The PWD has issued a formal invitation for competitive bids for the Public Works Department project, for Proposed Three Storied P.K. Mukherjee Mahavidyalaya In the District of Alipurduar---External Electrical Installation Work in Cooch Behar, West Bengal. The bid opening date for this tender is 13-05-2025 and the last date for bid submission is 02-06-2025. Interested bidders for Public Works Department tender can download the important documents here to check the tender amount, scope of work, eligibility criteria and technical requirements.

Public Works Department - PWD Tender

Works
Eprocure
Opening Date13 May 2025
Closing DateCancelled
Tender AmountRefer Documents 
Notes
Download

Costs

Summary

Proposed Three Storied P.K. Mukherjee Mahavidyalaya In the District of Alipurduar---External Electrical Installation Work

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Bus bar section : 415 V, 315 Amp capacity 99.9% – 99.5% electrolytic tinned 4 bar copper bus bar mounted on non-hygroscopic porcelain insulator / hylam sheet having sufficient di-electric strength duly wrapped with colour PVC tapes (Red, yellow, blue & black) for phases & neutral identification- 1 set.

-

-

-

... More
The busbar is to be rigidly supported on suitable non-hygroscopic insulating materials of robust ration to with stand electromechanical stress in the event of earth fault. All connection to bus to made by suitable nuts & bolts. The busbar is too wrapped with coloured PVC (Red. Yellow, Blue & Black) for colour identifications.

-

-

-

... More
Outgoing Arrangement : a) 415V 200 Amps TPN SFU units with HRC fuses (Make:- L&T/SIEMENS/ABB/ SCHNEIDER) in open execution.---- 2 No.

-

-

-

... More
b) 415V 160 Amps TPN SFU units with HRC fuses (Make:- L&T/SIEMENS/ABB/ SCHNEIDER) in open execution.---- 3 No.

-

-

-

... More
c) 415V 63 Amps TPN SFU units with HRC fuses (Make:- L&T/SIEMENS/ABB/ SCHNEIDER) in open execution.---- 2 No.

-

-

-

... More
(d) E.I. Danger Board of suitable size ------- 1 no.

-

-

-

... More
Metering Panel:- a)Digital multifunction meter with selector push button switch (up/down) with Voltage, Current, Frequency, Total Harmonic Distortion, PF, KW, KVA, Kwh, KVAh and Preloaded Max & Min Demand with Date & Time Stamping display (Make-Schneider Electric/ Class accuracy CIo.5S, POP of Accuracy Class 0.5S or equivalent model of Legrand/ Siemens/ L&T) - 1 No.

-

-

-

... More
b) Indicating LED Lamp with colour glasses showing (Red/Yellow/Blue/Amber) (Siemens cat.no 3SB5285-6HC03, 3SB5285-6HD03, 3SB5285-6HF03 or equivalent cat of L&T/ABB/ SCHNEIDER) - 1 No.

-

-

-

... More
c) 500/5 Amp ratio C.T (Kappa or equivalent) --- 3 nos.

-

-

-

... More
d)S & F 2 Amp SPMCB for auxiliary supply to meters (Make- SIEMENS/L&T/Legrand) - 1 no.

-

-

-

... More
Interconnection :- All interconnection between incoming main to Busbar are to be made with suitable size electrolytic tinned copper bars or equivalent flexible pvc insulated multistranded single core Cu cable and the same between busbar to each outgoing mains and & for metering arrangements are to be made by suitable size of Copper with proper socketing of the end of each wire leads.

-

-

-

... More
Earthing Arrangement :- A separate continuous aluminum earth busbar of appropriate size is to be painted at the inside bottom of the panel and run across the full load of the panel board. All electrical equipment are to be properly earthed with suitable size G.I. strip.

-

-

-

... More
The complete panel board is to be spray painted after required surface treatment by 7 tanks process / sand blasting with 2 coat of red oxide primer & 2 coat of finished paint over dried or powder coating.

-

-

-

... More
Installation :- The complete panel board is to be installed on suitable brick padestal as directed by the E.I.C.

