Indian Oil Corporation Limited Tender

... More
If you want to inquire about any e-tender the Haryana government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Haryana tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Haryana etender you're looking for. Read further to learn how to search and bid for etender Haryana.

Indian Oil Corporation Limited - IOCL Tender

Works
Civil And Construction
Pipe Line Project
Eprocure
Opening Date2 Feb 2024
Closing Date11 Mar 2024
Tender AmountRefer Documents 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
2 Pair unarmoured Telephone Cable as per specifications

750

49082

-

... More
6", 600#/900#, W/W

10

142437

-

... More
Single Tee with door (110x110x110 mm)

20

5354

-

... More
WARNING SIGN

290

3035314

-

... More
Supply of all materials, consumables, providing all equipment & resources for the complete activity of commissioning of Liquid Petroleum Gas Pipeline (LPG) including Mainline and Stations with proper pres surization of mainline and station piping with Nitrogen, batch pigging followed by vaporized LPG and effective line fill by pressurization of line fill LPG as per approved procedure and Specification requirement including providing expert services for vetting of commissioning procedure and presence of expert to guide & monitor the complete commissioning activities, providing all supervisory/expert services, other manpower and all resources for the execution of the complete service meeting with international practices and standards, observing all statutory and other governing rules & standards in all respect and as per the approved scheme and guidance/direction of Engineer - in - Charge. i) The offer shall be inclusive of supply of nitrogen, pig train, all consumables, taxes, duties as applicable and excluding GST. ii) IOCL's responsibility shall be limited to arrangement of a) Fire tender b) Ambulance c) Water supply d) Providing LPG in tanker truck and subsequently lining up of the pipeline system for LPG line fill.

-

-

-

... More
All works upto plinth level

25

276492

-

... More
18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster 1:6 (1 cement : 6 fine sand).

1671

878644

-

... More
450 mm x 450 mm rectangular section radial drain.

11

36840

-

... More
Suspended floors, roofs, landings, balconies and access platform

660

602339

-

... More
16 A power plug point wiring: Wiring for 250 V single phase and neutral 16 amps modular power plug point with PVC insulated 4 sq. m m. copper conductor wires for phase & neutral, 650 V grade including earthing, the third pin with 2.5 sq. mm copper conductor earthi ng insulated continuity wire, complete with providing and fixing of 6 pin 16/6A modular socket and 20/10 A modular switch (1 plug po int per circuit) as per specifications and drawings

34

125317

-

... More
Fasteners for Flanges 6" x 300# (0.750" Dia. X 5.25" Length)

420

85862

-

... More
Services-CSW Electrical

-

-

-

... More
Plantation of Trees, Shrubs and Hedges at site including watering and removal of unserviceable materials as per direction of the Eng ineer-in-Charge (excluding cost of plant & water):

-

-

-

... More
New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)

15566

3376016

-

... More
1" NB Piping

1

1367

-

... More
Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain w indow sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing :

-

-

-

... More
Finishing walls with Acrylic Smooth exterior paint of required shade :

-

-

-

... More
Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in widt h as well as 10 sqm on plan) including getting out and disposal of excavated earth, all works up to any lead and lift, as directed b y the Engineer-in-Charge :

-

-

-

... More
Providing and fixing removable raised/ false access flooring with system (Unitile Solid Feel (USF) 800 or equivalent) and its compon ents of approved make for different plenum height with possible height adjustment up to 50 mm, comprising of modular load bearing fl oor panels supported on G.I. rectangular stinger frame work and G.I. Pedestal etc. all complete, as per the architectural drawings, as specified and as directed by Engineer-in-charge consisting of: (A) Providing at required spacing to form modular framework, pedes tals made out of G.I. tube of thickness minimum 2 mm and 25 mm outer diameter, fully welded on to the G.I. Base plate of size 100mm x 100mm x 3mm at the bottom of the pedestal tube, G.I. pedestal head of size 75 mm x 75 mm x 3.5 mm welded with G.I. fully threaded stud 16 mm outer diameter with two G.I. Check nuts screwed on the stud for level adjustment up to 50 mm, locking and stabilizing the pedestal head in position at the required level. The pedestals shall be fixed to the sub-floor (base) through base plate using epox y based adhesive of approved make or the machine screw with rawl plug. (B) Stringers system in all steel construction hot dipped gal vanized of rectangular size 570x20x30x0.80 mm thick having holes at both ends for securing the stringers on to the pedestal head usi ng fully threaded screws ensuring maximum lateral stability in all directions, the grid formed by the pedestal and stringer assembly shall receive the floor panel, this system shall provide adequate solid, rigid support for access floor panel. The system shall pro vide a minimum clear uninterrupted clearance between the bottom of the floor for electrical conduits and wiring etc. all complete as per the architectural drawings, as specified and as directed by the Engineer-in-Charge. (C) Providing and fixing Access Floor panel of 600x600x32 mm medium grade Filled Steel anti static high pressure Lamination of 800H grade (FS800H). Access Floor panel shall be steel welded construction with an enclosed bottom pan with uniform pattern of 64 hemispherical cones. The top and bottom plates of Steel Gauges: top 0.6 mm and bottom 0.7 mm fused spot welded together (minimum 64 welds in each dome and 20 welds along each flange) . The panel should be corrosion resistant epoxy coated for lifetime rust protection and cavity formed by the top and bottom plate is filled with Pyrogrip non-combustible Portland cementitious core mixed with lightweight foaming compound. The access floor shall be factory finished with Anti-static High Pressure laminate with Non Warp technology up to 1 mm thickness for superior adhesion and Sur face flatness within 0.75 mm.The panel is to withstand a Concentrated Load of 363 Kg applied on area 25 mm x 25 mm without collapse in the centre of the panel which is placed on four steel blocks. The panel will withstand and Uniformly Distributed Load (UDL) minim um 1250 Kg/sq.m. and, an impact load of 50 Kg all complete as per the approved manufacturers specification and as per the direction of the Engineer-in-Charge. All specification must be printed on the side of the panel to ensure the quality of the product :

-

-

-

... More
Supplying and placing in position 5.0 mm thick steel chequered plates over cable ducts, valve pits etc. including provision for lift ing arrangements complete in all respects inclusive of cost of all labour, materials, tools, tackles etc. as per drawings, specifica tions and directions of the Engineer-in-Charge.

80

518364

-

... More
1", 600#/800#/900#/1500#, W/W

110

261157

-

... More
Providing and fixing on wall face Unplasticised-PVC (UPVC) moulded fittings/ accessories for Un-plasticised Rigid PVC rainwater pipe s conforming to IS:13592 Type A, including jointing with seal ring conforming to IS:5382, leaving 10 mm gap for thermal expansion :

-

-

-

... More
Size of Tile 800 x 800 mm

43

92118

-

... More
Providing barricading of 3.0 m height made of 1mm thick G.S. corrugated sheet with steel angle post (ISA65x65x6) at every 1.5 m inte rval and steel angle bracings (ISA 50x50x6) at every 3.0m interval, embeding posts in cement concrete (1:2:4) padestals of size 450m m x 450mm x 750mm), providing necessary bolts, nuts, fixing, etc. including painting of steel sheet and angles with two coats of alu minium/ synthetic enamel paint over a coat of red oxide zinc chrome primer, inclusive of cost of all labour, material, tools, tackle s, etc. complete in all respects as per drawing, specifications and directions of the Engineer-in-Charge. [Note: This item shall be operated under specific approval of the Engineer-in-Charge].

877

2701833

-

... More
"EARTH ELECTRODES Supplying, installation, testing of GI earthing electrode, including the supply and installation of the CI cover, charcoal /special backfill etc. and construction of chamber; complete as per drawings,specifications and directions of the Site Engineer, Including the cost of all labour, tools, materials etc. complete in all respects."

81

1502759

-

... More
COMPOSITE

-

-

-

... More
6" Spectacle Blind 600# F/F

18

540111

-

... More
10" NB - Single Cut Joint

1

12705

-

... More
Finishing walls with Acrylic Smooth exterior paint of required shade :

-

-

-

... More
C.P. brass double coat hook (Ref. Make: JAQUAR, Model: Cat. No. 1161 or approved equivalent).

3

4046

-

... More
For fixed portion :

-

-

-

... More
Providing and fixing in position 12 mm thick bitumen impregnated fiber board conforming to IS:1838, including cost of primer, sealin g compound Grade-A in expansion joints. [Note: Unit "CM" shall mean "PER CENTIMETRE DEPTH PER 100 METRE"]

2

1468

-

... More
Providing, laying, spreading and compacting graded stone aggregate (size range 53 mm to 0.075 mm) to wet mix macadam (WMM) specifica tion including premixing the material with water at OMC in for all leads & lifts, laying in uniform layers with mechanical paverfini sher in sub-base/ base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achieve the desired density, complete as per specifications and directions of the Engineer-in-Charge.

50

173914

-

... More
3"x1" 300# Unequal Tee-ASTM A420 Gr.WPL6

40

61784

-

... More
2", 600#/900#, F/F

2

6593

-

... More
Civil SV ITC

-

-

-

... More
With common burnt clay F.P.S. (Non-modular) bricks of class designation 7.5

5

166440

-

... More
Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :

-

-

-

... More
6"x4" 600# Unequal Tee

12

82666

-

... More
Composite-CSW Electrical

-

-

-

... More
Composite2- CP System Electrical

-

-

-

... More
1" 3000 Class HALF COUPLING

80

17369

-

... More
Preparation and consolidation of sub-grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the s ub grade and disposal of surplus earth with lead up to 50 metres.

2025

417971

-

... More
Conducting "Soil Resistivity Survey" at anode bed location after ascertaining its suitablity with respect to the existing system , f or installation of Anode Bed (deep / shallow / distributed), as per the specification, approved procedures and instructions of Site Engineer / Engineer-in-Charge.

-

-

-

... More
Magnesium Anode

113

882197

-

... More
Finishing walls with Acrylic Smooth exterior paint of required shade :

-

-

-

... More
Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per directions of the Engineer-in-Charge.

1

1746

-

... More
Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrange ments for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27. 5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS:4454 (Part-1) and M.S. top co ver of required thickness for rolling shutters :

-

-

-

... More
External Work: Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water suppl y including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, t renching, refilling & testing of joints complete as per directions of the Engineer-in-Charge :

-

-

-

... More
Providing and fixing ISI marked flush door shutters conforming to IS:2202 (Part I) non-decorative type, core of block board construc tion with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face vene ers on both faces of shutters :

-

-

-

... More
6"x4" x Concentric Reducer x 600#

6

14623

-

... More
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in :

-

-

-

... More
PMCC (MVP- IOCL-Jalandhar-01)

1

548382

-

... More
Supply of reducers- flame proof and weather proof including EP/WO certificates

-

-

-

... More
Providing and fixing in position pre-moulded joint filler in expansion joints. [Note: Unit "CM" shall mean "PER CENTIMETRE DEPTH PER CENTIMETRE WIDTH PER METRE LENGTH"].

1313

5345

-

... More
Pipe size 3 inch NB to 6 inch NB

2

1276

-

... More
Supply of Electronic Marker Locator cum Cable/ Pipe Locator, Fault Locator as per tender specifications

1

312662

-

... More
CLADDING WORK :

-

-

-

... More
Supply and Erection of Structural Steel: Supplying at site, steel structural items such as steel plates, bars, MS gratings, chequere d plates, angles, beams channels, commercial quality heavy pipes, C.I. Rollers, bolts & nuts, washers, grouting bolts, padding plate s etc., fabrication and erection of saddle supports and other type of supports for pipes manifolds and valves, fabrication and erect ion of platforms walkways, stairways etc., sand blast/ power brush cleaning, priming and painting the finished structures including supply of all other inputs such as labour, materials, consumable etc. necessary to perform and complete the work in all respect, in accordance with drawings, specifications and instructions of the Site Engineer / EIC.

24

3309758

-

... More
Supplying and fixing Road Hump of minimum size 350 mm width x 50 mm thick made of Carbon Black mixed Rubber with Additive of LDPE fo r reinforcement & UV resistant colouring agent of black & yellow colour with 4 reflective glass beads, of weight not less than 16 Kg /metre, and capacity to withstand minimum 35 tonne weight (moving vehicle load) including cleaning the road surface of all dirt, sca les, oil, grease and foreign material etc. and fixing the hump on the Road top as per manufactures specifications with necessary fas teners complete in all respects inclusive of cost of all labour, materials, fasteners, tools, tackles etc. as per specification and directions of the Engineer-in-Charge.

25

83975

-

... More
In all kinds of soil

105

25144

-

... More
6.625" OD

850

5787310

-

... More
10" x 150# 90° LR Bend

40

331344

-

... More
Providing and fixing ball bearing for rolling shutters.

2

1105

-

... More
Integrity testing of Pile using Low Strain/ Sonic Integrity Test/ Sonic Echo Test method in accordance with IS:14893 including surfa ce preparation of pile top by removing soil, mud, dust & chipping lean concrete lumps etc. and use of computerised equipment and hig h skill trained personal for conducting the test & submission of results, all complete as per directions of the Engineer-in-Charge. [Note: Unit "EA" shall mean "PER TEST"]

1

1236

-

... More
100x100 mm size P-type

5

15189

-

... More
Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diam eter, 1.8 m long complete as per standard design :

-

-

-

... More
3" Spectacle Blind 600# F/F

4

54015

-

... More
Painting foundation concrete (RCC) with hot bitumen of grade VG-10 @ 17 Kg/10 sqm including cleaning the foundation concrete with br ushes etc. complete in all respects inclusive of cost of all labour, materials, tools, tackles etc. as per drawings, specifications and directions of the Engineer-in-Charge.

232

158099

-

... More
Providing and laying autoclaved aerated cement blocks masonry with 150 mm/ 230 mm/ 300 mm thick AAC blocks in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive m ortar all complete as per directions of Engineer-in-Charge. [Note: The payment of RCC band and reinforcement shall be made for seper ately].

215

1879056

-

... More
"Lighting Distribution Board / AC Distribution Board: Supply , installation, testing and commissioning of TPN lighting / AC Distribution board of approved make, with rating and feeders as per specification. The DB shall be of IP-42 protection class and shall conform to IS 8623. The board shall be fitted with an acry lic door as per specifications and drawings: "

-

-

-

... More
Civil SV Non ITC

-

-

-

... More
Control cables (T&I) : OD above 30 mm and upto 40 mm

7100

919485

-

... More
Heavy Duty Protective Cover

1

12522

-

... More
DC distribution board

2

9392

-

... More
4" BLRF 150#

2

2395

-

... More
Single half stall urinal with 5 litre P.V.C. automatic flushing cistern

1

12326

-

... More
Commissioning of Mainline CP system

1

138870

-

... More
1/2" Cable Glands

50

6346

-

... More
3" ANSI 600# 45 deg LR Bends

2

1505

-

... More
2"x1" 600# Unequal Tee

8

5833

-

... More
6" Spectacle Blind 300# F/F

6

139284

-

... More
1 1/4" (5/4") Cable Glands

30

14705

-

... More
Mainline Laying

-

-

-

... More
Supply and Erection of GI Structural: Supplying at site, GI structural items such as flat, bars, chequered plates, angles, beams cha nnels, commercial quality pipes,bolts & nuts, washers, grouting bolts, fabrication and erection of various structures items includin g supply of all other inputs such as labour, materials, consumable etc. necessary to perform and complete the work in all respect, i n accordance with drawings, specifications and instructions of the Site Engineer / EIC.

3500

863170

-

... More
Low temparature protective clothing

1

615333

-

... More
3" ANSI 600# Equal Tee

4

3860

-

... More
Supply of ASTM A333 Gr.6 pipes at respective stations as per Station wise Break up of material supply and as per technical specific ations from approved vendors specified in tender document

-

-

-

... More
Zinc Anode for Hot spot protection : Supply, Installation , testing and commisioning of Zinc anode (minimum 10 Kg each) including it s tail cable of size of 1c x 25 sq.mm. XLPE/ PVC insulated stranded copper cable of total length 10 meter including PVC cap, special back-fill material ( filled in cotton sack) with sealing compound complete in all respect including its excavations, back filling e tc. as per specifications and drawings. The work complete in all respect shall include supply of all labour , tools etc. and shall b e carried out as per the directions of the Site Engineer / Engineer-in-Charge and as per AFC drawings.

-

-

-

... More
All works upto plinth level

1

10531

-

... More
Installation of BALL/GATE Valves MOV/HOV: Taking delivery of valves of all types and pressure rating from the designated location wi thin station premises, transporting the same to site, erecting above ground on preconstructed foundations or underground including e arth work in excavation and filling for under ground valves at elevations specified in the drawings, priming and painting of above g round valves, PU Painting of under ground portions (if applicable) or flood coating and wrapping of under ground portions (if applic able) including all inputs, labour, material and consumable (other than those specifically undertaken to be supplied by the owner) and completing the work in all respects in accordance with the drawings, manufacturer's installation instructions and specifications and instructions of the Site Engineer / EIC.

-

-

-

... More
Supplying and stacking of well decayed cattle manure at site including royalty and carriage up to any lead complete. [Note: Volume o f cattle manure measured in stacks will reduced by 8% for payment].

6

2130

-

... More
Providing and fixing 12 mm thick Elevational Brick Tiles for facia, vertical face of walls, etc. at all levels and locations laid ov er and including a backing coat of 15 mm thick cement mortar (1 cement : 3 sand) and joints filled with coloured cement of same colo ur as tiles complete in all respects inclusive of cost of all labour, materials, tools, tackles etc. as per specification and direct ions of the Engineer-in-Charge.

10

17022

-

... More
Providing and fixing on wall face Unplasticised Rigid PVC (uPVC) rainwater pipes (110 mm diameter, single socketed) conforming to IS :13592 Type-A, including jointing with seal ring conforming to IS:5382, leaving 10 mm gap for thermal expansion.

429

172327

-

... More
CABLE MARKER: Supply, erection & installation of MS cable markers, including excavation, installation of the markers, cement concret e grouting, backfilling, materials, labour, tools and tackles, consumables etc , as per drawings, specification and directions of Site Engineer / Engineer-in-Charge.

311

874260

-

... More
Applying priming coat :

-

-

-

... More
Providing and fixing Unplasticised PVC (uPVC) pipe clips (110 mm) of approved design to unplasticised-PVC rainwater pipes by means o f 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.

44

16733

-

... More
Pair of Rubber hand gloves for Electrical work bearing IS mark

2

2872

-

... More
Installation of Manual Call Point (Explosion Proof & Weather Proof) in Hazardous area, terminating the cables at field and control p anel end, connecting to earthing grid by supplying and installing all the required materialssuch as supporting structure, cement con crete, painting, GI wire etc.(excluding supply of the Manual Call Point) complete in all respectsas per specifications.

13

50049

-

... More
1" SWMG ANSI 600#

40

5097

-

... More
Casting, supplying and erecting in position precast reinforced cement concrete elements (with proper lifting lugs) for trench & drai n covers, shelves, partitions, post, slabs etc. for all leads and levels including making necessary moulds, vibrating, tamping, cur ing, finishing the top surface with cement mortar 1:3 (1 cement : 3 fine sand) to give a smooth and even surface, transportation to Site, aligning and fixing in position with cement mortar 1:3 (1 cement: 3 find sand,) including making recess in brick wall for pla cing the precast element in position and making good the same etc. complete in all respects inclusive of cost of all labour, materia ls, tools, tackles etc. as per drawings, specifications and directions of the Engineer-in-Charge. [Note: Payment for Reinforcement s hall be made as per relevant item of SOR.] :

-

-

-

... More
18" Sweep

10

118150

-

... More
Demolishing brick work in cement mortar manually or by mechanical means including stacking of serviceable material and disposal of u nserviceable material within 50 metres lead as per the directions of Engineer-in-Charge. [Notes: (1) Dismantling shall be allowed du ring day shift only & prior permission for the same shall be obtained. (2) Providing of necessary covers/ barricades around the work area shall be done prior to dismantling operations]

4

7742

-

... More
Safety Torch

1

4948

-

... More
Type DAC (With Ingress Protection IP:55)

39

1368366

-

... More
Surge Diverter/Spark Gap Surge Arrestor

15

128974

-

... More
1" plugs

30

2614

-

... More
Fasteners for Flanges 8" x 150# (0.750" Dia. X 4.75" Length)

160

20390

-

... More
1" SWMG ANSI 300#

60

5380

-

... More
Design, detailed engineering & installation of pipeline / pipeline & OFC conduit across rivers, NH, SH, Expressways, Railways, etc by HDD method. #Complete work for the crossing (between the limits, as indicated in the approved drawings) including mobilization & de-mobilization at site(s), supply of all materials as per the `Scope of Supply' and all consumables, equipment, manpower & other resources and arranging the required land for site preparations and execution of, but not limited to, the following works in accordance with the specifications, drawings and as per all provisions of the contract document and instructions of the Owner. #Interpretation of data of hydrological / geo-technical surveys furnished by the Owner, carrying out fresh topographic survey of the rivers, NH, SH, Expressways, Railways, etc & developing new profile drawing for the crossing location, carrying out additional surveys required for collecting data relevant to design and construction of the crossing, performing all engineering & design calculations, preparation of all necessary construction drawings for approval of the Owner as per the provisions of contract document, preparation of detailed construction method statement and design analysis. #Taking delivery and transportation of Owner-supplied 3LPE coated pipes to the work site from designated stockpile location, inspection of the coated pipes visually and/or with holiday detector for defects, including arranging all necessary intermediate storage area required thereof till the pipes are installed in permanent position. #Complete site preparation including arranging of required land, setting up of fabrication yard, preparation of temporary arrangement for pipeline stringing, launching etc. #Carrying out repair of pipe defects, replacement in the case of non-repairable defects and repairing damages to pipe coating including defects/ damages occurring during transportation and handling. #Pre-construction surveys and collection of all necessary data. #String preparation including repair of pipe and pipe coating defects, welding, non-destructive testing of welds including 100% radiography (by X-ray), supply of films & all equipment and providing all facilities to Owner's representative(s) for examining radiographs, repair of defects in the. welds and re-testing etc. #Coating of the field joints of the pipe string to be installed by HDD method with DIRAX heat shrink sleeves of M/s Raychem's make, DDXTM Directional Drilling Kit of M/s Canusa or of any other approved make used for HDD crossings. #Repair of all coating damages in the pipe section to be laid by HDD method by full encirclement sleeves using suitable cut sections of approved quality of heat shrink sleeves of M/s Raychem make, DDXTM Directional Drilling Kit of M/s Canusa or of any other approved make. #Fabrication of 89mm OD steel conduit with an inner duct of 40mm OD HDPE pipe for OFC (wherever OFC has to be laid along with the carrier pipeline). #Supply & fixing of easy to install heat shrinkable duct end caps for HDPE conduit for OFC (wherever OFC has to be laid along with the carrier pipeline). #Carrying out air cleaning, gauge pigging and pre-installation hydrostatic testing of the complete pipeline string, as per the speci fications, including repair of defects and retesting etc. #Installation of the pipeline / pipeline and OFC conduit as a bundle crossing below the rivers, NH, SH, Expressways, Railways, etc by single horizontal directional drilling operation to the correct profile as per the approved drawings. #Carrying out post-installation hydrostatic testing of HDD pipe string (along with transition pipe section). #Carrying out post-installation coating survey as per approved procedure. #Restoration, clean-up and disposal of drilling fluid, waste and all other surplus materials etc. #Transportation of surplus Owner-supplied pipes to the designated stockpile location of the Owner. #Preparation of as-built drawings and other records etc. #All other works not specifically listed herein, but required as per specifications, drawings, provisions of the contract document, calculations and construction method statement, leading to successful completion of the works. Note:-The Contractor shall have the option for installation of 89 mm OFC conduit as Bundled HDD installation along with the HDD installation of carrier pipe OR as a separate HDD instalation. However, the payment and payment terms shall remain the same in both the cases.

-

-

-

... More
With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel work (second coat).

6

214

-

... More
2", 150#/300#, F/F

1

3296

-

... More
6"x2" X 600# Weld-o-let

40

115309

-

... More
18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster 1:6 (1 cement : 6 fine sand).

508

267116

-

... More
8" NB - Single Cut Joint

2

20744

-

... More
Providing and laying seal coat over prepared surface of road with bitumen heated in bitumen boiler fitted with the spray set sprayin g using 98 kg of bitumen of grade VG-10 and blinding surface with 0.90 cum of stone aggregate of 6.7 mm size (Passing 11.2 mm sieve and retained on 2.36 mm sieve) per 100 sqm of road surface, including rolling and finishing with power road roller all complete. [No te: This item to be operated only with the prior approval of the Engineer-in-Charge].

150

19583

-

... More
6.625" in Rocky Soil

10

303260

-

... More
6.625"

980

2243416

-

... More
3" NB - Single Cut Joint

3

13370

-

... More
Providing and fixing on wall face Unplasticised-PVC (UPVC) moulded fittings/ accessories for Un-plasticised Rigid PVC rainwater pipe s conforming to IS:13592 Type A, including jointing with seal ring conforming to IS:5382, leaving 10 mm gap for thermal expansion :

-

-

-

... More
Applying priming coat :

-

-

-

... More
"6 A plug point wiring: Wiring for 250 V single phase and neutral 6 amps modular plug point with PVC insulated 2.5 sq. mm. copper conductor wires for phase & neutral, 650 V grade including earthing, the third pin with 1.5 sq. mm copper conductor earthing insulated continuity wire, comple te with providing and fixing of 5 pin 6A modular socket and 10 A modular switch (1 plug point per circuit) as per specifications and drawings."

34

91194

-

... More
Corrosion Coupon: Supply of TOR Fitting Complete With Plug & Cap and Full bore Threaded Ball Valve

-

-

-

... More
Polyester powder coated aluminium (Minimum thickness of polyester powder coating 50 micron)

405

295958

-

... More
Supplying and filling selected earth/ moorum (excluding black cotton soil) from Contractor's own borrow areas including royalty, wit h all leads and lifts in low laying areas and filling to required grade and level including watering, compacting at optimum moisture content to 90% of Proctor's density, consolidation and rolling with 8 to 10 tonne power roller in layers not exceeding 20 cm thic kness, complete in all respects inclusive of cost of all labour, materials, tools, tackles etc. as per drawings, specifications and directions of the Engineer-in-Charge.

23448

12749432

-

... More
Construction of second class brick masonary open surface drain (Size: 200mm wide & 200mm average depth) in cement mortar 1:4 laid ov er a bed of 150mm thick cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) including mak ing haunches and providing 15mm thick cement plaster in CM 1:4 (1 cement : 4 coarse sand) with a floating coat of neat cement inside and its top and exposed surfaces, including excavatioin, disposal of the surplus earth up to any lead and lift as per standard desi gn and drawing, complete in all respects inclusive of cost of all labour, materials, carriages, excavation and refilling, curing etc ., as per specifications and directions of the Engineer-in-Charge.

265

636191

-

... More
AC interference survey

39

593640

-

... More
3" SWMG ANSI 600#

20

7150

-

... More
Supply of pre-fabricated printed KM markers for OFC & HDPE as per tender specifications

100

291109

-

... More
Installation of Transition Pits at building entry points as per tender specifications, drawings and directions of Engineer-in-charge/ Site Engineer )

222

2096159

-

... More
Centering and shuttering including strutting, propping etc. and removal of form for all heights :

-

-

-

... More
Supplying all labour, materials, tools, chemicals, spray pumps etc. for making pre-constructional anti-termite treatment & creating a continuous chemical barrier under & all round the column pits, wall trenches, top surface of plinth filling, junction of wall & fl oor, along the exterior perimeter of the building, complete in all respects inclusive of cost of all labour, materials, tools, tackl es etc. as per drawings, specifications and direction of Site Engineer. [Note: Total plinth area of the building shall be measured for payment].

356

117685

-

... More
Filling the excavated earth to required grade, level & profile in low lying areas including watering, ramming, compacting at optimum moisture content to 90% of Proctor's density consolidation by rolling with 8 to 10 tonne power roller in layers not exceeding 20 c m thickness, including clearing the area by cutting of shrubs, bushes, grass, vegetation, debris etc. stacking and disposing out of plot area to an unobjectional area as directed by Engineer-in-Charge complete in all respects inclusive of cost of all labour, mate rials, tools, tackles etc. as per drawings, specifications and direction of the Engineer-in-Charge.

1746

374270

-

1000

216317

-

... More
3", 150#/300#, F/F

4

21579

-

... More
5 Pair Armoured PIJF Underground Telephone Cable as per specifications

400

52023

-

... More
Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using coarse aggregate as well as fine aggregate derived from natural sources and cement content as per approved design mix, manufactured in fully automatic batch ing plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site of laying , ex cluding the cost of centering, shuttering finishing and reinforcement, including cost of admixtures in recommended proportions as pe r IS:9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per directions of the Engineer-in-Charge. [Note : Cement content considered in this item is @ 330 kg/cum. Excess/ less cement used as per design m ix is payable/ recoverable separately] :

-

-

-

... More
8"x ANSI 150# HOV F/F API 600 Gate Valve

2

58848

-

... More
6.625"

86

725582

-

... More
6" 300# 45 deg LR Bend

4

2256

-

... More
1" WNRF 600#

35

25688

-

... More
1:1.5:3 [1 cement : 1.5 coarse sand (Zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived fr om natural sources]

28

343126

-

205

230593

-

... More
For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittin gs wherever required including the cost of EPDM rubber/ neoprene gasket required. [Note: Fittings shall be paid for separately] :

-

-

-

... More
Conducting " Coating-Resistance Survey" for calculation of specific coating resistance of the pipeline in ohms.sq.m. along the entir e pipeline and submitting the report in hard as well as soft copy as per Specification / approved procedure and directions of Site E ngineer / Engineer-in-Charge.

-

-

-

... More
With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works.

5

333

-

... More
Supply and delivery of BS 5351 / ISO 17292 Ball valves for use in process piping at respective stations as per Station wise Break up of material supply and as per technical specifications from approved vendors specified in tender document

-

-

-

... More
Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thi ckness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc . as per directions of the Engineer-in-Charge. [Notes: (1) Length of finished kerb edging shall be measured for payment. (2) Precast C.C. kerb stones shall be approved by the Engineer-in-Charge.]

34

375022

-

... More
1:3:6 (1 cement : 3 coarse sand (Zone-III) derived from natural sources : 6 graded stone aggregate 40 mm nominal size derived from n atural sources)

9

72605

-

... More
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wa ll surface to prepare the surface even and smooth complete.

1512

229264

-

... More
Fasteners for Flanges 3" x 300# (0.75" Dia. X 4.75" Length)

80

7835

-

... More
450 mm diameter piles

2

4756

-

... More
4", 150#/300#, F/F

20

143889

-

... More
1" x 1" 300# x300# F/F TRV

15

250986

-

... More
Beyond 60 cm girth upto and including 120 cm girth

40

89249

-

... More
8" NB Piping

1

7198

-

... More
FINISHING :

-

-

-

... More
On steel work

5

1249

-

... More
Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer's sp ecification. [Note: Unit "KG" shall mean "PER KG PER 50 KG OF CEMENT"].

167

12436

-

... More
4" BLRF 600#

10

28390

-

... More
12" NB Pipe Joints RT

2

6152

-

... More
Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter lock ing metal grid of hot dipped galvanized steel sections (galvanized @ 120 grams/sq.m., both side inclusive) consisting of main 'T' ru nner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross 'T' of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main 'T' at 6 00 mm center to center to form a grid of 1200x600 mm and secondary cross 'T' of length 600 mm and size 24x25 mm made of 0.30 mm thic k (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/ making, opening for services like dif fusers, grills, light fittings, fixtures, smoke detectors etc. Main 'T' runners to be suspended from ceiling using G.I. slotted clea ts of size 27x37x25x1.6 mm fixed to ceiling with 12.5 mm dia. and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanis ed butterfly level clips of size 85x30x0.8 mm spaced at 1200 mm center to center along main 'T', bottom exposed width of 24 mm of al l 'T'-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as direct ed by the Engineer-in-Charge :

-

-

-

... More
Providing and fixing 10 mm thick acid and/or alkali resistant tiles of approved make & colour using acid and/or alkali resisting mor tar bedding and filling joints with acid and/or alkali resisting cement as per IS:4457, all complete as per specifcations and direct ions of the Engineer-in-Charge :

-

-

-

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :

-

-

-

... More
Piping Modification: Carrying out modification in already fabricated and/ or erected pipe due to change in drawing or as required by site condition, taking delivery of pipe, pipe fittings, steel flanges, spiral wound metallic gaskets & fasteners from designated l ocation within station premises, transporting the same to site, cutting of pipe and / or weld joint , edge preparation, bending, lin ing up, welding and installing pipes and pipe fittings, flanges, elbows, equal and reducing outlet tees, concentric/eccentric reduce rs, y-type strainers, drain funnels, vent pipes and tapping for instruments such as pressure gauges, thermal relief valves, thermowe lls etc., installing above ground at all elevations connecting with equipment nozzles, valves, vessels, in line instruments etc., we lded and threaded pipe line of different pressure ratings, flushing pipes by water after cleaning by compressed air, hydrostatic tes ting of each section to the specified pressure, draining the water, tie-in, final cleaning-up and dispoal of wastes and surpluses in cluding providing all inputs such as labour, material, equipments and consumables necessary to perform the work (other than those sp ecifically under taken by the owner in this contract) and completing the work in all respects in accordance with the drawings, speci fications and instructions of Site Engineer / EIC. (Item is to be operated upon approval of SIte Enginner, Item covers only modifica tion / rework jobs.)

-

-

-

... More
Construction of shallow foundation with M20 grade concrete for the highmast considering the safe soil bearing capacity at site as 10 T/sqmtr at 2 metre depth complete with all materials and labour as per instruction of Site Engineer/EIC. Design of foundation shall be provided by IOCL. Piling work if required as per soil strata in foundation of high mast is not covered in this scope of work and shall be taken up separately : For 30 M Height High Mast Tower

1

228386

-

... More
"LT Panel: Erection, installation including transportation from owner desginated location, testing and commissioning of 415 V, owner supplied power-control- centres, motor control centres, soft starters, APFC panel etc. assembling as required, installation on the already ma de foundation channels, aligning, levelling, grouting, assembling, making all the inter connections /outgoing/incoming power & contr ol cable/ bus duct connection/interconnection with existing panel, if required, including making holes for cable entries as required as per drawing, specifications and directions of the Site Engineer/Engineer-in-Charge including cost of all materials, tools labour etc. complete in all respect including termination of all power, control cables, installation of thermistor controller, internal wi ring, earthing of LT panels, supply of cable glands etc.complete as per cable schedule, drawings etc.: "

-

-

-

... More
Transmitter (intrinsically safe) as per specification including 5 m suitable cable for connection with ER probe.

