Defence Research And Development Organisation Tender

BidAssist is a very user-friendly website that lets us explore new opportunities which further helps in the growth of the business. We can get any information regarding any e-tender the Chhattisgarh government has posted on its website in a very hassle-free manner.

Defence Research And Development Organisation - DRDO Tender

Works
Civil And Construction
Water Storage And Supply
Eprocure
Opening Date9 Nov 2023
Closing Date7 Dec 2023
Tender Amount₹ 1,55,33,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 Sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. a) All kinds of Soils

529

97865

185

... More
Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 Sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge. a) Ordinary Rock

252

104580

415

... More
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.

726

149556

206

... More
Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. Complete. a) Obtained from within MOD Land

845

346450

410

... More
SUBHEAD-II :ANTI TERMITE TREATMENT :

-

-

-

... More
Supplying chemical emulsion in sealed containers including delivery as specified. a) Chlorpyriphos/ Lindane emulsifiable concentrate of 20%

126

34902

277

... More
Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : a) Along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc., with Chlorpyriphos/ Lindane E.C. 20% with 1% concentration.

88

3432

39

... More
Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor, with Chlorpyriphos/ Lindane E.C. 20% with 1% concentration.

188

40232

214

... More
Treatment of existing masonry using chemical emulsion @ one litre per hole at 300 mm interval including drilling holes at 45 degree and plugging them with cement mortar 1:2 (1 cement : 2 coarse sand) to the full depth of the hole, with Chlorpyriphos/ Lindane E.C. 20% with 1% concentration.

68

2108

31

... More
SUBHEAD-III : PLAIN & REINFORCED CEMENT CONCRETE :

-

-

-

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : a) 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size)

77

533764

6932

... More
Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor,etc., up to floor five level, excluding the cost of centering, shuttering and finishing: a) 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 40 mm nominal size)

54

551718

10217

... More
Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth,including necessary excavation ,levelling & dressing & finishing the top smooth,

60

39480

658

... More
Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement, including cost of admixtures in recommended proportions as per IS:9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer - in - charge. (Note :- Cement content considered in this item is @ 330 kg/cum.Excess/less cement used as per design mix is payable/recoverable separately).

-

-

-

... More
a) All works upto plinth level

55

513535

9337

... More
b) All works above plinth level upto floor v level

4

39456

9864

... More
Add/ Deduct for using extra/ less cement in the items of design mix over and above the specified cement content therein.

9

7686

854

... More
Supplying, fabricating and fixing in position reinforcement bars at all levels and positions including the cost of steel, straightening, cutting, bending, binding and placing in position etc., as per drawings and specifications including the cost of binding wire, labour etc., all complete for reinforced concrete. a) Thermo-Mechanically Treated bars (Fe 500 Grade)

5.6

538647

96187

... More
Centering and shuttering including strutting, propping etc. and removal of form for :

-

-

-

... More
a) Foundations, footings, bases of columns, etc. for mass concrete

108

28836

267

... More
b) Lintels, beams, plinth beams, girders, bressumers and cantilevers

66

34980

530

... More
c) Columns, Pillars, Piers, Abutments, Posts and Struts

67

46699

697

... More
d) Weather shade, Chajjas, corbels etc., including edges

3

2232

744

... More
SUBHEAD-IV : STONE & BRICK MASONRY :

-

-

-

... More
Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with, Cement mortar 1:6 (1 cement : 6 coarse sand).

54

315954

5851

... More
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand).

18

153090

8505

... More
SUBHEAD-V : PLASTERING & SURFACE TREATMENT :

-

-

-

... More
Pointing on stone work with cement mortar 1:3 (1 cement : 3 fine sand) : a) Flush/ Ruled Pointing

32

8768

274

... More
6 mm cement plaster of mix cement mortar 1:3 (1 Cement : 3 fine sand).

3

684

228

... More
15 mm cement plaster on the rough side of single or half brick wall of mix 1:6 (1 cement: 6 fine sand).

162

48438

299

... More
18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster 1:6 (1 cement : 6 fine sand).

100

39300

393

... More
Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers.

7

553

79

... More
Providing and fixing 22 gauge chicken mesh wire at the junction of RCC and brick work with overlapping of 100mm on both sides, etc., complete.

18

1386

77

... More
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.

162

18630

115

... More
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface.

162

9558

59

... More
Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour (Two or more coats on new work) complete, as per manufacturer’s specification.

162

12960

80

... More
Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives. a) New work (Two or more coats applied @ 1.43 litre/ 10 Sqm. Over and including priming coat of exterior primer applied @ 0.90 litre/10 Sqm

100

14800

148

... More
Applying priming coat with ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood)

123

6765

55

... More
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade, Two or more coats on new work

123

13161

107

... More
Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm.

