East Coast Railway Tender
Search from a pool of business opportunities related to Odisha tenders on the online platform of BidAssist. Be it an Odisha PWD tender or a civil aviation tender, one can find every tender Odisha government, as well as PSUs and other organizations, post online. Every tender, active or achieved, is sourced from the eProcurement Odisha website and thus carries full credibility.
East Coast Railway - ECOR Tender
Electrical Goods and Equipments
Electrical and Electronics
Ireps
+13Hojai, AssamNuapada, OdishaJaunpur, Uttar PradeshRaipur, ChhattisgarhKalahandi, OdishaRayagada, OdishaBalangir, OdishaBalangir, OdishaJajpur, OdishaCuttack, OdishaDhenkanal, OdishaGanjam, OdishaKendujhar, Odisha
Opening Date16 Nov 2023
Closing Date15 Dec 2023
Tender Amount₹ 72,65,96,689
Costs
EMD
₹ 37,83,000Document Cost
Refer DocumentsTender Fee
Refer Documents
Summary
Provision Of Intrusion Detection System For Detection Of Elephant Movements With Tracking and Level Crossing Alerts In Kur Division & Sbp Division Over East Coast Railway. Sbp division:- (mane-bamr,trkr-lkna,arn-anmd,nrlr-thv & Blgr-dfr) Sections. Kur division:- (byy-kis-rjgr-angl, Rba-gam, Nyg-prnr) Sections.
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
SNTPBBS-072023-IDS-ECOR HQ-S AND T/ECORTender No
SNTPBBS-072023-IDSTender Authority
East Coast Railway ViewPurchaser Address
-Website
http://ireps.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
Supply Installation and Commissioning of Interface Unit for LC gate controlling station for triggering hooter at LC gate end over pair of quad cable / LTE along with Audio Visual Display for ASM. (Annexure enclosed) Inspection by RDSO.
47
125299
5889079.79
Supply, Installation and commissioning of Alarm unit with hooter at LC Gate as per Technical specification and (Annexure enclosed) Inspection by RDSO.
100
14311
1431161
Supply of 6 Fiber armoured optic fiber cable (OFC) as per Technical Specification, this should be compitable with the existing Railway system. Inspection by RDSO or RITES.
1200000
45
55080000
Supply of OFC Joint enclosure 6 fibres armoured OFC with all accessories and consumables. Inspection by RITES.
300
3233
970008
Double walled corrugated (DWC) pipes Size of Outer Dia 90mm/inner dia 76mm, make electrex 3 /telerex/optirex or similar as per TEC specifications GR/DWC- 34/01, IS 14930 part-II along with socket / coupler and T joints wherever required having IP-67 protection, for underground power /signalling / telecommunication cable protection.Inspection by RITES.
5000
255
1278200
Supply of Driver data console of IDS application having minimum of 7 inch LCD display,2GB RAM,5100mAH battery with Wi-Fi and bluetooth connectivity with its cover and IDS application loaded and SIM cards, or higher as per direction of site supervisor Make LENOVO(M8HD) or similar.Inspection by RDSO.
500
24862
12431250
Supply of 12 port loaded LIU rack mountable, LIU should be provided for terminating the optical fiber cables. It shall provide minimum bending radius and splice trays shall function as a splice cover for Pigtail 5 Splicing. Cable glands shall be provided for secure oring for incoming cables. Rubber grommets shall be provided at the cable entry point for tight sealing. The splice tray should be made of ABS materials. LIU should be of reputed make. Make: D-Link/3M/ Digilink/Molex/ DAX or similar. (Inspection by the representative of Railway ie., Inspection by Representative of Railway.
20
6210
124212.2
Supply of OFC patch cord of 10 mtrs length as Draft RDSO Specn. No. RDSO/SpNII'C/ 69/2007 or letest for connecting fiber to the equipment. lnspection by the Representative of Railway.
80
5552
444168.8
Supply of Layer-2 Switch (minimum 8+2 portmanageable) with 8 nos.10/100/1000 Mbps Ethernet 7 port, PoE and 2 nos. 1000 BaseX SM SFP port with optical modules complete with all accessories etc. as per RDSO spec. No: RDSO/SPN/TC/65/2021 Rev 6.0 or latest, Clause 14.0 (iii). (Inspection by Representative of Railway.)
4
17268
69072.36
Line interactive UPS with AVR of Rating 0.65 KVA with warranty of 1 year, Make:- Microtek/APC/Numaric. Inspection by the Representative of Railway.
51
2349
119849.49
Supply of Mini OTDR along with all accessories, Make: Agilent/Yokogawa Inspection by RITES.