-

-

-

... More
Supply and installation of Emergrncy L.T. cubical type fully compartmentalized distribution panel board, having rigid and self supporting structure fabricated with 14 SWG CRCA sheet with M.S. angle iron frame (main frame with 50 x 50 x 6 mm angle and each vertical compartment with 40 x 40x6 mm MS angle iron). The base of panel should be made with 75mm x 40mm x 4.4 mm M.S. channel. [Manufacturer/Fabricator having Test Certificates from CPRI]. An Auto Cad Drawing of the panel has to approved by EIC before making of panel.

1

-

-

... More
Construction Details : All incoming & outgoing switches are to be housed in respective compartments hinged and gasket doors at the front. All doors should have panel locking arrangement in such a fashion that it can not be on unless the feeder remains in off position. The rear panel should gasketed wire net guard for ventilation arrangement will be made of easy accessibility to each compartment by providing rear panel doors with locking system . The panel is to be properly gasketed to prevent the dust & vermin. All vertical bus bar chambers is to properly arrange and all electrical equipments are to be fixed by nuts and bolts on suitable Hylam board / porcelain insulators of adequate size and dimension. The outgoing feeder connection from respective switches are to be made at rear side of panel by means of busbar, copper multi core cables, to be terminated on bolted type terminals for cable connection or on bush insulators for bus bar connection. Each compartment will be providing with DMC/FRP board at back side.

-

-

-

... More
Incoming Arrangement : a) 415 Volts, 200 A, TPN SFU with proper HRC fuse (open execution type) (Make: L&T/Legrand/Schenider/ABB/Siemens)- 2 No.

-

-

-

... More
b) 415 Volts, 200A, on load front operated TPN changeover switch (open execution type) (Make: L&T /Legrand/ Schenider /ABB /Siemens)- 1No.

-

-

-

... More
Bus bar section : 415 V, 315 Amp capacity 99.9% – 99.5% electrolytic tinned 4 bar copper bus bar mounted on non-hygroscopic porcelain insulator / hylam sheet having sufficient di-electric strength duly wrapped with colour PVC tapes (Red, yellow, blue & black) for phases & neutral identification- 1 set.

-

-

-

... More
The busbar is to be rigidly supported on suitable non-hygroscopic insulating materials of robust ration to with stand electromechanical stress in the event of earth fault. All connection to bus to made by suitable nuts & bolts. The busbar is too wrapped with coloured PVC (Red. Yellow, Blue & Black) for colour identifications.

-

-

-

... More
Outgoing Arrangement : a) 415V 160 Amps TPN SFU units with HRC fuses (Make:- L&T/SIEMENS/ABB/ SCHNEIDER) in open execution.---- 6 Nos.

-

-

-

... More
b) 415V 32 Amps TPN SFU units with HRC fuses (Make:- L&T/SIEMENS/ABB/ SCHNEIDER) in open execution.---- 4 Nos.

-

-

-

... More
c) 415V 63 Amps TPN SFU units with HRC fuses (Make:- L&T/SIEMENS/ABB/ SCHNEIDER) in open execution.---- 2 Nos.

-

-

-

... More
(d) E.I. Danger Board of suitable size ------- 1 no.

-

-

-

... More
Metering Panel:- a) Digital multifunction meter with selector push button switch (up/down) with Voltage, Current, Frequency, Total Harmonic Distortion, PF, KW, KVA, Kwh, KVAh and Preloaded Max & Min Demand with Date & Time Stamping display (Make-Schneider Electric/ Cat No- EM6400NG Class accuracy CIo.5S, POP of Accuracy Class 0.5S or equivalent model of Legrand/ Siemens/ L&T) - 1 No.

-

-

-

... More
b) Indicating LED Lamp with colour glasses showing (Red/Yellow/Blue/Amber) (Siemens cat.no 3SB5285-6HC03, 3SB5285-6HD03, 3SB5285-6HF03 or equivalent cat of L&T/ABB/ SCHNEIDER) - 1 No.

-

-

-

... More
c) 500/5 Amp ratio C.T (Kappa or equivalent) --- 3 nos.

-

-

-

... More
d)S & F 2 Amp SPMCB for auxiliary supply to meters (Make- SIEMENS/L&T/Legrand) - 1 no.

