Public Works Department Tender
... More
The PWD has issued a formal invitation for competitive bids for the Public Works Department project, for Supply And Laying 50 Sqmm Lt Cable With Allied E.i Work At Ranaghat Fire Station, Ranaghat, Nadia in Nadia, West Bengal, with an estimated contract value of Rs. 3,38,554. The bid opening date for this tender is 30-10-2024 and the last date for bid submission is 12-11-2024. Interested bidders for Public Works Department tender can download the important documents here to check the scope of work, eligibility criteria and technical requirements.
Public Works Department - PWD Tender
Electrical Cables And Wires
Electrical and Electronics
Eprocure
Opening Date30 Oct 2024
Closing Date12 Nov 2024
Tender Amount₹ 3,38,554 This is an estimated amount, exact amount may vary.
Costs
EMD
₹ 6,583Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_WBPWD_766473_1Bid Award Id
ViewTender No
WBPWD/AE/e-NIT- 03/RH of 2024-25Tender Authority
Public Works Department ViewPurchaser Address
-Website
http://wbtenders.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Laying of following sizes 4 core Armoured/Aluminum conductor cable as below after cutting floor/pavement/wall and making holes incl. embedding the cables at an average depth as below and nending good the damages to original finish incl. removing the rubbish 50 sq. mm at an average depth of 75 mm in floor/pavement/wall etc. [ F 3 / 5 (i)]
20
-
-
... More
Sub Head 4 :SITC of AC Supply of 1.5 Tr. Split type Air - Conditioner Machine having following features - Cooling Capacity - 5300 Watts, Compressor - Rotary, EER -3.57 W/W, Star Rating - 3, Power Requirements 220/240 V 50 Hz, Remote Control - Yes, Main Unit Condenser Coil - Copper, Outdoor Unit Condenser Coil - Copper, Refrigerent - R410A / R32, Modes - Cool Mode - Yes, Sleep Mode - Yes, Timer - Yes, On-Timer: Yes, Off-Timer: Yes. (Make:Make: O-General, Model No. - ASGA18BMWA-B / Mistubishi Heavy Endustries / Mistubishi Electric
2
-
-
... More
Supply & laying 3/4" heavy type P.V.C. pipe for Water Drainage as per direction.(NS)
6
-
-
... More
240 V, 40 A DP
1
-
-
... More
Supply & drawing 3 core 2.5 sq. mm. P.V.C. insulated Copper wire for connecting the Power hub to ODU. (Make - Havells / Finolex / RR Kabel) (NS)
8
-
-
... More
Finishing of the XLPE / PVC insulated armoured cable ends by crimping method incl. supplying & fixing solder less socket ( DOWELS ) make , tapes , anticorrosive paste & jointing materials as per GS. 4 Core 50 sq. mm [ 7 C / F 4 ]
2
-
-
... More
Supplying and fixing 240 V, 6/10/16/20/25/32 A SP MCB of Breaking capacity 10 kA & C characteristics ( (Make - Siemens/ Legrand/Havells) on din rail of HTPN and SPN DBs and necessary connection. 7 / D-6.
22
-
-
... More
Supplying & fixing medium gauge GI pipe (ISI - Medium) protection with necessary fittings and jointing materials as required . 80 mm dia [F 6 / 11 (F) ]
24
-
-
... More
Installation, testing and commissioning of 1.5/1.8/2.0 Tr. split AC Machine with IDU & ODU including supply & fixing of 40 mm x 40 mm x 5 mm MS angle iron brackets (powder coated) with necessary nut- bolt etc. & mending good the damages.(NS)
2
-
-
... More
15.88 mm (5/8") dia
8
-
-
... More
Supplying and fixing 415 V, 32 A per way double door HTPN MCB DB (Make - Siemens/ Legrand/Havells) with IP-43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. inter connection with suitable size of copper wire and neutral link & provision for earthing attachment ---- [14 / D- 10 ] 4 Way
1
-
-
... More
Laying of one No. cable upto 35 sqmm in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed as per GS. [1(a)/F-2 ]
6
-
-
... More
Widrawing 3.5 /4 Core 16 Sq.mm LT cable from existing trench and laying the same in under ground trench 460mm wide x 760mm average depth with brick protection on the top of the cable with 8 (Eight) nos. bricks per Mtr. including filling the space between the bricks and cable and also the trench with shifted soil,leveling up and restoring surface duly rammed . asper GS . [NS] (For existing 3.5 /4 Core 50 Sq.mm LT cable sq.mm Lt Cable near Main Panel)
1
-
-
... More
SUB-HEAD 1-- SUPPLY & LAYING OF CABLES Supply of 1.1 kV Gr. 4 Core XLPE Insulated & Sheathed Armoured Aluminium Conductor cable [Make Gloster/Polycab/ Havells] of following sizes ---- 50 sq. mm [NS] [ From Proposed New Panel to New Barrack Building Panel ]
60
-
-
... More
Supplying and fixing compression type gland complete with brass gland , brass ring & rubber ring for dust & moisture proof entry of XLPE / PVC armoured cables as below Dowels make gland as per GS 4 Core 50 sq. mm [ 7 C / F 4 ]
2
-
-
... More
.Supply of 240V, 70 / 72 W LED Street light make Philips Cat no. BRP502 LED126 CW R3C PSU S1 / Wipro LR26-112-XXX-65-XX / Equivalent model of Havells ( For existig Steel Tubular Pole )
10
-
-
... More
Laying only Cable upto 50 sqmm through existing RCC/Hume/ GI Pipe/open masonary trench for single, 2, 3, 3½ & 4 core. [3 (b)/F-2 ]
24
-
-
... More
Sub Head 3 :-Earthing Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level by ISI Medium GI pipe as to GS (2 a / G1 ).
