Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.

Public Works Department - PWD Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date24 May 2025
Closing Date18 Jun 2025
Tender Amount₹ 2,71,37,200 
Notes
Download

Costs

Summary

Construction Of G Plus 2 Storied Linac Building And Proposed Horizontal And Vertical Extension Up To (g Plus 9) With Provision Of 10 Storied Of Linac Building (g Plus 2) At 1 Harish Mukherjee Road At Ipgmer - Sskm Hospital, Kolkata - Sitc Of Lift

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Load : 20 Passenger / 1360 Kg

-

-

-

... More
Control: Microprocessor based with AC variable voltage & variable frequency ( VVVF)

-

-

-

... More
Machine:- Energy efficient machine, Gearless, With Machine Room

-

-

-

... More
Position of Machine Room: Directly above the lift

-

-

-

... More
Speed:1.0 Mtrs./ Sec

-

-

-

... More
Floor served: G+9, 10-stop & 10-opening

-

-

-

... More
Landing: 10 (Ten), all on same (front) side

-

-

-

... More
Total Rise : 35.1 Mtr (Approx) (Bidder should visit the site)

-

-

-

... More
Operation: Microprocessor based implex full collective with or without attendant.

-

-

-

... More
Signals: Digital car position indicator,car travels direction indicator in car & at all landing with call registration indicator.

-

-

-

... More
Leveling accuracy:±5 mm(Micro levelling arrangement)

-

-

-

-

-

-

... More
Car inside :1300 mm ( W ) x 2400 mm ( D ) x 2200 mm (H) or As per manufacturer's standard conforming to IS

-

-

-

... More
Car Entrance : Clear Opening 1100 mm (W) x 2000 mm (H ) protected with car door

-

-

-

... More
Car Enclosure: Stainless Steel sheet (20 SWG) with Hairline finish with hand rail.

-

-

-

... More
Car Ceiling & Lighting: Stainless Steel with hairline finish with LED lighting and Fan

-

-

-

... More
Car Ventilation: Minimum 2 nos Radial/Pressure Blower fan with anodised aluminium grill.

-

-

-

... More
Car Flooring : Decorative 25mm granite flooring (As per direcion of EIC and according to this Department's Order).

-

-

-

... More
Car Door: Stainless Steel centre opening automatic door provided with V3F controlled door drive system

-

-

-

... More
Landing Door: Stainless steel centre opening automatic door provided with V3F controlled door drive system

-

-

-

... More
Door Opening: Automatic power oprated door with full length Photocell assembly light curtain sensor

-

-

-

... More
Car operating panel : A best quality Screen touch car operating panel with floor indication and digital hall position & direction indicatiors.

-

-

-

... More
Landing operating panel : A best quality Screen touch car operating panel with floor indication and digital hall position & direction indicatiors.

-

-

-

... More
Fire Rated Door : 2 Hours

-

-

-

... More
PROTECTIVE DEVICES & OTHER ACESSORIES

-

-

-

... More
ARD: Automatic rescue device complete with dry maintenance free batteries as required for automatic evacuation to the nearest floor in case of power failure / single phasing/others.

-

-

-

... More
Overload Protection:Fully loaded with overload protection.On overloading the lift car will not start with door remaining open and give audio display indication

-

-

-

... More
Emergency lighting in car: Battery operated emergency lighting in the lift car.

-

-

-

... More
Intercom system: Battery operated intercom system in Lift Car, Machine Room & Control Room

-

-

-

... More
Emergency Alarm: Battery operated alarm bell system in lift car and control room

-

-

-

... More
Fireman switch: Fireman switch at main landing terminal.

-

-

-

... More
Voice Synthesizer: Voice announcement system (Voice Synthesizer) in the car to announce the position of the elevator in the hoist way as the car passes or stops at a floor served by the elevator.

-

-

-

... More
Main rope - Belt Type (Flat Coated steel belt with V groove / Sreel rope)

-

-

-

... More
Communication & Monitoring the Lift : Lift controller/ Panel shall be Ethernet/Modbus ready with necessary converter, DC Power supply module etc. if required, and there shuld be single Ethernet/Modbus output from the Controller/panel and the same should be connected to BMS (Building Management System) and the controller/ panel should have also required for monitoring of real time data with date & time, maintenance-call back record, Mantrap notice, call records, location of car, Lift room temperature etc. should be noticed & display to in any desktop & mobile though wireless system.

