Search from over 10,000+ business opportunities that have been announced from the biggest West Bengal tenders, e tender West Bengal, WB government tenders, and the Online Tender Notices posted on West Bengal e tenders to date. Find opportunities that have come in from multiple corporations, West Bengal government departments, State PSUs, and several Private companies from the state.

Gorkhaland Territorial Administration Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date25 Mar 2025
Closing Date9 Apr 2025
Tender Amount₹ 51,03,089 
Notes
Download

Costs

Summary

Gta/dhfws /niet-06(1stcall)/e-tender/

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supplying P.V.C. water storage tank of approved quality with closed top with lid (Black) - Multilayer (d) 2000 litre capacity PWD SOR: 37 / 6

1

10434

10434

... More
b) Plain Y,(ii) 110 mm. Dia.

3

223

669

... More
iii) Glazing clip.

7

50

350

35

158

5530

... More
25mm. thick damp proof course with cement concrete with stone chips (1:1.5:3) [with graded stone aggregate 10 mm nominal size] and admixture of water proofing compound as per manufacturer's specification followed by two coat of polymer based paint, (1st coat after 4 to 5 days of concrete laying and 2 nd coat just before brick masonry work) as directed (cost of water proofing compound & polymer based paint to be paid separately).( Chequering not required over concrete or painted surface).[Note: - Waterproofing as per item 9, polymer based paint as per item 8 (a) of subhead C of Section (C).PWD SOR: 47 / 1

5.92

190

1124.8

... More
Supplying, fitting & fixing UPVC pipes A- Type and fittings conforming toIS:13592-1992 with all necessary clamps nails, including making holes inwalls, floor etc. cutting trenches in any soil through masonry concrete structures etc if necessary and mending good damages including joining withjointing materails (Spun Yarn, Valamoid/Bitumen/M-Seal etc) complete.PWD SOR : 213 / 21A) UPVC Pipes:(ii) 110 mm. Dia.

22.1

251

5547.1

... More
(I) Cement concrete with graded stone ballast (40 mm size excluding shuttering) In ground floor(A) [Pakur Variety] Ground Floor(a) 1:3:6 proportion PWD SOR: 34 / 22

17.96

5247

94243.48

... More
125 mm. thick brick work with 1st class bricks in cement mortar (1:4) inground floor.PWD SOR: 16/16 a) in ground floor

164.99

728

120205.11

... More
II) in 1st Flr

101.7

134

13700.01

... More
(B) WALLWith Sand Cement Mortar (1:3) 15 mm thick & 2 mm thickcement slurry at back side of tiles using cement @ 2.91Kg/Sq.m & joint filling using white cement slurry @0.20kg/Sq.m.(a) Area of each tile upto 0.09 Sq.m(ii) Other than Coloured decorative including white

97.65

715

69819.75

... More
(ii) Plain Tee,110mm

12

85

1020

... More
iii) Cleat angle ( Non-annodized).

5.4

263

1420.2

... More
Rendering the Surface of walls and ceiling with White Cement baseWATER PROOF wall putty of approved make & brand.(1.5 mm thick) Inner WallsPWD SOR: 198 / 5I) in Gr Flr

516.2

122

62976.4

... More
(a) Priming one coat on steel or other metal surface with synthetic oilbound primer of approved quality including smoothening surfaces by sand papering etc.PWD SOR: 200 / 1a

59.1

29

1713.9

... More
Brick work with 1st class bricks in cement mortar (1:6) PWD SOR: 15/8 a) in foundation & plinth

21.48

5380

115565.41

... More
Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work) (a) With earth obtained from excavation of foundation PWD SOR: 1/3

23.4

77

1814.44

... More
Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening andremoval of loose rust (if necessary), cutting to requisite length, hooking andbending to correct shape, placing in properposition and binding with 16gauge black annealed wire at every intersection, complete as per drawingand direction. PWD SOR: 43/40III.Other than SAIL/ TATA/RINL (a) For works in foundation and upto roof of ground floor/upto 4 m

6.18

53503

330705.75

... More
Anodised aluminium butt hinges of approved quality manufactured from extrudedsection conforming to I.S. specification (I.S. 205/66) and fitted and fixed with cadmium plated screws:PWD SOR: 145 / 29 (vii) 100 x 75 x 4.0mm