1

337486

-

... More
Providing and fixing aluminium tubular handle bar 32 mm outer dia, 3.0 mm thick & 2100 mm long with SS screws etc .complete as per d irections of the Engineer-in-Charge :

-

-

-

... More
Providing & fixing 6mm thick, copper back finish, looking mirror of required size, made of float sheet glass of best quality & appro ved make, over 12mm thick marine board fixed to rawl plug with round head screws & washers including teakwood beading with melamine polish all around, complete in all respects inclusive of cost of all materials, labour, tools, tackles etc. as per specifications an d directions of the Engineer-in-Charge.

1

3461

-

... More
Providing and laying Burnt Terracota Tiles 12 mm thick for facia, over walls, sloping RCC Roofs etc. at all levels and locations lai d over and including a backing coat of 15 mm thick cement mortar (1 cement : 3 sand) and joints filled with coloured cement of same colour as tiles complete in all respects inclusive of cost of all labour, materials, tools, tackles etc. as per specifications and d irections of the Engineer-in-Charge.

169

379089

-

... More
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fille ts, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering , shuttering, finishing and reinforcement, with :

-

-

-

... More
TANK FOUNDATION WORKS :

-

-

-

... More
Brick work with common burnt clay F.P.S. (non-modular) bricks of class designation 7.5 in superstructure above plinth level up to fl oor V level in all shapes and sizes in :

-

-

-

... More
1" BLRF 600#

4

1359

-

... More
Installation of High Mast Tower(s) as per technical specification -

-

-

-

... More
Providing and fixing ISI marked flush door shutters conforming to IS:2202 (Part I) non-decorative type, core of block board construc tion with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face vene ers on both faces of shutters :

-

-

-

... More
Supply of 415V indoor type Low Voltage switchboard complete with all accessories and spares as per technical specifications, data sh eet and equipment details (Attachment-5 &6) as below:

-

-

-

... More
Providing and fixing rectangular high density polyethylene water storage loft tank with cover (Ref. Make: SINTEX or approved equival ent), conforming to ISI:12701, colour of opaque white or as approved by the Engineer-in-Charge. The rate includes making necessary h oles for inlet, outlet & overflow pipes. The base support including fittings & fixtures for tank shall be paid separately.

50

579

-

... More
"Above ground internal epoxy coated pipe for Fire Water Services: (with internal epoxy coating at welding joints, fittings and flang es) Taking delivery of internal epoxy coated pipes, pipe fittings, steel flanges, spiral wound metallic gaskets & fasteners from d esignated location within station premises, transporting the same to site, fabrication and erection of above ground piping including cutting, edge preparation, bending, threading, lining up, welding and installing pipes and pipe fittings, flanges, elbows, equal and reducing outlet tees, concentric/eccentric reducers, y-type strainers, drain funnels, vent pipes and tapping for instruments suc h as pressure gauges, thermal relief valves, thermowells etc., installing above ground at all elevations connecting with equ ipment nozzles, valves, vessels, in line instruments etc., welded and threaded pipe line of different pressure ratings, flushing pip es by water after cleaning by compressed air, hydrostatic testing of each section to the specified pressure, draining the water, tie -in, final cleaning-up and disposal of wastes and surpluses including providing all inputs such as labour, material, equipments and consumables necessary to perform the work (other than those specifically under taken by the owner in this contract).The scope shall also include cleaning of internal surface of pipes conforming to SSPC SP-10 at all location where coating has been distroyed due to welding and repairing the internal surface by application of 2-pack cold cured Isophthalic polyster acrylic co-polymer glass flake f illed /Liquid epoxy / Equivalent with coating of thickness 700-1000 Microns. Internal coating shall be done at the inner surface of pipe ends, Flanges, pipe fittings, valves, etc so that the internal surface of piping is not directly exposed to water, and completi ng the work in all respects in accordance with the drawings, specifications and instructions of Site Engineer / EIC. Thickness and G rade mentioned in the item are for reference only and may vary. Payment shall be based on OD. "

-

-

-

... More
WATER SUPPLY :

-

-

-

... More
Making Khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggr egate of 20 mm nominal size) over P.V.C. sheet 1 m x 1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse s and) and a coat of neat cement, rounding the edges and making and finishing the outlet complete.

11

3535

-

... More
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in d epth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5m.

5471

1582376

-

... More
1" to 3/4" reducers

15

5218

-

... More
Fasteners for Flanges 2" x 300# (0.625" Dia. X 4.75" Length) - extended stud length for flanges with spectacle blind

16

1491

-

... More
Filling the excavated earth to required grade, level & profile in low lying areas including watering, ramming, compacting at optimum moisture content to 90% of Proctor's density consolidation by rolling with 8 to 10 tonne power roller in layers not exceeding 20 c m thickness, including clearing the area by cutting of shrubs, bushes, grass, vegetation, debris etc. stacking and disposing out of plot area to an unobjectional area as directed by Engineer-in-Charge complete in all respects inclusive of cost of all labour, mate rials, tools, tackles etc. as per drawings, specifications and direction of the Engineer-in-Charge.

51

10932

-

... More
Supply of Valves at respective stations as per technical specifications from approved vendors in the tender document - Globe Valves

-

-

-

... More
Providing and fixing ceramic glazed floor tiles of first quality conforming to IS:15622 (thickness to be specified by the manufactur er) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by the Engineer-in-Charge i n skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cem ent slurry @ 3.3 Kg/sq.m. including pointing in white cement mixed with pigment of matching shade complete.

49

59872

-

... More
Fire Hose Box for keeping 2 Nos. of 15 M Type B delivery hose and one no. jet nozzle

10

62245

-

... More
Extra for providing and placing in position 2 Nos. 6 mm dia. M.S. bars at every third course of half brick masonry.

22

2320

-

... More
"AC point wiring: Point wiring for power plug point with 4 sq.mm stranded PVC insulated copper wire including earthing the third pin with 2.5 sq. mm c opper insulated earthing wire complete with supply and fixing of recessed mounted industrial type 3 pin 32 A metal clad socket and plug, 20A MCB (Motor duty) housed in a 16 gauge M.S. Box."

9

36694

-

... More
INSTALLATION OF JUNCTION BOX/ PUSH BUTTON STATION - for MOV/ROSOV: Installation of non-flame proof junction box, explosion proof / flame proof junction boxes, Push button stations for MOV/ROSOV for marshalling of control cables, terminating the cables at field a nd control panel end, mounting the junction boxes/Push button station, connecting to earthing grid by supplying and installing all t he required materials such as supporting structure, canopy, cable gland hood, cement concrete, painting, GI wire etc. (excluding sup ply of the Junction Boxes/Push button station) in all respects complete as per specifications, drawings and direction of site Engine er including supply of suitable size non-flame proof cable glands at Control Panel end and the cost of labour,tools, materials, glan ding, ferruling etc. complete in all respects.

22

152008

-

... More
Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thi ckness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc . as per directions of the Engineer-in-Charge. [Notes: (1) Length of finished kerb edging shall be measured for payment. (2) Precast C.C. kerb stones shall be approved by the Engineer-in-Charge.]

25

275751

-

... More
25 mm nominal bore

5

3273

-

... More
Area of slab over 0.50 sqm

1

5277

-

... More
Flooding the ground with water including making kiaries and dismantling the same.

50

146

-

... More
1:1.5:3 [1 cement : 1.5 coarse sand (Zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived fr om natural sources]

890

10906516

-

... More
CSW & ML Instrumentation

-

-

-

... More
32 mm diameter

3

399

-

... More
TANK FOUNDATION WORKS :

-

-

-

... More
Providing, laying, spreading and compacting graded stone aggregate (size range 53 mm to 0.075 mm) to wet mix macadam (WMM) specifica tion including premixing the material with water at OMC in for all leads & lifts, laying in uniform layers with mechanical paverfini sher in sub-base/ base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achieve the desired density, complete as per specifications and directions of the Engineer-in-Charge.

30

104348

-

... More
Bend- 87.5 Degrees (110 mm)

22

3761

-

... More
ROAD WORK :

-

-

-

... More
32 mm nominal dia pipes

45

24514

-

... More
4" NB Pipe Joints RT

430

615983

-

... More
Polyester powder coated (Minimum thickness 50 micron) aluminium tubular handle bar

20

15162

-

... More
6" NB - Single Cut Joint

1

7382

-

... More
60mm thick Cement Concrete paver block of M-35 grade with approved colour, design & pattern.

2700

3145665

-

... More
10" x 4" ANSI 150# Un Equal Tee

15

149405

-

... More
35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws

9

22360

-

... More
2" SWMG ANSI 300#

30

4956

-

... More
6"X4" x Concentric Reducer X 300#

6

12843

-

... More
REINFORCED CEMENT CONCRETE :

-

-

-

... More
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber/ neoprene gasket et c. complete as per the architectural drawings and directions of the Engineer-in-Charge. [Note: Cost of aluminium snap beading shall be paid in basic item] :

-

-

-

... More
Primary Packing for Hollow Plug Assembly

1

851

-

... More
Supply of Flameproof & weatherproof CJB with accessories for distribution of current among pipelines as per technical specification.

4

96635

-

... More
Power cables LT : OD upto 20 mm

34

187620

-

... More
Fasteners for Flanges 3" x 600# (0.750" Dia. X 5.50" Length)

80

11044

-

... More
First Aid Box with Snake serum

1

2296

-

... More
10" SORF 150#

125

455037

-

... More
4" SORF 150#

40

37004

-

... More
Single half stall urinal with 5 litre P.V.C. automatic flushing cistern

5

61632

-

... More
Stainless steel liquid soap container (spring loaded push type) with lid and brackets fixed to P.V.C. cleats with C.P. brass screws, etc.

5

13231

-

... More
SERVICES

-

-

-

... More
Cement concrete prepared with batch mixing machine

150

1728815

-

... More
Providing and fixing first quality ceramic glazed wall tiles conforming to IS:15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by the Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey ce ment slurry @ 3.3 Kg/sq.m., including pointing in white cement mixed with pigment of matching shade complete.

94

127532

-

... More
INSTALLATION OF DPT: Installation, assistance in testing and commissioning of Differential Pressure Transmitter (DPT) as per the dir ections of Engineer in-charge/ Site engineer and drawings.

4

69531

-

... More
6.625"

2360

18101200

-

... More
1:3:6 [1 cement : 3 coarse sand (Zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from n atural sources]

6

49453

-

... More
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :

-

-

-

... More
Supply, installation and testing of Lightning arrestor on top of the MOV buiding or MOV CP buiding for diverting lightning surges to the ground. The work shall include supply of 4 Meter long copper lightning arrestor with 5 spronged phenyl rod base plate etc. comp lete with necessary insulators including supply and fixing of 50 x 6 mm GI earthing strip of required length and connection to the m ain earthing grid.

12

225433

-

... More
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishi ng and reinforcement - All work up to plinth level :

-

-

-

... More
Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete :

-

-

-

... More
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wa ll surface to prepare the surface even and smooth complete.

4297

651554

-

... More
"Double Cut Joint Hook-up: Cutting (Hot/ Cold cutting) of portion of existing piping upto and including a length of 500 mm, trimming , grinding, bevelling the edges, adding spool piece of required length / tee and the corresponding pipe size, thickness, adjoining a nd welding both the ends including supply of all inputs such as labour, materials, equipment, consumables etc. necessary to perform and complete the work in all respect as per specification and instruction of the Site Engineer / EIC. Note: The job also include evacuation of product from the piping section after isolating the section and flushing with water and its disposal."

-

-

-

... More
Fasteners for Flanges 2" x 600# (0.625" Dia. X 4.75" Length)

1320

152644

-

... More
100 mm

195

406236

-

... More
2"x ANSI 300# F/F BS-1873 GLOBE Valve

1

21984

-

... More
CSW & ML OFC

-

-

-

... More
Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.

77

198033

-

... More
Suspended floors, roofs, landings, balconies and access platform

436

397909

-

... More
Supply of Valves at respective stations as per technical specifications from approved vendors in the tender document -FOR FIRE WATER NETWORK

-

-

-

... More
Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.

612

491039

-

... More
8" SWMG ANSI 600#

2

1902

-

... More
9 kg DCP Extinguisher

25

130921

-

... More
6.625"

86

626131

-

... More
2"x ANSI 600# F/F API 6D SCV

2

56972

-

... More
Mobilisation/ demobilisation of pigging tools, tackles, consumables, accessories and personnel by contractor at work site including magnetic pig, electronic geometry pig, pig tracking device, preparation and cleaning of the complete mainline / Mainline sections including HDD sections under this tender (but excluding HDD crossings not included under the scope of this tender and to be executed by separate agency) by running series of pigs for cleaning the line from debris, water & making it dry for launching calliper pigs, running of magnetic pig for cleaning of ferrous residue, launching and receiving the electronic & standard calliper pigs, including pig tracking at 5 to 10 km interval, data retrieval, interpretation of data and submission of reports in the form acceptable to the Owner, including rectification of defects observed from calliper survey, including supply of all labour, materials, equipment & instruments, calliper pigs, fabrication of launching & receiving barrels, all complete for ascertaining the geometry of the pipeline.

-

-

-

... More
Cement mortar 1:3 (1 cement :3 coarse sand)

22

27713

-

... More
Taking delivery of MOVs for mainline from Owner's stockpile/ godown, preparation of pup pieces of specified length from owner supplied pipes of higher wall thickness, welding of pup pieces to both sides of valves, providing instrument tappings in MOVs, hydrostatically testing the valves & installing at designated locations on the mainline in accordance with the specifications and drawings, welding & 100% radiography of weld joints, repair of weld joints etc., complete in all respect including all works and material in foundation, RCC underground valve supports etc., including PU Coating of underground portions and painting of overground portions / valve enclosure etc. with aluminium paint over a coat of primer, and including supply of all materials (other than those specifically undertaken to be supplied by the Owner), consumables & inputs complete as per specifications, drawings & instructions of Site Engineer / Engineer-in-Charge.

-

-

-

... More
Fasteners for Flanges 2" x 600# (0.625" Dia. X 5.75" Length) - extended stud length for flanges with spectacle blind

64

8835

-

... More
Polyester powder coated aluminium (Minimum thickness of polyester powder coating 50 micron)

418

305458

-

... More
2", 150#/300#, F/F

2

5994

-

... More
Supply & installation of MAGNETIC PROXIMITY SWITCH with suitable junction box for termination of leads/cable for extending contact t o control system for unauthorised entry of building / MOV fencing.

24

459479

-

... More
4" X 150# High Volume Long Range Foam Monitor 750 GPM capacity stand post type

4

1571278

-

... More
10" NB Pipe Joints RT

240

628137

-

... More
Copper Cable size 2cx6 sq.mm Armoured

1350

269647

-

... More
"Cable Marker Supply, erection and installation of MS cable markers; including excavation,installation of the markers,cement concrete grouting, back-filling etc. required as per drawings, specifications and directions of the Site Engineer,including the cost of all ma terials, labour,tools etc. complete in all respects as per the directions of Site Engineer / Engineer-in-Charge."

-

-

-

... More
1" Cable Glands

50

15585

-

... More
In Ordinary rock

36

16708

-

... More
8 way junction box with 8 cable entries (1 x 1" & 7 x 3/4") at bottom & 20 nos. terminals.

3

41617

-

... More
4.5 kg CO2 Extinguisher

10

88948

-

... More
Constructing percolation pit of size 3.0m diameter and 2.0m deep, filled with 40 mm size brick ballast including providing suitable pre-cast RCC covers with lifting lugs, laying of 150mm diameter x 5.0m long U.P.V.C. pipe embedded in pit/ outlet pipe all complete as per specification and directions of the Engineer-in-Charge.

5

513558

-

... More
Automatic type Cathodic Protection Power Supply Module (CPPSM) cum Cathodic Protection Transformer Rectifier (CPTR) unit with 48 V D C & 230 V AC input and 25 V, 25 A DC output along with DC-DC converter & TRU with built in digital data logger having GSM mobile pho ne connectivity, SCADA linkage and data downloading facilities for data downloading/monitoring,complete as an intergral unit, as per specifications and of approved make

2

884828

-

... More
"Single Cut Joint Hook-up: Cutting (Hot/ Cold cutting) of portion of existing piping, trimming, grinding, bevelling the edges, align ing with/ without addition of spool piece, welding the joint including supply of all inputs such as labour, materials, equipment, co nsumables etc. necessary to perform and complete the work in all respect as per specification and instruction of the Site Engineer / EIC. Note: The job also include evacuation of product from the piping section after isolating the section and flushing with water and its disposal."

-

-

-

... More
6.625" in Rocky Soil

200

5994400

-

... More
Providing and placing on terrace (at all floor levels) polyethylene water storage tank (Ref. Make: SINTEX or approved equivalent), I S:12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but with out fittings and the base support for tank.

2000

23175

-

... More
1:6 (1 cement : 6 fine sand)

6377

2459199

-

... More
2" 300# 90 deg LR Bend

10

11953

-

... More
1:2:4 [1 cement : 2 coarse sand (Zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from n atural sources]

2

17879

-

... More
3"x ANSI 600# HOV F/F API 6D Ball

4

158771

-

... More
6.625"

6

406250

-

... More
2" SWMG ANSI 600#

250

59590

-

... More
12" x 10" ANSI 150# Un Equal Tee

4

36301

-

... More
FINISHING :

-

-

-

... More
Supply of cable glands - flame proof and weather proof including EP/WO certificates

-

-

-

... More
6"x4" x 300# Unequal Tee

2

8767

-

... More
EARTHWORK :

-

-

-

... More
STEEL WORK :

-

-

-

... More
Single Tee with door (110x110x110 mm)

11

2944

-

... More
Providing gola 75x75 mm (in 75x75 mm deep chase) in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and do wn gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design.

225

70293

-

... More
Supply, erection and installation of GI Pipe of 100 mm nominal bore medium Class B as per IS1239 subject to owner's approval including the supply & installation of all necessary pipe fittings such as bends, sockets, elbows, tees etc. bending, threading, clamping, plugs, packings, bushing etc. as required for sub ducting HDPE duct as per directions of Engineer-in-charge/ Site Engineer including cost of all labour, tools, materials complete in all respects.

80

129373

-

... More
Supply and delivery of Fire Fighting Equipment at respective stations as per Station wise Break up of material supply and as per tec hnical specifications from approved vendors specified in tender document

-

-

-

... More
Providing and fixing factory made precast RCC perforated drain covers, having concrete of strength not less than M-25, of size 1000x 450x50 mm, reinforced with 8 mm dia four nos longitudinal & 9 nos. cross sectional T.M.T. hoop bars, including providing 50 mm dia p erforations @ 100 to 125 mm c/c, including providing edge binding with M.S. flats of size 50 mm x 1.6 mm complete, all as per direct ions of the Engineer-in-Charge.

20

31889

-

... More
ACDB Panel: Supply of ACDB Panel (IP-4X Degree of Protection) with base frame, having incomers and feeders, suitable for 03 phase DG supply, of approved make, as indicated in technical specifications, complete in all respects.

5

1848800

-

... More
Magnesium Anode : Supply, Installation , testing and commisioning of Magnesium anode (minimum 5 Kg each) including its tail cable o f size of 1c x 10 sq.mm. XLPE/ PVC insulated stranded copper cable of total length 10 meter including PVC cap, special back-fill mat erial ( filled in cotton sack) with sealing compound complete in all respect including its excavations, back filling etc. as per spe cifications and drawings. The work complete in all respect shall include supply of all labour , tools etc. and shall be carried out as per the directions of the EIC/ Site Engineer and as per AFC drawings.

-

-

-

... More
2" NB - Single Cut Joint

2

6239

-

... More
FLOORING :

-

-

-

... More
Constructing percolation pit of size 3.0m diameter and 2.0m deep, filled with 40 mm size brick ballast including providing suitable pre-cast RCC covers with lifting lugs, laying of 150mm diameter x 5.0m long U.P.V.C. pipe embedded in pit/ outlet pipe all complete as per specification and directions of the Engineer-in-Charge.

1

102711

-

... More
Providing and laying seal coat over prepared surface of road with bitumen heated in bitumen boiler fitted with the spray set sprayin g using 98 kg of bitumen of grade VG-10 and blinding surface with 0.90 cum of stone aggregate of 6.7 mm size (Passing 11.2 mm sieve and retained on 2.36 mm sieve) per 100 sqm of road surface, including rolling and finishing with power road roller all complete. [No te: This item to be operated only with the prior approval of the Engineer-in-Charge].

250

32638

-

... More
Holes 60 cm diameter and 60 cm deep

10

615

-

... More
C.P. brass double coat hook (Ref. Make: JAQUAR, Model: Cat. No. 1161 or approved equivalent).

5

6743

-

... More
TLP type "A" , flame proof & weather proof as per specifications and drawing (With inbuilt provision of Voltmeter & pushbutton for P SP Measurment)

4

90891

-

... More
Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per the directions of Engineer-in-Charge. [Notes: (1) Dismantling shall be allowed during day shift only & prior permission for the same shall be obta ined. (2) Providing of necessary covers/ barricades around the work area shall be done prior to dismantling operations] :

-

-

-

... More
Flexible Pipe :

-

-

-

... More
3"X1" x Concentric Reducer X 300#

2

840

-

... More
Supplying, fabricating and fixing M.S. structural steel work made of joists, tubes, pipes, channels, angles, plates, flats, bars etc., for struts, chain link fencing posts as per drawing including gate, ladders, safety grills, walkways, collapsible gate, signboards, supports for cable trench, cable racks, cable tray support, chequered plates, push button control posts, supporting structures, making slots for barbed line, wire hoisting, placing in position, embedding in concrete, applying two coats of epoxy paint "EPILUX 155" High Build Enamel over a coat of EPILUX 610 Primer of M/s Berger or any other approved equivalent make as per manufacturer's recommendation, complete in all respect including cutting to required size welding of joints, fixing anchor plates,bolts, theading, nuts, washers, sleeves etc. and necessary lettering of approved pattern on main gate, signboards etc.complete in all respects inclusive of cost of all labour, materials, tools, tackles etc. as per drawings, specifications and directions of the Engineer-in-Charge. (excluding the cost of concrete work)..

10.65

1585474

-

... More
4" BLRF 300#

2

3950

-

... More
PMCC (MVP- IOCL-Goindwal-01)

1

2626940

-

... More
4.50" OD x 0.237" WT ASTM A 333 Gr. 6 PIPE

320

1103724

-

... More
3" 300# 90 deg LR Bend

40

81042

-

... More
Supplying, fabricating and fixing M.S. structural steel work made of joists, tubes, pipes, channels, angles, plates, flats, bars etc., for struts, chain link fencing posts as per drawing including gate, ladders, safety grills, walkways, collapsible gate, signboards, supports for cable trench, cable racks, cable tray support, chequered plates, push button control posts, supporting structures, making slots for barbed line, wire hoisting, placing in position, embedding in concrete, applying two coats of epoxy paint "EPILUX 155" High Build Enamel over a coat of EPILUX 610 Primer of M/s Berger or any other approved equivalent make as per manufacturer's recommendation, complete in all respect including cutting to required size welding of joints, fixing anchor plates,bolts, theading, nuts, washers, sleeves etc. and necessary lettering of approved pattern on main gate, signboards etc.complete in all respects inclusive of cost of all labour, materials, tools, tackles etc. as per drawings, specifications and directions of the Engineer-in-Charge. (excluding the cost of concrete work).

3

446612

-

... More
Up to 5 mm depth and 5 mm width

307

50571

-

... More
Supply of Joint pit markers for OFC joint locations as per tender specifications

243

948736

-

... More
Supply of Valves at respective stations as per technical specifications from approved vendors in the tender document - Swing Check V alves

-

-

-

... More
12", 150#/300#, F/F

1

21582

-

... More
Installation of Manual High Volume Long Range Foam Monitor 750 GPM capacity stand post type with inlet flange of 4" X 150# MHVLR

4

20607

-

... More
Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.

6

15431

-

... More
Preparation and consolidation of sub-grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the s ub grade and disposal of surplus earth with lead up to 50 metres.

1458

300939

-

... More
15 mm nominal bore

5

4074

-

... More
FINISHING :

-

-

-

... More
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :

-

-

-

... More
Providing and laying Burnt Terracota Tiles 12 mm thick for facia, over walls, sloping RCC Roofs etc. at all levels and locations lai d over and including a backing coat of 15 mm thick cement mortar (1 cement : 3 sand) and joints filled with coloured cement of same colour as tiles complete in all respects inclusive of cost of all labour, materials, tools, tackles etc. as per specifications and d irections of the Engineer-in-Charge.

10

22431

-

... More
CONCRETE WORK :

-

-

-

... More
8" ANSI 150# Equal Tee

2

6636

-

... More
Composite-CSW Mechanical

-

-

-

... More
Installation of GLOBE VALVE/CONTROL VALVE/MOTORIZED GLOBE VALVE/ROV/PLUG VALVE: Taking delivery of valves of all types and pressure rating from the designated location within station premises, transporting the same to site, erecting above ground on preconstructed foundations or underground including earth work in excavation and filling for under ground valves at elevations specified in the dra wings, priming and painting of above ground valves, PU Painting of under ground portions (if applicable) or flood coating and wrappi ng of under ground portions (if applicable) including all inputs, labour, material and consumable (other than those specifically un dertaken to be supplied by the owner) and completing the work in all respects in accordance with the drawings, manufacturer's instal lation instructions and specifications and instructions of the Site Engineer / EIC.

-

-

-

... More
AIR CONDITIONER SPLIT TYPE - Supply & Installation of 1.8T Split Type five star BEE rated ACs (Daiiken / Hitachi / Carrier) along with 5KVA Voltage Stablizer & MS stand for outdoor unit, refregerant piping, drain piping complete as per instruction of EIC / Site Engineer

2

254956

-

... More
Services-CSW Mechanical

-

-

-

... More
Trenching in ordinary soil up to a depth of 60 cm including removal and stacking of serviceable materials and then disposing of surp lus soil, by spreading and neatly levelling within a lead of 50 m and making up the trenched area to proper levels by filling with e arth or earth mixed with sludge or/ and manure before and after flooding trench with water. [Note: The rate is excluding cost of imp orted earth, sludge or manure].

4

423

-

... More
3 NPS (3.5" OD x 0.216"/ 0.438" WT) ASTM A106/ A333/ A53 Pipe

100

295708

-

... More
50 to 100 mm average compacted thickness with bitumen of grade VG-30 @ 5% (percentage by weight of total mix) and lime filler @ 2% ( percentage by weight of Aggregate) prepared in Batch Type Hot Mix Plant of 100-120 TPH capacity.

19

251807

-

... More
Copper cable as per specifications - 100 sq. mm

320

768955

-

... More
Providing gola 75x75 mm (in 75x75 mm deep chase) in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and do wn gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design.

102

31866

-

... More
Extinguisher box for 9 kg DCP Extinguishers

10

59542

-

... More
8" NB - Mitre Bend (angle more than 45° & up to 90°)

1

18803

-

... More
Cement mortar 1:4 (1 cement : 4 coarse sand)

93

94757

-

... More
Suspended type LED light fittings with LEDs: Supply and fixing of surface mounted weather proof LED light fitting of PHILLIPS or equ ivalent approved make with LED of 42 W or more, having 2950 lumens or more output complete with all accessories such as LED module, driver, optics, thermal sink, connector blocks etc including installation with LED of approved make.

81

975091

-

... More
12"x ANSI 150# HOV F/F API 600 Gate Valve

1

64887

-

... More
8"x2" X 150# Weld-o-let

2

4387

-

... More
Supply and delivery of API 6D Ball valves for use in process piping at respective stations as per Station wise Break up of material supply and as per technical specifications from approved vendors specified in tender document

-

-

-

... More
Providing and making Construction/ Contraction joint by mechanically cutting 12mm x 25mm deep groove and filling with bituminous sea ling compound including cleaning etc. complete as per drawing, specifications and directions of the Engineer-in-Charge.

678

480320

-

... More
100x100 mm size P-type

3

9113

-

... More
CONCRETE WORK :

-

-

-

... More
32 mm diameter

10

1331

-

... More
Supplying, providing and filling soft soil in trenches at Seismic Fault location crossing or running parallel to pipeline (including additional 500 mm deep & 200/300 mm wide trenching) around mainline pipe for providing a minimum padding thickness of 500 mm on top as well as at bottom of the mainline pipe(for the complete trench width). Padding materials shall be sand/graded soil/other suitable material containing no gravel, rock, or lumps of hard soil. The graded soil for padding shall pass through sieve size ASTM-10 or ISO-2.00. Acceptable padding shall be placed under the pipeline before its installation and around it after installation, to establish at both sides and on top of the pipe a permanent layer of padding. The thickness of compacted padding shall be at least 150mm. The trench shall be deeper by at least 150mm. The trench shall be evenly and sufficiently padded to keep the pipe, when in place, at least 150mm above the bottom of excavated trench. At seismic fault locations, in addition to the above requirements of padding material, in case the dugout soil is clayey in nature (undrained sheer strength 0.5 T/m2), the local soil shall be replaced by engineered (cohesion less) backfill having angle of friction not more than 27 degrees and the same shall be loosely compacted (unit weight 1.8 T/m3). In case of undrained sheer strength of the dugout soil = 0.5 T/m2 the dugout soil itself can be used as backfill. The trench shall be deeper by at least 500 mm. The trench shall be evenly and sufficiently padded to keep the pipe, when in place, at least 500 mm above the bottom of excavated trench. Acceptable padding shall be placed under the pipeline before its installation and around it after installation, to establish at both sides and on top of the pipe a permanent layer of padding. The thickness of compacted padding shall be at least 500 mm. Supports shall be provided for the pipeline by use of sand/soft soil bags or intermittent transverse berms in the ditch bottom comprising gravel/rock-free material, with a width of 15-20 cm and at an interval of approximately 7 meters. Note: (i) Item to be operated under specific instructions from Engineer-in-Charge. (ii) Cost of additional depth of 500mm & width of 200/300 mm trenching for this item shall be included in this item itself.

-

-

-

... More
1/2" Plugs

30

1286

-

... More
Supply-CSW Mechanical

-

-

-

... More
With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works.

6

400

-

... More
1" ANSI 600# Equal Tee

14

6178

-

... More
Centering and shuttering including strutting, propping etc. and removal of formwork for :

-

-

-

... More
FLP/WP ROTARY SWITCH: Supply, installation, testing & commissioning of Flame proof weather proof ON/OFF Rotary Switch , IP65, LM6, i ncluding including supply & installation of double compression cable glands & flame proof plugs for sealing all spare entries etc., complete in all respects.

6

41696

-

... More
Supply and planting sapling (not less than 45 cm in height and 60 cm centre to centre) of Casurina, Labrum, Gulmohar, Ashokas, Bottl e Palm, Bougenvilla, Hibiscus, Roses or other approved type of variety of plants, watering & maintenance for 30 days minimum complet e in all respects inclusive of cost of all materials, labour, tools, tackles etc. as per specifications and directions of the Engine er-in-Charge.

20

13572

-

... More
1" WNRF 300#

45

19593

-

... More
FLOORING :

-

-

-

... More
1:1.5:3 [1 cement : 1.5 coarse sand (Zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived fr om natural sources]

123

1581455

-

... More
25 mm nominal dia pipes

39

28860

-

... More
6.625"

1000

1368800

-

... More
G.I. Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of G.I. sheet having galvanizing of 100 gms/sq.m. (both sides inclusive) and 20% perforation area with 1.8 mm dia. holes and having NRC (Noise Reduction Coefficient) of 0.5, electro-statically polyester powder coated of thickness 60 microns (minimum), including fa ctory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece.

96

208479

-

... More
100 mm diameter :

-

-

-

... More
Filling the gap in between Aluminium/ Stone/ Wood frame and adjacent RCC/ Brick/ Stone/ Wood/ Ceramic/ Gypsum work by providing weat her/ structural non-sag elastomeric PU sealant over backer rod of approved quality as per architectural drawings and directions of t he Engineer-in-Charge complete, complying to ASTM C920, DIN 18540-F & ISO 11600 :

-

-

-

... More
C.P. Brass (Ref. Make: JAQUAR, Model: Cat. No.-1151 or approved equivalent).

5

3843

-

... More
1:1.5:3 [1 cement : 1.5 coarse sand (Zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived fr om natural sources]

107

1087515

-

... More
Providing and fixing toilet paper holder :

-

-

-

... More
Supply of fully charged CO2 fire extinguishers as per specifications (2 kg capacity as per IS: 2878 latest)

12

60139

-

... More
For 10 Users

5

803329

-

... More
" Dismantling of Structures: Dismantling by opening joints or by gas cutting/ cold cutting (wherever required as per site condition) o f existing steel structural such as support for pipes, pipe fittings, valves, plate forms, walkways, stairways etc. including excava tion work wherever required handling, loading into truck for purpose of weighing, shifting to the designated location within the pum p station premises and handing over, completing the work in all respect as per drawings, instruction of the Site Engineer / EIC "

4

75005

-

... More
GST % for the tender Please select the rate of GST in cell AY13. Rate selected shall be applicable for the entire BoQ.

-

-

-

... More
Beyond 30 cm girth upto and including 60 cm girth

40

20047

-

... More
Thermo-Mechanically Treated bars of grade Fe-500 D or more

152742

16794349

-

... More
4" WNRF 600#

70

226984

-

... More
DIRECTION MARKER

260

2294864

-

... More
Copper Cable size 2cx70 sq.mm Armoured

50

33912

-

... More
Supply of Four pin Soil Resistivity Meter with output maximum 80 wattt / upto 200 mA stabilised current output as per technical sp ecification.

1

6436

-

... More
2" BLRF 600#

45

35099

-

... More
4", 600#/900#, F/F

20

159583

-

... More
Providing and fixing double glazed hermetically sealed glazing in aluminium windows, ventilators and partition etc. with 6 mm thick clear float glass both side, having 12 mm air gap, including providing EPDM gasket, perforated aluminium spacers, desiccants, sealan t (both primary and secondary sealant) etc. as per specifications, drawings and directions of the Engineer-in-Charge complete.

30

154281

-

... More
Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar lo cation in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of c ut edges etc. complete.

