West Bengal Financial Corporation Tender

... More
Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.

West Bengal Financial Corporation Tender

Works
Civil And Construction
Security and Emergency Services
Eprocure
Opening Date24 Aug 2023
Closing Date12 Sep 2023
Tender Amount₹ 6,06,000 
This is an estimated amount, exact amount may vary.
Notes
Download

Costs

Summary

Fire System Renovation

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Refilling of 4.5 kg capacity Carbon di Oxide Extinguishers as per IS: 15683

9

-

-

... More
Checking & Servicing of Composite Motor Control Center (MCC) for manual / automatic Operation / control of two elctrical motor diriven Fire Pumps & one Diesel Engine run fire pump Including replacement of Damaged/ Defective parts [ if found during checking] complete in all respect as per system requirement along with supply & installation of electronic battery charger for boost / tricle charging facility of the engine battery in the existing MCC cubicle & new battery for engine as per system requirement separately to be quoted as under

1

-

-

... More
Cleaning and Servicing of Fire Hydrant with Accessories complete in all respect

-

-

-

... More
Signage Sticker

-

-

-

... More
Elecrical Motor Driven horizontal centrifugal type Jockey Pump with 12.5 H P Cormpton Greaves make Induction motor with all accessories / fittings

1

-

-

... More
Electrical Rubber insulation Mat – 11KV (1 Mtr x 2 Mtr, 2.5mm Thickness) Anti – Skid/Shock Proof/ISI Certified

2

-

-

... More
Motor Driven Main Pump

1

-

-

... More
3 way Fire Brigade Inlet connection IS: 904,

1

-

-

... More
"Fire Exit ↘"

5

-

-

... More
Supply of 9 L Foam Type Extingusher as per IS: 15683

1

-

-

... More
External / Internal Branch Pipe with Nozzle, IS: 903,

10

-

-

... More
External Hose Box (750 x 600 x 250) with painting as necessary

4

-

-

... More
Sprinkler system

-

-

-

... More
Cleaning and Checking of Pressure Switch including necessary adjustment of Pressure Switch for Automatic operation of Fire Pumps complete in all respect

-

-

-

... More
Supply / Re-Filling of Portable Fire Extinguishers

-

-

-

... More
Internal Hose Box (600 x 600 x 250)

6

-

-

... More
Supply and instalaltion of new nozzle for hose(s)

2

-

-

... More
Checking & Servicing of Composite Motor Control Center (MCC) for manual / automatic Operation / control of two elctrical motor diriven Fire Pumps & one Diesel Engine run fire pump Including replacement of Damaged/ Defective parts [ if found during checking] complete in all respect as per system requirement along with supply & installation of electronic battery charger for boost / tricle charging facility of the engine battery in the existing MCC cubicle & new battery for engine as per system requirement separately to be quoted as under

1

-

-

... More
Supply, Installation,Testing & Commisioning of Micropresssor controlled Addressable Multisensor detector IP 54 ( VDS / UL /ERTL/ LPCB / FM approved ) with inbuilt optical smoke sensors and heat detector sensor with inbuilt short circuit fault isolator as per NFPA style 7 wiring complete with base (Note : Detectors without built-in fault isolator is also acceptable provided one independent short circuit fault isolator per detector is to be provided extra without extra cost) the detectors should have built in response indicator with LED indicator. The detector should have 360 degree optical view with single / multiple LED that blinks on actuation of detector. Reverse polarity or faulty zone wiring shall not damage the detectors. (Approved Make: Honeywell- Esser)

37

-

-

... More
Checking of all existing sprinklers with accessories in 5th floor complete in all respect with repair if necessary

1

-

-

... More
"Danger"

2

-

-

... More
CI Sluice Valve

-

-

-

... More
External / Internal 15 mtr long RRL Hose, Type-A, Hose with Coupling & binding, IS: 636 & IS: 903

14

-

-

... More
Engine Driven Stand-By Pump

1

-

-

... More
Checking with calibration of Pressure Gauges (100mm dia) inside / outside Fire Water Pump House complete in all respect

