New Okhla Industrial Development Authority Tender

... More
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of etender.up.nic.in - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.

New Okhla Industrial Development Authority Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date24 Nov 2023
Closing Date7 Dec 2023
Tender Amount₹ 80,53,395 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply, Installation Testing and commissioning of On Delay Timer.

8

13688

1711

... More
Supply, Installation Testing and commissioning of Over Current, Earth fault relay ADR141S

8

245440

30680

... More
S/F following piano type switch/ socket on the existing switch box/ cover including connection etc. as required

-

-

-

... More
Testing of 11KV CSS unit 03way, 02 Isolator and 01 Breaker with 990 KVA Transformer Testing of CSS:- IR value test, relay testing, primary injection test of 11KV CT's, breaker operation. Testing of 990 KVA Transformer:- IR value tesr, open circuit test, magnatic balancing test, magnetizing current, vector group test, DC component test.

2

42480

21240

... More
Location and pin pointing of 11 KV HT cable fault exposling the same in the underground 11KV HT cable including digging of trench upto the depth of the cable. Cutting the faulty cable and sealing of the faulty cable by providing fault location machine with operator (Cable fault locator) Complete in all respects as per direction of Engineer in charge (AOR)

2

13674

6837

... More
S/F Indication Light Blue & White (Make ESBEE/ Siemens/ Schnieder)

40

7400

185

... More
Rewiring for light/fan point/ exhaust fan point/ call bell point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable and 1.5 sq. mmm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/ PVC conduit including dismantling as required. Group B (DSR 2016/1.15.2)

80

35760

447

... More
Supply, Installation Testing and commissioning of 1000 Amp. A.C.B., 4 Pole, EDO with Microprocessor release (Make L&T C-Power/D-Shine

1

303950

303950

... More
Supply and fixing of recess/surface mounting round 24 watt to 32 watt LED Down Lighter having Powder coated die cast aluminium housing with extended heat sink diffuser/Reflector and Driver set complete in all respect. CAT-AAA (PS No.1404)

35

144550

4130

... More
i) 100 Amp 16KA TPMCCB ( DSR 2.2.1)

8

29808

3726

... More
Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.

-

-

-

... More
Supply, Installation Testing and commissioning of Shunt Release 240V coil L&T make.

10

53100

5310

... More
S/F VSS (Make Salzer/Kaycee)

40

7000

175

... More
Location and pin pointing of LT cable fault exposling the same in the underground LT cable including digging of trench upto the depth of the cable. Cutting the faulty cable and sealing of the faulty cable, by making experts technical staff. Complete in all respects as per direction of Engineer in charge (AOR)

10

23270

2327

... More
Dehydration & filteration of Transformer oil with testing of BDV at 2.5mm ball gap for 60 secound 50KV stands.

2

34928

17464

... More
Over hauling and servicing, De-carbonizing, lubricating and greasing the mechanism of 415Volt ACB including set right the control wiring also including the measurement of contract resistance & IR value of various live parts.

2

16520

8260

... More
S/F Volt Meter (Make AE/Procom/Conzerve)

40

90000

2250

... More
ii) 125 Amp 16KA TPMCCB( DSR 2.2.2)

12

49740

4145

... More
S/F of palm or pin type copper tin plated cable socket (lugs) to the cable leads, insulating with tape and making connection etc. complete in all respects as per direction of E/I. P.S No. 504.

-

-

-

... More
viii) 35 Sqmm

50

1829

36.58

... More
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth. 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed. All kind of soil.DSR 2.6.1 (Rate as per TAC order)

800

128384

160.48

... More
ii) 240 Sqmm

18

5777

320.96

... More
Supply and fixing of LED Tube Light with batten suitable for up to 1x22 watt LED tube light complete including tube etc. on surface complete in all respects. P.S No. 1413 Cat-AA.

150

180540

1203.6

... More
b) 3½ X 185 sq. mm ((Electrical DSR-18/Ite. No. 9.4.24 )

10

36830

3683

... More
Supply, Installation Testing and commissioning of 800 Amp. A.C.B., 4 Pole, EDO with Microprocessor release (Make L&T C-Power / D-Shine/ Siemens/ Schnieder)

3

864300

288100

... More
iii) 185 Sqmm

22

5010

227.74

... More
S/F APFCR Relay 7Amp., 415 volt 12Stage (Make L&T, Siemens/ Schnieder)

1

15250

15250

... More
S/F Push Button (Make ESBEE/ Siemens/ Schnieder)

30

1650

55

... More
i) 300 Sqmm x 3.5 core

800

1522672

1903.34

... More
S/F Ampere Meter (Make AE/Procom/Conzerve)

40

90000

2250

... More
S/F ASS (Make Salzer/Kaycee)

40

9600

240

... More
iv) 250 Amp 35KA TPMCCB ( DSR 2.2.7)

9

100260

11140

... More
i) 240 Sqmm x 3.5 core

350

569527

1627.22

... More
S/W of submain with 4 Nos. 16 Sqmm FR PVC insulated 1100 V grade multistrand single core copper conductor cable in existing conduit complete with supply of all material labour and T&P required for proper completion of the work as directed at site by E/I.( P.S No. 289L)

150

91686

611.24

... More
Supply of Fresh Transformer Oil complete in all respects as per direction of E/I. (AOR).

1200

120000

100

... More
(b) 15/16A switch (DSR 2016/1.23.3)

50

5500

110

... More
Providing and fixing following rating and breaking capacity and pole MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.