10

9672

-

... More
ALUMINIUM WORK :

-

-

-

... More
Pipe to Soil potential Readings : Measurement, recording and submission of Pipe to Soil Potential readings by connecting / disconnec ting the Mg anodes (for achieving optimal protection through TLPs) along the entire pipeline and at stations, including preparing an d submiting relative PSP profile and other relevant data pertaining to the cathodic protection of the pipeline, including cost of al l labour, instruments and services rendered. The readings shall be furnished as per the specifications and as per the directions of the Site Engineer/Engineer-in-Charge

85

45594

-

... More
Providing & fixing fly proof wire gauze to windows, clerestory windows & doors with M.S. Flat 15x3 mm and nuts & bolts complete :

-

-

-

... More
Supplying, fitting and fixing punched tape concertina spiral coil of 50 turns per coil having core wire of 2.6 mm diameter made of h igh carbon spring steel of high tensile strength as per IS:4454 (Part-I, Grade-II) having minimum galvanising coating thickness equi valent to 230 grams per square metre and low carbon steel strip of 0.5 mm thickness having a series of barbes punched all along the length on both sides of the strip at regular interval as per IS:513, DD quality having minimum galvanising coating thickness of 12 m icrons. Hardness of tape should be between 137-180 VPN (Victor Penetration Number). The coil should be clipped sufficiently at regul ar intervals. The coil should not be stretched for more than 6.0 m length and the minimum diameter of the coil in the closed conditi on should not be less than 600 mm complete in all respects inclusive of cost of all labour, materials, tools, tackles etc. as per dr awings, specifications and directions of the Engineer-in-Charge.

1000

589162

-

... More
6.625" in Rocky Soil

700

15446200

-

... More
8" SWMG ANSI 150#

25

9676

-

... More
Providing and laying in position bitumen hot sealing compound for expansion joints etc. :

-

-

-

... More
Capacity above 1 KW and upto 2.5 KW

37

149350

-

... More
12" SWMG ANSI 150#

2

1191

-

... More
Polyester powder coated aluminium (Minimum thickness of polyester powder coating 50 micron)

517

316371

-

... More
Fasteners for Flanges 4" x 600# (0.875" Dia. X 6.50" Length)

680

198192

-

... More
24 Port L2 Network Switch with Optical Interfaces as per tender specifications

3

595700

-

... More
External Painting of Piping/ Equipment: Surface preparation of piping, equipment and valves etc. by abrasive blast cleaning or with power wire brush (wherever blast cleaning is not possible) confirming to SA 2.5, making the surface free of dust, grease, mill scale s etc., application of 1 coat x 50-75 microns DFT of Inorganic Zinc Ethyl Slicate Primer, followed by application of sealer coat of 30 micron DFT and intermediate coat of 150 micron DFT with surface tolerant epoxy mastic paint and 2 coats x 50 micron each DFT of Isocynate Aliphatic Poly Urethene (PU) by airless spray, with approved materials, paints, tools, tackles, consulambles, non-consumab les, labour, equipment etc. to complete the job in all respects as per specification and instructions of the Site Engineer / EIC. Th e total DFT shall be minimum 330 microns.

900

1519722

-

... More
White Vitreous China Wash basin size 550x400 mm (Ref. Make: HINDWARE, Model: Cat No.-10010 or equivalent approved) with a pair of 15 mm C.P. brass pillar taps

10

37489

-

... More
6" BLRF 600#

2

12154

-

... More
2.0 kg CO2 Extinguisher

10

70351

-

... More
6.625" in Rocky Soil

10

285560

-

... More
KILOMETER POST

86

781396

-

... More
"Conducting Direct Current Voltage Gradient Survey over the buried line, logging all measurements, to identify / pin point the coat ing defects on pipeline including the cost of all competent manpower, transportation and camping facilities etc. to their employees, materials, test instruments, equipments, consumables etc., required for the survey as per the standard specifications and approved procedures, identification of areas/locations where coating repair is required alongwith suggestion for remedial measures etc. inclu ding the submission of draft reports in 2 sets and incorporation of owner's comments in the draft report and final reports in 3 sets including one soft copy containing the survey results in the graphical as well as tabular forms computerised colour print and compl ete in all respects as per directions of Site Engineer / Engineer-in-Charge. Note : The item includes establishing the coating defect at specified locations by excavation in coordination with mainline contract or, who will arrange to repair the defects."

-

-

-

... More
3.5" OD x 0.216" WT ASTM A 333 Gr. 6 PIPE

300

733488

-

... More
Supplying and laying reinforced cement concrete light duty hume pipe, non pressure type (NP3), centrifugally cast conforming to I.S .458 with 1:3:6 concrete casing at joints as required with necessary slope including excavation, backfilling, supply of collars, jo inting of pipes with stiff mixture of cement mortar in the proportion of 1:2 ( 1 cement: 2 fine sand), testing of joints, complete i n all respects as per specifications, drawing and the direction of the EIC/Site Engineer:

-

-

-

... More
Providing and fixing 75mm diameter P.V.C. pipe (4 Kg/sq.cm) for Weep Holes in Masonry/ RCC wall including providing 230x230x230 mm s ize (approx.) filter using pebles of 40mm & down size in every weep hole on retaining side etc. complete in all respects inclusive o f cost of all materials, labour, tools, tackles etc. as per specifications and directions of the Engineer-in-Charge.

300

109035

-

... More
Transportation (loading and unloading) of Owner supplied unarmoured Optical fibre cable (OFC) to various sites along Right of Way (ROW), pre laying testing of each cable drum for each fibre and taking the OTDR traces, submission of OTDR traces (in hard as well as soft copy) to Engineer-in-charge/ Site Engineer, blowing of OFC through contractor laid HDPE, jointing / splicing of OFC, post installation testing of OFC for each fibre for each drum laid & taking OTDR traces, submission of OTDR traces (in hard as well as soft copy) to Engineer-in-charge/ Site Engineer as per the scope, specifications and directions of Engineer-in-charge/ Site Engineer.

101

3609444

-

... More
6.625" in Normal Soil

390

4417920

-

... More
"Insulating Coupling Erection: Taking delivery and transportation of equipments from designated Centralized warehouse location withi n the state (Details of warehouse given in SCC) and installation of Insulating Couplings of the following sizes and pressure class, at elevations specified in the drawing, checking resistance value by meggar test before and after erection levelling, aligning and c hecking, making welded connections to the piping, coating & wrapping and completing the work in all respects in accordance with the relevant drawings, manufacturer's installation instructions, specifications and instructions of Site Engineer / EIC. "

-

-

-

... More
Hedge Plant/ Ground Cover

8

26

-

... More
Columns, Pillars, Piers, Abutments, Posts and Struts

353

341054

-

... More
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishi ng and reinforcement - All work up to plinth level :

-

-

-

... More
Fine dressing of the ground

50

250

-

... More
Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer's sp ecification. [Note: Unit "KG" shall mean "PER KG PER 50 KG OF CEMENT"].

605

45054

-

... More
Providing and fixing decoratiave special coloured vitreous china clay wall mounted European type Water Closet (Ref. Make: HINDWARE, Model: Cat No.-20028 or equivalent approved) with dual flushing cistern (Ref. Make: HINDWARE, Model: Cat No.-21038 or equivalent app roved) of approved shade including matching shade of plastic seat and lid cover, fittings, connectors, necessary hanging arrangement , rubber buffers etc., including cutting and making good the wall and floors wherever required, making connections to soil/ vent pip e, etc. complete in all respects inclusive of cost of all required fittings, fixtures, materials, labour, tools, tackles etc. as per specifications and directions of the Engineer-in-Charge.

1

28316

-

... More
1" NB Pipe Joints RT

430

253700

-

... More
Supplying and laying flat brick soling in foundation trench, in floors, garages, sumps, etc., with bricks of class designation 50 la id to proper slope, level and grade etc. filling of the joints with sand etc. complete in all respects inclusive of cost of all labo ur, materials, tools, tackles etc. as per drawings, specifications and directions of the Engineer-in-Charge.

36

29541

-

... More
Supply of Surge Arrestors of approved make including required length of cable & as per specifications for protection of insulating couplings

-

-

-

... More
White Vitreous China Wash basin size 550x400 mm (Ref. Make: HINDWARE, Model: Cat No.-10010 or equivalent approved) with a pair of 15 mm C.P. brass pillar taps

2

7497

-

... More
4" 300# Equal Tee-ASTM A420 Gr.WPL6

1

1205

-

... More
Providing and laying Dense Graded Bituminous Macadam using crushed stone aggregates of specified grading, premixed with bituminous b inder and filler, transporting the hot mix to work site by tippers, laying with paver finisher equiped with electronic sensor to the required grade, level and alignment and rolling with smooth wheeled, vibratory and tandem rollers as per specifications to achieve the desired compaction and density, complete as per specificatons and directions of the Engineer-in-Charge :

-

-

-

... More
New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm

153

46741

-

... More
Providing and fixing brass 100mm mortice latch and lock with 6 levers without pair of handles (best make of approved quality) for al uminium doors including necessary cutting and making good etc. complete.

20

12076

-

... More
450 mm dia R.C.C. pipes

34

104046

-

... More
Lintels, beams, plinth beams, girders, bressumers and cantilevers

2805

2039096

-

... More
Providing and laying in position bitumen hot sealing compound for expansion joints etc. :

-

-

-

... More
All works above plinth level upto floor V level

10

123794

-

... More
Constructing Brick Masonary catch pit in cement mortar 1:4 (1 cement : 4 coarse sand) including necessary excavation, 200mm thick fo undation concrete 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 40mm size) and inside and top plastering (15mm thic k) with cement mortar 1:4 (1 cement : 4 coarse sand) finished with a floating coat of neat cement making necessary connections to dr ains inclusive of all labour, material, equipment, etc., all complete as per drawing, specifications and directions of the Engineer -in-Charge :

-

-

-

... More
Water thinnable cement primer

1512

119449

-

... More
GI CABLE TRAY: Supply, installation & fixing of prefabricated perforated GI cable trays with tray cover of width 150 mm, 300 mm, 450 mm & 600 mm as per site requirement for laying of cables with standard rung spacings. Load for support span of 2.5 meter as 30, 60, 75 & 90 (in Kg/Mtr) respectively with concentric static load as 70 Kg at the centre, with materials, labour, tools and tackles, con sumables etc , as per drawings, specification and directions of Site Engineer / Engineer-in-Charge.

17300

3842118

-

... More
Water thinnable cement primer

4297

339467

-

... More
1:4:8 [1 cement : 4 coarse sand (Zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from n atural sources]

438

3339303

-

... More
Installation of RF iD type Electronic Markers as per tender specifications. The job includes configuration & programming of the Electronic markers to write information data as per directions of Engineer-in-charge/ Site Engineer.

255

238150

-

... More
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundations and plinth in :

-

-

-

... More
Laying submerged crossings using pipes with or without concrete sheathing across major water course crossings and providing all works ,labour, inputs and materials/consumable necessary to perform and complete the work in all respects in accordance with the contract, including taking delivery and transportation of Owner-supplied coated pipes to the work site from designated stockpile location, inspection of the coated pipes visually and with holiday detector for defects, arranging all necessary intermediate storage area required thereof till the pipes are installed in permanent position, arranging the required additional land for construction purpose, preparation of site, aligning, bending, lining up and welding the pipe, 100% radiographic inspection of weld joints, coating of field weld joints, holiday detection and repair of coating, hydrotesting (both pre- & post-installation) and replacement of pipes/ defects, excavation of the trench to required depth, as per specifications, in all kinds of soil and conditions including rock trenching and maintenance of trench in all kinds of soil including rocky strata, if any, making bunds for stoppage of water flow, de-watering including installation of well-point system, and laying of the pipeline in approved trench, including de-watering, providing in-situ concreting at coated weld joints to effectively secure the HDPE conduit with mainline pipe, providing "Band IT" make stainless steel (SS) strips / clamps of 3/4" width for tying HDPE conduit with mainline pipe (two strips per pipe length), backfilling and final clean-up, stabilisation of the excavated banks by additional means, disposal of waste and surplus in accordance with the contract, and supply of materials (other than those specifically undertaken to be supplied by the Owner under the contract) necessary for or in the performance of the work or for temporary or permanent incorporation in the works and all other acts, matters and things necessary to complete the pipeline/ crossings in all respects according to the contract and as per directions of Site Engineer/ Engineer-in-Charge. NOTE : I)Depending upon the site condition & location of each submerged crossing, the Engineer-in-Charge, in consultation with the Contractor, shall decide upon the precise operations necessary for the performance of the work to lay the pipeline across the canal/ drain/ rivers and the cost of all such operations necessary shall be deemed to have been included in the rate for this item. II)Profile of drain / canal bed, ground & top of laid pipe shall be established jointly in presence of Owner both before and after laying the crossing, by taking levels with reference to nearby permanent structure. III)The banks of the crossing shall be stabilised and suitable brick/ stone masonry bank protection works shall be carried out for the entire ROW width to prevent bank erosion leading to exposure of the pipeline. The procedure for such measures shall be submitted for Owner's approval prior to execution. IV)Concrete sheathing work for submerged crossings shall be paid for separately under relevant item of Schedule of Rates.

-

-

-

... More
Cement mortar 1:6 (1 cement : 6 coarse sand)

95

770295

-

... More
Supply and delivery of Spectacle Blinds at respective stations as per Station wise Break up of material supply and as per technical specifications from approved vendors specified in tender document

-

-

-

... More
2.5 kg clean agent extinguishers IS 15683 Marked

4

74576

-

... More
Type A (With Ingress Protection IP:55)

91

1687909

-

... More
REINFORCED CEMENT CONCRETE :

-

-

-

... More
Strecher WITH BLANKET

2

12710

-

... More
INSTALLATION OF PT / PS: Installation, assistance in testing and commissioning of Pressure Transmitter (PT) / Pressure Switch (PS) o f various ratings as per the directions of Engineer in-charge/ Site engineer and drawings.

20

231893

-

... More
Flameproof Type DMV (With Ingress Protection IP:55) as per specification

8

383715

-

... More
Kota stone slab flooring 25 mm thick over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigmen t to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse san d) :

27

54464

-

... More
INSTALLATION & TESTING OF SCRAPPER DETECTOR: Installation, assistance in testing and commissioning of Scrapper Detector of various ratings aas per OEM recommandations, vendor drawings, directions of engineer in-charge/site engineer and other approved drawings.

2

15058

-

... More
Construction of open surface drain complete as per drawing including necessary excavation, refilling, disposal of surplus earth, pro viding and laying one layer of flat brick and cement concrete 1:3:6 (150 mm thick) at bottom, lining with brick masonry in cement mo rtar 1:4 (1 cement : 4 coarse sand), plastering exposed surface with 18 mm thick cement mortar 1:4 1:4 (1 cement : 4 coarse sand) wi th a floating coat of neat cement, rounding off corners etc. complete as per specification, drawing and directions of the Engineer-i n-Charge :

-

-

-

... More
Supervision Charges for erection, installation, testing & commissioning of LT DG Set(s)

10

35357

-

... More
6" ANSI 600# Equal Tee

15

83172

-

... More
Dismantling steel work manually/ by mechanical means in built up sections without dismembering and stacking within 50 metres lead as per direction of Engineer-in-charge. [Notes: (1) Dismantling shall be allowed during day shift only & prior permission for the same shall be obtained. (2) Providing of necessary covers/ barricades around the work area shall be done prior to dismantling operations . (3) Cutting of steel shall be done using hack saw or chiesel or any other method as approved by the Engineer-in-Charge.]

200

724

-

... More
W.C. pan with ISI marked white solid plastic seat and lid

2

17606

-

... More
Supply of Cu- Cuso4 portable Half cell, as per specifications of approved make

2

12728

-

... More
Insulating Elastomer mats conforming to IS 15652:2006 of thickness 2 mm (Class A)

50

157900

-

... More
Cable Laying: Laying of all type of cables LT (PVC / XLPE / Armoured/Unarmoured/Power/ Control/ Signalling) in trenches, in cable racks, in trays, in protective pipes, poles, columns, in conduits, in panels and on structures etc.; including the supply and insta llation of all required materials such as fixing clamps, screws, cable straps, tags, etc. as required (other than the supply of the conduits, cables, pipes, cable racks, trays, poles, structures and panels) complete in all respect, including cost of all lab our, tools, consumable materials, etc. and cutting the cables in required lengths as per drawings, specification and directions of Site Engineer / Engineer-in-Charge:

-

-

-

... More
Supply and Erection of Electroforged Grating: Supplying at site, steel structural items such as steel plates, bars, fabrication of g ratings by electroforged method, after complete fabrication entire gratings shall be Hot Dip galvanized, gratings shall be normany of size 810mm X 250mm for steps and 1200mm X 1000 mm or 810mm X 1000 mm for platforms / walkways, or any size as advised by EIC. Pla cing gratings in a replaceable mannerbolting with base frame of ISA by suitable GI clamps and GI fasteners, including supply of all other inputs such as labour, materials, consumable etc. necessary to perform and complete the work in all respect, in accordance wit h drawings, specifications and instructions of the Site Engineer / EIC.

15

3488245

-

... More
Power cables LT : OD above 20 mm and upto 40 mm

50

2938

-

... More
Recess mounting type LED light fittings with LEDs: Supply & fixing of Recess mounted weather proof LED light fitting of PHILLIPS or equivalent approved make with LED of 42 W or more, having 2950 lumens or more output complete with all accessories such as LED modul e,driver,optics,thermal sink,connector blocks etc including installation with LED of approved make.

20

178855

-

... More
" Network Analysis: Model Building and Flow Analysis by using Pipenet/Sprink/Flowmaster Software, suggesting the requirement of orific e plate for flow and pressure control, preparation of reports, schematic drawings, recommendations and suggesting the pipe sizes in the fire water netwrok so that the fire fighting system meets the requirement of OISD 117, latest Edition. Completing the work in al l respect as per the defined scope of work and instructions of Site Engineer/EIC.Soft copy of Model in software to be provided in U SB drive to EIC/ Site Engineer"

2

640114

-

... More
Supplying and stacking sludge at site including royalty and carriage up to any lead complete. [Note: Volume of sludge measured in st acks will be reduced by 8% for payment].

6

2560

-

... More
GI wire (8 SWG)

3030

227645

-

... More
3 light points controlled by 1 switch

8

17910

-

... More
1:3:6 [1 cement : 3 coarse sand (Zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from n atural sources]

91

750043

-

... More
Providing and fixing 100mm wide Vertcal Fabric Blind system of VISTA/ MAC/ TRAC of approved make & shades complete along with standa rd accessories in required design/ shade as per manufacturer's recommendations, specification and directions of the Engineer-in-Char ge.

8

11618

-

... More
Soil Resitivity Survey

3

35854

-

... More
"Weight of unit above 1000 kg but upto and including 3000 kg "

3700

491786

-

... More
Conducting Mututal Interference Survey among the new and existing pipelines / facilities /foreign pipeline by taking PSP survey of a ll the pipelines as per approved procedure to determine level of interference at different places along the pipeline and at point of crossing in common ROW including identifying points and providing the data/ record in graphical form and carrying out all necess ary work for mitigating the interference observed among the pipelines , including retesting the same to ensure efficacy of the remed ial measures undertaken.The contractor shall submit a full final report with detailed PSP readings at all TLPs along with graphs in 3 sets.The item should be complete in all respect including survey, work for mitigating the interference and post mitigating survey as per specifications/directions of site engineer / Engineer-in-Charge.

-

-

-

... More
GENERAL WORKS :

-

-

-

... More
2 NPS (2.375" OD x 0.218"/ 0.344" WT) ASTM A106/ A333/ A53 Pipe

75

138502

-

... More
LED-Downlighter light fitting with LED: Supply and fixing of surface mounted weather proof light Downlighter LED of 15 W or more, ha ving 1000 lumens or more output of PHILLIPS or equivalent approved make complete with all accessories such as LED module, driver, op tics, thermal sink, connector blocks etc including installation.

28

272036

-

... More
Zinc Anode

163

1639423

-

... More
Water gel blanket

1

16332

-

... More
All works above plinth level upto floor V level

1

12907

-

... More
Cement concrete prepared with batch mixing machine

113

1302374

-

... More
FLP/ WP Emergency Shut Down Push Button Switch (with 2 nos. cable entry provision of 1/2" NPT) with steel hammer chained with main unit.

7

19701

-

... More
Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar lo cation in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of c ut edges etc. complete.

3

2901

-

... More
Polyester powder coated aluminium (Minimum thickness of polyester powder coating 50 micron)

411

251505

-

... More
Permanent half cell

9

88465

-

... More
Foundations, footings, bases of columns, etc. for mass concrete

661

247940

-

... More
Boring with hydraulic piling rigs with power units, providing and installing cast in situ single under reamed piles of specified dia meter and length below pile cap in M-25 cement concrete, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and the length of the pile to be embedded in pile cap etc. all complete. [Note: Length of pile for payment shall be measured upto to the bottom of pile cap] :

-

-

-

... More
6"x ANSI 600# F/F BS-1873 GLOBE Valve

2

174373

-

... More
Supplying, providing and filling fine sand in trenches in hard rocky stretches (Excluding additional 150mm deep trenching for rock trenching) around mainline pipe for providing a minimum padding thickness of 150 mm on top as well as at bottom of the mainline pipe. NOTE: (i) Item to be operated under specific instructions from Engineer-in-Charge (ii) Cost of additional depth of 150mm trenching for this item shall be paid separetly under item for "Extra for Rock trenching"

-

-

-

... More
Providing and fixing factory made precast RCC perforated drain covers, having concrete of strength not less than M-25, of size 1000x 450x50 mm, reinforced with 8 mm dia four nos longitudinal & 9 nos. cross sectional T.M.T. hoop bars, including providing 50 mm dia p erforations @ 100 to 125 mm c/c, including providing edge binding with M.S. flats of size 50 mm x 1.6 mm complete, all as per direct ions of the Engineer-in-Charge.

10

15944

-

... More
Beyond 120 cm girth upto and including 240 cm girth

45

465799

-

... More
50 mm X 6 mm G.I. earthing strip

1550

519198

-

... More
Lateral load testing of single pile in accordance with IS Code of practice IS:2911 (Part-IV) for determining safe allowable lateral load on pile :

-

-

-

... More
Providing and fixing in position 12 mm thick bitumen impregnated fiber board conforming to IS:1838, including cost of primer, sealin g compound Grade-A in expansion joints. [Note: Unit "CM" shall mean "PER CENTIMETRE DEPTH PER 100 METRE"]

1

734

-

... More
Nominal concrete 1:3:6 or richer mix (including equivalent design mix)

1

2287

-

... More
Providing and fixing in position pre-moulded joint filler in expansion joints. [Note: Unit "CM" shall mean "PER CENTIMETRE DEPTH PER CENTIMETRE WIDTH PER METRE LENGTH"].

1500

6106

-

... More
30 COMPOSITE

-

-

-

... More
6" BLRF 300#

2

5376

-

... More
3" NB - Double Cut Joint

3

15845

-

... More
Flexibility and piping stress analysis: Carrying out stress and flexibility analysis of process, utility and firewater piping includ ing creation of model in CAESAR-II (latest edition) software from isometric/ assembly piping drawings/ site measurements, analysis a s per relevant codes/ standards, interpretation, recommendations of suitable mitigation measures and design changes, if required as per specification and instructions of EIC/ Site Engineer. Soft copy of Model in software (CARSAR-II) to be provided in USB drive to EIC/ Site Engineer

2

444635

-

... More
6 mm cement plaster of mix 1:3 (1 cement : 3 fine sand)

414

123942

-

... More
Fasteners for Flanges 8" x 600# (1.125" Dia. X 8.25" Length)

24

10223

-

... More
6 mm cement plaster of mix 1:3 (1 cement : 3 fine sand)

9176

2747090

-

... More
415 V AC 3 phase / 230 V AC single phase motors: Connection and testing of 415 V AC 3 phase / 230 V AC single phase motors (includin g space heaters/thermistors wherever provided) / AC/DC Actuators including execution of terminal connection of control and power cab les, earthing of the motor/actuator/ connecting the thermistor, installing the controller in LT panel, earthing the motor frame, arm our etc. as per the drawings, erection manuals, and as per directions of Site Engineer. Job complete in all respects including the c ost of supplying and installation of all the required FLP/WP cable glands, reducers, adapeters, end lugs, GI earthing wire / strips, labour, tools, materials, etc., as required in all respects for all types of motors/heaters/thermistors/actuators etc.:

-

-

-

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :

-

-

-

... More
8" NB - Double Cut Joint

2

30420

-

... More
SANITARY INSTALLATIONS :

-

-

-

... More
Inside dimensions 500x700 mm and 45 cm deep for pipeline with one or two inlets :

5

45292

-

... More
Two or more coats on new work

1512

256134

-

... More
1:1.5:3 [1 cement : 1.5 coarse sand (Zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived fr om natural sources]

130

1321280

-

... More
Thermo-Mechanically Treated bars of grade Fe-500D or more

16997

1868860

-

... More
Construction of second class brick masonary open surface drain (Size: 200mm wide & 200mm average depth) in cement mortar 1:4 laid ov er a bed of 150mm thick cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) including mak ing haunches and providing 15mm thick cement plaster in CM 1:4 (1 cement : 4 coarse sand) with a floating coat of neat cement inside and its top and exposed surfaces, including excavatioin, disposal of the surplus earth up to any lead and lift as per standard desi gn and drawing, complete in all respects inclusive of cost of all labour, materials, carriages, excavation and refilling, curing etc ., as per specifications and directions of the Engineer-in-Charge.

96

230469

-

... More
Installation of Infrared HYDROCARBON DETECTORS (point type / open pathtype), terminating the cables at field and control panel / RTU end, connecting to earthing grid by supplying and installing all the required materials such as supporting structure, canopy, cemen t concrete, painting, GI wire etc.(excluding supply of the Hydrocarbon detector) complete in all respectsas per specifications.

15

85884

-

... More
8" x 4" ANSI 150# Un Equal Tee

5

34054

-

... More
Felling trees of the girth (measured at a height of 1 m above ground level), including cutting of trunks and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material :

-

-

-

... More
WATERPROOFING :

-

-

-

... More
Cement mortar 1:3 (1 cement : 3 coarse sand)

26

440281

-

... More
Providing and laying autoclaved aerated cement blocks masonry with 150 mm/ 230 mm/ 300 mm thick AAC blocks in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive m ortar all complete as per directions of Engineer-in-Charge. [Note: The payment of RCC band and reinforcement shall be made for seper ately].

69

603046

-

... More
Jet Nozzles

12

62785

-

... More
20 SERVICES

-

-

-

... More
4" SWMG ANSI 150#

40

8873

-

... More
Laying pre-coated pipes in Marshy areas with concrete sheathing including providing all equipment, works,labour, inputs and materials/consumable necessary to perform and complete the work in all respects, submission of construction procedure for Owner's approval, arranging the required additional land for construction purpose, preparation of site including dewatering, aligning, bending, lining up and welding the pipe, 100% radiographic inspection of weld joints, coating of field weld joints, holiday detection and repair of coating, hydrotesting testing and replacement of pipes/ defects, excavation of the trench to required depth in all kinds of soil and conditions including rock trenching and maintenance of trench in all kinds of soil including rocky strata, if any, and laying of the pipeline in approved trench, backfilling and final clean-up, stabilisation of the excavated banks, disposal of waste and surplus in accordance with the contract, and supply of materials (other than those specifically undertaken to be supplied by the Owner under the contract) necessary for or in the performance of the work or for temporary or permanent incorporation in the works and all other acts, matters and things necessary to complete the work in all respects according to the contract. NOTE: 1. Depending upon the site condition, the Engineer-in-Charge, in consultation with the Contractor, shall decide upon the precise operations necessary for the performance of the work to lay the pipeline across the canal/drain/rivers and the cost of all such operations necessary shall be deemed to have been included in the rate for this item. 2. Concrete sheathing work for marshy area laying shall be paid for separately under relevant item of Schedule of Rates. 3. Measurement for this item shall be as per pipe book covering laying in Marshy portion covering laying in Marshy portion covering entire concrete sheathing work only.

-

-

-

... More
Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in widt h as well as 10 sqm on plan) including getting out and disposal of excavated earth, all works up to any lead and lift, as directed b y the Engineer-in-Charge :

-

-

-

... More
Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per directions of the Engineer-in-Charge.

5

8734

-

... More
2" 300# Equal Tee-ASTM A420 Gr.WPL6

10

3563

-

... More
6.625" in Normal Soil

2780

28539480

-

... More
400 mm diameter piles

2

7772

-

... More
"INSULATING MATS: Supply & installation of 2000 mm X 1000 mm and of thickness as mentioned below, approved quality insulating Elastomer mats as per s pecifications."

-

-

-

... More
Angle Valve (Ref. Make: JAQUAR, Model: Cat. No. 0053 or approved equivalent)

10

19889

-

... More
600 mm dia R.C.C. pipes

37

145416

-

... More
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in :

-

-

-

... More
Dismantling steel work manually/ by mechanical means in built up sections without dismembering and stacking within 50 metres lead as per direction of Engineer-in-charge. [Notes: (1) Dismantling shall be allowed during day shift only & prior permission for the same shall be obtained. (2) Providing of necessary covers/ barricades around the work area shall be done prior to dismantling operations . (3) Cutting of steel shall be done using hack saw or chiesel or any other method as approved by the Engineer-in-Charge.]

100

362

-

... More
Providing and laying autoclaved aerated cement blocks masonry with 100 mm thick AAC blocks in super structure above plinth level up to floor V level in cement mortar 1:4 (1 cement : 4 coarse sand). The rate includes providing and placing in position 2 Nos 6 mm dia M.S. bars at every third course of masonry work.

73

790890

-

... More
Providing and fixing 15mm diameter C.P. brass angle valve as per following with C.P. copper connecting pipe 375mm long or as require d including nuts, washers, C.P. brass flange, etc. including cutting & making good the walls wherever required, etc. complete in all respects inclusive of cost of all materials, labour, tools, tackles etc. as per specifications and directions of the Engineer-in-Ch arge :

-

-

-

... More
Supplying and filling selected earth/ moorum (excluding black cotton soil) from Contractor's own borrow areas including royalty, wit h all leads and lifts in low laying areas and filling to required grade and level including watering, compacting at optimum moisture content to 90% of Proctor's density, consolidation and rolling with 8 to 10 tonne power roller in layers not exceeding 20 cm thic kness, complete in all respects inclusive of cost of all labour, materials, tools, tackles etc. as per drawings, specifications and directions of the Engineer-in-Charge.

2351

1278314

-

... More
80 x 1.25 mm M.S. laths with 1.25 mm thick top cover

8

31015

-

... More
EARTHWORK :

-

-

-

... More
Providing and fixing square mouth S.W. gully trap class SP-1 complete with C.I. grating, brick masonry chamber with water tight C.I. cover with frame of 300x300 mm size (inside dimension). The brick masonary chamber shall be constructed with common burnt clay F.P. S. (Non-modular) bricks of class designation 7.5. [Note: Weight of the cover shall not less than 4.50 kg and weight of the frame sha ll not be less than 2.70 kg as per standard design] :

-

-

-

... More
100 mm diameter :

-

-

-

... More
Execution of road/other crossing by Shallow Horizontal Directional Drilling (HDD) technique including mobilization & de-mobilization at site(s), supply of all materials as per the `Scope of Supply' and all consumables, equipment, manpower & other resources and arranging the required land for site preparations and execution of, but not limited to, the following works in accordance with the specifications, drawings and as per all provisions of the contract document complete in all respect as per the instructions of the Engineer – in – charge /Site engineer. Taking delivery and transportation of Owner-supplied 3LPE coated pipes to the work site from designated stockpile location, inspection of the coated pipes visually and/or with holiday detector for defects, including arranging all necessary intermediate storage area required thereof till the pipes are installed in permanent position. Complete site preparation including arranging of required land, setting up of fabrication yard, preparation of temporary arrangement for pipeline stringing, launching etc Carrying out repair of pipe defects, replacement in the case of non-repairable defects and repairing damages to pipe coating including defects/ damages occurring during transportation and handling. String preparation including repair of pipe and pipe coating defects, welding, non-destructive testing of welds including 100% radiography (by X-ray), supply of films & all equipment and providing all facilities to Owner's representative(s) for examining radiographs, repair of defects in the welds and re-testing etc. Carrying out pre-installation hydrostatic testing of the complete pipeline string, as per the specifications, including repair of defects and retesting etc. Coating of the field joints of the pipe string to be installed by shallow HDD method with DIRAX heat shrink sleeves of M/s Raychem's make, DDXTM Directional Drilling Kit of M/s Canusa or of any other approved make used for HDD crossings. Repair of all coating damages in the pipe section to be laid by shallow HDD method by full encirclement sleeves using suitable cut sections of approved quality of heat shrink sleeves of M/s Raychem make, DDXTM Directional Drilling Kit of M/s Canusa or of any other approved make. Repair of all coating damages in the pipe section to be laid by shallow HDD method by full encirclement sleeves using suitable cut sections of approved quality of heat shrink sleeves of M/s Raychem make, DDXTM Directional Drilling Kit of M/s Canusa or of any other approved make. Fabrication of 89mm OD steel conduit with an inner duct of 40mm OD HDPE pipe for OFC (wherever OFC has to be laid along with the carrier pipeline). Supply & fixing of easy to install heat shrinkable duct end caps for HDPE conduit for OFC (wherever OFC has to be laid along with the carrier pipeline) Installation of the pipeline and OFC conduit as a bundle crossing below the Road/ other utility horizontally by shallow HDD operation to the correct profile as per the approved drawings in a pre-reamed hole of appropriate. Carrying out post-installation coating survey as per approved procedure. Restoration, clean-up and disposal of drilling fluid, waste and all other surplus materials etc. All other works not specifically listed herein, but required as per specifications, drawings, provisions of the contract document, calculations and construction method statement, leading to successful completion of the works. Note :- The item to be operated under the specific instruction of Engineer in Charge

-

-

-

... More
RAINWATER HARVESTING & TUBEWELLS :

-

-

-

... More
2"x1" 300# Unequal Tee-ASTM A420 Gr.WPL6

2

2057

-

... More
Composite- CP System Electrical

-

-

-

... More
Providing and fixing toilet paper holder :

-

-

-

... More
Grading roof for water proofing treatment with :

-

-

-

... More
6" 300# Equal Tee-ASTM A420 Gr.WPL6

10

20921

-

... More
Supply, installation, testing of earthing system consisting of 3 earth pits of perforated GI pipes earthing electrodes and copper plate terminal block including construction of chamber using cement concrete with earthing pit cover and frame, supply of charcoal, salt etc including supply of interconnecting cables / strips including necessary welding etc complete as per drawings, specifications and directions of the site engineer, including cost of tools, materials etc complete in all respects as per drawing The job shall also include testing of each earth pit and the entire earthing system on whole. (Note: Earthing for field instruments shall be provided from Station earth grid covered in Electrical SOR.)

14

1055526

-

... More
6.625" in Normal Soil

10

129800

-

... More
Brick work with common burnt clay F.P.S. (non-modular) bricks of class designation 7.5 in superstructure above plinth level up to fl oor V level in all shapes and sizes in :

-

-

-

... More
With cement concrete 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 10 mm nominal size).

9

188095

-

... More
Installation of Permanent half cells including connecting the cable in the TLP etc. with cable lugs, sealing material, laying of cab le, testing & commissioning of cell etc. all complete with required material, excavation, backfilling etc. as per specifications, r ecommendation of cell supplier and directions of Site Engineer / Engineer-in-Charge.