126

93

11718

... More
iii) 25mm dia

2

912

1824

... More
Construction of septic tank of different capacities as per approved drawing with 1stclass brick work in cement mortar (1:4) including two 560 mm dia. R.C.C. manholecover(heavy type)of approved make supplied, fitted and fixed in the 100mm thickR.C.C (1:1.5:3) top slab with necessary fittings, 20mm thick cement plaster (4 : 1)with neat cement finish to the internal surfaces and 15 mm thick cement plaster (4 : 1)to outside wall upto 200 mm below G.L floor finished with 25 mm thick grey artificialstone over 100 mm thick R.C.C(1:1.5:3) bottom slab including supplying, fitting and fixing all necessry specials, fittings, S.W. tees, C.I. foot rest etc. including excavationearth in all sorts of soil, shoring, bailing out and pumping out water as necessary,ramming, dressing the bed and fefilling the sides of the tanks with earth, removingspoils, filling up the chamber with clear water, removing foreign materials from thechamber and including constructing attached inspection pit as per approved drawing and connecting all necessary pipes, joints etc. with internal plaster work and artificialstone flooring is to be done with admixture of water proofing compound @ 0.5% byweight of cement with all costs of labour and materials. Note:- (i) Finished level of Septic Tank should be 400 mm. from Ground Level. (ii) Height of 50 mm.Ventilation pipe &Mosquito proof mesh, should be follwed as per IS:2470,Part- I.Payment will be made separetly on the basis of actual height based on relevant I.S.Code.(ii) For 20 usersA) With Pakur variety. (SAIL/TATA/RINL)PWD SOR: 88 / 3 - 7th Corri

1

48205

48205

... More
(B) Under ground(ii) 110 mm dia.

26

84

2184

... More
Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns,lintels curved or straight including fitting, fixing and striking out aftercompletion of works (upto roof of ground floor)(When the height of a particular floor is more than 4 m the equivalent floor height shall be taken as 4 m and extra for works beyond the initial 4 m ht.shall be allowed under 12 (e) for every 4 m or part thereof)Steel Shuttering 9 to 12 mm thk approved quality plyboard shuttering in any concrete worksdirection of Engineer-In-Charge.PWD SOR: 42 / 36a) in foundation and Gr Flr

473.8

369

174832.2

8

205

1640

... More
Surface Dressing of the ground in any kind of soil including removing vegetation inequalities not exceeding 15 cm depth and disposal of the rubbish within a lead upto 75 m as directed.PWD SOR: 1/1

168

10

1680

... More
Supplying, fitting and fixing PVC pipes of approved make of Schedule 80(medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories,specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder batsclamps, including cutting pipes, making threads,fitting, fixing etc.complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paintin any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separatepayment will be made for accesories, specials. Payment for painting willbe made seperately) PWD SOR: 12 / 19 (I)(a) For Exposed WorkPVC Pipes1. 40 mm

25

292

7300

... More
Supplying, fitting and fixing 10 litre P.V.C. low-down cistern conforming toI.S. specification with P.V.C. fittings complete,C.I. brackets including twocoats of painting to bracket etc.PWD SOR: 36 / 2

4

1015

4060

... More
iv) 150mm long x 10mm dia. bolt.

10

63

630

... More
III) in 2nd Flr

157.2

46

7312.94

... More
Labour for punching hole in plastic water storage tank upto 50 mm dia.PWD SOR: 38/13

2

19

38

... More
Labour for fitting and fixing U.P.V.C. pipes for above ground workincluding cost of jointing materials etc. fitting and fixing all necessaryspecials, cutting pipes, cutting holes in walls or R.C. floor where necessary and mending good all damages excluding the cost of masonry or concretework, if necessary, but includingthe cost and fitting and fixing holder bat clamps (any floor) or for underground work including cutting trenches upto1.5 metre and refilling the same complete as perdirection of the Engineerin- charge. (Payment will be made on centre line measurement of the totalpipeline including specials. PWD SOR: 74 / 24(A) Above ground(ii) 110 mm dia

22

57

1254

... More
III) in 2nd Flr

14.6

138

2025.17

... More
ii) Mullion.