-

-

-

... More
Interconnection :- All interconnection between incoming main to Busbar are to be made with suitable size electrolytic tinned copper bars or equivalent flexible pvc insulated multistranded single core Cu cable and the same between busbar to each outgoing mains and & for metering arrangements are to be made by suitable size of Copper with proper socketing of the end of each wire leads.

-

-

-

... More
Earthing Arrangement :- A separate continuous aluminum earth busbar of appropriate size is to be painted at the inside bottom of the panel and run across the full load of the panel board. All electrical equipment are to be properly earthed with suitable size G.I. strip.

-

-

-

... More
The complete panel board is to be spray painted after required surface treatment by 7 tanks process / sand blasting with 2 coat of red oxide primer & 2 coat of finished paint over dried or powder coating.

-

-

-

... More
Installation :- The complete panel board is to be installed on suitable brick padestal as directed by the E.I.C.

-

-

-

... More
Sub Head 2 : S & F TPN SFU Supplying and fixing 415V, TPN SFU with sheet steel enclosure on angle iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating. (Make:- L&T/SIEMENS/ABB/ SCHNEIDER) 32 A

2

-

-

... More
SUB-HEAD 3 --Supply & Laying of Cable Supply of 2/4 Core XLPE Insulated & Sheathed Armoured stranded Aluminium Conductor cables for Working Voltage up to 1100 Volts of following sizes [Make- Polycab / RR /KEI/ Havells as approved by E.I.C]

-

-

-

... More
4 core 120 Sq. mm (From WBSEDCL meter to Building Main panel & Main Switch to AMF Panel & DG to Building Panel via AMF)

220

-

-

... More
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below :

-

-

-

... More
4 core 120 Sq. mm

12

-

-

... More
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials :

-

-

-

... More
4 core 120 Sq. mm

12

-

-

... More
Laying of one No. cable above 35 sqmm and upto 185 sqmm in underground trench 460mm wide x 760mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per Mtr. including filling the space between the bricks and cable and also the trenchwith shifted soil, leveling up and restoring surface duly rammed

220

-

-

... More
SUB-HEAD 4 --EARTHING INSTALLATION Excavation of soil for installation of Earth Electrode and filling & ramming. (For Soft Soil)

30

-

-

... More
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below:

-

-

-

... More
By TATA-Medium GI pipe

16

-

-

... More
Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe.

8

-

-

... More
Extra treatment of soil by using salt & charcoal for pipe electrode as to G.S.

8

-

-

... More
Supply & fixing earth busbar of galvanized (Hot dip) MS flat 25 mm x 6 mm on wall having clearence of 6 mm from wall incl. providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required.

20

-

-

... More
Connecting the equipments body to earth busbar including S&F 20 mm x 3 mm galvanised (Hot Dip) MS flat on wall/floor with GI saddles as required and connection to equipments incl. drilling holes, with bolts, nuts, washers etc.

180

-

-

... More
SUB-HEAD 5 --Compound Lights Fixing only Floodlight fittings on top of masonary structure by 3 Nos. 10 mm dia x 87 mm long rag bolts, nuts & double washers complete either 37 mm x 10 mm MS flat support/or by other means as required.

24

-

-

... More
Supply & Drawing 1.1 KV grade 3Core 22/0.3 (1.5 sqmm) XLPE insulated Un-armoured Cu Cable (Brand approved by EIC) for connection from loop box to fittings through 20 mm size PVC Rigid Conduit 'FR' [PrecisionMake] including making connections as necessary.

80

-

-

... More
Supply & Delivery of 240V, LED street lights with optic lens and polycarbonate diffuser having following wattage, in white powder coated pressure die cast aluminium housing with IP 66 protection & incl. 10 kV SPD, with glare free uniform illumination with CCT (5700K-6500K) having minimum luminous efficiency of 110 Lm/ Watt or better & 50,000 LED burning hours or more. [Make- Philips/ Crompton/ Wipro or manufacturer with own NABL accredited lab with valid test certificate] [LED lamps & accessories shall have BEE certification] 120 W

10

-

-

... More
Supply & Delivery of 240V, LED flood lights with optic lens and polycarbonate diffuser having following wattage, in white powder coated pressure die cast aluminium housing with IP 66 protection & incl. 10 kV SPD, with glare free uniform illumination with CCT (5700K-6500K) having minimum luminous efficiency of 110 Lm/ Watt or better & 50,000 LED burning hours or more. [Make- Philips/ Crompton/ Wipro or manufacturer with own NABL accredited lab with valid test certificate] [LED lamps & accessories shall have BEE certification] 120 Watt

