The PWD has issued a formal invitation for competitive bids for the Public Works Department project, for Construction Of G Plus 3 Storied Building For 50 Beded Critical Care Block At Malda Medical in Malda, West Bengal. The bid opening date for this tender is 23-05-2025 and the last date for bid submission is 13-06-2025. Interested bidders for Public Works Department tender can download the important documents here to check the tender amount, scope of work, eligibility criteria and technical requirements.

Public Works Department - PWD Tender

Works
Building Construction
Eprocure
Opening Date23 May 2025
Closing Date13 Jun 2025
Tender AmountRefer Documents 
Notes
Download

Costs

Summary

Construction Of G Plus 3 Storied Building For 50 Beded Critical Care Block At Malda Medical

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Make : CUMMINS /Caterpiller/Kirloskar/Ashok leyland/Mahindra/Perkins/Koel/Greaves

-

-

-

... More
Engine Type : 4 Stroke Diesel Engine

-

-

-

... More
RPM : 1500

-

-

-

... More
Duty : PRIME

-

-

-

... More
Cooling : Coolant with radiator

-

-

-

... More
Cylinder : 6 or Higher

-

-

-

... More
Aspiration : Turbo Charged

-

-

-

... More
Type of Governor : Electronic

-

-

-

... More
Fuel Tank Capacity : Minimum capacity 750 Ltrs or Higher

-

-

-

... More
Fuel Consumption as per OEM standard

-

-

-

... More
Overload Capacity : 10% overload for one hour for every 12 hours continuous running at full load or better

-

-

-

... More
Engine instrument Panel : Consisting of starting switch with Key, Lube Oil Indicator, water temperature Indicator, RPM indicator and hour meter.

-

-

-

... More
Safety Controls : Emergency Stop, Low Lube Oil Pressure warning/ Shutdown, High Engine Coolant Temp. warning/ Shutdown, Sensor failure Indicator, Engine over speed indicator, Battery charging and low battery indicator

-

-

-

... More
Exhaust Silencer : Residential Type/ Hospital Grade

-

-

-

... More
Starting system : 12V/ 24 V. starting system complete with starter motor, charging alternator with rectifier and Cutout as per manufacturer standard.

-

-

-

... More
Battery : Lead Acid, Low Maintenance or SMF and conforming to relevant IS Specification with Low/High Battery Voltage and Weak Battery warning

-

-

-

... More
ALTERNATOR

-

-

-

... More
Make : Stamford/ Leroy Somer/kirloskar/ABB/Crompton/Mahindra

-

-

-

... More
Rating : 415 V, 3Ph. 50 Hz., 625/650 KVA, 1500 rpm

-

-

-

... More
Type : Brushless, self excited and self regulated

-

-

-

... More
Insulation : Class H

-

-

-

... More
Protection : screen-protected drip proof with Min.IP-23 degree of protection

-

-

-

... More
RPM : 1500

-

-

-

... More
Voltage Regulation (max) : ±1%

-

-

-

... More
Winding connection : Star with Neutral

-

-

-

... More
Total Distortion factor : Less than 5%

-

-

-

... More
AMF PANEL (CPRI Approved)

-

-

-

... More
Cubical type floor mounted AMF panel made from 14 SWG Sheet Steel, duly pretreated, powder coated painted and aesthetically finished, suitable for controlling of 625/650 KVA DG set having following specification/features. Manufactured by the OEM / CPRI approved panel builder.

-

-

-

... More
i) 415V, 1000 A or higher, 50KA, EDO type ACB with O/L, S/C, E/F protection and microprocessor based LSING protection release, U/V release etc. [make : Legrand / Siemens/ Schneider Electric/ LK /ABB] - 2 Sets.

-

-

-

... More
ii) Supply & Fixing of 1100A, capacity 99.9% - 99.5% electrolytic tinned copper (Certificate should be produced by tmanufacturer) with multicolor heat shrinkable PVC sleeve on 4 Bus Bar (Size of flat 4 nos. x (60 mm x10 mm) or higher) of required length mounted on non-hygroscopic porcelain insulator having sufficient di-electric strength duly insulated by multicolor (Red, Yellow, Blue & Black) heat shrinkable PVC sleeve for phases & neutral identification. All interconnection/branches should be made with required size of cu bars (Cu-bar extensions of required shape and current carrying capacity may have to be provided at terminals of ACB as per direction of EIC) & remote monitoring of internal temparature of every bus section & cable alley should be provided -1 set

-

-

-

... More
iii) 415V, 630A, 4 pole 50 kA (Uimp=8KV), Ics= 100% Icu MCCB microprocessor based release having adjustable O/L (0.4 to 1x In or better), Adjustable S/C (1/1.5 - 8/10 Ir), as outgoing to Chiller Panel & CCB building Panel, [make : Legrand / Siemens/ Schneider Electric/ LK /ABB] - 2 Set

-

-

-

... More
iv) In Built By-Pass switch for rated capacity

-

-

-

... More
v) On -delay timer for load change over

-

-

-

... More
vi) On-delay timer for engine shut off

-

-

-

... More
vii) Engine On-Off switch (Push button type)

-

-

-

... More
viii) Battery charger complete with voltage regulator, booster selector switch, on-off switch, voltmeter and ammeter for charging the battery from mains. This will be in addition to the battery charging alternator fitted on the engine.