-

-

-

... More
ix) 400 Sqmm

20

14065

703.28

... More
Filling available excavated earth( excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth consolidating each deposited layer by ramming & watering, lead upto 50 m and lift upto 1.5 m. 2.25/P-67 (Rate as per TAC order)

800

87792

109.74

... More
Supply, Installation Testing and commissioning of 1600 Amp. A.C.B., 4 Pole, EDO with Microprocessor release (Make L&T C-Power/D-Shine

3

1092000

364000

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) .

40

286328

7158.22

... More
S/F Cylinderical Type Heavy Duty Mpp Capacitor 50 KVAR) @476 per Kvar) (Make L&T, Siemens/ Schnieder)

4

99000

24750

... More
S/F Cylinderical Type Heavy Duty Mpp Capacitor 10KVAR) @397 per Kvar) (Make L&T, Siemens/ Schnieder)

4

16400

4100

... More
Testing and repairing of control wiring of LT pannel for Auto/ Manual closing/ Tripping, indication, spring charging Motor.

1

17110

17110

... More
Location and pin pointing of LT cable fault exposling the same in the underground LT cable including digging of trench upto the depth of the cable. Cutting the faulty cable and sealing of the faulty cable by providing fault location machine with operator (Cable fault locator) Complete in all respects as per direction of Engineer in charge (AOR)

15

86055

5737

... More
vi) 70 Sqmm

10

790

79.06

... More
vi) 630 Amp 50KA FPMCCB( DSR 2.2.19)

2

65012

32506

... More
S/F Cylinderical Type Heavy Duty Mpp Capacitor 5KVAR) @397 per Kvar) (Make L&T, Siemens/ Schnieder)

6

12300

2050

... More
v) 95 Sqmm

10

1038

103.84

... More
Supply and Fixing of 400mm dia decorative type bracket fan.( wall fan) complete in all respects as per direction of E/I.

15

42411

2827.42

... More
S/F Cylinderical Type Heavy Duty Mpp Capacitor 25KVAR) @388 per Kvar) (Make L&T, Siemens/ Schnieder)

4

40000

10000

... More
Supply, Installation Testing and commissioning of Under voltage Release coil L&T make.

10

53100

5310

... More
S/W of submain with 4 Nos. 10 Sqmm FR PVC insulated 1100 V grade multistrand single core copper conductor cable in existing conduit complete with supply of all material labour and T&P required for proper completion of the work as directed at site by E/I.( P.S No. 289)

100

39412

394.12

... More
© 3 pin 5/6 A socket outlet (DSR 2016/1.23.4)

30

1740

58

... More
iii) 200 Amp 25KA TPMCCB ( DSR 2.2.5)

6

65718

10953

... More
Demolishing cement concrete manually/ by mechanical means including disposal of material with in 50 Mtr. Lead as per direction of E/I. Nominal concrete 1:3:6 or richer mix(i/c equivalent design mix) (DSR civil I No. 15.2.1/P-253)

30

32689

1089.64

... More
vi) 400 Amp 35KA TPMCCB( DSR 2.2.9)

2

43024

21512

... More
Supply & laying of Al. Conductor PVC Insulated armoured served sheathed cables 1100 Volt grade at a depth of below ground level over a cusion of 750mm below ground level over a cushion of 75mm. thick sand all round and protected with burnt bricks on sides and on top. on surface the cable run shall be fixed on M.S clamps etc. of suitable size or as directed by the Engineer - Incharge, complete in all respect, the armouring of the cable shall be properly connected with the earth conductor by clamps etc. as per PS No.-501 (Nicco,Grandlay, Havells,Kalinga, Skytone make)

-

-

-

... More
(d) 6 pin 15/16 A socket outlet (DSR 2016/1.23.5)

20

2560

128

... More
i) 300 Sqmm

50

23128

462.56

... More
vii) 50 Sqmm

35

1982

56.64

... More
S/W of submain with 2 Nos. 2.5 Sqmm FR PVC insulated 1100 V grade multistrand single core copper conductor cable in existing conduit complete with supply of all material labour and T&P required for proper completion of the work as directed at site by E/I.( P.S No. 289)

210

13629

64.9

... More
Supply and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11KV grade as required. (Electrial DSR-2018, Item No. 10.5)

-

-

-

... More
Rewinding & Repairing of 1000 KVA Transformer as per original winding 11/.433 KV with super enamelled copper wire as required gauge complete in all respects as per direction of E/I. It is also include the dismantling /Refixing/ Cartage from site to workshop / factory. The old material will the property of contrctor ( Old material rate already deducted in AOR)

1

375764

375764

... More
S/I/T and commissioning of 300mm dia 900 R.P.M Exhaust fan with louvered shutters. complete in all respects as per direction of E/I.

5

17250

3450

... More
Testing and servicing of 11KV VCB such as Programming of IDMT relay, Servicing of Breaker, Primary injection test on 11KV indoor type C.T.

3

49560

16520

... More
iv) 120 Sqmm

15

2070

138.06

... More
(a) 240 Sqmm ( Item No. 10.5.3 P-37)

4

68664

17166

... More
Supply and burring of 75 mm dia 3 Mtrs. long Electrode casted with maintenance free, conductive concrete, non corrosive mixture ( Ultra low Resistive carbon 0.001 ohm/mtr) in the ratio of 3:1:1 ( marconite: cement : water) on M.S Rod with hole ( 16mm diameter x 3 Mtrs) will be vertically installed for earthing with 1 Mtr G.I strip ( 25mm x 2.5mm) connected with SS nut bolt.The earth electrode will be installed into the 100mm pit up to 3000mm depth. nominal soil will be used as backfill material. Make: As approved in U.P.P.W.D & C.P.R.I Certified P.S No 729(C)

20

464920

23246

... More
(a) 5/6 A switch (DSR 2016/1.23.1)

100

4500

45



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.