Military Engineer Services Tender

View complete overview of Arunachal Pradesh MES Tender

Military Engineer Services

OthersElectrical and Maintenance WorksPower Conditioning
Views311 Views
Downloads126 Downloads

Opening Date

06 Oct 2021

Closing Date

06 Nov 2021

Tender Amount

₹ 16,30,000

Costs

Summary

Provn Of Servo Voltage Stabilizer At Likabali Mil Stn

Description

Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

  • Tender Id

    Unregistered TenderId
  • BidAward Id

    Unregistered BidAwardId
  • Tender No

    Data for unregistered User Data for unregistered User Data for unregistered User Data for unregistered User
  • Tender Authority

    Data for unregistered User Data for unregistered User Data for unregistered User Data for unregistered User
  • Purchaser Address

    Authority for unregistered User
  • Email

    Data for unregistered User
  • Website

    wwww.unregistereduser.com

BOQ Items

ItemQuantityUnitsRateAmount
... more
Supply & fixing 3 phase servo controlled voltage stabilizer of capacity of 250 KVA (conforming to BIS 9815:Part 1: 1994) for automatic operation, rated frequency 50 Hz, naturally oil cooled, indoor type with protection, unbalanced type, copper wound, metallic body duly powder coated with lifing hooks-02 nos and digital display of volt/amp meter etc & designed for input variation between 210V to 480V with output voltage stabilizer at 415 with accuracy ± 2.5% and speed of correction 8 Volts per second at 430 V and of 250 KVA, with relay free smooth and silent operation, having no distortion in wave form, response time not to exceed 20 milli seconds, sensitivity (+/-) 1% and having efficinacy more than 95 %, complete all as specified and as directed.
2Each job--
... more
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 3 core with reduced neutral conductors (3½ core), nominal cross sectional area of main conductor 240 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through GI pipe laid under floors/roads, through concealed GI pipe along wall etc. complete all as specified and as directed.
52Running Metre--
... more
Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. or for cable laying or not exceeding 10 sqm on plan and not exceeding 1.5 m in depth and getting out in hard/ dense soil complete all as specified and as directed.
12Cum--
... more
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft/ loose/ hard/ dense soil complete all as specified and as directed.
8.5Cum--
... more
Removing excavated material (soils) not exceeding 50 m and depositing where directed at a level n exc. 1.5 m above the starting point
3.5Cum--
... more
Supply & spreading in trenches dry river sand cushioning to underground cable in trenches including spreading, levelling hand punning down complete all as specified and directed Note:- Depth of sand cushioning will be measured after punning down and levelling the sand properly.
3.5Cum--
... more
M & L for laying of bricks locally available sub class 'B' bricks (old size) for cable protection cover laid flat and dry in trenches over the cable perpendicular to the direction of cable all as directed.
400Each--
... more
M & L for fabrication of LT feeder pillar box, out door type, tent roof, made out of 3.15 mm thick CRCA sheet and mounted on MS angle 40 mm X 40 mm X 5 mm suitable for 3 Phase, 415 volts, AC supply, 50 Hz, with opening door both side with rubber bedding, locking arrangement and painting with two coats of synthetic enamel paint over a coat of red oxide zinc chrome prime in grey colour complete all as specified and as directed and comprising the followings:-(a) Aluminium bus bar for three phase with neutral of capacity 300 Amps- 01 set (b) MCCB, 4 pole, 250 Amps capacity, 35 kA rupturing capacity, 430 volts, AC, 50 Hz- 01 No (c) MCCB, 4 pole, 125 Amps, 25 kA rupturing capacity, 430 volts, AC, 50 Hz- 02 Nos (d) RBI Indicating lamp RYB with holder - 01 No complete all as required at site.
1Each Job--
... more
M & L for earthing complete with galvanised steel plate earth electrode 600 mm X 600 mm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to earthing lead of 32 mm X 6 mm galvanised mild steel strip by means of bolts, nuts, check nuts and washers of galvanised iron from earth plate to test point upto 7.5 metre including all as shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete chamber in cement concrete M15 (Nominal Mix) using 20 mm nominal size coarse aggregate, precast RCC cover slab in cement concrete M15 (Nominal mix) using 20 mm nominal size coarse aggregate of size 40 cm X 40 cm X 5 cm reinforced with 8 mm dia TMT bars @ 150 mm c/c with one handle for lifting made out of 8 mm dia bar, GI funnel, GI wire mesh filter, 20 mm dia GI pipe medium grade for watering, 40 mm dia GI pipe medium grade for protection of earthing lead, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil/ strata and testing complete all as specified and as directed by the Engineer-in-charge.
4Each--
... more
M & L for staging and weather protection shed of size 2X 3 m for servo voltage stabilizer mounted on brick staging , prepainted galvalume Al-Zn coating GI based plain steel sheet of 0.5 mm thickness of any colour having tensile strength of 550 MPA complete all as specified and directed by Engr in charge.
1Each job--
Evaluation Notes How It Works ?

Result

No Result Available
Click here to view all tender results of this authority
Business Providers

Check Business Providers

Business Seekers

Check Business Seekers

https://bidassist.com/pricing/1?referer=Banners
7 DAY
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.
whatsapp chat