-

-

-

... More
Other works: Necessary cutting of wall/floor for fixing the Fire Alarm switch, all Button switch and also making provision to entry of rope, electric wire etc. as required to complete the job.

-

-

-

... More
DIMENSION OF SHAFT & POWER SUPPLY

-

-

-

... More
Available Shaft Dimension: 2350(W) mm X 3000(D)mm (Bidder should visit the site)

-

-

-

... More
Pit Depth : 1750 mm (Bidder should visit the site)

-

-

-

... More
Overhead : 5000 mm (Bidder should visit the site)

-

-

-

... More
Electric power supply: AC 415 Volt 3phase, 50 Hz, including suitable Earthing continuity from dedicated Earth Electrodes terminated in machine room as per IS standard requirement.

-

-

-

... More
CCTV & COMMUNICATION:

-

-

-

... More
Provision for CCTV interface in CAR & Lift room.

-

-

-

... More
External monitoring system through MOD BUS RS485/ TCP IP Ethernet and IOT based communication system from control panel of the lift upto plug & play device installed at lift machine room or designated location for remote monitoring of the lift operation including display of instantaneous parameters such as voltage, currents, power, Energy, power factor etc and recorded parameters such as nature of fault, breakdown history, maximum load with date & time stamp, maintenance (PM) dates etc and generating reports from remote PC based server system.

-

-

-

... More
SITC of Automatic Lift ( as per manufacturer design & as per detailed specification below conforming to IS ) and putting into operation after final testing in the existing lift shaft complete with all accessories and repairing the damage wall / floor if any etc to complete as reqd. (Simplex System operation)

1

-

-

... More
Make : OTIS / KONE/SCHINDLER

-

-

-

... More
Type: Bed cum passenger Lift .

-

-

-

... More
Load : 20 Passenger / 1360 Kg

-

-

-

... More
Control: Microprocessor based with AC variable voltage & variable frequency ( VVVF)

-

-

-

... More
Machine:- Energy efficient machine, Gearless, With Machine Room

-

-

-

... More
Position of Machine Room: Directly above the lift

-

-

-

... More
Speed:1.0 Mtrs./ Sec

-

-

-

... More
Floor served: G+9, 10-stop & 11-opening (Both side opening at ground floor only)

-

-

-

... More
Landing: 10 (Ten), ground floor on both (front & rear) sides, 1st floor to 9th floor all are on same (front) side.

-

-

-

... More
Total Rise : 35.1 Mtr (Approx) (Bidder should visit the site)

-

-

-

... More
Operation: Microprocessor based implex full collective with or without attendant.

-

-

-

... More
Signals: Digital car position indicator,car travels direction indicator in car & at all landing with call registration indicator.

-

-

-

... More
Leveling accuracy:±5 mm(Micro levelling arrangement)

-

-

-

-

-

-

... More
Car inside :1300 mm ( W ) x 2400 mm ( D ) x 2200 mm (H) or As per manufacturer's standard conforming to IS.

-

-

-

... More
Car Entrance : Clear Opening 1100 mm (W) x 2000 mm (H ) protected with car door

-

-

-

... More
Car Enclosure: Stainless Steel sheet (20 SWG) with Hairline finish with hand rail.

-

-

-

... More
Car Ceiling & Lighting: Stainless Steel with hairline finish with LED lighting and Fan

-

-

-

... More
Car Ventilation: Minimum 2 nos Radial/Pressure Blower fan with anodised aluminium grill.

-

-

-

... More
Car Flooring : Decorative 25mm granite flooring (As per direcion of EIC and according to this Department's Order).

-

-

-

... More
Car Door: Stainless Steel centre opening automatic door provided with V3F controlled door drive system

-

-

-

... More
Landing Door: Stainless steel centre opening automatic door provided with V3F controlled door drive system

-

-

-

... More
Door Opening: Automatic power oprated door with full length Photocell assembly light curtain sensor

-

-

-

... More
Car operating panel : A best quality Screen touch car operating panel with floor indication and digital hall position & direction indicatiors.

