Haridwar Roorkee Development Authority Tender

View complete overview of Uttarakhand HRDA Tender

Haridwar Roorkee Development Authority - HRDA Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date3 Jul 2024
Closing Date24 Jul 2024
Tender Amount₹ 1,32,11,64,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.

15442.46

-

-

... More
Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. All kinds of soil

31515.99

-

-

... More
Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor:

6811.65

-

-

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)

81.54

-

-

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering -1:3:6 (1 Cement : 3 coarse sand (zone-III): 6 graded stone aggregate 40 mm nominal size).

23.6

-

-

... More
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size)

1049.73

-

-

... More
Providing and laying damp-proof course 40 mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5 mm nominal size).

95.05

-

-

... More
Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth.

185.19

-

-

... More
Centering and shuttering including strutting, propping etc. and removal ofform for : Foundations, footings, bases of columns, etc. for mass concrete

766.99

-

-

... More
Centering and shuttering including strutting, propping etc. and removal ofform for : Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.

5317.82

-

-

... More
Centering and shuttering including strutting, propping etc. and removal ofform for : Suspended floors, roofs, landings, balconies and access platform

19445.67

-

-

... More
Centering and shuttering including strutting, propping etc. and removal ofform for : Lintels, beams, plinth beams, girders, bressumers and cantilevers

15038.73

-

-

... More
Centering and shuttering including strutting, propping etc. and removal ofform for : Columns, Pillars, Piers, Abutments, Posts and Struts

7064.21

-

-

... More
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars

2384641

-

-

... More
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge.“(Note :- Cement content considered in this item is @ 330 kg/cum.“Excess/ less cement used as per design mix is payable/recoverable separately).All works upto plinth level

8490.33

-

-

... More
Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge.“(Note :- Cement content considered in this item is @ 330 kg/cum.“Excess/ less cement used as per design mix is payable/recoverable separately). All works above plinth level upto floor V level

7138.32

-

-

... More
Providing and fixing of expansion joint system related with floor location as per drawings and direction of Engineer-In-Charge. The joints system will be of extruded aluminum base members, self aligning / self centering arrangement and support plates etc. as per ASTM B221-02. The system shall be such that it provides floor to floor /floor to wall expansion control system for various vertical localtion in load application areas that accommodates multi directional seismic movement without stress to it's components. System shall consist of metal profiles with a universal aluminum base member designed to accommodate various project conditions and finish floor treatments. The cover plate shall be designed of width and thickness required to satisfy projects movement and loading requirements and secured to base members by utilizing manufacturer’s pre-engineered self- centering arrangement that freely rotates / moves in all directions. The Self - centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. Provision of Moisture Barrier Membrane in the Joint System to have watertight joint is mandatory requirement all as per the manufactures design and as approved by Engineer -in- Charge. (Material shall confirm to ASTM 6063). Floor Joint of 100 mm gap

576

-

-

... More
Providing and fixing of expansion joint system related with wall joint (internal/ external) location as per drawings and direction of Engineer-In- Charge. The joints shall be of extruded aluminum base members, self aligning / centering arrangement and support plates as per ASTM B221- 02. The material shall be such that it provides an Expansion Joints System suitable for vertical wall to wall/ wall to corner application, both new and existing construction in office Buildings & complexes with no slipping down tendency amongst the components of the Joint System. The Joint System shall utilize light weight aluminum profiles exhibiting minimal exposed aluminum surfaces mechanically snap locking the multicellular to facilitate movement. (Material shall confirm to ASTM 6063). Wall Joint of 100 mm gap

224

-

-

... More
Providing and fixing of expansion joint system of approved make and manufactures for various roof locations as per approved drawings and direction of Engineer-In-Charge. The joints shall be of extruded aluminum base members with, self aligning and self centering arragement support plates asper ASTM B221-02. The system shall be such that it provides watertight roof to roof/roof to corner joint cover expansion control system that is capable of accommodating multidirectional seismic movement without stress to its components. System shall consist of metal profile that incorporates a universal aluminum base member designed to accommodate various project conditions and roof treatments. The cover plate shall be designed of width and thickness required to satisfymovement and loading requirements and secured to base members by utilizing manufacturer’s pre-engineered self-centering arrangement that freely rotates / moves in all directions. The Self centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. The Joint System shall resists damage or deterioration from the impact of falling ice, exposure to UV, airborne contaminants and occasional foot traffic from maintenance personnel. Provision of Moisture Barrier Membrane in the Joint System to have water tight joint is mandatory requirement. (Material shall confirm to ASTM 6063.)

70

-

-

... More
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand)

9.19

-

-

... More
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand)

188.76

-

-

... More
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand)

75.89

-

-

... More
Extra for brick work / AAC block masonry / Tile brick masonry in superstructure above floor V level, for each four floors or part thereof by mechanical means.

95.46

-

-

... More
Extra for forming cavity 5 cm to 11.5 cm wide in cavity walls with necessary weep and vent holes including use of cores and cost of providing and fixing bitumastic coated M .S. ties 300 mm long of 25x3 mm section at not less than 3 ties per sqm as per approved design.

5427.33

-

-

... More
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level Cement mortar 1:4 (1 cement :4 coarse sand)

61.4

-

-

... More
Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry.

61.4

-

-

... More
Providing and laying Autoclaved Aerated concrete(AAC) blocks masonry 100 mm/ 125 mm thick with Grade-1 AAC blocks of density 551 to 650 kg/cum conforming to IS:2185 (Part 3) in super structure above plinth level up to floor V level in cement mortar 1:4 (1 cement : 4 coarse sand ). The rate includes providing and placing in position 2 Nos 6 mm dia M.S. bars at every third course of masonry work.

1107.68

-

-

... More
Providing and laying Autoclaved Aerated concrete(AAC) blocks masonry with 150 mm to 300 mm thick with Grade-1 AAC blocks of density 551 to 650 kg/cum conforming to IS:2185 (Part 3) in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately).

1801.83

-

-

... More
Stone work, plain in copings, cornices, string courses and plinth courses, upto 75 mm thick in Cement mortar 1:6 (1 cement : 6 coarse sand), including pointing with white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade.White sand stone.

4.7

-

-

... More
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Granite of any colour and shade Area of slab upto 0.50 sqm

136.24

-

-

... More
Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge.Granite work

227.07

-

-

... More
Extra for fixing marble /granite stone, over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive, including cleaning etc. complete

227.07

-

-

... More
Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete.

80

-

-

... More
Stone tile (polished) work for wall lining over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and cement slurry @ 3.3 kg/sqm including pointing in white cement complete. 8mm thick Granite of any colour and shade

2031.18

-

-

... More
Providing and fixing machine cut, mirror/ eggshell polished , Marble stone work for wall lining (veneer work) including dado, skirting, risers of steps etc., in required design and pattern wherever required, stones of different finished surface texture, on 12 mm (average) thick cement mortar 1:3 (1 cement : 3 coarse sand) laid and jointed with white cement slurry @ 3.3 kg/sqm including pointing with white cement slurry admixed with pigment of matching shade, including rubbing, curing, polishing etc. all complete as per Architectural drawings, and as directed by the Engineer-in-Charge. 18 mm thick Italian Marble stone slab,Perlato, Rosso verona, Fire Red or Dark Emperadore etc.

1949.42

-

-

... More
Providing and fixing dry cladding upto 10 metre height with 30 mm thick gang saw cut stone with machine cut edges of uniform colour and size upto 1mx1m, fixed to structural steel frame work and/ or with the help of cramps, pins etc. and sealing the joints with approved weather sealant as per Architectural drawing and direction of Engineer-in-charge. (The steel frame work, stainless steel cramps and pins etc. shall be paid for separately).White sand stone - 30 mm thick gang saw cut stone

5538.88

-

-

... More
Providing and fixing structural steel frame (for dry cladding with 30 mm thick gang saw cut with machine cut edges sand stone) on walls at all heights using M.S. square/ rectangular tube in the required pattern as per architectural drawing, including cost of cutting, bending, welding etc. The frame work shall be fixed to the wall with the help of M.S. brackets/ lugs of angle iron/ flats etc. which shall be welded to the frame and embedded in brick wall with cement concrete block 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20 mm nominal size) of size 300x230x300 mm, including cost of necessary centring and shuttering and with approved expansion hold fasteners on CC/RCC surface, including drilling necessary holes. Approved cramps/ pins etc. shall be welded to the frame work to support stone cladding, the steel work will be given a priming coat of Zinc primer as approved by Engineer-in-charge and painted with two or more coats of epoxy paint (Shop drawings shall be submitted by the contractor to the Engineer-in-charge for approval before execution). The frame work shall be fixed in true horizontal & vertical lines/planes. (Only structural steel frame work shall be measured for the purpose of payment, stainless steel cramps shall be paid for separately and nothing extra shall be paid).

55388.75

-

-

... More
Providing and fixing in wall lining flat pressed three layer (medium density) particle board or graded wood Pre-laminated one side decorative lamination and other side balancing lamination Grade |, Type Il, IS : 12823 marked, including priming coat on unexposed arrangement and screws etc. complete : 18 mm thick

537.27

-

-

... More
Providing and fixing specified wood frame work consisting of battens 50x25 mm fixed with rawl plug and drilling necessary holes for rawl plug etc. including priming coat complete. Kiln seasoned and chemically treated hollock wood

2.24

-

-

... More
Providing and fixing plywood 4 mm thick, one side decorative veneer conforming to IS: 1328 (type-1), for plain lining / cladding with necessary screws, including priming coat on unexposed surface with : Decorative veneer facings of approved manufacture

537.27

-

-

... More
Designing, fabricating, testing, installing and fixing in position Curtain Wall with Aluminium Composite Panel Cladding, with open grooves for linear as well as curvilinear portions of the building , for all heights and all levels etc. including: (a) Structural analysis & design and preparation of shop drawings for pressure equalisation or rain screen principle as required, proper drainage of water to make it watertight including checking of all the structural and functional design. (b) Providing, fabricating and supplying and fixing panels of aluminium composite panel cladding in pan shape in metalic colour of approved shades made out of 4mm thick aluminium composite panel material consisting of 3mm thick FR grade mineral core sandwiched between two Aluminium sheets (each 0.5mm thick). The aluminium composite panel cladding sheet shall be coil coated, with Kynar 500 based PVDF / Lumiflon based fluoropolymer resin coating of approved colour and shade on face # 1 and polymer (Service) coating on face # 2 as "specified using stainless steel screws, nuts, bolts, washers, cleats, weather silicone sealant, backer rods etc. (c) The fastening brackets of Aluminium alloy 6005 T5 / MS with Hot Dip Galvanised with serrations and serrated washers to arrest the wind load movement, fasteners, SS 316 Pins and anchor bolts of approved make in SS 316, Nylon separators to prevent bi-metallic contacts all complete required to perform as per specification and drawing The item includes cost of all material & labour component, the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working curtain wall" with aluminium composite panel cladding, cleaning and protection of the curtain wall with aluminium composite panel cladding till the handing over of the building for occupation. Base frame work for ACP cladding is payable under the relevant aluminium item.s The Contractor shall provide curtain wall with aluminium composite panel cladding, having all the performance characteristics all complete , as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer-in-Charge. However, for the purpose of payment, only the actual area on the external face of the curtain wall with Aluminum Composite Panel Cladding (including width of groove) shall be measured in sqm. up to two decimal places.

556

-

-

... More
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws

284.94

-

-

... More
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.

16199.68

-

-

... More
Providing and fixing ISI marked oxidised M.S.sliding door bolts with nuts and screws etc 300x16 mm

188

-

-

... More
250x16 mm

188

-

-

... More
Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. 125 MM

212

-

-

... More
Providing and fixing oxidised M.S. casement stays (straight peg type) with necessary screws etc.

188

-

-

... More
Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyedto required colour or shade, with necessary screws etc. complete :250x10 mm

424

-

-

... More
Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyedto required colour or shade, with necessary screws etc. complete : 150X10 MM

424

-

-

... More
Providing and fixing bright finished brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.

188

-

-

... More
Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete.

188

-

-

... More
Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : 300x16 mm

3

-

-

... More
Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : 250x16 mm

3

-

-

... More
Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyedto required colour or shade, with necessary screws etc. complete : 250x10 mm

3

-

-

... More
Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyedto required colour or shade, with necessary screws etc. complete : 150X10 MM

3

-

-

... More
Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete :

6

-

-

... More
Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. Single rubber stopper

195

-

-

... More
Providing and fixing fire resistant door frame of section 50 x 60 mm on horizontal side & 35 x 60 mm on vertical sides having built in rebate made out of 1.6 mm thick GI sheet (Zinc coating not less than 120 gm/sqm) suitable for mounting 120 minutes Fire Rated Glazed Door Shutters. The frame shall be filled with mineral wool Insulation having density minimum 96Kg/sqm. The frame will have a provision of G.I. anchor fastners 14 nos (5 each on vertical style & 4 on horizontal style of size M10 x 80) suitable for fixing in the opening along with factory made template for SS ball bearinghinges of size 100x89x3 mm for fixing of fire rated glazed shutter. The frame shall be finished with an approved fire resistant primer or powder coating of not less than 30 micron in desired shade as per the directions of Engineer - in- Charge. (Cost of SS ball bearing hinges is excluded).

72

-

-

... More
Providing and fixing 60 mm thick glazed fire resistant door shutters of 120 minutes Fire rating conforming to 1S:3614 (Part Il) or EN1634-1:1999, tested and certified as per laboratory approved by Engineer-in-Charge, with suitable mounting on door frame, consisting of vertical styles, top rail & side rail 60 mm x 60 mm wide and bottom rail of 110 mm x 60 mm made out of 1.6 mm thick G.I. sheet (zinc coating not less than 120 gm/ sqm) duly filled mineral wool insulation having density minimum 96 kg/ cum and fixing with necessary stainless steel ball bearing hinges of size 100x89x3 mm of approved make, including applying a coat of approved fire resistant primer or powder coating not less than 30 micron etc all complete as per direction of Engineer-in-Charge (panelling to be paid for seperately).

40.32

-

-

... More
Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete.125 mm

16

-

-

... More
Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)

311.04

-

-

... More
Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)

3460.35

-

-

... More
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets,

51857.16

-

-

... More
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless\ steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).

216

-

-

... More
Providing & fixing fly proof wire gauze to windows, clerestory windows & doors with M.S. Flat 15x3 mm and nuts & bolts complete. Galvanised M.S. Wire gauze with 0.63 mm dia wire and 1.4 mm aperture on both sides

17.28

-

-

... More
Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes

4.32

-

-

... More
Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 5.5 mm thick glass panes

12.96

-

-

... More
Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick

94.41

-

-

... More
Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.

583.45

-

-

... More
40 mm thick rubbed stone flooring over 20 mm (average) thick base of cement mortar 1:5 (1 cement : 5 coarse sand) with joints 3 mm thick, side buttered with cement mortar 1:2 (1 cement : 2 stone dust) admixed with pigment to match the shade of stone and pointing with same mortar. Red sand stone

315.4

-

-

... More
25 mm wooden planking, tongued and grooved in flooring, including fixing with iron screws complete with : Second class teak wood

534.29

-

-

... More
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mm

3225.48

-

-

... More
Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge.Size of Tile 600x600 mm

3125.48

-

-

... More
Providing and laying machine cut, mirror polished Marble stone flooring, in required design (Simple geometrical, abstract etc.) and in patterns in combination with Italian marble stones of different colours, shades and finished surface texture etc., in linear portions of the building, all complete as per the architectural drawings, with 18 mm thick stone slab laid over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with white cement slurry @ 4.4 kg/sqm, including pointing with white cement slurry admixed with pigment to match the marble shade, including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. 18 mm thick Italian Marble stone slab, Perlato, Rosso verona, Fire Red or Dark Emperadore etc.

2569.01

-

-

... More
Providing and fixing Glass mossaic tiles on finished plain wall surface of size 20 mm x 20 mm x 4 mm in all colour, design , fixing in customize design as per direction of Engineer-in- Charge. The glass mosaic tiles to be fixed on the wall surface with the help of approved adhesive applied at the rate of 2.5 kg per sqm and grouting of the same. The rate is inclusive of all operation, material and required pattern approved by Engineer-in- Charge:

134.46

-

-

... More
Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.

804.96

-

-

... More
Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.

806.02

-

-

... More
Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10mm and down gauge) including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : In 75x75mm deep chase

225

-

-

... More
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1mx1mx400micron, finished with 12mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement rounding the edge sand making and finishing the outlet complete.

79

-

-

... More
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS :110 mm diameter

1675.95

-

-

... More
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. Coupler(110 mm)

158

-

-

... More
Bend 87.5 degree 110 mm bend

79

-

-

... More
Shoe (Plain) 110 mm Shoe

79

-

-

... More
Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50mm hard wood plugs,screwed with M.S. screws of required length including

310

-

-

... More
Providing and fixing false ceiling at all heights including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm cic, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer’s specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : Providing and fixing false ceiling at all heights including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm cic, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer’s specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : Fully Perforated Gypsum Plaster Board of size 1200 x 2400x12.5 mm having approx. 15 % perforated area with perforation size and pattern as approved by the Engineerin- charge and as per manufacturer’s specification, with all 4 sides tapered and backed by acoustical tissue with NRC value not less than 0.60

2569.01

-

-

... More
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineerin- charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.

