Electricity Department Tender

View complete overview of Goa Electricity Department Tender

Electricity Department Tender

Works
Electrical and Electronics
Eprocure
Opening Date13 Nov 2023
Closing Date22 Dec 2023
Tender Amount₹ 37,09,057 
Notes
Download

Costs

  • EMD

    ₹ 74,181
  • Document Cost

    ₹ 500
  • Tender Fee

    ₹ 6,000

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Tender for renovation of electrical network at Shekre Bagwada and Gandhinagar in Khandepar Village under Village Panchayat Khandepar under jurisdiction of Usgao section office Sub Div II Div X Ponda Goa
Tender for renovation of electrical network at Shekre Bagwada and Gandhinagar in Khandepar Village under Village Panchayat Khandepar under jurisdiction of Usgao section office Sub Div II Div X Ponda Goa
Tender for renovation of electrical network at Shekre Bagwada and Gandhinagar in Khandepar Village under Village Panchayat Khandepar under jurisdiction of Usgao section office Sub Div II Div X Ponda Goa
Tender for renovation of electrical network at Shekre Bagwada and Gandhinagar in Khandepar Village under Village Panchayat Khandepar under jurisdiction of Usgao section office Sub Div II Div X Ponda Goa
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Erection of Disc insulators 70 KN 3-bolted type hardware fitting 70KN suitable for 11KV ball and socket type disc insulators of 18mm pin, failing load of 70KN. Conform to IS-2486 Part 1-1993, 2486 Part 2-1989 as amended upto date.

36

6876

191

... More
Supply of AL. Crimping lug 150 sq.mm

32

1984

62

... More
FRP Fencing for DT(4MX3MX2M)(0.3X0.3X0.5)

2

70000

35000

... More
Supply of HDGI 'X' arm clamps for RCC Pole 9.00 mtr S.A. (Dimensions/specifications as per drawing no. CEE/E-524)

23

6118

266

... More
AL. Crimping lug 150 sq.mm

32

3040

95

... More
Supply of Lightening Arrestors 9KV 5 KA Type: Gapless Type, Applicable standards: IEC 60099-4 & IS: 3070-1993 (part-3) No of units per arrester: Single unit of 9kV, Highest system voltage: 12kV, Normal system voltage: 11kV, System earthing: Solidly earth system, Rated Voltage in kV (RMS): 9kV No of units per arrester: Single unit of 9kV, Highest system voltage: 12kV, Normal system voltage: 11kV, System earthing: Solidly earth system, Rated Voltage in kV (RMS): 9kV Long duration discharge class: Discharge class-II Maximum Continuous Operating Voltage (kV): 7.65Vrms a) One Min. Power Frequency withstand Voltage(Dry&Wet): 28kVrms b) Lightning Impluse Withstand Voltage: 75 VpeakMax. residual voltage for discharge current of 8/20μ seconds a) 5000 Amps: 25kVpeak b) 10000 Amps: 27kVpeak c) 20000 Amps: 30kVpeak Maximum steep current Impluse Residual Voltage at 10kA of I μ second front Time: 30kVpeak Maximum Switching Impluse Residual voltage 30/60μ second at 500 Amps: 24kVpeak Minimum energy discharge capability: 5kJ/kV (OD test - 2 shots) Mounting flange dimensions: 3 slots on PCD

6

18198

3033

... More
Supply of G.I. Nuts & Bolts 100x16mm

150

34200

228

... More
Erection of HDGI Top fitting cross arm ISMC channel, ISMC 75 (75 x 40mm), 0.7mts long for 11KV, Cross arm not to be welded/joined at any place.