50

13250

265

... More
SUBHEAD-VI : FLOORING :

-

-

-

... More
Providing and laying C.C. pavement of mix M-25 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid and finished with screed board vibrator, vacuum dewatering process and finally finished by floating, brooming with wire brush etc. complete as per specifications and directions of Engineer-incharge. (The panel shuttering work shall be paid for separately). (Note:- Cement content considered in this item is @ 330 kg/cum. Excess/ less cement used as per design mix is payable/ recoverable separately).

23

130893

5691

... More
Making provision for contraction, expansion, construction and longitudinal joints (size 5x20mm) by groove cutting machine

15

960

64

... More
Providing and filling in position at expansion joints with poly sulphide sealants.

27

4806

178

... More
52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacturer’s specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc., complete.

113

90626

802

... More
Providing cement skirting in CM (1:3) 18mm thick finished with a floating coat of neat cement etc., complete.

13

6656

512

... More
SUBHEAD-VII : STEEL & WOOD WORKS :

-

-

-

... More
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, Doors work with Shutters etc including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.

8

930320

116290

... More
Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including MS pressed blet hinges 2.50mm thick with morter guards, lock strike plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge: a) Profile B, fixing with adjustable lugs with split end tail to each jamb

32

22976

718

... More
Providing and fixing the following hardware fittings of approved make:

-

-

-

... More
a) 200mm long SS Tower Bolts

7

1729

247

... More
b) SS Aldrop 300mm long

4

648

162

... More
Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete. a) 125mm long

8

1400

175

... More
Providing and fixing aluminium hanging floor door stopper (Single rubber stopper), ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.

7

1253

179

... More
Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete.

3

7716

2572

... More
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.

510

367200

720

... More
Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : Of area beyond 3 sq. metres

2

680

340

... More
Making the opening in brick masonry including dismantling in floor or walls by cutting masonry and making good the damages to walls, flooring and jambs complete, to match existing surface i/c disposal of mulba/ rubbish to the nearest municipal dumping ground, all complete as per direction of Engineer-in-Charge. For door/ window/ clerestory window

6

6282

1047

... More
SUB HEAD-VIII: INTERNAL ELECTRIFICATION

-

-

-

... More
Point Wiring for Light/ Fan/ exhaust fan with 2 runs of 1100V grade 1.5 Sq.mm & 1 run of 1.5 Sq.mm PVC insulated multistrand , FRLS , Copper conductor wires , run in and including 25mm dia heavy gauge PVC conduits concealed in wall / ceiling conforming to IS 732 including all accessories such as junction boxes, conduit bends elbows and anodised GI Switch box with modular switch and the box covered with front plate including connections to Earth terminal.

-

-

-

... More
a) One Light point controlled by one 6 A switch.

30

59970

1999

... More
b) Two Light point controlled by one 6 A switch.

10

27260

2726

... More
c) Ceiling fan point controlled by one 6 A switch and electronic fan regulator of 100 W step type with concealed MS fan hook box.

2

5874

2937

... More
d) Exhaust fan point controlled by one 6 A switch.

5

10155

2031

... More
Supply and fixing of 6A, 3Pin Socket outlet with 6A switch in Lighting switch boards. (Dependant).

5

4085

817

... More
Supply and fixing of 6A, 3Pin Socket outlet with switch of 6A rating with wiring of 2 Runs of 2.5 Sqmm and 1 Run of 2.5 Sqmm FRLS, PVC insulated multistranded Copper conductor wires run in and including 25 mm Dia, 2 mm thick PVC conduit. (Independant).

10

24760

2476

... More
Supply and Wiring with the following size 1100V grade PVC insulated multistrand FRLS Copper conductor wires in and including suitable size heavy gauge PVC conduit concealed in wall / Ceiling including all accessories such as junction boxes, bends, elbows including end terminated with suitable lugs.

-

-

-

... More
a) 2 runs of 2.5 Sq.mm wires with 1run of 2.5 Sq.mm wire in and including 25 mm Dia PVC Conduit (For Lighting Circuit)

300

95100

317

... More
b) 4 runs of 6 Sq.mm wires with 2 runS of 6 Sq.mm wires in and including 32 mm Dia PVC Conduit (For Lighting Sub Mains)

50

38750

775

... More
Supply and Commissioning of the following type Fluorescent/ Compact fluorescent light fixtures on wall/ Ceiling including all fixing accesssories such as leads, etc complete as required. The Fluorescent/CFL fixtures shall be complete with Low loss copper ballast PF improvement capacitor, Bipin Rotor type lamp holder,starter, starter base, all prewired upto the terminal block. All fixtures shall be supplied with lamps. The Catalogue Numbers refers to Philips Make.

