Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.
West Bengal Financial Corporation Tender
Civil And Construction
Fire and Safety Equipments
Security and Emergency Services
Eprocure
Opening Date24 Aug 2023
Closing Date12 Sep 2023
Tender Amount₹ 6,06,000 This is an estimated amount, exact amount may vary.
Costs
EMD
₹ 16,685Document Cost
Refer DocumentsTender Fee
Refer Documents
Summary
Fire System Renovation
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2023_WBFC_559939_1Bid Award Id
ViewTender No
MD/WBFC/FSRW/01 of 2023-24Tender Authority
West Bengal Financial Corporation ViewPurchaser Address
-Website
http://www.mstcindia.co.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Supply, Installation,Testing & Commisioning of Addressable Manual Call Point ( VDS / UL /ERTL/ LPCB / FM approved ) with in built short circuit fault isolator as per NFPA style 7 wiring complete as required.
(Approved Make: Honeywell- Esser)
3
-
-
... More
Supply, Installation, Testing & Commissioning of Addressable Loop Powered Hooter ( sound output of minimum 90 db ) cum strobe (strength of light 10 cd) complete with inbuilt short circuit fault isolator. Degree of protection IP65 ( VDS / UL /ERTL/ LPCB / FM approved) approved. (Approved Make: Honeywell- Esser)
3
-
-
... More
Supply and Laying of 2c x 1.5 sq.mm FRLS shielded Cooper cable (For Loop) through with 20 mm PVC FR type Rigid conduit pipe with necessary arrangements as per G.S.
(Make: Finolex/ Polycab/RR)
300
-
-
... More
Checking & Servicing of Fire Pumps including electrical motors and diesel engine inside Fire Water Pump House and recommisioning of the same as per system requirement complete in all respect
-
-
-
... More
Electrical Motor Driven Horizontal centrifugal type Main Fire Pump with 60 H P Compton Greaves make Induction motor with all accessories / fittings
1
-
-
... More
Kirlosker 85 H P. Diesel Engine Driven Stand-By Pump with Engine with all accessories / fittings with supply of lubricant, coolant, oil & disel filter and diesel in the fuel tank
1
-
-
... More
Elecrical Motor Driven horizontal centrifugal type Jockey Pump with 12.5 H P Cormpton Greaves make Induction motor with all accessories / fittings
1
-
-
... More
Checking & Servicing of Composite Motor Control Center (MCC) for manual / automatic Operation / control of two elctrical motor diriven Fire Pumps & one Diesel Engine run fire pump Including replacement of Damaged/ Defective parts [ if found during checking] complete in all respect as per system requirement along with supply & installation of electronic battery charger for boost / tricle charging facility of the engine battery in the existing MCC cubicle & new battery for engine as per system requirement separately to be quoted as under
1
-
-
... More
Checking & Servicing of Composite Motor Control Center (MCC) for manual / automatic Operation / control of two elctrical motor diriven Fire Pumps & one Diesel Engine run fire pump Including replacement of Damaged/ Defective parts [ if found during checking] complete in all respect as per system requirement along with supply & installation of electronic battery charger for boost / tricle charging facility of the engine battery in the existing MCC cubicle & new battery for engine as per system requirement separately to be quoted as under
1
-
-
... More
Supply,instalaltion & commssioning of new Exide make battery 12 volt, 150 AH with fitting clamps compatiable for existing Diesel Engine
-
-
-
... More
Supply, instalaltion & commisioning of new electronic battery charger with auto / maual boost / trickle charging facility for new battery for Diesel Engine to be installed in existing MCC cubicle
-
-
-
... More
Checking, Cleaning, Servicing and repainting of Valves Including replacement of Gland Packing with repair of valve, if found necessary, complete in all respect
-
-
-
... More
CI Sluice Valve
-
-
-
... More
150NB CI Sluice Valve, NRS, IS: 14846, PN: 1.6
4
-
-
... More
100NB CI Sluice Valve, NRS, IS: 14846, PN: 1.6
2
-
-
... More
80NB CI Sluice Valve, NRS, IS: 14846, PN: 1.6
1
-
-
... More
50NB( one nos valve may be replace for priming line)
5
-
-
... More
CI Non-Return Valve
-
-
-
... More
150NB CI Non-Return Valve, IS: 5312,
2
-
-
... More
100NB CI Non-Return Valve, IS: 5312,
1
-
-
... More
50NB( one nos valve may be replace for priming line)
4
-
-
... More
CI Foot Valve
-
-
-
... More
200NB CI Foot Valve, IS: 4048,
2
-
-
... More
80NB CI Foot Valve, IS: 4048,
1
-
-
... More
Cleaning and Servicing of Fire Hydrant with Accessories complete in all respect
-
-
-
... More
Yard Hydrant Valves, IS: 5290, Type-A,
4
-
-
... More
Internal Landing Valves, IS: 5290, Type-A,
6
-
-
... More
External Hose Box (750 x 600 x 250) with painting as necessary
4
-
-
... More
Internal Hose Box (600 x 600 x 250)
6
-
-
... More
External / Internal 15 mtr long RRL Hose, Type-A, Hose with Coupling & binding, IS: 636 & IS: 903
14
-
-
... More
External / Internal Branch Pipe with Nozzle, IS: 903,
10
-
-
... More
Internal Hose Reel 20 mm dia x 30 m long with Shut Off Nozzle conforming IS: 884,
6
-
-
... More
Supply and instalaltion of new nozzle for hose(s)
2
-
-
... More
3 way Fire Brigade Inlet connection IS: 904,
1
-
-
... More
Cleaning and Checking of Pressure Switch including necessary adjustment of Pressure Switch for Automatic operation of Fire Pumps complete in all respect
-
-
-
... More
Motor Driven Main Pump
1
-
-
... More
Engine Driven Stand-By Pump
1
-
-
... More
Motor Driven Jockey Pump
1
-
-
... More
Checking with calibration of Pressure Gauges (100mm dia) inside / outside Fire Water Pump House complete in all respect
5
-
-
... More
Checking & cleaning with Leakage repair (if any) and repainting of eitire fire water header, Pipe Line and wet riser for Fire Control System
1
-
-
... More
Sprinkler system
-
-
-
... More
Checking of all existing sprinklers with accessories in 5th floor complete in all respect with repair if necessary
1
-
-
... More
Supply / Re-Filling of Portable Fire Extinguishers
-
-
-
... More
Refilling of Stored Pressure ABC type Dry Chemical Powder of 5 kg capacity as per IS: 15683
21
-
-
... More
Refilling ABC type Dry Chemical Powder of 4 kg capacity as per IS: 15683
8
-
-
... More
Refilling of 4.5 kg capacity Carbon di Oxide Extinguishers as per IS: 15683
9
-
-
... More
Refilling of 9L capacity Water CO2 Extinguishers as per IS: 15683
10
-
-
... More
Supply of 9 L Foam Type Extingusher as per IS: 15683
1
-
-
... More
Supply & installtion of the following
-
-
-
... More
Electrical Rubber insulation Mat – 11KV (1 Mtr x 2 Mtr, 2.5mm Thickness) Anti – Skid/Shock Proof/ISI Certified
2
-
-
... More
Signage Sticker
-
-
-
... More
"Danger"
2
-
-
... More
"Don't use Lift during Fire"
6
-
-
... More
"Fire Exit →"
5
-
-
... More
"Fire Exit ↘"
5
-
-
... More
Checking of All Electrical Wiring including Earth Pits and necessary Rectification,if any
1
-
-