33

7524

228

... More
Supply of GNAT' conductor 7/2.21 mm nominal aluminium area 25mm² (80 amps max. at 40° C)

13.85

350308

25293

... More
Supply of HDGI stay clamps for RCC Pole 11.00Mts L.A., (Dimensions/specifications as per drawing no. CEE/E-711)

42

26082

621

... More
Erection of Break insulators 15 KV (88KN) Guy strain insulators of size 140 x 85mm. with minimum failing load of 88 KN and minimum creepage distance of 57 mm. confirming to fig 1 and designation ‘A’ of IS:5300/1969 as amended upto date.

42

4536

108

... More
Erection ofHDGI Structure Material With Clamps

760

35720

47

... More
Erection of G.I. Stay rod & plate LT/11KV line (as per drawing no. CEE/E-465 R)

55

97845

1779

... More
Erection of Distribution Boxes (M.S) with 400Amps MCCB & Kit-Kat fuses As per drawing No.CEE/E-689 Revision No.3 alongwith 12 nos. of 200A Kitkat Porcelain fuse carrier and base with extended terminals conforming in general to drawing No.EE-II/7/2002 with 1 no. moulded case circuit breaker (MCCB), 415V, AC, 50Hz with extended terminals conforming to IS 13947-2 as amended upto date.

2

17590

8795

... More
Erection of HDGI stay clamps for RCC Pole 7.5 mtr L.A., (Dimensions/specifications as per drawing no. CEE/E-523)

13

897

69

... More
Erection of Break insulators 8 KV (44KN): Guy strain insulators of size 90 x 65 mm. with minimum failing load of 44 KN and minimum creepage distance of 41 mm . confirming to fig 1 and designation ‘A’ of IS:5300/1969 as amended upto date. Insulators shall have markings and packing as prescribed in IS. Acceptance tests and routine tests shall be carried out as per IS and test results shall be furnished by the manufacturer before supply of materials.

13

1261

97

... More
Erection of G.l stay wire 7/10 SWG The Stay wire shall comply with the specific requirements of IS: 2141-1979, IS: 4826-1979 & IS: 6594-1974 or the latest versions thereof. The wires shall be of tensile grade 4 & having minimum tensile strength of 700 N/mm2 conforming to IS: 2141. HDGI stay wire standard of size 7/3.15mm (7/10SWG) wire should conform to ISS-2141/68 grade I and hot dipped galvanized as per IS 4826/1968 with up to date amendments.(Galvanising should be hot dipped Galvanised as per IS:2629/66, minimum Zinc coating of 1000 gms/sq.mtr, 140 Microns DFT), suitable for high salinity coastal areas

165.3

10248

62

... More
Erection of Lightening Arrestors 9KV 5 KA Type: Gapless Type, Applicable standards: IEC 60099-4 & IS: 3070-1993 (part-3) No of units per arrester: Single unit of 9kV, Highest system voltage: 12kV, Normal system voltage: 11kV, System earthing: Solidly earth system, Rated Voltage in kV (RMS): 9kV No of units per arrester: Single unit of 9kV, Highest system voltage: 12kV, Normal system voltage: 11kV, System earthing: Solidly earth system, Rated Voltage in kV (RMS): 9kV Long duration discharge class: Discharge class-II Maximum Continuous Operating Voltage (kV): 7.65Vrms a) One Min. Power Frequency withstand Voltage(Dry&Wet): 28kVrms b) Lightning Impluse Withstand Voltage: 75 VpeakMax. residual voltage for discharge current of 8/20μ seconds a) 5000 Amps: 25kVpeak b) 10000 Amps: 27kVpeak c) 20000 Amps: 30kVpeak Maximum steep current Impluse Residual Voltage at 10kA of I μ second front Time: 30kVpeak Maximum Switching Impluse Residual voltage 30/60μ second at 500 Amps: 24kVpeak Minimum energy discharge capability: 5kJ/kV (OD test - 2 shots) Mounting flange dimensions: 3 slots on PCD

6

1044

174

... More
Erection of HDGI 2 pin 'X' arm of ISMC 75 (75 x 40 mm) M.S. Channel 0.75 mtr length, Cross arm not to be welded/joined at any place, (Dimensions/specifications as per drawing no: CEE/E/704).

