Zilla Parishad Tender

... More
The ZP has issued a formal invitation for competitive bids for the Zilla Parishad project, for Instalation Of Solar Drinking Water System At Kuchila Health Sub Center, Activity Code No.- 145159837/ 26-27 in South Dinajpur, West Bengal, with an estimated contract value of Rs. 3,49,501. The bid opening date for this tender is 06-11-2026 and the last date for bid submission is 19-11-2026. Interested bidders for Zilla Parishad tender can download the important documents here to check the scope of work, eligibility criteria and technical requirements.

Zilla Parishad - ZP Tender - WB Tender

Opening Date6 Nov 2026
Closing Soon19 Nov 2026
Tender Amount₹ 3,49,501 
Notes
Download

Costs

Description

Instalation Of Solar Drinking Water System At Kuchila Health Sub Center, Activity Code No.- 145159837/ 26-27

Contact

Unlock the Tender details

GEM & Bid Advisory Services

Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

Unlock the Tender details
... More
1:1.5:3 (1 Cement : 1.5 Coarse sand (zone - III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)

1.39

8340

11593.78

... More
Making plinth protection 50 mm thick of cement concrete 1:3:6 ( 1 cment : 3 coarse sand (zone - III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75 mm thick bed of dry brick ballast 40 mm nominal size well rammed and consolidated and grouted with fine sand including necessary excavation, levelling & dressing & finishing the top smooth

7.02

749

5260.09

... More
STEEL REINFORCEMENT Steel reinforcement for RCC work including straightening, cutting, bending, placing in position and binding all complete upto plinth level

63.024

107

6797.14

... More
Brick work with common burnt clay F.P.S (non modular) bricks of class designation 7.5 in foundation and plinth in

2.78

7132

19827.66

... More
Providing and laying Ceramic glazed floor tiles of size 300X300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivgory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg / sqm including pointing the joints with white cement and matching pigment etc. complete

5

1096

5482.75

... More
20 mm cement plaster of mix :

21.63

466

10080.66

... More
Providing and fixing MS grill of required pattern in frame of windows etc with MS flats, square or round bar etc including priming cost with approved steel primer all complete Fixed to openings / wooden frames with raw / plugs screws etc

213.6

238

50911.56

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply and all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.

25

401

10038.75

... More
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.

1000

11

11000

... More
Constructing soak pit 1.20x1.20x1.20 m filled with brick bats including S.W. drain pipe 100 mm diameter and 1.20 m long complete as per standard design

1

4500

4500

... More
Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 90 metre depth below ground level. 23.1.1 All types of soil 23.1.1.1 300 mm dia

48

707

33972

... More
Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. 23.3.1 100 mm nominal size dia

48

672

32270.4

... More
Solar Module : Supply, transport, installation and commissioning of ISI marked Solar Modules as per following specification : 1. Cell indegenous mono crystaline silicon SPV cells 2. Solar Module : Monocrystaline cell with PERC technology module with bifacial and TOPCon cell. 3. Standards : ISI marked as per IS 14286 and having certification of IEC : 61853(1), 61730 (1&2), 61710. 4. Modules must qualify to IS 170210 (Part 1). 5. Min Efficiency : 19.5%. 6. Fill factor : More than 75%. 7. Module wattage mismatch in the SPV array : within +- 3%. 8. Wattage output warranty. Should not be less than 90% at the end of 10 years and 80% at the end of 25 years. 9. The power output of individual PV modules used in the PV array under STC: minimum 300 Wp. Necessary test certificates also to be supplied. For 1 HP Off grid Solar Water Pumping System with Monocrystalline PERC bifacial SPV modules 900 - 1200 Wp

1080

38

41493.6

... More
Power conditioning unit with enclosure : Suppty , transport , installation and commissioning of Solar Power conditionang unit consisting of following components and features 1) Variable ,frequency Drive with inbuilt MPPT, voltage range suitable for operating pump motor set of IHP to 20 HP, detail mentioned in Cl-6.1 2) Power input: DC source for.lHP, 2HP and 3HP. 3) Power input : AC/ DC source or hybid for 5HP and above. 4) lncomer: DC MCB 2 Pole 16 amp upto 5 HP, 25 amp for 7.5HP and 10 HP, 40 amp for 15 to 20 HP as per lS/lEC 60947-2 5) lncomer: AC MCB 4 pole 16 amp for 5 0 HP, 25 amp for 7.5HP a.d 10 HP, 40 amp for 15 to 20 HP as per lS/lEC 60947-2 6) Type ll DC SPD of 40 KA. 7) Type llAC SPD of 40 KA for AC/ DC or Hybrid input. 8) Dual input (solar/Grid) 25 amp changeover switch for 5HP and 7.5 HP, 40 amp for 10 HP, 63 amp for 15 to 20 HP 9) Reverse protection diode 1600 VDC with heal sink. 10) Data Logger. 11) Remote monitoring syslem 12) Should have bualt -in EMC fillers . 131 1P 65 elands for cable in and out 14) Min. lP 54 enclosure. For delail features, proteclions, RMS, Communication architecture, Security, Data storage, tolerance of various parameters, standatds to be qualifed, etc. For 1 HP capacity Pump motor set with DC input

1

22676

22676.64

... More
Three phase openwell lsl Marked submersible pumpset of 1.5H.P. capacrty suitable ror operation on 415V(+-107o), 3- phase AC/DC supply complete as required.

1

19821

19821

... More
Earthing with G.l. earth pipe 4.5 Meter long, 40 mm dia including accessories, and providing masonry enclosure wth cover plate having locking araangement and watering pipe etc (but wilhout charcoal/ coke and salt) as required.

1

5958

5958

... More
Supplying and laying 6 SWG G.l. wire at 0.50 Meter below ground level for conductor earth elecrode, including connection/ teminalion with Gl thimble etc. as required.

3

62

186

... More
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutling lhe wall and makang good the same in case of recessed conduit as required 20 mm

12

151

1812

... More
Cable and Accessories : Supplying, fitting and fixings of UV rated Copper Cable laid inside HDPE conduit and other accessones as per followings with necessary connectjon with the Solar PV Module, MPPT etc. i. 4.0 Sq mm single core multi studs - Sm(for 1HP/2HPI3HP) & 20m(for s/7 .5/10/15/,17.5/20 HP) ii. Lugs, HDPE Pipe, Flexible Pipe, Saddle, Cable tie etc a) For 1 HP/2HP/3HP per structure

1

1349

1349.46

... More
Add Escalation for Cost Index

1

40763

40763.25



Evaluation Notes How It Works ?

Related Tenders

Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.