4
-
-
... More
Supplying and fixing of following rating 240/415 V 2/4 MCB type pole Isolator ( (Make - Siemens/ Legrand/Havells) on din rail of existing DBs and necessary connection. 6 / D-5. 415 V ,63 A FP
1
-
-
... More
S & F of 2 mm thick, stainless steel sheet fabricated, water proof type looping cable box (200 mm x 150 mm x 100 mm deep) comprising of one 240 V, 16 A kit-kat fuse unit, 4 nos. 16 A stud type connectors, lined with rubber gasketed hinged top cover with mechanical locking arrangement etc., earthing terminal with lug on pole above the muffing with S&F 2 nos. flat iron clamp set made with 30 mm x 4 mm thick flat iron bar with nut-bolt etc. suitable for fixing above mentioned loop box on the pole including painting with anticorrosive paint. NS
15
-
-
... More
Supply & drawing 4 core 1.5 sq. mm. P.V.C. insulated Copper wire for connecting the ODU TO IDU. (Make - Havells / Finolex / RR Kabel) (NS)
8
-
-
... More
Cutting Channel of 40 mm x 40 mm size on masonry wall by Electric operated cutting machine incl. supplying & fixing 19 mm dia 3 mm thick heavy gauge polythene pipe by means of anchoring chemical (Hilti/Sika), GI 'U' hooks of 8 SWG, 18 SWG GI wire as fish wire and mending good damages to original finish by using own tools and tackles. [6(b)/ E-3]
100
-
-
... More
Supplying & drawing of 1.1 KV. Gr. 3 core 1.5 sq. mm PVC insulated Cu. wire (Make - Finolex/Havells/Polycab) through 20 mm dia 3mm thick(uniformly) soft drawn polythene pipe from Pole Loop Box to LED fittings (NS)
200
-
-
... More
Fixing only outdoor / Street Light type fluorescent light fittings or LED light fittings complete with all other accessories to be fixed / projected from the wall of the building incl. making holes / providing 2 nos. MS clamping arrangement made with 40 mm x 6 mm MS flat & fixing 9 mm x 10 -150 mm nut bolts in wall after making hole in wall and mending good damages to finish also S & F 40 mm dia GI Pipe ISI make medium / required size dia GI pipe 1.50 mtr. average length having suitable bend / as per instruction of EIC incl. S & F necessary length of 3 x 1.5 sq.mm copper wire and making necessary connections as required and shoul;d be earthed properly and painting . (19 /C 3)
10
-
-
... More
Supply & laying of following sizes Refrigerant Copper Pipe (Minimum thickness 0.9 mm and Make - Royku / Totaline / Mandeep) with insulation by nitril rubber of minimum thickness 9 mm [Make Aroflex / Acoflex] also raping the insulation & Copper wire with GKB Gold non adhesive tape. (NS) 6.35 mm (1/4") dia
8
-
-
... More
Finishing of the following PVC insulated wire ends by socketting with pin/ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. [9/F-5] 3 x 22 / 0.3 (1.5 sq. mm) /2.5 Sq.mm
30
-
-
... More
S&F earth bus bar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall incl. providing drilled holes on the bus bar complete with GI bolts, nuts, washers, spacing insulators etc. as reqd. as to GS ( 4 a / G - 2)
1
-
-