-

-

-

... More
5/4" Plugs

30

2704

-

... More
Providing and fixing 75mm diameter P.V.C. pipe (4 Kg/sq.cm) for Weep Holes in Masonry/ RCC wall including providing 230x230x230 mm s ize (approx.) filter using pebles of 40mm & down size in every weep hole on retaining side etc. complete in all respects inclusive o f cost of all materials, labour, tools, tackles etc. as per specifications and directions of the Engineer-in-Charge.

33

11993

-

... More
In dado/ skirting on 12 mm thick mortar 1:4 (1 acid and/or alkali resistant cement : 4 coarse sand) :

115

243463

-

... More
Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7 Kg per square metre on dam p proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil.

68

9849

-

... More
FINISHING :

-

-

-

... More
Extra for pre finished nosing in treads of steps of Kota Stone slab.

48

9360

-

... More
Sand drum with scoop

4

11634

-

... More
Insulating Elastomer mats conforming to IS 15652:2006 of thickness 2.5 mm (Class B)

47

147811

-

... More
Providing and laying Non Pressure NP-3 class (Medium duty) R.C.C. pipes including collars/ spigot jointed with stiff mixture of ceme nt mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete :

-

-

-

... More
"Final Commisioning of CP system Final Commissioning of the impressed current cathodic protection system for the mainline for achieving full protection as per protec tion criteria as mentioned in the specifictions through repeated adjustments of the CP units after installation of galvanic anodes f or hot spot protection and mitigation of AC/ DC interference, if any and submission of the resultant data to the owner and testing, measuring, recording and submitting all these data once again after the lapse of a period as per specifications / directions of the Site engineer / Engineer-in-Charge, including the cost of all labour tools and materials as required, complete in all respect."

-

-

-

... More
2" BLRF 300#

5

2784

-

... More
25 mm nominal bore

3

1963

-

... More
Thermo-Mechanically Treated bars of grade Fe-500D or more

167652

18433739

-

... More
Cement mortar 1:4 (1 cement : 4 coarse sand)

180

183401

-

... More
3", 300#/900#, F/F

4

23741

-

... More
Supply of flame proof and weather proof fittings including EP/WP certificates as per the technical specifications attached.

-

-

-

... More
HORTICULTURE & LANDSCAPING :

-

-

-

... More
Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.

37

95158

-

... More
Thermo-Mechanically Treated bars of grade Fe-500D or more

12441

1367917

-

... More
REINFORCED CEMENT CONCRETE :

-

-

-

... More
Laying of HDPE pipe(excluding blowing of OFC) in mainline pipe trench/ independent trench at the bottom in all types of soil (including roads, canals, rivers, nullahs, water course crossings, submerged crossings, saltpan areas etc.) including supply and installation of suitable straps for strapping the HDPE duct with mainline pipe for anti buoyancy, installation of HDPE duct accessories such as plastic couplers, end caps, end plugs, cable sealing plugs, supply and installation of warning tape, consumable guide rods, HDPE jointing, inspection of HDPE joints, testing the installed HDPE duct by blowing "mandrel" with compressed air, pressure testing the HDPE pipe after laying as per procedure and performing all work as per drawings, specifications and instruction of the Engineer-in-charge/ Site Engineer and provisions of the contract document for making the duct ready in all respect for OFC blowing. The job includes transportation, loading and unloading of HDPE ducts in nominal length of 1000 meters and duct accessories such as couplers, end caps, end sealing plugs etc. to various sites along the entire ROW / HDD crossing locations as per specifications and directions of Engineer-in-charge/ Site Engineer

101

2270500

-

... More
INSTALLATION OF TEMPERATURE TRANSMITTER WITH THERMOWELL: Installation and assistance in testing & commissioning of temperature eleme nts/temperature transmitter(TT) by making necessary holes on the pipes, welding the socket for thermowell on the pipe including sup ply of boss, silicon paste etc as per the directions of engineer in-charge/site engineer and drawings.

2

20205

-

... More
10.75" ODx 0.250" WT IS3589 Pipe

350

1647457

-

... More
Fasteners for Flanges 3" x 600# ( 0.75" Dia. X 6.75" Length ) - extended stud length for flanges with spectacle blind

24

3794

-

... More
6" NB - Double Cut Joint

2

24152

-

... More
4"x ANSI 600# HOV F/F API 6D Ball

2

104876

-

... More
Boring, providing and installation bored cast-in-situ reinforced cement concrete piles of grade M-25 of specified diameter and lengt h below the pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the le ngth of the pile to be embedded in the pile cap etc. by percussion drilling using Direct mud circulation (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, including removal of excavated earth with all its lifts and leads [No tes: (1) Length of pile for payment shall be measured up to bottom of pile cap. (2) Truck Mounted rotary/ TMR/ Tubewell boring machi ne shall not be used] :

-

-

-

... More
450 mm diameter piles

10

23784

-

... More
6" 600# Equal Cross bar Tee

3

19961

-

... More
Supply of Pipe locator cum Current Mapper with GPS and with A frame and all accessories of approved make as per specifications comp lete in all respects

1

334314

-

... More
101 - 300 METERS (with OFC conduit)

-

-

-

... More
Extra for providing and placing in position 2 Nos. 6 mm dia. M.S. bars at every third course of half brick masonry.

73

7699

-

... More
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concr ete work, using coarse aggregate as well as fine aggregate derived from natural sources and cement content as per approved design mi x, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, inc luding admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per directions of the Engineer-in-Charge. [Note : Cement content considered in this item is @ 3 30 kg/cum. Excess/ less cement used as per design mix is payable/ recoverable separately.] :

-

-

-

... More
4 NPS 4.5" OD x 0.237"/0.337" WT ASTM A106/ A333/ A53 Pipe

270

922028

-

... More
Neat cement punning.

422

34867

-

... More
Supply of fire buckets mounted on stand

18

67330

-

... More
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete :

-

-

-

... More
25mm x 4 mm copper flat

50

45473

-

... More
4" SWMG ANSI 600#

150

71331

-

... More
Single pile up to 50 tonne Safe Capacity :

-

-

-

... More
Up to 5 mm depth and 5 mm width

353

58148

-

... More
4.500" ODx 0.237" WT (Sch.STD) ASTM A 106 Gr B Bare Pipe

50

172457

-

... More
"Weight of unit above 3000 kg but upto and including 6000 kg "

4500

647766

-

... More
1:3:6 [1 cement : 3 coarse sand (Zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from n atural sources]

72

593441

-

... More
Constructing brick masonry Septic Tank with brickwork in cement mortar 1:6 including R.C.C. 1:2:4 (1 cement : 2 sand : 4 graded coar se aggregate) top slab, C.I. cover all as per standard drawing, etc. complete in all respects inclusive of cost of all materials, la bour, tools, tackles etc. as per drawings, specifications and directions of the Engineer-in-Charge :

-

-

-

... More
Supply of Cu- Cuso4 Permanent Half cell with minimum 10 m length of tail cable, as per specifications of approved make

9

93700

-

... More
4" x 150# 90° LR Bends

20

20886

-

... More
230 V AC operated auto type Cathodic Protection Transformer Rectifier (CPTR) unit of rating 25 V 25 A DC with SCADA linking facility

1

42067

-

... More
Retrievable flush ER probe

1

70564

-

... More
"Conducting AC interference survey, to detect presence of any AC voltage(induced owing to proximity of any HT transmission line (33 KV and above) crossing or running parallel within a distance of 60 M from the pipeline alignment as per approved procedure. The wor k shall be completed in all respects including survey, data logging for specified period, recommending mitigation measures & post mi tigation survey. The work includes all tools, tackles, consumables etc. all complete, required for survey / test as deemed necessary and as per the directions of the site engineer / Engineer-in-Charge. Note : AC interference survey shall be done at respective TLP by connecting data logger to maintain record for minimum 24 hours. The data to be submitted for each such TLP alongwith coloured graph and recommendations."

-

-

-

... More
Supplying, providing and filling soft soil in trenches in stretches other than normal soil and hard rock (including additional 150mm deep trenching) around mainline pipe for providing a minimum padding thickness of 150mm on top as well as at bottom of the mainline pipe. Padding materials shall be sand/graded soil/other suitable material containing no gravel, rock, or lumps of hard soil. The graded soil for padding shall pass through sieve size ASTM-10 or ISO-2.00. Acceptable padding shall be placed under the pipeline before its installation and around it after installation, to establish at both sides and on top of the pipe a permanent layer of padding. The thickness of compacted padding shall be at least 150mm. The trench shall be deeper by at least 150mm. The trench shall be evenly and sufficiently padded to keep the pipe, when in place, at least 150mm above the bottom of excavated trench. NOTE: (i) Item to be operated under specific instructions from Engineer-in-Charge (ii) Cost of additional depth of 150mm trenching for this item shall be included in this item itself.

-

-

-

... More
PILE WORK :

-

-

-

... More
Flameproof & weatherproof Anode Junction Box of approved make

3

51956

-

... More
Close Interval ON/OFF Potential logging survey

85

423313

-

... More
4.5" ODx 0.237" WT ASTM A106/ ASTM A53/ API 5LGr B Pipe

50

99887

-

... More
With stainless steel cover plate minimum 1.25 mm thickness

20

63537

-

... More
3"x2" 300# Unequal Tee-ASTM A420 Gr.WPL6

8

12356

-

... More
Supplying, fitting and fixing hot dip galvinised barbed line wire through holes in fencing posts (already made in the body of the po st), tightening and fixing the wire in tight condition with straining bolts (straining bolts at end post) including the cost of cutt ing and lapping joints, making holes, straining bolts, galvanised staples, binding wires etc. complete in all respects inclusive of cost of all labour, materials, tools, tackles etc. as per drawings, specifications and directions of the Engineer-in-Charge.

4000

2708760

-

... More
3 NPS (3.5" OD x 0.216"/ 0.438" WT) ASTM A106/ A333/ A53 Pipe

220

486230

-

... More
Supplying all labour, materials, tools, chemicals, spray pumps etc. for making pre-constructional anti-termite treatment & creating a continuous chemical barrier under & all round the column pits, wall trenches, top surface of plinth filling, junction of wall & fl oor, along the exterior perimeter of the building, complete in all respects inclusive of cost of all labour, materials, tools, tackl es etc. as per drawings, specifications and direction of Site Engineer. [Note: Total plinth area of the building shall be measured for payment].

632

208924

-

... More
Critical Light DB: Euro DB DBOXx of Havells or equivalent make complete with bus bar, neutral links, earth links and 1 x 6 A MCB SPN & 7x2 A SPN MCB.

1

11587

-

... More
Inside dimensions 500x700 mm and 45 cm deep for pipeline with one or two inlets :

1

9058

-

... More
12" Sweep

7

48957

-

... More
Type B (With Ingress Protection IP:55)

43

1920460

-

... More
Explosimeter

1

46422

-

... More
10" NB - Double Cut Joint

2

38803

-

... More
Swan neck lighting pole with LED well glass light: Supply, installation, testing and commissioning of swan neck lighting pole of 10 0mm nominal Diameter B class MS pipe (Height of bottom of light fitting shall be 5 meters from FGL), having base Plate 200mmx200mmx5 mm along with Flameproof and Weatherproof 2x18W LED well glass light fitting complete with lamp and builtin control gear and choke of approved make, including supply and installation of earthing conductor of 8 SWG GI wire, nuts, bolts, Neck portion of lighting po le shall made up be of 50mm diameter GI pipe (radius of neck shall be 250mm). The pole shall be painted with 01 coat of primer and 0 2 coats of aluminium paint. The job shall also include supply and installation of 4 way Flameproof/weather proof junction box (with 4 cable entries) having 8 Nos., 6A, 440V shrouded terminal, with double compression FLP glands/lugs with looping arrangement and sup ply and termination of 3C X 2.5 sq. mm. armoured copper PVC/XLPE insulated cable from JB to light fitting The job complete in all re spects as per specifications, drawings and instructions of EIC / Site engineer.

11

337084

-

... More
Bib Cock (Ref. Make: JAQUAR, Model: Cat. No. 0037 or approved equivelent)

3

6039

-

... More
PA system/ Loudhailer/ megaphone

1

31544

-

... More
"FLAME PROOF FITTINGS: All equipment under this category shall be suitable (minimum requirments) for location in zone-I gas group IIA & IIB (Temp. class T3 ) area with a separate terminal box for incoming cable and a separate terminal box for out going cable (where applicable), apart fro m separate enclosure for each equipment including control gear etc. in IP 65 cast aluminium LM-6 certified enclosure: "

-

-

-

... More
8.625" ODx 0.250" WT IS3589 Pipe

10

38232

-

... More
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto pli nth level :

-

-

-

... More
Thermo-Mechanically Treated bars of grade Fe-500D or more

30520

3355747

-

... More
Constructing brick masonry chamber for underground C.I. inspection chamber and bends with common burnt clay F.P.S. (Non-modular) bri cks of class designation 7.5 in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 Kg and weight of frame 15 Kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cemen t : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design :

-

-

-

... More
Centering and shuttering including strutting, propping etc. and removal of formwork for :

-

-

-

... More
Beyond 120 cm girth upto and including 240 cm girth

18

186319

-

... More
Cement mortar 1:3 (1 cement :3 coarse sand)

73

91957

-

... More
Above ground process piping: Taking delivery & transporting of pipes from designated stock pile location /Designated godown both fro m outside & inside station premises. Taking delivery of pipe fittings, steel flanges, spiral wound metallic gaskets & fasteners from designated location within station premises, transporting the same to site, fabrication and erection of above ground piping includi ng cutting, edge preparation, bending, threading, lining up, welding and installing pipes and pipe fittings, flanges, elbows, equal and reducing outlet tees,concentric/eccentric reducers, y-type strainers, drain funnels, vent pipes and tapping for instruments such as pressure gauges, thermal relief valves, thermowells etc., installing above ground at all elevations connecting with equipment no zzles, valves, vessels, in line instruments etc., welded and threaded pipe line of different pressure ratings, flushing pipes by wat er after cleaning by compressed air, hydrostatic testing of each section to the specified pressure, draining the water, tie-in, fina l cleaning-up and dispoal of wastes and surpluses including providing all inputs such as labour, material, equipments and consumable s necessary to perform the work (other than those specifically under taken by the owner in this contract) and completing the work in all respects in accordance with the drawings, specifications and instructions of Site Engineer / EIC. Thickness and Grade mentioned in the item are for reference only and may vary. Payment shall be based on OD

-

-

-

... More
Disposal of building rubbish/ malba/ similar unserviceable, dismantled or waste materials by mechanical means, including loading, tr ansporting, unloading to approved municipal dumping ground or as approved by the Engineer-in-Charge, beyond 50 m initial lead, for a ll leads including all lifts involved.

10

1828

-

... More
DC distribution board with one incomer, 100 A DP MCB & outgoing feeders 1x63A DP MCB & 2x32 A DP MCB

2

52860

-

... More
Mainline CP & Station CP : Anode bed deep well type

2

1373978

-

... More
Cat 6 UTP (LAN) Networking Cable as per tender specifications

750

21275

-

... More
"Above Ground Equipments Installation: Single Basket Type Strainers along with all accessories, JIB Crane, etc as applicable. Taking delivery of equipments, shifting/transporting within station premises, placing on pre-constructed foundations, assembling together all sub-assemblies, levelling, alignment, grouting, cleaning and flushing by water, draining, checking, testing, dressing and making good of the foundation and completing the work in all respects in accordance with the relevant drawings, manufacturer's installati on instruction, specifications and instructions of Site Engineer / EIC., Note: Weight of equipment is indicative only, Payment shall be done based on actual weight of equipment"

2

93505

-

... More
Supplying, providing and filling fine sand in trenches at Seismic Fault location crossing or running parallel to pipeline (including additional 500 mm deep & 200/300 mm wide trenching) around mainline pipe for providing a minimum padding thickness of 500 mm on top as well as at bottom of the mainline pipe(for the complete trench width). Note: (i) Item to be operated under specific instructions from Engineer-in-Charge. (ii) Cost of additional depth of 500mm & width of 200/300 mm trenching for this item shall be included in this item itself.

-

-

-

... More
In Ordinary rock

144

66832

-

... More
3" WNRF 300#

10

12354

-

... More
Angle Valve (Ref. Make: JAQUAR, Model: Cat. No. 0053 or approved equivalent)

3

5966

-

... More
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto pli nth level :

-

-

-

... More
Multi Sensor Detectors & isolators Installation, testing & commissioning of Multi sensor detectors, laying of signalling cables (through conduit/ clamping on wall etc), clamping / fixing of GI conduit in various building, pump shed etc for integration of detectors with RTU including all mounting accessories for support, termination of cables etc. as per the approved scheme to complete the work in all respects inclusive of supply of all consumables ,cost of all materials, labour, painting services, carriages etc. as per specifications, drawings, International Standard practices and the directions of Site Engineer/EIC. Job includes installation of all types of detectors, material etc

24

32827

-

... More
Supply - CP System Electrical

-

-

-

... More
Providing & fixing 6mm thick, copper back finish, looking mirror of required size, made of float sheet glass of best quality & appro ved make, over 12mm thick marine board fixed to rawl plug with round head screws & washers including teakwood beading with melamine polish all around, complete in all respects inclusive of cost of all materials, labour, tools, tackles etc. as per specifications an d directions of the Engineer-in-Charge.

2

6922

-

... More
Providing and laying damp-proof course 50 mm thick with cement concrete 1:2:4 [1 cement : 2 coarse sand (Zone-III) derived from natu ral sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources]

68

37509

-

... More
60mm thick Cement Concrete paver block of M-35 grade with approved colour, design & pattern.

1400

1631085

-

... More
Size of Tile 500x500 mm

60

100168

-

... More
2" 600# 90 deg LR Bend

30

18337

-

... More
4", 600#/900#, W/W

15

142449

-

... More
Designing, fabricating, testing, installing and fixing in position Curtain Wall with Aluminium Composite Panel Cladding, with open g rooves for linear as well as curvilinear portions of the building, for all heights and all levels etc. including: (A) Structural ana lysis & design and preparation of shop drawings for pressure equalisation or rain screen principle as required, proper drainage of w ater to make it watertight including checking of all the structural and functional design. (B) Providing, fabricating, supplying and fixing panels of aluminium composite panel cladding in pan shape in metalic colour of approved shades made out of 4 mm thick alumin ium composite panel material consisting of 3 mm thick FR grade mineral core sandwiched between two Aluminium sheets (each 0.5 mm thi ck). The aluminium composite panel cladding sheet shall be coil coated, with Kynar 500 based PVDF/ Lumiflon based fluoropolymer resi n coating of approved colour and shade on face #1 and polymer (Service) coating on face #2 as specified using stainless steel screws , nuts, bolts, washers, cleats, weather silicone sealant, backer rods etc. (C) The fastening brackets of Aluminium alloy 6005 T5/ MS with Hot Dip Galvanised with serrations and serrated washers to arrest the wind load movement, fasteners, SS 316 Pins and anchor bo lts of approved make in SS 316, Nylon separators to prevent bi-metallic contacts all complete required to perform as per specificati on and drawing. The item includes cost of all material & labour component, the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working curtain wall with aluminium co mposite panel cladding, cleaning and protection of the curtain wall with aluminium composite panel cladding till the handing over of the building for occupation. Base frame work for ACP cladding is payable under the relevant aluminium items. The Contractor shall p rovide curtain wall with aluminium composite panel cladding, having all the performance characteristics all complete, as per the Arc hitectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer-in-Cha rge. However, for the purpose of payment, only the actual area on the external face of the curtain wall with Aluminum Composite Pane l Cladding (including width of groove) shall be measured in square metre up to two decimal places.

10

56753

-

... More
6" 600# 90 deg LR Bend

40

205839

-

... More
2" Spectacle Blind 600# F/F

12

101852

-

... More
3" BLRF 300#

5

5492

-

... More
3" NB Piping

2

8208

-

... More
6.625" in Rocky Soil

10

187620

-

... More
1:4:8 [1 cement : 4 coarse sand (Zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from n atural sources]

10

76239

-

... More
80 mm nominal dia pipes

194

502209

-

... More
Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete :

-

-

-

... More
Providing and fixing the following washroom fittings, complete in all respects; inclusive of cost of all materials, labour, tools, t ackles etc. as per specifications and directions of the Engineer-in-Charge :

-

-

-

... More
Supply of hand held data logger for ON/OFF PSP measurement alongwith carrying case, data downloading cable and other required access ories complete as per specifications and approved make

1

162350

-

... More
Supply of Solid State Diode Decoupling Device (min 5 kA @ 30 cycles) of approved make including required length of cable as per spec ifications

-

-

-

... More
PU /liquid epoxy Coating of under ground piping: Cleaning exposed steel surfaces of piping, equipment and valves etc. by abrasive bl asting or with power wire brush (wherever sand blast cleaning is not possible) free of dust, grease, mill scales etc. and applying single layer polyurethane coating(PU) using 100% solvent free elastomeric plyurethane/ liquid epoxy, with approved materials, labour , equipment etc. and completing the job in all respects as per specification and instructions of the Site Engineer / EIC.

400

1164896

-

... More
Providing and fixing special coloured glazed vitreous China clay pedestal type aesthetic Wash Basin of 580x500 mm size (Ref. Make: H INDWARE, Model: Cat No.-10050 or equivalent approved) with M.S. or C.I. brackets painted white, C.P. brass chain with rubber plug, 3 2mm C.P. brass waste coupling of standard pattern, 32mm C.P. brass bottle trap and union, 32mm dia C.P. pipes to wall flange etc., i ncluding cutting and making good the walls & floors wherever required, etc. complete in all respects inclusive of cost of all requir ed fittings, fixtures, materials, labour, tools, tackles etc. as per specifications and directions of the Engineer-in-Charge.

1

11552

-

... More
"Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cist ern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS:2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required : "

-

-

-

... More
FLAMEPROOF LED WELL GLASS FITTING 125 W: Supply, installation, testing & commissioning of Ex'd' (Flameproof) Well Glass Light Fixtur e with provision of Cable Entries: 2 Nos. x 3/4" ET, Cable Glands: 2 Nos. x 3/4" ET (Max. OD 20mm) - Ex'd'(IIA/IIB), Double Compres sion type, Brass Nickel Plated with PVC Hood. Blanking Plug: 1 No. x 3/4" ET - Ex'd', Brass Nickel Plated. Gasket: Neoprene, Hardwar e: SS 304, Earthing: External 2 Nos. (M6), Internal 1 No. (M5), and as per attached detailed technical specification.

34

1154527

-

... More
Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS:6315, having brand logo embossed on the body/ plate with double spring mechanism and door weight up to 125 Kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per directions of the Engineer-in-Charge. :

-

-

-

... More
Holes 1.2 m diameter and 1.2 m deep

10

4705

-

... More
1.315" ODx 0.179"WT (Sch.XS) ASTM A 106 Gr B Bare pipe

50

38055

-

... More
6"x4" 600# Unequal Tee Cross Bar

12

99199

-

... More
LT Cable joint (1.1 KV): Making straight through joints on Al/Cu conductor XLPE/PVC insulated armoured cable including the supply of required materials such as cable jointing kit (of heat shrinkable sleeve type of Raychem/Mseal/3M) , materials, labour, tools and t ackles, consumables etc , as per drawings, specification and directions of Site Engineer / Engineer-in-Charge:

-

-

-

... More
Centering and shuttering including strutting, propping etc. and removal of formwork for :

-

-

-

... More
Type C (With Ingress Protection IP:55)

4

109787

-

... More
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete :

-

-

-

... More
CO2 cartridge - 200 gm capacity for 9 kg

10

7764

-

... More
Radium sticker lettering: Reflective radium sticker letter printing and apply in background stickering including pasting and fixing with supply of all manpower, equipments, tools, tackles, consumables, non-consumables, scaffolding (separate SOR item) working at an y height etc. as per instruction of EIC/ Site Engineer to complete work in all respects.

110

212352

-

... More
Supply of 89 mm OD, Schedule 80, API 5L Grade-B/ ASTM A106 MS pipe for cable conduit as per tender specifications

6948

13289257

-

... More
1" x 800# Ball valve HOV W/W BS 5351/ ISO 17292

110

1650796

-

... More
Foundations, footings, bases for columns

886

332337

-

... More
10"x ANSI 150# HOV F/F API 600 Gate Valve

15

830413

-

... More
10" NB - Mitre Bend (angle more than 45° & up to 90°)

1

23473

-

... More
Centering and shuttering including strutting, propping etc. and removal of form for all heights :

-

-

-

... More
Temporary Barricading: Providing Temporary Barricading made of GI/ steel sheet with angle iron frame (40x40x6) in panels of 1.5 to 2 .0m including lateral/ vertical angle bracing/ steel beam at bottom for stability, earth filling up to 300mm height above ground lev el, maintaining the barricading during construction at site, removing the same and clearing site after construction complete in all respects as per instructions of Site Engineer

500

1326320

-

... More
Ceiling fan wiring: Wiring with PVC insulated 2.5 sqmm copper conductor wire for fan points (1 fan point controlled by 1 modular swi tch) including providing space for electronic regulator in switch box, providing and fixing fan hook in the ceiling as per specifica tions and drawings.

19

44909

-

... More
4" ANSI 600# Equal Tee

14

27158

-

... More
"Weight of unit above 100 kg but upto and including 500 kg "

100

8086

-

... More
2", 150#/300#, F/F

8

28773

-

... More
6.625"

86

918394

-

... More
4"x3" 300# Unequal Tee-ASTM A420 Gr.WPL6

2

4113

-

... More
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above pl inth level :

-

-

-

... More
Providing and laying Dense Graded Bituminous Macadam using crushed stone aggregates of specified grading, premixed with bituminous b inder and filler, transporting the hot mix to work site by tippers, laying with paver finisher equiped with electronic sensor to the required grade, level and alignment and rolling with smooth wheeled, vibratory and tandem rollers as per specifications to achieve the desired compaction and density, complete as per specificatons and directions of the Engineer-in-Charge :

-

-

-

... More
"Under ground piping for Fire Water Piping (with external PU/3LPE Coating and internal epoxy coating at welding joints, fittings and flanges) Taking delivery of internal coated Pipes, pipe fittings, steel flanges, spiral wound metallic gaskets & fasteners from des ignated location within station premises, transporting the same to site, fabrication and erection of underground piping including cu tting, edge preparation, bending, threading, lining up and welding, excavating, trenching in all kind of soil to specific depths as indicated in drawings and installing pipes and all types of pipe fittings like flanges, elbows, equal and reducing outlet tees, conc entric/ eccentric reducers, drain funnels, vent pipe and tapping for instrument such as pessure gauges, thermal relief valves, therm owells etc., underground at elevations indicated in the drawing connecting with equipment nozzles, valves, vessels, in-line instrume nts etc.,Cleaning exposed steel surfaces of Bare Pipes, Pipe Joints, Fittings, Flanges,equipment and valves etc. by sand blasting or with power wire brush (wherever sand blast cleaning is not possible) free of dust, grease, mill scales etc. and applying 100% solve nt free elastomeric plyurethane (PU)/ liquid epoxy on external surface, with approved materials, Equipment etc, holiday detection of the coating, cleaning of internal surface of pipes conforming to SSPC SP-10 at all location where internal coating has been distroy ed due to welding and repairing the internal surface by application of 2-pack cold cured Isophthalic polyster acrylic co-polymer gla ss flake filled /Liquid epoxy / Equivalent with coating of thickness 700-1000 Microns. Internal coating shall also be done at the in ner surface of pipe ends, Flanges, pipe fittings, valves, etc so that the internal surface of piping is not directly exposed to wate r; cleaning of coated pipes by water flushing after cleaning by compresed air,hydrostatic testing of each section to the specified p ressure, draining the water, tie-in, back filling, restoration of site final cleaning up and disposal of water and surpluses, provid ing all inputs such as labour, materials equipment and consumable necessary to perform the work (other than those specifically under taken to be supplied by the owner under the contract) and completing the work in all respects in accordance with the drawings, spec ifications and instructions of the Site Engineer / EIC. Note: 1. In case of 3LPE coated pipes, weld joints shall be PU coated.Thickness and Grade mentioned in the item are for reference only and may vary. Payment shall be based on OD. 2. Payment for external PU/ epoxy coating shall be done separately as per relevant SOR item."

-

-

-

... More
AIR CONDITIONER CASSETTE TYPE - Supply & Installation of 1.8T Cassette Type ACs flushed with false ceiling (Daiken / Hitachi / Car rier) along with 5KVA Voltage Stablizer & MS stand for outdoor unit, refregerant piping, drain piping complete as per instruction of EIC / Site Engineer

8

1580176

-

... More
Polyester powder coated (Minimum thickness 50 micron) aluminium tubular handle bar

20

15162

-

... More
8", 150#/300#, F/F

3

43163

-

... More
2", 600#/900#, F/F

60

237392

-

... More
"Supply & installation of MMO type anodes as per the approved configuration for 'Impressed Current Cathodic Protection' system of s tation piping / structures including all anodes, laying & termination of all anode tail cable (XLPE insulated copper conductor) suit able with length for connecting upto Anode junction box without any joints in between including supply and laying of PVC sleeve / t runk pipe & drawing all the lead wires through the pipe and connecting the same with Anode bus in Anode junction box including erec tion, providing foundations of Anode Junction Boxes & Cathode Junction Boxes, providing chain link fencing around Anode junction Box wherever required, as per specifications including supply of back fill material, excavation, backfill of earth and filling the san d with requisite back fill material as per specification & also compacting the same with soil for restoring it to normal finished gr ound level all complete with all labour and material as per instruction of Site Engineer / Engineer-in-Charge, Specifications and a pproved drawings. Note : Supply of anode tail cable for distributed anodes for station CP are covered elsewhere in SOR"

-

-

-

... More
Supply of Pressure Indicators (PI) of the following ranges as per the technical specifications attached in the Tender. Range: 0 - 100 kg/cm2

10

58099

-

... More
Type III Distribution Board: Double Door EURODB of Havells or equivalent approved make having bus bar 200 A TPN, 1 Incomer 125 A FP MCB Isolator with 125 A FP RCCB (Senstivity 100 mA) alongwith 3 numbers 63 A TPN MCB as per specification.

6

641167

-

... More
Fasteners for Flanges 6" x 600# (1.000" Dia. X 7.50" Length)

720

202204

-

... More
Centering and shuttering including strutting, propping etc. and removal of formwork for :

-

-

-

... More
Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in widt h as well as 10 sqm on plan) including getting out and disposal of excavated earth, all works up to any lead and lift, as directed b y the Engineer-in-Charge :

-

-

-

... More
Stairs, (excluding landings) except spiral-staircases

29

23766

-

... More
RETRACTABLE CORROSION COUPON HOLDER, 4" to 30" pipe dia

4

11181

-

... More
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15 Degree landings, balconies, shelves, chajjas , lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cos t of centering, shuttering, finishing and reinforcement, with :

-

-

-

... More
8" SORF 150#

16

37967

-

... More
Using Grade 'A' sealing compound. [Note: Unit "CM" shall mean "PER CENTIMETRE DEPTH PER CENTIMETRE WIDTH PER METRE LENGTH"].

200

868

-

... More
Solid State Decoupling Device

62

529729

-

... More
Range of two half stall urinals with 5 litre P.V.C. automatic flushing cistern

1

18463

-

... More
Small lintels not exceeding 1.5 m clear span, moulding as in cornices, window sills, string courses, bands, copings, bed plates, anc hor blocks and the like.

715

268195

-

... More
Disposal of building rubbish/ malba/ similar unserviceable, dismantled or waste materials by mechanical means, including loading, tr ansporting, unloading to approved municipal dumping ground or as approved by the Engineer-in-Charge, beyond 50 m initial lead, for a ll leads including all lifts involved.

16

2925

-

... More
ALUMINIUM WORK :

-

-

-

... More
1",800#,W/W, A/G BS-1873 GLOBE Valve

6

24794

-

... More
6"x2" - 300# Unequal Tee

6

19717

-

... More
1 light point controlled by 1 switch.

30

44311

-

... More
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15 Degree landings, balconies, shelves, chajjas , lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cos t of centering, shuttering, finishing and reinforcement, with :

-

-

-

... More
Installation of Stand Post Type double way fire hydrant fitted with 2 Nos of single landing valve complete as per IS: 5290 alongwith 4" x 150# WNRF Flange

12

76832

-

... More
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level :

-

-

-

... More
Supply and installation of IDF (intermediate distribution frame) / Distribution box of 20 Pair capacity with mounting arrangement as per specifications

1

5259

-

... More
CABLE TRENCH: Excavation in unpaved areas of earth in work sites for conventional cable trenches for a depth upto 1.5 metres inclu ding shoring, strutting etc. (if necessary), backfilling the trench, job complete in all respects, including all labour and ma terials complete as per drawings, specification and directions of Site Engineer / Engineer-in-Charge

4400

3461350

-

... More
Copper Cable size 1cx25 sq.mm Armoured

200

55389

-

... More
FROM 751 METER TO 1000 METER (with OFC conduit)

-

-

-

... More
FROM 501 METER TO 750 METER (with OFC conduit)

-

-

-

... More
"Dismantling of Piping (Underground): Dismantling the existing under ground piping, locating, retrieving including excavating the pr oper trenches by cutting the pipes without damaging other portions of work. The job includes evacuation of the contents of the pipi ng, cutting the pipes to required sizes as directed, taking out valves, flanges, tees, bends, gaskets, nuts, bolts etc., handling, t ransporting and storing at owner's designated store in safe manner to avoid damage including supply of all labour, materials, equipm ent consumables etc. necessary to perform and complete the work in all respects as per drawing, instructions of the Site Engineer / EIC. (Payment shall be made on the linear measurement of dismantled piping including bend, tees, reducers etc.). Note : The contractor shall indicate the piping system to be dismantled and shall take specific approval from the Site engineer befo re dismantling of pipe.Certain redundant pipes which in the opinion of the Owner need not be retrieived, those items shall not be di smantled."

1

31783

-

... More
FLP/ WP Junction Box, Type C including FLP/WP double compression type glands and plugs, as per tender specifications. (Bottom entries: 1 No. 1 ¼' NPT (suitable for 40CX1.5sqmm) and 1 No. 1" NPT (suitable for 12CX1.5sqmm) Left side entries: 1 no. 1" NPT (suitable for 12CX1.5sqmm) & 3 nos. ½" NPT (suitable for 4CX1.5sqmm) Right side entries: 2 nos. 1" NPT (suitable for 12CX1.5sqmm) & 2 nos. ½" NPT (suitable for 4CX1.5 sqmm)

14

112841

-

... More
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :

-

-

-

... More
Providing & Laying Concrete sheathing on the carrier pipe i.e., continuous concrete coating (mix 1:1.5:3) using specified (approved) wire mesh reinforcement as per approved drawing and technical specifications, including supply of cement, steel wire mesh, aggregate, sand, shuttering and all other materials, consumables, inputs, equipment for concrete sheathing required to complete the job, testing of concrete coated pipes etc. and as per direction of Engineer-in-Charge. NOTE: I) Payment shall be made for the actual length of pipe coated with concrete. Ends of pipe left uncoated/ shall not be considered in the concrete coating length II) The rates shall include compensation for additional hardship caused in handling and/ or lowering the pipe with concrete coating. The above item shall be executed at the discretion and directions of Engineer-in-Charge. III) The rates shall include the concrete sheathing / coating over weld joints in order to arrive at continuously concrete coated pipeline. This weld joint concrete sheathing / coating shall be applied after the hydrostatic pre-test.