150

34800

232

... More
Erection of HDGI 'X' arm clamps for RCC Pole 7.5 mtr S.A., (Dimensions/specifications as per drawing no. CEE/E-523)

4

128

32

... More
Erection of G.O.A.B. Switch 11 KV 400 Amps with operating pipe support of class B, 25mm dia. HDGI

2

7978

3989

... More
Erection of G.I. Turn Buckle with eye bolt 11 KV (as per drawing no. CEE/E-500)

55

14685

267

... More
Erection of RCC poles 9.00 mtr long as per Drawing CEE/C-836

29

127832

4408

... More
Removal of 4 Pin X arm channel

80

10440

130.5

... More
Erection ofHDGI stay clamps for RCC Pole 9 mtr L.A., (Dimensions/specifications as per drawing no. CEE/E-524)

8

632

79

... More
Removal & restringing of ant conductor

3.5

34828

9951

... More
Erection of 100KVA Dist Transformer Eneff level ll

2

22034

11017

... More
Supply of HDGI Structure Material With Clamps

760

128440

169

... More
Erection of DTC Metering Unit

2

1306

653

... More
Erection of XLPE 1C unarmoured 150 sqmm 1.1 KV grade

352

48576

138

... More
Supply of HDGI 'X' arm clamps for RCC Pole 7.5 mtr L.A. (Dimensions/specifications as per drawing no. CEE/E-523)

160

29440

184

... More
Supply of 11KV disc Insulator 70KN

36

48096

1336

... More
Removal of 7.5 mtr RCC pole

21

38734

1844.5

... More
Erection of L.T.Shackle Insulators brown glazed shackle insulators of size 100mm x 115mm conforming to fig.No.4 and type 2 of IS: 1445/77 as amended upto date. Minimum failing load shall be 16kN. (i) Insulators shall have marking and packing as prescribed in IS. Acceptance tests and routine tests shall be carried out as per IS at manufacturers works and test results shall be furnished by the manufacturer before supply of materials. Acceptance tests and routine tests shall be carried out as per IS and test results shall be furnished by the manufacturer before supply of materials.

540

112320

208

... More
Danger board 400V

4

228

57

... More
Supply of L.T.Shackle Insulators brown glazed shackle insulators of size 100mm x 115mm conforming to fig.No.4 and type 2 of IS: 1445/77 as amended upto date. Minimum failing load shall be 16kN. (i) Insulators shall have marking and packing as prescribed in IS. Acceptance tests and routine tests shall be carried out as per IS at manufacturers works and test results shall be furnished by the manufacturer before supply of materials. Acceptance tests and routine tests shall be carried out as per IS and test results shall be furnished by the manufacturer before supply of materials.

540

90180

167

... More
Erection ofHDGI 'X' arm clamps for RCC Pole 9.00 mtr L.A., (Dimensions/specifications as per drawing no. CEE/E-524)

46

2070

45

... More
Erection of HDGI 'X' arm clamps for RCC Pole 7.5 mtr L.A. (Dimensions/specifications as per drawing no. CEE/E-523)

160

5120

32

... More
Supply of Break insulators 8 KV (44KN): Guy strain insulators of size 90 x 65 mm. with minimum failing load of 44 KN and minimum creepage distance of 41 mm. confirming to fig 1 and designation ‘A’ of IS:5300/1969 as amended upto date. Insulators shall have markings and packing as prescribed in IS. Acceptance tests and routine tests shall be carried out as per IS and test results shall be furnished by the manufacturer before supply of materials.