14

-

-

... More
Supplying & Fixing GI waterproof type looping cable box size 200x150x100 mm deep having 4 mm thick comprising of one 250 V 15 A kit-kat fuse unit, one NL on porcelain insulator, one compression type brass cable gland for upto 2- core 16 sqmm PVC/A cable and having lined with rubber gasketted GI top cover with brass machine screws etc., earthing terminal with lug, on steel tubular pole near base, including S&F 40x6 mm thick, MS clamps with bolts, nuts etc. including painting with anticorrosive paint.

25

-

-

... More
Supply & fixing of SS enclosure (2+10) with IP 43 protection, powder coated, provision for housing DP Contactor, concealed in wall after cutting the wall & mending good the damages to original finish/ on flat iron frame incl painting, connection & provision for earthing attachment incl. foloowing accessories. [Make:Legrand /Schneider /Siemens /Crabtree/ L&T] [NS] .

2

-

-

... More
i)40 A DP MCB Isolator -1no

-

-

-

... More
ii) 25 A double pole Contractor -1no.

-

-

-

... More
iii) Programmable Digital time switch -1no.

-

-

-

... More
iv) Toggle Switch-1No

-

-

-

... More
v) LED indication lamp- 1 set (1 Red & 1 Green)

-

-

-

... More
with complete interconnection and locking arrangement as per direction of E.I.C.

-

-

-

... More
Supply of 2/4 Core XLPE Insulated & Sheathed Armoured stranded Aluminium Conductor cables for Working Voltage up to 1100 Volts of following sizes [Make Polycab / RR /KEI/ Havells/ Gloster as approved by E.I.C] 2 core 10 Sq. mm

762

-

-

... More
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below : 2 core 10 Sq. mm

28

-

-

... More
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials : 2 core 10 Sq. mm

28

-

-

... More
Laying of cable as below, after cutting floor /pavement / wall/ and making holes incl., embedding the cable at an average depth as below and mending good the damages to original finish incl. removing the rubbish. From 2.5 sqmm to 35 sqmm at an average depth of 75 mm in floor/pavement/wall etc.

762

-

-

... More
Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required 32 mm Dia

40

-

-

... More
SUB-HEAD 6 -- SITC of DG & allied works Supply , delivery at site on foundation , commissioning of 82.5 KVA, 415V, 50Hz, 3Ø silent new DG Set, comprising of Engine, alternator, Base frame, Fuel tank, Battery, CPCB-IV+ approved Engin & Acoustic Enclosure including transportation, loading and unloading of the DG set, having following specifications [ Make: JAKSON / KOEL GREEN / GREAVES POWER ]

1

-

-

... More
ENGINE Make : CUMMINS / KIRLOSKAR / GREAVES POWER Engine Type : 4 or 6 Stroke Diesel Engine RPM : 1500 Rated Output : 102 BHP or Higher Duty : PRIME Cooling : Water cooled with radiator Cylinder : 4 Aspiration : Turbo Charged Type of Governer : Electronic Fuel Tank Capacity : Minimum capacity 150 Ltrs. Fuel Consumption at 75% rated Load with Radiator or Fan : 13.8 Ltr./ Hr. or Less Fuel Consumption at 100% rated Load with Radiator or Fan : 18.8 Ltr./ Hr. or Less Overload Capacity : 10% overload for one hour for every 12 hours continious running at full load or better Engine instrument Panel : Consisting of starting switch with Key, Lube Oil Indicator, water temperature Indicator, RPM indicator and hour meter. Safety Controls : Emergency Stop, Low Lube Oil Pressure warning/ Shutdown, High Engine Water Temp. warning/ Shutdown, Sensor failure Indicator, Engine overspeed indicator, Battery charging and low battery indicator Exhaust Silencer : Residential Type Starting system : 12V./ 24 V. starting system complete with starter motor, charging alternator with rectifier and Cutout as per manufacturer standard.

