Public Works Department Tender

... More
The PWD has issued a formal invitation for competitive bids for the Public Works Department project, for Temporary Arrangement For Illumination, Pa System And Dg Set For Bus Buffer Zone At Century Ply Workshop , Pailan In Connection With Gangasagar Mela-2027 For 12 Days. in South 24 Parganas, West Bengal, with an estimated contract value of Rs. 7,00,380. The bid opening date for this tender is 03-11-2026 and the last date for bid submission is 19-11-2026. Interested bidders for Public Works Department tender can download the important documents here to check the scope of work, eligibility criteria and technical requirements.

Public Works Department - PWD Tender - WB Tender

Opening Date3 Nov 2026
Closing Soon19 Nov 2026
Tender Amount₹ 7,00,380 
This is an estimated amount, exact amount may vary.
Notes
Download

Costs

Description

Temporary Arrangement For Illumination, Pa System And Dg Set For Bus Buffer Zone At Century Ply Workshop , Pailan In Connection With Gangasagar Mela-2027 For 12 Days.

Contact

Unlock the Tender details

GEM & Bid Advisory Services

Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

Unlock the Tender details
... More
Providing on hire basis following switches etc. on wooden plank board or suitable iron frame incl. providing intercnnection wiring with socketing, earthing attachment etc. and dismentalling at the end function (with PWD/EIC approved materials). 415V, 100AMP, Offload Changeover switch

1

53

-

... More
Providing on hire main wiring with 1.1 KV grade Aluminium Conductor PVC / XLPE armoured cable of following sizes including laying in trench (at least 230 mm below ground) including dismantling the same and mending good the damages a) 4 Core 25 Sq. mm PVC / XLPE armorured cable per meter from meter to Panel

80

10

-

... More
Providing on hire main wiring with 1.1 KV grade Aluminium Conductor PVC / XLPE armoured cable of following sizes including laying in trench (at least 230 mm below ground) including dismantling the same and mending good the damages( Panel to TPNDB) a) 4 Core 16 Sq. mm PVC / XLPE armorured cable per meter

150

11

-

... More
Do-Do- Supplying & Drawing on Hire Basis Single Phase Dist Wiring With 2.5/ 4/6 Sqmm with Earth Wire (1x 2.5 / 1x4) Sqmm Or its equivalent PVC copper wiring in suitable alkhathene pipe on the hire basis incl. dismantling the same per meter (For TPNDB to SPNDB/Mobile Charger/Plug pt./LED Flood Light)

1820

12

-

... More
Distribution wiring in 2 or 3 x 1.5 Sqmm single core PVC copper wire to light/fan points incl. fixing holder, switch and double board etc. complete on hire basis and dismantling the same (Av. Run 8 mtr.)

155

13

-

... More
Supplying & providing on hire basis 250 watt LED Flood light complete with bracket and clamps on the pole including dismantling incl. replacement of fused lamp (As per approved by E.I.C.)

50

14

-

... More
Supplying & providing on hire basis 150 watt LED Flood light complete with bracket and clamps on the pole including dismantling incl. replacement of fused lamp (As per approved by E.I.C.)

30

15

-

... More
Supplying & providing single/twin LED fitting complete with tube, commercial type (4 ft) box type single/twin fitting on hire basis and dismantling the same (As per approved by E.I.C.)

110

16

-

... More
Supplying & providing on hire basis pendent light fittings with 18 watt LED lamp holder shade etc. complete including dismantling the same

45

17

-

... More
Supplying & providing 1 no Seperate 6 amp plug and Switch with 150X100X65mm MS/TW switch Board on Hire basis and dismantaling the same

60

18

-

... More
Providing & Earthing on hire basis with 50 mm dia GI Pipe 2.5 to 3 mtrs. Long and 6/8 SWG GI wire with galvanized nuts and bolts washer etc. below ground level on hire basis and dismantling the same

2

19

-

... More
LED STRUCTURE FOR GATE Hire and Labour charges for temporary Installation of of LED Board of Size 15’ x 8’ft capable to prevent wind pressure by attaching to M.S. structure(back side of board of suitable size MS angle/ MS hollow square/rectangle bar) by drilling hole incl. S&F special type steel nuts, bolts and washer . The matter of the LED sing board should be in English/Bengali/Hindi letters incl. all fixing facility, including jointing/setting the same part by part incl. S&F SMD module (Best Quality make) of required quantity for illumination and necessary interconnection with SMPS. The matter will be decided by the authority at later stage: (For 3 days)

1

20

-

... More
Making necessary arrangement for fixing the above LED board by making necy supporting structure made of wooden to resist heavy wind by S&F necy clamp, nuts-bolts etc and install the same at an height of 17 ft from road level .

1

21

-

... More
Supply & laying of 1.1kv grade 2x2.5sq mm +1x1.5 sq mm PVC insulated & unsheathed Cu wire drawn in 20mm dia PVC rigid hard pipe.

40

22

-

... More
Do-Do- 4way double door SP MCB DB with required nos of 6A/way MCB as out going & 1no 25A DP Isolator as incomer etc incl. earthing arrangement & dismantling after the function.

1

23

-

... More
Hire and Labour charges for construction of over head gate with wooden frame of dimension 30 ft x 10 ft ,16 ft hight from road level with strong bamboo /sulbullah post with required bacing & runner finished with decorative coloured cloth on wooden frame and facia as per direction of EIC. (For 3 days)

1

24

-

... More
Supply and laying 1.1 K.V. grade 2 core 4 sq mm PVC/Ar/ Al. Cable with 1x10 SWG GI wire.as per G.S.Through underground with 1.5 inch dia pvc hard pipe for necessary protection.

