Irrigation And Waterways Department Tender
... More
The Irrigation And Waterways Department has issued a formal invitation for competitive bids for Repairing Works Of Electrical Wiring System For Building Of Lower Damodar Irrigation Division Office At Singur Irrigation Campus in Hooghly, West Bengal, with an estimated contract value of Rs. 2,85,550. The bid opening date for this tender is 28-05-2025 and the last date for bid submission is 04-06-2025. Interested bidders for Irrigation And Waterways Department tender can download the important documents here to check the scope of work, eligibility criteria and technical requirements.
Irrigation And Waterways Department Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date28 May 2025
Closing Date4 Jun 2025
Tender Amount₹ 2,85,550
Costs
EMD
₹ 5,711Document Cost
Refer DocumentsTender Fee
Refer Documents
Summary
Repairing Works Of Electrical Wiring System For Building Of Lower Damodar Irrigation Division Office At Singur Irrigation Campus
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_IWD_853896_1Tender No
WBIW/EE-II/LDI/e-NIT-05/25-26Tender Authority
Irrigation And Waterways Department ViewPurchaser Address
-Website
http://https://wbtenders.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
... More
Distribution Wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in suitable size PVC casing-capping (Precision make) with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, incl. necy. PVC clips, fittings etc. to 5A 3 pin flush type plug socket with piano key type switch (Anchor make) fixed on sheet steel fabricated CRC MS switch board with bakelite/perspex (wall matching color) top cover of 3 mm thick flushed in wall by housing the board after cutting brick wall incl. necy. connection making earthing attachment, painting and mending good damages to building works [PVC
casing-capping and plug box both on surface] a) On Board
16
79
-
... More
Supply & Fixing 240 V 6 A Modular type switch (Brand approved by EIC) on existing GI Modular type switch board having top cover plate and making necessary connections as required
56
97
-
... More
Supply & Fixing 240 V 16 A Piano key type switch (Brand approved by EIC) on GI Modular type switch board having top cover plate and making necessary connections as required
48
141
-
... More
Supply & Fixing 240 V, 6A, 5 pin Modular type plug socket (Brand approved by EIC), without switch & plug
top, on existing GI Modular type switch board with top cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
35
143
-
... More
Supply & Fixing 240 V, 16 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and
switch, on existing GI Modular type switch board with top cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
95
96
-
... More
Supplying and fixing double door sheet steel (16SWG), powder coated cable end box for TPN DB horizontal / vertical enclosure with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish with nuts bolts etc incl. provision for earthing attachment 6 way horizontal
5
812
-
... More
Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch, on existing GI Modular type switch board with top cover plate and making necy. connections with PVC Cu
wire and earth continuity wire etc.
42
232
-
... More
Supplying & Fixing Industrial Plug & Socket board with 240 V, 20A, SPN & Earth Metal Industrial Plug socket & 20A Industrial top incl. S&F 20 A SP MCB breaking capcity 10kA (C- Curve) in SS enclosure fixed on wall and cecessary conection.
35
1077
-
... More
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection. 6-32 A L&T SP
45
190
-
... More
Fixing outdoor type fluorescent/SV/MV light fitting on pole including S&F 40 mm dia x 1.68 mts. long GI Pipe (ISI-Medium)bracket with 40 mmx10 mm thick, MS clamp etc. and providing wiring with 2x1/1.40 PVC insulated & sheathed wire (single core) partly in GI conduit & partly through above bracket from OH line to the fitting, without control switch, incl. making connections and painting
2
1668
-
... More
Supplying and Drawing 1.1 KV single core stranded 'FR'
PVC insulated & unsheathed single core stranded copper wire
(Brand approved by EIC) of the following sizes in the prelaid
polythene pipe and by the prelaid GI fish wire and making
necy. connection as required m)2 x 80/0.4 (10 sqmm)
135
235
-
... More
J) 2 x 84/0.3 (6 sqmm)
150
126
-
... More
Laying of cable as below, on existing Cable Tray and binding with
suitable size GI wire.i ) upto 50 Sqmm
40
13
-
... More
PVC casing-capping of size 25x12mm
70
32
-
... More
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts.
long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia
x 80 mm long GI bolts, double nuts, double washers incl. S &
F 15 mm dia GI pipe protection (1 Mts. long) to be filled with
bitumen partly under the ground level and partly above ground
level driven to an average depth of 3.65 Mts. below the ground
level as below: By TaTa medium GI pipe
5
1816
-
... More
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat
65 mm x 8 mm on wall having clearance of 6 mm from wall
including providing drilled holes on the busbar complete with
GI bolts, nuts, washers, spacing insulators etc. as required
2
376
-
... More
Connecting the equipments to earth busbar including S & F GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as
required and mending good damages (b) Stranded GI wire
(i) 7/14 SWG
125
19
-
... More
Earthing with Copper plate (610x610x3mm size) having weight of 9.84 Kg and 1 No. 25x5mm Copper strip (3.20 mt long) & 1 no. 6 sqmm PVC insulated stranded Copper wire (4 Mt long) incl. S & F 15 mm dia GI pipe (ISI-Medium) protection (4 mt. long) to be fillied with bitumen, partly under the ground level & partly above ground level to an average depth of 3.65 Mts. below the ground level and restoring the surface duly rammed incl. providing 3.0 mt long, 25 mm dia GI pipe (ISI-Medium) for periodic treatment, incl. providing masonery enclosure on the top of the earth electrode of overall size 86.36x86.36x46cm deep (below Ground level) complete with cemented brick work
(1:6) of 25 cm width, duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56x35.56cm with locking arrangement, GI reducer and treatment of soil by
using salt & charcoal or coke for plate electrode
4
12473
-
Evaluation Notes How It Works ?