Northeast Frontier Railway Tender

... More
The NFR has issued a formal invitation for competitive bids for the Northeast Frontier Railway project, for Rebuilding Of Br. No. 58 With 1 X 12.2 M Psc Slab On Pile Foundation On Permanent Diversion In Between Km. 50/9-51/6 In Between Byxa-atm Under Sr.aden/i/ncb. (s N T Associated Work). in Jalpaiguri, West Bengal, with an estimated contract value of Rs. 35,85,672. The bid opening date for this tender is 03-11-2026 and the last date for bid submission is 27-11-2026. Interested bidders for Northeast Frontier Railway tender can download the important documents here to check the scope of work, eligibility criteria and technical requirements.

Northeast Frontier Railway - NFR Tender - WB Tender

Opening Date3 Nov 2026
Closing Date27 Nov 2026
Tender Amount₹ 35,85,672.5 
Notes
Download

Costs

Description

Rebuilding Of Br. No. 58 With 1 X 12.2 M Psc Slab On Pile Foundation On Permanent Diversion In Between Km. 50/9-51/6 In Between Byxa-atm Under Sr.aden/i/ncb. (s N T Associated Work).

Contact

Unlock the Tender details

GEM & Bid Advisory Services

Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

Unlock the Tender details
... More
Excavation & Refilling of cable trench, 1.20 Meter deep and 0.3 Meter wide including clearing of roots of trees and bushes and temporary obstruction on the selected route, as per technical specifications and cable route plan.

900

90

81810

... More
Relay, AC immune, plug-in type, style QNA1, DC neutral line, 24V DC, 8F/8B contacts. 05 Front & back contacts metal to carbon, complete with plug board, retaining clip & connectors, confirming to BRS 931A, IRS:S-34 , IRS:S - 23 & IRS : S - 60. (as applicable) or latest. (Inspection Authority :RDSO)

30

5141

154239.9

... More
Supply of cable jointing tools as pre TS. (Inspection Authority: Consignee)

-

-

6

... More
Supply and fixing of GI pipe medium grade as per specification IS:1239 to carry all the cables with fixing materials and making necessary entry arrangement, at LC gates, cable huts, 02 ASM Room, At Bridges end, D class station and other building, as per requirement as per direction of site supervisor, using 50 mm dia G.I. Pipe. Note: All the materials e.g. G.I. Pipes (medium grade as per specification IS:1239), Clamps, PVC pipe, flexible PVC pipes, masonary materials, nuts & bolts are to be supplied by the contractor. (Inspection Authority: Consignee)

18

677

12188.34

... More
Supply , transportation and laying of PLB (HDPE) pipe of size 40/33 mm (nominal) along with all accessories required for fixing,clamping, cutting. (Inspection Authority: Consignee)

1000

67

67820

... More
Supply of Thermoshrink cable Jointing Kit for 6 QUAD Jelly filled cable as per spec. No. IRS:TC77/200, Rev.1,Amdt.-1 for Derivation 2T & straight through Joints. The Jointing kits are to be supplied from manufactures approved by RDSO. (Inspection Authority: RDSO)

10

3763

37631.5

... More
Provision of derivation/straight joints at approx. every Kilometer for Emergency 07 Sockets and L-C Gates from 6 QUAD cable, using PIJF/ 6 QUAD cable with the help of Thermo shrink Jointing kits and V.F. Transformers at locations decided by site Engineer. Jointing kit will be supplied against Sch A.

4

1856

7425.64

... More
Relay, AC immune, plug-in type, style QNA1, DC neutral line, 24V DC, 12F/4B contacts. Front & back contacts metal to carbon, complete with plug board, retaining clip & connectors, confirming to BRS 931A, IRS:S-34 , IRS : S - 23 & IRS : S - 60. (as applicable) or latest. (Inspection Authority :RDSO)

-

-

6

... More
Micro boring by HDT Machine including Pulling/drawing of cables as per site requirement including supply of PLB HDPE Ducts (63/57 mm) and its accessories and as per technical specifications.

1000

794

794670

... More
Transportation & Laying of underground signalling/ power/ telecom cables in trench, at bridges in pipes, in road crossing, platforms & across the track through GI/DWC/HDPE pipe as per technical specifications.

7500

6

46200

... More
Excavation, ramming, Casting Cement Concrete foundation and installation for 11 Apparatus cases/Location boxes in the ratio of 1:3:6 Aggregate not exceeding 3 : 8 cm, and technical specifications using standard size galvanized Anchor bolts & nuts (also referred to as foundation bolts) conforming to IRS Drg. No. SA-116A/M, for erection of Apparatus cases/Location boxes, plastering with 1 : 4 cement - sand mixture all the surfaces up to 75 mm below ground level, complete with contractor's material including cement, sand, stones, anchor bolts and nuts and curing of casted foundation, refilling & ramming of loose soil around foundation and disposal of loose dugged soil from site for Apparatus case Half.