37.8

-

-

... More
Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main “T” runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross “T” of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main “T” at 600 mm center to center to form a grid of 1200x600 mm and secondary cross “T” of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved\ texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main “T” runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge.12.5 mm thick square edge PVC Laminated Gypsum Tile of size 595x595 mm, made of Gypsum plasterboard, manufactured from natural gypsum as per IS 2095 part | and laminated with white 0.16 mm thick fire retardant PVC film on the face side and 12 micron metalized polyester on the back side with all edges sealed with the face side PVC film which goes around and wraps the edges and is bonded to the edges and the back side metalized polyester film so as to make the tile a completely sealed unit.

2609.75

-

-

... More
Providing and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) 78, solar reflection 0.70 and initial emittance 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet walls in the same manner.

430.62

-

-

... More
Providing and laying roof insulation with 40 mm thick impervious sprayed, closed cell free Rigid Polyurethane foam over deck insulation conforming to IS - 12432 Pt. Ill (density of foam being 40-45 kg/ cum), over a coat of polyurethane primer applied @ 6-8 sqm per litre, laying 400 G polythene sheet over PUF spray and providing a wearing course of 40 mm thick cement screed 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 20 mm nominal size) in chequered rough finish, in panels of 2.5 m x 2.5 m and embedding with 24 G wire netting and sealing the joints with polymerized mastic, all complete as per direction of Engineer-in-Charge.

2777.44

-

-

... More
Providing and fixing thermal insulation with Resin Bonded Fibre glass wool conforming to IS: 8183 having density 24 kg/m3, 50 mm thick, wrapped in 200G Virgin Polythene Bags fixed to wall with screw, rawel plug & washers and held in position by criss crossing GI wire etc. complete as per directions of Engineer-in-Charge.

7876.12

-

-

... More
12 mm cement plaster of mix :1:6 (1 cement: 6 fine sand)

24580.72

-

-

... More
15 mm cement plaster on the rough side of single or half brick wall of mix : 1:6 (1 cement: 6 fine sand)

6720.76

-

-

... More
12 mm cement plaster finished with a floating coat of neat cement :1:4 (1 cement : 4 fine sand)

80.74

-

-

... More
15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix : 1:3 (1 cement: 3 fine sand)

1072.5

-

-

... More
15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand)

115.01

-

-

... More
6 mm cement plaster of mix : 1:3 (1 cement : 3 fine sand)

43.55

-

-

... More
Extra for plastering done on moulding, cornices or architraves including neat finish to line and level: In one coat

1186.7

-

-

... More
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.

103.85

-

-

... More
Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer’s specification. Two or more coats on new wor

43568.43

-

-

... More
Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm

5299.76

-

-

... More
Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)

1277

-

-

... More
Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/ 10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand and manufacture

943.68

-

-

... More
Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/10 sqm of approved brand and manufacture

1912.4

-

-

... More
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture

543.32

-

-

... More
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete..

44651.28

-

-

... More
Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earthwith lead upto 50 metres.

3327.83

-

-

... More
Extra for compaction of earth work in embankment under optimum moisture conditions to give at least 95% of the maximum dry density (proctor density).

2228.43

-

-

... More
Providing & laying vacuum dewatered flooring (Tremix Floor) of RCC M-25 including providing side shuttering with MS channels, vibrating concrete by using screed vibrator and suction dewatering using approved make equipment and finishing the top surface to required level and grade using power trowels of standard make. Rate to include for covering the finished concrete surface (Reinforcement shall be measured and paid separetely.)

1104.4

-

-

... More
Extra for providing and mixing hardening compound of approved quality as per manufacturer’s specification in cement concrete.

3313.19

-

-

... More
Providing and fixing in position pre-moulded joint filler in expansion per cm depth joints.

198

-

-

... More
Providing and laying in position bitumen hot sealing compound for expansion joints etc. Using grade ‘A’ sealing compound.

198

-

-

... More
Manufacturing, supplying and fixing retro reflective sign boards made up of 2 mm thick aluminium sheet, face to be fully covered with high intensity encapsulated type heat activated retro reflective sheeting conforming to type - IV of ASTM-D 4956-01 in blue and silver white or other colour combination including subject matter, message (bilingual), symbols and borders etc. as per IRC ; 67:2001, pasted on substrate by an adhesive backing which shall be activated by applying heat and pressure conforming to class -2 of ASTM-D-4956-01 and fixing the same with suitable sized aluminium alloy rivets @ 20 cm c/c to back support frame of M.S. angle iron of size 25x25x3 mm along with theft resistant measures, mounted and fixed with 2 Nos. M.S. angles of size "35x35x5 mm to a vertical post made up to M.S. Tee section ISMT 50x50x6 mm welded with base plate of size 100x100x5 mm at the bottom end and including making holes in pipes, angles flats, providing & fixing M.S. message plate of required size, steel work to be painted with two or more coats of synthetic enamel paint of required shade and of approved brand & manufacture over priming coat of zinc chromate yellow primer (vertical MS-Tee support to be painted in black and white colours).Backside of aluminium sheet to be painted with two or more coats of epoxy paint over and including appropriate priming coat including all leads and lifts etc. complete as per drawing , specification and direction of Engineer-in-charge." Mandatory/ Regulatory sign boards of 900 mm diametre with support length of 3750 mm

10

-

-

... More
Cautionary /warning sign boards of equilateral triangular shape having each side of 900 mm with support length of 3650 mm

5

-

-

... More
Providing and laying 60 mm thick faciory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge.

256.57

-

-

... More
Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge).

148.5

-

-

... More
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work 20 mm dia nominal bore

20

-

-

... More
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. 80 mm dia nominal bore

80

-

-

... More
Providing and fixing gun metal non- return valve of approved quality (screwed end) :80 mm nominal bore Horizontal

5

-

-

... More
Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S.(non modular) bricks of class designation 7.5

2

-

-

... More
Constructing masonry Chamber 120x120x100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S.(non modular) bricks of class designation 7.5

2

-

-

... More
Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete :250 mm dia. R.C.C. pipe

360

-

-

... More
Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as per standard design : With 20x20 mm square bar

40

-

-

... More
Replacement of M.S. foot rests in manholes including dismantling concrete blocks and fixing with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size): With 20x20 mm square bar

9

-

-

... More
Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality L D- 2. Rectangular shape 600x450 mm internal dimensions

6

-

-

... More
Providing and laying Non Pressure NP-3 class (Medium duty) R.C.C. pipes including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete 600 mm dia RCC pipes.

50

-

-

... More
Constructing brick masonry road gully chamber 50x45x60 cm with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm pre-cast R.C.C. horizontal grating with frame complete as per standard design : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5

36

-

-

... More
Providing and laying Non Pressure NP-4 class (Heavy duty) R.C.C. pipes including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete 1800 mm dia RCC pipes. (Laying by manual/ machanical means)

5.5

-

-

... More
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For fixed portionPolyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron)

4050

-

-

... More
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm).

182.5

-

-

... More
Providing and fixing double glazed hermetically sealed glazing in aluminium windows, ventilators and partition etc. with 6 mm thick clear float glass both side, having 12 mm air gap, including providing EPDM gasket, perforated aluminium spacers, desiccants, sealant (Both primary and secondary sealant) etc. as per specifications, drawings and direction of Engineer-in-charge complete.

1661.42

-

-

... More
Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge (Door handle, lock and stopper etc.to be paid separately).

926.33

-

-

... More
Providing and laying integral cement based treatment for water proofing on horizontal surface at all depth below ground level for under ground structures as directed by Engineer-in-Charge and consisting of : (i) Ist layer of 22 mm to 25 mm thick approved and specified rough stone slab over a 25 mm thick base of cement mortar 1:3 (1 cement : 3 coarse sand) including applying of twice ( at base and top of mortar ) cement slurry @ 2.2kg/m2 (each time) mixed with water proofing compound conforming to IS:2645 in the recommended proportion over the leveling course (leveling course to be paid separately). Joints sealed and grouted with cement slurry mixed with water proofing compound.(ii) 2nd layer of 25 mm thick cement mortar 1:3 (1 cement: 3 coarse sand) mixed with water proofing compound in recommended proportions. (iii) Finishing top with stone aggregate of 10 mm to 12 mm nominal size spreading @ 8 cudm/sqm thoroughly embedded in the 2nd layer. Using rough kota stone.

4052.39

-

-

... More
Providing and laying integral cement based treatment for water proofing on the vertical surface by fixing specified stone slab 22 mm to 25 mm thick with cement slurry mixed with water proofing compound conforming to IS:2645 in recommended proportions with a gap of 20 mm (minimum) between stone slabs and the receiving surfaces and filling the gaps with neat cement slurry mixed with water proofing compound and finishing the exterior of stone slab with cement mortar 1:3 (1 cement : 3 coarse sand) 20 mm thick with neat cement punning mixed with water proofing compound in recommended proportion complete at all levels and as directed by Engineer-in-charge : Using rough Kota stone

3005.34

-

-

... More
Providing and laying integral cement based treatment for water proofing on the vertical surface by fixing specified stone slab 22 mm to 25 mm thick with cement slurry mixed with water proofing compound conforming to IS:2645 in recommended proportions with a gap of 20 mm (minimum) between stone slabs and the receiving surfaces and filling the gaps with neat cement slurry mixed with water proofing compound and finishing the exterior of stone slab with cement mortar 1:3 (1 cement : 3 coarse sand) 20 mm thick with neat cement punning mixed with water proofing compound in recommended proportion complete at all levels and as directed by Engineer-in-charge : Using rough Kota stone

192.5

-

-

... More
Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of: (i) Ist course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming to IS : 2645 in recommended proportions including rounding off junction of vertical and horizontal surface. (ii) IInd course of 20 mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. (iii) IIIrd course of applying blown or residual bitumen applied hot at 1. kg. per sqm of area. (iv) IVth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/sqm).

762.19

-

-

... More
Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying :(a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.

134.46

-

-

... More
Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. “All above operations to be done in order and as directed and specified by the Engineer-in-Charge”: With average thickness of 120 mm and minimum thickness at khurra as 65 mm

2777.44

-

-

... More
Grading roof for water proofing treatment with Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size)

1.69

-

-

... More
Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 90 metre depth below ground level. All types of soil All types of soil 300 mm dia

100

-

-

... More
Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.

4.04

-

-

... More
Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge

2.54

-

-

... More
Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -incharge.

2.54

-

-

... More
Providing and fixing factory made precast RCC perforated drain covers, having concrete of strength not less than M-25, of size 1000 x 450x50 mm, reinforced with 8 mm dia four nos longitudinal & 9 nos cross sectional T.M.T. hoop bars, including providing 50 mm dia perforations @ 100 to 125 mm c/c, including providing edge binding with M.S. flats of size 50 mm x 1.6 mm complete, all as per direction of Engineerin- charge.

368

-

-

... More
Supplying, assembling, lowering and fixing in vertical position in bore well, ERW (Electric Resistance Welded) FE 410 plain slotted (having slot of size 1.6/3.2 mm) mild steel threaded and socketed/ plain bevel ended pipe (type A) of required dia, conforming to IS: 8110, of reputed and approved make, having wall thickness not less than 5.40 mm, including painted with outside surface with two coats of anticorrosive bitumestic paint of approved brand and manufacture, including hire & labour charges, fittings & accessories, all complete, for all depths, as per direction of Engineer -in-charge.. 200 mm nominal size dia

100

-

-

... More
Providing and supplying Spandrel Glass Panels comprising of 6 mm thick heat strengthened monolithic float glass of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade so as to match the colour and shade of the IGUs in the vision panels etc. ,all complete for the required performances as specified, as per the Architectural drawings, as per the approved shop drawings, as specified, and as directed by the Engineer- in Charge. For payment, only the actual area of glass on face # 1 of the glass panels (but excluding the area of grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm. (Payment for fixing of Spandrel Glass Panels in the curtain glazing is included in cost of relevent Item*).“(i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face # 2, having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/m2 K etc. . The properties of performance glass shall be decided by technical sanctioning authority as per the site equirement.

786.6

-

-

... More
Design supply & installation of suspended Spider Glazing system designed to withstand the wind pressure as per IS 875 (Part-III). The Suspended System held with Spider Fittings of SS-316 Grade Steel of approved manufacturer with glass panel having 12 mm thick clear toughened glass held together with SS- 316 Grade Stainless steel Spider & bolt assembly with laminated glass fins 21 mm thick. The Glass finsand glass panel assembly shall be connected to Slab/beams by means of SS- 316 Grade stainless steel brackets & Anchor bolts and at the bottom using SS channel of 50x25x2 mm using fastener & anchor bolts, non staining weather sealants of approved make, Teflon/ nylon bushes and separators to prevent bi-metallic contacts, all complete to perform as per specification and approved drawings. The complete system to be designed to accommodate thermal expansion & seismic movements etc. The joints between glass panels (6 to 8 mm) and gaps at the perimeter & in U channel of the assembly to be filled with non staining weather sealant, so as to make the entire system fully water proof & dust proof. The rate shall include all design, Engineering and shop drawing including approval from structural designer, labour, T&P, scaffolding, other incidental charges including wastage, enabling temporary services all fitting fixers nut bolts, washer, Buffer plates, fastener, anchors, SS channel laminated glass etc. all complete. For the purpose of payment, actual elevation area of Glazing including thickness of joints and the portion of Glass panel inside the SS channel shall be measured.

1311.42

-

-

... More
Supplying of standard quality GFRG panel of 124 mm thickness with modular cavities purchased from GFRG panel manufacturing plant in the country, cut to required wall sizes and floor/ roof slab sizes in correct length and height, including cutting of door, window and ventilator opening as per the cutting drawing prepared by architects /design engineers for the construction of GFRG building and loaded in stillages for transportation to the construction site. Cost of panel includes security deposits, hire charges of stillages & jaws, cost of transportation in trucks/ lorries without any damages upto 300kms including all leads and lifts from GFRG manufacturing plant to construction site and unloading at site using suitable fork lift/ crane. (Payment shall be made on the basis of area of one side of panel without reduction of opening of door/ window / ventilator). For transportation above 300kms, additional charges to be paid.

560

-

-

... More
Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for separately). Note: For WPC solid door/window frames, minus 5 mm tolerance in dimensions i.e depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made.Frame size 45 x 85 mm

351.45

-

-

... More
Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately) 30 mm thick

111.83

-

-

... More
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.

1622.16

-

-

... More
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars

15979.54

-

-

... More
Providing and laying design mix cement concrete of M-30 grade, in roads/ taxi tracks/ runways, using cement content as per design mix, using coarse sand and graded stone aggregate of 40 mm nominal size in appropriate proportions as per approved & specified design criteria, providing dowel bars with sleeve/ tie bars wherever required, laying at site, spreading and compacting mechanically by using needle and surface vibrators, levelling to required slope/ camber, finishing with required texture, including steel form work with sturdy M.S. channel sections, curing, making provision for contraction/ expansion, construction & longitudinal joints (10 mm wide x 50 mm deep) by groove cutting machine, providing and filling joints with approved joint filler and sealants, complete all as per direction of Engineer-in-charge (Item of joint fillers, sealants, dowel bars with sleeve/ tie bars to be paid separately). Note:- Cement content considered in M-30 is @ 340 kg/cum. Excess/ less cement used as per design mix is payable/ recoverable separately. Cement concrete prepared with batch mixing machine

407.12

-

-

... More
Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. With material conforming to Grade-I (size range 75 mm to 0.075 mm) having CBR Value-30

64.8

-

-

... More
Providing and applying 2.5 mm thick road marking strips (retroreflective) of specified shade/ colour using hot thermoplastic material by fully/ semi automatic thermoplastic paint applicator machine fitted with profile shoe, glass beads dispenser, propane tank heater and profile shoe heater, driven by experienced operator on road surface including cost of material, labour, T&P, cleaning the road surface of all dirt, seals, oil, grease and foreign material etc. complete as per direction of Engineer-in- charge and accordance with applicable specifications.

148.5

-

-

... More
Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. With material conforming to Grade-I (size range 75 mm to 0.075 mm) having CBR Value-30

695.21

-

-

... More
Providing, laying, spreading and compacting graded stone aggregate (size range 53 mm to 0.075 mm ) to wet mix macadam (WMM) specification including premixing the material with water at OMC in for all leads & lifts, laying in uniform layers with mechanical paverfinisher in sub- base / base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achievethe desired density, complete as per specifications and directions of Engineer-in-Charge.