1.8

339

610.2

... More
Artificial stone in floor, dado, staircase etc with cement concrete (1:2:4) with stone chips, laid in panels as directedwith topping made with ordinary or white cement (asnecessary) and marble dust in proportion (1:2) includingsmooth finishing and rounding off corners including rakingout joints or roughening of concrete surface and applicationof cement slurry before flooring works using cement @ 1.75 kg/sq.m all complete including all materials and labour. In ground floor.3 mm. thick topping (High polishing grinding on this item isnot permitted with ordinary cement).Using grey cementPWD SOR: 48 / 6(ii) 25 mm. thick III) in 2nd Flr

117.9

281

33159.38

... More
Supplying, fitting and fixing towel rail with two brackets. (a) C.P. over brass(i) 25 mm dia. and 450 mm long PWD SOR: 82 / 22

4

384

1536

... More
i) Iron hasp bolt of approved quality fitted and fixed complete (oxidised) with16mm dia rod with centre bolt and round fitting.PWD SOR : 141 / 10(b) 250mm long.

21

159

3339

... More
Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand.PWD SOR: 14 / 1

138.64

361

50049.04

... More
Supplying, fitting & fixing of partly glazed partly panelled or fully glazed single leaf Aluminium swing door of all aluminium sections viz door frame ( top and side frame), shutter( top rail, bottom rail, lock rail, door vertical) , glazing clip made of Aluminium Alloy Extrusions conforming toIS: 733-1983 and IS: 1285-1975, annodized conforming to IS:1868-1983, fitted with all other accessories viz. EPDM gusket,cleat, anglescrews etc. including labour charges for fitting and fixing of aluminiumdoor with doorspring,/aluminium hinges, glass / Panel board allcomplete as per architectural drawings and direction of Engineer-incharge.( Excluding cost of glass/ panel board, door spring/ Al hinges, doorcloser, door stoper, handle, tower bolt and locking arrangment etc)10-12 Micron thickness Annodizing filmNatural whitePWD SOR : 246 / 16

412

385

158620

... More
Supplying,fitting and fixing approved brand 32 mm dia.P.V.C. waste pipe,with PVC coupling at one end fitted with necessary clamps.(iii) 900 mm long PWD SOR: 43 / 10

10

75

750

... More
(A) Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity) PWD SOR: 2/4

52.68

936

49319.54

... More
xv) Vent Cowl,110mm

1

33

33

... More
(c) 15 mm thick plasterI) in Gr Flr

418.6

148

62250.01

... More
Supplying profiles of required section made of Aluminium AlloyExtrusions conforming to IS: 732-1983 and IS: 1285- 1975; Annodized(with required film thickness and specified colour / natural) matt finished conforming to IS: 1868-1983 for fabrication of composit door, sliding &casement windows, partitions, formed of basic sections of any ISIembossed / certified make and brand as per direction of Engineer - In-Charge. (Payment will be made on finished length of the work).(A) In 10-12 Micron thickness Annodizing filmPWD SOR: 233 / 1I) Natural whiteh) Louvered windowi) Top, bottom and side member

12

183

2196

... More
L.cess @ 1%

1

50526

50526

... More
Pre-Constructional Anti-termite measures: (a) Anti termite treatment to bottom surface ( in case of masonry foundation and basements) and the sides (upto a height of 300 mm. from bottom) of the excavation trenches with chemical emulsion by admixing chloropyrofos emulsifiable concentrates (1% concentration) with water by weight at the rate of 5 Litres per sq. m. area. The work shall be carried out as per specification described in 6.2.1. of code IS- 6313 (part -II) 1981. (Mode of measurment will be the plan area of foundation treated.) PWD SOR: 5/10

129.86

110

14284.6

... More
II) in First Floor

3.8

9986

37950.14

... More
Supplying, fitting and fixing pillar cock of approved make. a) (i) CP Pillar Cock - 15 mm. (Equivalent to Code No. 507 & Model - Tropical / Sumthing Special of ESSCO or similar brand). PWD SOR: 45 / 19

4

555

2220

... More
In ground floor (Plinth Protection)

64.8

273

17690.4

... More
b) in superstructure Gr Floor

30.19

5590

168786.55

... More
18 mm. to 22 mm. thick, kota stone slab set in 20 mm thick(avg) cement mortar (1:4) in floor, stair & lobby includingpointing in cement slurry with admixture of pigment matchingthe stone shade, including grinding & polishing as perdirection of Engineer - in - charge to match with the existingwork. [Slurry for bedding @ 4.4 kg/Sq.m and pointing @2.0kg/Sq.m]PWD SOR: 54 / 17

78.31

1024

80189.44

... More
II) in 1st Flr

463.7

122

56571.4

... More
Labour for Chipping of concrete surface before taking up Plastering work.PWD SOR: 182 / 1

213.98

21

4493.58

... More
extra rate for using water proofing and plasticising admixture @ 0.2% byweight of cement (or at manufacturer's specified rate) for concrete of various grades.PWD SOR: 45 / 9

