National Institute Of Biomedical Genomics Tender
Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.
National Institute Of Biomedical Genomics - NIBMG Tender
Eprocure
Opening Date3 Dec 2021
Closing Date24 Dec 2021
Tender Amount₹ 6,00,000
Costs
EMD
₹ 12,000Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2021_NIBMG_661168_1Bid Award Id
ViewTender No
NIBMG/ATM/2021-22/008Tender Authority
National Institute Of Biomedical Genomics ViewPurchaser Address
-Website
http://https://www.nibmg.ac.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
Supplying and filling in plinth with silver sand under floors, including watering, ramming, consolidating and dressing complete.
4.55
-
-
Demolishing brick work (in cement mortar) manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.
1.43
-
-
Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge.
0.47
-
-
Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III)derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from
natural sources)
4.43
-
-
Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer's specification
27.44
-
-
Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand.
18
-
-
Supplying and laying Polythene Sheet (150gm / sq.m.) over damp proof course or below flooring or roof terracing or in foundation or in foundation trenches.
50
-
-
Anti-termite treatment to the top surface of the consolidated earth within plinth walls with chemical emulsion by admixing chloropyrofos emulsifiable concentrates (1% concentration) with water by weight at the rate of 5 Litres per sq. m. of the surface before sand bed or sub-grade is laid. Holes upto 50 mm. to 75 mm. deep at 150 mm. centre to centre both ways shall be made with 12 mm, diameter mild steel rod on the surface to facilitate saturation of the soil with the chemical emulsion. The work shall be carried out as per specification described in para 6.4 of code IS- 6313 (part -II) 1981. (Mode of measurement will be per Sq.m of plan area of plinth treated.)
18
-
-
Treatment to the back filling of R.C.C. foundation with chemical emulsion by admixing chloropyrofos emulsifiable concentrate (1% concentration) with
water by weight at the rate of 7.5 ltr. per sq.m. of the vertical surface of the substructure of each side of the foundation. The work shall be carried out as per specification as described in para 6.3.1 of code IS- 6313 (part-II) 1981 (Mode of measurement will be per sq.m. of vertical area of foundation treated).
24
-
-
Providing and laying in position cement concrete excluding the cost of centering and shuttering - in fdn. and plinth. Grade M 10 [(1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 40 mm nominal size derived from natural sources)]
2.67
-
-
Providing and laying in position cement concrete excluding the cost of centering and shuttering - in fdn. and up to 5.0 mtr ht. from ground level Grade M 20 [(1:1½:3 (1 Cement: 1½ coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)]
9.5
-
-
Hire and labour charges for shuttering with centering and necessary staging up to 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor) 9 to 12 mm thick approved quality ply board shuttering in any concrete work
100
-
-
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete Thermo-Mechanically Treated bars of grade Fe-500D or more
Make: Tata/SAIL/RINL
1100
-
-
Brick work with common burnt clay F.P.S. (non- modular) 1st class bricks. Up to 1st floor level
Mortar: 1 cement : 6 coarse sand
16.8
-
-
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.
Size of Tile 600x600 mm
23
-
-
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor). With Cement Mortar 1:6, 12 mm thk. (external wall)
90
-
-
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor). With Cement Mortar 1:6, 20 mm thk. (internal walls)
72
-
-
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).
With Cement Mortar 1:4, 12 mm thk. (ceiling)
26.95
-
-
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
125.9
-
-
Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. Two coats of paint over one coat of one thinnable cement primer
125.9
-
-
Applying Exterior grade Acrylic primer of approved quality and brand on plastered or concrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface thoroughly, complete as per manufacturer's specification and as per direction of the EIC. in ground floor (Two or more coats)
90
-
-
Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of Engineer-in-Charge to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer. (Two coats) Super Protective 100% Acrylic Emulsion
90
-
-
Supplying, fitting and fixing steel rolling shutter profile type with 18 B.G . of approved type steel latch section 75mm wide, fitted with coil wire spring to necessitate the fitting of required Nos. of C.I. Pulleys on heavy type solid drawn seamless steel tube complete with locking arrangements both inside and outside specially built up side guide channels including providing a hood for the steel rolling shutter in the room, painting two coats of approved aluminium paint over a coat of red lead primer complete.
12
-
-
Supplying and laying true to line and level 20 mm / 25 mm. thick precast roof tiles made of cement conc. with stone chips as per approved strength and density set in 25mm avg. thick cement mortar (1:3) and filling up joint (3 mm wide) with cement sand mortar (1:1) applying cement slurry @ 1.75 kg per sq.m back of tiles and then setting close the precast tiles, finishing up the joints with slurry already laid and finally finishing the top surface including providing 150 mm. high skirting with the same tiles flushed with the inside surface of parapet wall, finishing the mouth of rain water pipes, curving etc. as necessary complete as per direction of the engineer-in-charge. (Levelling if necessary may be paid separately) (a) For 20 mm. thick precast tiles (cement 14.6 kg/ sq.m for under layer)
22.75
-
-
ELECTRICAL WORK
-
-
-
4CX10 sq.mm Al Armoured cable supply for feeding power from Substation.
220
-
-
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required for 4Cx10 SQMM AL cable
180
-
-
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required FOR 4CX10 SQMM ARMOURED AL CABLE
40
-
-
4 way double door TPN MS db ( Havells or equivallent make) supply and installation
1
-
-
PVC Conduit pipe (20 mm) supply and laying on roof structure
75
-
-
3 phase kwh meter supply and installation
1
-
-
32 A 4P MCB supply and installation
1
-
-
Supplying and making end termination with brass compression gland and aluminium lugs for PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV graded as required
2
-
-
Supply and laying of 80 mm GI pipe (Medium class)
20
-
-
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. Including supply and laying of GI strip 25mm x6 mm GI strip 5 mtr. length