East Coast Railway Tender

Search from a pool of business opportunities related to Odisha tenders on the online platform of BidAssist. Be it an Odisha PWD tender or a civil aviation tender, one can find every tender Odisha government, as well as PSUs and other organizations, post online. Every tender, active or achieved, is sourced from the eProcurement Odisha website and thus carries full credibility.

East Coast Railway - ECOR Tender

Goods
Electrical Goods and Equipments
Electrical and Electronics
Ireps
Angul - Odisha
+13Hojai, AssamNuapada, OdishaJaunpur, Uttar PradeshRaipur, ChhattisgarhKalahandi, OdishaRayagada, OdishaBalangir, OdishaBalangir, OdishaJajpur, OdishaCuttack, OdishaDhenkanal, OdishaGanjam, OdishaKendujhar, Odisha
Opening Date16 Nov 2023
Closing Date15 Dec 2023
Tender Amount₹ 72,65,96,689 
Notes
Download

Costs

Summary

Provision Of Intrusion Detection System For Detection Of Elephant Movements With Tracking and Level Crossing Alerts In Kur Division & Sbp Division Over East Coast Railway. Sbp division:- (mane-bamr,trkr-lkna,arn-anmd,nrlr-thv & Blgr-dfr) Sections. Kur division:- (byy-kis-rjgr-angl, Rba-gam, Nyg-prnr) Sections.

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply Installation and Commissioning of Interface Unit for LC gate controlling station for triggering hooter at LC gate end over pair of quad cable / LTE along with Audio Visual Display for ASM. (Annexure enclosed) Inspection by RDSO.

47

125299

5889079.79

... More
Supply, Installation and commissioning of Alarm unit with hooter at LC Gate as per Technical specification and (Annexure enclosed) Inspection by RDSO.

100

14311

1431161

... More
Supply of 6 Fiber armoured optic fiber cable (OFC) as per Technical Specification, this should be compitable with the existing Railway system. Inspection by RDSO or RITES.

1200000

45

55080000

... More
Supply of OFC Joint enclosure 6 fibres armoured OFC with all accessories and consumables. Inspection by RITES.

300

3233

970008

... More
Double walled corrugated (DWC) pipes Size of Outer Dia 90mm/inner dia 76mm, make electrex 3 /telerex/optirex or similar as per TEC specifications GR/DWC- 34/01, IS 14930 part-II along with socket / coupler and T joints wherever required having IP-67 protection, for underground power /signalling / telecommunication cable protection.Inspection by RITES.

5000

255

1278200

... More
Supply of Driver data console of IDS application having minimum of 7 inch LCD display,2GB RAM,5100mAH battery with Wi-Fi and bluetooth connectivity with its cover and IDS application loaded and SIM cards, or higher as per direction of site supervisor Make LENOVO(M8HD) or similar.Inspection by RDSO.

500

24862

12431250

... More
Supply of 12 port loaded LIU rack mountable, LIU should be provided for terminating the optical fiber cables. It shall provide minimum bending radius and splice trays shall function as a splice cover for Pigtail 5 Splicing. Cable glands shall be provided for secure oring for incoming cables. Rubber grommets shall be provided at the cable entry point for tight sealing. The splice tray should be made of ABS materials. LIU should be of reputed make. Make: D-Link/3M/ Digilink/Molex/ DAX or similar. (Inspection by the representative of Railway ie., Inspection by Representative of Railway.

20

6210

124212.2

... More
Supply of OFC patch cord of 10 mtrs length as Draft RDSO Specn. No. RDSO/SpNII'C/ 69/2007 or letest for connecting fiber to the equipment. lnspection by the Representative of Railway.

80

5552

444168.8

... More
Supply of Layer-2 Switch (minimum 8+2 portmanageable) with 8 nos.10/100/1000 Mbps Ethernet 7 port, PoE and 2 nos. 1000 BaseX SM SFP port with optical modules complete with all accessories etc. as per RDSO spec. No: RDSO/SPN/TC/65/2021 Rev 6.0 or latest, Clause 14.0 (iii). (Inspection by Representative of Railway.)

4

17268

69072.36

... More
Line interactive UPS with AVR of Rating 0.65 KVA with warranty of 1 year, Make:- Microtek/APC/Numaric. Inspection by the Representative of Railway.

51

2349

119849.49

... More
Supply of Mini OTDR along with all accessories, Make: Agilent/Yokogawa Inspection by RITES.

2

513944

1027888.56

... More
Supply of Automatic Fusion Splicing Machine alongwith specification and accessories (as per Section H annexure T3) model No FSM-80S or higher version Make FUJIKURA Inspection by RITES.