193.68

1285

248878.8

... More
A) Painting with best quality synthetic enamel paint of approved makeand brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary :(b) On steel or other metal surface With super gloss (hi-gloss)(iv) Two coats (with any shade except white)PWD SOR: 200 / 2A

59.1

79

4668.9

... More
c) Second Floor

3.07

6504

19977.14

... More
Supplying, fitting and fixing C.I. round grating(i) 100 mmPWD SOR: 67/18

9

62

558

... More
d) Shoe,(ii) 110 mm. Dia

3

111

333

... More
Labour charge for fabrication and installation of composite door,window, partitions made from annodized extruded alloy aluminiumsections for the following units:PWD SOR: 239 / 2iv ) Fixed glazing.

3.2

768

2457.6

... More
Applying Exterior grade Acrylic primer of approved quality and brandon plastered or cencrete surface old or new surface to receivedecorative textured (matt finish) or smooth finish acrylic exterioremulsion paint including scraping and preparing the surface throughly,complete as per manufacturer's specification and as per direction of theEIC.(b) Two Coats PWD SOR: 196 / 8I) in Gr Flr

200.3

45

9033.53

... More
Supplying, fitting and fixing E.W.C. in white glazed vitreous chinaware ofapproved make complete in position with necessary bolts, nuts etc.(a) With 'P' trapPWD SOR: 79 / 2

4

1421

5684

... More
b) First Floor

31.81

6409

203898.28

... More
d) Treatment to the back filling of R.C.C. foundation with chemical emulsion by admixing chloropyrofos emulsifiable concentrate (1% concentration) with water by weight at the rate of 7.5 ltr. per sq.m. of the vertical surface of the substructure of each side of the foundation. The work shall be carried out as per specification as described in para 6.3.1 of code IS- 6313 (part-II) 1981 (Mode of measurement will be per sq.m. of vertical area of foundation treated). PWD SOR: 6/10

49.98

137

6847.26

... More
Supplying fitting and fixing in position approved P.V.C. door frame (Matt finish)made of extruded P.V.C. multichamber hollow section having dimensions 60mm x50mm x 2mm (+/-0.2mm), horizontal section will be joined with vertical sectionby galvanised steel screws after inserting two number steel brackets reinforcement making suitable space for placing hinges, one steel tube 40mm x20mm x 1.20 mm will be inserted on one full vertical side of the frame (hinge side)as reinforcement, the frame will then be fixed in the opening with the help ofP.V.C. expandable fastner/wooden gutties and galvanised steel screws includingcost of all materials and labour, hire charges of tools and appliances, carriage ofall materials, taxes and all other incidental charges complete. PWD SOR: 117 / 8

44.55

279

12429.45

... More
II) in 1st Flr

168.2

97

16434.82

... More
(b) Stoneware single T or Y junction(ii) 150 mm

4

447

1788

... More
II) in 1st Flr

362

152

55281.02

... More
Supplying, fitting and fixing liquid soap containerPWD SOR: 82/17

5

188

940

... More
xi) Door Bend (T.S.)(b) 110 mm

15

147

2205

... More
III) in 2nd Flr

32.4

122

3952.8

... More
Providing, fitting and fixing in position, medium density fibre board conformingto IS: 12406-1988 for plain and IS: 14587-1998 for prelaminated made of wood fibre bonded with Urea formaldehyde for interior grade and PhenolFormaldehyde for exterior grade conforming to per IS:848-1974 as per approved make and brand as per direction of Engineer-inCharge.C) Both side decorative lamination(II) Interior Grade(ii) 12mmPWD SOR: 177 / 13 (c )I) in Gr Floor

10.7

880

9416

... More
Construction of circular soak well 2.5 metre deep in all types of sandy soils with drybrick work upto 1.6 metre from the bottom having 150 mm intermediate cement brickwork (1:4) band all round and cement brick work (1:4) upto 0.90 metre from top with20mm thick cement plastering (1:4) to inside face upto the depth of cement brickwork, 15mm thick cement plaster (1:4) on outer face from top of the well upto G.L.and 6 mm thick cement plaster (1:4) on top of the R.C.C. cover slab including fillingbottom 1.00 metre of inside of the wellwith brick metal (50 mm to 63 mm size) including R.C.C. cover slab of 100 mm thick withcement conc (1:1.5:3) with stonechips with necessary reinforcement and shuttering including one 560 mm dia. R.C.C.manhole cover (heavy type)of approved make supplied, fitted and fixed in the cover slab with necessary fittings, making nacessary arrangements for pipe connections,excavation of well including shoring, dewatering and removing the exess earth fromthe premises as per direction complete in all respect with all costs of labour andmaterials.PWD SOR: 89 / 4 - 7th CorriWith 250 mm thick dry brick work and 250 mm thick cement brick work (1:6) and1.00m inside dia.(SAIL/TATA/RINL)(Other than SAIL/TATA/RINL)