579.34

-

-

... More
Grassing with selection No. 1/ Doob grass including watering and maintenance of the lawn for 30 days or more till the grass forms a thick lawn, free from weeds and fit for mowing including supplying good earth, if needed (the grass and good earth shall be paid for separately). With grass Turf

2049

-

-

... More
Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after eduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately) Holes 1.2 m dia and 1.2 m deep

10

-

-

... More
Holes 90 cm dia, and 90 cm deep

5

-

-

... More
Holes 60 cm dia, and 60 cm deep

20

-

-

... More
Holes 45 cm dia, and 45 cm deep.

30

-

-

... More
Filling mixture of earth and sludge or manure in the desired proportion in trenches, flooding with water and leveling (cost of supplying earth and sludge or manure and mixing excluded).

614.7

-

-

... More
Preparation of mounds of various size and shape by available excavated / supplied earth in layers not exceeding 20 cm in depth, breaking clods, watering of each layer, dressing etc., lead upto 50 meter and lift upto 1.5 m complete as per direction of Officer-in-charge.

614.7

-

-

... More
Supplying and stacking sludge at site including royalty and carriage upto 5 km lead complete (sludge measured in stacks will be reduced by 8% for payment).

307.35

-

-

... More
Spreading of sludge, dump manure and/or good earth in required thickness as per direction of officer-in-charge (cost of sludge, dump manure and/ or good earth to be paid separately).

614.7

-

-

... More
Mixing earth and sludge or manure in the required proportion specified or directed by the Officer-in- charge

614.7

-

-

... More
Anti termite treatment of lawn area through premise 30.50% I P. one liter premise diluted in 499 liters water and applying solution @ 1.00 litre solution per sqm lawn or bed area.(two application)i/c cost of chemical)

2049

-

-

... More
Providing stacking and installation of Butea frondosa (Flame of Forest) plant of height 60-75 cm. in big poly bags of size 25 cm.

60

-

-

... More
Providing , stacking and installation of Jacaranda mimosifolia plant of height 150-165 cm. in big poly bags of size 25 cm

45

-

-

... More
Providing, stacking and installation of Cassia fistula (Amaltas) plant of height 120-135 cm. in big poly bags of size 25 cm

60

-

-

... More
Providing and stacking of Peltophorum ferrugineum plant of height 150-165 cm. in big poly bags of size 25 cm

60

-

-

... More
Supply and stacking of Millingtonia hortensis plant of height 150-165 cm. in big poly bag of size 25 cm

40

-

-

... More
Providing and stacking of Chorisia speciosa (Mexican silk cotton) plant of height 150-165 cm. in big poly bags of size 25 cm.

60

-

-

... More
Providing and stacking of Bauhinia blakeana (Hong Kong Orchid Tree) plant of height 120-150 cm. in big poly bags of size 25 cm.

60

-

-

... More
Providing and stacking of Mimusops elengi (Maulsari) plant of height 180-195 cm., well developed with thick stem in big size HDPE bag.

30

-

-

... More
Supply and stacking of Plumeria alba of height 165-180 cm. with 3-4 branches and thick stem in big size HDPE bags

60

-

-

... More
Supply and stacking of Plumeria rubra plant of height 120-150 cm. with 3-4 branches and thick stem in big size HDPE bags

25

-

-

... More
Providing and stacking of Callistemon lanceolatus plant of height 150-165 cm. in big poly bags of size 25 cm

20

-

-

... More
Providing and stacking of Tabebuia argentea of height 150-165 cm. in big poly bags of size 25 cm.

20

-

-

... More
Providing and stacking of Tabebuia avellanedae of height 150-165 cm. in big poly bags of size 25 cm.

15

-

-

... More
Providing and stacking of Tabebuia rosea of height 150-165 cm. in big poly bags of size 25 cm.

15

-

-

... More
Providing and stacking of Lagerstroemia flos reginae plant of height 150-165 cm.in big poly bag of size 25 cm

15

-

-

... More
Providing and stacking of Lagerstroemia thorelli (Arjun) plant of height 150-165 cm.in big poly bag of size 25 cm

15

-

-

... More
Providing and stacking of Lagerstroemia flos reginae plant of height 90-105 cm multibranched in polybags of size 25cm

15

-

-

... More
Providing and stacking of Wodyetia bifurcata (Foxtail palm) of height 240cm-270cm bottle girth 35cm-40cm in big size HDPE bags

25

-

-

... More
Providing and Displaying Bismarckia Palm 115 to 180 cm ht., well developed 12 and above good color fresh and healthy leaves in 40 cm Cement Pot.

25

-

-

... More
Providing and Stacking of Washingtonia filifera palm, stem height 120-135cm with 8-10 healthy leaves lush green leaves, well developed in big size HDPE bags

30

-

-

... More
Providing and Stacking of Oreodoxa (Bottle plam) 270 to 300 cm bottom girth 40-50cm in HDPE bags

25

-

-

... More
Providing and stacking of Phoenix roebelenii palm well developed having 20 to 25 fresh & healthy leaves 90 to 105 cm ht. in 30 cm Cement Pot.

20

-

-

... More
Providing and Displaying Cycas revoluta specimen plant, having 45 to 50 fresh and healthy, leaves having 30cm to 35cm circumfrance of base stem well developed in 40 cm challi

30

-

-

... More
Providing and Displaying Furcraea variegated hybrid well developed with fresh & healthy foliage 20 and above attractive leaves in 35cm Cement Pot

30

-

-

... More
Supply and stacking of plant Caesalpinia pulcherrima (Peacock flower) species of height 45-60 cm. in earthen pot of size 20 cm

30

-

-

... More
Providing and stacking of plant Jatropha multifida (red colour) of height 60-75 cm., multibranched in polybag of size 25 cm

30

-

-

... More
Supply and stacking of plant Tecoma gaudichaudi of height 90-105 cm.,bushy in big size HDPE bags

20

-

-

... More
Providing and stacking of plant Hamelia patens of height 90-105 cm. bushy in big size HDPE bags.

20

-

-

... More
Supply and stacking of Bougainvillea species (Variety Butiana, Lady Mary Baring, Mahara,Mohan,Scarlet Queen, Varigata, Glabra Formosa, Peruviana Odissi, Partha, Subhra,Thimma, Spectabilis L.N Birla, Refulgens) plant of height 30 cm. to 45 cm. with 2-3 branches in 20 cm size of Earthen pots / Plastic pots

30

-

-

... More
Providing and stacking of plant Plumbago capensis well developed with fresh and healthy 30 to 45 cm ht., with bloom in 20 cm Earthen Pot/Plastic Pot.

30

-

-

... More
Providing and stacking of plant Hamelia patens (Dwarf ) of height 30-45 cm. with 3-4 branches in earthen pots of size 20 cm.

30

-

-

... More
Providing and stacking of plant Nerium oleander (kaner) of height 60-75 cm. with 5-6 branches in poly bags of size 25 cm.

30

-

-

... More
Providing and displaying of Brassia hicolour 3 in 1 well developed with fresh, healthy from bottom to top with 30 cm to 45 cm ht. in 25 cm size Plastic pot/Earthen pot.

20

-

-

... More
Providing and stacking of Alpinia Variegated (three in one) having ht. 30 cm and above, with fresh and healthy variegated foliage in 25 cm size of Earthen Pot / Plastic Pot.

20

-

-

... More
Supply and stacking of Schefflera Variegated plant, mounted on moss stick 90 cm ht., 3 to 4 plants placed in each pot at equal distance, well developed with full of fresh & healthy bright leaves from bottom to top in 25 cm size of Earthen pot / Plastic pot

20

-

-

... More
Providing and Displaying of Schefflera green 3 in 1 well developed with fresh, healthy and attractive foliage from having 45 cm to 60 cm ht. in 25 cm size Earthen pot/Plastic pot

20

-

-

... More
Supply and stacking of plant Murraya exotica (Kamini) of height 45-60 cm. in poly bags of size 15 cm

20

-

-

... More
Providing and stacking Canna dwarf of height 25 to 30 cm., 2 to 3 suckers in earthen pots of size 20 cm Earthen Pot/Plastic Pot.

20

-

-

... More
Supply and stacking of plant Gardenia jasminoides of height 45-60 cm. with 3 - 4 branches in earthen pots of size 20 cm

20

-

-

... More
Providing and stacking of Tabernaemontana coronaria (Chandi single) variegated of height 105- 120cm., multibranched, bushy in big size HDPE bag

20

-

-

... More
Supply and stacking of Ficus long island 15cm to 20 cm, full of branches and foliage in 20cm size of earthen pot/plastic pot.

20

-

-

... More
Providing and stacking of Golden Duranta plant, having ht.15 to 20 cm bushty shape plant with fresh and healthy leaves in 20 cm size of Earthen Pot / Plastic Pot

25

-

-

... More
Supply and stacking of Asparagus meyeri, well developed 15cm to 20 cm, full of branches and foliage in 25cm size of earthen pot/plastic pot.

25

-

-

... More
Providing and stacking of Ophiopogon jaburan (variegated) plant, full of variegated leaves in Earthen Pot/Plastic Pot of size 20 cm

10

-

-

... More
Providing and Displaying of Wedelia trilobata plant,full of leaves in 15 cm size of Poly bags.

20

-

-

... More
Providing and Displaying of Iresine herbstii plant, of height 20-30 cm., full of branches well developed in 15 cm size of Earthen Pot / Plastic Pot

15

-

-

... More
Providing & fixing of vertical plantation on walls with natural plants complete in all respects as per direction given by engineer in charge.

300.3

-

-

... More
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. Group C

1450

-

-

... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire

1450

-

-

... More
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire

4500

-

-

... More
2 X 4 sq. mm + 1 X 4 sq. mm earth wire

3500

-

-

... More
2 X 6 sq. mm + 1 X 6 sq. mm earth wire

600

-

-

... More
2 X 10 sq. mm + 1 X 10 sq. mm earth wire

200

-

-

... More
4 X 2.5 sq. mm + 2 X 2.5 sq. mm earth wire

1600

-

-

... More
4 X 4 sq. mm + 2 X 4 sq. mm earth wire

1750

-

-

... More
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 4 way (4 + 12), Double door

27

-

-

... More
8 way (4 + 24), Double door

27

-

-

... More
12 way (4 + 36), Double door

27

-

-

... More
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)8 way, Double door

12

-

-

... More
12 way, Double door

10

-

-

... More
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single Pole

832

-

-

... More
Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40A DP MCB

22

-

-

... More
S/F DP RCCB : Supplying and fixing following rating, double pole, (single phase and neutral), 30 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 30 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 Amps

22

-

-

... More
S/F FP MCB Isolator: Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40A FP MCB

54

-

-

... More
S/F FP MCB Isolator: Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63A FP MCB

27

-

-

... More
S/F 4P RCCB : Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 30 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps

67

-

-

... More
S/F 4P RCCB : Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 30 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 amps

43

-

-

... More
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.

100

-

-

... More
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 20 mm

1000

-

-

4500

-

-

500

-

-

200

-

-

... More
Supplying of Recess mounted light fixture as superior CRCA sheet housing required in 2'x2' fixture complete as required Bajaj : BZRSQL36 GZ WH or equivalent.

258

-

-

... More
Supplying of surface mounted light fixture as superior CRCA sheet housing required in 2'x2' fixture complete as required Bajaj : BZSSQL 36 W or equivalent.

201

-

-

... More
Supplying of Recess mounted light fixture LED with 1'x1' luminiare with, CRCA sheet housing complete as required. Bajaj - BZRSQL 18 W or equivalent.

53

-

-

... More
Supply of surface mounted 1'x1' LED luminiare with CRCA sheet housing complete as required. Bajaj: BZSSQL 18 W or equivalent.

56

-

-

... More
Supplying of Recess mounted light fixture suitable for 1 No. 12 watt LED light complete as required. Bajaj Make: BZSLH 12W Dovee LH or equivalent.

128

-

-

... More
Supplying of Surface mounted mirror optics light fixture suitable for 1 No. 18 watt LED Light complete as required. Bajaj : BZSSQL 18 W or equivalent.

20

-

-

... More
Supplying of Up & Down light fixture suitable for PAR 1 No. 9 watt LED light complete as required. Bajaj Make: LED UP LIGHT BLWUP 9 WLED or equivalent.

40

-

-

... More
Supplying of Planter light fitting miniature integral flood light luminaire 9W LED with pressure die cast aluminium housing (IP65) complete as required. Bajaj : BGSBL 9 W LED or equivalent.

32

-

-

... More
Supplying of Surface mounted light fixture suitable for 1 No. 10 Watts LED bulk head lamp complete as required. Bajaj : BIBWP10 W or equivalent.

60

-

-

... More
Supplying of Mirror light fixture suitable for 1 No. 5 Watts LED light complete as required. Bajaj Make: BCLSB 05 W or equivalent.

40

-

-

... More
Supplying of Wall mounted tube light fixture suitable for 1 No. 18 Watts LED light complete as required.LED closed batten extruded aluminium housing fitted with eng plastic and end plates complete as required. Bajaj : BCLSB 18 W or equivalent .

250

-

-

... More
Supplying of Surface mounted Industrial type light fixture suitable for 40 W LED light or equivalent. CRCA steel sheet housing comprising of white LED's/ opal diffusser is supported by CRCA end plates complete as required. Bajaj Make: BICDP 40W LED or equivalent.

70

-

-

... More
Supplying of Surface Mounted Flood light luminaire with Cast Aluminium Housing & toughened glass cover complete as required. Bajaj Make: BJFL 80 W LED FLOOD or equivalent / Epoxy white powder coated pressure die cast aluminium housing / epoxy cream white powder coated die cast frame with heat resistant toughned glass complete as required.

27

-

-

... More
Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 amps “C” curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.

26

-

-

... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).

1090

-

-

... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.

742

-

-

... More
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.

40

-

-

... More
Supplying and fixing stiff pendent with 300 mm long, 20 mm dia X 1.6 mm thick steel conduit, aluminium cast back plate and brass holder complete, including wiring the down rod with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and painting etc. as required.

11

-

-

... More
Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required.

5

-

-

... More
Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.

800

-

-

... More
Numbering of ceiling fan/ exhaust fan/ fluorescent fittings as required.

2500

-

-

... More
Providing and fixing M.S. fan clamp type I or II of 16 mm dia M.S. bar, bent to shape with hooked ends in R.C.C. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete.

220

-

-

... More
Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing.

220

-

-

... More
Supply of 1200 mm. dia. Ceiling Fan complete as required.

220

-

-

... More
Supply of 900 mm. dia. Ceiling Fan complete as required.

20

-

-

... More
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.

440

-

-

... More
Supply of LPI ESE Stormaster type Lightning Protection complete with the Lightning Air Terminal - Configured as a Spheroid which is comprised of separate electrically isolated 4 panels surrounding an earthed central finial. The Insulation material used to electrically isolate the panels (Stainless steel) shall be comprised of a base polymer which provides high Ozone & UV resistance with a di-electric strength of 24-38 KV/mm tested as per NFC 17-102 & IEC 60-1:1989. As per NF C 17–102, the ESE air terminal shall be tested with the “Switching Impulse Voltage” of 700 KV and “Direct Voltage” of 70 KV and certified by an international testing laboratory. The early streamer emission terminal shall be tested & certified by CPRI (Central Power Research Institute), Govt of India for the Impulse current of 45 KA (8/20 micro sec) with 5 positive & 5 negative impulse. The ESE Stormaster terminal shall be recommended from DGMS (Director General of Mines Safety), Govt of India. The ESE terminal shall not have any electronic circuit or any batteries inside to operate and it shall not depend on wind or solar to operate. The ESE terminal shall be tested and certified by any international laboratory as per IEC 60-1:1989 for an impulse current (8/20 micro sec) of more than 160 KA. The serial number displayed on theese lightning arrester shall be duly supported with the "certificate of country of origin" issued and duly sealed by the respective country (exported)" chember of Commerce & Industry" indicating the serial number of the product supplied. The ESE terminal shall offer protection radius of mtrs at Level III / Standard protection and perferably to bemounted on the roof top & centre. Make: LPI (Australia) Model: Stormaster 30 SS - 48mtrs (Level I / High Protection) (8/20 micro sec) with 5 positive & 5 negative impulse. The ESE Stormaster terminal shall be recommended from DGMS (Director General of Mines Safety), Govt of India. The ESE terminal shall not have any electronic circuit or any batteries inside to operate and it shall not depend on wind or solar to operate. The ESE terminal shall be tested and certified by any international laboratory as per IEC 60-1:1989 for an impulse current (8/20 micro sec) of more than 160 KA. The serial number displayed on the ese lightning arrester shall be duly supported with the "certificate of country of origin" issued and duly sealed by the respective country (exported)" chember of Commerce & Industry" indicating the serial number of the product supplied. The ESE terminal shall offer protection radius of mtrs at Level III / Standard protection and perferably to bemounted on the roof top & centre. Make: LPI (Australia) Model: Stormaster 30 SS - 48mtrs (Level I / High Protection) or equivalent.