-

-

-

... More
ix) Minimum five number indicating lamps to indicate 'mains ON', 'load on mains', Set running', 'load on set' and 'battery charger on'.

-

-

-

... More
x) Audio visual alarm for 'Low lubricating oil pressure', 'High coolant temperature, Start failure', and DG over load'.

-

-

-

... More
xi) Mode selector for setting the panel on Auto/ Main/ Test Mode.

-

-

-

... More
xii) Microprocessor based relay with composite meter for digital display of following.

-

-

-

... More
a) Generator voltage/AC Mains voltage.

-

-

-

... More
b) Generator Current in all phases

-

-

-

... More
c) Frequency

-

-

-

... More
d) Power Factor

-

-

-

... More
e) Indication for alternator supply

-

-

-

... More
f) Running time indications number of hours of operation and service intervals, service due indications

-

-

-

... More
The AMF panel must be designed to ensure trouble free performance and ensure switching over Electrical Load to DG within 15 (fifteen) second from the instant of mains failure.

-

-

-

... More
ACOUSTIC ENCLOSURE

-

-

-

... More
The DG set should have integrated acoustic enclosure at the manufacturing state itself. High quality acoustic enclosure must be certified as per CPCB-IV+ norms.

-

-

-

... More
BASE FRAME

-

-

-

... More
Common iron channel fabricated base frame containing the engine and alternator, mounted on AVM pads and having provision for lifting Hook.

1

10

-

... More
TERMS & CONDITIONS

-

-

-

... More
(i) Necessary manufacturer's test certificate for Diesel Engine, Alternator etc. Will have to submit in triplicate copy during delivery of the equipment.

-

-

-

... More
(ii) Copy of "Type Approval Certificate" and Certificate of "COP" must be produced at the time of delivery issued from competent Authority (As per CPCB-IV+).

-

-

-

... More
(iii) Circuit Diagram for AMF Panel must be submitted from the Manufacturer/OEM and should be approved by EIC.

-

-

-

... More
(iv) The entire set must be warranted at least 15 months from the date of Delivery/12 months/ 5000 Hrs from the date of Commissioning whichever is earlier. However Engine & Alternator should be warranted of 2 years/5000 Hrs, whichever is earlier.

-

-

-

... More
SUPPLY & INSTALLATION EXHAUST STACK

-

-

-

... More
Supply & fixing of exhaust gas piping of suitable dia welded black 250mm dia MS class B pipe incl all necessary bend supports and clamps anti vibration mounting insilation of exhaust system with 50mm thick mineral wool covered with mesh and aluminium cladding ( from DG sets to top of the building plus 3mtr or as per CPCB IV+) for 625/650KVA DG set as per direction of EIC

20

10

-

... More
S&F special type lattice (box) MS structure by MS angle of size 65 x 65 x 8 mm thick for 2 (four) nos main structure with 50 x 50 x 6 mm thick MS bracing incline nature properly welded and proper foundation 1 ft x 1 ft x 2 ft height for holding the MS structure in straight position during running of DG Exhaust pipe incl painting as per direction of EIC.

20

10

-

... More
S&F rain protection canopy for 20 mtr. long 200mm Exhaust pipe.

1

10

-

... More
Hire charges for scaffolding by bamboo required rope of square type arrangement for smooth working & carriage of MS black pipe by vertical run & dismantling at the end of work.

1

10

-

... More
SUPPLY & LAYING CONTROL CABLES

-

-

-

... More
Supply & drawing 1.1KV grade 7 core 2.5 sqnn stranded unarmoured PVC insulated copper control cable from DG to AMF Panel.(Make- Polycab/Finolex/Gloster/R R Kabel).

50

10

-

... More
EARTHING

-

-

-

... More
Earthing with 65 mm dia GI pipe (TATA-Medium)x 3.0 Mts. long and 1 No. 50 mm x 6 mm galvanized (Hot Dip) steel strip (4 Mts. long), 20 mm dia x 125 mm long galvanized bolt, double nuts, double washers including finishing both ends by making holes etc. and S & F 65 mm dia GI pipe (ISI-Medium) protection (3 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level to an average depth of 3.65 Mts. [Ref.- G-1/D] Body, AMF & Neutral earthing for 625 kVA DG Set

6

10

-

... More
Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe.

6

10

-

... More
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 50 mm x6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required.

20

10

-

... More
S& laying 2 x 120 sq. mm. single core multistrand PVC insulated flexible Al. wire in suitable size of PVC flexible pipe (reinforced) from nutral earth busbar to DG neutral point as required (for DG neutral earthing)

15

10

-

... More
MISCELLANEOUS

-

-

-

... More
Supply & delivery of best quality oil hand pump with 1" dia PVC flexible pipe (12' ft. approx.) (Brand approved by EIC)

1

10

-

... More
Supply & Delivery of 500 Ltrs Capacity heavy gauge MS Sheet barrel with MS angle made support stand.

1

10

-

... More
Supply & Making of fuel pipe line complete with 40mm MS pipe, ball valve, elbow, matching flanges , gaskets, nut bolts etc.

10

10

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.