-

-

-

... More
Battery : Lead Acid, Low Maintenance or SMF and conforming to relevant IS Specification with Low/High Battery Voltage and Weak Battery warning ALTERNATOR Make : STAMFORD / KIRLOSKAR GREEN / GREAVES POWER / LEROY SOMER Rating : 415 V., 3Ph. 50 Hz., 82.5 KVA, 1500 rpm Type : Brushless, self excited and self regulated Insulation : Class H Protection : Screen-protected drip proof with Min.IP-23 degree of protection RPM : 1500 Voltage Regulation (max) : ±1% Winding connection : Star with Neutral Total Distortion factor : Less than 3% Total Harmonic distortion in output waveform : < 5% ACOUSTIC ENCLOSURE The DG set should have integrated acoustic enclosure at the manufacturing state itself. High quality acoustict enclosure must be certified as per CPCB-II norms. BASE FRAME Common iron channel fabricated base frame containing the engine and alternator, mounted on AVM pads and having provision for lifting Hook.

-

-

-

... More
TERMS & CONDITIONS (i) Rate should be quoted inclusive of all applicable taxes and Duty etc. (ii) All materials, equipments & accessories must conform to relavent IS /IEC specifications. The DG Set to be supplied must be from the authorized OEM of the respective Engine Manufacturer. (iii) Nacessary manufacturer's test certificate for Desiel Engin, Alternator etc. Will have to submit in triplicate copy during delivery of the equipment. (iv) Copy of "Type Approval Certificate" and Certificate of "COP" must be produced at the time of delivery issued from competant Authority (As per CPCB-IV+). (v) Circuit Diagram for AMF Panel must be submited from the Manufacturer/OEM. (vi) The entire set must be warranted atleast 15 months from the date of Delivery/12 months/ 5000 Hrs from the date of Commissioning whichever is earlier. However Engine & Alternator should be warranted of 2 years/5000 Hrs, whichever is earlier.

-

-

-

... More
Supplying and fixing exhaust gas piping (200 MM Diameter ). welded black MS, B class pipe conforming to IS: 3589 cut to required lengths and installed with necessary bends, supports and clamps, anti-vibration mountings, insulation of exhaust system with mineral wool / Rockwool, 100 mm thick wiremesh and aluminium cladding etc., as per requiremement of pollution control norms and required as per direction of Engineer-in-Charge and manufacturer recomendation.

15

-

-

... More
Earth work in excavation of foundation trenches or drains in all sorts of soil (including mixed soil but excluding laterite or sand stone) including removing, spreading or stacking the spoils within a lead of 75m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. (a) Depth of excavation not exceeding 1,500 mm.

1.7

-

-

... More
Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work) (a) With earth obtained from excavation of foundation

1.7

-

-

... More
Removal of rubbish,earth etc. from the working site and disposal of the same beyond the compound, in conformity with the Municipal / Corporation Rules for such disposal, loading into truck and cleaning the site in all respect as per direction of Engineer in charge

1.7

-

-

... More
Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand.(payment to be made on measurement of finished quantity

2.57

-

-

... More
Cement concrete with 30 mm down graded shingles excluding shuttering. N.B. Variety (a) 1:3:6 proportion.(i) Pakur Variety

0.6

-

-

... More
Brick work with 1st class bricks in cement mortar (1:6) in foundation and plinth

3

-

-

... More
Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works . 25 mm to 30 mm shuttering as per decision & direction of Engineer-In-Charge

1.4

-

-

... More
Steel shuttering or 9 to 12 mm thick approved quality ply board shuttering in any concrete work

12.5

-

-

... More
Holding down bolt with nut including 100 x 100 x 6 mm plate washer at bottom fitted complete and packing the hole with cement concrete or cement grout as directed 16 mm dia bolt - 450 mm long

16

-

-

... More
Ordinary Cement concrete (mix 1:1.5:3) with graded stonechips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes. (Pakur Variety.)

0.6

-

-

... More
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc. initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at inter-section, complete as per drawing and direction. (a) For works in foundation, basement and up to roof of ground floor/up to 4m. (SAIL/ TATA/RINL)

0.1

-

-

... More
Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand.