-

-

-

... More
" Dismantling of Piping (Aboveground) and Equipment: Dismantling of existing over ground piping works of all types and sizes by openi ng flange joints or by gas cutting/ cold cutting or any other approved suitable means without damaging other portions of work. The j ob includes evacuation of the contents of the piping, cutting the pipes to required sizes as directed, taking out valves, flanges, t ees, bends, gaskets nuts, bolts etc. attached supports alongwith any instruments such as pressure gauge, temperature gauge etc. hand ling, transporting and storing at owner's designated store in safe manner to avoid damage including supply of all labour, materials, equipments, consumables etc. necessary to perform and complete the work in all respects as per drawings, instructions of the Site E ngineer / EIC (payment shall be made on linear measurement of dismantled piping including bends tees etc.). Note : The contractor shall indicate the piping system to be dismantled and shall take specific approval from the Site engineer befo re dismantling of pipe. Certain redundant pipes which in the opinion of the Owner need not be retrieived, those items shall not be d ismantelled."

2

42864

-

... More
Fog Nozzle

2

15554

-

... More
For 30 Users

1

182574

-

125

67242

-

... More
4" 600# 90 deg LR Bend

40

92087

-

... More
Providing and fixing 12 mm thick Elevational Brick Tiles for facia, vertical face of walls, etc. at all levels and locations laid ov er and including a backing coat of 15 mm thick cement mortar (1 cement : 3 sand) and joints filled with coloured cement of same colo ur as tiles complete in all respects inclusive of cost of all labour, materials, tools, tackles etc. as per specification and direct ions of the Engineer-in-Charge.

144

245119

-

... More
EARTHWORK :

-

-

-

... More
6" WNRF 600#

75

860839

-

... More
25mm x 3 mm copper flat

300

249131

-

... More
Supply of plugs- flame proof and weather proof including EP/WO certificates

-

-

-

... More
4"x ANSI 600# F/F BS-1873 GLOBE Valve

20

1162488

-

... More
Installation and commissioning of wall mounted DCDB including supply of all cable end lugs, cable glands, fittings & fixtures and al l other required accessories, tools and tackles complete in all respects as per directions of Site Engineer/Engineer-in-charge. Item includes supply and termination of 2 runs of 1cx25 sq. mm copper cable for Battery Bank

-

-

-

... More
Tree Plant

6

59

-

... More
6" x 150#/300#/600#/900# Insulating Coupling

3

25852

-

... More
Size of Tile 800x800 mm

4

9517

-

... More
Supplying and providing non-shrinkable cement grout (SHRINKKOMP 20 or any other equivalent approved brand) for grouting holding down bolts in pocket holes for equipment foundation, including necessary surface preparation mixing of grout, curing as per manufacturer 's recommendation/ specification and directions of the Engineer-in-Charge. [Note: This item shall be operated under specific instruc tions of the Engineer-in-Charge]

3843

327317

-

... More
All works above plinth level upto floor V level

25

322698

-

... More
15 mm nominal dia pipes

5

2697

-

... More
15 mm cement plaster on the rough side of single or half brick wall of mix :

-

-

-

... More
Constructing Brick Masonary catch pit in cement mortar 1:4 (1 cement : 4 coarse sand) including necessary excavation, 200mm thick fo undation concrete 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 40mm size) and inside and top plastering (15mm thic k) with cement mortar 1:4 (1 cement : 4 coarse sand) finished with a floating coat of neat cement making necessary connections to dr ains inclusive of all labour, material, equipment, etc., all complete as per drawing, specifications and directions of the Engineer -in-Charge :

-

-

-

... More
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, includ ing painting of fittings and brackets, cutting and making good the walls wherever require :

-

-

-

... More
Carrying out air drying of the pipeline system as per specification and direction of Engineer-in-Charge including supply of all labour, materials, equipments, instruments, pigs, barrels etc. complete in all respects.

-

-

-

... More
450 mm x 450 mm rectangular section radial drain.

5

16745

-

... More
Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per directions of the Engineer-in-Charge.

5

8734

-

... More
Station : Distributed type shallow

2

877444

-

... More
4", 600#/900#, F/F

30

237392

-

... More
Cement mortar 1:6 (1 cement : 6 coarse sand)

8

64866

-

... More
CONCRETE WORK :

-

-

-

... More
Control cables (T&I) : OD upto 20 mm

7300

659660

-

... More
12" NB - Single Cut Joint

1

15052

-

... More
Lightining Arrestor:

-

-

-

... More
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :

-

-

-

... More
6.625" OD x 0.280" WT ASTM A 333 Gr. 6 PIPE

450

2284893

-

... More
Supply-CSW Electrical

-

-

-

... More
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in d epth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5m.

700

202460

-

... More
2" WNRF 600#

180

170982

-

... More
Providing and fixing first quality ceramic glazed wall tiles conforming to IS:15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by the Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey ce ment slurry @ 3.3 Kg/sq.m., including pointing in white cement mixed with pigment of matching shade complete.

74

100397

-

... More
C.P. Brass (Ref. Make: JAQUAR, Model: Cat. No.-1151 or approved equivalent).

3

2306

-

... More
50 to 100 mm average compacted thickness with bitumen of grade VG-30 @ 5% (percentage by weight of total mix) and lime filler @ 2% ( percentage by weight of Aggregate) prepared in Batch Type Hot Mix Plant of 100-120 TPH capacity.

12

159036

-

... More
FLOORING :

-

-

-

... More
Power cables LT : OD upto 20 mm

2800

114648

-

... More
1 NPS (1.315" OD x 0.179"/ 0.250" WT) ASTM A106/ A333/ A53 Pipe

110

186782

-

... More
Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to IS:15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of c ement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 Kg/sq.m. including grouting the joint with white cement & matching pigments etc. complete :

-

-

-

... More
6.625"

30

7788

-

... More
Rescuscitor

1

6309

-

... More
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto pli nth level :

-

-

-

... More
Dismantling of flexible pavement (bituminous courses) by mechanical means and disposal of dismantled material up to a lead of 1 kilo metre, as per the directions of Engineer-in-Charge.

4

1692

-

... More
Control cables (T&I) : OD above 20 mm and upto 30 mm

4000

414699

-

... More
Two or more coats on new work

4297

727915

-

... More
Cable marker

14

16612

-

... More
Conducting Close Interval Potential Logging Survey at an interval of 1 m over the buried line in the right of way including the cost of all competent manpower, transportation and camping facilities etc. to their employees, materials, test instruments, equipments, consumables etc., required for the survey as per the standard specifications, and approved procedures identification of areas/locati ons where coating repair is required alongwith suggestion for remedial measures etc. including the submission of draft reports in 2 sets and incorporation of owner's comments in the draft report and final reports in 3 sets including one soft copy containing the su rvey results in the graphical as well as tabular forms computerised colour print and complete in all respects and directions of Site Engineer / Engineer-in-Charge.

-

-

-

... More
Foundations, footings, bases for columns

52

19505

-

... More
Uprooting weeds from the trenched area after 10 to 15 days of its flooding with water including disposal of uprooted vegetation.

50

330

-

... More
Positive Pressure type self containing Breathing Apparatus

1

6309

-

... More
MASONRY WORK :

-

-

-

... More
Installation of Thermal Relief Valve: 1" X 1" F/F Thermal Relief Valve : Taking delivery of valves of all types and pressure rating from the designated location within station premises, transporting the same to site, erecting above ground on preconstructed founda tions or underground including earth work in excavation and filling for under ground valves at elevations specified in the drawings, priming and painting of above ground valves, PU Painting of under ground portions (if applicable) or flood coating and wrapping of under ground portions (if applicable) including all inputs, labour, material and consumable (other than those specifically undertak en to be supplied by the owner) and completing the work in all respects in accordance with the drawings, manufacturer's installation instructions and specifications and instructions of the Site Engineer / EIC.

40

94164

-

... More
"CAUTION BOARD: Supply and installation of vitreous enamel caution boards suitable for 440 V/11KV/6.6 KV as per IS 255 including fixing on the wall with all the required hardware etc. complete in English / Hindi/ Local Language."

17

43170

-

... More
Safety Helmet

20

8873

-

... More
Cement mortar 1:6 (1 cement : 6 coarse sand)

660

6596973

-

... More
Supply of XLPE insulated , PVC sheathed cable, 1100 V grade conforming to IS: 7098 (P-1) as per specifications and approved make

-

-

-

... More
Power cables LT : OD above 20 mm and upto 40 mm

3620

212768

-

... More
6" SWMG ANSI 600#

100

71272

-

... More
1:1.5:3 [1 cement : 1.5 coarse sand (Zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived fr om natural sources]

1342

13639677

-

... More
1" 300# Equal Tee-ASTM A420 Gr.WPL6

10

3492

-

... More
300 mm dia

60

187426

-

... More
Fasteners for Flanges 1" x 300# (0.625" Dia. X 3.5" Length)

128

8911

-

... More
10" x 150# 45° LR Bends

4

22514

-

... More
Supplying and stacking of good earth at site including royalty and carriage up to any lead complete. [Note: Volume of earth measured in stacks will be reduced by 20% for payment].

16

11575

-

... More
Providing and fixing C.P. brass Towel Ring 300mm diameter, fixed to P.V.C. cleats with C.P. brass screws, etc. complete.

3

5315

-

... More
ER Probe Extension Adapter

1

24468

-

... More
2", 600#/900#, F/F

16

63833

-

... More
Wall mounted fan: 12" Oscillating wall mounted bracket fan, noiseless, plastic moulded construction, rotary device for 3 step speed control integrated unit of approved make with all accessories complete in all respect.

8

79131

-

... More
6.625"

30

25842

-

... More
Providing and fixing white vitreous china pedestal type water closet (European type) (Ref. Make: HINDWARE, Model: Cat No.-20058 or e quivalent approved) with seat and lid, 10 litre low level white vitreous china dual flushing cistern (Ref. Make: HINDWARE, Model: Ca t No.-21028 or equivalent approved) & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with spe cials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and bracket s, cutting and making good the walls and floors wherever required :

-

-

-

... More
Water curtain nozzle

2

5590

-

... More
Painting foundation concrete (RCC) with hot bitumen of grade VG-10 @ 17 Kg/10 sqm including cleaning the foundation concrete with br ushes etc. complete in all respects inclusive of cost of all labour, materials, tools, tackles etc. as per drawings, specifications and directions of the Engineer-in-Charge.

629

428639

-

... More
"EARTHING PLATE: Supply & Installation of G.I. earthing plate as per standard drawing outside the buildings. The item also includes grouting of the plate as shown in the drawing. The item should be complete in all respect including all materials, tools, tackels etc. and as per direction of EIC / Site engineer."

36

65877

-

... More
Providing and fixing white vitreous china pedestal type water closet (European type) (Ref. Make: HINDWARE, Model: Cat No.-20058 or e quivalent approved) with seat and lid, 10 litre low level white vitreous china dual flushing cistern (Ref. Make: HINDWARE, Model: Ca t No.-21028 or equivalent approved) & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with spe cials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and bracket s, cutting and making good the walls and floors wherever required :

-

-

-

... More
Vertical load testing of piles in accordance with IS:2911 (Part-IV) including installation of loading platform by Kentledge/ Anchor piles method and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per sp ecification & the direction of the Engineer-In-Charge. [Notes : (1) Initial and Routine Load Test shall not be carried out by Dynami c method of testing. (2) Testing agency shall submitt the design of loading platform for the approval of the Engineer-in-Charge.] :

-

-

-

... More
Measuring, recording and submitting the cathodic protection readings along the entire pipeline by repeated adjustments of the settin gs of the CPTR/CPPSM units etc as per specifications for achieving full/maximum protection of all the stretches as per the criteria of protection mentioned in the specifications. Measuring the relevant readings at the cathodic protection stations and "pipe to soi l potential" readings at all the test lead locations along the pipeline including the CP station parameters like current(AC/DC), vo ltage(AC/DC),circuit resistance,battery voltage/current etc.,preparing and submitting pipe to soil potential profile, graphs and ot her data pertaining to the cathodic protection of the pipeline,job complete in all respects as per specification and instructions o f Site Engineer / Engineer-in-Charge, including cost of all labour, instruments and services rendered.

-

-

-

... More
6"x3" 600# Unequal Tee

1

6888

-

... More
Duplex (2 port) Face plate (Network I/O point) (white/ cream colour) for Local Area Network including RJ45 I/O, modular plate & switch box/ gang box for fixing the face plate.

32

17701

-

... More
Centering and shuttering including strutting, propping etc. and removal of form for all heights :

-

-

-

... More
Supply, installation, testing of earthing system consisting of 6 earth pits of perforated GI pipes earthing electrodes and copper plate terminal block including construction of chamber using cement concrete with earthing pit cover and frame, supply of charcoal, salt etc including supply of interconnecting cables / strips including necessary welding etc complete as per drawings, specifications and directions of the site engineer, including cost of tools, materials etc complete in all respects as per drawing The job shall also include testing of each earth pit and the entire earthing system on whole. (Note: Earthing for field instruments shall be provided from Station earth grid covered in Electrical SOR.)

2

216917

-

... More
Supply of all materials necessary for fabrication and installation of kilometre posts, direction markers and warning signs at the locations as per specifications, excavating & grouting in cement concrete 1:3:6, and all other works necessary for fabrication & installation of the markers including cleaning, priming & applying two coats of coal tar based epoxy paint on underground portions, supply and application of one coat of primer and two coats of epoxy paint of approved colour and quality on overground portion, stencil letter cutting for number, direction, chainage etc. and restoration of site to original condition and all other acts, deeds, matters and things and work, labour, inputs and materials/ consumables necessary to perform and complete the work in all respects as per approved drawing & specifications and as per direction of Site Engineer / Engineer-in-Charge.

-

-

-

... More
Providing and laying factory made chamfered edge interlocking Cement Concrete paver blocks in foot path, park & lawns driveway or li ght & traffic parking etc. of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in req uired colour & pattern over 50mm thick compacted bed of course sand, compacting and proper embedding/laying of inter locking paver b locks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand, all complete as per manufacturer's specifications & directions of the Engineer-in-Charge :

-

-

-

... More
Supplying, fabricating and fixing M.S. structural steel work made of joists, tubes, pipes, channels, angles, plates, flats, bars etc., for struts, chain link fencing posts as per drawing including gate, ladders, safety grills, walkways, collapsible gate, signboards, supports for cable trench, cable racks, cable tray support, chequered plates, push button control posts, supporting structures, making slots for barbed line, wire hoisting, placing in position, embedding in concrete, applying two coats of epoxy paint "EPILUX 155" High Build Enamel over a coat of EPILUX 610 Primer of M/s Berger or any other approved equivalent make as per manufacturer's recommendation, complete in all respect including cutting to required size welding of joints, fixing anchor plates,bolts, theading, nuts, washers, sleeves etc. and necessary lettering of approved pattern on main gate, signboards etc.complete in all respects inclusive of cost of all labour, materials, tools, tackles etc. as per drawings, specifications and directions of the Engineer-in-Charge. (excluding the cost of concrete work).

39.33

5854495

-

... More
"Radiographic Inspection: Inspection of welding by Digital Radiography (CR) or by conventional film radiographic method on all types of piping including processing of images/ films and interpreting the results of weld quality and reporting the same to the Site Eng ineer together with recommendations as to the acceptability or otherwise of the welds, submitting the finished radiographic films as may be approved or directed by Engineer-in-Charge inclusive of supply of all pesonnel, labour, materials, equipment, consumable, in puts, etc. and providing all services complete in all respects as envisaged in the contract documents. Note: i) Payment will be on the basis of number of welds of the respective size radiographed and shall be all inclusive for the complete job of radiographic inspection as envisaged in the contract document. ii) Radiography not involving full girth weld will be paid at 50% of the rate for full girth weld for the respective size. iii) For set-on type branch welding, the rate for radiography will be as applicable to the branch pipe size. iv) Repeat radiography of individual welds due to defective films or repair of welds shall be done at contractor's cost. v) In case where radiography is not possible, verification by utrasonic testing shall be done at contractors cost., vi) Magenetic particle inspection as and where required shall be done at Contractors cost. vii) In case of conventional film radiography, all films shall be digitised and submitted to EIC/ Site Engineer in USB drives. viii) In case of Digital/ Computed Radiography, native files along with image/ pdf files shall be submitted to EIC/ Site Engineer in USB drives."

-

-

-

... More
In all kinds of soil

7627

1826431

-

... More
2.375" OD x 0.218" WT ASTM A 333 Gr. 6 PIPE

200

334884

-

... More
Mutual Interference Survey

85

820297

-

... More
2" NB Pipe Joints RT

480

369859

-

... More
20 KVA, 415V, 3 Phase

5

3071652

-

... More
6" NB Pipe Joints RT

430

717971

-

... More
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut Granite (of any colour and s hade) for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour an d texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matc hing pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels :

-

-

-

... More
6"x ANSI 300# F/F BS-1873 GLOBE Valve

2

114260

-

... More
Supply of GPS handheld device to note coordinates as per specifications

1

52628

-

... More
Providing and laying factory made chamfered edge interlocking Cement Concrete paver blocks in foot path, park & lawns driveway or li ght & traffic parking etc. of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in req uired colour & pattern over 50mm thick compacted bed of course sand, compacting and proper embedding/laying of inter locking paver b locks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand, all complete as per manufacturer's specifications & directions of the Engineer-in-Charge :

-

-

-

... More
2" Spectacle Blind 300# F/F

1

6731

-

... More
6", 150#/300#, F/F

6

59351

-

... More
Above ground piping for Fuel line / Air line: 1.315" ODx 0.179" WT ASTM A 106 / A53/ API 5LGr B Pipe: Taking delivery of pipes, pip e fittings, steel flanges, spiral wound metallic gaskets & fasteners from designated location within station premises, transporting the same to site, fabrication and erection of above ground piping including cutting, edge preparation, bending, threading, lining up, welding and installing pipes and pipe fittings, flanges, elbows, equal and reducing outlet tees, concentric reducers, drain fun nels, vent pipes and tapping for instruments such as pressure gauges, thermal relief valves, thermowells etc., installing above ground at all elevations connecting with equipment nozzles, valves, vessels, in line instruments etc., welded and threaded pipe line of different pressure ratings, flushing pipes by water after cleaning by compressed air including air cleaning prior to install ation of valve by card board/ Tin blasting method, hydrostatic testing of each section to the specified pressure, draining the water , tie-in, final cleaning-up and disposal of wastes and surpluses including providing all inputs such as labour, material, equipments and consumables necessary to perform the work (other than those specifically under taken by the owner in this contract).completing the work in all respects in accordance with the drawings, specifications and instructions of Site Engineer / EIC.

45

42533

-

... More
Routine Test (Test Load 1.5 times the Safe Capacity) [Note: Unit "EA" shall mean "PER TEST"]

1

26427

-

... More
2 light points controlled by 1 switch

80

145092

-

... More
Supplying and fixing circular/ hexagonal M.S. Sheet ceiling fan box with clamp, 140 mm internal diameter, 73 mm height, 3 mm thick r im bottom, and top lid of 1.5 mm thick, M.S. sheet lids shall be screwed into the M.S. box by means of 3.0 mm diameter round headed screws, clamp shall be made of 12 mm diameter M.S. bar bent to shape as per standard drawings with over all length as 80 cm complete in all respects inclusive of cost of all labour, materials, tools, tackles etc. as per drawings, specifications and directions of t he Engineer-in-Charge.

20

4536

-

... More
Up to 50 tonne capacity pile. [Note: Unit "EA" shall mean "PER TEST"]

1

26427

-

... More
Filling the excavated earth to required grade, level & profile in low lying areas including watering, ramming, compacting at optimum moisture content to 90% of Proctor's density consolidation by rolling with 8 to 10 tonne power roller in layers not exceeding 20 c m thickness, including clearing the area by cutting of shrubs, bushes, grass, vegetation, debris etc. stacking and disposing out of plot area to an unobjectional area as directed by Engineer-in-Charge complete in all respects inclusive of cost of all labour, mate rials, tools, tackles etc. as per drawings, specifications and direction of the Engineer-in-Charge.

328

70309

-

... More
INSTRUMENTATION JOBS FOR MOTOR OPERATED VALVES (MOV)/ROSOV/ROV - Carrying out the instrumentation and control system jobs on the alr eady erected actuator assembly of motor operated valves (MOV)by making the necessary cable connection at field and control panel end (excluding the supply of cables) calibrating the control components, adjusting the limit switches, testing the whole assembly as p er drawings specifications and direction of the engineer in-charge/site engineer complete in all respect, including supply of suitab le size non-flame-proof cable glands, ferruls, drilling/cutting of plate for fixing glands at Control Panel end and the cost of all labour, tools, glanding, ferruling, consumables etc.

36

277040

-

... More
Close Interval Natural Potential Logging Survey

85

528272

-

... More
6.625"

100

47200

-

... More
Providing and fixing Stainless Steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, b uffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts comple te, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of require d size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of the Engineer-in-Charge. [Note : For payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, f asteners etc.]

730

553165

-

... More
WBM ROAD / CONCRETE BREAKING : WBM Road/concrete breaking for cable trenches including required shoring strutting etc., and repairin g of the road/dyke to original condition and disposing off excess materials (within the work site) job complete in all respe cts including the cost of labour, tools, materials, load, lift hire charges of equipments, if any, complete as per drawings, sp ecification and directions of Site Engineer / Engineer-in-Charge

258

1329894

-

... More
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundations and plinth in :

-

-

-

... More
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fille ts, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering , shuttering, finishing and reinforcement, with :

-

-

-

... More
Supplying and laying flat brick soling in foundation trench, in floors, garages, sumps, etc., with bricks of class designation 50 la id to proper slope, level and grade etc. filling of the joints with sand etc. complete in all respects inclusive of cost of all labo ur, materials, tools, tackles etc. as per drawings, specifications and directions of the Engineer-in-Charge.

3241

2659512

-

... More
Providing and laying damp-proof course 50 mm thick with cement concrete 1:2:4 [1 cement : 2 coarse sand (Zone-III) derived from natu ral sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources]

127

70055

-

... More
Providing and laying 52 mm thick cement concrete flooring with metallic hardner topping, under layer of 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer of 12 mm thick metallic concrete hardne r consisting of mix 1:2 (1 cement : 2 stone aggregate 6 mm nominal size) by volume with which metallic hardening compound such as IR ONITE NO. 1 of IRONITE CO. OF INDIA LTD. or aproved equivalent mixed in the ratio 4:1 (4 parts of cement : 1 part of metallic floor hardening compound of approval quality) by weight, inclusive of cost of finishing, labour, material, equipment, etc. as per specific ations and directions of the Engineer-in-Charge.

121

157010

-

... More
Fasteners for Flanges 4" x 600# ( 0.875" Dia. X 7.75" Length) - extended stud length for flanges with spectacle blind

120

41064

-

... More
Providing and fixing 15mm diameter C.P. brass tap as per following with C.P. brass flange including cutting & making good the walls wherever required, etc. complete in all respects inclusive of cost of all materials, labour, tools, tackles etc. as per specificatio ns and directions of the Engineer-in-Charge :

-

-

-

... More
8"x6" 600# Unequal Tee

4

30410

-

... More
8" x 150# 90° LR Bends

2

7837

-

... More
Type IV DIstribution Board: Double Door Translucent Euro DB of Havells or approved make, having 100 A TPN Copper Bus bar, 1x63 A TPN MCB , 1x63 A RCCB (100 mA Sensitivity), 9x6A SP MCB & 6x20 A SP MCB as per specification.

7

683963

-

... More
10 SUPPLY

-

-

-

... More
Providing and laying Polished Granite stone slab (Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent) flooring in required de sign and patterns, in linear as well as curvilinear portions of the building, all complete as per the architectural drawings, with 1 8 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand), laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade, including rubbing, curing and polishing etc. al l complete as specified and as directed by the Engineer-in-Charge.

29

134674

-

... More
12" SORF 150#

2

11851

-

... More
Supply and installation of IDF (intermediate distribution frame) / Distribution box of 10 Pair capacity with mounting arrangements as per specification.

1

5343

-

... More
6" NB Piping

2

11719

-

... More
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in d epth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5m.

87

25162

-

... More
Providing and laying Non Pressure NP-3 class (Medium duty) R.C.C. pipes including collars/ spigot jointed with stiff mixture of ceme nt mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete :

-

-

-

... More
6.625" OD

530

4984438

-

... More
Providing and fixing self cleaning S.C.I. heavy quality Floor/ Nahani trap with 100mm diameter inlet and 100mm diameter outlet, 125m m C.P. brass grating (heavy type) with or without vent arm including cost of cutting and making good the walls and floors, jointing with lead caulked joints, connecting with waste water pipe etc. complete in all respects inclusive of cost of all materials, labour, tools, tackles etc. as per drawings, specifications and directions of the Engineer-in-Charge.

20

41228

-

... More
Preparation & installation of corrosion coupon from owner supplied coated pipe. which involves preparation of sample of size 2"x4", application of pipeline coating material on the coupon, soldering 6 sq. mm. cable with coupon, sealing the soldered joint with epoxy , positioning the coupon at the pipe line depth and with in a distance of 0.5 M from the pipeline inclusive of cable & terminating t he cable in the TLP terminal. The corrosion coupons are to be installed with specified Test lead points for which prior approval to be obtained from Owner. The item also includes supply, installation / laying & termination of all XLPE, Cu cables of required length (as per site conditions) and size as mentioned in the standard drawings, toggle switch, cable glands and lugs etc., complete in all respect. All as per the direction and specification detailed in the document complete with tools, tackles & other necessary require ment for preparation of the coupon. The work complete in all respect shall include supply of all labour, tools etc complete as per t he directions of the Site Engineer.

17

44654

-

... More
STEEL WORK :

-

-

-

... More
With float glass panes of 5.50 mm thickness

93

158764

-

... More
3" BLRF 600#

2

3096

-

... More
Supply and delivery of Spiral Wound Metallic Gaskets at respective stations as per Station wise Break up of material supply and as p er technical specifications from approved vendors specified in tender document

-

-

-

... More
3"x ANSI 600# F/F BS-1873 GLOBE Valve

4

174370

-

... More
6.625"

30

9558

-

... More
Providing and fixing ball bearing for rolling shutters.

20

11057

-

... More
1:2:4 [1 cement : 2 coarse sand (Zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from n atural sources]

104

929708

-

... More
Construction of granular sub-base by providing close graded material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thicknes s with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per s pecifications and directions of the Engineer-in-Charge :

-

-

-

... More
Ceiling fan: Ceiling fan, BEE 5 star rated, with electronic regulator & other accessories and fittings etc. of approved make with 5 6" Sweep size

19

75175

-

... More
Supply and installation of Safety Shower & Eye-Wash as per drawing/ instruction of EIC

2

35171

-

... More
Foundations, footings, bases of columns, etc. for mass concrete

197

73894

-

... More
10x120 mm

204

36064

-

... More
1", 300#/900#, F/F

8

15830

-

... More
8.625" ODx 0.250" WT IS3589 Pipe

10

59000

-

... More
Wall mounted telephone socket outlet with 2 port telephone jack face plate (white/ cream colour) including RJ11 I/O. The item includes modular plate & switch box/ gang box for fixing the face plate.

32

12774

-

... More
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto pli nth level :

-

-

-

... More
Providing and applying 2.5 mm thick road marking strips (retro-reflective) of specified shade/ colour using hot thermoplastic materi al by fully/ semi automatic thermoplastic paint applicator machine fitted with profile shoe, glass beads dispenser, propane tank hea ter and profile shoe heater, driven by experienced operator on road surface including cost of material, labour, T&P, cleaning the ro ad surface of all dirt, seals, oil, grease and foreign material etc. complete as per directions of the Engineer-in-Charge and accord ance with applicable specifications.

75

59978

-

... More
Providing and fixing self cleaning S.C.I. heavy quality Floor/ Nahani trap with 100mm diameter inlet and 100mm diameter outlet, 125m m C.P. brass grating (heavy type) with or without vent arm including cost of cutting and making good the walls and floors, jointing with lead caulked joints, connecting with waste water pipe etc. complete in all respects inclusive of cost of all materials, labour, tools, tackles etc. as per drawings, specifications and directions of the Engineer-in-Charge.

8

16491

-

... More
Centrifugally cast (spun) iron socket & spigot (S&S) pipe as per IS:3989

57

81979

-

... More
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :

-

-

-

... More
2"x1" x Concentric Reducerx 600#

1

789

-

... More
Low temparature rubber hand gloves

6

77632

-

... More
Columns, Pillars, Piers, Abutments, Posts and Struts

3351

3237603

-

... More
Two or more coats on new work

43

6882

-

... More
With common burnt clay F.P.S. (Non-modular) bricks of class designation 7.5

1

33288

-

... More
Filling the excavated earth to required grade, level & profile in low lying areas including watering, ramming, compacting at optimum moisture content to 90% of Proctor's density consolidation by rolling with 8 to 10 tonne power roller in layers not exceeding 20 c m thickness, including clearing the area by cutting of shrubs, bushes, grass, vegetation, debris etc. stacking and disposing out of plot area to an unobjectional area as directed by Engineer-in-Charge complete in all respects inclusive of cost of all labour, mate rials, tools, tackles etc. as per drawings, specifications and direction of the Engineer-in-Charge.

41

8788

-

... More
Providing and applying fibre reinforced elastomeric liquid water proofing membrane with resilient acrylic polymers having Sun Reflec tivity Index (SRI) of 105 on top of concrete roof in three coats @ 10.76 litre/10 sqm. One coat of self-priming of elastomeric water proofing liquid (dilution with water in the ratio of 3:1) and two coats of undiluted elastomeric waterproofing liquid (dry film thi ckness of complete application/ system not less than 500 microns). The operation shall be carried out after scrapping and properly c leaning the surface to remove loose particles with wire brushes, complete in all respect as per directions of the Engineer-in-Charge .

416

227689

-

... More
6.625" in Normal Soil

10

87320

-

... More
6.625"

23

2232265

-

... More
Supply and delivery of Steel Flanges at respective stations as per Station wise Break up of material supply and as per technical spe cifications from approved vendors specified in tender document

-

-

-

... More
On W.B.M/ W.M.M. @ 0.4 Kg/sqm

250

5481

-

... More
Initial Test (Test Load 2.5 times the Safe Capacity) [Note: Unit "EA" shall mean "PER TEST"]

1

70474

-

... More
3"x ANSI 300# F/F BS-1873 GLOBE Valve

4

114261

-

... More
"Exhaust fan Supply, installation, testing of single phase 230 V, industrial type heavy duty exhaust fan of GEC/Usha/Crompton Greaves or of appro ved make fitted/ provided with louvres, supports etc. including making the required opening on walls, fixing and connecting the wire s etc. including earthing the body of the fan, making good the opening on the wall etc. complete as per specifications, drawings and direction of Site Engineer including the cost of all labour, tools, materials etc. complete."

-

-

-

... More
Fire Bucket

10

4920

-

... More
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, includ ing painting of fittings and brackets, cutting and making good the walls wherever require :

-

-

-

... More
WATER SUPPLY :

-

-

-

... More
6.625"

86

1551629

-

275

192509

-

... More
2"x ANSI 600# HOV W/W API 6D Ball

20

1026452

-

... More
Providing & fixing galvanized chicken wire net 20 Gauge, 20 mm mesh size in plastering work at the junction of RCC Columns/ Beams & brickwork as directed by the Engineer-in-Charge.

461

130239

-

... More
GI Cable Conduit: Supply, erection & installation of cable conduits made up of GI pipes of medium class 'B' subject to owner's appro val in trenches (already made), on walls, concrete structure etc., including supply and installation of all the necessary pipe fitti ngs such as bends, sockets, elbows, tees etc., bending, threading, binding, clamping, providings, spacers, plugs, packings, bushings etc., as required Job complete in all respects including the cost of all labour, tools, material etc. and as per specifications a nd directions of site engineer / Engineer-in-Charge:

-

-

-

... More
1 NPS (1.315" OD x 0.179"/ 0.250" WT) ASTM A106/ A333/ A53 Pipe

265

268922

-

... More
Centering and shuttering including strutting, propping etc. and removal of form for all heights :

-

-

-

... More
600 VA UPS with 15 minutes battery back-up for LAN switch

3

28302

-

... More
1:3:6 (1 cement : 3 coarse sand (Zone-III) derived from natural sources : 6 graded stone aggregate 40 mm nominal size derived from n atural sources)

18

145211

-

... More
Copper cable as per specifications - 10 Sq.mm

110

24698

-

... More
Spark Gap Surge Arrestor for above ground and under ground suitable for 100 kA lightening Impulse Current (10/350 micro s), rated sp ark over voltage = 1.25 kV in flameproof weatherproof enclosure Ex d IIC, IP 66 with connecting cable (EXFS 100 KU of Dehn or eq .)

15

227023

-

... More
Foundations, footings, bases of columns, etc. for mass concrete

452

169544

-

... More
8" WNRF 600#

2

33587

-

... More
Supply of permanently-lubricated HDPE pipe of 40 mm OD (as per TEC GR) with minimum pressure rating of 8 Kg/cm2 and wall thickness of 3.5 mm, along with duct accessories such as couplers, end caps, end sealing plugs, warning tape etc.

101

7586611

-

... More
2" ANSI 600# Equal Tee

15

7026

-

... More
1" 3000 Class St. NIPPLE

150

32745

-

... More
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber/ neoprene gasket et c. complete as per the architectural drawings and directions of the Engineer-in-Charge. [Note: Cost of aluminium snap beading shall be paid in basic item] :

-

-

-

... More
Painting foundation concrete (RCC) with hot bitumen of grade VG-10 @ 17 Kg/10 sqm including cleaning the foundation concrete with br ushes etc. complete in all respects inclusive of cost of all labour, materials, tools, tackles etc. as per drawings, specifications and directions of the Engineer-in-Charge.

425

289621

-

... More
" Development of As Built Drawings, Data Sheets etc.: Development of as built drawings, data sheets, system details covering all addit ional facilities incorporated under this project in the station and furnishing them as reference document. Additionally, electronic copy of the documents shall also be furnished in USB drives to EIC/ Site Engineer"

2

646781

-

... More
Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dump ing ground within 50 metres lead.