-

-

-

... More
a) 36 W Surface mounted LED 4 Feet Length Luminaire (Philips : BN308C LED40S-6500 L120 PSU WH/Equivalent)

24

49176

2049

... More
b) 1 x 12 W Surface Mounted LED Luminaire (Philips Cat No : SM250C LED 12S-6500PSU WH)

5

5120

1024

... More
c) 40 W Recess Mounted LED Light Fixture (Philips Cat No :RC 380 B LED 40S-6500 G4L60W60 PSU OD/Equivalent)

2

8878

4439

... More
d) 20W Recess mounted Down Light Fixture (Philips Cat No DN195B LED20S-6500 PSU WH S2/Equivalent)

1

2817

2817

... More
Supply and commissioning of 305 mm sweep Exhaust fans with Metallic blades and MS gravity louvers including all accessories / Installation materials required.

5

20720

4144

... More
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) a) 8 way (4 + 12), Double door

2

15500

7750

... More
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. a) 40A

2

12348

6174

... More
Supplying and fixing of 6A to 32A rating 240/415V,10kA , C Curve miniature circuit breaker suitable for inductive load of following polesin the existing MCB DB complete with connections ,testing and commissioning etc complete. a) Single Pole

48

18144

378

... More
SUBHEAD-IX : AIR CONDITIONING;

-

-

-

... More
Supply, installation,testing,commissioning of scroll type compressor condenser unit of following capacity including thermostatic expansion valves one per unit each circuit,saftey control and thermostst and plc control panel inter connected control/power cables and other accessories etc.the unit shall be precharged and included with any topup charging at the time of commisioning the control,valves and accessories along with the expansion devices and its seqencitial controller and the expansion devices and its safities shall be included in the cost of the cost of the unit only refrigerant piping between the units shall be measureable a) 8.5TR CONDENSER UNITS

1

167242

167242

... More
Indoor Units Supply, installation ,testing and commissioning of Double skin construction air handling unit made out of extruded aluminum structural frame work and casted polyemide/aluminumcorner/ inter-mediate connecting pieces panel in glavanized sheet casings having scratch free plastisol coating on galvanized sheet.The air handling unit shall comprise of fan section with back curved centrifugal fan & fan motor and motor drive assembly along with frame proof motor,bearings of the fan mounted onthe scroll and not on the casing,coil section comprising of dx coil,hot water coil, hot water to be controlled with PID controllers in conjunction with temp & RH controllers.drain pan made of stainless steel 1mm thick sheet under the fan and coil section,filter section compreising of pre filters & fine filter (10 & 5 micron) etc complete, a) AHU-1 8.5TR 3400cfm 7sqft of coil area 6row coil with 2 1/2" ststic pressure, dx coil 1no 8.5TR CDU,5KW flame proof heater along with safeties

1

234139

234139

... More
Refrigerant Copper Piping Supply, laying, Testing and commissioning of following size hard copper piping for Condenser units with insulation of 6mm thick Nitrile Rubber pre formed sections including supporting fixtures and accessories etc., complete.

-

-

-

... More
a) 5/8" Dia

70

51520

736

... More
b) 7/8" Dia

70

56210

803

... More
Supply, laying, Testing and commissioning of Drain piping with HDPE PVC Pipe 1 1/2" dia as per specification

5

1840

368

... More
Supply, Erection, testing and commissioning of factory fabricated G.I. Ducting as per IS655 and SMACNA standards Galvaised sheet of class VII as per the technical specification

-

-

-

... More
a) 24 Gauge

50

70250

1405

... More
b) 22 Gauge

10

15390

1539

... More
Supply, installation and testing of Canvas connection for the air handling unit to the duct

1

3746

3746

... More
Supply, Fixing, Testing and commissioning of Aluminum powdwe coated cntinous grills & discreet Grills as per specifications including wooden frame as per the site conditions.

5

60205

12041

... More
Supply, Fixing, Testing and commissioning of Duct Dampers

0.5

3680

7359

... More
Supply, Fixing, Testing and commissioning of GI Fire dampers with fusible link

0.5

5352

10704

... More
Supply, Fixing, of Fresh air Dampers and wire mesh ssets including standared fixing accessories etc.,complete

1

6021

6021

... More
Providing thermal insulation with 19mm thick Al foil faced Nitrile material accessories etc complete.

30

26100

870

... More
Providing Accoustic insulation with 13mm Arma sound nitril rubber for ducting

5

3180

636

... More
SUBHEAD-X : POWER WIRING :

-

-

-

... More
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) a) 8 way (4 + 12), Double door

2

15500

7750

... More
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. a) 63A

2

13568

6784

... More
Supplying and fixing of 6A to 32A rating 240/415V,10kA , C Curve miniature circuit breaker suitable for inductive load of following polesin the existing MCB DB complete with connections ,testing and commissioning etc complete. a) Single Pole

30

11340

378

... More
Supply,erection,testing and commissioning of the following switch sockets with anodised G.I. Box, front plate and fixing screws etc . a) 6/16 Amps, 5-pin (250 Volts) single phase modular type socket controlled by 16 Amps SP Switch.