6.8

-

-

... More
Plaster ( to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering conrners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (ground floor). [Excluding cost of chipping over concrete surface]. (i) With 1:6 cement mortar, (b) 20 mm thick plaster

14.4

-

-

... More
Neat cement punning about 1.5mm thick in wall, dado, windowsill, floor etc. NOTE:Cement 0.152 cu.m per100 sq.m.

14.4

-

-

... More
M.S. structural works with hollow sections ( square or rectangular shape) conforming to IS: 806-1957 & IS:1161-1958) connected to one another with bracket, gusset, cleat as per design, drawing & direction of Engineer-in-Charge complete including cutting to requisite shape & size, fabrication including metal arc welding conforming to IS: 816-1956 & IS: 9595 using electrodes of approved make and brand conforming to IS:814- 1957, haulage, hoisting and erection all complete. The rate includes the cost of all M.S. Hollow section, all consumables such as electrodes, gas and hire charges of all tools and plants and labour reqired for execution and all incidental chages (such as electricity, labour insurance) etc. complete. For roof truss works- Span up to 12 Mtr

0.5

-

-

... More
Suppling, fitting and fixing single skin color coated trapezoidal profile for wall cladding, Roof shall be made of 0.45mm BMT (Base Metal Thickness) (0.50mm TCT(Total coated thickness excluding paint), G550 (min 550 yield strength), of Zincalume metallic coating (IS15965) with high Solar Reflectance Index (SRI) value for better colling as per thermatech technology, 1000-1015mm effective cover width with five major corrugation, 28mm high rib spaced at 203mm c/c with subtle square fluting in the pan and the end rib shall have anti-capillary groove and return leg.The steel sheet shall be fastened with 40 micron cine coated or 25 micron zine-tin alloy coated, hex head, self-drilling screw as per IS 3566-2002 Class 3 fastener. The base steel shall be conted with inc-aluminium alloy Zincalume (AZ150 )(.e. 55% Al, 43.4% Zine, 1.6% Si) minimum of 150 g/m2 coating total on both sides, pre-painted. with colorbond XRW (xterior roofing, walling paint system of 15 micron Super Durable Polyester paint (SDP) with stable inorganic pigment with no lead contents confirming IS15965. The sheet shall be free from defects and have brand marking of the manufacturer giving product details on the back of the sheet at regular interval confirming genuinits of the material. In Roof- With 0.5 mm thick sheet

9.5

-

-

... More
Galvanised iron sheet ridging fitted with necessary bolts, screws, washers etc complete.(225mm end lapping) 450 mm lapping each way- With 0.63 mm sheet

4

-

-

... More
Priming one coat on timber or plastered surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc.

4.7

-

-

... More
Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc.

4.7

-

-

... More
Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand parpering etc. in cluding using of approved putty etc. on the surface , if necessary. On timber or plastered surface: With super gloss (hi-gloss) : Two coats (with any shade except white).

4.7

-

-

... More
Artificial stone in floor, dado, staircase etc with cement concrete (1:2:4) with stone chips, laid in panels as directed with topping made with ordinary or white cement (as necessary) and marble dust in proportion (1:2) including smooth finishing and rounding off corners including raking out joints or roughening of concrete surface and application of cement slurry before flooring works using cement @ 1.75 kg/sq.m all complete including all materials and labour. In ground floor Using grey cement (ii) 25 mm. thick

6

-

-

... More
Supplying fitting and fixing door made with IRC fabric mesh of 75mm x 50mmx4.5mmx2.7mm on 50mm x 50mm x 6mm angle iron frames all round and one 37.5mm x 6mm M.S. flat bar over the netting all round welded to angle iron frame and providing locking arrangements if necessary and with two coats of synthetic enamel paint(Other than Hi-gloss) fitted and fixed with clamps or haskal doomney etc. complete including flat stiffeners on every 1.0 m apart both ways. ( Cost of Concrete for fixing will be paid separately)