2

-

-

... More
Supply of Mast (G.I. pipe of 5 mtrs height) for mounting the terminal & adaptor with the Stormaster ESE Air Terminal along with supporting stray wires, etc.

4

-

-

... More
Supply of advance maintenance free Chemical Gel Earthing of Dual Pipe Technology (GI) of 3 mtr long, 80mm dia JK CHEMRODE filled with highly conducting metallic compounds with the permanent sealings at the both the ends with the lead terminal at the top along with 50 Kgs of RESLOW (mixture Sulphate, Silica, Alumina, Iron Oxide, Titanium Oxide, Calcium Oxide, Potassium Oxide, Chloride, Nickel Oxide, Magnesium Oxide, Sodium Oxide, Zinc Oxide, etc) Resistance Lowering Grounding Minerals. The loss on ignition by mass of the chemical compound RESLOW is less than 20%. The chemical compound RESLOW is tested and certified by any International accredited and BIS (Bureau of Indian Standards) accredited laboratory. The testing laboratory is an ISO 9001 &ISO 14001 certified. Make: JK Model: 380 or equivalent.

8

-

-

... More
Supply of heavy duty weather proof environment friendly polyplastic earth pit chamber with cover of autolocking facility with the following dimensions - 254mm dia (top), 330mm dia (bottom) and 260mm height. 4 knock-out openings are provided for the easy interconnection of earth strips between the earth pits to form a grid.

8

-

-

... More
Supply of Lightning Strike Recorder - 7 digits mechanical display to record the lightning current in an IP 67 enclosure with the minimum sensitivity of 1500A & maximum capacity of 220 KA (8/20 micro second waveform). The recorder shall be of non-resettable type with the electro-mechanical display. No LCD screen is used as it may depend upon the battery life to energize the LCD. The lightning strike recorder is duly tested & certified inline with the ese lightning arrester in an international labortory for an impulse current (8/20 micro sec) of more than 160 KA as per IEC 60-1:1989 standard. The lightning strike recorder is tested & certified by CPRI (Central Power Research Institute), Govt of India for the Impulse current of 45 KA (8/20 micro sec) with 5 positive & 5 negative impulse. Make: LPI (Australia) Model: LSR1 or equivalent.

4

-

-

... More
Supply of down conductor of 70 sq.mm single core insulated flexible copper cable with necessary accessories, etc.

200

-

-

... More
Supply of Test Link Joint Kit in a IP 55 weather proof enclosure of suitable dimension etc. complete as required.

4

-

-

... More
Installation cost of total Advance Lightning Protection System.

4

-

-

... More
Supply and fixing of AVIATION OBSTRUCTION light with red colour LEDs, intensity 30 candela in one direction, total intensity 600 candela (Type - L1 - 300) complete with fixing arrangement as per site conditions. (Bajaj : 020115 BJAOL 2 ES or equivalent.

2

-

-

... More
Supplying and fixing of Modular Type RJ-11 telephone socket outlet in the existing MS/GI sheet box and cover plate complete as required:- Single RJ-11 in One Plate.

220

-

-

... More
Double RJ-11 in One Plate.

15

-

-

... More
Supplying and drawing following pair 0.6 sq mm FR PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. 2 Pair

6800

-

-

... More
Supply and installation of KRONE connector type main telephone tag block of following sizes in sheet metal enclosure of suitable dimensions fabricated out of 16 SWG sheet steel with castle key lock, hinged type cover including termination of telephone cables, making connections, painting of box etc. complete as required:- 5 Pairs

2

-

-

... More
10 Pairs

5

-

-

... More
20 Pairs

11

-

-

... More
50 Pairs

2

-

-

... More
300 Pairs

1

-

-

... More
Supplying, laying, testing and terminating with soldered terminals on both ends for 0.6 mm dia PVC insulated, PVC sheathed armoured annealed tinned copper conductor, telephone Cables with GI wire / strip armouring generally conforming to ITD specification S/WS-113C & S/WS-114 on surface / recessed / false ceiling / cable Tray / GI pipe / Hume pipe etc. complete as required:- 5 Pairs

210

-

-

... More
10 Pairs

200

-

-

... More
20 Pairs

555

-

-

... More
50 Pairs

145

-

-

... More
Supplying, installation, testing and commissioning of EPABX System (Communication System), equipped with 20 analog trunk line + 256 analog extn., conference call, call waiting, call forwarding with all latest features and many more complete as required.

1

-

-

... More
Supplying and fixing of Modular type TV Co-axial socket outlet in the existing MS / GI sheet box and cover plate complete as required:-

10

-

-

... More
Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required.

500

-

-

... More
Supplying and drawing co-axial TV cable RG-11 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheathed including heavy duty 2mm thick in the existing surface / recessed steel / PVC conduit as required.

400

-

-

... More
Supply and fixing of TV Splitter in the existing MS / GI box including making connections with thimbles/ connectors etc. as required. Four nos. outgoing

6

-

-

... More
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. 1 run of cable

6660

-

-

... More
Supplying, installation, testing & commissioning of RJ-45 Flush mounted information outlets wired according to T568A/B standard with face plate in new G.I./Zinc cromated box complete with box, inner plate and modular type front plate modular box. complete as reqiuired:- Single outlet

150

-

-

... More
Double outlets

36

-

-

... More
Supply, installation, testing and commissioning of Main Control panel with 12 Zones expandable to 14 zones, compliant to IEC 60849 Evacuation Standards, fully supervised and with digital pre-recorded messages, with Cat-6 connectivity complete with connections etc. complete as required.

1

-

-

... More
Supply, installation, testing and commissioning of Voice Alarm Call Stations with mounting box etc. complete as required.

1

-

-

... More
Supply, installation, testing and commissioning of Call Station Keypad with mounting box etc. complete as required.

1

-

-

... More
Amplifiers :- Supply, installation, testing and commissioning of Booster Amplifier 480 Watt complete with connections, connecting wires etc. complete as required.

8

-

-

... More
Supply, installation, testing and commissioning of Booster Amplifier 240 Watt complete with connections, connecting wires etc. complete as required.

5

-

-

... More
Speakers :-Supply, installation, testing and commissioning of False Ceiling Mounted High Quality Polycarbonate 6 Watt Ceiling Speaker with connections, connecting wires etc. complete as required.

582

-

-

... More
Supply, installation, testing and commissioning of Volume Control complete with mounting box, cover etc complete as required.

34

-

-

... More
Music Source:- Supply, installation, testing and commissioning of All-in-one (Music Source) complete with connectors etc. as required.

1

-

-

... More
Equipment Rack :- Supply, installation, testing and commissioning of Equipment Rack for housing Control Equipment, Amplifiers and Music Source etc. complete as required.

1

-

-

... More
Supplying and drawing of 1 pair 48/.24 (1.5 sq.mm), twisted, stranded annealed electolytic copper conductor, colour coded, PVC sheathed and insulated FRLS wire, in existing recess / surface ISI Marked Heavy Gauge PVC conduits including connections etc. complete as required.

8000

-

-

... More
Supply, installation, testing & commissioning of Analogue Addressable Microprocessor Fire Alarm Control Panel supervised, modified two stage type with software package for programming based 10 loop fire alarm control panel expandable up to 12 loop & capable of taking minimum 125 detectors and 125 devices per loop like MCP, Strobes, Control Modules, Monitor Modules, response indicators and shall contain central processing unit, LCD display min 960 character with message transfer protocol arrangement to PA system sitting on the main rail of the panel along with microphone fire fighters telephone system and jack provisions for telephone instruments on the same platform and shall be of the same make as per the specification, complete with battery backup of 24 hours operation and 30 minutes alarm operation, with battery charger etc. The system shall have provision to integrate with life safety facilities i.e HVAC, lift or elevator by providing NO/NC contacts, BMS compatibility shall through MODBUS/ BACnet protocol. Panel shall be compatible for DC controllers & peer to peer networking on Fire Cable and Optic Fibre. The Panel shall be UL, FM Listed. 10 Loop expandable to 12 Loop

1

-

-

... More
Supply, installation, testing & commissioning of UL/EN listed Repeater Panel with minimum 960 characters backlit LCD display & with event and audiable status LED's, scroll buttons to view additional events, local sounder and provided in its own enclosure..

2

-

-

... More
Supply, installation, testing & commissioning of UL/CE listed Intelligent addressable Multicriteria Detector with base built-in isolator for distributed intelligence and electronic addressing.

69

-

-

... More
Supply, installation, testing & commissioning of UL/CE listed Intelligent addressable Photoelectric Smoke Detector with base built-in isolator for distributed intelligence and electronic addressing.

405

-

-

... More
Supply, installation, testing & commissioning of UL/CE listed Intelligent addressable Photoelectric Sounder based Smoke Detector with base built-in isolator for distributed intelligence and electronic addressing.

20

-

-

... More
Supply, installation, testing & commissioning of UL/CE listed Intelligent addressable Heat Detector with base built-in isolator for distributed intelligence and electronic addressing.

30

-

-

... More
Supply, installation, testing & commissioning of UL/CE listed Intelligent addressable Manual Call Point / Pull Station.

28

-

-

... More
Supply, installation, testing & commissioning of Addressable Hooter of intensity minimum 90db suitable for Alarm siren.

28

-

-

... More
Supply, installation, testing & commissioning of UL/CE listed addressable Control Module.

40

-

-

... More
Supply, installation, testing & commissioning of UL/CE listed addressable Monitor Module.

30

-

-

... More
Supply, installation, testing & commissioning of Response Indicator on wall/ceiling including metallic box etc complete as required.

20

-

-

... More
Supply, installation, testing & commissioning of 20 mm GI flexible pipe including end coupler complete as required.

120

-

-

... More
Supply, installation, testing & commissioning of UL/CE listed Intelligent addressable Photoelectric Smoke Detector above false ceiling with base built-in isolator for distributed intelligence and electronic addressing.

70

-

-

... More
Supply, installation, testing & commissioning of following sizes of standard copper conductor PVC insulated armoured cables of 1.1 KV grade complete as required. 2 x 1.5 Sq. mm.

600

-

-

... More
Supply, installation, testing & commissioning of following sizes of standard copper conductor PVC insulated armoured cables of 1.1 KV grade complete as required. 4 x 1.5 Sq. mm.

1500

-

-

... More
Supply, installation, testing & commissioning of UL/CE listed addressable Control Relay Module.

50

-

-

... More
ANALOG CLOSE CIRCUIT CAMERA SYSTEM (CCTV SYSTEM) Supply, installation, testing and commissioning of 1/4" CCD Indoor Dome Type Camera, minimum 540 TV lines with sensitivity down to 1.5 lux, 3.5 - 8 mm lens color cameras with Camera Mounts and all Ancillary equipment & all accessories duly mounted in ceiling / wall / false ceiling with suitable arrangement as per the requirement i/e connecting and setting the field of veiw and configuring the cameras on the CCTV system as per the location and as per technical specifications complete as required. Security Cameras

75

-

-

... More
PTZ Type Outdoor Weatherproof Cameras(IP-66): Supply, installation, testing and commissioning of 1/4" CCD Outdoor Highspeed Integrated Dome Type Camera, minimum 480 TV lines and sensitivity down to 1.0 lux, minimum 36-X color cameras, lens, Camera Mounts and all ancillary equipment & accessories duly mounted in Ceiling / Wall / false ceiling with suitable arrangement as per the requirement i/c connecting and setting preset views and configuring the cameras on the CCTV system as per the location and as per technical specifications complete as required.

5

-

-

... More
Fixed Type Weather Proof Cameras (IP 66): Supply, installation, testing and commissioning of 1/3" Colour Fixed C/CS Mount Camera with minimum 540 TVL resolution 5 to 50 mm Varifocal lens in IP66 Rated weatherproof enclosure with all Ancillary equipment & all accessories duly mounted in Ceiling / wall / false ceiling with suitable arrangement as per the requirement i/c connecting and setting the field of view and configuring the cameras on the CCTV system as per the location and as per technical specification complete as required.

12

-

-

... More
Digital Video Recorder: Supply, installation, testing and commissioning of 16 channel DVR with minimum 4 TB, and shall have minimum storage of 30 days internal Hard Disk, DVD writer and as per technical specifications complete as required.

6

-

-

... More
Multifunction Joystick/Keyboard: Supplying, installation, testing and commissioning of Multifunction Keyboard with Joystick Controller with LCD display to control the Multiplexers / NVR and to Pan/Tilt/Zoom the cameras connected to the CCTV system complete with hardware connectors/interfaces for connections with the matrix switchers, recorders, complete as per technical specifications complete as required.

3

-

-

... More
Colour Monitors: Supplying, installation, testing and commissioning of 50" sizes with minimum 480 TV lines resolution, non-stop viewing type colour monitors to view the output from Multiplexer / DVR / Camera etc. complete with cords and power supply and as per technical specifications complete as required.

6

-

-

... More
Supplying, installation, testing and commissioning of Metallic & powder coated Enclosures / Racks for housing following items complete with cable managers, cable ties etc. as required:- Wall mounted metallic brackets suitable for monitors.

3

-

-

... More
18 Unit Wall Mounted Rack including power strip with spike arrestors suitable for Network Video Recorders.

1

-

-

... More
Wiring: Supply and drawing of following annealed tinned copper conductor of size 7/0.4 mm dia. With Polyethylene dielectric, shielded with copper braiding / tinned copper braiding and overall PVC sheathed in existing recess/surface conduits including connections etc. complete as required:- RG-11 Coaxial cable

7200

-

-

... More
Supplying and drawing of twin twisted 1.5 sq mm multi-stranded (30/0.25) flexible copper conductor 1.1 KV conforming to IS 694/1990 wire in existing recess/surface conduits including connections etc. complete as required.

300

-

-

... More
SUB-STATION WORK HT SINGLE PANEL 11KV H.T. Single Panel Board Supply, installation, testing & commissioning of a Single Panel totally enclosed sheet steel clad floor mounting, vermin proof, fully interlocked horizontal isolation, extensible, horizontal draw out, air insulated, metal clad switchboard having single / double isolation features complete with circuits as detailed below. The switchboard shall be complete with necessary PVC insulated copper busbars, small wiring, labels, cable eyes, cable termination to receive XLPE cables, foundation bolts and suitable for operation on 11 kV 3 phase, 50 cycle, earthed system with a rupturing capacity of 350 MVA at 11 KV as per specification. Incoming panel equipped with 1- Air insulated metal clad housing 1- Set of 3 phase PVC insulated copper busbars 630 amps rating. 6- Single pole cluster type isolating contacts i.e. plug and switches. 1- Triple pole draw out truck mounted 350 MVA, 630 amps, 11000 volts Vacume Circuit Breaker fitted with arc control devices. 1- Trip free motor spring charged closing mechanism complete with necessary auxiliary switches, emergency hand trip device and mechanical 'OFF' & 'ON' indicator. 1- 24 volt DC shunt trip coil 1- 24 volt DC closing coil 1-230 volt AC supply for spring charge motor 3- Duel core Cast resin Current transformers of ratio 100/50/5A, 15 VA burden Class 5P10 for protection. And class 0.5 for metering. 3- 1 Phase cast resin horizontal draw out line potential transformer ratio 11 KV/110 volts, connected star/star with HV and LV connections, H.V. and L.V. fuses, isolating plugs for H.V. and L.V. connection. 1- Strip heater to prevent absorption of moisture The instrument and relay panel fitted with : 1- Square Digital voltmeter of 96 x 96 mm 0-15000 volt. 1-Square Digital Ammeter of 96 x 96 mm 0-200 amps. 1 – Digital frequency meter 1 - Digital solid state Trivector meter for kV, Amp, kW, kVAr, kVA, kWh, kVAh, kVArh, pf, amp-h, Hz measurements (communicable). 1- Triple pole Microprocessor IDMT overcurrent & earth fault relay with two outer elements connected for overcurrent protection and the middle element for earth fault protection overcurrent setting 50% - 200% Earth fault setting 20% - 80% (51 and 51N). 1 – Circuit breaker control switch for electrical (T/N/C) 1- Master trip relay (86) (communicable) 1- Anti pumping relay (94) (communicable) 1-Grid phase relay (communicable) 1- Set of Red/Green indicating lamps for close and open position 1- Amber indicating lamp for auto trip 1- Clear indicating lamp for trip circuit healthy. 1- Set of white indicating lamps one per phase. 1- Blue indicating lamp for spring charged. 1- Push button on front door for emergency trip. 1- Cable box suitable for cable termination to receive 11 KV XLPE Cable 3 Core 300 Sq. mm. 1 – Hooter Voltage surge supperssor Twelve (12) window Audio / Visual solid state Annunciator (Minilec/ PIC make)-1 Set. Test, Accept and reset push buttons for Annunciator-3 Sets. The Breaker shall trip if the DC supply is not healthy. 1- 1 set of ferrules, fuses, limit switch and wiring as required. The switchboard shall be complete with earth bus, all interconnections, labels wiring, etc as required.

