Public Works Department Tender
... More
The PWD has issued a formal invitation for competitive bids for the Public Works Department project, for Construction Of Proposed New G Plus 4 Storied Camposite Court Building On The Existing Vacant Land Under The Judgeship Of Cooch Behar Sadar Sitc Of Lift. in Cooch Behar, West Bengal, with an estimated contract value of Rs. 42,65,677. The bid opening date for this tender is 10-09-2026 and the last date for bid submission is 17-11-2026. Interested bidders for Public Works Department tender can download the important documents here to check the scope of work, eligibility criteria and technical requirements.
Public Works Department - PWD Tender - WB Tender
Opening Date10 Sep 2026
Closing Soon17 Nov 2026
Tender Amount₹ 42,65,677
Costs
EMD
₹ 85,314Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Construction Of Proposed New G Plus 4 Storied Camposite Court Building On The Existing Vacant Land Under The Judgeship Of Cooch Behar Sadar Sitc Of Lift.
Contact
Tender Id
2026_WBPWD_5023455_1Tender No
WBPWD/EE/CED/eNIT-49/2026-2027Tender Authority
Public Works Department ViewPurchaser Address
-Website
http://wbpwd.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
(ix) Car Enclosure: Stainless steel scratch proof (Moon Rock/Honeycomb/ Hairline Finish) on all sides and stainless steel decorative ceiling with fans (indirect throw) and LED fitting.
(x) The car flooring should be smooth and antiskid as approved by engineer-in-charge.
-
-
-
... More
(xi) Type of doors:-
(a) Car: Power operated, centre opening horizontal sliding stainless steel scratch proof (Moon Rock/Honeycomb/ Hairline Finish).
(b) Landing doors: stainless steel scratch proof .
(xii) A hand rail not less that 600mm long at 900mm above floor level to be fixed adjacent to control panel in the lift car.
(xiii) Voice announcement system in the car to announce the position of the elevator in the hoist way as the car passes or stops at floor served by the elevator.
(xiv) Closed loop Control System, protection
against power fluctuation, self diagnostic control,Landing doors 2 hours Fire rated,
-
-
-
... More
Overload detection and protection, Overspeed Governer, Dot Matrix LED D & P Indicators In Car &Landings, BMS Compatibility, tamper proof infrared curtain covering almost the
entire height of the lift car door, Alarm horn, Anti Nuisance Operation, CCTV camera system with 4 MP IP camera, suitable NVR and HDD for 30 days storage backup , Firemen switch, 2/3 way intercom, Emergency Stop Switch with battery backup for fan and light fitting for 1 hour, pit ladder.
-
-
-
... More
(xv) The lift doors shall have a vision panel to enable persons with hearing impairment to signal for help or assistance in the event of an emergency.
(xvi)An appropriate technological support be provided (Through emergency messaging |services or alarms etc.) to respond to the emergency requirements of person with hearing impairment or deafness.
(xvii) In case of failure of ARD or other electronic devices, a provision of manual rescue be provided.
(LIFT WELL DIMENTION= 2600X2500) BIDDER SHOULD VISIT THE SITE IN PRIOR
-
-
-
... More
20 passenger (1360kg)
1
1
-
... More
SUB HEAD LIFT-02 (13 PASSENGER)
-
-
-
... More
Supplying, Installation, Testing & Commissioning of following capacity passenger Machine room less (MRL) lift with regenerative drive as per CPWD General Specification for Electrical Works (Part-III Lift & Escalator) 2003, BIS Codes, NBC 2016 as amended upto date having provision for barrier free access as per Harmonised Guidelines & Standards for Universal Accessibility in India - 2021 of MoHUA, serving different floors in the lift shaft as per detailed specifications enclosed and as under including all other equipment and accessories complete as required:-
-
-
-
... More
(i) Speed-1 MPS
(ii) Floors-5 (G+4)
(iii) Travel -17 Meters (approx.) BIDDER SHOULD VISIT THE SITE IN PRIOR
(iv) Stops & opening- 5 stops and 5 openings
(v) Controller: A.C. variable voltage & variable
frequency
(vi) Automatic rescue device (ARD) complete with dry maintenance free batteries as required.
vii) Operation: Microprocessor based single automatic push button/simplex selective collective/duplex collective selective with/without attendant
(viii) Power-415 Volts+10%, 3 phase, 50 Hz, 4 wires system
(ix) Car Enclosure: Stainless steel scratch proof (Moon Rock/Honeycomb/ Hairline Finish) on all sides and stainless steel decorative ceiling with fans (indirect throw) and LED fitting.
-
-
-
... More
(x) The car flooring should be smooth and antiskid as approved by engineer-in-charge.
(xi) Type of doors (a) Car: Power operated, centre opening horizontal sliding stainless steel scratch proof (Moon Rock/Honeycomb/ Hairline Finish).
(b) Landing doors: stainless steel scratch proof .
(xii) A hand rail not less that 600mm long at 900mm above floor level to be fixed adjacent to control panel in the lift car.
(xiii) Voice announcement system in the car to announce the position of the elevator in the hoist way as the car passes or stops at floor served by the elevator.
-
-
-
... More
(xiv) Closed loop Control System, protection against power fluctuation, self diagnostic control, Landingdoors 2 hours Fire rated, Overload detection and
protection, Overspeed Governer, Dot Matrix LED D & P Indicators In Car & Landings, BMS Compatibility, tamper proof infrared curtain covering almost the entire height of the lift car door, Alarm horn, Anti Nuisance
Operation, CCTV camera system with 4 MP IP camera, suitable NVR and HDD for 30 days storage backup , Firemen switch, 2/3 way intercom, Emergency Stop Switch with battery backup for fan and light fitting for 1 hour, pit ladder.
(xv) The lift doors shall have a vision panel to enable persons with hearing impairment to
signal for help or assistance in the event of an emergency.
-
-
-
... More
(xvi) An appropriate technological support be provided (Through emergency messaging |services or alarms etc.) to respond to the emergency requirements of person with hearing impairment or deafness.
(xvii) In case of failure of ARD or other electronic devices, a provision of manual rescue be provided
(LIFT WELL DIMENTION= 1900X1900) BIDDER SHOULD VISIT THE SITE IN PRIOR
-
-
-
... More
13 passenger (884kg)
1
1
-
... More
Note: 1) All the above rates should be quoted inclusive of all taxes, duties and all ancilery charges with cost of maintenance, servicing, supply & replacement of spares for 1 (One) year from the date of commissioning. 2) Total is rounded off to the nearest rupees.
-
-
-