-

-

-

... More
Landing operating panel : A best quality Screen touch car operating panel with floor indication and digital hall position & direction indicatiors.

-

-

-

... More
Fire Rated Door : 2 Hours

-

-

-

... More
PROTECTIVE DEVICES & OTHER ACESSORIES

-

-

-

... More
ARD: Automatic rescue device complete with dry maintenance free batteries as required.for automatic evacuation to the nearest floor in case of power failure / single phasing/others.

-

-

-

... More
Overload Protection:Fully loaded with overload protection.On overloading the lift car will not start with door remaining open and give audio display indication

-

-

-

... More
Emergency lighting in car: Battery operated emergency lighting in the lift car.

-

-

-

... More
Intercom system: Battery operated intercom system in Lift Car, Machine Room & Control Room

-

-

-

... More
Emergency Alarm: Battery operated alarm bell system in lift car and control room

-

-

-

... More
Fireman switch: Fireman switch at main landing terminal.

-

-

-

... More
Voice Synthesizer: Voice announcement system (Voice Synthesizer) in the car to announce the position of the elevator in the hoist way as the car passes or stops at a floor served by the elevator.

-

-

-

... More
Main rope - Belt Type (Flat Coated steel belt with V groove / Sreel rope)

-

-

-

... More
Communication & Monitoring the Lift : Lift controller/ Panel shall be Ethernet/Modbus ready with necessary converter, DC Power supply module etc. if required, and there shuld be single Ethernet/Modbus output from the Controller/panel and the same should be connected to BMS (Building Management System) and the controller/ panel should have also required for monitoring of real time data with date & time, maintenance-call back record, Mantrap notice, call records, location of car, Lift room temperature etc. should be noticed & display to in any desktop & mobile though wireless system.

-

-

-

... More
Other works: Necessary cutting of wall/floor for fixing the Fire Alarm switch, all Button switch and also making provision to entry of rope, electric wire etc. as required to complete the job.

-

-

-

... More
DIMENSION OF SHAFT & POWER SUPPLY

-

-

-

... More
Available Shaft Dimension: 2350(W) mm X 3000(D) mm (Bidder should visit the site)

-

-

-

... More
Pit Depth : 1750 mm (Bidder should visit the site)

-

-

-

... More
Overhead : 3900 mm (Bidder should visit the site)

-

-

-

... More
Electric power supply: AC 415 Volt 3phase, 50 Hz, including suitable Earthing continuity from dedicated Earth Electrodes terminated in machine room as per IS standard requirement.

-

-

-

... More
CCTV & COMMUNICATION:

-

-

-

... More
Provision for CCTV interface in CAR & Lift machine room/ Control Panel area.

-

-

-

... More
External monitoring system through MOD BUS RS485/ TCP IP Ethernet and IOT based communication system from control panel of the lift upto plug & play device installed at lift machine room or designated location for remote monitoring of the lift operation including display of instantaneous parameters such as voltage, currents, power, Energy, power factor etc and recorded parameters such as nature of fault, breakdown history, maximum load with date & time stamp, maintenance (PM) dates etc and generating reports from remote PC based server system.

-

-

-

... More
SITC of Automatic Lift ( as per manufacturer design & as per detailed specification below conforming to IS ) and putting into operation after final testing in the existing lift shaft complete with all accessories and repairing the damage wall / floor if any etc to complete as reqd. (Simplex System operation)

2

-

-

... More
Make : OTIS / KONE/SCHINDLER

-

-

-

... More
Type: Bed cum passenger Lift .

-

-

-

... More
Load : 20 Passenger / 1360 Kg

-

-

-

... More
Control: Microprocessor based with AC variable voltage & variable frequency ( VVVF)

-

-

-

... More
Machine:- Energy efficient machine, Gearless, With Machine Room

-

-

-

... More
Position of Machine Room: Directly above the lift

-

-

-

... More
Speed:1.0 Mtrs./ Sec

-

-

-

... More
Floor served: G+9, 9-stop & 9-opening (as 4th floor is void).