10

12620

1262

... More
Supply and fixing of factory made 25A, 1Ph Metalclad socket with plug top & 25A SPMCB in MS box including all fixing accessories

2

5296

2648

... More
Supply and Wiring with the following size 1100V grade PVC insulated multistrand, FRLS Copper conductor wires in and including suitable size heavy gauge PVC conduit concealed in wall / Ceiling including all accessories such as junction boxes, bends, elbows including end terminated with suitable lugs.

-

-

-

... More
a) 2runs of 4Sq.mm wires with 1run of 4 Sq.mm wire in and including 25mm dia PVC Conduit(For 16A Sockets).

250

92000

368

... More
b) 2runs of 6Sq.mm wires with 1run of 6 Sq.mm wire in and including 25mm dia PVC Conduit(For AC Sockets).

100

49800

498

... More
c) 4runs of 10Sq.mm wires with 2run of 6 Sq.mm wire in and including 25mm dia PVC Conduit.

50

49800

996

... More
Supply, installation, Testing and Commissioning of 3 phase and Neutral 415V, 4 wire Free Standing Floor mounted MV panel made out of 14 SWG MS sheet after seven tankprocess and painting with Epoxy powder coating. The panel shall consist of suitable rating TPN Aluminium busbar (at the rating of 0.8A/Sq.mm) supported with DMC/ SMC barriers and color coded with Heat shrinkable sleeves.The Metering shall be provided as specified. The panel shall have Short circuit withstanding capacity of minimum 50KA and consist of the switchgear as mentioned below. The panel shall be got fabricated from manufacturers with CPRI Test certificate only. The size of all Panel Mounting Meters shall be 96X96mm. The Panels shall be mounted on U channels including supply and fixing of the same. Each panel is to be provided with minimum of two numbers of spare Cubicles.

-

-

-

... More
a) PANEL (INDOOR) Incomer a) 160 A, 50KA, 4P MCCB, Should be supplied with S/C, E/F, O/C Protection.(70 - 100% Plug setting) – 1No b) 2A, control MCB - 3 Nos. Outgoings : a) 63A ,16KA TPN, MCCBs - 8 Nos b) Bus Bar : 160 A TPN Alluminium Bus Bar-1 Set Metering Incomer : a) 0-500V Digital Voltmeter with selector switch and MCB-1set b) CT Operated Load Manager (similar to EM-6400) - 1 No c) 0-160A Digital Ammeter with resin cast CTsof ratio 160/5A Class 1 Accuracy and 15VA burden and selector switch -1set d) LED phase indication lamps with toggle switch -1set

1

284628

284628

... More
Providing and fixing of maintenance free earthing which consists of 40mm Dia, standrad length (as per Equipment Supplier) electrode capsule,filled with earth enhancing compound,sealed at both ends and brazed lead for connection at one end suitable for direct installation at site at a depth of 2.5 mtr.Earth enhancing compound upto a depth of 2.0 mtr around the electrode capsule and also wih brick chamber and cast Iron cover etc complete including excavation in all types of soil.

2

27680

13840

... More
Supply and laying of following size strips including all necessary inter connections with earth station and equipments.

-

-

-

... More
a) 50 X 5 mm Hot dip GI strip

50

17350

347

... More
b) 25 X 5 mm Hot dip GI strip

5

1060

212

... More
Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.

300

15000

50

... More
Supply and fixing of following size GI Perforated type cable tray made out of 2mm thick G.I sheet including MS supports for fixing the tray, anchor fasteners etc., laid including 2runs of 25x5 GI strip etc including with 2 mm thick GI covers. a) 100 mm wide x 50 mm Height

10

7730

773

... More
Supply, laying, jointing GI pipes of medium quality including specials of approved make fixed to wall/to the required lengths, threading jointing chasing the walls and floor, making holes, clamping of clamps and making good the same, necessary excavation, etc., complete as specifed and directed. a) 50mm Dia

5

3080

616

... More
SUBHEAD-XI : UPS WIRING :

-

-

-

... More
Supply and fixing of 2 Nos of 6/16A, 5Pin Socket outlet with 2Nos of switch of 16A rating including Modular G.I Box, Front Plate and also including all fixing accessories etc complete. ( For UPS Socket)

20

31540

1577

... More
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required a) 125 A, 16 KA,TPMCCB

1

7482

7482

... More
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) a) 4 way (4 + 12), Double door

1

12563

12563

... More
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator). a) 4 way (4 + 12), Double door

1

5314

5314

... More
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.