2

7042

14084.02

... More
Supply, transportation to site, erection and concreting the base of RCC OFC/QUAD joint/route markers at the location of OFC/QUAD joints and route as per technical specification. (Inspection Authority: Consignee)

25

289

7237.75

... More
Supply of Digital multimeter (true RMS) for diagnosis & measuring parameter; Make:Fluke KYORITSU or Klein Tools. (Inspection Authority: Consignee)

2

12038

24077.18

... More
Supply and Installation of earth electrode, soldering/welding and nut bolt both, MS 09 flat to earth electrode and other end to Signal equipments as per requirements of Signalling in 25 KV A C electrified Area and as per SEM and as per technical specification. Note:Installation of earth electrodeincludes the construction of thesurrounding earth pit usingcontractor's own materials. (Inspection Authority: Consignee)

4

4905

19621.96

... More
G.I. Pipes with thread collars of 80mm nominal bore, specification IS:1239 medium grade make : TATA/JINDAL/BANSAL to be perforated after supply for required length. (Inspection Authority :Consignee)

50

722

36116.5

... More
Block Telephone (Complete with PTT handset) suitable to work with Block Panel & UFSBI of Deltron make. (Inspection Authority :Consignee).

60

11844

710695.2

... More
Pulling/drawing of OFC Cable with Nylon rope in the HDPE pipe as per technical specification.

2000

4

9080

... More
Cement concrete work for miscellaneous items ( MACLs /Apparatus Cases/LC Gates, etc) in the ratio 1 : 3 : 6, aggregate not exceeding 3 : 8 cm including excavation,raming, curing and 06 plastering with 1 : 4 cement - sand mixture complete with contractor's material including cement, sand, aggregate and curing of casted foundation, refilling & ramming of loose soil around foundation and disposal of loose dugged soil from site. The scope of works mainly includes making/strengthening/ reconditioning of foundation of Signal Posts ,Apparatus cases, LC gates , etc or at other associated signalling installations as per instruction of SSE incharge.

3

8342

25026.6

... More
Protection work of cable over boulder pitched / high cutting area, clvert, in yard, rocky, congested / residential area etc. using 100 mm nominal dia RCC/HDPE pipe and covering it 04 making continuous square block of 1:2:3 massionary work as per site condition. Minimum depth of 500 mm from surface label to be maintained after concreting at yard/residential area etc wherever possible. Depth not required on culvert and direct concreting can be made as mentioned above. All required materials i.e. RCC/HDPE pipe, cement, sand, aggregate, etc. will be supplied by the contractor.

400

293

117200

... More
Advanced Optical power meter 850/1300/1310/1490/1550/ 1625 mm calibrated wave lengths. Make: Stanley or Exfo or Yokogawa. Demonstartaion to be given at the time of supply. Along with this, 4 number FC Male to LC Females and 4 number LC Female to SC Male SM Optical Fiber Convertor Adapter to be supplied by contractor. (Inspection Authority: Consignee)

2

17404

34808.76

... More
Apparatus case half, as per RDSO Drg. No.RDSO /S /11507 with latest amendt. (Inspection Authority: Consignee)

2

12675

25350.54

... More
Splicing of 24F OFC with jointing kit and RCC chamber as per TS. OFC jointing kit will be supplied by Contractor. (Inspection Authority: Consignee)

4

9361

37444

... More
Supply of 'One QUAD' 2T VF transformer, impedance ratio 1120:470 or 600: 470 or 470: 470 as per specification No. IRS: TC - 22/76 or latest. The rating to be supplied will be decided by Engineer Incharge. (Inspection Authority: Consignee)

20

868

17379.4

... More
Relay, non AC immune, plug-in type, style QN1, DC neutral line, 24V DC, 8F/8B contacts. Front & back contacts metal to carbon, complete with plug board, retaining clip & connectors, confirming to BRS 930, IRS:S-34 & IRS:S-23 or latest. (Inspection Authority :RDSO)

100

4465

446533

... More
Taking the all types of cables inside station relay rooms, ASM's room, location huts, location boxes and junction boxes etc. and sealing of cable entry pit as per Technical specifications, complete with contractors's material.

1

17305

17305.33

... More
Supply & installation of RCC Emergency Control Socket Posts. Its includes 06 transportation to site,digging of pit and erection of Emergency post complete with socket and socket boxes ,as per TS and drawing. Wiring, testing and commissioning of the Emergency socket along side Railway Track and as per direction of Site Supervisor. (Inspection Authority: Consignee)

4

2406

9625.2

... More
Fixing of GI pipes with sockets / couplers, M.S. angle, MS Flat, nuts, bolts, etc. on 05 bridges/ culverts for cable protection and concreting of ends with brick masonry at both ends complete with contractor's own materials as per technical specifications. ( Only GI pipes as per requirement will be supplied against separate item of schedule)

50

260

13000



Evaluation Notes How It Works ?

Related Tenders

Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.