-

-

-

... More
Landing: 09 (Nine), all are on same (front) side.

-

-

-

... More
Total Rise : 35.1 Mtr (Approx) (Bidder should visit the site)

-

-

-

... More
Operation: Microprocessor based implex full collective with or without attendant.

-

-

-

... More
Signals: Digital car position indicator,car travels direction indicator in car & at all landing with call registration indicator.

-

-

-

... More
Leveling accuracy:±5 mm(Micro levelling arrangement)

-

-

-

-

-

-

... More
Car inside :1300 mm ( W ) x 2400 mm ( D ) x 2200 mm (H) or As per manufacturer's standard conforming to IS.

-

-

-

... More
Car Entrance : Clear Opening 1100 mm (W) x 2000 mm (H ) protected with car door

-

-

-

... More
Car Enclosure: Stainless Steel sheet (20 SWG) with Hairline finish with hand rail.

-

-

-

... More
Car Ceiling & Lighting: Stainless Steel with hairline finish with LED lighting and Fan

-

-

-

... More
Car Ventilation: Minimum 2 nos Radial/Pressure Blower fan with anodised aluminium grill.

-

-

-

... More
Car Flooring : Decorative 25mm granite flooring (As per direcion of EIC and according to this Department's Order).

-

-

-

... More
Car Door: Stainless Steel centre opening automatic door provided with V3F controlled door drive system

-

-

-

... More
Landing Door: Stainless steel centre opening automatic door provided with V3F controlled door drive system

-

-

-

... More
Door Opening: Automatic power oprated door with full length Photocell assembly light curtain sensor

-

-

-

... More
Car operating panel : A best quality Screen touch car operating panel with floor indication and digital hall position & direction indicatiors.

-

-

-

... More
Landing operating panel : A best quality Screen touch car operating panel with floor indication and digital hall position & direction indicatiors.

-

-

-

... More
Fire Rated Door : 2 Hours

-

-

-

... More
PROTECTIVE DEVICES & OTHER ACESSORIES

-

-

-

... More
ARD: Automatic rescue device complete with dry maintenance free batteries as required.for automatic evacuation to the nearest floor in case of power failure / single phasing/others.

-

-

-

... More
Overload Protection:Fully loaded with overload protection.On overloading the lift car will not start with door remaining open and give audio display indication

-

-

-

... More
Emergency lighting in car: Battery operated emergency lighting in the lift car.

-

-

-

... More
Intercom system: Battery operated intercom system in Lift Car, Machine Room & Control Room

-

-

-

... More
Emergency Alarm: Battery operated alarm bell system in lift car and control room

-

-

-

... More
Fireman switch: Fireman switch at main landing terminal.

-

-

-

... More
Voice Synthesizer: Voice announcement system (Voice Synthesizer) in the car to announce the position of the elevator in the hoist way as the car passes or stops at a floor served by the elevator.

-

-

-

... More
Main rope - Belt Type (Flat Coated steel belt with V groove / Sreel rope)

-

-

-

... More
Communication & Monitoring the Lift : Lift controller/ Panel shall be Ethernet/Modbus ready with necessary converter, DC Power supply module etc. if required, and there shuld be single Ethernet/Modbus output from the Controller/panel and the same should be connected to BMS (Building Management System) and the controller/ panel should have also required for monitoring of real time data with date & time, maintenance-call back record, Mantrap notice, call records, location of car, Lift room temperature etc. should be noticed & display to in any desktop & mobile though wireless system.

-

-

-

... More
Other works: Necessary cutting of wall/floor for fixing the Fire Alarm switch, all Button switch and also making provision to entry of rope, electric wire etc. as required to complete the job.

-

-

-

... More
DIMENSION OF SHAFT & POWER SUPPLY

-

-

-

... More
Available Shaft Dimension: 2350(W) mm X 3000(D) mm (Bidder should visit the site)

-

-

-

... More
Pit Depth : 1750 mm (Bidder should visit the site)

-

-

-

... More
Overhead : 5000 mm (Bidder should visit the site)

-

-

-

... More
Electric power supply: AC 415 Volt 3phase, 50 Hz, including suitable Earthing continuity from dedicated Earth Electrodes terminated in machine room as per IS standard requirement.