-

-

-

... More
a) 40 A

2

12348

6174

... More
b) 63 A

2

13568

6784

... More
Supplying and fixing of 6A to 32A rating 240/415V, 10kA, C Curve miniature circuit breaker suitable for inductive load of following polesin the existing MCB DB complete with connections, testing and commissioning etc complete. a) Single Pole

24

8616

359

... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.

-

-

-

... More
a) 2 X 4 sq. mm + 1 X 4 sq. mm earth wire

500

184000

368

... More
b) 4 X 10 sq. mm + 2 X 6 sq. mm earth wire

100

99600

996

... More
c) 4 X 16 sq. mm + 2 X 6 sq. mm earth wire

50

70500

1410

... More
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required including excavation in all types of soil.

2

26320

13160

... More
Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets(Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm).

120

94800

790

... More
SUBHEAD-XII : EXTERNAL ELECRIFICATION

-

-

-

... More
11 kv INDOOR VCB PANEL Supply,Installation,Testing and commissioning of the following indoor floor mounted 11 kv Rated VCB Panel in Metal Enclosure fabricated out of 14 swg sheet steel to be operated on 11KV,Three phase,50HZ A.C Power supply .The panel is to be compartmentalised with individual compartments for Bus bars, Cable and CTs and Instrument and relay control Panel. The VCB shall be horizontal draw out single break as per IS 13118.The short circuit fault level of the system shall be 350MVA. 11 KV VCB panel with one no of 800 A vcb -Indoor at Tapping Point.

-

-

-

... More
11 KV H.T Switch Gear Panel (INDOOR TYPE) With 1 No. OF 800 A Vaccum Circuir breaker as Outgoing. CONSTRUCTION - The Switch Gear Panel shall be compartmentalised Designed with cubicles fabricated out of High Quality Sheet Steel . The panels shall be designed having the Following Segregations separately. a) Busbar compartment b) Cable and CT compartment c) Instrument and Relay Compartment The clearances between phase to phase and phase to earth shall be provided in accordance with the relevant standards. The bus bars shall be supported by bus support insulators placed at regular intervals. The panels shall be powder coated with epoxy base paint to give an aesthetically pleasing appearance. The paint shade shall be as per the requirement. SAFETY FEATURES: a) Mechanical Interlock and earth switch for out goings b) Door interlock in service position. OUTGOING VCB PANEL 11 , KV, 800A, 26.2 KA, Horizontal Draw out type Vaccum Circuit breaker with motor/manual spring charge mechanism and also with mechanical indications for breaker on /off/trip indications and also with Local Remote selector switch and with breaker TNC Switch.

1

746457

746457

... More
CURRENT TRANSFORMER: (3 No’s) Cast Resin Ratio 100-50 - 5/5 A , Core 1: 15 VA, CI – 0.2 for Metering and 5P10 for protection. METERING: ( 1set) 96 Sq.mm Digital Ammeter with selector switch Digital type 0-100A. Digital Multi function Meter for KW,KWH,KVA, KVAR , COS PHI Parameters reading. INDICATION LAMPS: 1) TCH, Battery failure , Spring charge, discharge, ON, OFF and Trip Indication Lamps, Phase indication Lamps for RYB. - (1 set) CONTROL SWITCHES/PUSH BUTTON Bus Bar with 800 Amps Copper - (1 set) COMMON FOR SWITCHGEAR: Heater ON and OFF Switch with Space heater, single Phase switch socket and cubicle lamp for panel illumination, MCB's for AC/DC Control - (1 set) MS sheet enclosure suitable for Indoor installation with outgoing cable entry. - (1 set) Relays Incomer ; Undervoltage relays 2 nos,IDMT relay ,TCH and Master trip relay and also with 12 window annunciator The scope includes the extension of busbars in the existing panel and coupling of these busbars to the new switchgear vcb panel including earth connection. Power Pack - 1 No with necessary Interconnections.

-

-

-

... More
11KV H.T Switch Gear Panel (OUTDOOR TYPE) 1No. OF LBS Incomer / Outgoing LBS feeder CONSTRUCTION - The Switch Gear Panel shall be compartmentalised Designed with cubicles frabicated out of High Quality Sheet Steel and the panels shall be dust and vermin proof and with degree of protection IP 55 as per IS 2147. The panels shall be designed having the Following Segregations separately. a) LBS compartment b) Busbar compartment c) Cable and CT compartment d) Instrument and Relay Compartment The clearances between phase to phase and phase to earth shall be provided in accordance with the relevant standards. The bus bars shall be supported by bus support insulators placed at regular intervals. The panels shall be powder coated with epoxy base paint to give an aesthetically pleasing appearance. The paint shade shall be as per the requirement. SAFETY FEATURES: a)Door safety Interlock b) Earthing through a draw-out earthing truck with solid links on the bus bar and feeder side to be provided. c) Integral earthing switch, slow closing type or with making capacity to be provided. INCOMING/OUTGOING LBS FEEDER (1 No) Each Consisting of 11KV, 630A, 13.1KA, 30A fuse unit Horizontal Draw out type LOAD BREAK SWITCH UNIT Manually Operated With 4No+4Nc, Mechanical ON and OFF indicator and Push button, Mechanical operation counters with all other accessories as per the requirement.

