earthing, connections from LT panel board with 3.5 x 70 Sq mm armoured, aluminium conductor, XLPE insulated LT cable 1.1 KV grade confirming to IS 7098 (Latest Version)

2

57219

235810.94

... More
Laying, underground/road/Railway track, recessing in platform /wall along with Rly. Track/in laid 15 RCC/GI pipe as required 1.1 KV grade LT XLPE insulated armoured, aluminium conductor cable including making chase & plastering after laying of cable/digging of cable trench, sand cushioning, protective covering with second class bricks, provision of cable route marker as per Tech. Specfn. including end terminations with Alu. Crimping socket/lugs, testing and commissioning of following sizes :- Above 25 sq mm to 120 sq mm

6000

31

383271.6

... More
Supply of 16 meter height mast lighting system complete with raising lowering arrangement and 14 suitable Lantern Carriage for 9x150 watt LED. Light luminaries and control gear including accessories like lighting conductor, aviation neon light, integral drum winch compensating disc head frame, power tool, manual tool, double frame with foundation bolts etc. including casting of RCC foundation as recommended by manufacturer and as per explanatory note including erection, testing and commissioning.

2

244784

489568

... More
Supply of Piano type switch as per IS 4949 -1968(latest version) /Bell push as per IS 4794 (Part 2) -1986(latest version)/flush type socket outlet as per IS 1293 -1988(latest version) & installation on the recessed switch box including cutting of phenolic laminated sheet, connection, testing & commissioning as per Tech. Specifications. Plug socket outlet 5 Pin 5A

248

12

6132.35

... More
Manufacture, supply, installation, testing and commissioning of 18 W LED based pit light fitting suitable for operation on 12/24 V DC supply. The fitting shall be fabricated in IP 67 enclosure to ensure protection 39 against water and to be installed inside the maintenance pit in such a way to provide maximum light in upward direction. Note: The fittings are to be installed in such a way that the driver unit shall be placed outside the pit and only DC supply shall reach to the fitting inside the pit using multi-core PVC flexible wire. This arrangement is to be done by the tenderer within quoted rate.

60

6040

362400

... More
Supply of Piano type switch as per IS 4949 -1968(latest version) /Bell push as per IS 4794 (Part 2) -1986(latest version)/flush type socket outlet as per IS 1293 -1988(latest version) & installation on the recessed switch box including cutting of phenolic laminated sheet, connection, testing & commissioning as per Tech. Specifications. Plug socket outlet 6 pin 5/15A

106

25

5460.59

... More
Supply of M.S switch box conforming to IS 5133 (Part - I) - 1969 (latest version) with white Phenolic laminated sheet cover of approved make on front of box with brass screws & cup washers, recessing as per Tech. Specification including earthing. 100x100x60 mm deep

60

33

4079.99

... More
Supply, fixing, testing & commissioning of 600 mm (24") sweep ISI marked Air circulating fan as per tech. specification complete in all support as per site requirement

25

4899

122475

... More
Design , Manufacture, supply, erection, testing & commissioning of LT switch board suitable for 3 38 Phase, 4 wire 415 Volts, AC supply system comprising with: (I) Incoming 400 Amp 4 P 35 KA B/C MCCB = 1 NO (ii) Outgoing 250 Amp 4 P 35 KA B/C MCCB = 3 NOS (iii) Outgoing 125 Amp 4 P 35 KA B/C MCCB = 3 NOS (ii) Outgoing 63 Amp 4 P 35 KA B/C MCCB = 3 NOS The panel shall be complete with 400 Amp Copper Bus Bars for Phases and 200 Amp for Neutral and as per explanatory Note.

2

243574

487148

... More
Design, fabrication, supply, testing, commissioning of Feeder pillar(size-0.4mx0.4mx0.5m) made of 9 angle iron size-40x40x6 mm covered from all sides with MS sheet 20 SWG Including door with hinge, locking arrangement, nut & bolts, Aluminium bus bar (size-35x05x400 mm),Bakelite gutka, cable glands, Earthing points, cement, sand, interconnections etc. and painting with two coats of enamel gray paint over a coat of red oxide primer for antirust complete in all respect & as per site requirement.

16

3838

61408

... More
Supply and drawing of the following Sizes FRLS PVC insulated multi-stranded copper conductor 35 single core flexible cable conforming to IS 694 ( latest version ) in laid (recessed/Surface) MS/PVC/HDG Conduit pipe for wiring of point wiring/circuit wining/Sub main/Main as required & as per explanatory note including drawing, connection testing and commissioning 6 sq. mm.

2500

41

102500

... More
Connections with 40x6mm copper strip in 50 mm dia GI pipe Class 'B', 300 mm deep in ground / recessing in floor from earth electrode strip to HT Panel/LT Panel /AMF Panel/ Transformer / DG Set etc. as per approved drawing and technical specification including supply of material.