13

2288

176

... More
Erection of ANT' conductor 7/3.10 mm nominal aluminium area 50mm² (190 amps max. at 40° C)

13.7

90885

6634

... More
Supply of HDGI X arm clamps for RCC Pole 11.00 mtr L.A, (Dimensions/specifications as per drawing no. CEE/E-711)

43

17802

414

... More
Supply of G.I. Stay rod & plate LT/11KV line (as per drawing no. CEE/E-465 R)

55

132220

2404

... More
Supply of HDGI 'X' arm clamps for RCC Pole 9.00 mtr L.A., (Dimensions/specifications as per drawing no. CEE/E-524)

46

12236

266

... More
Errection of RCC poles 11.00 mtr long as per Drawing CEE/C-698

21

180600

8600

... More
Erection of 11 KV Pin Insulators 11 KV brown glazed porcelain pin insulator with minimum failing load of 5 KN and the Minimum creepage distance of 320 mm conforming to IS 731-1971 as amended upto date. Insulators shall be marked and packed as per IS. Routine tests and acceptance tests as per IS shall be carried at the manufacturers works and test results shall be furnished before supply of materials.

81

6156

76

... More
Erection Cost

-

-

-

... More
Erection of XLPE 1C unarmoured 185 sqmm 1.1 KV grade

88

14960

170

... More
Erection of HDGI X arm clamps for RCC Pole 11.00 mtr L.A, (Dimensions/specifications as per drawing no. CEE/E-711)

43

2795

65

... More
Supply of GI pin for LT Pin insulators Forged G. I. Pin conforming to IS 7935/1975 as amended upto date suitable for L.T. porcelain pin insulator type 1 conforming to fig.1 of IS: 1445/77 with amendment No. 2, Feb.1981, of size 100 x 70 mm. G. I. pin shall comprise of G. I. nut and spring washer and conform to fig. No. 2 of IS: 7935/1975. Minimum failing load of pin shall be 3.5 KN. The fitting shall be marked with the manufacturer’s name or trade mark as per IS. The packing shall be as per IS. G. I. pins and nuts shall be hot dip galvanized as per IS: 2629/66 as amended up to date. The washers shall be electro galvanized. Acceptance tests and Routine tests shall be carried out at the manufacturers works and test reports shall be furnished before supply of materials.

460

58420

127

... More
Supply of Break insulators 15 KV (88KN) Guy strain insulators of size 140 x 85mm. with minimum failing load of 88 KN and minimum creepage distance of 57 mm. confirming to fig 1 and designation ‘A’ of IS:5300/1969 as amended upto date.

42

8736

208

... More
Supply of G.l stay wire 7/10 SWG The Stay wire shall comply with the specific requirements of IS: 2141-1979, IS: 4826-1979 & IS: 6594-1974 or the latest versions thereof. The wires shall be of tensile grade 4 & having minimum tensile strength of 700 N/mm2 conforming to IS: 2141. HDGI stay wire standard of size 7/3.15mm (7/10SWG) wire should conform to ISS-2141/68 grade I and hot dipped galvanized as per IS 4826/1968 with up to date amendments.(Galvanising should be hot dipped Galvanised as per IS:2629/66, minimum Zinc coating of 1000 gms/sq.mtr, 140 Microns DFT), suitable for high salinity coastal areas

165.3

23307

141

... More
Supply of HDGI 'X' arm clamps for RCC Pole 7.5 mtr S.A., (Dimensions/specifications as per drawing no. CEE/E-523)

69

12696

184

... More
Erection of G.I Pin for 11KV Pin Insulator Forged G. I. Pin conforming to IS 2486 part 1 & 2 as amended upto date suitable for 11 KV glazed porcelain pin insulators conforming to IS: 731/71 as amended upto date. G. I pin shall conform to reference S-165 N fig. 5 of IS: 2486/ (part-II)/74 as amended upto date. Dimensions ‘X’ in said fig. shall be 150 mm (screwed 100 mm). Pin shall be supplied along with one suitable G. I. hexagonal nut and G. I. spring washer. Minimum failing load of pin shall be 10 KN.