1

16627

16627

... More
(d) (i) Chromium plated angular Stop Cock with wall flange (Equivalentto Code No. 5053 & Model - Florentine of Jaquar or similar brand).

8

815

6520

... More
c) in First Floor

29.48

5701

168089.36

... More
Supplying, fitting & fixing 1st quality Ceramic tiles in wallsand floors to match with the existing work & 4 nos. of keystones (10mm) fixed with araldite at the back of each tile &finishing the joints with white cement mixed with colouringoxide if required to match the colour of tiles includingroughening of concrete surface, if necessary or by syntheticadhesive & grout materials etc.PWD SOR: 64 / 35(A) FloorWith Sand Cement Mortar (1:4) 20 mm thick & 2 mm thickcement slurry at back side of tiles using cement @ 2.91Kg/Sq.m & joint filling using white cement slurry @0.20kg/Sq.m. (a) Area of each tile upto 0.09 Sq.m (ii) Other than Coloured decorative including white

18.73

713

13354.49

... More
Supplying, fitting and fixing White Vitreous China Sink in position on C.I. brackets including two coats of painting of brackets. (b) Laboratory sink with rim and overflow (i) 450 mm X 300 mm X 150 mm PWD SOR: 42 / 5(b)(i)

6

2381

14286

... More
Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed andraking out joints including throating, nosing and drip course,scaffolding/staging where necessary (Ground floor).[Excludingcost of chipping over concrete surface]PWD SOR: 189 / 1 (i) With 1:6 cement mortar(b) 20 mm thick plaster I) in Gr Flr

200.3

171

34387.5

... More
Constructing Inspection pit of inside measurement 600mm X 600mm X upto 600mm(depth) with 250 mm thick 1st. class brick work in cement mortar (1:4) on all sides,bottom of the pit consisting of 100 mm thick cement concrete (1:3:6) with stone chipsover a layer of jhama brick flat soling, 15 mm thick (1:4) cement plaster to insidewalls and out-side walls upto G.L. and 20 mm.thick (1:4) plaster to bottom of the pit,providing necessary invert with cement concrete (1:3:6) with stone chips as perdirection, neat cement finishing to entire internal surfaces, top of the pit covered with 100 mm thick R.C.C. slab (1:1.5:3) with stone chips and necessary reinforcements upto 1% and shuttering including 6 mm thick cement plaster (1:4) in all externalsurfaces of the slab and one 560 mm dia. R.C.C. manhole cover of approved make supplied, fitted and fixed in the slab with necessary fittings, necessary earthwork inexcavation in all sorts of soil, filling sides of the pit with earth and removing spoilsafter work complete in all respect with all costs of labour and materials.i) With Pakur variety. (SAIL/TATA/RINL)PWD SOR: 87 / 1 (7th Corri)

1

7253

7253

... More
Supplying, fitting and fixing CPVC (Chlorinated Polyvinyl Chloride) pipes of approved make conforming to IS-15778: 2007 . with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple,longscrew, reducing socket, reducing tee, short piece etc.fitted with holder bats clamps, including cutting pipes,fitting, fixing etc. complete in all respect including costof all necessary fittings as required,jointing materials inany position above ground. (Payment will be made onthe centre line measurements of total pipe line includingall specials. No separate payment will be made foraccesories, specials.(b) For Concealed Work(i) CPVC Pipes Class-1,SDR-11 PWD SOR: 29 / 1(b)15mm

6

140

840

... More
(I) Cement concrete with graded stone ballast (40 mm size excludingshuttering)In ground floor (A) [Pakur Variety]Ground Floor(a) 1:3:6 proportion PWD SOR: 34 / 22

1

5247

5247.41

... More
II) in 1st Flr

6.3

2301

14496.3

... More
Supplying,fitting and fixing approved brand P.V.C. CONNECTOR white flexible, with both ends coupling with heavy brass C.P. nut, 15 mm dia.(ii) 450 mm long PWD SOR: 43 / 9