1

51

-

... More
"Point wiring Supplying, installation and testing with 1.5 Sq.mm stranded PVC insulated copper conductor wires for phase & neutral of 650V grade i ncluding earthing by providing 1.5 Sq.mm earth insulated continutity wire of copper in PVC conduit (Supply & installation of PVC con duit covered elsewhere in SOR) recessed on wall/ceiling/ false celing including supply & installation of switch boxes,junction boxes , pull boxes, bushes, screws, check nuts, bends, modular switches and sockets . The circuit wiring with 4 Sq.mm PVC copper wire fro m D.B. to switchboard as required is also in the scope of the contractor: "

-

-

-

... More
12" BLRF 150#

2

15668

-

... More
GENERAL WORKS :

-

-

-

... More
CP Readings

85

50530

-

... More
Earth work in surface excavation (not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan) in all kinds of soil including getting out and disposal of excavated earth up to all lead and lift, as directed by the Engineer-in-Charge.

12500

1523380

-

... More
Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS:6315, having brand logo embossed on the body/ plate with double spring mechanism and door weight up to 125 Kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per directions of the Engineer-in-Charge. :

-

-

-

... More
Installation of CJB / AJB as per technical specifications.

7

145202

-

... More
Supply and installation of retractable Corrosion Coupon Holder with 2" Thread-O-Ring (TOR) fitting complete with Caps, Plugs, O-Rin gs, Nipple & 2" 600#/900#full bore threaded ball valve.

3

54646

-

... More
Providing and fixing square mouth S.W. gully trap class SP-1 complete with C.I. grating, brick masonry chamber with water tight C.I. cover with frame of 300x300 mm size (inside dimension). The brick masonary chamber shall be constructed with common burnt clay F.P. S. (Non-modular) bricks of class designation 7.5. [Note: Weight of the cover shall not less than 4.50 kg and weight of the frame sha ll not be less than 2.70 kg as per standard design] :

-

-

-

... More
6.625"

1

162084

-

... More
Single pile up to 50 tonne Safe Capacity :

-

-

-

... More
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS:733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neopre ne gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural d rawings and the directions of the Engineer-in-Charge. [Note: Glazing, paneling and dash fasteners to be paid for separately] :

-

-

-

1500

270367

-

... More
DRAINAGE :

-

-

-

... More
Services- CP System Electrical

-

-

-

... More
Providing and fixing to the inlet mouth of rain water pipe PTMT (an Engineering Thermoplastic) grating square (Slit) 150 mm square w ith a height of 8 mm and weighing not less than 100 gms.

11

1454

-

... More
Laying cased crossings, by auger boring & jacking method / Horizontal Directional Drilling (HDD) method using casing pipes and 3LPE coated carrier pipes according to drawings/ specification(s) and providing all works, labour, inputs and materials/ consumables necessary to perform and complete the works in all respect in accordance with the contract, taking delivery and transportation of Owner-supplied 3LPE coated pipes and bare casing pipes to the work site from designated stockpile location, inspection of the coated pipes visually and/or with holiday detector for defects, arranging all necessary intermediate storage area required thereof till the pipes are installed in permanent position, setting out the works, aligning and welding the casing and carrier pipes, 100% radiography of weld joints of carrier pipes, field joint coating, holiday detection & repair of coating, applying a layer of Poly-Urethane Coating of min. thickness 1000 microns over a coat of suitable primer to external surface of casing pipe,and two component epoxy coating of min. thickness 600 microns for internal surface of casing pipe, excavating/ trenching and / or drilling/ boring in all kinds of soil including rocky strata, inserting the casing pipe into the bore, pre-hydrostatic testing of the carrier pipe and replacement / rectification of defects / pipes, installation of HDPE insulators on the carrier pipe, carefully inserting the carrier pipe inside casing pipe by jacking/ pushing method taking care not to damage the insulator and coated carrier pipe, sealing the ends of the casing pipe, as per procedure given in specifications, with heat shrinkable wraparound type end seal of approved make, fixing of vent pipes at the ends of the casing pipe, priming and applying two coats of coal tar based epoxy paint on underground portion of vent pipes, measuring final resistance between carrier pipe and casing, and doing preparation work necessary to produce correct resistance, applying one coat of primer and two coats of epoxy paint to all exposed and overground fittings & piping, proper compaction of backfill below carrier pipe at either ends, independently supporting the carrier pipe outside each end of the casing pipe by suitable RCC supports on firm base with neoprene rubber sheet below carrier pipe and strengthening with sand bags and proper compaction of earth below pipe, to prevent settlement of carrier pipe and damage to insulators, final clean-up and restoration of the site and disposal of wastes and surplus in accordance with the contract and supply of all materials (other than those specifically undertaken to be supplied by the Owner under contract) necessary for or in the performance of the work or for temporary or permanent incorporation in the works, and all other acts, matters and things necessary to make the pipeline ready for commissioning in all respects. NOTE: 1. The work of cased crossing will include the provision of temporary supports for existing installations in the road and/or railroads, the provision of diversions, the restoration of the railroad/ embankment to its original state, maintenance for subsidence and all other precaution(s), work(s) and/or maintenance expressed or implied in the contract. 2. The work will also include providing necessary independent support to carrier pipe outside each end of casing pipe by suitable RCC supports, proper compaction of backfill below carrier pipe at either ends and strengthening with sand bags and/ or other suitable means so as to prevent differential settlement of the casing pipe and damage to insulators, including all labour, materials etc. as per direction of Site Engineer/ Engineer-in-Charge. 3. All materials (other than the Owner-supplied materials) required for performance of the work shall be supplied by the Contractor at his own cost. 4. Casing end seal shall be of approved type only and shall be installed by skilled personnel as per approved procedure and demonstration by manufacturer's representative (to be arranged by mainline contractor) 5. Carrier pipe to be brought to the desired level of crossing by providing natural gradient to trench botom from sufficient distance and avoiding field bends so as to keep provision for any future widening of Railway/ Highway. 6. Casing insulators (made of HDPE) shall be interlocking type, free from metallic nuts & bolts

-

-

-

... More
Laying of Owner-supplied pre-coated mild steel line pipes, including arranging all additional land/construction corridor, beyond Owner's ROU/ROW, required for Contractor's storage, fabrication, access for construction site, movement of construction equipment etc., receiving and taking over Owner-supplied materials, handling, transportation etc. from Owner's issue point to work site, stringing along Right of Way (ROW)/ pipeline corridor, providing labour, equipment and supply of other inputs & materials/ consumables necessary to perform and complete the work in all respects in accordance with the contract including, but not limited to, the following works:- - Taking delivery of pre-coated/ bare pipes from the designated stockpile location (loading of pipes onto pipe trailors placed inside stockpile by mainline contractor shall be done by Owner's authorized agency), including placing of pipe trailors for taking delivery of pipes from designated stockpile, carrying out holiday detection and verification of pipes at the time of taking delivery), transportation of pipes to ROW/ work site/ Contractor's storage location etc., - Clearing and grading of ROW/ pipeline corridor, cutting of trees, vegetation etc. including keeping record of trees cut, including de-watering etc., - Stringing of pipes along ROW including providing straw bags/ soft padding below pipe (in Rocky areas requiring blasting for preparation of trench, pipes shall be strung after the blasting operation and clearing of trench as per instructions of Site Engineer/ Engineer-in-Charge), - Trenching to all depths to maintain clear earth cover as per specification and to fit minimum bend radius, by excavation in all kinds of terrain & soil, including stripping top soil to a depth of 30cm to the full anticipated width of the ditch and storing this material separately along the ROW to allow re-depositing of the same on top of the backfilled ditch (in cultivable and other areas specially designated by Owner), - Carrying out repair of pipe & coating defects for defects occurring after "taking over" of pipes from Owner, replacement in the case of non-repairable defects and repairing damages to pipe coating including defects/ damages occurring during transportation & handling, - Aligning, bending, lining up, cutting and beveling (as required) of pipes for field adjustments, welding (manual / semi-automatic / automatic), physical inspection of all weld joints by qualified welding engineer/ inspector & carrying out repair of weld-joints found defective, -Carrying out 100% radiographic inspection (by X-Ray) of all field weld joints, destructive testing of one weld joint in each Spread as per specification and direction of Site Engineer, including providing Crawler type Automatic X-Ray machine and external X-Ray machine and all other requisite equipment, labour, supervision, materials, approved films, approved consumables, all facilities and personnel to process, develop, examine and interpret radiographs (by qualified and experienced Radiography Inspector), providing all facilities to Owner's representative(s) for examining radiographs and other tests as required, carrying out repair of weld-joints found defective, carrying out re-radiography and other tests as required on repaired joints, etc., - Carrying out coating of all field weld joints, by qualified coating insulators, including supply of approved joint coating materials, providing all equipment, materials and consumables necessary to carry out the job as per manufacturer's recommendation, - Installation of hot-pulled bends at required locations in mainline (bends to be fabricated from Owner-supplied bare pipes) including cutting, beveling, fitment, coating the bare bend pipe with approved heat shrink sleeve coating, - Carrying out holiday detection, at specified voltage level corresponding to coating type and as per specifications, and repair of coating, if any, -Laying pipeline by open-cut method at crossings viz., cart-track, village road, metalled/ un-metalled roads, minor water courses (MWC) etc.,(except crossings identified as "Cased", "Submerged", "Shallow HDD" & "HDD" crossings ) and restoration of the crossing site to original condition including performance of additional works for strengthening of banks of water courses etc., - Lowering the pipeline in trench, tieing-in, backfilling with excavated earth and/or other suitable soil (top soil stored separately during trenching shall be backfilled on top of the ditch) as directed by Site-Engineer, - Carrying out air cleaning, gauge pigging and hydrostatic testing (to specified pressure) of the complete pipeline (excluding those HDD crossing sections not under the scope of this tender) including providing 'pre-testing' of designated sections as approved by Engineer-in-Charge, providing all equipment, pumps, fittings, instruments, dead weight tester etc. and services, supervision, labour, consumables, testing of water, supply & injection of corrosion inhibitor, locating leaks, if any, and rectification of defects attributable to Contractor, re-testing after rectification etc. and cleaning the pipeline section after successful hydrotesting, - All tie-ins, including tieing-in with HDD sections under this tender and also with HDD sections not covered under this tender (tie-ins with HDD sections not under this tender shall be paid separately as per relevant item of SOR), - Obtaining work permits/ NOC from various authorities having jurisdiction before execution of work and complying with all stipulations/ conditions/ recommendation of the said authorities - Supply and installation of 1.0 mm thickness & width (D+300) warning tape over entire pipeline as per relevant specification - Final clean-up and restoration of ROW/ construction corridor, field bunds etc., obtaining NOC from statutory authorities (as required) and obtaining NOC from respective land owners in respect of final restoration of their land etc, disposal of debris and returning surplus material to designated disposal areas/ storage location, as directed by Engineer-in-Charge, restoration of land, facilities and boundary wall etc. for facilities dismantled/ damaged by Contractor during construction, - Preparation of as-built drawings, pipe book and other records as per specifications etc., - Supply of all materials (other than those specifically undertaken to be supplied by the Owner under the contract) necessary for performance of work or for temporary or permanent incorporation in the works, and - All other acts, deeds, matters and things necessary to make the pipeline ready for commissioning and completing the works in all respects as per drawings, specifications and instructions of Site Engineer/ Engineer-in-Charge. NOTE: I) The rate quoted against this item shall include cost of excavation and backfilling of trench of standard width (as per approved drawings) in all kinds of soil for laying Mainline pipe. II)The Mainline work includes and covers the work in all types of crossings viz., roads, drains, minor water courses (MWC), low lying areas, ponds, plant area, underground utilities, pedestrian crossings, etc. except those crossings identified as "Cased", "Submerged" & "HDD" crossings for which relevant item of SOR shall be applicable. III) Concrete coating, if necessary, for laying pipelines across ponds, low lying areas etc. shall be paid separately as per relevant item of SOR. IV) Cost of all materials required in repair and/ or rectification of defective work caused due to reasons not attributable to any act or omission of the Owner shall be chargeable to Contractor account. The Owner will supply the additional materials from its designated store/ godown (insofar as constitutes Owner-supplied materials) required for the repair/ rectification work on chargeable basis. The cost of such material shall be as determined by the Engineer-in-Charge plus an additional charge of 15% of the cost of material shall also be levied. The decision of the Engineer-in-Charge, as to the cost of the material, shall be final and binding on the Contractor. VI) In the course of hydrostatic testing of the mainline section, if any defective portion/ pipe/ work is found to be due to a defect in the pipe attributable to the Owner, the Owner shall supply the additional necessary pipes at Owner issue point required for the work free of cost to the Contractor, but the Contractor shall supply all other materials and inputs at his own cost for replacement of pipe section. The Contractor shall be paid a lump sum amount for each such failure (refer relevant clause of Special Conditions of Contract of the tender documents) for the work involved in locating & identifying the defects in the mainline and in their repair/rectification as per the specification. Failure in one or more pipes in a section during a single pressurization cycle shall be considered as a single failure for the purpose of compensation for hydrostatic test failure on account of manufacturing defect. VII) Installation of the hot-pulled bends in Mainline, including cutting beveling of pipes, fitment etc., shall be inclusive in the Mainline rate. Payment for fabrication of hot-pulled induction bends, as per specifications, shall be done separately as per relevant item of SOR. The hot-pulled bends shall be coated at site with heat shrink sleeve coating. The cost of the same shall be deemed to be included in this item for Mainline laying.

-

-

-

... More
600 mm dia R.C.C. pipes

34

133625

-

... More
Filling the gap in between Aluminium/ Stone/ Wood frame and adjacent RCC/ Brick/ Stone/ Wood/ Ceramic/ Gypsum work by providing weat her/ structural non-sag elastomeric PU sealant over backer rod of approved quality as per architectural drawings and directions of t he Engineer-in-Charge complete, complying to ASTM C920, DIN 18540-F & ISO 11600 :

-

-

-

... More
4" ANSI 600# 45 deg LR Bends

2

2260

-

... More
Hand Operated siren

1

19086

-

... More
10.75" ODx 0.250" WT IS3589 FE410 Pipe

450

3707973

-

... More
Flexible Pipe :

-

-

-

... More
1:6 (1 cement : 6 fine sand)

36

13882

-

... More
Pipe size up to 2 inch NB

2

1298

-

... More
Kota stone slab flooring 25 mm thick over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigmen t to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse san d) :

263

530523

-

... More
External Work: Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water suppl y including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, t renching, refilling & testing of joints complete as per directions of the Engineer-in-Charge :

-

-

-

... More
Fasteners for Flanges 12" x 150# (0.875" Dia. X 5.50" Length)

60

10620

-

... More
With stainless steel cover plate minimum 1.25 mm thickness

17

54006

-

... More
"Fasteners for Flanges 6"" x 600# (1.0"" Dia. X 9.0"" Length) - extended stud length for flanges with spectacle blind"

192

62983

-

... More
Supply of pre-fabricated RCC (1:1.5:3) Joint Box with lid as per tender specifications

45

627707

-

... More
Providing Plaster of Paris cornice (75 mm x 75 mm) at corners of wall and ceiling as per approved design complete in all respects in clusive of cost of all labour, materials, tools, tackles etc. as per specifications and directions of the Engineer-in-Charge.

27

32351

-

... More
Wall mounted Cabinet (switching closet) for housing Networking Equipment/ CCTV hardware, patch panel & accessories including power distribution boxes, MCBs/ Isolator Switches, required installation materials as per tender specifications

3

157547

-

... More
"Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cist ern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS:2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required : "

-

-

-

... More
Integrity testing of Pile using Low Strain/ Sonic Integrity Test/ Sonic Echo Test method in accordance with IS:14893 including surfa ce preparation of pile top by removing soil, mud, dust & chipping lean concrete lumps etc. and use of computerised equipment and hig h skill trained personal for conducting the test & submission of results, all complete as per directions of the Engineer-in-Charge. [Note: Unit "EA" shall mean "PER TEST"]

1

1236

-

... More
Shrub Plant

6

29

-

... More
Installation of solid state decoupling device as per specifications including terminating the cables in the TLP box with cable lugs, sealing material, laying of cable, testing & commissioning of Zinc anodes etc. all complete with required material, excavation, bac kfilling etc. as per specification and directions of Site Engineer/ Engineer-in-Charge.

-

-

-

... More
INSTALLATION OF SURFACE MOUNTED TEMPERATURE TRANSMITTER Installation and assistance in testing & commissioning of Surface Mounted te mperature elements/temperature transmitter (TT) by by welding the weld pad on the surface of the pipe, silicon paste as per the dir ections of engineer in-charge/site engineer and drawings.

14

214352

-

... More
Providing and laying 10 mm thick white ceramic tiles over 15 mm layer of cement mortar 1:3 (1 cement : 3 fine sand) mixed with water proofing compound finished neat etc. complete in all respects inclusive of cost of all labour, materials, tools, tackles, etc. as p er drawings, specifications and directions of the Engineer-in-Charge.

50

105555

-

... More
Fasteners for Flanges 8" x 600# (1.125" Dia. X 10" Length) - extended stud length for flanges with spectacle blind

12

6471

-

... More
Providing and fixing ceramic glazed floor tiles of first quality conforming to IS:15622 (thickness to be specified by the manufactur er) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by the Engineer-in-Charge i n skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cem ent slurry @ 3.3 Kg/sq.m. including pointing in white cement mixed with pigment of matching shade complete.

18

21994

-

... More
Single Push-fit Coupler (110 mm)

20

2856

-

... More
1" 600# 90 deg LR Bend

50

18585

-

... More
1" to 1/2" Reducers

15

4490

-

... More
Neat cement punning.

625

51639

-

... More
1:3:6 (1 cement : 3 coarse sand (Zone-III) derived from natural sources : 6 graded stone aggregate 40 mm nominal size derived from n atural sources)

10

80672

-

... More
Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections.

1011

78402

-

... More
Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulde rs, in required thickness, for all leads & lifts, all complete as per directions of the Engineer-in-Charge.

5

8734

-

... More
ROOFING & CEILING :

-

-

-

... More
Foundations, footings, bases for columns

27

10127

-

... More
6 NPS (6.625" OD x 0.250"/ 0.280" WT) API 5L/ ASTM A106/ A333/ A53 Pipe

160

739718

-

... More
INSTRUMENTATION JOBS FOR PRESSURE CONTROL VALVE / FLOW CONTROL VALVE - Testing of control valve and field electronics, including fab rication of all structural supports and fittings, termination of related cables at field, panel & MCC end, after loop testing as per vendors drawing and direction of the site engineer. Mounting of junction box if any, supply of non flame proof cable glands for pa neland MCC end. The works includes tagging, labelling, glanding andferruling at both panel and field ends.

3

81436

-

... More
Single Push-fit Coupler (110 mm)

11

1570

-

... More
"STAINLESS STEEL INSCRIPTION PLATE: Supply and installation of approved quality stainless steel name inscription plates including anodising, engraving the inscriptions, providing screws, etc. for equipments viz. motors, motor control centres, switchgears, push button stations etc. as required, provi ding necessary holes tapping etc. and fixing the same complete in all respect as per the direction of Site Engineer/Engineer-in-char ge including the cost of all labour, tools etc."

40

46767

-

... More
Copper Cable size 2cx25 sq.mm Armoured

50

32454

-

... More
Coating Resistance Survey

85

171498

-

... More
In dado/ skirting on 12 mm thick mortar 1:4 (1 acid and/or alkali resistant cement : 4 coarse sand) :

1

2117

-

... More
Providing and laying autoclaved aerated cement blocks masonry with 100 mm thick AAC blocks in super structure above plinth level up to floor V level in cement mortar 1:4 (1 cement : 4 coarse sand). The rate includes providing and placing in position 2 Nos 6 mm dia M.S. bars at every third course of masonry work.

22

238350

-

... More
6 mm cement plaster of mix 1:3 (1 cement : 3 fine sand)

1366

408950

-

... More
Providing and laying design mix reinforced cement concrete of M-30 grade in roads/ taxi tracks/ runways, using cement content as per design mix, using coarse sand and graded stone aggregate of 40 mm nominal size in appropriate proportions as per approved & specifi ed design criteria, providing dowel bars with sleeve/ tie bars wherever required, laying at site, spreading, levelling to required s lope/ camber and compacting mechanically by using screed board vibrators, vaccum dewatering process and finally finishing in require d texture by floating & brooming with wire brush, including steel form work with sturdy M.S. channel sections, curing, making provis ion for contraction/ expansion, construction & longitudinal joints (10 mm wide x 50 mm deep) by groove cutting machine, providing ex pansion joints as per drawing including dowel cap, sponge, sealing tape, bitumen painting, debonding tape and filling joints with ap proved joint filler and sealants, complete all as per direction of the Engineer-in-Charge. [Notes: (1) Item of joint fillers, sealan ts, dowel bars with sleeve/ tie bars to be paid separately. (2) The item rate is inclusive of cost of dowel cap, sponge, sealing tap e, bitumen painting, debonding tape. (3) Cement content considered in M-30 is @ 340 kg/cum. Excess/ less cement used as per design m ix is payable/ recoverable separately].

-

-

-

... More
Mixing earth and sludge or manure in the required proportion specified or directed by the Engineer-In-Charge.

26

1286

-

... More
TOR fitting complete with Caps, Plugs, O-Rings, Nipple & 2" 600# full bore threaded ball valve

2

48757

-

... More
3"X2" x Concentric Reducer X 300#

2

1128

-

... More
6.625" OD

76390

154139742

-

... More
Supply of wall mounted Fibre Termination Box (FMS) suitable for 48F OFC cable as per tender specifications

3

75373

-

... More
Mainline CP : Anode bed shallow type

1

397479

-

... More
Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by vo lume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts. [Note: Cost of manure, sludg e or extra good earth if needed shall be paid separately under relevant item of SOR].

-

-

-

... More
MASONRY WORK :

-

-

-

... More
Cable Laying: Laying of all type of cables LT (PVC / XLPE / Armoured/Unarmoured/Power/ Control/ Signalling) in trenches, in cable racks, in trays, in protective pipes, poles, columns, in conduits, in panels and on structures etc.; including the supply and insta llation of all required materials such as fixing clamps, screws, cable straps, tags, etc. as required (other than the supply of the conduits, cables, pipes, cable racks, trays, poles, structures and panels) complete in all respect, including cost of all lab our, tools, consumable materials, etc. and cutting the cables in required lengths as per drawings, specification and directions of Site Engineer / Engineer-in-Charge:

-

-

-

... More
Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer's sp ecification. [Note: Unit "KG" shall mean "PER KG PER 50 KG OF CEMENT"].

1078

80278

-

... More
4" x 150# WNRF Flange Stand Post Type double way fire hydrant fitted with 2 Nos of single landing valve complete as per IS: 5290

12

210375

-

... More
Installation, laying of 2 Pair PVC insulated copper conductor un-armoured telephone cables in 16 mm/ 25 mm/ 32 mm PVC conduits from IDF through ceiling/ wall/trench and post-laying end to end testing of telephone cables. The job includes supply, installation, fixing of wall mounted telephone socket outlet with 2 port telephone jack face plate (white/ cream colour) including RJ11 I/O with modular plate & switch box/ gang box for fixing the face plate & accessories, supply and installation of PVC Conduits, all required materials such as fixing clamps, screws, cable straps, tags etc. as required complete in all respects as per specifications & scope of work, drawings and directions of Site Engineer/ Engineer-in-charge including cost of all labour, tools & tackles, materials etc.

500

94624

-

... More
Providing and fixing aluminium tubular handle bar 32 mm outer dia, 3.0 mm thick & 2100 mm long with SS screws etc .complete as per d irections of the Engineer-in-Charge :

-

-

-

... More
Erection, Installation,Testing & Commissioning of the Owner supplied high mast tower with the help of suitable tools and plants, wir ing of luminaires with all wiring materials like PVC insulated PVC sheathed flexible cable of suitable copper conductor cores of 1.5 sq. mm, lugs, MCB and all labour. Scope of work shall include erection & installation of high mast tower, cable connections, erect ion & installation of luminaries & aviation lights, lightning finial, all accessories, cables, etc., erection, foundation casting & grouting of owner supplied FLP feeder pillar, end connection termination & laying of Owner supplied cable from feeder pillar to bas e compartment of high mast complete with all materials and labour as per instruction of Site Engineer/EIC. Earthing works for High Mast tower including construction of earth pits to be operated in relevant separate item : For 30 M Height High Mast Tower

1

88097

-

... More
10.75" ODx 0.250" WT IS3589 Pipe

160

1183587

-

... More
Stainless steel liquid soap container (spring loaded push type) with lid and brackets fixed to P.V.C. cleats with C.P. brass screws, etc.

3

7939

-

... More
Flame proof, weather proof, single phase, 12" exhaust fan, IP65, Gas Group IIC of reputed make alongwith supporting frame, bolts, lo uvers, flame proof motor, including supply & installation of flameproof double compression cable glands & flame proof plugs for seal ing all spare entries, complete in all respects

5

59163

-

... More
Providing and laying 10 mm thick white ceramic tiles over 15 mm layer of cement mortar 1:3 (1 cement : 3 fine sand) mixed with water proofing compound finished neat etc. complete in all respects inclusive of cost of all labour, materials, tools, tackles, etc. as p er drawings, specifications and directions of the Engineer-in-Charge.

10

21111

-

... More
1.315" OD x 0.179" WT ASTM A 333 Gr. 6 PIPE

300

228330

-

... More
30 - 50 mm wide x 1 mm thick Copper strip

500

228330

-

... More
Composite2-CSW Electrical

-

-

-

... More
Carrying out Nitrogen Purging of the pipeline system as per specification and direction of Engineer-in-Charge including supply of all labour, materials, equipments, instruments, pigs, barrels etc. complete in all respects.

-

-

-

... More
Using Grade 'A' sealing compound. [Note: Unit "CM" shall mean "PER CENTIMETRE DEPTH PER CENTIMETRE WIDTH PER METRE LENGTH"].

175

759

-

... More
GI wire / rope 10 mm diameter

10

1971

-

... More
Preparation of beds for hedging and shrubbery by excavating 60 cm deep and trenching the excavated base to a further depth of 30 cm, refilling the excavated earth after breaking clods and mixing with sludge or manure in the ratio of 8:1 (8 parts of stacked volume of earth after reduction by 20% : one part of stacked volume of sludge or manure after reduction by 8%), flooding with water, fillin g with earth if necessary, watering and finally fine dressing, leveling etc. including stacking and disposal of materials declared u nserviceable and surplus earth by spreading and leveling as directed, within a lead of 50 m, lift up to 1.5 m complete. [Note: Cost of sludge, manure or extra earth shall be paid for separately under relevant item of SOR].

6

1811

-

... More
Supplying, providing and filling Soft Soil in trenches in hard rocky stretches (excluding additional 150mm deep rock trenching) around mainline pipe for providing a minimum padding thickness of 150mm on top as well as at bottom of the mainline pipe. In all cases where rock or gravel or moorum or hard soil is encountered in the bottom of the trench, trench padding, Rock Shield Materials and sand/soft soil bags as approved by OWNER/Engineer-in-Charge, shall be provided to safeguard the pipe coating. Padding materials shall be graded soil/other suitable material containing no gravel, rock, or lumps of hard soil. The graded soil for padding shall pass through sieve size ASTM-10 or ISO-2.00. Acceptable padding shall be placed under the pipeline before its installation and around it after installation, to establish at both sides and on top of the pipe a permanent layer of padding. The thickness of compacted padding shall be at least 150mm. The trench shall be deeper by at least 150mm. The trench shall be evenly and sufficiently padded to keep the pipe, when in place, at least 150mm above the bottom of excavated trench. NOTE: (i) Item to be operated under specific instructions from Engineer-in-Charge (ii) Cost of additional depth of 150mm trenching for this item shall be paid separetly under item for "Extra for Rock trenching"

-

-

-

... More
Carrying out the Current Attenuation(CAT) Survey at 50 meters interval by measuring current loss along the mainline pipe and using R adio Detection Instruments. Completing the entire work as per specification and EIC`s direction including all equipments with its ac cessories etc.tools, tackles, Battery transportation (Vehicle), related equipments,consumables, if any labour /manpower and any / al l relevant data collection as may be deemed necessary for carrying out the survey and interpretation /presentation of the results in cluding submission of reports complete in all respect thereof. Also locating the exact position of buried pipeline/defect of Pipelin e coating.Route mapping of the entire stretch at an interval of 10M with the help of GPS instrument (to be arrange by contractor)and submission of the hard and soft copy to the EIC.

5

39783

-

... More
"Under ground piping for Process piping (with PU/3LPE Coating): Taking delivery of bare Pipes, pipe fittings, steel flanges, spiral wound metallic gaskets & fasteners from designated location with in station premises transporting the same to site, fabrication and erection of underground piping including cutting, edge preparatio n, bending, threading, lining up and welding, excavating, trenching in all kind of soil to specific depths as indicated in drawings and installing pipes and all types of pipe fittings like flanges, elbows, equal and reducing outlet tees, concentric/eccentric reduc ers, drain funnels, vent pipe and tapping for instrument such as pessure gauges, thermal relief valves, thermowells etc., undergroun d at elevations indicated in the drawing connecting with equipment nozzles, valves, vessels, in-line instruments etc.,Cleaning expos ed steel surfaces of Bare Pipes, Pipe Joints, Fittings, Flanges,equipment and valves etc. by sand blasting or with power wire brush (wherever sand blast cleaning is not possible) free of dust, grease, mill scales etc. and applying single layer polyurethane coatin g(PU) using 100% solvent free elastomeric plyurethane/ liquid epoxy, with approved materials,Equipment etc, holiday detection of the coating, cleaning of coated pipes by water flushing after cleaning by compresed air,hydrostatic testing of each section to the spec ified pressure, draining the water, tie-in, back filling, restoration of site final cleaning up and disposal of water and surpluses, providing all inputs such as labour, materials equipment and consumable necessary to perform the work (other than those specificall y undertaken to be supplied by the owner under the contract) and completing the work in all respects in accordance with the drawing s, specifications and instructions of the Site Engineer / EIC. In case of 3LPE coated pipes, weld joints shall be PU coated. Note: 1. Thickness and Grade mentioned in the item are for reference only and may vary. Payment shall be based on OD. 2. Payment for external PU/ epoxy coating shall be done separately as per relevant SOR item."

-

-

-

... More
6" ANSI 600# 45 deg LR Bends

8

19927

-

... More
Supply of IS: 3589, Gr. Fe 410 pipes with factory coated internal coating at respective stations as per Station wise Break up of mat erial supply and as per technical specifications from approved vendors specified in tender document

-

-

-

... More
Dismantling of flexible pavement (bituminous courses) by mechanical means and disposal of dismantled material up to a lead of 1 kilo metre, as per the directions of Engineer-in-Charge.

7

2961

-

... More
Supply of Valves at respective stations as per technical specifications from approved vendors in the tender document - Thermal Relie f Valves

-

-

-

... More
Red & Green flag (Pairs) 2 nos in each colour

1

1820

-

... More
6"x2" X 300# Weld-o-let

8

21985

-

... More
Installation of surge arrestors including terminating the cables, testing & commissioning of surge arrestors etc. all complete with required material as per specification and directions of Site Engineer / Engineer-in-Charge.

-

-

-

... More
Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.

191

153249

-

... More
Electrical resistance based corrosion monitoring system consisting of following items:

-

-

-

... More
Service Valve Kit

1

451286

-

... More
Galvanised mild steel frame with packing space of Min.120x180 mm with multi diameter blocks and accessories with peeling off arrange ment to adjust cable size from 3.5mm to 99mm outer dia.

10

237223

-

... More
Earth work in surface excavation (not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan) in all kinds of soil including getting out and disposal of excavated earth up to all lead and lift, as directed by the Engineer-in-Charge.

4170

508199

-

... More
3" Spectacle Blind 300# F/F

2

18962

-

... More
Providing and fixing to the inlet mouth of rain water pipe PTMT (an Engineering Thermoplastic) grating square (Slit) 150 mm square w ith a height of 8 mm and weighing not less than 100 gms.

20

2645

-

... More
SUPPLY

-

-

-

... More
As built documentation for each station covering a) Control /signalling cable layout drawings, b) Cable trench details, c) Cable m arker details, d) Earth grid layout, e) Field instrument termination details, f) Cable schedule, g) Junction box wiring details, h) Earth resistivity measurement data, i) Field panel termination details, j) Calibration data of all instruments tested as per scope. , k) OTDR Traces of the laid OFC as applicable for respective stations

2

304399

-

... More
Up to 50 tonne capacity pile. [Note: Unit "EA" shall mean "PER TEST"]

1

26427

-

... More
Installation of OFC Joint pit markers at every joint location as per specifications, drawings and directions of Engineer-in-charge/ Site Engineer

243

352277

-

... More
Emergency Kit: Supply and delivery of Emergency Kit consisting oflisted emergency equipments as per Annexure-VII

1

1222672

-

... More
Providing and fixing aluminium round shape handle of outer diameter 100 mm with SS screws etc. complete as per directions of the Eng ineer-in-Charge :

-

-

-

... More
"Extra for rock trenching for Mainline laying (covered under relevant item of this SOR) as classified by the Engineer-in-Charge and performed by pneumatic tools or by drilling and blasting or by chiselling out including cost of all equipment, materials, labour, co nsumables & inputs to complete the work (excluding sand padding around mainline pipe which shall be paid separately) as per specific ations, approved procedure and instructions of Engineer-in-Charge. Note: 1.Payment shall be made for rock actually excavated at site or calculated based on the trench dimensions stipulated in the specifica tions / drawings, whichever is less. 2.Item shall be operated under specific instructions from Engineer-in-Charge. 3.Controlled Blasting operation shall be carried out only by authorized and trained / skilled manpower, as per approved procedure, a nd taking due care & precaution to adjoining property, people, livestock etc., with due approval from Engineer-in-Charge 4.Sand padding around mainline pipe shall be paid separately as per relevant item in SOR 5. Additional 150 mm depth of excavation to be carried out in rocky area (for pipe trench) to accommodate sand padding"

140

151984

-

... More
3" SWMG ANSI 300#

20

6277

-

... More
Supply and delivery of Steel Fasteners at respective stations as per Station wise Break up of material supply and as per technical s pecifications from approved vendors specified in tender document

-

-

-

... More
For fixed portion :

-

-

-

... More
Size of Tile 500x500 mm

28

48415

-

... More
6 mm cement plaster of mix 1:3 (1 cement : 3 fine sand)

365

109272

-

... More
Supplying, fabricating and fixing M.S. structural steel work made of joists, tubes, pipes, channels, angles, plates, flats, bars etc., for struts, chain link fencing posts as per drawing including gate, ladders, safety grills, walkways, collapsible gate, signboards, supports for cable trench, cable racks, cable tray support, chequered plates, push button control posts, supporting structures, making slots for barbed line, wire hoisting, placing in position, embedding in concrete, applying two coats of epoxy paint "EPILUX 155" High Build Enamel over a coat of EPILUX 610 Primer of M/s Berger or any other approved equivalent make as per manufacturer's recommendation, complete in all respect including cutting to required size welding of joints, fixing anchor plates,bolts, theading, nuts, washers, sleeves etc. and necessary lettering of approved pattern on main gate, signboards etc.complete in all respects inclusive of cost of all labour, materials, tools, tackles etc. as per drawings, specifications and directions of the Engineer-in-Charge. (excluding the cost of concrete work).