1

-

-

... More
TRANSFORMERS - (Indoor Dry TYPE) Design, Manufacture, Supply, testing, Packing, Transportation and supervision for installation, testing & commissioning at site of 1250 KVA 3 phase, 11 / 0.433 KV, 50Hz step down dry type Cast Resin transformer copper wound with Dyn-11 connection and neutral brought out for earthing. The transformer shall be provided with (+) 5% and (-) 15.0 % ON load tap changer with RTCC on HT side in step of 1.25 % each. HT side cable termination box shall be suitable for 1 No. 11 KV, 3 C x 240 sqmm XLPE aluminium (E) cable and LT side terminal box shall be suitable for terminating 2000 amp 4P aluminium conductor air insulated busduct. The transformer shall be supplied with all accessories complete as per specifications. (Transformer shall be Indoor Type) 1250 KVA Dry Type Transformer All instruments / Relays / CT. terminals/ Contact wiring to be done up to Marshalling box. The Transformers shall be with ON LOAD Tap Changer & RTCC facility. The Rates shall include the rates for foundations as per the manufacturer's specification. Installation shall be done by the electrical contractor in the presence of authority engineer deputed by the supplier. The supplier shall certify that the Transformer has installed as per norms. Unloading of the Transformer shall be in the scope of electrical Contractor.

1

-

-

... More
The Fees for the liasioning, inspection and approval of the drawing and installation from Electrical Inspector and Local Authority, etc. complete as required for satisfatory function of the installation of 1 x 1250 KVA Dry Type Transformers.

1

-

-

... More
Supply of the following sizes of 11 KV XLPE AL Earthed armoured cable in cable trenches or in ducts over a bed of sand and covering with bricks as per specifications including excavation of trenches and back filling complete as required. 11 KV, 3C x 300 Sq. mm XLPE Aluminium cable

100

-

-

... More
Laying, effecting proper connections, testing and commissioning of the following sizes of 11 KV XLPE AL Earthed armoured cable in cable trenches or in ducts over a bed of sand and covering with bricks as per specifications including excavation of trenches and back filling complete as required. 11 KV, 3C x 185/300 Sq. mm XLPE Aluminium cable

100

-

-

... More
HT CABLE TERMINATIONS Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required : 300 sq. mm.

3

-

-

... More
Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required : 300 sq. mm.

1

-

-

... More
ISOLATOR PANEL , MAIN LT PANEL & CAPACITOR PANEL Supply, installation, testing and commissioning of 35 MVA rupturing capacity of outdoor type (IP-65) fabricated out of 14 SWG MS sheet with MS 100 mm channel base frame free standing type weather, dust and vermin proof by provision of gasket beneath all cover and door suitable for operation on 3 phase 4 wire 415 volt 50 Hz, AC supply. The ACB/MCCB switches shall be fully insulated supported on hygroscopic insulated and covered with heat shrinkable colour coded sleeves. The panel shall be suitable for 1250 KVA Transformers having 2000 A TP+N MDO type ACB (50 KA) and should incorporate the following panel mounting including connections, interconnections with proper earthing terminals, danger plate, painting etc. complete as required. 4 pole ACB should have 100% neutral rating. Cable entry shall be as per Site conditions. The following provisions shall be required to be made in the switchboard detailed below: Suitable tinned aluminium extension links for incoming/outgoing cables shall be provided wherever required. All ACB’s shall have all standard accessories such as CT’s, Arc Chute, Safety Shutters etc. The ACB release shall have LED indications to indicate each type of fault. All ACB shall be microprocessor based (O/L, S/C & E/F protection). All ACBs should be Icu=Ics=Icw

1

-

-

... More
Supply, installation, testing & commissioning of LT Panel fully compartmentalized cubical type sheet steel clad floor mounted totally enclosed extensible on both sides switch board suitable for use on 415 V 3 phase 4 wire 50 c/s System having 50 KA fault capacity, housed with incoming and outgoing aluminium bus bars interconnection etc. with indication lamps, accessories etc. as required and complete with following incoming and outgoing switchgears with protection and metering etc. as per specification and schematic diagram. (Note : The fault withstanding capacity shall be 50 kA for one sec. Earth bus shall be part of the panel). Incoming Breakers : 1 Nos. 2000A motor operated spring charged Four Pole, EDO, ACB 50 KA (for 1 Nos. 1250 KVA Transformer feeder) of drawout pattern arrangement for cables (10 x 1C x 630 sq.mm) connection on incoming side and busbar connection on outgoing side. micro processor based O/C, S/C & E/F releases; 6 NO + 6 NC auxiliary switch contacts & ON/OFFTrip R/Y/B indicating lights with necessary auxiliary change over contactor. 2 Nos. 800 amp FP MCCB 50 KA (ics=icu) with adjustable thermal magnetic release having over current & short circuit & earth fault protection. Bus coupler : 2 Nos. 2000A motor operated spring charged Four pole, EDO, ACB 50 KA with protection releases, suitable for Bus bar connections and fitted with 6 NO + 6 NC auxiliary switch contacts and ON/OFF/Trip indicating lights with necessary auxiliary changeover contactor. Interlocking: The bus coupler shall be electrically & mechanically interlocked with all incoming transformer breakers & DG Set breakers in such a way that at any one time two supplies should not get mixed up. (As per scheme approved) Bus Bars : 2 Sets of 2000 Amp TP+N busbars of high conductivity electrolytic quality aluminium alloy. Bus bars shall be colour coded and insulated by heat shrinkable sleeves & clip on shrouds for joints. The bus bar sizing calculations shall be submitted for approval, after considering all derating factors. (Neutral Bus Bar shall be of 50% rating) Metering and Indication: Each incoming ACB shall be provided with the following : 1 Set of phase indicating lamps with 2A SP MCB back up . 1 No. T-N-C breaker control switch. (Trip / Neutral / Close) Each Transformer Feeders / DG Set feeders : Multifunction meter for Voltmeter, Ammeter, Frequency Meter. kW, kWH & PF Meter with RS485/RS232 communication port, ON/OFF/Trip/ Spring charged/ Trip Circuit Healthy Lamps, CT's. 1 nos. 2000/5A for 1 x 1250 KVA transformers and 2 nos. 800A/5A for each 500 KVA DG Set as required, phase indicating lamps suitable for 415 V/AC with 2 A SP MCB back up. Protective Devices for Incomers : Separate CT's shall be provided for protective and measuring system. CT's shall be suitable for capacitor bank and power factor meters etc. The incoming ACB shall be provided with the following protective devices: Each Transformer Feeders: 24 V DC Shunt trip coil. Trip circuit supervission Relay Master Trip Lockout Relay 1 Set of suitable rating CTs, CL-1.0 for APFCR relay. 2 O/C + 1 E/F Relay ( with suitable rating CTs, CL-5P10 Section - A 10 Nos. Three phase Digital Type KWH Energy Meter , with all necessary power wiring including supply of suitable rating energy meter Windows for meter reading including required wiring from bus bars to meter & meter to MCCBs. Terminal block for looping DC supply to each meter. 2 No. 630 Amp TP+N MCCB 50 KA (ics=icu) with adjustable thermal magnetic release having over current & short circuit & earth fault protection. 4 No. 160 Amp TP+N MCCB 50 KA (ics=icu) with adjustable thermal magnetic release having over current & short circuit & earth fault protection. 10 Nos. 125 Amp TP+N MCCB 50 KA (ics=icu) with adjustable thermal magnetic release having over current & short circuit & earth fault protection. 1 No. 125 Amp FP MCCB 50 KA 2 Nos. 100 Amp TP+N MCCB 50 KA (ics=icu) with adjustable thermal magnetic release having over current & short circuit & earth fault protection. 1 No. 63 Amp TP+N MCCB 36 KA (ics=icu) with adjustable thermal magnetic release having over current & short circuit & earth fault protection. Section - B 8 Nos. Three phase Digital Type KWH Energy Meter , with all necessary power wiring including supply of suitable rating energy meter Windows for meter reading including required wiring from bus bars to meter & meter to MCCBs. Terminal block for looping DC supply to each meter. 2 No. 800 Amp TP+N MCCB 50 KA (ics=icu) with adjustable thermal magnetic release having over current & short circuit & earth fault protection. 4 No. 400 Amp TP+N MCCB 50 KA (ics=icu) with adjustable thermal magnetic release having over current & short circuit & earth fault protection. 4 No. 250 Amp TP+N MCCB 50 KA (ics=icu) with adjustable thermal magnetic release having over current & short circuit & earth fault protection. 6 No. 100 Amp TP+N MCCB 50 KA (ics=icu) with adjustable thermal magnetic release having over current & short circuit & earth fault protection. PLC AUTO LOAD MANAGEMENT 1 no. 32-bit microprocessor based PLC suitable for and complete with interfacing with PCC module mounted on DG Set including rating and for Sensing of Mains load during failure, Auto Changeover/ Interlocking and Auto Load Searching & Auto Load Management of the following and as per Logic and requirements in the schematic drawings. The system shall generally include the following but not restricted to the same and shall be complete so as to achieve the intent of the same as per requirements. Programmable Logic Controller (PLC) of Siemens/ Allan Bradley make System configuration for PLC management of 2 nos. DG Set Auto control mode through PLC Manual override for solo operation of DG Set 1 nos. Incomings from 1 nos. 1250 KVA Transformers 2 nos., 500 KVA DG Set 1 nos. Bus coupler Manual Mode 3 sets of 3 Indicating lamps "Load on Set" "Load on Mains" "Set fails to start". Emergency stop push button for each DG Set and Main Supply from Main LT Panel Engine Start / Stop / Push Button for each DG Set PLC / Manual selector switch DG Set selector switch 12 window annunciator for each DG Set faults 1 no. common hooter PLC shall provide for each DG Set Engine Start / Stop Indication for "Load on set" "Load on Mains" "Set fails to start" "Low Oil Pressure" "Overspeed" "Low Fuel". The PLC shall provide auto mains failure, auto change-over, auto load management for 2 nos. 500 KVA DG Set and 1 nos. incomings from Transformers + 1 nos. bus coupler by automatic closing and opening of the mains, alternator and bus section circuit breakers on the Main Panel switchboard for automatic operation as per Logic detailed in the schematic drawing. The PLC shall provide Interlocking as per schematic drawings. Main Processor Unit Rack Power Supply Unit I/O Slot Rack Digital input modules as required Digital output modules as required Analogue input modules as required EEPROM Auxiliary contactor and relays as MCB’s AC & DC as required One stabilized power supply 10 amp 230/24 volt DC for PLC with transformer, rectifier etc. 2 DC ON and OFF indication DC ammeter and DC voltmeter 1 no. Online UPS 1 KVA 15 minutes backup 230 volt ±15% (Invensys / APC) 1 set PC to PLC communication cable 1 set PC to PLC communication card 1 set Communication Cable and accessories MIMIC diagram with LED lights Man Machine Interface (MMI) Computer based PLC software, computer based Man Machine Interface graphic software development for monitoring, control, alarm annunication and historical trends. The software to be approved before finalization. The item have been covered in bill of material. The system to communication with 100% protection. Nothing extra shall be payable for any deviation on this account. The communication card / software required for interfacing PCC, PLC & PC shall be provided by DG Set manufacturer (RS-485/232) The 12 window annunciator for each DG Set shall have following faults on Main Panel DG Set incomer. Low Lube Oil Pressure Over Speed High Water Temperature Emergency Shut Down Raw Water Pump Trip CT Fan Trip Under Voltage Over Voltage Reverse Power Breaker Trip The fault annunciator for PLC management have following indication on PC screen and annunciation DG Set 1/DG Set 2 (any one) fails to manage load DG Set 1/ DG Set 2 (any one) fails to start DG Set 1/DG Set 2 (any one) fails to close.DG Set 1/DG Set 2 (any one) neutral discrepancy.B/C-1 ACB/MCCB fails to close B/C-1ACB/MCCB ONPanel Accessories Earth bus FiltersExhaust fan Panel lightDoor switch Space heater The Switchboard shall be extensible as per drawing enclosed complete with all Interconnections, Inter Panel Wiring from PLC to DG Set / TRAFO / BC / Breaker Risers, Internal Wiring, Labels etc. complete as required Main LT Panel Main LT Panel

1

-

-

... More
CAPACITOR PANEL :- 325 KVAR CAPACITOR PANEL : Design, manufacture, supply of 325 KVAR capacitor bank panel consisting of 325 KVAR Capacitor units (1x100 KVAR, 2x50 KVAR & 5x25 KVAR) in tier formation; housed in an integrated cubicle type, indoor type automatic switching 'ON' and 'OFF' control panel with dust and vermin proof hinged and lockable doors complete with interconnections, bonding to earth and painting (suitable for 400/440 Volts, 3 phase 50 Hz supply system). Enclosure of capacitor panel shall be liberally designed to take care of internal heat emission by capacitor unit without forced cooling and to limit the temperature rise with in permissible limit. However, louvers are allowed to facilitate extra cooling. Automatic switching "ON" and "OFF" with 8 steps automatic control relay on the control panel for 500 KVAR capacitor banks. Each panel consists of: Incoming 1 No. 800 amp TP MCCB 50 KA (ics=icu) with adjustable thermal magnetic release having over current & short circuit & earth fault protection. Bus Bar 1 Set of 1000 Amp TP busbars of high conductivity electrolytic quality aluminium alloy. TP 'electrolytic' Aluminium Bus Bars of suitable length. Bus bars shall be colour coded and insulated by heat shrinkable sleeves & clip on shrouds for joints. The bus bar sizing calculations shall be submitted for approval, after considering all derating factors. Indications Phase indicating lamps each backed up with 2 amp MCB and ON/OFF toggle switches. Correction Relay 8 step APFCR relay having facility to change the sequence of switching 'ON' the capacitor banks as required. The program of APFCR shall be re settable to enable sequance of ON/OFF of individual bank, so that the end unit of capacitor bank is not kept idle for long. Outgoings 1 No. 250A TP MCCB 50 KA (ics=icu) with adjustable thermal magnetic release having over current & short circuit & earth fault protection. 2 Nos. 125A TP MCCB MCCB 50 KA (ics=icu) with adjustable thermal magnetic release having over current & short circuit & earth fault protection. 5 Nos. 63A TP MCCB 50 KA (ics=icu) with adjustable thermal magnetic release having over current & short circuit & earth fault protection. 1 No. 300A AC3 of ML or equivalent capacitor duty contactors suitable for 100 KVAr Rating. 2 Nos. 200A AC3 of ML or equivalent capacitor duty contactors suitable for 50 KVAr Rating. 5 Nos. 70A AC3 of ML or equivalent capacitor duty contactors suitable for 25KVAr Rating. 1 No. 100 KVAR MPP capacitor bank with 7% D-tuned reactor filter and discharge resistor 2 Nos. 50 KVAR MPP capacitor bank with 7% D-tuned reactor filter and discharge resistor 5 Nos. 25 KVAR MPP capacitor bank with 7% D-tuned reactor filter and discharge resistor 16 Sets of 'RED' and 'GREEN' push buttons for manual operation of capacitors. Indicating lamp in each 100/50/25 KVAR capacitor chamber unit to indicate "ON/OFF" status of capacitor unit Push button to switch off the capacitor bank in manual and auto mode. OFF delay timer for manual mode Aux. Contactor as required 1 No. selector switch for Auto/Manual/Off All interconnections from the bus bars to individual MCCB and MCCB to contactor and contactor to terminal blocks for Automatic Switching "ON" and "OFF".

1

-

-

... More
Supply, installation, testing & commissioning of Sub-Panels, cubicle type, made out of 2 mm thick CRCA sheet, totally enclosed, IP-42, free standing, floor/Wall mounting, dust and vermin proof, indoor, compartmentalised, suitable for operation on 3 phase and neutral, 415 V, 50Hz AC system with busbars, including internal wiring with suitable size wires / cable, interconnection, duly powder coated painting etc. including supply & installation of following switchgears, metering instruments and accessories as per specifications. MAIN ELECTRICAL PANEL FOR ESSENTIAL LOADS INCOMING 630 Amps TP+N MCCB 35 KA (ics=icu) with adjustable thermal magnetic release having over current & short circuit & earth fault protection. 0-500 Volts digital volt meter shall be protected by 2 Amps TP MCB's. - 1 Set 0-600 Amps digital ammeter with 600/5 Amps 15 VA, CL 1 CTs . - 1 Set Phase indicating light shall be protected by 2 Amps SP MCB's. - 3 Set BUSBARS Electrolytic high conductivity aluminium three phase and neutral busbars rated at 800 amps having a maximum current density of 1.0 amp per sq.mm suitable to with stand symmetrical fault level of 35 M.V.A at 415 volts. The neutral busbar is to be of 50% capacity. OUTGOING 1 No. 160 Amps TP+N MCCB 35 KA (ics=icu) with adjustable thermal magnetic release having over current & short circuit & earth fault protection. 5 Nos. 125 Amps TP+N MCCB 35 KA (ics=icu) with adjustable thermal magnetic release having over current & short circuit & earth fault protection. 2 Nos. 100 Amps TP+N MCCB 35 KA (ics=icu) with adjustable thermal magnetic release having over current & short circuit & earth fault protection. 2 Nos. 100 Amps TP+N MCCB 35 KA (ics=icu) with adjustable thermal magnetic release having over current & short circuit & earth fault protection.