4

82

328

... More
xvi) Pipe Clip,110mm

22

21

462

... More
Protective and Decorative Acrylic exterior emulsion paint of approvedquality, as per manufacturer's specification and as per direction ofEngineer-in-Charge to be applied over acrylic primer as required. Therate includes cost of material, labour, scaffolding and all incidentalcharges but excluding the cost of primerSuper Protective 100% Acrylic Emulsion Two CoatsPWD SOR: 197 / 17I) in Gr Flr

200.3

97

19429.1

... More
Collapsible gate with 40mm x 40mm x 6mm Tee as top and bottomguide rail, 20mm x 10mm x 2mm vertical channels 100mm apart infully stretched position 20mm x 5mm M.S. flats as collapsiblebracings properly rivetted and washered including 38mm steelrollers including locking arrangements, fitted and fixed in positionwith lugs set in cement concrete and including cutting necessaryholes, chasing etc. in walls, floors etc. and making good damagescomplete.In ground floor(Payment will be made on the area of the gate covered by twoguard rails and two extreme channels) PWD SOR: 106 / 18

8.6

4330

37238

... More
(a) M.S.or W.I. Ornamental grill of approved design jointscontinuously welded with M.S, W.I. Flats and bars of windows,railing etc. fitted and fixed with necessary screws and lugs in groundfloor.(i) Grill weighing above 10 Kg./sq.mtr and up to 16 Kg./sq. mtrPWD SOR: 104 / 13I) in Gr Floor

3.2

9888

31641.6

... More
(ii) With 1:4 cement mortar,(c) 10 mm thick plasterI) in Gr Flr

97.6

130

12757.3

... More
II) in 1st Flr

168.2

45

7705.24

... More
ii) 20mm dia

4

657

2628

... More
III) in 2nd Flr

17.8

156

2789.44

... More
Neat cement punning about 1.5mm thick in wall, dado, windowsill, floor etc.NOTE:Cement 0.152 cu.m per100 sq.m.PWD SOR: 192 / 15

29.3

32

959.28

... More
viii) 8mm thick coloured / tinted / smoke glass.

14

907

12698

... More
ii) Louvered Section.

5.4

658

3553.2

... More
Anodised aliminium D-type handle of approved quality manufactured fromextruded section conforming to I.S. specification (I.S. 230/72) fitted and fixed complete:(a) With continuous plate base (Hexagonal/ Round rod)(iv) 125 mm grip x 10 mm dia rod. PWD SOR : 145 / 30

42

95

3990

... More
Supplying and laying Polythene Sheet (150gm / sq.m.) over damp proof course or below flooring or roof terracing or in foundation or in foundation trenches. PWD SOR: 47 / 3

100.85

24

2420.4

... More
PVC Door Shutter-37 mm thickSupplying fitting and fixing P.V.C. door shutter of approved quality & shade inposition, the style & rail of the P.V.C. door shutter will be made of rigid P.V.C.multicavity hollow chamber of suitable size and section with 2.0 mm (+/-0.2 mm) wall thickness, the section will have 2nos. built in beads, horizontal & verticalsection shall be fixed to each other by self tapping screws and 2 nos. of solid plastic or M.S. tubular galvanised brackets of length 200mmx80mm andother100mmx100mm both 1.20 mm in each corner of the shutter frame forplacing hinges. Polymer based multicavity hollow section of 105 mm x37mm with2.0 mm (+/- 0.2 mm) wall thickness will be fitted in the middle as lock railreinforced by solid polymer bar of 200 mm long at both ends abd screws fromboth sides. The section frame will then be fitted in by PVC panels of size 100mmx20 mm with wall thickness of 1.2 mm (+/- 0.2 mm) and 2 nos. of 6 mm diaand screws from both sides 6mm dia brightrod will be inserted horizontally withboth side check and nut system and stretches where fixing of hinges / hasp bolt /tower bolt / door ring are required to be strong enough to with stand wear andtear. The rate is inclusive of cost of all materials, labour, and hire of tools andplants and appliencies. Carriage of all materials taxes and all other incidentalcharges complete.The rate is exclusive of cost of hinges, hasp bolt, towerbolt,door ring etc. In ground floor.PWD SOR: 133 / 26I) in Gr Flr