7

1042095

-

... More
Flareweld Access Fitting Assembly

1

25785

-

... More
"Supply & installation of Anode bed ( deep well type with MMO anodes) as per the approved configuration for Impressed Current Catho dic Protection system including supply, laying & termination of all anodes, anode tail cable (XLPE insulated copper conductor) suit able with length for connecting upto Anode junction box without any joints in between including laying of PVC sleeve / trunk pipe, casing pipe , centralizers, vent pipe & drawing all the lead wires through the pipe and connecting the same with Anode bus in Anode junction box including erection and providing foundation of Anode Junction Box as per specifications inlcuding supply, excavation , backfill of earth etc. as per specification & also compacting the same with soil for restoring it to normal finished ground level all complete with all labour & material as per instruction of Site Engineer / Engineer-in-Charge, Specifications and approved draw ings. Note : Each Anode bed means anode bed at each location irrespective of number of anode strings required."

-

-

-

... More
Fabrication of Mitre Bends - Long Radius ( fire water piping): Taking delivery of pipes from designated locations, transporting the same to site and fabrication of carbon steel piping specials by cutting, edge preparation, welding, all types of testing including r adiography & including supply of all inputs such as labour, materials (other than those specifically undertaken to be supplied by th e Owner under the contract), equipments, consumables etc. necessary to perform and completing the work in all respects in accordance with drawings, specifications and instructions of the Site Engineer / EIC.

-

-

-

... More
6", 150#/300#, F/F

1

8992

-

... More
4"x ANSI 150# HOV F/F API 600 Gate Valve

20

368868

-

... More
In all kinds of soil

222

53162

-

... More
1:2:4 [1 cement : 2 coarse sand derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sour ces]

16

153730

-

... More
Bib Cock (Ref. Make: JAQUAR, Model: Cat. No. 0037 or approved equivelent)

5

10065

-

... More
Providing and fixing 10 mm thick acid and/or alkali resistant tiles of approved make & colour using acid and/or alkali resisting mor tar bedding and filling joints with acid and/or alkali resisting cement as per IS:4457, all complete as per specifcations and direct ions of the Engineer-in-Charge :

-

-

-

... More
Providing and laying Polished Granite stone slab (Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent) flooring in required de sign and patterns, in linear as well as curvilinear portions of the building, all complete as per the architectural drawings, with 1 8 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand), laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade, including rubbing, curing and polishing etc. al l complete as specified and as directed by the Engineer-in-Charge.

107

496903

-

... More
4" Spectacle Blind 600# F/F

15

285058

-

... More
Supplying and providing non-shrinkable cement grout (SHRINKKOMP 20 or any other equivalent approved brand) for grouting holding down bolts in pocket holes for equipment foundation, including necessary surface preparation mixing of grout, curing as per manufacturer 's recommendation/ specification and directions of the Engineer-in-Charge. [Note: This item shall be operated under specific instruc tions of the Engineer-in-Charge]

2654

226047

-

... More
3", 150#/300#, F/F

2

9890

-

... More
1:4:8 [1 cement : 4 coarse sand (Zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from n atural sources]

121

922501

-

... More
1:6 (1 cement : 6 fine sand)

1076

414944

-

... More
3"x ANSI 600# F/F API 6D SCV

2

85457

-

... More
Thermo-Mechanically Treated bars of grade Fe-500 D or more

19723

2168591

-

... More
"FLP & WP JUNCTION BOX Supply, erection, installation, testing and commissioning of flameproof & weather proof junction box for providing cable terminatio n of motor, including connection and termination of earthing wire and conduits etc., including supply & installation of double compr ession cable glands & flame proof plugs for sealing all spare entries complete as per drawings, specifications and direction of the Site Engineer, including the cost of all labour, tools, consumable materials etc., complete in all respect: "

-

-

-

... More
Supplying & providing approved type of extruded polyethylene mesh (rock shield) on mainline pipe to protect the coating against rocky soil including supply of all inputs such as labour, materials, consumables etc. necessary to perform and complete the work in all respects in accordance with the specifications, manufacturer's recommendation and instructions of Site Engineer / Engineer-in-Charge. NOTE: 1. Proper lateral as well as transvers overlap shall be provided as per specifica tions/ manufacturers recommendation

-

-

-

... More
Routine Test (Test Load 1.5 times the Safe Capacity) [Note: Unit "EA" shall mean "PER TEST"]

1

26427

-

... More
2"X1" x Concentric Reducer X 300#

1

333

-

... More
UPTO 100 METERS (with OFC conduit)

-

-

-

... More
3" 300# Equal Tee-ASTM A420 Gr.WPL6

35

20237

-

... More
Providing and applying tack coat using bitumen emulsion conforming to IS:8887, using emulsion pressure distributer including prepari ng the surface & cleaning with mechanical broom :

-

-

-

... More
Type B (Flameproof & Weatherproof as per specifications & drawing) (With inbuilt provision of Voltmeter & pushbutton for PSP Measurm ent)

9

540908

-

... More
1:2:4 [1 cement : 2 coarse sand (Zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from n atural sources]

220

1966690

-

... More
"Exhaust fan / wall bracket fan wiring: Wiring with PVC insulated 2.5 sqmm copper conductor wire for phase & neutral , 650 V grade i ncluding earthing , the third pin with 1.5 sqmm copper conductor earthing insulated continuity wire for exhaust/ wall bracket fan in cluding providing and fixing of 5 pin 6 A modular socket and 10 A modular switch near the door or as as per specifications and drawi ngs. The circuit wiring shall be with 4 sq. mm PVC copper wire from switchboard to 1st exhaust fan for multiple exhaust fans in one circuit. "

36

87132

-

... More
Flameproof Type E (With Ingress Protection IP:55) as per specification

9

491868

-

... More
Bend- 87.5 Degrees (110 mm)

40

6839

-

... More
1:1.5:3 [1 cement : 1.5 coarse sand (Zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived fr om natural sources]

368

4731509

-

... More
10", 150#/300#, F/F

15

269783

-

... More
Supply and installation of MDF (Main distribution frame) /Distribution box of 50 Pair capacity as per specifications

1

6651

-

... More
450 mm dia R.C.C. pipes

37

113227

-

... More
Laying cased crossings, by auger boring & jacking method, using casing pipes and 3LPE coated carrier pipes, according to drawings, specification(s) and providing all works, labour, inputs and materials/ consumables necessary to perform and complete the works in all respect in accordance with the contract, including collecting the pipes and other Owner-supplied materials from Owner#s issue point and loading, transporting them to site, setting out the works, aligning and welding the casing and carrier pipes, 100% radiography of weld joints of carrier pipes, field joint coating, holiday detection & repair of coating, applying atleast 2(two) coats of bitumastic paint over coat of suitable primer over casing pipe and two component epoxy coating for internal surface of casing pipe, excavating/ trenching and/or boring in all kinds of soil, including rocky strata if any, inserting the casing pipe into the bore, pre-hydrostatic testing of the carrier pipe and replacement / rectification of defects / pipes, installation of approved type of insulators throughout the cased section on the carrier pipe, carefully inserting the carrier pipe inside casing pipe by jacking/ pushing method, taking care not to damage the insulators, sealing the ends of the casing pipe with approved heat shrinkable wraparound type end seal, fixing of vent pipes at the ends of the casing pipe, priming and applying two coats of coal-tar based epoxy paint on underground portion of vent pipes, measuring final resistance between carrier pipe and casing, and doing preparation work necessary to produce correct resistance, applying one coat of primer and two coats of epoxy paint to all exposed and overground fittings & piping, proper compaction of backfill below carrier pipe at either ends, independently supporting the carrier pipe outside each end of the casing pipe by suitable RCC supports with neoprene rubber sheet below the carrier pipe, and strengthening with sand bags and proper compaction of earth below pipe, to prevent differential settlement of carrier pipe and damage to insulators, final clean-up and restoration of the site and disposal of wastes and surplus in accordance with the contract and supply of all materials (other than those specifically undertaken to be supplied by the Owner under contract) necessary for or in the performance of the work or for temporary or permanent incorporation in the works, and all other acts, matters and things necessary to make the pipeline ready for commissioning in all respect, as per directions of Site Engineer/ Engineer-in-Charge. NOTE: 1. The work of cased crossing will include the provision of temporary supports for existing installations in the road and/or railroads, the provision of diversions, the restoration of the railroad/embankment to its original state, maintenance for subsidence and all other precaution(s), work(s) and/or maintenance expressed or implied in the contract. 2. The work will also include providing necessary independent support to carrier pipe outside each end of casing pipe by suitable RCC supports, proper compaction of backfill below carrier pipe at either ends and strengthening with sand bags and/ or other suitable means so as to prevent differential settlement of the casing pipe and damage to insulators, including all labour, materials etc. as per direction of Site Engineer/ Engineer-in-Charge. 3. All materials (other than the Owner-supplied materials) required for performance of the work shall be supplied by the Contractor at his own cost. 4. Casing end seal shall be of approved type only and shall be installed by skilled personnel as per approved procedure and demonstration by manufacturer's representative (to be arranged by mainline contractor). 5. Carrier pipe to be brought to the desired level of crossing by providing natural gradient to trench bottom from sufficient distance and avoiding field bends so as to keep provision for any future widening of Railway/ Highway etc,. 6. Casing insulators (made of HDPE) shall be interlocking type, free from metallic nuts & bolts.

-

-

-

... More
1:2:4 [1 cement : 2 coarse sand derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sour ces]

1

9608

-

... More
Supply of Flame Arrester: 4" flame arrester

2

447828

-

... More
Making Khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggr egate of 20 mm nominal size) over P.V.C. sheet 1 m x 1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse s and) and a coat of neat cement, rounding the edges and making and finishing the outlet complete.

20

6427

-

... More
Power cables LT : OD above 20 mm and upto 40 mm

7

47079

-

... More
6" 300# 90 deg LR Bend

25

79030

-

... More
Coupler (110 mm)

20

3102

-

... More
Supply of fully charged CO2 fire extinguishers as per specifications (4.5 kg capacity as per IS: 2878 latest)

13

94688

-

... More
FLP/ WP Junction Box, Type D including FLP/WP double compression type glands and plugs, as per tender specifications. (Bottom entries: 1 No. 1" NPT (suitable for 12CX1.5sqmm) Left side entries: 3 nos. ½" NPT (suitable for 4CX1.5sqmm) Right side entries: 3 nos. ½" NPT (suitable for 4CX1.5 sqmm)

13

59586

-

... More
Hollow Plug Assembly

1

19001

-

... More
8"x6" x Concentric Reducer x 600#

2

9749

-

... More
Providing & fixing Angle Valve (Ref. Make: JAQUAR, Model: Cat. No. 563 or approved equivalent) and Health Faucet with flexible tube 8mm diameter x 1.5 m long (Ref. Make: JAQUAR, Model: Cat. No. 549 or approved equivalent).

5

18470

-

... More
"PVC Conduit pipes Supply, installation, fixing in position, PVC conduit pipes, of ISI marked , in concrete, brick work etc. during or after construct ion by making grooves in the wall, ceiling etc. cutting threads and jointing the pipes with PVC couplers, providing necessary tees, bends, junction boxes etc. with 12 SWG GI wire inside conduit without joint for concealed wiring, including making good the concrete , brick work, surfaces etc. complete as per drawings and direction of Site Engineer / Engineer-in-charge including cost of all labou r, materials etc.: "

-

-

-

... More
Power cable 3 core x 2.5 mm2 Armoured, Copper as per tender specifications

1500

195266

-

... More
Preservation of entire pipeline / pipeline sections (including HDD sections) by using inhibited water with uniform inhibitor concentration adequate for 6 (six) months preservation period as per manufacturer's recommendation including arranging water, testing of water, supply of inhibitor, all equipment, manpower, consumables etc. complete as per specifications and direction of Site Engineer / Engineer-in-Charge.

-

-

-

... More
On steel work

6

1499

-

... More
32 mm nominal dia pipes

145

78991

-

... More
With material conforming to Grade-I (size range 75 mm to 0.075 mm) having CBR Value-30

138

457525

-

... More
1" BLRF 300#

4

1434

-

... More
Foundations, footings, bases for columns

388

145538

-

... More
4"x2" 600# Unequal Tee

20

37453

-

... More
REINFORCED CEMENT CONCRETE :

-

-

-

... More
Providing and applying 2.5 mm thick road marking strips (retro-reflective) of specified shade/ colour using hot thermoplastic materi al by fully/ semi automatic thermoplastic paint applicator machine fitted with profile shoe, glass beads dispenser, propane tank hea ter and profile shoe heater, driven by experienced operator on road surface including cost of material, labour, T&P, cleaning the ro ad surface of all dirt, seals, oil, grease and foreign material etc. complete as per directions of the Engineer-in-Charge and accord ance with applicable specifications.

54

43184

-

... More
6.625"

86

598732

-

... More
Installation, testing and commissioning of Pressure Indicator (PI) of various ratings as per drawings, recommendations of OEM and directions of Engineer in-charge/ Site engineer

7

34627

-

... More
15 mm cement plaster on the rough side of single or half brick wall of mix :

-

-

-

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :

-

-

-

... More
2"x ANSI 600# HOV F/F API 6D Ball

60

2463486

-

... More
"Copper Strips/ Flats for Jumpers for Flanged Joints of the Product Process Piping: Supply and Installation of one copper jumper per flanged joint across the flanged joints for valves, spool piece, branch offs etc., of product process piping, The job includes cutt ing drilling of holes of required size in the copper strips/ flats for bolting purpose and complete the works in all respects as per specifications & drawings and instructions of Site Engineer/ EIC. Note: Copper jumpers shall be installed in all the flanged joints of Product Process piping only and not in fire water lines. "

-

-

-

... More
3"x1" 600# Un Equal Tee

5

6094

-

... More
Felling trees of the girth (measured at a height of 1 m above ground level), including cutting of trunks and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material :

-

-

-

... More
In flooring on a bed of 10 mm thick mortar 1:4 (1 acid and/or alkali resistant cement : 4 coarse sand) :

1

1968

-

... More
Vertical load testing of piles in accordance with IS:2911 (Part-IV) including installation of loading platform by Kentledge/ Anchor piles method and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per sp ecification & the direction of the Engineer-In-Charge. [Notes : (1) Initial and Routine Load Test shall not be carried out by Dynami c method of testing. (2) Testing agency shall submitt the design of loading platform for the approval of the Engineer-in-Charge.] :

-

-

-

... More
2", 600#/900#, W/W

20

94966

-

... More
25 mm nominal dia pipes

63

46620

-

... More
Providing & fixing Angle Valve (Ref. Make: JAQUAR, Model: Cat. No. 563 or approved equivalent) and Health Faucet with flexible tube 8mm diameter x 1.5 m long (Ref. Make: JAQUAR, Model: Cat. No. 549 or approved equivalent).

3

11082

-

... More
LT DG set with PLC based AMF panel, fuel tank etc

5

274856

-

... More
Area of slab up to 0.50 sqm

37

205482

-

... More
Civil Stn Non ITC

-

-

-

... More
Constructing brick masonry Septic Tank with brickwork in cement mortar 1:6 including R.C.C. 1:2:4 (1 cement : 2 sand : 4 graded coar se aggregate) top slab, C.I. cover all as per standard drawing, etc. complete in all respects inclusive of cost of all materials, la bour, tools, tackles etc. as per drawings, specifications and directions of the Engineer-in-Charge :

-

-

-

... More
Foundations, footings, bases of columns, etc. for mass concrete

1653

620037

-

... More
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the Manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 ce ment : 4 coarse sand), jointing with grey cement slurry @ 3.3 Kg/sq.m. including grouting the joints with white cement and matching pigments etc., complete :

-

-

-

... More
Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cemen t: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and poli shing complete.

39

92958

-

... More
Installation of wall mounted Fibre Termination Box (FTB) as per tender specifications and directions of Engineer-in-charge/ Site Engineer

3

29039

-

... More
3" NB Pipe Joints RT

175

168091

-

... More
Taking delivery and transportation of bare pipes from owner's stockpile, transportation, unloading the pipes at manufacturer's works and fabrication of Long Radius (R=6D) Hot pulled induction bends having tangent length of approximately 1000m at both ends as per specification and delivery of hot pulled bends to site including visual examination, manual U.T. on the entire weld seam, bevelling of ends as per API 5L, supply of all materials, consumables, labour etc. as per specifications and direction of Site Engineer / Engineer-in-Charge.

-

-

-

... More
Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms :

-

-

-

... More
Providing and making Construction/ Contraction joint by mechanically cutting 12mm x 25mm deep groove and filling with bituminous sea ling compound including cleaning etc. complete as per drawing, specifications and directions of the Engineer-in-Charge.

502

355635

-

... More
2 NPS (2.375" OD x 0.218"/ 0.344" WT) ASTM A106/ A333/ A53 Pipe

160

229392

-

... More
8" NB Pipe Joints RT

50

95344

-

... More
Supervision Charges during erection, installation and commissioning of following electrical equipment on call basis including transp ort, boarding, lodging and other personal expenses-

-

-

-

... More
8" Spectacle Blind 600# F/F

1

41007

-

... More
Shoe - Plain (110 mm)

20

2996

-

... More
4" x 150#/300#/600#/900# Insulating Coupling

12

68930

-

... More
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level :

-

-

-

... More
Supplying and fixing Road Hump of minimum size 350 mm width x 50 mm thick made of Carbon Black mixed Rubber with Additive of LDPE fo r reinforcement & UV resistant colouring agent of black & yellow colour with 4 reflective glass beads, of weight not less than 16 Kg /metre, and capacity to withstand minimum 35 tonne weight (moving vehicle load) including cleaning the road surface of all dirt, sca les, oil, grease and foreign material etc. and fixing the hump on the Road top as per manufactures specifications with necessary fas teners complete in all respects inclusive of cost of all labour, materials, fasteners, tools, tackles etc. as per specification and directions of the Engineer-in-Charge.

30

100770

-

... More
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the Manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 ce ment : 4 coarse sand), jointing with grey cement slurry @ 3.3 Kg/sq.m. including grouting the joints with white cement and matching pigments etc., complete :

-

-

-

... More
Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dump ing ground within 50 metres lead.

10

513

-

... More
12.5 mm thick square edge PVC Laminated Gypsum Tile of size 595x595 mm, made of Gypsum plasterboard, manufactured from natural gypsu m as per IS:2095 (Part-1) and laminated with white 0.16 mm thick fire retardant PVC film on the face side and 12 micron metalized po lyester on the back side with all edges sealed with the face side PVC film which goes around and wraps the edges and is bonded to th e edges and the back side metalized polyester film so as to make the tile a completely sealed unit.

103

255120

-

... More
6.625"

100

25960

-

... More
2 kg clean agent extinguishers IS 15683 Marked

5

74576

-

... More
Polyester powder coated (Minimum thickness 50 micron) Aluminium

14

1639

-

... More
Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7 Kg per square metre on dam p proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil.

127

18395

-

... More
12" NB - Double Cut Joint

2

43518

-

... More
FLAMEPROOF TUBELIGHT, 2x22Watt, LED, SUITABLE FOR Exd Gas Group II C, as per IS/IEC 60079-2007

22

262645

-

... More
Universal Nozzle

2

13164

-

... More
1" F/F ANSI 600# A/G, BALL VALVE- BS 5351/ ISO 17292

8

133358

-

... More
Fasteners for Flanges 6" x 300# (0.750" Dia. X 6.25" Length) - extended stud length for flanges with spectacle blind

72

17650

-

... More
All works upto plinth level

10

105311

-

... More
Taking delivery, shifting within a road distance of 500 meters and installation & testing of the differnt instruments (like pressure Gauge, Pressure Switch, Pressure Transmitter, temperature transmitter, scrapper detector, level switch, level transmitter, flow switch etc.) of various ratings by fabrication and installing all the required pipe fittings with pressure pipes, valves, plugs, tees, nipples, junction box, cables, supply and erection of all other required materials such as the supporting structure, Clamps, cannopy, screws, nuts, bolts, aluminium sheets, GI wire, steel plats, cement concrete etc. complete in all respects including supply of suitable size non flame proof cable gland at control panel end and terminating the already laid cables at field, junction box and control panel end, mounting the junction boxes as per the Drawings, specifications and directions of the engineer in-charge/site engineer including cost of all labour, materials, consumables, tools, tackles and services rendered etc. All the instruments shall have to be properly connected to the earth pit through GI wires. The works shall include labelling, tagging using SS plates, glanding and ferruling at both field and panel side. Installation to be done as per OEMs recommendations, vendor drawings and other approved drawings. The scope also shall include Calibration of instruments, hydro-testing of Impulse tube, providing assistance in testing and commissioning of the instruments to control system vendor along with loop checking etc.

-

-

-

... More
40 mm nominal dia pipes

58

40994

-

... More
Installation of pre-fabricated RCC (1:1.5:3) Joint Box with lid as per tender specifications, drawings and directions of Engineer-in-charge/ Site Engineer

45

159440

-

... More
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishi ng and reinforcement - All work up to plinth level :

-

-

-

... More
Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cemen t: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and poli shing complete.

8

19068

-

... More
Decorative Light fittings: Supply, installation, connection, earthing and testing of the following fittings, including supply and in stallation of drop pipes, hooks, fittings, fixtures, nuts,bolts, supports, on walls, outlet box for regulators and all other require d materials etc. as per specifications, drawings and directions of the Site Engineer including cost of all labour, tools, materials etc. complete in all respects.Make of the fittings can be the make mentioned in the respective SOR items or equivalent model from th e approved make list given in the specifications:

-

-

-

... More
3", 300#/900#, F/F

2

9890

-

... More
Providing and fixing Unplasticised PVC (uPVC) pipe clips (110 mm) of approved design to unplasticised-PVC rainwater pipes by means o f 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.

80

30424

-

... More
Up to 30 mm wide x 1 mm thick Copper strip

100

27140

-

... More
4 NPS 4.5" OD x 0.237"/0.337" WT ASTM A106/ A333/ A53 Pipe

125

452825

-

... More
Demolishing brick work in cement mortar manually or by mechanical means including stacking of serviceable material and disposal of u nserviceable material within 50 metres lead as per the directions of Engineer-in-Charge. [Notes: (1) Dismantling shall be allowed du ring day shift only & prior permission for the same shall be obtained. (2) Providing of necessary covers/ barricades around the work area shall be done prior to dismantling operations]

1

1935

-

... More
RAINWATER HARVESTING & TUBEWELLS :

-

-

-

... More
Electrical Siren

1

42874

-

... More
6.625" OD

30

370284

-

... More
2"x ANSI 300# F/F API 6D SCV

2

31260

-

... More
3", 300#/900#, F/F

4

23939

-

... More
Modular Cable Transit (MCT): Supply fixing and erection of modular cable transit (MCT) for cable entry to building in proper frame i ncluding supply of peelable type, spare block, stay plates compression wedgs etc. with all accessories as per specification consider ing 20 % minimum spare in each module to be installed as per instruction of Engineer in charge/ site engineer:

-

-

-

... More
DRAINAGE :

-

-

-

... More
DISMANTLING & DEMOLISHING :

-

-

-

... More
Laying of HDPE conduit and blowing of OFC cable inside the SV/MOV premises along the boundary wall, line item includes supply & installation of suitable clamps , connectors, fixture, corner bends, tools & tackles (comprising of anchor bolts/nuts/accessories etc) required for OFC entry inside SV/MOV loctaionalong the boundary wall by clamping of HDPE conduit at a height of 1 meter above the finished ground level and extending it along the length of boundary wall at 1 meter height upto the transition pit inside SV/RCP building as per attached drawing no. STD-793-00. The line item includes all sevices required for blowing of OFC cable iin HDPE conduit inside the MOV/SV loctaion as per STD - 793 drawing.

1200

55308

-

... More
Beyond 30 cm girth upto and including 60 cm girth

12

6014

-

... More
CLADDING WORK :

-

-

-

... More
New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)

222

48148

-

... More
Supply and erection of Medium Velocity Water Sprinkler System: Analysis of adequacy of existing MVWSS system for new facilities. Design and extension of Medium Velocity Water Sprinkler System for new facilities consisting of Barrel area, metering and piping area etc for Jalandhar Station

1

686379

-

... More
Carrying out tieing-in and hook-up of mainline pipe with the HDD sections of pipeline (executed by other agency) (Optional) on either side of the HDD pipe section , including excavation/ trenching in all kinds of soil including rock, cutting of pipe, making field bends out of pre-tested pipes to match the site requirement, welding, carrying out 100% radiography, field joint coating, holiday detection, repair of damaged coating, backfilling and making through the pipeline etc. complete in all respects. Note: This item shall be operated under specific instructions of Engineer-in-Charge.

-

-

-

... More
450 mm Finished Floor Height (FFH)

1

7063

-

... More
Constructing brick masonry chamber for underground C.I. inspection chamber and bends with common burnt clay F.P.S. (Non-modular) bri cks of class designation 7.5 in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 Kg and weight of frame 15 Kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cemen t : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design :

-

-

-

... More
12"x10" x Concentric Reducer x 150#

1

5607

-

... More
In flooring on a bed of 10 mm thick mortar 1:4 (1 acid and/or alkali resistant cement : 4 coarse sand) :

73

143713

-

... More
8" x 150# 45° LR Bends

4

8783

-

... More
750mm x 750mm x depth up to 1000mm inner dimensions

7

141516

-

... More
Centrifugally cast (spun) iron socket & spigot (S&S) pipe as per IS:3989

27

38832

-

... More
SANITARY INSTALLATIONS :

-

-

-

... More
"Cathodic Protection Units : Erection, testing and commissioning of cathodic protection units (CPTR/CPPSM); including supply and installation of all facilities, materials etc., including fuses, all supporting structures, laying and connecting the 1100 V Grade power cable (2 runs of 1Cx25 sqmm Cu. conductor XLPE insulated Armoured Cable) from DCDB to CPPSM unit / laying and connecting the 1100 V Grade power cable (owner pr ovided 1 run of 3Cx10 sqmm Al. conductor XLPE insulated Armoured Cable) from ACDB to CPTR unit or both as required, providing earth ing arrangement. The work includes furnishing the test results by conducting all the NO LOAD and ON LOAD tests on the CP units and a djusting settings as required and testing the pipeline section for full cathodic protection for entire stretch. The job complete in all respect shall include cost of all labour, tools as per specifications and directions of the Site Engineer / Engineer-in-Charge. "

-

-

-

... More
Silent LT DG set: Erection, Installation including transportation from owner desginated location, connecting, testing and commissio ning of owner supplied Emergency LT DG set including execution of terminal connection of power/control cable. The work shall include grounding of alternator neutral, earthing, providing water pipe connection for Radiator water make-up complete with valve, solenoid valve etc. piping for fuel line, fabrication, welding, erection and painting of owner supplied support structure (including supply of shortfall support structure, if any) for exhaust piping, mounting on channels/AVM pads, installation of PLC based AMF panel, NIG panel, exhaust piping including insulation and cladding, fuel piping etc., materials, labour, tools and tackles, consumables etc , a s per drawings, specification and directions of Site Engineer / Engineer-in-Charge:

-

-

-

... More
Supply of OFC Jointing kits suitable for 48F OFC cable as per tender specifications.

33

349489

-

... More
6 mm cement plaster 1:3 (1 cement : 3 fine sand) finished with a floating coat of neat cement and thick coat of Lime wash on top of walls when dry for bearing of R.C.C. slabs and beams.

16

6355

-

... More
Coupler (110 mm)

11

1706

-

... More
"EARTH STRIP / WIRE / ROPE / CABLE: Supply, installing and testing of earthing strip/wire/rope/cable for completely making the ear thing grid system by supplying, laying the GI / Cu strip and making all the necessary welding joints, connecting to the earthing electrodes and existing earthing grid etc., complete as per drawings, specifications and directions of the Site engineer/Enginee r-in-charge, including the cost of all labour, tools, materials, etc. complete in all respect: "

-

-

-

... More
Supply and erection of Medium Velocity Water Sprinkler System: Medium Velocity Water Sprinkler System for Station consisting of Barrel area, filteration, metering and piping area etc for Goindwal Sahib Station

1

2745517

-

... More
6.625" OD

30

321078

-

... More
Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per directions of the Engineer-in-Charge.

1

1746

-

... More
Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using coarse aggregate as well as fine aggregate derived from natural sources and cement content as per approved design mix, manufactured in fully automatic batch ing plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site of laying , ex cluding the cost of centering, shuttering finishing and reinforcement, including cost of admixtures in recommended proportions as pe r IS:9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per directions of the Engineer-in-Charge. [Note : Cement content considered in this item is @ 330 kg/cum. Excess/ less cement used as per design m ix is payable/ recoverable separately] :

-

-

-

... More
With medium setting bitumen emulsion :

-

-

-

... More
1:3:6 [1 cement : 3 coarse sand (Zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from n atural sources]

5

52838

-

... More
3"x2" x Concentric Reducerx 600#

1

1065

-

... More
4" WNRF 300#

6

13069

-

... More
35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws

10

24844

-

... More
Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per the directions of Engineer-in-Charge. [Notes: (1) Dismantling shall be allowed during day shift only & prior permission for the same shall be obtained. (2) Providing of necessary covers/ barricades around the work area shall be done prior to dismantling operations. (3) Cutting of all reinforcement shall be done using hack saw or chiesel or any other method as approved by the Engineer-in-Charge]

1

3337

-

... More
6", 600#/900#, F/F

4

39567

-

... More
With medium setting bitumen emulsion :

-

-

-

... More
"Supply & installation of Anode bed ( shallow type ) as per the approved configuration for 'Impressed Current Cathodic Protection' system including supply, laying & termination of all anodes, anode tail cable (XLPE insulated copper conductor) suitable with length for connecting upto Anode junction box without any joints in between including laying of PVC sleeve / trunk pipe & drawing all th e lead wires through the pipe and connecting the same with Anode bus in Anode junction box including erection, providing foundations of Anode Junction Box, chain link fencing around anode junction box wherever required, as per specifications including supply of b ack fill material, excavation, backfill of earth and filling the sand with requisite back fill material as per specification & also compacting the same with soil for restoring it to normal finished ground level all complete with all labour and material as per ins truction of Site Engineer / Engineer-in-Charge, Specifications and approved drawings. Note : Each Anode bed means anode bed at each location irrespective of number of anode strings required."

-

-

-

... More
2" NB Piping

1

2736

-

... More
Providing and fixing the following washroom fittings, complete in all respects; inclusive of cost of all materials, labour, tools, t ackles etc. as per specifications and directions of the Engineer-in-Charge :

-

-

-

... More
15 mm nominal dia pipes

10

5394

-

... More
Supply and Installation of CS corrosion coupon with 1 sq. cm bare metal with 2 numbers 4 sq. mm lead of minimum 10 m long lead in a sdistance of 0.5 m from the pipeline inclusive of cable & terminating the cable in the TLP terminal. The corrosion couponf are to be installed with specified test lead points for which prior apporval to be obtained from owner. The item also incluseds supply, ins tallation, laying & termination of all CU cables of required length (as per site condition) and size as mentioned in the standard dr awing, toggle switch, cable glands and lugs etc. , complete in all respect as per the direction and specification detailed in the do cumetn complete with all tools , takles & other necessary requirement for preparation of the coupon . The work complete in all respe ct shall include supply of all the labours, tols etc. compete as per the direction of site engineer/engineer in charge.

39

273445

-

... More
3"x1" x Concentric Reducerx 600#

1

1156

-

... More
Under ground piping for Fuel / Air piping: 1.315" ODx 0.179" WT ASTM A 106 / A53/ API 5LGr B Pipe: Taking delivery of pipes, pipe f ittings, steel flanges, spiral wound metallic gaskets & fasteners from designated location within station premises transporting the same to site, fabrication and erection of underground piping including cutting, edge preparation, bending, threading, lining up and welding, excavating, trenching in all kind of soil to specific depths as indicated in drawings and installing pipes and all types of pipe fittings like flanges, elbows, equal and reducing outlet tees, concentric/eccentric reducers, drain funnels, vent pipe and tap ping for instrument such as pessure gauges, thermal relief valves, thermowells etc., underground at elevations indicated in the draw ing connecting with equipment nozzles, valves, vessels, in-line instruments etc., cleaning the material surface by sandblast cleanin g, coating and wrapping the pipes/pipe fittings with coaltar base tape coating material (including the supply of coating tape, preco at material etc.), holiday detection of the coating, cleaning of coated pipes by water flushing after cleaning by compresed air prio r to installation of valve, cleaning by card board/ Tin blasting method, hydrostatic testing of each section to the specified pressu re, draining the water, tie-in, back filling, restoration of site final cleaning up and disposal of water and surpluses, providing a ll inputs such as labour, materials equipment and consumable necessary to perform the work (other than those specifically undertaken to be supplied by the owner under the contract) and completing the work in all respects in accordance with the drawings, specifica tions and instructions of the Site Engineer / EIC

15

40108

-

... More
6.625" in Normal Soil

790

10813520

-

... More
Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrange ments for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27. 5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS:4454 (Part-1) and M.S. top co ver of required thickness for rolling shutters :

-

-

-

... More
Providing and applying tack coat using bitumen emulsion conforming to IS:8887, using emulsion pressure distributer including prepari ng the surface & cleaning with mechanical broom :

-

-

-

... More
Supplying & fixing welded steel wire fabric of rectangular mesh 75 x 25 mm size, weight not less than 7.75 Kg/sqm fixed on angle iro n frame by welding, painted with two coats of synthetic enamel paint of over a coat of red oxide zinc chrome primer complete in all respects inclusive of cost of all labour, materials, tools, tackles etc. as per drawings, specifications and directions of the Engin eer-in-Charge. [Note: This item is for openings in DG, Compresoor, Transformer/ VCB Room/ AVR Room. Angle iron frame shall be paid s eparately].

113

197805

-

... More
Galvanised mild steel frame with packing space of Min.120x240 mm with multi diameter blocks and accessories with peeling off arrange ment to adjust cable size from 3.5mm to 99mm outer dia.