1

-

-

... More
MAIN ELECTRICAL PANEL FOR NON-ESSENTIAL LOADS INCOMING 250 Amps TP+N MCCB 35 KA (ics=icu) with adjustable thermal magnetic release having over current & short circuit & earth fault protection. 0-500 Volts digital volt meter shall be protected by 2 Amps TP MCB's. - 1 Set 0-250 Amps digital ammeter with 250/5 Amps 15 VA, CL 1 CTs . - 1 Set Phase indicating light shall be protected by 2 Amps SP MCB's. - 3 Set BUSBARS Electrolytic high conductivity aluminium three phase and neutral busbars rated at 300 amps having a maximum current density of 1.0 amp per sq.mm suitable to with stand symmetrical fault level of 35 M.V.A at 415 volts. The neutral busbar is to be of 50% capacity. OUTGOING 6 Nos. 100 Amps TP+N MCCB 35 KA (ics=icu) with adjustable thermal magnetic release having over current & short circuit & earth fault protection.

1

-

-

... More
ELECTRICAL FLOOR PANEL - 1 ELECTRICAL LIGHTING SUB-PANEL (Ground Floor) INCOMING 125 Amps TP+N MCCB 35 KA (ics=icu) with adjustable thermal magnetic release having over current & short circuit & earth fault protection. 0-500 Volts digital volt meter shall be protected by 2 Amps TP MCB's. - 1 Set 0-150 Amps digital ammeter with 150/5 Amps 15 VA, CL 1 CTs . - 1 Set Phase indicating light shall be protected by 2 Amps SP MCB's. - 3 Set BUSBARS Electrolytic high conductivity aluminium three phase and neutral busbars rated at 200 amps having a maximum current density of 1.0 amp per sq.mm suitable to with stand symmetrical fault level of 35 M.V.A at 415 volts. The neutral busbar is to be of 100% capacity. OUTGOING 1 No. 40 Amps DP MCB(10 KA) 5 Nos. 40 Amps 4P MCB(10 KA) 1 No. 63 Amps 4P MCB(10 KA)

2

-

-

... More
ELECTRICAL POWER SUB PANEL (GROUND FLOOR) BLOCK 'A' INCOMING 100 Amps TP+N MCCB 35 KA (ics=icu) with adjustable thermal magnetic release having over current & short circuit & earth fault protection. 0-500 Volts digital volt meter shall be protected by 2 Amps TP MCB's. - 1 Set 0-100 Amps digital ammeter with 100/5 Amps 15 VA, CL 1 CTs . - 1 Set Phase indicating light shall be protected by 2 Amps SP MCB's. - 3 Set BUSBARS Electrolytic high conductivity aluminium three phase and neutral busbars rated at 200 amps having a maximum current density of 1.0 amp per sq.mm suitable to with stand symmetrical fault level of 35 M.V.A at 415 volts. The neutral busbar is to be of 50% capacity. OUTGOING 5 Nos. 63 Amp FP MCB (10 KA)

2

-

-

... More
ELECTRICAL FLOOR PANEL - 2 & 3 ELECTRICAL LIGHTING SUB-PANEL (1 st & 2nd Floor) INCOMING 125 Amps TP+N MCCB 35 KA (ics=icu) with adjustable thermal magnetic release having over current & short circuit & earth fault protection. 0-500 Volts digital volt meter shall be protected by 2 Amps TP MCB's. - 1 Set 0-150 Amps digital ammeter with 150/5 Amps 15 VA, CL 1 CTs . - 1 Set Phase indicating light shall be protected by 2 Amps SP MCB's. - 3 Set BUSBARS Electrolytic high conductivity aluminium three phase and neutral busbars rated at 200 amps having a maximum current density of 1.0 amp per sq.mm suitable to with stand symmetrical fault level of 35 M.V.A at 415 volts. The neutral busbar is to be of 100% capacity. OUTGOING 2 No. 40 Amps DP MCB(10 KA) 5 Nos. 40 Amps 4P MCB(10 KA)

4

-

-

... More
ELECTRICAL POWER SUB PANEL (1ST & 2ND FLOOR) INCOMING 100 Amps TP+N MCCB 35 KA (ics=icu) with adjustable thermal magnetic release having over current & short circuit & earth fault protection. 0-500 Volts digital volt meter shall be protected by 2 Amps TP MCB's. - 1 Set 0-100 Amps digital ammeter with 100/5 Amps 15 VA, CL 1 CTs . - 1 Set Phase indicating light shall be protected by 2 Amps SP MCB's. - 3 Set BUSBARS Electrolytic high conductivity aluminium three phase and neutral busbars rated at 200 amps having a maximum current density of 1.0 amp per sq.mm suitable to with stand symmetrical fault level of 35 M.V.A at 415 volts. The neutral busbar is to be of 50% capacity. OUTGOING 5 Nos. 63 Amps FP MCB 10 KA

2

-

-

... More
ELECTRICAL LIGHTING SUB-PANELS -4 (3rd Floor) INCOMING 100 Amps TP+N MCCB 35 KA (ics=icu) with adjustable thermal magnetic release having over current & short circuit & earth fault protection. 0-500 Volts digital volt meter shall be protected by 2 Amps TP MCB's. - 1 Set 0-100 Amps digital ammeter with 100/5 Amps 15 VA, CL 1 CTs . - 1 Set Phase indicating light shall be protected by 2 Amps SP MCB's. - 3 Set BUSBARS Electrolytic high conductivity aluminium three phase and neutral busbars rated at 200 amps having a maximum current density of 1.0 amp per sq.mm suitable to with stand symmetrical fault level of 35 M.V.A at 415 volts. The neutral busbar is to be of 100% capacity. OUTGOING 4 Nos. 40 Amps 4P MCB (10 KA) 4 Nos. 40 Amps 4P MCB (10 KA)

2

-

-

... More
ELECTRICAL POWER SUB PANEL -4 (3RD FLOOR) INCOMING 100 Amps TP+N MCCB 35 KA (ics=icu) with adjustable thermal magnetic release having over current & short circuit & earth fault protection. 0-500 Volts digital volt meter shall be protected by 2 Amps TP MCB's. - 1 Set 0-100 Amps digital ammeter with 100/5 Amps 15 VA, CL 1 CTs . - 1 Set Phase indicating light shall be protected by 2 Amps SP MCB's. - 3 Set BUSBARS Electrolytic high conductivity aluminium three phase and neutral busbars rated at 200 amps having a maximum current density of 1.0 amp per sq.mm suitable to with stand symmetrical fault level of 35 M.V.A at 415 volts. The neutral busbar is to be of 50% capacity. OUTGOING 4 Nos. 63 Amps 4PMCB 10 KA

2

-

-

... More
ELECTRICAL LIGHTING SUB-PANEL - 1 (B-1 & B-2) INCOMING 125 Amps TP+N MCCB 35 KA (ics=icu) with adjustable thermal magnetic release having over current & short circuit & earth fault protection. 0-500 Volts digital volt meter shall be protected by 2 Amps TP MCB's. - 1 Set 0-150 Amps digital ammeter with 150/5 Amps 15 VA, CL 1 CTs . - 1 Set Phase indicating light shall be protected by 2 Amps SP MCB's. - 3 Set BUSBARS Electrolytic high conductivity aluminium three phase and neutral busbars rated at 200 amps having a maximum current density of 1.0 amp per sq.mm suitable to with stand symmetrical fault level of 35 M.V.A at 415 volts. The neutral busbar is to be of 100% capacity. OUTGOING 3 Nos. 40 Amps 4P MCB (10 KA) 2 Nos. 63 Amps 4P MCB (10 KA)

2

-

-

... More
ELECTRICAL POWER SUB PANEL B-1 & B2 INCOMING 100 Amps TP+N MCCB 35 KA (ics=icu) with adjustable thermal magnetic release having over current & short circuit & earth fault protection. 0-500 Volts digital volt meter shall be protected by 2 Amps TP MCB's. - 1 Set 0-100 Amps digital ammeter with 100/5 Amps 15 VA, CL 1 CTs . - 1 Set Phase indicating light shall be protected by 2 Amps SP MCB's. - 3 Set BUSBARS Electrolytic high conductivity aluminium three phase and neutral busbars rated at 200 amps having a maximum current density of 1.0 amp per sq.mm suitable to with stand symmetrical fault level of 35 M.V.A at 415 volts. The neutral busbar is to be of 50% capacity. OUTGOING 3 Nos. 63 Amps 4PMCB 10 KA

2

-

-

... More
ELECTRICAL LIGHTING SUB-PANEL 4th Floor INCOMING 125 Amps TP+N MCCB 35 KA (ics=icu) with adjustable thermal magnetic release having over current & short circuit & earth fault protection. 0-500 Volts digital volt meter shall be protected by 2 Amps TP MCB's. - 1 Set 0-150 Amps digital ammeter with 150/5 Amps 15 VA, CL 1 CTs . - 1 Set Phase indicating light shall be protected by 2 Amps SP MCB's. - 3 Set BUSBARS Electrolytic high conductivity aluminium three phase and neutral busbars rated at 200 amps having a maximum current density of 1.0 amp per sq.mm suitable to with stand symmetrical fault level of 35 M.V.A at 415 volts. The neutral busbar is to be of 100% capacity. OUTGOING 1 No. 40 Amps DP MCB (10 KA) 6 Nos. 40 Amps 4P MCB (10 KA)

2

-

-

... More
ELECTRICAL POWER SUB PANEL 4th Floor INCOMING 100 Amps TP+N MCCB 35 KA (ics=icu) with adjustable thermal magnetic release having over current & short circuit & earth fault protection. 0-500 Volts digital volt meter shall be protected by 2 Amps TP MCB's. - 1 Set 0-100 Amps digital ammeter with 100/5 Amps 15 VA, CL 1 CTs . - 1 Set Phase indicating light shall be protected by 2 Amps SP MCB's. - 3 Set BUSBARS Electrolytic high conductivity aluminium three phase and neutral busbars rated at 200 amps having a maximum current density of 1.0 amp per sq.mm suitable to with stand symmetrical fault level of 35 M.V.A at 415 volts. The neutral busbar is to be of 50% capacity. OUTGOING 5 Nos. 63 Amps 4PMCB 10 KA

2

-

-

... More
ELECTRICAL SUB-PANELS - ELECTRICAL LIGHTING SUB-PANEL 5th Floor INCOMING 125 Amps TP+N MCCB 35 KA (ics=icu) with adjustable thermal magnetic release having over current & short circuit & earth fault protection. 0-500 Volts digital volt meter shall be protected by 2 Amps TP MCB's. - 1 Set 0-150 Amps digital ammeter with 150/5 Amps 15 VA, CL 1 CTs . - 1 Set Phase indicating light shall be protected by 2 Amps SP MCB's. - 3 Set BUSBARS Electrolytic high conductivity aluminium three phase and neutral busbars rated at 200 amps having a maximum current density of 1.0 amp per sq.mm suitable to with stand symmetrical fault level of 35 M.V.A at 415 volts. The neutral busbar is to be of 100% capacity. OUTGOING 6 Nos. 40 Amps 4P MCB (10 KA)

2

-

-

... More
ELECTRICAL POWER SUB PANEL 5th Floor INCOMING 100 Amps TP+N MCCB 35 KA (ics=icu) with adjustable thermal magnetic release having over current & short circuit & earth fault protection. 0-500 Volts digital volt meter shall be protected by 2 Amps TP MCB's. - 1 Set 0-100 Amps digital ammeter with 100/5 Amps 15 VA, CL 1 CTs . - 1 Set Phase indicating light shall be protected by 2 Amps SP MCB's. - 3 Set BUSBARS Electrolytic high conductivity aluminium three phase and neutral busbars rated at 200 amps having a maximum current density of 1.0 amp per sq.mm suitable to with stand symmetrical fault level of 35 M.V.A at 415 volts. The neutral busbar is to be of 50% capacity. OUTGOING 6 Nos. 63 Amps 4PMCB 10 KA

2

-

-

... More
ELECTRICAL LIGHTING SUB-PANEL - Terrace INCOMING 100 Amps TP+N MCCB 35 KA (ics=icu) with adjustable thermal magnetic release having over current & short circuit & earth fault protection. 0-500 Volts digital volt meter shall be protected by 2 Amps TP MCB's. - 1 Set 0-100 Amps digital ammeter with 100/5 Amps 15 VA, CL 1 CTs . - 1 Set Phase indicating light shall be protected by 2 Amps SP MCB's. - 3 Set BUSBARS Electrolytic high conductivity aluminium three phase and neutral busbars rated at 200 amps having a maximum current density of 1.0 amp per sq.mm suitable to with stand symmetrical fault level of 35 M.V.A at 415 volts. The neutral busbar is to be of 100% capacity. OUTGOING 4 Nos. 40 Amps 4P MCB (10 KA)

1

-

-

... More
ELECTRICAL POWER SUB PANEL Terrace INCOMING 100 Amps TP+N MCCB 35 KA (ics=icu) with adjustable thermal magnetic release having over current & short circuit & earth fault protection. 0-500 Volts digital volt meter shall be protected by 2 Amps TP MCB's. - 1 Set 0-100 Amps digital ammeter with 100/5 Amps 15 VA, CL 1 CTs . - 1 Set Phase indicating light shall be protected by 2 Amps SP MCB's. - 3 Set BUSBARS Electrolytic high conductivity aluminium three phase and neutral busbars rated at 200 amps having a maximum current density of 1.0 amp per sq.mm suitable to with stand symmetrical fault level of 35 M.V.A at 415 volts. The neutral busbar is to be of 50% capacity. OUTGOING 4 Nos. 63 Amps 4PMCB 10 KA

1

-

-

... More
LIFT PANELS INCOMING:- 1 No. 250 amp TP+N MCCB 35 KA (ics=icu) with adjustable thermal magnetic release having over current & short circuit & earth fault protection. 0-500 Volts digital volt meter shall be protected by 2 Amps TP MCB's. - 1 Set 0-250 Amps digital ammeter with 150/5 Amps 15 VA, CL 1 CTs . - 1 Set Phase indicating light shall be protected by 2 Amps SP MCB's. - 3 Set BUS BARS Electrolytic high conductivity aluminium three phase and neutral busbars rated at 200 amps having a maximum current density of 1.0 amp per sq.mm suitable to with stand symmetrical fault level of 35 M.V.A at 415 volts. The neutral busbar is to be of 100% capacity. OUTGOINGS 10 Nos. 63 amp TP+N MCCB 35 KA (ics=icu) with adjustable thermal magnetic release having over current & short circuit & earth fault protection. 2 No.63 amp FP MCB of 10 kA.

1

-

-

... More
AC PANEL INCOMING:- 1 No. 400 amp TP+N MCCB 35 KA (ics=icu) with adjustable thermal magnetic release having over current & short circuit & earth fault protection. 0-500 Volts digital volt meter shall be protected by 2 Amps TP MCB's. - 1 Set 0-400 Amps digital ammeter with 400/5 Amps 15 VA, CL 1 CTs . - 1 Set Phase indicating light shall be protected by 2 Amps SP MCB's. - 3 Set BUS BARS Electrolytic high conductivity aluminium three phase and neutral busbars rated at 500 amps having a maximum current density of 1.0 amp per sq.mm suitable to with stand symmetrical fault level of 35 M.V.A. at 415 volts. The neutral busbar is to be of 100% capacity. OUTGOINGS 15 Nos. 63 amp TP+N MCCB 35 KA (ics=icu) with adjustable thermal magnetic release having over current & short circuit & earth fault protection.

1

-

-

... More
AC PANEL FOR Auditorium INCOMING:- 1 No. 200 amp TP+N MCCB 35 KA (ics=icu) with adjustable thermal magnetic release having over current & short circuit & earth fault protection. 0-500 Volts digital volt meter shall be protected by 2 Amps TP MCB's. - 1 Set 0-200 Amps digital ammeter with 200/5 Amps 15 VA, CL 1 CTs . - 1 Set Phase indicating light shall be protected by 2 Amps SP MCB's. - 3 Set BUS BARS Electrolytic high conductivity aluminium three phase and neutral busbars rated at 300 amps having a maximum current density of 1.0 amp per sq.mm suitable to with stand symmetrical fault level of 35 M.V.A at 415 volts. The neutral busbar is to be of 50% capacity. OUTGOINGS 6 Nos. 63 amp TP+N MCCB 35 KA (ics=icu) with adjustable thermal magnetic release having over current & short circuit & earth fault protection.