7.9

2287

18067.3

... More
c) In 2nd Floor

27.02

405

10941.08

... More
III) in 2nd Flr

157.2

98

15471.62

... More
Supplying,fitting & fixing of 2-Track / 3-Track Aluminium slidingWindow of all Aluminium sections viz. window frame (top,bottom & sideframe), shutter (top, bottom, side & interlock member) made of aluminium alloy extrusions conforming to IS 733-1983 & IS 1285-1975, annodisedconforming to IS 1868-1983, fitted with all other accessories viz. PVCroller, EPDM gasket, maruti lock, screws etc. including labour charges for fitting & fixing of aluminium 2-track/3-track sliding window withfixing of glass (excluding cost of glass) all complete as per architectural drawings and direction of Engineer-in-charge.10-12 Micron thicknessAnnodizing filmNatural whiteFor 2-Track window : Members for Bottom frame @ 0.875 Kg per Mtr.and for Top and Side frame @ 0.778 Kg per Mtr. and for shutter Bottom and Top member @ 0.472 Kg per Mtr., Style side member @ 0.493 Kgper Mtr. and Interlock member @ 0.612 Kg per Mtr.For 3-Track window : Members for Bottom frame @ 1.233 Kg per Mtr.and for Top and Side frame @ 1.067 Kg per Mtr. and for shutter Bottomand Top member @ 0.472 Kg per Mtr., Style side member @ 0.493 Kgper Mtr. and Interlock member @ 0.612 Kg per Mtr.PWD SOR: 245 / 15

176.2

448

78937.44

... More
v ) Louvered window.

1.8

730

1314

... More
Wash basin vitreous china of approved make (without fittings) supplied,fitted and fixed in position on 75mm X 75 mm X 75 mm wood blocks and C.I. brackets including two coats of painting of C.I. brackets (ii) 550 mm X 400 mm size PWD SOR: 41 / 1 (ii)

7

1383

9681

... More
Supplying,fitting & fixing granite slab 15mm to 18mm thick infloor, lobby, stair, landing and treads etc. over 20mm (avg)thick base of cement morter (1:2) laid with white cement slurry@ 4.40Kg per Square meter before placing of granite andjointed with white cement slurry @ 2.0 Kg per square meterwith necessary pigments and complete as per direction ofEngineer-in-charge including cost of all materials, labours,curing and roughening of concrete surface complete.In ground floor(c) Area of each Granite slab above 1.00 Square meter.

2.04

3021

6162.84

... More
G.S.T @18%

1

770730

770730

... More
Base of DG set (Civil Works)

1

40044

40044

... More
Supplying, fitting and fixing 15 mm swan neck tap with left & right hand operating nob with aerator (Equivalent to Code No. 510, 510(A) and Model - TROPICAL / SUMTHING SPECIAL of ESSCO or similar brand). PWD SOR: 44 / 16

8

811

6488

... More
Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground flooras per relevant IS codes (i) Pakur Variety) a) Gr Flr and Foundation

62.99

6314

397774.29

... More
Extra rate for using water proofing and plasticising admixture @ 0.2% byweight of cement (or at manufacturer's specified rate) for concrete of various grades.PWD SOR: 45 / 9

39.3

119

4676.7

... More
Anodised aluminium barrel / tower / socket bolt (full covered) of approvedmanufactured from extruded section conforming to I.S. 204/74 fitted and fixed with cadmium plated screwsPWD SOR : 144 / 26 (vii) 225mm long x 10mm dia. bolt.

21

84

1764

... More
Supplying, fitting and fixing Closet seat of approved make with lid and C.P.hinges, rubber buffer and brass screws complete.PWD SOR: 81 / 10(a) E.W.C. (ii) Plastic (hallow type) white

4

380

1520

... More
(b) For Concealed Work1. 15mm

45

137

6165

... More
Extra cost of labour over grey artificial stone for (i) ChequeringPWD SOR: 49 / 8

117.9

15

1768.5

... More
Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete (a) Depth of excavation not exceeding 1,500 mm. PWD SOR: 1/2

117.01

119

13955.78

... More
M.S. gate of Jail type as per approved design made of strong M.S.frame work, intermediate stiffeners and round / square bars orangles. M.S. sheet (not less than 14 gauge) gussets, cleats etc.including necessary riveting, bolting, welding, locking and hanging arrangements, fitting and fixing complete as per direction of theEngineer-in -charge.PWD SOR: 105 / 16III) in 2nd Flr

0.9

10292

9263.53

... More
( c) in second floor

0.29

54463

15739.98

... More
Acrylic Distemper to interior wall, ceiling with a coat of solvent based interior grade acrylic primer (as per manufacturer's specification) including cleaning and smoothning of surface.PWD SOR: 195 / 7

1012.3

70

70861

... More
(b) in first Floor

3.12

53983

168482.82

... More
g) Fixed glazingi) Top, bottom and side member

7.2

321

2311.2

... More
Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992(A) (i) Single Socketed 3 Meter Length(b) 110 mmPWD SOR: 68 / 23

48

292

14016

... More
c) Bend 87.5 degree(ii) 110 mm. Dia.