-

-

-

... More
CCTV & COMMUNICATION:

-

-

-

... More
Provision for CCTV interface in CAR & Lift machine room/ Control Panel area.

-

-

-

... More
External monitoring system through MOD BUS RS485/ TCP IP Ethernet and IOT based communication system from control panel of the lift upto plug & play device installed at lift machine room or designated location for remote monitoring of the lift operation including display of instantaneous parameters such as voltage, currents, power, Energy, power factor etc and recorded parameters such as nature of fault, breakdown history, maximum load with date & time stamp, maintenance (PM) dates etc and generating reports from remote PC based server system.

-

-

-

... More
SITC of Automatic Lift ( as per manufacturer design & as per detailed specification below conforming to IS ) and putting into operation after final testing in the existing lift shaft complete with all accessories and repairing the damage wall / floor if any etc to complete as reqd. (Simplex System operation)

2

-

-

... More
Make : OTIS / KONE/SCHINDLER

-

-

-

... More
Type: Automobile Elevator (Car Lift)

-

-

-

... More
Load : 3000 Kg

-

-

-

... More
Control: Microprocessor based with AC variable voltage & variable frequency ( VVVF)

-

-

-

... More
Machine:- Energy efficient machine, Gearless, With Machine Room

-

-

-

... More
Position of Machine Room: Directly above the lift

-

-

-

... More
Speed:0.5 Mtrs./ Sec

-

-

-

... More
Floor served: G+3, [3-stop (at Ground, 2nd & 3rd Floors) & 3-opening (at front side at ground floor and at rear side at 2nd & 3rd Floors)].

-

-

-

... More
Landing: 3 (Three) [at Ground, 2nd & 3rd Floors) (at front side at ground floor and at rear side at 2nd & 3rd Floors].

-

-

-

... More
Total Rise : 12.3 Mtr (Approx) (Bidder should visit the site)

-

-

-

... More
Operation: Microprocessor based implex full collective with or without attendant.

-

-

-

... More
Signals: Digital car position indicator,car travels direction indicator in car & at all landing with call registration indicator.

-

-

-

... More
Leveling accuracy:±5 mm(Micro levelling arrangement)

-

-

-

-

-

-

... More
Car inside :2600 mm ( W ) x 5600 mm ( D ) x 2700 mm (H) or As per manufacturer's standard conforming to IS.

-

-

-

... More
Car Entrance : Clear Opening 2400 mm (W) x 2400 mm (H ) protected with car door

-

-

-

... More
Car Enclosure: Stainless Steel sheet (20 SWG) with Hairline finish with hand rail.

-

-

-

... More
Car Ceiling & Lighting: Stainless Steel with hairline finish with LED lighting and Fan

-

-

-

... More
Car Ventilation: 4 nos cross-flow fan with anodized aluminium grill.

-

-

-

... More
Car Flooring : Skid-proof steel flooring.

-

-

-

... More
Car Door: Stainless Steel centre opening automatic door provided with V3F controlled door drive system

-

-

-

... More
Landing Door: Stainless steel centre opening automatic door provided with V3F controlled door drive system

-

-

-

... More
Door Opening: Automatic power oprated door with full length Photocell assembly light curtain sensor

-

-

-

... More
Car operating panel : A best quality Screen touch car operating panel with floor indication and digital hall position & direction indicatiors.

-

-

-

... More
Landing operating panel : A best quality Screen touch car operating panel with floor indication and digital hall position & direction indicatiors.

-

-

-

... More
Fire Rated Door : 2 Hours

-

-

-

... More
PROTECTIVE DEVICES & OTHER ACESSORIES

-

-

-

... More
ARD: Automatic rescue device complete with dry maintenance free batteries as required.for automatic evacuation to the nearest floor in case of power failure / single phasing/others.