1

-

-

... More
MAIN UPS PANEL INCOMING:- 1 No. 125 amp FP MCCB 35 KA 0-500 Volts digital volt meter shall be protected by 2 Amps TP MCB's. - 1 Set 0-150 Amps digital ammeter with 150/5 Amps 15 VA, CL 1 CTs . - 1 Set Phase indicating light shall be protected by 2 Amps SP MCB's. - 3 Set BUS BARS Electrolytic high conductivity aluminium three phase and neutral busbars rated at 200 amps having a maximum current density of 1.0 amp per sq.mm suitable to with stand symmetrical fault level of 35 M.V.A at 415 volts. The neutral busbar is to be of 100% capacity. OUTGOINGS 2 Nos. 63 Amp. FP MCCB - 35 KA 4 Nos. 100 Amp FP MCCB 35 kA

1

-

-

... More
VENTILATION PANEL -Basement INCOMING:- 1 No. 100 amp TP+N MCCB 35 KA (ics=icu) with adjustable thermal magnetic release having over current & short circuit & earth fault protection. 0-500 Volts digital volt meter shall be protected by 2 Amps TP MCB's. - 1 Set 0-100 Amps digital ammeter with 100/5 Amps 15 VA, CL 1 CTs . - 1 Set Phase indicating light shall be protected by 2 Amps SP MCB's. - 3 Set BUS BARS Electrolytic high conductivity aluminium three phase and neutral busbars rated at 200 amps having a maximum current density of 1.0 amp per sq.mm suitable to with stand symmetrical fault level of 35 M.V.A at 415 volts. The neutral busbar is to be of 100% capacity. OUTGOINGS 8 Nos. 40 amp FP MCB 10 KA.

2

-

-

... More
EXTERNAL LIGHTING PANEL Location :- Ground Floor Supply, installation, testing & commissioning of External Lighting Panel, cubicle type, made out of 2 mm thick CRCA sheet, totally enclosed, IP-42, free standing, floor/Wall mounting, dust and vermin proof, indoor, compartmentalised, suitable for operation on 3 phase and neutral, 415 V, 50Hz AC system with busbars, including internal wiring with suitable size wires / cable, interconnection, duly powder coated painting etc. including supply & installation of following switchgears, metering instruments and accessories as per specifications. INCOMING 125 Amps TP+N MCCB 35 KA (ics=icu) with adjustable thermal magnetic release having over current & short circuit & earth fault protection. 0-500 Volts digital volt meter shall be protected by 2 Amps TP MCB's. - 1 Set 0-150 Amps digital ammeter and 150/5 Amps 15 VA, CL 1 CTs . - 1 Set Phase indicating light shall be protected by 2 Amps SP MCB's. - 3 Set BUSBARS Electrolytic high conductivity aluminium three phase and neutral busbars rated at 200 amps having a maximum current density of 1.0 amp per sq.mm suitable to with stand symmetrical fault level of 35 M.V.A at 415 volts. The neutral busbar is to be of 100% capacity. OUTGOING Six (6) nos. 63 amps TP+N MCCB 35 KA (ics=icu) with adjustable thermal magnetic release having over current & short circuit & earth fault protection.

2

-

-

... More
SUPPLY OF LT CABLE Supply of following size of 1.1 KV grade multicore aluminium conductor XLPE insulated and PVC sheathed armoured cable as per IS : 7098:1988 with upto date amendments. 3.5 core, 50 Sq.mm.

1030

-

-

... More
3.5 core, 70 Sq.mm.

360

-

-

... More
3.5 core, 120 Sq.mm.

10

-

-

... More
3.5 core, 185 Sq.mm.

550

-

-

... More
3.5 core, 240 Sq.mm.

200

-

-

... More
3.5 core, 300 Sq.mm.

930

-

-

... More
1 core, 630 Sq.mm.

1850

-

-

... More
3 core, 6 Sq.mm.

285

-

-

... More
4 core, 6 Sq.mm.

1712

-

-

... More
4 core, 10 Sq.mm.

3792

-

-

... More
4 core, 16 Sq.mm.

1319

-

-

... More
4 core, 25 Sq.mm.

865

-

-

... More
4 core, 50 Sq.mm.

130

-

-

... More
4 core, 70 Sq.mm.

80

-

-

... More
3 core, 6 Sq.mm.

285

-

-

... More
Control Cables Supply, Receiving, storing, laying, making proper connections, testing and commissioning of the following sizes of 1.1 KV grade PVC insulated copper conductor, armoured,multi stranded control cable in the existing pipes / channels / trays etc. complete as required and as per specifications. 2 core x 1.5 sq. mm cable

300

-

-

... More
4 core x 2.5 sq. mm cable

300

-

-

... More
6 core x 2.5 sq. mm cable

300

-

-

... More
10 core x 2.5 sq. mm cable

400

-

-

... More
12 core x 2.5 sq. mm cable

400

-

-

... More
24 core x 2.5 sq. mm cable

400

-

-

... More
LT CABLE LAYING AND TERMINATIONS Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Upto 35 sq. mm

3500

-

-

... More
Above 35 sq. mm and upto 95 sq. mm

500

-

-

... More
Above 185 sq. mm and upto 400 sq. mm

200

-

-

... More
Above 400 sq. mm and upto 630 sq. mm

1500

-

-

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Upto 35 sq. mm

130

-

-

... More
Above 35 sq. mm and upto 95 sq. mm

50

-

-

... More
Above 185 sq. mm and upto 400 sq. mm

130

-

-

... More
Above 400 sq. mm and upto 630 sq. mm

150

-

-

... More
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. Upto 35 sq. mm (clamped with 1mm thick saddle)

1713

-

-

... More
Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)

500

-

-

... More
Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)

5

-

-

... More
Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp)

200

-

-

... More
Above 400 sq. mm and upto 630 sq. mm (clamped with 50x3mm MS flat clamp)

200

-

-

... More
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. Upto 35 sq. mm (clamped with 1mm thick saddle)

2630

-

-

... More
Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)

550

-

-

... More
Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)

5

-

-

... More
Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp)

1150

-

-

... More
S/M LV/MV Cable End Termination: Supplying and making indoor end termination with double brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3 core, 6 Sq.mm.

12

-

-

... More
4 core, 6 Sq.mm.

120

-

-

... More
4 core, 10 Sq.mm. (25 mm)

304

-

-

... More
4 core, 16 Sq.mm. (28 mm)

92

-

-

... More
4 core, 25 Sq.mm. (28 mm)

10

-

-

... More
3.5 core, 50 Sq.mm. (35 mm)

30

-

-

... More
4 core, 50 Sq.mm. (35 mm)

4

-

-

... More
3.5 core, 70 Sq.mm. (38 mm)

14

-

-

... More
4 core, 70 Sq.mm.

2

-

-

... More
3.5 core, 120 Sq.mm. (45 mm)

2

-

-

... More
3.5 core, 185 Sq.mm. (57 mm)

6

-

-

... More
3.5 core, 240 Sq.mm. (62 mm)

2

-

-

... More
3.5 core, 300 Sq.mm. (70 mm)

20

-

-

... More
1 core, 630 Sq.mm.

44

-

-

... More
Control Cables Termination Supply and making end terminal joints for the following sizes of 1.1 KV PVC insulated Copper conductor cables, including providing tinned copper terminal lugs, double compression brass cable glands, insulation tape, effecting terminal connections to the equipment complete as required. 2 core x 1.5 sq. mm

6

-

-

... More
4 core x 2.5 sq. mm

6

-

-

... More
6 core x 2.5 sq. mm

6

-

-

... More
10 core x 2.5 sq. mm

12

-

-

... More
12 core x 2.5 sq. mm

12

-

-

... More
24 core x 2.5 sq. mm

12

-

-

... More
Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required.

30

-

-

... More
MS CABLE TRAYS AND PIPES Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 150 mm width X 50 mm depth X 1.6 mm thickness

500

-

-

... More
300 mm width X 50 mm depth X 1.6 mm thickness

1200

-

-

... More
600 mm width X 75 mm depth X 2.0 mm thickness

200

-

-

... More
750 mm width X 75 mm depth X 2.0 mm thickness

100

-

-

... More
900 mm width X 75 mm depth X 2.0 mm thickness

59

-

-

... More
Supplying and installing following size of perforated pre-painted M.S. cable trays bends with perforation not more than 17.5%,,joined with connectors, suspended from the ceiling with M.S.suspenders including bolts & nuts, painting suspenders etc as required. 150 mm width X 50 mm depth X 1.6 mm thickness

120

-

-

... More
300 mm width X 50 mm depth X 1.6 mm thickness

20

-

-

... More
600 mm width X 75 mm depth X 2.0 mm thickness

20

-

-

... More
750 mm width X 75 mm depth X 2.0 mm thickness

20

-

-

... More
900 mm width X 75 mm depth X 2.0 mm thickness

10

-

-

... More
Supplying and installing following size of perforated pre-painted M.S. cable trays reducers with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S.suspenders including bolts & nuts, painting suspenders etc as required. 150 mm width X 50 mm depth X 1.6 mm thickness

160

-

-

... More
300 mm width X 50 mm depth X 1.6 mm thickness

30

-

-

... More
600 mm width X 75 mm depth X 2.0 mm thickness

20

-

-

... More
750 mm width X 75 mm depth X 2.0 mm thickness

10

-

-

... More
Supplying and installing following size of perforated pre-painted M.S. cable trays Tee’s with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S.suspenders including bolts & nuts, painting suspenders etc as required. 150 mm width X 50 mm depth X 1.6 mm thickness

60

-

-

... More
300 mm width X 50 mm depth X 1.6 mm thickness

10

-

-

... More
600 mm width X 75 mm depth X 2.0 mm thickness

10

-

-

... More
750 mm width X 75 mm depth X 2.0 mm thickness

10

-

-

... More
900 mm width X 75 mm depth X 2.0 mm thickness

5

-

-

... More
Supplying and installing following size of perforated pre-painted M.S. cable trays cross members with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 150 mm width X 50 mm depth X 1.6 mm thickness

20

-

-

... More
300 mm width X 50 mm depth X 1.6 mm thickness

5

-

-

... More
450 mm width X 50 mm depth X 2.0 mm thickness

5

-

-

... More
600 mm width X 75 mm depth X 2.0 mm thickness

5

-

-

... More
750 mm width X 75 mm depth X 2.0 mm thickness

5

-

-

... More
900 mm width X 75 mm depth X 2.0 mm thickness

4

-

-

... More
Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required. 250 mm inner dia

300

-

-

... More
300 mm inner dia

30

-

-

... More
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.

50

-

-

... More
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. (but without charcoal/ coke and salt ) as required.

30

-

-

... More
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.

1000

-

-

... More
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.

200

-

-

... More
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.

300

-

-

... More
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)

300

-

-

... More
Providing and fixing 75 mm x 6 mm GI strip on surface or in recess for connections etc. as required.

250

-

-

... More
Providing and fixing 75 mm x 6 mm GI strip in 100 mm dia. G.I. Pipe from earth electrode as required.

80

-

-

... More
Supplying and fixing 75 mm x 6mm GI strip at 0.50m below ground level as strip earth electrode, including soldering etc. as required.

80

-

-

... More
Providing and fixing 75 mm x 3 mm Cu strip on surface or in recess for connections etc. as required.

80

-

-

... More
Providing and fixing 75 mm x 3 mm Cu strip in 100 mm dia. G.I. Pipe from earth electrode as required.

50

-

-

... More
Supplying and fixing 75 mm x 3 mm Cu strip at 0.50m below ground level as strip earth electrode, including soldering etc. as required.

30

-

-

... More
Providing and fixing 50 mm x 6mm GI strip on surface or in recess for connections etc. as required.

40

-

-

... More
Providing and fixing 50 mm x 6 mm GI strip in 75 mm dia. G.I. Pipe from earth electrode as required.

20

-

-

... More
Supplying and fixing 50 mm x 6 mm GI strip at 0.50m below ground level as strip earth electrode, including soldering etc. as required.

40

-

-

... More
Providing and fixing 25 mm x 3 mm Cu strip on surface or in recess for connections etc. as required.

200

-

-

... More
Providing and fixing 25 mm x 3 mm Cu strip in 40 mm dia. G.I. Pipe from earth electrode as required.

70

-

-

... More
Supplying and fixing 25 mm x 3 mm Cu strip at 0.50m below ground level as strip earth electrode, including soldering etc. as required.

50

-

-

... More
SAFETY EQUIPMENTS Supplying and erection of the following equipment at suitable place in the sub-station building as required. M.S. Buckets (6 Nos.) of 15/20 litres capacity painted with Red Oxide paint & lettered as ‘Fire’ with White and mounted on free standing stand, as required including filling with dry sand.

2

-

-

... More
First Aid Box as approved by St. John Ambulance Brigade / Indian Red Cross society conforming to IS : 2217 - 1963.

2

-

-

... More
Shock Treatment Chart duly mounted on a wooden frame with glass on, as required in 2 languages (Hindi & English)

2

-

-

... More
Rubber Mat 914.4 mm. wide and 6 mm. thick to withstand 1.1 KV dielectric strength.

15

-

-

... More
Rubber Gloves of 1.1 KV grade as per IS 4770-68.

2

-

-

... More
Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.

5

-

-

... More
Providing and fixing H.T. danger notice plate of 250 mm X 200 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.

2

-

-

... More
Supply and fixing of Carbon Di-oxide Fire Extinguishers of 4.5 Kg. each mounted on wall hooks as per IS 2878-1976.

3

-

-

... More
Supply and fixing of Dry Chemical Fire Extinguishers 5 Kg. as per IS: 2171-1976 mounted on wall hooks.

3

-

-

... More
Providing and fixing Single Line Diagram duly mounted on a wooden frame with glass on, as required.

2

-

-

... More
EXTERNAL LIGHT FIXTURES: Supplying, installation, testing and commissioning of following light fixtures complete with choke, lamp and mounting arrangement, other accessories etc. complete as required for Pole Lights fixtures, aesthethic outdoor light fixture. Supply & fixing of 32mm x 2 mtrs. GI Pipe (medium class) for Gate light fitting complete as required or equivalent.

10

-

-

... More
Supplying, installation, testing & commissioning of Gate Light fitting with 1 x 70 watt fitting including 50mm dia GI pipe-0.5 mtrs. Bajaj : BGP151 LED2000/WW PSU 220-240V 7043 or equivalent.

10

-

-

... More
Supplying, installation, testing & commissioning of Bollard Light fitting with 1 x 18 watt fitting Bajaj : BCP150 LED150/WW PSU 220-240V 7043 or equivalent.

120

-

-

... More
Supply and fixing of floor mounting, totally enclosed, compartmentalized, cubical, dust, vermin proof and outdoor type Feeder Piller fabricated out of 2 mm thick cold rolled carbon anealed, sheet steel, internally strengthened with angle iron frame work with following incoming and outgoing feeders (fabricated out of 2 mm CRCA Sheet steel) including supplying and mounting including making connections/inter-connections with lugs / glands crimping tools, testing and commissioning of following items inside the panel :- INCOMER : 63 A TP+N MCCB (25 KA) with On / Off indications in the front (ISI marked) LED Type Phase indicating - (R,Y& B) Lamps provided with 2A SP MCBs for protection having lens and lamp openable from the top.-3 nos. OUTGOING: SP MCB-10/32Amps-C Series 10 KA-6 nos. 4P MCB-10-20/32Amps-C Series 10 KA-6 nos. CONTROL: 4 Pole Contactor with a thermal rating of 63A - 1 no. Time Switch with 1 channel Daily cycle, suitable for operation on 230 Volt, Single phase, 50 Hz, AC Supply - 3 Nos. Auto-Manual Selector switch - 3 Nos. On/ Off Push Buttons-3 Nos

3

-

-

... More
SUB HEAD-26 DIESEL GENERATOR SET DIESEL GENERATOR SET :- RADIATOR COOLED DG SET Supplying, installation, testing & commissioning of radiator cooled type diesel generating set comprising of multi- cylinder diesel oil engine with radiator, fly wheel, exhaust piping upto silencer, residential type silencer, electric starting equipments, batteries, battery charger, directly coupled to an alternator of suitable capacity at 0.8 P.F. 3 phase, 4 wire 50 Hz 415 volts, A.C supply complete with brass plate anti-vibration mountings foundations for installation of D.G. set, terminating arrangement for outgoing cables, control panel, controlling MCCB etc, complete as required as per specifications, Drawings and specified ambient conditions. The D.G. Sets shall be canopy type as per relevant IS and present bye-laws. 500 KVA D.G. set with canopy The Foundation shall be in the scope of the DG set supplier. The DG set is to be installed on the ground floor. The supervision, testing and commissioning of the AMF logic in the LT Panel, shall be in the scope of the LT Panel supplier. The DG set should be supplied with cable end box to terminate suitable size of cable on alternator complete as required. Fuel Oil required for Testing the DG set as per IS shall be supplied by the Client. The canopy should be designed in such a way that the Noise level is not more than 75 db level at a distance of 1 meter away from the DG set as per Indian standards. Isolation Panel with breaker for each DG Set shall be in the scope of DG Set Suppliers. The Control Panel shall have the following: 0-500 V voltmeter with 6-position selector switch with protective fuses (for alternator potential) of size 96 mm x 96 mm. Ammeter with 4-position selector switch (for alternator load) of size 96 mm x 96 mm. Frequency meter size 96 mm x 96 mm. Power Factor Meter, 0.5 Lag, unity 0.5 lead, 3 phase 4 wire. KWH meter, 3 phase, 4 wire. KW meter, 3 phase, 4 wire. Voltmeter and supervisory lamp for 24V DC supply supervision. Emergency stop push button for alternator. Indicating lamps for alternator supply Red, Yellow, Blue with ballast resistance and protective fuses. Running time meter to indicate number of hours of operation. Counter to indicate number of attempts made to start the set with reset facility. Auto/Manual/Test Selector Switch. Auto/manual selector switch. Battery charger may be incorporated in this panel. One switch fuse unit for incoming AC supply for battery charging (switch fuse rating to suit). Annunciator Panel shall be as per the specifications The contractor shall submit back-pressure calculations in suport of exhaust pipe size for each DG Set.