120

371

91737.91

... More
Supply and erection of 5 m high hot dip galvanized octagonal pole with top 70 mm around face bottom 130 mm around face made of 3 mm thick base plate size 200x 200x12 mm complete with appropriate 2 sleeve at the top of the pole for mounting single arm bracket 300 mm long suitable for 45-50 watt LED street light fitting including casting, muffing with cement concrete foundation(1:2:4) painting, earthing and foundation GI Nut bolt of suitable length with washer and smart pack, junction box with single pole MCB & terminal and as per explanatory note. a) Single arm

40

8788

351520

... More
Supply, Installation, testing and commissioning of following Modular accessories as per explanatory note. Bell push with neon as similar to M/s Crabtree make Code-CQ 000050

5

183

915

... More
Supply, erection, testing and commissioning of modular boxes concealed boards with white finish single mounting plate and fixing of switches/plug, sockets, fan regulators and connection to wiring, metal boxes boards are to be concealed in the wall of following sizes 6 Module

20

212

4240

... More
Supply, fixing, testing & commissioning of complete 40-45 watt LED street light fitting luminaires 5 operating voltage single phase 230 volt AC, 50 Hz with suitable pressure die cast aluminium housing and LED driver conforming to CEE/NR specification no. PCEE/NR/121-Elect/PS/2019 (REV.-'4'), dt: 04.11.2019 (Attached) or latest

150

3908

586200

... More
Fabrication, supply and erection of Fencing around the high mast in square shape size 2MX2M and 16 height 1.5 M from ground level fabricated from MS angle size 40x40x6 mm, MS flat size 40x6 mm AND WIRE MESH MADE OF 8 SWG wire and 1M wide hinged type lockable door as per drawing approved by Railway including grouting, CC platform around the high mast above 0.30 M above ground level and painting etc. and as per technical specification.

2

6598

13196

... More
Design & manufacture, supply, installation, fixing, testing & commissioning of 8 way MCB distribution board, dust & vermin proof, 3 phase, 4 wire 415 volt, AC supply system. The switch board shall be complete with inter connections, instrument connections with copper conductor cable as per IS 13032, 20 phosphatised & painted with epoxy polyster based powder paints. Three phase double door sheet steel enclosure detachable gland plates, flush/surface mounting for MCB's fitted with busbars, earth bars & neutral links etc.of suitable capacity, comprising of following i.e double door 8 way distribution board 1 no.1x40 A.MCB DP 10 KA,240/415V., 50 Hz & 6x6-32 A.MCB SP 10 KA,240/415 V,50 Hz complete in all respect as per site requirement/IE rule & tech. specification

16

3503

56048

... More
Supply & fixing of bracket on pillar or as required made out of one meter length 40 mm dia GI pipe class "B" ISI mark of approved make & shape and bracket shall be fixed with double clamps made out of GI strip of size 40x5 mm with help of suitable size GI nut, bolts & washers and as per explanatory note.

35

456

15960

... More
Design , Manufacture, supply, erection, testing & commissioning of outdoor type 15 Panel LT switch board suitable for 3 Phase, 4 wire 415 Volts, AC supply system comprising with: (i) Incoming ACB 4 Pole 800 Amp with microprocessor release (MDO type) = 2 No. (ii) Bus coupler ACB 1600 A 4 Pole (Fixed Type Manually 26 Operated) - 1 No. (iii) Outgoing MCCB 4 Pole 400 A 35 KA B/C = 4 Nos. (iv) Outgoing MCCB 4 Pole 250 A 35 KA B/C = 6 Nos. (v) Outgoing MCCB 4 Pole 125 A 35 KA B/C = 2 Nos. (vi) Changeover switch 800 Amps. = 1 No. The panel shall be complete with 1600 A Copper Bus Bars for Phases and 800 A for Neutral, 3 phase 4 wire 415 V electronic digital panel Ampere Meter & kWH meter on each outgoing feeder etc. and as per explanatory note and Voltmeter on each incoming feeder as per technical specification.

1

976590

976590

... More
Supply, erection, testing and commissioning of modular boxes concealed boards with white finish single mounting plate and fixing of switches/plug, sockets, fan regulators and connection to wiring, metal boxes boards are to be concealed in the wall of following sizes 12 Module

8

301

2408

... More
Earthing with 600x600x3 mm thick copper plate earth electrode as per IS 3043 (latest version) to 20 achieve earth resistance less than one ohm, including construction of masonry enclosure with hinged cover plate of cast iron with locking arrangement (Approx. size 600 x 600 mm) on top, watering pipe, connections from earth plate to top with 40x10 mm G.I. strip in 50 mm dia GI pipe class 'B' provision of each plate as per drawing and technical specification.

8

3606

59444.19

... More
Supply and recessing/fixing of M.S./PVC conduit pipe with accessories, junction box, etc including making chase, plastering/clamping etc as per technical specifications. PVC Conduit pipe conforming to IS 9537/Part III/1983 (Latest version) 25 mm (Medium)

5000

31

319393

... More
Laying of 400 Sq mm Single core Unarmoured LT XLPE insulated aluminium conductor cable 1.1 KV grade conforming to IS 7098 Pt.(Latest Version ) in trench of sub station including holding of cable with 47 approved cleats, filling of trench with dry ordinary sand ,holding of cable on panels with frames manufacture with MS angle 50x50x6mm and & MS Flat 50x6 mm as per drawing approved by railway and explanatory note including end termination in LT Panels/AMF Panels with aluminium crimping socket, Testing and commissioning. Note- Cable will be supplied from the store of SSE/E/C/MB.

300

30

9000

... More
Supply, erection, testing and commissioning of modular boxes concealed boards with white finish single mounting plate and fixing of switches/plug, sockets, fan regulators and connection to wiring, metal boxes boards are to be concealed in the wall of following sizes 4 Module

25

150

3750

... More
Fabrication, supply and installation of perforated GCGI Tray of following size including horizontal 21 and vertical bends, redusers, T's, cross members and other accessories duly galvanized and supporting/mounting with pillar/angle structure as well required at site as per explanatory notes. 75mm wide x50mm deepx1.6 mm thick.

1600

359

574400



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Related Tenders

Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.