-

-

-

... More
Overload Protection:Fully loaded with overload protection.On overloading the lift car will not start with door remaining open and give audio display indication

-

-

-

... More
Emergency lighting in car: Battery operated emergency lighting in the lift car.

-

-

-

... More
Intercom system: Battery operated intercom system in Lift Car, Machine Room & Control Room

-

-

-

... More
Emergency Alarm: Battery operated alarm bell system in lift car and control room

-

-

-

... More
Fireman switch: Fireman switch at main landing terminal.

-

-

-

... More
Voice Synthesizer: Voice announcement system (Voice Synthesizer) in the car to announce the position of the elevator in the hoist way as the car passes or stops at a floor served by the elevator.

-

-

-

... More
Main rope - Belt Type (Flat Coated steel belt with V groove / Sreel rope)

-

-

-

... More
Communication & Monitoring the Lift : Lift controller/ Panel shall be Ethernet/Modbus ready with necessary converter, DC Power supply module etc. if required, and there shuld be single Ethernet/Modbus output from the Controller/panel and the same should be connected to BMS (Building Management System) and the controller/ panel should have also required for monitoring of real time data with date & time, maintenance-call back record, Mantrap notice, call records, location of car, Lift room temperature etc. should be noticed & display to in any desktop & mobile though wireless system.

-

-

-

... More
Other works: Necessary cutting of wall/floor for fixing the Fire Alarm switch, all Button switch and also making provision to entry of rope, electric wire etc. as required to complete the job.

-

-

-

... More
DIMENSION OF SHAFT & POWER SUPPLY

-

-

-

... More
Available Shaft Dimension: 4000(W) mm X 6300(D) mm (Bidder should visit the site)

-

-

-

... More
Pit Depth : 1800 mm (Bidder should visit the site)

-

-

-

... More
Overhead : 6900 mm (Bidder should visit the site)

-

-

-

... More
Electric power supply: AC 415 Volt 3phase, 50 Hz, including suitable Earthing continuity from dedicated Earth Electrodes terminated in machine room as per IS standard requirement.

-

-

-

... More
CCTV & COMMUNICATION:

-

-

-

... More
Provision for CCTV interface in CAR & Lift machine room/ Control Panel area.

-

-

-

... More
External monitoring system through MOD BUS RS485/ TCP IP Ethernet and IOT based communication system from control panel of the lift upto plug & play device installed at lift machine room or designated location for remote monitoring of the lift operation including display of instantaneous parameters such as voltage, currents, power, Energy, power factor etc and recorded parameters such as nature of fault, breakdown history, maximum load with date & time stamp, maintenance (PM) dates etc and generating reports from remote PC based server system.

-

-

-

... More
Charges for minor civil works such as cutting hole in wall/floor/slab as required for smooth & safe erection/installation of seven nos. Lift (as per manufacturer design & as per detailed specification below conforming to IS) other than major civil works executed by PWD Civil wing and putting into operation after necessary testing in the existing lift shaft complete with all accessories and repairing the damaged wall / floor if any etc to complete & handover the SITC work of Lifts in all respect in the important Hospital building as per direction of the E.I.C.

120

-

-

... More
Terms and Condition:

-

-

-

... More
i) The Agency must procure the materials from the Manufacturer / OEM or from their authorised sales channel so that the standard warranty / support of the Manufacturer / OEM becomes applicable to the products to be delivered and installed by them.

-

-

-

... More
ii) Documents that authenticates such procurement from the Manufacturer / OEM or from their authorized sales channel and standard warranty / support should be sent from the e-mail of the Manufacturer / OEM / authorized sales channel to the e-mail of Engineer-in-Charge and hard copy of it to be submitted during execution, of work/submission of bill.

-

-

-

... More
iii) The rate quoted by the manufacturer should be inclusive of cost for providing 2 years DLP after completion of 1 year of initial commisioning.

-

-

-

... More
iv) Rates should be quoted with minor civil works, wall cutting and mending good the damages to the original finish.

-

-

-

... More
v) If any refurbished material is supplied and installed, penal action will be taken as per existing rules

-

-

-

... More
(Rates should be Quoted inclusive of all taxes & duities and L.W.C. @ 1% as applicable)

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.