81

6156

76

... More
Erection of HDGI 11 KV V-shape 'X' arm of channel ISMC 75 (75 x 40mm)

25

8450

338

... More
Supply of G.I Pin for 11KV Pin Insulator Forged G. I. Pin conforming to IS 2486 part 1 & 2 as amended upto date suitable for 11 KV glazed porcelain pin insulators conforming to IS: 731/71 as amended upto date. G. I pin shall conform to reference S-165 N fig. 5 of IS: 2486/ (part-II)/74 as amended upto date. Dimensions ‘X’ in said fig. shall be 150 mm (screwed 100 mm). Pin shall be supplied along with one suitable G. I. hexagonal nut and G. I. spring washer. Minimum failing load of pin shall be 10 KN.

81

19359

239

... More
G.I Earthing SET with charcoal and pipe brick

12

53136

4428

... More
Material Cost

-

-

-

... More
Removal of G.I pin for L.T.Pin

320

27680

86.5

... More
Supply of Disc insulators 70 KN 3-bolted type hardware fitting 70KN suitable for 11KV ball and socket type disc insulators of 18mm pin, failing load of 70KN. Conform to IS-2486 Part 1-1993, 2486 Part 2-1989 as amended upto date.

36

55800

1550

... More
Erection of HDGI X arm clamps for RCC Pole 11.00 mtr S.A, (Dimensions/specifications as per drawing no. CEE/E-711)

11

1078

98

... More
XLPE 1C unarmoured 150 sqmm 1.1 KV grade

352

70752

201

... More
Supply of HDGI 11 KV V-shape 'X' arm of channel ISMC 75 (75 x 40mm)

25

36725

1469

... More
Erection of RCC poles 7.5 mtr long as per Drawing CEE/C-837

44

162316

3689

... More
Danger board 400V

4

992

248

... More
Supply of HDGI stay clamps for RCC Pole 9 mtr L.A., (Dimensions/specifications as per drawing no. CEE/E-524)

8

3928

491

... More
Erection of G.I Earthing SET with charcoal and pipe brick

12

31980

2665

... More
FRP Fencing for DT(4MX3MX2M)(0.3X0.3X0.5)

2

153334

76667

... More
G.I. Nuts & Bolts 100x16mm

150

4500

30

... More
Erection of H.G.Fuse unit 11KV 200AMPS

2

6736

3368

... More
Supply of HDGI 2 pin 'X' arm of ISMC 75 (75 x 40 mm) M.S. Channel 0.75 mtr length, Cross arm not to be welded/joined at any place, (Dimensions/specifications as per drawing no: CEE/E/704).

150

85350

569

... More
Erection of HDGI 4 pin 'X' arm of ISMC 75 (75 x 40mm) M.S. Channel 1.5 mtr length, Cross arm not to be welded/joined at any place, Galvanising should be hot dipped (Dimensions/specifications as per drawing no: CEE/E/705).

150

39150

261

... More
Al. Crimping lug 185 sq.mm

16

1248

78

... More
Supply of HDGI X arm clamps for RCC Pole 11.00 mtr S.A, (Dimensions/specifications as per drawing no. CEE/E-711)

17

7038

414

... More
Erection of L.T. Pin Insulators L. T. brown glazed porcelain pin insulators of size 100mm x 70mm conforming to type 1 fig 1 of IS:1445/1977 with amendment 2 of Feb.1981 (second revision) as amended upto date. Minimum failing load shall be 3.5kN. Insulators shall have marking and packing as prescribed in IS. Acceptance tests and routine tests shall be carried out as per IS at manufacturers works and test results shall be furnished by the manufacturer before supply of materials.