1

559843

559843

... More
POTENTIAL TRANSFORMER: (1No) Cast resin PT with HT and LT HRC Fuses, Ratio: 11KV/110V+ Three Phase, Burden 100 VA, Acc.CI 0.2. CURRENT TRANSFORMER: (3 No’s) Ratio 50-5A Core 1:20VA, CI – 0.2 for Metering. METERING: ( 1set) 96 Sq.mm Digital Ammeter with selector switch Digital type 0-50A. 96 Sq.mm Digital Voltmeter with selector switch Digital voltmeter 0-36KV. INDICATION LAMPS: 1) ON, OFF and Trip Indication Lamps for RYB. - (1 set) CONTROL SWITCHES/PUSH BUTTON Bus Bar with 800 Amps Aluminium (Electrical Grade). - (1 set) COMMON FOR SWITCHGEAR: Heater ON and OFF Switch with Space heater, single Phase switch socket and cubicle lamp for panel illumination, MCB's for AC/DC Control - (1 set)

-

-

-

... More
Supply and commissioning of 11 KV earthed HT cable of size 3 c x 185 sqmm XLPE insulated armoured alluminium conductor cable as per IS 7098 - Part 2 - 1983

100

130700

1307

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. a) Above 120 sq. mm and upto 400 sq. mm

80

29520

369

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. a) Above 120 sq. mm and upto 400 sq. mm

10

2390

239

... More
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size on cable tray as required. a) Above 120 sq. mm and upto 400 sq. mm

10

2220

222

... More
Supply, Installation, Testing and commissioning of 11 KV earthed heat shrinkable end termination kit of 11 KV earthed XLPE insulated armoured alluminium conductor HT Cable of size 3 c x 185 sqmm ( Indoor Termination Kit).

2

40546

20273

... More
Supply and Installation ,Commissioning of HT Straight through Joint Kit for 3 C x 185 Sqmm Earthed XLPE insulated armoured alluminium conductor cable.

1

39204

39204

... More
Supply, Installation, Testing and commissioning of 400 KVA, 11kv / 433 v, 3 PHASE, 50 Hz, Dyn 11 OUTDOOR ONAN Transformer with off load tap changer and HT Side marshalling box for termination of 11 kv grade , 3 c x 185 sqmm XLPE insulated alluminium conductor screeened cable and LT side provision for marshalling box for connecting 3 Runs of 3.5c x 240 Sqmm XLPE insulated armoured alluminium conductor cable as per IS 1180 ( Level 2 ) with radiators etc

1

1991691

1991691

... More
M.V.PANELS Supply, installation, Testing and Commissioning of 3 phase and Neutral 415V, 4 wire , Free Standing Floor mounted MVpanel made out of 14 SWG MS sheet after seven tankprocess and painting with Epoxy powder coating. The panel shall consist of suitable rating TPN Aluminium busbar (at the rating of 0.8A/Sq.mm) supported with DMC/ SMC barriers and color coded with Heat shrinkable sleeves.The Metering shall be provided as specified. The panel shall have Short circuit withstanding capacity of minimum 50 KA and consist of the switchgear as mentioned below. The panel shall be got fabricated from manufacturers with CPRI Test certificate only. . The size of all Panel Mounting Meters shall be 96X96mm. The Panels shall be mounted on U channels including supply and fixing of the same. Every ACB shall be provided with TNC Switch,ON/OFF /TRIP/TCH, Indication lamps of LED type. For all Electrically operated Breakers,Local Remote Selector switches shall beprovided for controlling the Breakers remotely.

-

-

-

... More
MAIN LT PANEL - 1 - Indoor Incomer 1 : 1 No of 800 A, 4P. EDO ACB, 50KA, shall be supplied with S/C,E/F,O/C AND INSTANTANEOUS TRIP RELAY UNIS WITH TIME DELAY SETTINGS. 2A, control fuse - 3 Nos. RYB indicating lamps - 1 set Voltmeter (0-500V) with selector switch - 2 set Ammeter (0-800A) with selector switch - 2 set 800/5A, CL-1, 15VA CT's with resin cast- 3 nos. A Single CT with ratio of 800 / 5 A , 15 VA, 5 P 10 ,CT for feeding APFC relay of APFC panel. Outgoing a) 800A, 3P, 50KA, ACB, - = 2 No b) 200A, 3P, 35KA, MCCB, - = 2No c) 63A, 3P, 16KA, MCCB, - = 3No d) 40A, 3P, 16KA, MCCB, - = 2No e) 63 A, 3P, 16KA, MCCB, - = 1 No and also with 20 A SPMCB as outgoings 3 Nos with timer circuit for controlling of street lights and the timer should be with required 24 hors clock settings. Bus Bars : 800A, 3Ph, 4 wire TPN, 50Hz, aluminium bus bars Metering Instruments ; Load Manager in the Incomer and ACB/ MCCB on , off , Trip Indication Lamps and with Breaker Status indication Lamps and also with Phase indication Lamps. Earth Bus; To be provided at the bottom of the Panel of gi Strip