25

-

-

... More
SUB-HEAD 7 --LED SIGN BOARD SITC of Glowsign Board ( Router cutting) with liquid Acrlyic letters with adhesive on ACP Board of 3 mm Thick (Make – Aludecor / Alstone) of suitable size to accommodate all the matters / contains as approved by the authority to be made with 25 x 25 x 4 mm M.S angle Iron, 18 S.W. G square /Round Hollow bar, Base plate (10 mm Thickness) requires for fixing the necessary Nuts, Bolts, Washers, supporting angle Iron, Clamp etc. and ACP Sheet on Front sides & edges only & back side to be covered by GI Sheet (with proper ventilation arrangement), All side to be moulded uniformly, Side fabricated by Aluminium ‘L’Channel, upon which elevated or box type letter made from imported liquid acrylic will be fixed. The Thickness of Acrylic will be 5 mm (for small letters), 8 mm (for Big letters) and 10 mm (for very big letters). The Back Side of the letters is covered by 3 mm thick ACP (Make – Aludecor / Alstone). The inside of the letter of the letter Supplying and Fixing of best Quality LED Lighting arrangement of fully water proof 10 nos. LED light fittings of 20 watt (100 lumen / watt). The letters are sealed by exterior grade Silicon. The back side of the Board Covered by 22 S.W.G G.I sheet with Nuts & Bolts. (Signage 40 Sq Ft/ 10 Ft x 4 Ft)

1500

-

-

... More
Intensity: Same & smooth uniform throughout without any dark patch.

-

-

-

... More
Visibility: Up to 250 meters for normal eyes.

-

-

-

... More
The complete sign board would be fixed on roof of the building with providing necessary CC muffing, 1 no CI water proof 200 x 150 x 100 mm loop Box, 50 x 50 x 6 mm MS angel for supporting the board of required length by nuts, bolts, washers etc. After drilling holes on the frame front facia. GSB would have 2 nos. hinge type doors in back side to have the inside access including mending goods the damages to original finish.

-

-

-

... More
Painting of any steel / iron surface of the above Glow sign board with no. of coats of paints as given below with ready mixed paint / primer of approved make and brand incl. preparation of surface by sand paper / emery paper, cleaning etc. for receiving fresh coat of paint.

-

-

-

... More
1st coat of aluminium paint over one coat of RO priming.

-

-

-

... More
2nd coat of aluminium paint over one coat of RO priming.

-

-

-

... More
SUB-HEAD 8 -- Lightning Conductor S & F Lightning conductor Air-terminals made of 15 mm dia 1500 mm long GI pipe (ISI Medium) having five prongs of 4 SWG GI (Hot Dip) wire at top with 85 mm dia 6 mm thick GI base plate at bottom incl. necessary holes etc. duly grouted on the parapet etc. in CC mortar (4:2:1)

70

-

-

... More
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below:By ISI-Medium GI pipe

70

-

-

... More
Supply & fixing GI (Hot Dip) strips 20 mm x 3 mm thick for horizontal run on the Parapet/Roof/ Wall with GI Saddles 1100 mm apart incl. mending good the damages to building works

352

-

-

... More
Supply & fixing of GI (Hot Dip) strips 20 mm x 3 mm thick for vertical run on wall with GI saddles spaced not exceeding 1000 mm apart incl. mending good damages to building work

700

-

-

... More
Cutting cornices/ steps etc. including cutting recess in buildings etc. & supply & fixing 15 mm bore (ISI-Medium) GI pipe protection as below and mending good damages to the building works:

-

-

-

... More
Length upto 0.5 Mtr

40

-

-

... More
Length above 0.5 Mtr

40

-

-

... More
Hiring charges for scaffolding arrangement including dismantling at the end of work and carriage, for LC installation, per storey of building per vertical run

140

-

-

... More
Supply & Fixing of Testing Joints by 20 mm x 3 mm thick GI (Hot Dip) strip 125 mm long grouted on wall having clearance of 6 mm from wall for making connection with thimbles at the end of 7/10 SWG GI (Hot Dip) stranded Wire and 4 SWG GI (Hot Dip) wire of vertical conductor and conductor from earth electrode complete with S & F thimbles, GI bolts, nuts, check-nuts, spring washers etc. as required

70

-

-

... More
Making soldered joints between conductors and down pipes/ other metallic objects for 14 SWG GI (Hot Dip) wire including supply of necessary 4 SWG GI (Hot Dip) wire, jointing materials and painting with 2 (two) coats of bituminous paint

70

-

-

... More
Note1:Rate Should be Quoted with inclusive of all taxes, duties, cess as applicable.

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.