460

79580

173

... More
Supply of Metal parts for L.T Shackle Insulators G. I hardware suitable for L. T. shackle insulators of size 100 x 115 mm. conforming to type 2, fig. 4 of IS: 1445/77 as amended upto date. Hardware or fitting shall conform to fig. 4 of IS 7935-1975 as amended up to date, comprise of 2 G. I. strips, 2 G. I. bolts and 2 nuts with spring washers. All metal parts including nut bolts should be hot dip galvanized as per IS: 2629/66 as amended up to date. Spring washers shall be electro galvanized, (Galvanising should be hot dipped Galvanised as per IS:2629/66, minimum Zinc coating of 1000 gms/sq.mtr, 140 Microns DFT), suitable for high salinity coastal areas. Acceptance tests and routine tests shall be carried out as per IS and test results shall be furnished by the manufacturer before supply of materials. Department reserves the right to witness all the above tests.

540

110700

205

... More
Removal of 2 Pin X arm channel

75

8700

116

... More
Erection of HDGI stay clamps for RCC Pole 11.00Mts L.A., (Dimensions/specifications as per drawing no. CEE/E-711)

42

4116

98

... More
Removal of LT shackle insulator

250

26000

104

... More
Removal ANT conductor

10.9

36155

3317

... More
Erection of ACSR conductor 'WEASEL' 6 +1 / 2.59 mm nominal aluminium area 30mm² (139 amps max. at 45° C)

6.85

48703

7110

... More
Supply of DTC Metering Unit

2

51376

25688

... More
Erection of11KV disc Insulator 70KN

36

6624

184

... More
XLPE 1C unarmoured 185 sqmm 1.1 KV grade

88

21560

245

... More
Supply of 11 KV Pin Insulators 11 KV brown glazed porcelain pin insulator with minimum failing load of 5 KN and the Minimum creepage distance of 320 mm conforming to IS 731-1971 as amended upto date. Insulators shall be marked and packed as per IS. Routine tests and acceptance tests as per IS shall be carried at the manufacturers works and test results shall be furnished before supply of materials.

81

36774

454

... More
Removal & restringing of Gnat conductor

3.8

35243

9274.5

... More
Erection of HDGI X arm clamps for RCC Pole 11.00 mtr S.A, (Dimensions/specifications as per drawing no. CEE/E-711)

17

1105

65

... More
Supply of L.T. Pin Insulators L. T. brown glazed porcelain pin insulators of size 100mm x 70mm conforming to type 1 fig 1 of IS:1445/1977 with amendment 2 of Feb.1981 (second revision) as amended upto date. Minimum failing load shall be 3.5kN. Insulators shall have marking and packing as prescribed in IS. Acceptance tests and routine tests shall be carried out as per IS at manufacturers works and test results shall be furnished by the manufacturer before supply of materials.

460

62560

136

... More
Erection of HDGI 'X' arm clamps for RCC Pole 7.5 mtr S.A., (Dimensions/specifications as per drawing no. CEE/E-523)

69

2208

32

... More
Supply of G.I. Turn Buckle with eye bolt 11 KV (as per drawing no. CEE/E-500)

55

37235

677

... More
Al. Crimping lug 185 sq.mm

16

1520

95

... More
Erection of HDGI 'X' arm clamps for RCC Pole 9.00 mtr S.A. (Dimensions/specifications as per drawing no. CEE/E-524)

23

1035

45

... More
Removal GANT conductor

10.85

33542

3091.5

... More
Supply of HDGI Top fitting cross arm ISMC channel, ISMC 75 (75 x 40mm), 0.7mts long for 11KV, Cross arm not to be welded/joined at any place.

33

27027

819

... More
Supply of HDGI 4 pin 'X' arm of ISMC 75 (75 x 40mm) M.S. Channel 1.5 mtr length, Cross arm not to be welded/joined at any place, Galvanising should be hot dipped (Dimensions/specifications as per drawing no: CEE/E/705).

150

146250

975

... More
Erection of GNAT' conductor 7/2.21 mm nominal aluminium area 25mm² (80 amps max. at 40° C)

13.85

85634

6183

... More
Cut point Channel 1.3 Mtr long

16

7872

492



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.