1

425512

425512

... More
APFC PANEL – Indoor Supply, Installation, Testing and Commissioning of APFC PANEL with Automatic power factor control relay and with 5 nos of 20 kvar capacitor banks and 10 kvar capacitor banks 1 nos and 2 Nos 5KVAR with the following incoming and out goings.. The Panel is to be installed in Indoor. The panel is to be supplied with necessary power and control wiring required for the automatic operation of Power factor control.

-

-

-

... More
APFC PANEL – Indoor INCOMER 200 A, 4 P , MCCB with O/c, S/c,E/f Protection Microprocessore Relay Unit 2A, control fuse - 3 Nos. RYB indicating lamps - 1 set Voltmeter (0-500V) with selector switch - 1 set Ammeter (0-200A) with selector switch - 1 set 200/5A, CL-1, 15VA CT's with resin cast- 3 nos. Outgoing 63 A, 3P, SDF , - 7 No Bus Bars : 200A, 3Ph, TPN, 50Hz, aluminium bus bars Metering Instruments ; Multi Function Meter in the Incomer and SDF on , off , TRIP Indication Lamps and with Breaker Status indication Lamps and also with Phase indication Lamps Earth Bus; To be provided at the bottom of the Panel of copper The panel is to be supplied with Required capacity Capacitor Banks as per BOQ quantity and also with required capacity over load relays,contactors ,Switch disconnecting fuses and also with APFC relay control wiring for manual and Auto operation.The Panel Shall be provided with 12 Stage APFC Relay Panel with 2 nos Spare Compartments.

1

214995

214995

... More
Supply,Installation,Testing and commissioning of 630A,440V Three Phase and Neutral Switch Fuse Unit in MS Powder coated painted enclosure including 630A HRC Fuses and also including all fixing accessories etc complete.

1

21340

21340

... More
Supply, installation, testing and commissioning of 3 phase 415V 4 wire Free Standing Floor mounted Outdoor MV panels made out of 14 SWG MS Sheet after seven tank process and painting with epoxy powder coating including all switchgear as detailed below. This panel shall consist of suitable rating TPN aluminium bus bar (at the rating of 0.8A/ Sqmm) supported with DMC/ SMC barriers and color coded with heat shrinkable sleeves. The metering shall be provided as specified. This panel shall have short circuit withstanding capacity of minimum 50 KA and consist of the switchgear as mentioned below. This panel shall be mounted on channels including supply of the same. This panel shall be got fabricated from manufacturers with CPRI test certificate only. This panel shall have at least two spare cubicles of maximum ratings. The size of all panel mounting meters shall be 96 x 96 mm. The panels shall be mounted on U channels including supply and fixing of the same. Every MCCB shall be provided with ON/OFF /Trip Indication lamps of LED type. For all Electrically operated Breakers, Local Remote Selector switches shall be provided for controlling the Breakers remotely.

-

-

-

... More
MAIN PANEL COMPRESSOR ROOM INDOOR 800A,50KA 4P ,EDO ACB with O/C, S/C,E/L Micro process Based Release – 1 No Busbars : 800A TP+N Aluminum Bus bar – 1 Set EB Meterings : 0-500V Digital Voltmeter with selector switch and MCB control- 1set 0-800A Digital Ammeter with resin cast CTs of ratio 800/5A Class 0.5Accuracy and 15VA burden with selector switch -1 sets LED Phase indication lamps with individuals MCBs and control with toggle switches with MFM meter- 1 set A Single CT with RAtion 800A/5A Class 0.5Accuracy and Burder 15VA Outgoings : 630A,50KA ,TPN ACB (EDO) with ON, OFF, TRIP LAMPS– 2 Nos ( 1 Spare Included) 63A,16KA TPN MCCB with ON, OFF, TRIP LAMPS– 2 NoS

1

597210

597210

... More
1.1KV Cables: Supply of following size 1.1KVgrade XLPE insulated armoured aluminium / Copper conductor cable. The cable shall conform to IS 7098.

