District Magistrate Tender
... More
The DM has issued a formal invitation for competitive bids for the District Magistrate project, for Installation Of Solar Spot Drinking Water in Cooch Behar, West Bengal, with an estimated contract value of Rs. 4,54,163. The bid opening date for this tender is 03-11-2026 and the last date for bid submission is 17-11-2026. Interested bidders for District Magistrate tender can download the important documents here to check the scope of work, eligibility criteria and technical requirements.
District Magistrate - DM Tender - WB Tender
Opening Date3 Nov 2026
Closing Soon17 Nov 2026
Tender Amount₹ 4,54,163
Costs
EMD
₹ 9,083Document Cost
Refer DocumentsTender Fee
Refer Documents
Summary
Installation Of Solar Spot Drinking Water
Description
Installation Of Solar Spot Drinking At Jirati Shalbari Pry School Within Salbari -i I Gp Under Tufanganj-ii Panchayat Samity
Contact
Tender Id
2026_DMCB_5082928_3Tender No
08 (2ND CALL) OF 2026-27 OF THE EXECUTIVE OFFICERTender Authority
District Magistrate ViewPurchaser Address
-Website
https://wbtenders.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
... More
1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
0.703125
9122
6414.1
... More
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
2.61425
10473
27381.13
... More
STEEL REINFORCEMENT Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.
0.201686125
124007
25010.67
... More
Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete
18.31
454
8313.84
... More
CEMENT PLASTER WITH A FLOATING COAT OF NEAT CEMENT 12 mm cement plaster finished with a floating coat of neat cement of mix : 1:4 (1 cement: 4 fine sand)
7.35
492
3621.57
... More
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
0.73515
154807
113806.53
... More
Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 90 metre depth below ground level. All types of soil 300 mm dia
30
819
24584.4
... More
Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. 23.3.1 100 mm nominal size dia
30
778
23353.2
... More
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
1000
12
12740
... More
Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of:100 mm dia
1
259
259.48
... More
Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineerin charge.
0.5
2349
1174.66
... More
Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete.23.14.1 100 mm clamp
1
2213
2213.15
... More
Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of useable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by “V” notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, including disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge
3
1256
3769.05
... More
Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I) 100 mm dia
1
306
306.95
... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.25 mm nominal dia Pipes
6
411
2469.06
... More
Providing and fixing PTMT bib cock of approved quality and colour 15 mm nominal bore, 90 mm long, weighing not less than 93 gms
3
227
683.43
... More
Constructing soak pit 1.20x1.20x1.20 m filled with brick bats including S.W. drain pipe 100 mm diameter and 1.20 m long complete as per standard design.
1
3346
3346.36
... More
Solar Module: Supply, transport, installation and commissioning of lSI marked as per IS 14286 and IEC 61853(1). 61730(1&2), 61710 certified Solar Module of Multi crysta lin elM anocrvs tilIIine/ Monocrystalline PERC/bifacial cell with min. efficiency of 15% and fill factor more than 70%, laminated between sheet of -Ethylene Vinyl Acetate (EVA) and high transmissivity .3.2/4: mm tempered glass, framed in anodized aluminium frame .The power output of individual PV modules used in the PV array, under STC, should be a minimum of 300 Watt peak, with adequate provision for measurement tolerances.Modules supplied with the SPV system should have warranty for output wattage, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. Necessary test certificate also to be supplied. (As per direction of EIC)
c)For 1 HP Off-grid Solar Water Pumping System with Monocrystalline/ Monocrystalline PERC/bifacial SPV modules - 5600-5700 Wp.
W.R.I D.D. Schedule of Rates 2021,ch. 12, item no. 1) C) BRAND-HAVELS/ PHILIPS
6
11544
69269.82
... More
Power conditioning unit with IP54 enclosure:
Supply, transport, installation and commissioning of IP 54 protected enclosured Inverter Unit qualifying IEC 61683-Efficiency measurement and IEC 60068-2-Environment Standard safety standard suitable for 3 Phase A.C. motor, IGBT based high voltage switching inverter with MPPT technology, to take care of the variation of Sun light and will be suitably mounted inside the metal enclosure. Inverter should have protection against Dry run, Over current, Under current, Over voltage, Under voltage, Short circuit etc. System should be able to run at low sunshine and minimum 7 to 8 hours a day run should be possible during normal sunshine. condition. Inverter should have option to auto start for any short trip off due to low light/ cloudy situation except for dry run. Inverter should be provided with a display to show the various parameter by the user such as Voltage, Current, Solar panel DC voltage, Inverter IGBT temperature, Out put AC voltage, Output frequency, Pump flow (direct or calculated method), Irradiation etc. The system should store the data at a set interval, be capable to transfer it to external storage device and support communication of its operational parameters and logs over Modbus protocol It should also monitor and save total run time, total water pumped etc. There should be provision for interfacing GPRSbased data transmission.
b) For 1 HP capacity Pump-motor set (As per direction of EIC)
W.R.I D.D. Schedule of Rates 2021,ch. 12, item no.3
1
38253
38253.2
... More
Cable and Accessories: Supplying, fitting and fixings of UV rated Copper Cable laid inside HOPEconduit and other accessories as per followings with necessary connection with the Solar PV Module, MPPT etc. i. 4.0 Sq mm single core multi studs - 5 Mtrs (Minimum) ii. Lugs, HDPE Pipe, Flexible Pipe, Saddle, Cable tie etc
W.R.I D.D. Schedule of Rates 2021,ch. 12, item no. 4
1
1351
1351.5
... More
Earthing: earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 mts long and x 4 SWG GI wire ( 4 mtrs long ) 13 mm x 80 mm long GI bolts, double nuts, double nuts…… washers etc.
1
3171
3171.38
... More
Supplying, Fitting Fixing & Installation of Iran Removing Filter Plant Capacity 1500LPH IR Media Filter Working Downilow Max Flow Rate-3m3/hr Working Pressure-1-3 kg/cm2 Size-14"X65 Make Pentair (BIS Standards & Including 1 Year Warranty)
2
19695
39390
... More
Supply and fixing MC4 connector for panel loop.
6
71
429.06
... More
Connecting the all equipment to earth busbar Including GI (Hot Dip) wire of size as below on wall floor as required and making connecion to equipment with bolts, nuts, washers cable lugs as required and mending good damages No. 4 SWG.
20
21
429
... More
Supply, installation testing & lowering of 2 HP oil filled Solar submersible pump motor set complete having Suitable discharge as per yield test of well. Submersible cable of 30 mtr 3 core 25 sqm cable with MOC bar chart and necessary control panel and starter asper manufacturer specification.(Prakash Gold Proxys Solar/ Shreejee/Waaree)
1
35560
35560.63