3

140

420

... More
Supplying,fitting and fixing 32 mm dia. Flush Pipe of approved make withnecessary fixing materials and clamps complete.i) Polythene Flush PipePWD SOR: 81 / 11

4

155

620

... More
II) in 1st Flr

168.2

175

29549.38

... More
Supplying bubble free float glass of approved make and brandconforming to IS: 2835-1987. PWD SOR: 243 / 9i) 4mm thick clear glass.

24.1

398

9591.8

... More
Supplying, fitting and fixing Peet's valve fullway gunmetal standardpattern best quality of approved brand bearing I.S.I. marking with fittings(tested to 21 kg per sq. cm.).PWD SOR: 4/I-4i) 15mm dia

2

521

1042

... More
Supplying, fitting and fixing with cement jointing (3:1) salt glazed stoneware pipe including excavation of earth upto 1.50 metre depth in all sorts of soil both mixed or unmixed and refilling (but excludingconcreting at bottom and sides).(iii) 150 mmPWD SOR: 66 / 16(iii)

42

334

14028

... More
Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992PWD SOR: 70 / 23viii) Double Y with Door(b) 110 mm

2

345

690

... More
Supply fitting and fixing Fire Exyinguisher Conforming to ISI marked ( IS 15683:2006) ABC type fire extinguisher stored pressure type of 6 kgs. Capacity , with initial filling in brand new cylinder with poder coated finish , fitted with gun metal union , discharge hose , wall mounting bracket and suitable sinage etc. complete ( Make: Fire Shield / New age / De Flame / Andex or equivalent ). A level should be pasted on the body of the Extinguisher duly signed & stamped by the Agency stating 1. Date of Installation 2. Date of Expiry/ Date of next refilling.( warranty card need to be submitted )

2

3356

6712.52

... More
a) Plain Tee,(ii) 110 mm. Dia

3

172

516

... More
b) in first floor

155.33

740

115031.18

... More
Supplying, fitting and fixing Stainless Steel railing consist of 38mmdia and 900mm height vertical balustrade at every two alternativesteps, 50mm dia top rail, 3 (three) nos 19mm dia horizontalStrainless steel pipe and base/cover plate with Strainless Steel GRADE 304 containing 7.5% nickle (Interior Grade) Brushed/Matfinish, complete as per direction of the Engineer-in-charge.Weight of Strainless Steel railing per metre 6.5 Kg (approx)PWD SOR: 109 / 22

6

9077

54462

... More
Design, Fabrication, Supply, Delivery (factory to health facility) and Fixing of Vinayl Printed Signage/Display board ( Size of board 4 X 5 sqft - 1 nos. .) , fabricated with 16 SWG rectangular MS angle / flat iron structure. Facia to be made of 1.5 mm ACP sheet and Logo, Color,lettering style etc. will be made as per approved specification which is to be digitally printed on Vinayl sheet by computerized inscription. Vinayl printed sheet to be fixed on ACP sheet. Ready signage to be fixed on wall/roof by 50x50 mm angle iron or as per site requirement incl. The matter is to be done as per approved specification. Non-Schedule. As per rate analysis.

1

8680

8680

... More
c) in second floor

5.21

752

3920.84

... More
Supplying, fitting and fixing with cement jointing (3:1) with jute gasketsoaked in cement mortar PWD SOR: 67/17(a) Stoneware bend(iii) 150 mm

4

350

1400

... More
III) in 2nd Flr

157.2

179

28245.7

... More
d) in 2nd Floor

18.33

5812

106548.81

... More
II) in First Floor

6.9

894

6168.6

... More
Supplying, fitting and fixing bib cock or stop cock. PWD SOR: 6 / 7(a) (i) Chromium plated Bib Cock short body (Equivalent to Code No. 511& Model - Tropical / Sumthing Special of ESSCO or similar brand).

9

539

4851

... More
b) in First Floor

286.26

387

110782.62



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.