5

-

-

... More
Internal Landing Valves, IS: 5290, Type-A,

6

-

-

... More
Supply, Installation, Testing & Commisioning of Microprocessor based addressable fully networkable fire alarm control panel ( VDS / UL / ERTL/ LPCB / FM approved ) suitable for the devices as stated in the items of this BOQ and existing 96 nos. (honeywell make)addressable Multi Crateria Detectors, 10 nos. Manual Call Points and 10 nos. Hooters along with 20% spare capacity with each loop loading not exceeding 80% of the full capacity of detectors and devices taken together, conplying to IS 2189:2008 or its latest amendments, and with minimum 600 character alpha - numeric liquid crystal display. The Panel should able to take care of existing 96 nos. addressable Multi Crateria Detectors and able to detect and communicate with them along with 37 (Approx.) nos. of new Detectors (as mentioned in this BOQ Sl.No.1.02) and existing Manual Call Point and Hooter and additional items (as Mentioned in this BOQ Sl. No.1.03 and 1.04). The panel shall be soft addressable type and shall be able to give pin point location of all fire/ fault conditions. Further, the panel must be able to automatically switch off respective control switches with help monitor module whenever any alarm is triggered. The Panel should be able to store sufficient numbers of log events in its Memory as per recommended standards. The panel shall have in built rectifier, provision for external & internal printer ( if required ), Loop cards, L C D unit to indicate Fire/Fault Signal with address and analog output, complete in all respects, in built Surge protection facility, integral SMF lead acid batteries with sealed cells of 24 V capable of running for 24 hours normal working and then be capable of operating the system for 60 minutes during Emergency condition, with integral battery charger complete in all respect as required. The FACP shall be capable of being networked ( future expansion ) with other similar FACP located at different part of the premises through single RS 485 modbus. The FACP shall have provision for interfacing with the public address system, remote computer. The system must be preloaded with licenced software. (Approved Make : Honeywell Esser)

1

-

-

... More
Supply,instalaltion & commssioning of new Exide make battery 12 volt, 150 AH with fitting clamps compatiable for existing Diesel Engine

-

-

-

... More
Renovation of Fire Detection system

-

-

-

... More
Checking, Cleaning, Servicing and repainting of Valves Including replacement of Gland Packing with repair of valve, if found necessary, complete in all respect

-

-

-

... More
Checking & Servicing of Fire Pumps including electrical motors and diesel engine inside Fire Water Pump House and recommisioning of the same as per system requirement complete in all respect

-

-

-

... More
Supply, instalaltion & commisioning of new electronic battery charger with auto / maual boost / trickle charging facility for new battery for Diesel Engine to be installed in existing MCC cubicle

-

-

-

... More
Refilling of Stored Pressure ABC type Dry Chemical Powder of 5 kg capacity as per IS: 15683

21

-

-

... More
100NB CI Non-Return Valve, IS: 5312,

1

-

-

... More
Motor Driven Jockey Pump

1

-

-

... More
Yard Hydrant Valves, IS: 5290, Type-A,

4

-

-

... More
"Fire Exit →"

5

-

-

... More
Supply and Laying of 2c x 1.5 sq.mm FRLS shielded Cooper cable (For Loop) through with 20 mm PVC FR type Rigid conduit pipe with necessary arrangements as per G.S. (Make: Finolex/ Polycab/RR)

300

-

-

... More
Internal Hose Reel 20 mm dia x 30 m long with Shut Off Nozzle conforming IS: 884,

6

-

-

... More
Refilling of 9L capacity Water CO2 Extinguishers as per IS: 15683

10

-

-

... More
Supply & installtion of the following

-

-

-

... More
CI Non-Return Valve

-

-

-

... More
Checking & cleaning with Leakage repair (if any) and repainting of eitire fire water header, Pipe Line and wet riser for Fire Control System

1

-

-

... More
200NB CI Foot Valve, IS: 4048,

2

-

-

... More
80NB CI Foot Valve, IS: 4048,

1

-

-

... More
Electrical Motor Driven Horizontal centrifugal type Main Fire Pump with 60 H P Compton Greaves make Induction motor with all accessories / fittings

1

-

-

... More
Checking of All Electrical Wiring including Earth Pits and necessary Rectification,if any

1

-

-

... More
80NB CI Sluice Valve, NRS, IS: 14846, PN: 1.6

1

-

-

... More
100NB CI Sluice Valve, NRS, IS: 14846, PN: 1.6

2

-

-

... More
50NB( one nos valve may be replace for priming line)

4

-

-

... More
Kirlosker 85 H P. Diesel Engine Driven Stand-By Pump with Engine with all accessories / fittings with supply of lubricant, coolant, oil & disel filter and diesel in the fuel tank

1

-

-

... More
150NB CI Non-Return Valve, IS: 5312,

2

-

-

... More
150NB CI Sluice Valve, NRS, IS: 14846, PN: 1.6

4

-

-

... More
Refilling ABC type Dry Chemical Powder of 4 kg capacity as per IS: 15683

8

-

-

... More
"Don't use Lift during Fire"

6

-

-

... More
Supply, Installation,Testing & Commisioning of Addressable Manual Call Point ( VDS / UL /ERTL/ LPCB / FM approved ) with in built short circuit fault isolator as per NFPA style 7 wiring complete as required. (Approved Make: Honeywell- Esser)

3

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.