300

25

-

... More
Add. Extra charges beyond 3(three) days. @2% more of the basic rate per day for 9 days (on item no. 1 to 20 above). (Rate of this item will be governed by actual execution)

9

27

-

... More
S&F compression type gland, as per SOR and Finishing the end of following cable by crimping method incl.supplying fixing solderless socket (dowels Make) tape anticorrosive paste & jointing materials. 4x25 sq.mm PVC armoured Al. cable .

8

28

-

... More
4x16sq.mm PVC armoured Al. cable.

16

29

-

... More
2x4q.mm PVC armoured Al. cable.

6

30

-

... More
PA System Providing on hire basis Microphone with stand & necessary cable for connection & dismantling after the function. (2 set )

12

31

-

... More
Do-Do- 300W Amplifier set complete & dismantling after the function. (2 set)

12

32

-

... More
Do-Do-Horn & dismantling after the function. (6 set )

12

33

-

... More
Do-Do-Chordless Microphone & dismantling after the function & dismantling after the function. (2 set )

12

34

-

... More
Do-Do-drawing of twin core cable for Connection of speaker & dismantling after the function. (600 Mtr )

12

35

-

... More
DIESEL GENERATOR SET Supplying & providing & connecting with Existing electrical panel ( With appropriate cable supplied by Contractor )on hire basis different KVA Three phase DG set of Follwing Ratings and dismantling the same, excluding fuel charges i) 62.5 KVA Three phase for Each day ( 1 no DG Set/Location for 03 days )

3

36

-

... More
DIESEL GENERATOR SET Supplying & providing & connecting with Existing electrical panel ( With appropriate cable supplied by Contractor )on hire basis different KVA Three phase DG set of Follwing Ratings and dismantling the same, excluding fuel charges i) 62.5 KVA Three phase for each single day more than 3 days ( 1 no DG Set/Location for 1 location 09 days )

9

37

-

... More
DIESEL GENERATOR SET Supplying & providing & connecting with Existing electrical panel ( With appropriate cable supplied by Contractor )on hire basis different KVA Three phase DG set of Follwing Ratings and dismantling the same, excluding fuel charges i) 10 KVA Three phase for Each day ( 1 no DG Set/Location for 03 days )

3

38

-

... More
DIESEL GENERATOR SET Supplying & providing & connecting with Existing electrical panel ( With appropriate cable supplied by Contractor )on hire basis different KVA Three phase DG set of Follwing Ratings and dismantling the same, excluding fuel charges i) 10 KVA Three phase for each single day more than 3 days ( 1 no DG Set/Location for 01 location 09 days )

9

39

-

... More
Deployment of One no. Electrician & One no. Helper per shift per day (i.e. Total 3 nos Electrician & 3 nos Helper per day for 24 Hrs) for carring out all kind of EI maintenance & DG operations etc.

12

42

-

... More
18 % GST on the total amount from SL no 01 to 32

1

43

-

... More
Cost of supply and pouring Diesel Oil (For 62.5 KVA and 10 KVA DG Set) incl. fuel handling charge.

408

44

-

... More
1% LWC on the total amount from SL no 01 to 34

1

45

-

... More
Cost for temporary electrical Service Connection Charges to be paid to WBSEDCL/CESC authority.

1

46

100000

... More
Special Terms and conditions for Temporary E.I. Work - 1) Earthing should conform to IS specification. Earth Continuity wire should not be broken / Jointed. Single Earth continuity wire should be used from Earth Bus-Bar to the installation. 2) All 3ɸ Electrical Panel Should be earthed by two nos. of separate earthing and 1ɸ panel should be earthed by one no earthing. 3) MCB / Rewirable Fuse type Distrubution Board should be installed with proper Trip Current setting / fuse wires. However, MCB type DBs are preferable. 4) No Part of the Electrical Circuit in the pandal / Structure shall be within 12 inches of any decorative cloth / paper. 5) Ordinary Flexible wires should not be used. Only new PVC insulated & sheathed wires (Bearing ISI mark) or PVC insulated wires of FRLS (Fire Resistant Low Smoke) type (ISI Marked) are allowed. 6) All cable ends should be properly sockedted. 7) All joints shall be made with porceline insulated connectors. Twisted & lapped joints shall be avoided. But Joints are strictly not allowed in the dias. 8) Cables / Wires should run along outside the Dias. 9) Ceiling fan (s) / Electrical fittings must not be suspended from the ceiling of Dias. Pedestal fans are not allowed on the Dias. However, Pedestal fans may be installed outside dias, but the body of the fan must be properly earthed.

-

-

-

... More
10) T/L fittings shall be of box type (Indoor commercial type). Any kind of open type fittings must be avoided. 11) P.A. System and Microphone shoud be earthed. 12) Sufficient quantity of Fire Extinguishers and First Aid Box should be provided. 13) If the DGs are not placed at site on time pro rata rate will be reduced from bill. 14) The guarding /security arrangement of all the hired products /installation has to be made by the successful bidder at his/their own cost and responsibility. No additional charge will be paid for any unwanted incidents like theft, damage due to natural calamities or any other reasons whatsoever. 15) During entire hiring period any fault to the hired installation shall be rectified/faulty items replaced, at the cost of agency. Suitable man power for attending and rectification/replacement of damaged items has to be provided by the agency at their own cost. Rectification time is 1 hour for the event day and upto 2hrs for other days. 16) A test certificate cum safety certificate is to be provided by the agency, duly signed by the Supervisor of the agency after completion of installation. 17) A performance guarantee of hired DG sets has to be provided by the agency after completion. Note:- i) Item No. 34 is exepmted from GST, ii)Item No. 36 exempted from GST and LWC.

-

-

-



Evaluation Notes How It Works ?

Related Tenders

Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.