2
513944
1027888.56
Supply of Automatic Fusion Splicing Machine alongwith specification and accessories (as per Section H annexure T3) model No FSM-80S or higher version Make FUJIKURA Inspection by RITES.
2
627239
1254478.8
Excavation of trenches of 1.0 Mtr. depth and width 0.3 Meter including clearing of roots and trees 1 etc. for all types of soil. This work also includes covering of cables laid in trench and backfilling, ramming, consolidation of soil as well as disposal of extra soil after cable is laid as specified in Guidelines on Telecom Cable laying given by RDSO and any latest circular issued by CSTE/ECoR/BBS.
1000
71970
71970000
Laying of OFC cable/Signalling/4 Quad/ 6 Quad/ Power Cable/Telecom cables/ Jelly filled cables of all sizes in excavated trench, through GI/RCC/DWC pipes etc. wherever required. This includes transportation of cables from the stores to work site and transportation of empty cable drums with left over cables from site to the stores at . The length of cable laid includes the length of cable coil for termination purpose. NOTE: The cables are to be carefully handled during loading, un-loading and transportation to work site. Any damage found in the cable after final testing, in view of mishandling of cables, shall be made good by the Tenderer. Cable should be maggered before and after laying and recorded in a register and submitted to the site Engineer.
1200
7030
8436000
Transportation of OFC from the store to work site with care, and pushing/ pulling OFC through the 3 HDPE pipes sealing of the duct by simple plugs. The cable is to be laid by mechanised means. At inaccessible places where mechanised laying is not possible, the cable is to be laid manually by pulling through pre inserted rope. Empty cable drums with or without leftover cable should be returned to the store. This also includes testing of cable drums by OTDR in the store premises before transportation and submission of results thereof.
1200
26723
32068236
"Protection work for cable laying on steel girder culvert/ bridge & PSC girder bridge using 80 mm 4 nominal dia medium grade perforated G. I. pipe with M. S. Clamps for steel girder bridge/ culverts & RCC with 1:2:4 massonary work for PSC girder bridge. Note: All the materials e. g. perforated G. I. pipes (medium grade as per specification IS:1239), M. S. Clamps, masonary materials, nuts and bolts etc. are to be supplied by the contractor. The G.I. pipes are to be inspected by RITES before use."
10000
798
7986400
"Cable crossing of Railway track/road by boring hole at a depth of 1.0 meter (nominal) by using 90/76 mm dia DWC /HDPE pipe with accessories. The work must be executed under the supervision of P. way staff of the Railway. DWC/ HDPE pipe will be supplied by the railway."
6000
127
767580
Installation of O.F. Cable Joint enclosure and splicing of Optic fibre cable as per technical specification and testing. This includes providing of RCC Pit with top and bottom concrete round lid as detailed in technical specification. Supply of OFC joint enclosures is covered under separate item in Schedule.
300
3513
1054101
Supply, transportation to site, erection and concreting the base of RCC OFC joint/route markers at the location of OFC joints and route. The design of the RCC OFC joint/ route markers should be got approved from the Engineer in charge prior to commencement of the work.
8000
475
3800400
Installation, Testing & Commissioning of rack mountable 12 port Loaded LIU. All the accessories and fixing materials required for this installation are to be supplied by contractor within the same cost.
20
98
1975.4
"Submission of the Proposed cable route plan before the cables are laid and commissioned 9 indicating clearly the exact position of the cable, joints, LB for emergency sockets and other critical materials with reference to centre line of the nearest track to be submitted to the Railways in 6 copies. NOTE:- PER UNIT= PER KM."
1000
1622
1622460
"Submission of the final cable route plan after the cables are laid and commissioned indicating 10 clearly the exact position of the cable, joints, LB for emergency sockets and other critical materials with reference to centre line of the nearest track. The final cable route plan and drawings of the cable terminations along with all relevant particulars are to be submitted to the Railways in original master form as well as 6 copies. NOTE:- PER UNIT= PER KM" Per Block
1000
2206
2206840
"Cutting of masonary floor/walls at station building/ signal goomty/ Gate lodge at a depth of 0.5 mtr. 12 to 1.0 mtr at places to be indicated by site Engineer for entering of cables inside the building. with G.I pipes and all materials as clamps, bolts & nuts as instructed by site Engineer supplied by tenderer. This includes repairing of masonary floors/walls after the cables are taken inside. Cement, Sand required for the work shall be supplied by the tenderer .
47
6385
300109.1
Installation, Testing & Commissioning of rack mountable 24 port manageable Layer -2 switch with 4 nos 1000 Base X SM SFP port and 24 nos GE port .All the accessories and fixing materials required for this installation are to be supplied by contractor with in the same cost.
4
518
2075.36