36

870269

-

... More
230V AC cum 48 V DC Operated automatic type Cathodic Protection Power Supply Module (CPTR cum CPPSM) unit of rating 25 V, 25 A DC wi th with DC-DC converter & SCADA linkage facility as per specifications

2

108381

-

... More
Making plinth protection 50 mm thick of cement concrete 1:3:6 [1 cement : 3 coarse sand derived from natural sources : 6 graded ston e aggregate 20 mm nominal size derived from natural sources] over 75 mm thick bed of dry brick ballast 40 mm nominal size, well ramm ed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth, etc . complete in all respects inclusive of cost of all labour, materials, tools, tackles etc. as per drawings, specifications and direc tions of the Engineer-in-Charge.

73

59027

-

... More
Area of slab up to 0.50 sqm

26

144392

-

... More
3" WNRF 600#

10

14242

-

... More
Providing and fixing rectangular high density polyethylene water storage loft tank with cover (Ref. Make: SINTEX or approved equival ent), conforming to ISI:12701, colour of opaque white or as approved by the Engineer-in-Charge. The rate includes making necessary h oles for inlet, outlet & overflow pipes. The base support including fittings & fixtures for tank shall be paid separately.

10

115

-

... More
Dry Chemical Powder silliconised potassiun bicarbonate type IS marked, pack in 10Kg

20

8142

-

... More
STEEL WORK :

-

-

-

... More
Supply and delivery of pipe fittings at respective stations as per Station wise Break up of material supply and as per technical sp ecifications from approved vendors specified in tender document

-

-

-

... More
Supplying, fabricating and fixing M.S. structural steel work made of joists, tubes, pipes, channels, angles, plates, flats, bars etc., for struts, chain link fencing posts as per drawing including gate, ladders, safety grills, walkways, collapsible gate, signboards, supports for cable trench, cable racks, cable tray support, chequered plates, push button control posts, supporting structures, making slots for barbed line, wire hoisting, placing in position, embedding in concrete, applying two coats of epoxy paint "EPILUX 155" High Build Enamel over a coat of EPILUX 610 Primer of M/s Berger or any other approved equivalent make as per manufacturer's recommendation, complete in all respect including cutting to required size welding of joints, fixing anchor plates,bolts, theading, nuts, washers, sleeves etc. and necessary lettering of approved pattern on main gate, signboards etc.complete in all respects inclusive of cost of all labour, materials, tools, tackles etc. as per drawings, specifications and directions of the Engineer-in-Charge. (excluding the cost of concrete work).

8

1190966

-

... More
FROM 1001 METER TO 1250 METER (with OFC conduit)

-

-

-

... More
25 kg DCP Extinguisher

2

34968

-

... More
Supply, installation, testing and commissioning of two separate 4-20 mA converters(0-20 mV Input, 0 to-2VDC input respectively, 2x 4-20 mA Output in each converter) in pre installed TLPs at SV/IPIG/CP locations as per the approved drawings and specification deta iled in the document complete with tools, tackles & other necessary requirement. The work complete in all respects including all mat erials, tools, tackles, labour as per tender specifications, AFC drawings & directions of the Site Engineer/Engineer-In-Charge.

4

42125

-

... More
With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel work (second coat).

5

179

-

... More
Corrosion monitoring probes: Installation of corrosion monitoring probes including 2" Flareweld on station piping at desired locatio n and 12 O'Clock position for mounting of ER Probe under the supervision of site engineer. Flareweld assembly shall be supplied by o wner. The job complete in all respect with material, tools & tackles, consumables etc.

1

18909

-

... More
CONCRETE WORK :

-

-

-

... More
Supply of Cathodic Protection unit of approved make, complete in all respects as given in the specification with all its accessories to ensure trouble free operation

-

-

-

... More
Casting, supplying and erecting in position precast reinforced cement concrete elements (with proper lifting lugs) for trench & drai n covers, shelves, partitions, post, slabs etc. for all leads and levels including making necessary moulds, vibrating, tamping, cur ing, finishing the top surface with cement mortar 1:3 (1 cement : 3 fine sand) to give a smooth and even surface, transportation to Site, aligning and fixing in position with cement mortar 1:3 (1 cement: 3 find sand,) including making recess in brick wall for pla cing the precast element in position and making good the same etc. complete in all respects inclusive of cost of all labour, materia ls, tools, tackles etc. as per drawings, specifications and directions of the Engineer-in-Charge. [Note: Payment for Reinforcement s hall be made as per relevant item of SOR.] :

-

-

-

... More
ROOFING & CEILING :

-

-

-

... More
Providing and laying Neelgiri/ Mexican grass turf with earth 50mm to 60mm thickness of existing ground prepared with proper level an d ramming with tools wooden (Dhurmos) and than rolling the surface with light roller make the surface smoothen and light waterning w ith sprinkler and maintenance for 30 days or more till the grass establish properly, complete as per direction of the Engineer-in-Ch arge.

10

3255

-

... More
Construction of granular sub-base by providing close graded material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thicknes s with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per s pecifications and directions of the Engineer-in-Charge :

-

-

-

... More
Installation of OFC jointing kits as per drawings, specifications and directions of Engineer-in-charge/ Site Engineer

33

452930

-

... More
Lintels, beams, plinth beams, girders, bressumers and cantilevers

625

454344

-

... More
Supplying & fixing welded steel wire fabric of rectangular mesh 75 x 25 mm size, weight not less than 7.75 Kg/sqm fixed on angle iro n frame by welding, painted with two coats of synthetic enamel paint of over a coat of red oxide zinc chrome primer complete in all respects inclusive of cost of all labour, materials, tools, tackles etc. as per drawings, specifications and directions of the Engin eer-in-Charge. [Note: This item is for openings in DG, Compresoor, Transformer/ VCB Room/ AVR Room. Angle iron frame shall be paid s eparately].

480

840237

-

... More
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :

-

-

-

... More
ROAD WORK :

-

-

-

... More
FLP/WP EXHAUST FANS:

-

-

-

... More
Initial Test (Test Load 2.5 times the Safe Capacity) [Note: Unit "EA" shall mean "PER TEST"]

1

70474

-

... More
"PLASTIC INSCRIPTION PLATE: Supply and installation of approved quality plastic name inscription plates including engraving the inscriptions, providing screws, etc. for equipments viz. motors, motor control centres, switchgears, push button stations etc. as required, providing necessary hol es tapping etc. and fixing the same complete in all respect as per the direction of Site Engineer/Engineer-in-charge including the c ost of all labour, tools etc."

40

38017

-

... More
Supply of wall mounted DC distribution board of approved make in IP-42 ingress protection for power supply to CP equipments as given in technical specifications

-

-

-

... More
3"x2" 600# Unequal Tee

5

7528

-

... More
Providing and fixing Stainless Steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, b uffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts comple te, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of require d size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of the Engineer-in-Charge. [Note : For payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, f asteners etc.]

955

723661

-

... More
Size of Tile 500x500 mm

279

465783

-

... More
Fasteners for Flanges 2" x 300# (0.625" Dia. X 4.00" Length)

160

13782

-

... More
1:1.5:3 [1 cement : 1.5 coarse sand (Zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived fr om natural sources]

229

2327485

-

... More
Size of Tile 500x500 mm

12

20749

-

... More
1:4:8 [1 cement : 4 coarse sand (Zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from n atural sources]

25

190599

-

... More
80 x 1.25 mm M.S. laths with 1.25 mm thick top cover

70

271383

-

... More
6", 600#/900#, F/F

25

296740

-

... More
"Weight of unit above 500 kg but upto and including 1000 kg "

1400

122479

-

... More
Wind socks

2

8276

-

... More
4 way junction box with 4 cable entries (4 x 3/4") at bottom & 20 nos. terminals.

37

349236

-

... More
3"x ANSI 300# HOV F/F API 6D Ball

5

201570

-

... More
3" 600# 90 deg LR Bend

10

15989

-

... More
Providing and fixing carbon steel galvanised (minimum coating 5 micron) dash fastener of 10 mm dia. double threaded 6.8 Grade (Yield Strength 480 N/sq.mm.), counter sunk head, comprising of 10 m dia. Polyamide PA 6 Grade sleeve, including drilling of hole in frame , concrete/ masonry, etc. as per the directions of Engineer-in-Charge :

-

-

-

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :

-

-

-

... More
EARTHWORK :

-

-

-

... More
2" WNRF 300#

20

14230

-

... More
Finishing walls with textured exterior paint of required shade :

-

-

-

... More
MASONRY WORK :

-

-

-

2000

253865

-

... More
Test Lead Point : Supply, installation, testing & commissioning of Test Lead Point (TLP) fabricated MS Sheet with hinged front door , Heavy Guage MS pipe 100 mm nominal diameter, Phenolic laminated terminal plate, brass terminal bolts, neoprene gasket for front do or, vandal proof concealed lock, etc as per latest revision of Standard AFC drawing (9200-99900-404-603-00 : STD-483). The work inc ludes providing requisite concrete foundation of 600 mm x 600 mm x 800 mm at site, including MS hard pipe for cable entry through f oundation, erection of the TLP over concrete foundation, termination of cables to the brass terminal bolts inside TLP box, jointing the cables to pipe (using cad welding/ pin brazing technique), repairing the damage to coat & wrap (with coating repair etc.), back filling the trenches, cleaning the site, applying epoxy paint / powder coating etc. The work also includes supply, installation, l aying & termination of all XLPE, Cu cables of required length (as per site conditions) and size, lugs etc. The work includes supply and fixing of a non-corrosive name plate containing the details like KM location, identification, TLP No., direction of flow, connec tion scheme, type etc., on the side of the TLP box, etc. The name plate shall also include the details of corrosion coupon wherever installed, all as per the direction and specification detailed in the document complete with tools, tackles & other necessary requir ement. The work complete in all respects including all materials, tools, tackles, labour as per tender specifications, AFC drawings & directions of the Site Engineer/Engineer-In-Charge.

-

-

-

... More
Providing and fixing brass 100mm mortice latch and lock with 6 levers without pair of handles (best make of approved quality) for al uminium doors including necessary cutting and making good etc. complete.

12

7245

-

... More
INSTALLATION OF PI+PS/PT: Installation, assistance in testing and commissioning of Pressure gauges and Pressure switches (PI+PS) / p ressure Gauge and pressure transmitter (PI+PT) of various ratings as per the directions of Engineer-in-charge/ Site engineer and dra wings

7

71852

-

... More
Fasteners for Flanges 10" x 150# (0.875" Dia. X 5.25" Length)

1440

232790

-

... More
DISMANTLING & DEMOLISHING :

-

-

-

... More
Providing and fixing, on fixed glazing/ doors/ window panes, sun control film "HP NATURAL 35 SAFETY COMBINATION FILM-4Mil" of M/s. G ARWARE or approved equivalent make and shade, all complete as per manufacturer's specification and as per directions of the Engineer -in-Charge.

75

99024

-

... More
10" BLRF 150#

2

8901

-

... More
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS:733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neopre ne gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural d rawings and the directions of the Engineer-in-Charge. [Note: Glazing, paneling and dash fasteners to be paid for separately] :

-

-

-

... More
2" NB - Double Cut Joint

1

3779

-

... More
80 mm nominal dia pipes

144

372773

-

... More
Fire Proximity suit

1

6309

-

... More
Rough dressing the trenched ground including breaking clods.

50

99

-

... More
RUBBER HAND GLOVES : Rubber hand gloves suitable for 11/6.6 kV operation with ISI mark.

9

32251

-

... More
Providing and installing RCC (1:1.5:3) boundary pillars as per drawings on both edges of the ROW at 250 metres interval and at every turning point and/or as directed, including supply of all materials necessary for the fabrication of the pillars, casting and inscr ibing the pillars, excavation of earth, fixing the pillars & backfilling, applying two coats of oil paint over one coat of cement ba sed primer on exposed surface and work, labour, inputs & materials/ consumables necessary to perform and complete the work in all re spect under the contract and as per directions of Site Engineer.

690

1359714

-

... More
With material conforming to Grade-I (size range 75 mm to 0.075 mm) having CBR Value-30

98

324909

-

... More
Supply and installation of flood markers as per tender specifications, drawings and direction of Site-Engineer/ Engineer-in-Charge.

12

128544

-

... More
Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulde rs, in required thickness, for all leads & lifts, all complete as per directions of the Engineer-in-Charge.

1

1746

-

... More
With cement concrete 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 10 mm nominal size).

12

250794

-

... More
Retriever kit

1

1219928

-

... More
PILE WORK :

-

-

-

... More
Shoe - Plain (110 mm)

11

1648

-

... More
Type V Distribution Board: Double Door, EURO DB of Havells or equivalent approved make having 200 A TPN Bus Bar, 1 x 100 A FP MCB, 1 x100 A FP RCCB (100 mA Sensitivity), 9x32 A SPN Motor duty MCB as per specification.

2

167134

-

... More
New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)

828

179579

-

... More
Supply of ASTM A106 Gr.B pipes at respective stations as per Station wise Break up of material supply and as per technical specific ations from approved vendors specified in tender document

-

-

-

... More
Cement mortar 1:3 (1 cement : 3 coarse sand)

17

287876

-

... More
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above pl inth level :

-

-

-

... More
6.625" in Normal Soil

10

166380

-

... More
Beyond 60 cm girth upto and including 120 cm girth

12

26774

-

... More
Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per the directions of Engineer-in-Charge. [Notes: (1) Dismantling shall be allowed during day shift only & prior permission for the same shall be obtained. (2) Providing of necessary covers/ barricades around the work area shall be done prior to dismantling operations. (3) Cutting of all reinforcement shall be done using hack saw or chiesel or any other method as approved by the Engineer-in-Charge]

4

13351

-

... More
Providing and laying design mix reinforced cement concrete of M-30 grade in roads/ taxi tracks/ runways, using cement content as per design mix, using coarse sand and graded stone aggregate of 40 mm nominal size in appropriate proportions as per approved & specifi ed design criteria, providing dowel bars with sleeve/ tie bars wherever required, laying at site, spreading, levelling to required s lope/ camber and compacting mechanically by using screed board vibrators, vaccum dewatering process and finally finishing in require d texture by floating & brooming with wire brush, including steel form work with sturdy M.S. channel sections, curing, making provis ion for contraction/ expansion, construction & longitudinal joints (10 mm wide x 50 mm deep) by groove cutting machine, providing ex pansion joints as per drawing including dowel cap, sponge, sealing tape, bitumen painting, debonding tape and filling joints with ap proved joint filler and sealants, complete all as per direction of the Engineer-in-Charge. [Notes: (1) Item of joint fillers, sealan ts, dowel bars with sleeve/ tie bars to be paid separately. (2) The item rate is inclusive of cost of dowel cap, sponge, sealing tap e, bitumen painting, debonding tape. (3) Cement content considered in M-30 is @ 340 kg/cum. Excess/ less cement used as per design m ix is payable/ recoverable separately].

-

-

-

... More
W.C. pan with ISI marked white solid plastic seat and lid

5

44015

-

... More
Providing and fixing soil, waste and vent pipes :

-

-

-

... More
"Hook-up of New Piping with existing process Piping: Isolating the section by closing the valve and providing positive isolation wi th the help of suitable plates / spectacle blind, Draing of the section, water flushing,Cutting of portion of existing piping of req uired length by Cold cutting machine (to be arraged by contractor)/ Opening of WNRF/SORF/Blind Flange trimming, grinding, beveling the edges, adding spool piece of required length/ Tee of the corresponding pipe size, thickness, adjoining and welding both the pipe ends ,or welding WNRF to pipe and bolting it with spool pipe mating flange including supply of all inputs such as labour, material s, equipment, consumables etc. necessary to perform and complete the work in all respect as per specification and instruction of the Site Engineer / EIC. NOTE: i) This is a high precision work which is to be executing in minimum time so reduce operation downtime period taking all safety prec autions. Before start of work firm planning to be done in consultaion with EIC/ Site Engineer and contractor should mobile all requi red resources before start of work. ii) The job also include evacuation of product from the piping section after isolating the section and flushing with water and its d isposal. iii) Prior to start of work Party to prepare the complete scheme of hook up job and submit it to EIC/Site Engineer for approval and should carry out the job as per approved procedure."

-

-

-

... More
SAND FILLING: Supplying and spreading of approved quality fine dry river sand in cable trenches including the cost of all material, transport, load and lift charges, labour, tools and tackles, consumables etc , as per drawings, specification and directions of S ite Engineer / Engineer-in-Charge.

930

908241

-

... More
Fasteners for Flanges 4" x 300# (0.75" Dia. X 5.00" Length )

48

6060

-

... More
Making plinth protection 50 mm thick of cement concrete 1:3:6 [1 cement : 3 coarse sand derived from natural sources : 6 graded ston e aggregate 20 mm nominal size derived from natural sources] over 75 mm thick bed of dry brick ballast 40 mm nominal size, well ramm ed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth, etc . complete in all respects inclusive of cost of all labour, materials, tools, tackles etc. as per drawings, specifications and direc tions of the Engineer-in-Charge.

200

161719

-

... More
Direct Current Voltage Gradient Survey

85

491682

-

... More
Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to IS:15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of c ement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 Kg/sq.m. including grouting the joint with white cement & matching pigments etc. complete :

-

-

-

... More
Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per the directions of Engineer-in-Charge. [Notes: (1) Dismantling shall be allowed during day shift only & prior permission for the same shall be obta ined. (2) Providing of necessary covers/ barricades around the work area shall be done prior to dismantling operations] :

-

-

-

... More
Pipe size 8 inch NB to 28 inch NB

2

1241

-

... More
3"x ANSI 300# F/F API 6D SCV

2

46890

-

... More
Internal Work - Concealed in wall: Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for ho t & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This i ncludes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same inclu ding testing of joints complete as per directions of the Engineer-in-Charge :

-

-

-

... More
Civil Stn ITC

-

-

-

... More
6", 150#/300#, F/F

15

161866

-

... More
In all kinds of soil

1191

285207

-

... More
All works above plinth level upto floor V level

1

12379

-

... More
40 mm X 5 mm G.I. earthing strip

2000

468766

-

... More
10" ANSI 150# Equal Tee

5

45441

-

... More
Boring, providing and installation bored cast-in-situ reinforced cement concrete piles of grade M-25 of specified diameter and lengt h below the pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the le ngth of the pile to be embedded in the pile cap etc. by percussion drilling using Direct mud circulation (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, including removal of excavated earth with all its lifts and leads [No tes: (1) Length of pile for payment shall be measured up to bottom of pile cap. (2) Truck Mounted rotary/ TMR/ Tubewell boring machi ne shall not be used] :

-

-

-

... More
GI wire / rope 35 sq. mm

10

1628

-

... More
2"x ANSI 300# HOV F/F API 6D Ball

8

273391

-

... More
10" SWMG ANSI 150#

120

56498

-

... More
Cement mortar 1:6 (1 cement : 6 coarse sand)

34

275684

-

... More
Power cables LT : OD upto 20 mm

16300

667419

-

... More
Grading roof for water proofing treatment with :

-

-

-

... More
Lateral load testing of single pile in accordance with IS Code of practice IS:2911 (Part-IV) for determining safe allowable lateral load on pile :

-

-

-

... More
20 Pair Armoured PIJF Underground Telephone Cable as per specifications

200

38991

-

... More
Installation of pre-fabricated printed KM markers for OFC & HDPE as per tender specifications, drawings and directions of Engineer-in-charge/ Site Engineer

100

151432

-

... More
750mm x 750mm x depth up to 1000mm inner dimensions

13

262816

-

... More
Providing and fixing 15mm diameter C.P. brass angle valve as per following with C.P. copper connecting pipe 375mm long or as require d including nuts, washers, C.P. brass flange, etc. including cutting & making good the walls wherever required, etc. complete in all respects inclusive of cost of all materials, labour, tools, tackles etc. as per specifications and directions of the Engineer-in-Ch arge :

-

-

-

... More
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in d epth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5m.

45

13015

-

... More
Copper Cable size 1cx35 sq. mm Armoured

1200

554364

-

... More
Supplying and laying flat brick soling in foundation trench, in floors, garages, sumps, etc., with bricks of class designation 50 la id to proper slope, level and grade etc. filling of the joints with sand etc. complete in all respects inclusive of cost of all labo ur, materials, tools, tackles etc. as per drawings, specifications and directions of the Engineer-in-Charge.

1449

1189025

-

... More
Receiver with Safety Barrier & 3 digit LED display suitable for interfacing with SCADA as per specification.

1

328529

-

... More
2"x ANSI 600# F/F BS-1873 GLOBE Valve

16

491559

-

... More
Nominal concrete 1:3:6 or richer mix (including equivalent design mix)

4

9151

-

... More
Laying of HDPE Pipe in trenches/ walls/ concrete structure/ panels etc. as per specifications & drawings & blowing/ laying of Owner supplied Aurmoured/Unarmoured Optical Fibre Cable in HDPE pipe,jointing & splicing of OFC, carrying out end to end testing of laid Optical fibre cables by taking OTDR traces and submitting the OTDR trace printouts to Site Engineer/ Engineer-in-charge. The job includes the supply and installation of required materials such as fixing clamps, screws, tags etc. as required to complete the job in all respects as per drawings and directions of Site Engineer/ Engineer-in-charge including cost of all labour, tools & tackles, test instruments, materials etc. The job includes handing over the tested cables to the Telecom Works Contractor and providing necessary assistance/ support to the Telecom Works Contractor in commissioning of Local Area Network.

600

157204

-

... More
Supplying, providing and filling fine sand in trenches in stretches other than normal soil and hard rock / boulder stretch (including additional 150mm deep trenching) around mainline pipe for providing a minimum padding thickness of 150 mm on top as well as at bottom of the mainline pipe for the complete specified trench width NOTE: (i) Item to be operated under specific instructions from Engineer-in-Charge (ii) Cost of additional depth of 150mm trenching for this item shall be in cluded in this item itself

-

-

-

... More
4" SWMG ANSI 300#

10

4849

-

... More
Spreading of sludge, dump manure and/or good earth in required thickness including removal of debris/ un-wanted material, consolidat ion, dressing, levelling and watering etc. complete as per directions of the Engineer-in-Charge. [Note: Cost of sludge, dump manure and/or good earth shall be paid separately under relevant item of SOR].

26

1848

-

... More
Providing and placing on terrace (at all floor levels) polyethylene water storage tank (Ref. Make: SINTEX or approved equivalent), I S:12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but with out fittings and the base support for tank.

2500

28969

-

... More
INSTALLATION OF CONTROL PANEL/CONSOLE DESK/ UPS/ RIO/ RTU/ PLC/ ACDB - Taking delivery, shifting the panels to installaion site and erection, installation, testing of Control panels, mounted with all the instruments, power supply units, UPS & battery banks logic control systems , barriers, providing assistance to control system vendor for commissioning of control system including panels, cont rol/console desk etc. installation on already made foundations or fixing on walls, or steel structure or fixtures aligning, levellin g, grouting, inter-wiring outgoing, incoming cable terminations as required, earthing, testing, complete in all respects as per draw ings, specifications and directions of the engineer in-charge/site engineer, including supply of suitable size non-flame proof cable glands for all incoming/outgoing cables and the cost of the materials, tools, labour, glanding, ferruling etc. complete in all resp ects.The indicated quantity is cumulative weight of panels.

16000

714230

-

... More
Type B Delivery Hoses of 15 M length bearing IS-636 mark

20

184009

-

... More
"Above Ground Equipments Installation: Scrapper Launching/ Receiving Barrel along with all accessories, JIB Crane, PIG handling tray , etc as applicable. Taking delivery of equipments, shifting/transporting within station premises, placing on pre-constructed founda tions, assembling together all sub-assemblies, levelling, alignment, grouting, cleaning and flushing by water, draining, checking, t esting, dressing and making good of the foundation and completing the work in all respects in accordance with the relevant drawings , manufacturer's installation instruction, specifications and instructions of Site Engineer / EIC., Note: Weight of equipment is indicative only, Payment shall be done based on actual weight of equipment"

3

140258

-

... More
Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diam eter, 1.8 m long complete as per standard design :

-

-

-

... More
Providing and applying fibre reinforced elastomeric liquid water proofing membrane with resilient acrylic polymers having Sun Reflec tivity Index (SRI) of 105 on top of concrete roof in three coats @ 10.76 litre/10 sqm. One coat of self-priming of elastomeric water proofing liquid (dilution with water in the ratio of 3:1) and two coats of undiluted elastomeric waterproofing liquid (dry film thi ckness of complete application/ system not less than 500 microns). The operation shall be carried out after scrapping and properly c leaning the surface to remove loose particles with wire brushes, complete in all respect as per directions of the Engineer-in-Charge .

758

414877

-

... More
3", 150#/300#, F/F

2

8991

-

... More
Providing and fixing on wall face Unplasticised Rigid PVC (uPVC) rainwater pipes (110 mm diameter, single socketed) conforming to IS :13592 Type-A, including jointing with seal ring conforming to IS:5382, leaving 10 mm gap for thermal expansion.

58

23298

-

... More
STEEL WORK :

-

-

-

... More
Trenching for laying of HDPE in Independent trench Excavation in unpaved areas of earth in work sites for conventional cable trenches for a depth upto 1.65 metres including shoring, strutting etc. (if necessary), backfilling the trench, as directed by Engineer-in-charge/ Site Engineer, including all labour and materials complete as per drawings and tender specifications

742.5

204703

-

... More
301 - 500 METERS (with OFC conduit)

-

-

-

... More
Providing and laying Glazed Vitrified Tiles (polished finish) of specified sizes (thickness to be specified by the Manufacturer) wit h water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacture, in all colours and shades, laid on 2 0 mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 Kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only. Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, levelling system and rubber mallet for placing the tiles gently and easily :

-

-

-

... More
1" NB - Double Cut Joint

1

2689

-

... More
All works upto plinth level

1

11059

-

... More
Supply of full range (upto 8 feet) RF iD Disk type Electronic Markers as per tender specifications

255

628950

-

... More
6" WNRF 300#

50

166144

-

... More
15 mm cement plaster on the rough side of single or half brick wall of mix :

-

-

-

... More
Silent Diesel Generating Set - Supply of Silent Type DG set along with processor based AMF system, Industrial Lead-Acid Batteries fo r Starting of DG Set, Acoustic Enclosure, exhaust piping with its support structure, internal fuel tank of 12 hrs. capacity etc., as given in the technical specification complete in all respects:

-

-

-

... More
WOOD & PVC WORK :

-

-

-

... More
SAFETY EQUIPMENT Supplying the following Safety Equipment as per directions of Site Engineer / Engineer -in-Charge complete in all respects including transportation charges:

-

-

-

... More
Type D (With Ingress Protection IP:55)

2

42376

-

... More
Providing and fixing Plaster of Paris (POP) false ceiling consisting of framework made with 50 sq.mm. M.S. tubes of 18G thickness as main runners at 600 mm c/c both ways, suspended/ supported with M.S. flats 25x4 mm from existing R.C.C. slab including providing an d fixing minimum 10 mm thick POP (Calcium Sulphate Semihydrate variety) jute reinforced tiles of 600x600 mm size of plain or of appr oved design finished smooth to line and level including necessary supports, scaffolding etc. as required including applying a coat o f red oxide zinc chromate primer over the M.S. framework and suspenders, etc. complete in all respects inclusive of cost of all labo ur, materials, tools, tackles etc. as per drawings, specifications and directions of the Engineer-in-Charge.

43

122095

-

... More
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in :

-

-

-

... More
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishi ng and reinforcement - All work up to plinth level :

-

-

-

... More
8.625" ODx 0.250" WT IS3589 FE410 Pipe

20

132230

-

... More
Fasteners for Flanges 4" x 150# (0.625" Dia. X 4.00" Length)

280

21476

-

... More
For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittin gs wherever required including the cost of EPDM rubber/ neoprene gasket required. [Note: Fittings shall be paid for separately] :

-

-

-

... More
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut Granite (of any colour and s hade) for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour an d texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matc hing pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels :

-

-

-

... More
Providing and fixing 15mm diameter C.P. brass tap as per following with C.P. brass flange including cutting & making good the walls wherever required, etc. complete in all respects inclusive of cost of all materials, labour, tools, tackles etc. as per specificatio ns and directions of the Engineer-in-Charge :

-

-

-

... More
8" BLRF 150#

2

6888

-

... More
Supply of Transition pits for building entry points as per tender specifications

222

3150716

-

... More
40 mm nominal dia pipes

37

26151

-

... More
Supplying and fixing circular/ hexagonal M.S. Sheet ceiling fan box with clamp, 140 mm internal diameter, 73 mm height, 3 mm thick r im bottom, and top lid of 1.5 mm thick, M.S. sheet lids shall be screwed into the M.S. box by means of 3.0 mm diameter round headed screws, clamp shall be made of 12 mm diameter M.S. bar bent to shape as per standard drawings with over all length as 80 cm complete in all respects inclusive of cost of all labour, materials, tools, tackles etc. as per drawings, specifications and directions of t he Engineer-in-Charge.

13

2948

-

... More
Installation of Swing Check Valve: Taking delivery of valves of all types and pressure rating from the designated location within st ation premises, transporting the same to site, erecting above ground on preconstructed foundations or underground including earth wo rk in excavation and filling for under ground valves at elevations specified in the drawings, priming and painting of above ground v alves, PU Painting of under ground portions (if applicable) or flood coating and wrapping of under ground portions (if applicable) including all inputs, labour, material and consumable (other than those specifically undertaken to be supplied by the owner) and com pleting the work in all respects in accordance with the drawings, manufacturer's installation instructions and specifications and in structions of the Site Engineer / EIC.

-

-

-

... More
6 NPS (6.625" OD x 0.250"/ 0.280" WT) API 5L/ ASTM A106/ A333/ A53 Pipe

330

1380812

-

... More
Providing and fixing soil, waste and vent pipes :

-

-

-

... More
Weather shade, Chajjas, corbels, etc. including edges.

78

78754

-

... More
Boring with hydraulic piling rigs with power units, providing and installing cast in situ single under reamed piles of specified dia meter and length below pile cap in M-25 cement concrete, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and the length of the pile to be embedded in pile cap etc. all complete. [Note: Length of pile for payment shall be measured upto to the bottom of pile cap] :

-

-

-

... More
Providing and fixing, on fixed glazing/ doors/ window panes, sun control film "HP NATURAL 35 SAFETY COMBINATION FILM-4Mil" of M/s. G ARWARE or approved equivalent make and shade, all complete as per manufacturer's specification and as per directions of the Engineer -in-Charge.

93

122790

-

... More
With float glass panes of 5.50 mm thickness

75

128035

-

... More
Solid State Decoupling Device

62

4966385

-

... More
FLOW METER INSTALLATION - Taking delivery, shifting to installation site within the station premises, erecting and installing of the flow meter along with reducers and flow meter electronics/ flow transmitter. Providing assistance to control system vendor/meter su pplier in testing and commissioning of the turbine/ ultrasonic / coriolis mass flow meter / clamp on ultrasonic ete etc.. Making str uctural supports and fittings, clamps, screws, nuts, bolts, making the cable supports and terminating cables at panel and field ends . Mounting the junction boxes as per drawings,manufacturer's instructions, specification and direction/instruction of engineer in-ch arge/site engineer. Job shall include termination of cables at both fiels ends and control panel ends, supply of suitable size non-f lame proof cable glands at control panel and the cost of all labour, tools, materials, etc. including labelling, tagging using SS pl ates painting, glanding, ferruling complete in all respect.

3

79174

-

... More
1" NB - Single Cut Joint

1

2166

-

... More
Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in widt h as well as 10 sqm on plan) including getting out and disposal of excavated earth, all works up to any lead and lift, as directed b y the Engineer-in-Charge :

-

-

-

... More
Installation, laying of Cat 6 LAN Cables in 16 mm/ 25 mm/ 32 mm PVC conduits from network switch through ceiling/wall/trench and post-laying end to end testing of cables. The job includes supply, installation & fixing of Duplex (2 port) Face plate (Network I/O point) (white/ cream colour) for Local Area Network including RJ45 I/O, modular plate & switch box/ gang box for fixing the face plate & accessories, supply and installation of PVC Conduits, all required materials such as fixing clamps, screws, cable straps, tags etc. as required complete in all respects as per specifications & scope of work, drawings and directions of Site Engineer/ Engineer-in-charge including cost of all labour, tools & tackles, materials etc.

500

68959

-

... More
10"x2" X 150# Weld-o-let

4

8774

-

... More
"SHOCK TREATMENT CHART: Supply and installation of shock treatment chart framed in good quality glass in English / Hindi / Local Language."

13

33050

-

... More
6", 600#/900#, F/F

3

35906

-

... More
Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections.

81

6281

-

... More
On W.B.M/ W.M.M. @ 0.4 Kg/sqm

150

3288

-

... More
Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :

-

-

-

... More
Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.

5345

4288575

-

... More
200 mm dia

60

101369

-

... More
Automatic type Cathodic Protection Transformer Rectifier (CPTR) unit with 230 V AC input and 25 V,25 A DC output rating with SCADA l inkage facility as per specifications

1

400485

-

... More
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concr ete work, using coarse aggregate as well as fine aggregate derived from natural sources and cement content as per approved design mi x, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, inc luding admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per directions of the Engineer-in-Charge. [Note : Cement content considered in this item is @ 3 30 kg/cum. Excess/ less cement used as per design mix is payable/ recoverable separately.] :

-

-

-

... More
BRICK SOLING: Supply and laying of approved quality 75 mm thick second class brick flat soling with sand filling in the interstices, in cable trenches for protectionincluding the cost of all brick and sand, labour, load and lift charges , tools and tackles etc , a s per drawings, specification and directions of Site Engineer / Engineer-in-Charge.

3550

3573552

-

... More
Two or more coats on new work

59

9443

-

... More
Cement mortar 1:6 (1 cement : 6 coarse sand)

81

809628

-

... More
6.625"

100

43660

-

... More
400 mm diameter piles

10

38861

-

... More
Supervision Charges for installation and commissioning of ER Probe system

2

53970

-

... More
INSTALLATION OF EMERGENCY SHUTDOWN SWITCH: Installation and testing of emergency shut - down (ESD) Push button. This includes mounti ng of termination box as per the drawings, specification and instruction of Engineer in-charge/ Site engineer, replacement of broken glass covers and painting it in red colour.

6

79721

-

... More
Fasteners for Flanges 1" x 600# (0.625" Dia. X 4.00" Length)

128

11479

-

... More
Providing & fixing galvanized chicken wire net 20 Gauge, 20 mm mesh size in plastering work at the junction of RCC Columns/ Beams & brickwork as directed by the Engineer-in-Charge.

1093

308789

-

... More
Internal Work - Concealed in wall: Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for ho t & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This i ncludes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same inclu ding testing of joints complete as per directions of the Engineer-in-Charge :

-

-

-

... More
6.625" in Rocky Soil

100

2442600

-

... More
6" SWMG ANSI 300#

30

19399

-

... More
1" 300# 90 deg LR Bend

50

18172

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.