2

627239

1254478.8

... More
Excavation of trenches of 1.0 Mtr. depth and width 0.3 Meter including clearing of roots and trees 1 etc. for all types of soil. This work also includes covering of cables laid in trench and backfilling, ramming, consolidation of soil as well as disposal of extra soil after cable is laid as specified in Guidelines on Telecom Cable laying given by RDSO and any latest circular issued by CSTE/ECoR/BBS.

1000

71970

71970000

... More
Laying of OFC cable/Signalling/4 Quad/ 6 Quad/ Power Cable/Telecom cables/ Jelly filled cables of all sizes in excavated trench, through GI/RCC/DWC pipes etc. wherever required. This includes transportation of cables from the stores to work site and transportation of empty cable drums with left over cables from site to the stores at . The length of cable laid includes the length of cable coil for termination purpose. NOTE: The cables are to be carefully handled during loading, un-loading and transportation to work site. Any damage found in the cable after final testing, in view of mishandling of cables, shall be made good by the Tenderer. Cable should be maggered before and after laying and recorded in a register and submitted to the site Engineer.

1200

7030

8436000

... More
Transportation of OFC from the store to work site with care, and pushing/ pulling OFC through the 3 HDPE pipes sealing of the duct by simple plugs. The cable is to be laid by mechanised means. At inaccessible places where mechanised laying is not possible, the cable is to be laid manually by pulling through pre inserted rope. Empty cable drums with or without leftover cable should be returned to the store. This also includes testing of cable drums by OTDR in the store premises before transportation and submission of results thereof.

1200

26723

32068236

... More
"Protection work for cable laying on steel girder culvert/ bridge & PSC girder bridge using 80 mm 4 nominal dia medium grade perforated G. I. pipe with M. S. Clamps for steel girder bridge/ culverts & RCC with 1:2:4 massonary work for PSC girder bridge. Note: All the materials e. g. perforated G. I. pipes (medium grade as per specification IS:1239), M. S. Clamps, masonary materials, nuts and bolts etc. are to be supplied by the contractor. The G.I. pipes are to be inspected by RITES before use."

10000

798

7986400

... More
"Cable crossing of Railway track/road by boring hole at a depth of 1.0 meter (nominal) by using 90/76 mm dia DWC /HDPE pipe with accessories. The work must be executed under the supervision of P. way staff of the Railway. DWC/ HDPE pipe will be supplied by the railway."

6000

127

767580

... More
Installation of O.F. Cable Joint enclosure and splicing of Optic fibre cable as per technical specification and testing. This includes providing of RCC Pit with top and bottom concrete round lid as detailed in technical specification. Supply of OFC joint enclosures is covered under separate item in Schedule.

300

3513

1054101

... More
Supply, transportation to site, erection and concreting the base of RCC OFC joint/route markers at the location of OFC joints and route. The design of the RCC OFC joint/ route markers should be got approved from the Engineer in charge prior to commencement of the work.

8000

475

3800400

... More
Installation, Testing & Commissioning of rack mountable 12 port Loaded LIU. All the accessories and fixing materials required for this installation are to be supplied by contractor within the same cost.

20

98

1975.4

... More
"Submission of the Proposed cable route plan before the cables are laid and commissioned 9 indicating clearly the exact position of the cable, joints, LB for emergency sockets and other critical materials with reference to centre line of the nearest track to be submitted to the Railways in 6 copies. NOTE:- PER UNIT= PER KM."

1000

1622

1622460

... More
"Submission of the final cable route plan after the cables are laid and commissioned indicating 10 clearly the exact position of the cable, joints, LB for emergency sockets and other critical materials with reference to centre line of the nearest track. The final cable route plan and drawings of the cable terminations along with all relevant particulars are to be submitted to the Railways in original master form as well as 6 copies. NOTE:- PER UNIT= PER KM" Per Block

1000

2206

2206840

... More
"Cutting of masonary floor/walls at station building/ signal goomty/ Gate lodge at a depth of 0.5 mtr. 12 to 1.0 mtr at places to be indicated by site Engineer for entering of cables inside the building. with G.I pipes and all materials as clamps, bolts & nuts as instructed by site Engineer supplied by tenderer. This includes repairing of masonary floors/walls after the cables are taken inside. Cement, Sand required for the work shall be supplied by the tenderer .

47

6385

300109.1

... More
Installation, Testing & Commissioning of rack mountable 24 port manageable Layer -2 switch with 4 nos 1000 Base X SM SFP port and 24 nos GE port .All the accessories and fixing materials required for this installation are to be supplied by contractor with in the same cost.

4

518

2075.36



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.