-

-

-

... More
a) 3.5C X 300 Sq.mm AR.Aluminium

850

1271600

1496

... More
b) 3.5C X 25 Sq.mm AR.Aluminium

100

20200

202

... More
END TERMINATIONS: Supply, laying and commissioning of Out Door /Indoor, Double compression / ordinary end terminations for the cable specified below with compression type steel gland,Bi-metallic lugs using crimping tool,Insulation tape,Identification tags etc., including end termination.

-

-

-

... More
a) 3.5C X 300 Sq.mm AR.Aluminium

12

13752

1146

... More
b) 3.5C X 25 Sq.mm AR.Aluminium

4

1160

290

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.

-

-

-

... More
a) Upto 35 Sqmm

50

17900

358

... More
b) Above 185 sq. mm and upto 400 sq. mm

750

318750

425

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as require

-

-

-

... More
a) Upto 35 Sqmm

50

1600

32

... More
b) Above 185 sq. mm and upto 400 sq. mm

100

4700

47

... More
SUBHEAD-XIII : AREA LIGHTING

-

-

-

... More
Supply and erection of 65 mm Dia, Class B GI Pipe of 3 mtr. long with base plate, earthing studs, 3 phase and neutral loop-in and loop-out box as per specifications, 2nos 50mm dia,1.5mtr. long GI bent pipes for incoming and outgoing cables, including excavation , 1 :2 : 4 PCC Pedestal etc complete. The pole shall be with Junction box consisting of MCB. The Junction box shall be of weather proof. The wiring from Junction box to Light fixture shall be carried out with 3core 2.5sq.mm flexible copper conductor cable. The Pole shall be fixed with weather proof 72W LED ( Philips Cat No :BRP046 LED 30 CW MR S1 PSU GR/equivalent) Light fixture including supply of driver and fixing clamps etc complete.

6

47448

7908

... More
Supply, testing and commissioning of following size 1.1KV grade XLPE insulated armoured aluminium conductor underground cable. The cable shall conform to IS 7098/ Part-II. a) 4Core 10sq.mm

250

30000

120

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required a) Upto 35 Sqmm

150

53700

358

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. a) Upto 35 Sqmm

100

3000

30

... More
Providing End terminations for the following size of 1.1 KV grade XLPE insulated armoured alluminium conductor cable with compression type steel gland, alluminum lugs using crimping tool, Insulation tape, Identification tags etc.,complete a) 4Core 10 sq.mm

12

3180

265

... More
Providing Spiral coil earthing with 8 SWG GI wire including spreading of salt and charcoal as per IS 3043/87 with latest amendments.

6

14352

2392

... More
SUBHEAD-XIV : ROADS/HARDSTANDING

-

-

-

... More
Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earthwith lead upto 50 metres.

600

90600

151

... More
Banking excavated earth in layers not exceeding 20 cm in depth, breaking clods, watering, rolling each layer with ½ tonne roller, or wooden or steel rammers, and rolling every 3rd and top-most layer with power roller of minimum 8 tonnes and dressing up, in embankments for roads, flood banks, marginal banks, and guide banks etc., lead upto 50 m and lift upto 1.5 m in all kinds of soils.

400

164800

412

... More
Providing, laying, spreading and compacting graded stone aggregate (size range 53 mm to 0.075 mm ) to wet mix macadam (WMM) specification including premixing the material with water at OMC in for all leads & lifts, laying in uniform layers with mechanical paverfinisher in sub- base / base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achievethe desired density, complete as per specifications and directions of Engineer-in-Charge.

120

475320

3961

... More
Providing and laying Bituminous concrete using crushed stone aggregates of specified grading, premixed with bituminous binder and filler, transporting the hot mix to work site by tippers, laying with paver finisher equiped with electronic sensor to the required grade, level and alignment and rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction and density as per specification, complete and as per directions of Engineer-in-Charge. a) 40/50 mm compacted thickness with bitumen of grade VG-30 @ 5.5% (percentage by weight of total mix) and lime filler @ 3% (percentage by weight of Aggregate) prepared in Batch Type Hot Mix Plant of 100-120 TPH capacity.

30

328680

10956

... More
Providing and applying tack coat using bitumen emulsion conforming to IS:8887, using emulsion pressure distributer including preparing the surface & cleaning with mechanical broom.With rapid setting bitumen emulsion. On W.B.M / W.M.M. @ 0.4kg/Sqm.

600

12000

20

... More
Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge).

9

85725

9525

... More
Dry stone pitching 22.5 cm thick laid in courses and required profile with hammer dressed stones having no side less than 15 cm, with minimum depth of 20 cm including preparing the bedding surface etc. all complete.

15

3990

266

... More
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc., complete.

-

-

-

... More
a) 150 mm dia. R.C.C. pipe

20

15940

797

... More
b) 300 mm dia. R.C.C. pipe

30

35610

1187

... More
c) 450 mm dia. R.C.C. pipe

10

20030

2003



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.