2

-

-

... More
Supplying, installation, testing and commissioning of exhaust piping / chimney up to top level made out of suitable dia M.S. piping complete with bends, duly painted with primer and insulated with 100mm thick layer of LRB rock wool having 100 Kg/m³ density, white wool. Finishing of the insulation shall be with chicken wire mesh and 26g. Aluminium sheet cladding all around exhaust pite joints will be overlapped to 75mm width and provided with self tapping screws complete with structural support arrangement as required. 250 mm dia pipe for 500 KVA D.G. Sets.

50

-

-

... More
Supply of heavy duty Hand cranking oil pump with 3 mtr. Long flexible oil hose.

1

-

-

... More
Supplying, installation, testing and commissioning of 990 Ltrs. Day Oil fuel tank of under mentioned capacities made out of 5 mm thick M.S. sheet with float valve and low level alarm arrangement including fuel oil piping up to the set valves etc. complete as required.

2

-

-

... More
Supplying, installation, testing and commissioning of Suitable rating Fuel Oil pump including foundations, piping, valves, indications, safety devices etc. complete as required. (Crompton / GE / Kirloskar make) A separate Day oil tank shall be provided instead of Inbuilt fuel tank. The Day oil tank shall be suitably treated with oil resistant paint / anti corrosive treatment on inside & outside surface respectively. Tanks shall be provided with Low/ High Level Sensor and alarm indication. The MS Piping shall be “Class-C” and shall be treated with anti corrosive treatment. The fuel oil pump shall be installed on the Ground Floor complete with foundations and will be common for both the DG sets. The Fuel transfer Pump shall be as per Relevant IS for this type of application.

1

-

-

... More
STEEL STRUCTURE Supply, fabrication, cutting, welding, threading, drilling and installation etc. of exhaust pipe support structure as per requirements at site in multitier formation including painting with 2 coats of red oxide primer and 2 coats of approved enamel paint / aluminium paint complete as required.

20000

-

-

... More
Supply, installation, testing and commissioning of 10 KVA TRUE ONLINE double conversion VFI Technology UPS (High frequency PWM using IGBT technology), Parallel redundant, Single Phase AC input & Single Phase AC output, 30 min backup, fully microprocessor based UPS system suitable for 220 VAC, +10% -10%, 50 Hz supply, variation +/- 1%, Power Factor-0.8. Battery consisting of following:- Galvanic Isolation Transformer at Inverter Input with Delta star connection to separate Input and Output Neutral. Input range should be 320 VAC – 480 VAC. IGBT Rectifier with each UPS. Fully microprocessor Digital Signal Processing (DSP) based with diagnostics capability . Maintenance by-pass module. Microprocessor based LCD display indication for various parameter's display & LED indication for alarm for major status parameters and provisions for remote indications. The system shall be as per detailed specifications and shall be complete with all connections / inter-connections & provisions for static bypass etc. with required accessories as required. Suitable size and Nos. of Valve Regulated Lead Acid (VRLA) Sealed Maintenance Free batteries in suitable numbers and Ampere hour capacity suitable for 10 KVA UPS system for providing 30 minutes back up time at full load, with interconnecting cables, mounting racks / stands for stacking the batteries, along with connections, interconnections and standard accessories etc. complete as required. (12V Cells, 5 year Design life). 10 KVA UPS

2

-

-

... More
Supplying, installing, testing and commissioning of multistage centifugal pumpset with mechanical seal, CI casing & impeller, Carbon steel shaft connected to a TEFC induction motor of suitable rating, 415+ 10% volts, three phase, 50 Hz A.C. supply, complete with vibration isolators, base plate, foundation, including providing pump controller & level switches to start and stop the pump automatically at predecided levels of the water in the tank with provision of protection for dry run including wiring etc all panels should be MCB isolation DOL/ SD Starter + Push Button on/off indicating lamp, single phase prevantor as required for each set of pump. complete as required. Domestic & Flushing Water Transfer Pump Capacity - 650 LPM Head - 60 mtr HP -20 (2 No. of pump in 1 Set (1W+1S)

2

-

-

... More
Supplying, installing, testing and commissioning of multistage centifugal pumpset with mechanical seal, CI casing & impeller, Carbon steel shaft connected to a TEFC induction motor of suitable rating, 415+ 10% volts, three phase, 50 Hz A.C. supply, complete with vibration isolators, base plate, foundation, including providing pump controller & level switches to start and stop the pump automatically at predecided levels of the water in the tank with provision of protection for dry run including wiring etc all panels should be MCB isolation DOL/ SD Starter + Push Button on/off indicating lamp, single phase prevantor as required for each set of pump. complete as required. Soft Water Transfer Pump Capacity - 250 LPM Head - 25 mtr HP - 4 (2 No. of pump in 1 Set (1W+1S)

1

-

-

... More
Supplying, Installation, Testing and commissioning of submersible type Sump pump sets of CI casing & impeller, SS shaft, with inbuilt water level sensors for operating the pumps automatically, starter with push button arrangement and all accessories suitable for operation on 220+10% V, single phase/ three phase, 50 Hz. AC supply etc. all panels should be MCB isolation DOL/ SD Starter + Push Button on/off indicating lamp, single phase prevantor as required for each set of pump as required. Capacity - 150 LPM Head - 15 Mtr HP - 1.5 (2 No. of pump in 1 Set (1W+1S)

4

-

-

... More
TUBEWELL PUMP Supplying, Installation, Testing and commissioning of submersible pump and electrical panel suitable for 8" dia casing of bore with SS impeller, high tensile SS shaft, copper wound squirrel cage directely coupled wet type induction motor 15 H.P. (minimum), 2900 rpm, suitable for operating on 415+10% V, 50 Hz,3 phase A.C. supply, conforming to ISS: 8034-1976, capacity 15 m3 per hour, at 150 mtr head, water lubricated bearings and provided with pivoted segment type thrust bearings to withstand non-vertical lead with minimum wear and tear and duly fitted with device to take up the expansion of water with heating of motor. The contractor to obtain approval for model and make of pumpset & suitable Electrical panel after having yield report of fully developed tube well and submit actual bore strata chart. including supplying laying and fixing 3 mtr water proof PVC insulated flat submersible cable 1x4Cx6 sqmm with end termination with its accessories. complete in all respect as required.

1

-

-

... More
PLUMBING PLANT ROOM PANEL Location: Plumbing Plant Room INCOMINGS One (1) Nos. 160 Amps TP+N MCCB 35 KA (Ics = Icu) with adjustable thermal magnetic release having overcurrent and short circuit & Earth Fault Protection. Three phase indicating lamp (LED type) with MCB. BUSBAR Electrolytic high conductivity aluminium three phase and neutral busbars rated at 200 amps having a maximum current density of 1.0 amp per sq.mm suitable to with stand symmetrical fault level of 25 M.V.A at 415 volts. The neutral busbar is to be of 100% capacity. OUTGOING UNITS For 3 Phase, 12 KW Domestic/Flushing Transfer Pump - 2 Sets (02 No. of pump in 1 Set) 63 A TP MPCB with inbuilt relay, Star delta starter and contactor, start / stop push buttons, phase indication lights with protection MCB, on / off / trip indication lights with protection MCB, single phase preventer with auto / manual mode selector switch & current sensing phase failure and UV relay,OV relay. Controls & interlocking accessories as required For 3 Phase, 3 KW Filter Feed Pump - 1 Sets (02 No. of pump in 1 Set) 16 A TP MPCB with inbuilt relay, DOL starter and contactor, start / stop push buttons, phase indication lights with protection MCB, on / off / trip indication lights with protection MCB, single phase preventer with auto / manual mode selector switch & current sensing phase failure and UV relay,OV relay. Controls & interlocking accessories as required For 1 Phase, Max. 1 KW Drainage Sump Pump - 1 Sets (02 No. of pump in 1 Set) 16 A TP MPCB with inbuilt relay, DOL starter and contactor, start / stop push buttons, phase indication lights with protection MCB, on / off / trip indication lights with protection MCB, single phase preventer with auto / manual mode selector switch & current sensing phase failure and UV relay,OV relay. Controls & interlocking accessories as required For 3 Phase, 4 KW Soft Water Transfer - 1 Sets (02 No. of pump in 1 Set) 16 A TP MPCB with inbuilt relay, DOL starter and contactor, start / stop push buttons, phase indication lights with protection MCB, on / off / trip indication lights with protection MCB, single phase preventer with auto / manual mode selector switch & current sensing phase failure and UV relay,OV relay. Controls & interlocking accessories as required For 3 Phase, Max 12 KW Submersible tubewell pump in site or plant room - 1 No of pump. 63 A TP MPCB with inbuilt relay, star delta starter and contactor, start / stop push buttons, phase indication lights with protection MCB, on / off / trip indication lights with protection MCB, single phase preventer with auto / manual mode selector switch & current sensing phase failure and UV relay,OV relay. Controls & interlocking accessories as required Three Number 63A TP MPCB Spare Three Number 40 A TP MPCB Spare Controls & interlocking accessories as required

1

-

-

... More
Supplying of following sizes PVC insulated and PVC sheathed Power cable of 1.1 KV grade armoured LT cable as required confirming to IS:1554/IS-7098 (Part-I) 1988 4C x 6 sq. mm.

25

-

-

... More
4C x 10 sq. mm.

70

-

-

... More
4C x 16 sq. mm.

320

-

-

... More
3.5C x 120 sq. mm.

250

-

-

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Upto 35 sq. mm

60

-

-

... More
Above 95 sq. mm and upto 185 sq. mm

80

-

-

... More
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. Upto 35 sq. mm (clamped with 1mm thick saddle)

100

-

-

... More
Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)

75

-

-

... More
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. Upto 35 sq. mm (clamped with 1mm thick saddle)

50

-

-

... More
Above 95 sq. mm and upto 185 sq. mm (clamped with 40x3mm MS flat clamp)

30

-

-

... More
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Upto 35 sq. mm

120

-

-

... More
Above 95 sq. mm and upto 185 sq. mm

150

-

-

... More
Supplying, laying & termination control wiring with multicore copper stranded conductor of following sizes PVC insulated, PVC sheathed armoured under ground cable between various sensors and system controller/starter etc. in pump house and out side on surface/existing cable tray complete with connections at both end with glands etc. as required. 8C x 2.5 sq. mm.

35

-

-

... More
6C x 2.5 sq. mm

35

-

-

... More
4C x 2.5 sq. mm

30

-

-

... More
2C x 2.5 sq. mm

100

-

-

... More
Supplying and making indoor end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4C x 6 sq. mm.

4

-

-

... More
4C x 10 sq. mm.

4

-

-

... More
4C x 16 sq. mm.

12

-

-

... More
3.5C x 120 sq. mm.

2

-

-

... More
HOT WATER GENERATOR INCLUDING SOLAR SYSTEM Supply, Installation, testing & commissioning of fully automatic, horizontal, coil type, hot water Generator, capable of generating 100000 kcal / hr. when fire on HSD. The hot water generating shall be complete with Heat exchanger, calorifier, expansion tank, Primary Circulation pump, safety valve, strainers, temperature controllers, pressure/temp gauges and secondary water thermostat, monoblock burner with on/off control dust protected, prewired electrical panel including water piping connecting the unit & pump etc. The scope shall include the following: All inter-connecting wiring/cabling from burner, hot water circulation pump, fuel pump, control cabling etc. up to electrical panel. Field mounted temperture gauge, 6" dial/0-600 c./Bottor Entry/1/2" BSP with fitting at the outlet of each hot water generator. The hot water generator shall be suitable for AC 3 phase, 415+_6%; 50Hz+-3%,4 wire system. Complete as required. 2 set of hot water generator(1 working+1standby)

2

-

-

... More
CS ball valve, flanged end as per ANSI B 16.5 Class 150 RF complete with matching flanges, Gasket, hardware etc for installation at outlet of Hot water generator. 40 NB

10

-

-

... More
CS NRV, Swing check, flanged end as per ANSI B 16.5 class 150RF, complete with matching flanges, gasket, hardware etc for installation at outlet of each Hot water generator. 40 NB

8

-

-

... More
CS Strainer, flanged end as per ANSI B 16.5 class 150RF, 40 mesh, complete with matching flanges, gasket, hardware etc for installation at suction of each circulation pump. 25 NB

4

-

-

... More
FUEL CIRCUIT (HSD) MS Fuel oil tank, 990 ltrs, fabricated out of 5 mm thick MS sheet, complete with nozzles for inlet, outlet, drain, overflow, manhole, magnetic level gauge etc. All nozzles shall be fabricated from MS ERW C Class pipe. All flanges shall be confirming to ANSI B 16.5, 150# RF. The tank shall be provided with the following valves, fittings and instrumetns CS Ball Valve, flanged, ASA 150, 25 NB CS Ball Valve, flanged, ASA 150, 40 NB Magnetic Level Gauge with 3 nos Switches

1

-

-

... More
Fuel oil piping, fabricated from MS C Class ERW pipe as per IS 1239, complete with seamless schedule 40 bends, flanges, pre-cut gasket, hardware, supports etc. for connecting fuel oil tank to boiler. The scope includes bypass piping from burner and fuel pump, terminated into fuel feed line. 15 mm NB

25

-

-

... More
25 mm NB

10

-

-

... More
40 mm NB

10

-

-

... More
Bronze Ball Valve, flanged, ASA 150, 25 NB

4

-

-

... More
Bronze Strainer, flanged, 80 mesh, ASA 150, 25 NB

2

-

-

... More
Bronze NRV, flanged, 25 NB

4

-

-

... More
10 NB x 1 mtr long

6

-

-

... More
15 NB x 1 mtr long

6

-

-

... More
Supply, intallation, testing and commissioning of SS 304 Hot Water Mixing Tank of capacity 4000 litres, fabricated from 6 mm thick shell and 8 mm thick dish, complete with nozzles for inlet, outlet, drain, hydro-pneumatic, vent, manhole etc. All nozzles shall be fabricated from SS 304 Sch 40 ERW pipe. All flanges shall be conforming to ANSI B 16.5, 150 # RF. The tank must be suitable for working pressure of 6 Kg/cm2 and test pressure of 10 Kg/cm2. Tank shall be fabricated as per unfired pressure vessel code IS 2825 - 1969, IS226/IS2062. The hot water mixing tank must be provided with the requisite number of ASA 150 Flanged type CS Ball valves, CI Butterfly valves, PN16 Class CI Wafer Type NRV of PN 16 Class, Safety Relief Valve flanged type, Thermowells, Pressure Gauge 150 mm with syphon and isolation valve. The hot water mixing tank shall be externally insulated with 100 mm thick Glass wool having bulk density of 32 Kg/m3 and covered with 20 mm thick chicken wire mesh and cladded with 24 G Aluminium Sheet.

1

-

-

... More
Providing, fixing, testing & commissioing electrical driven inline pumping sets 2 nos. (1 working + 1 stand by) suitable for handling hot water upto a temperature of 800 C with all accessories. Pumps shall be with C.I. Base, S.S 304 impellers, mechanical seal, S.S. Shaft directly coupled to TEFC induction motor suitable for operation on 220 + 10% volts, 3 phase 50 Hz A.C. Supply complete set to be mounted on a common channel baseplate GM isolation cock and cement concrete foundation with plaster with dunlop cushy foot mountings with all accessories such as NRVs, valves, common suction and delivery header including all pipes, bellows on sucton and delivery side, timer & thermo statics controller & sensor complete including timer setting and temperature setting in all repsects Minimum Capacity - 35 LPM Minimum Head - 50 Mtr HP - As required (2 No. of pump in 1 Set (1W+1S)

1

-

-

... More
SOLAR WATER HEATING SYSTEM Supply, Installation, Testing & Commissioning of 2000 LPD FPC based Solar Water Heating System comprising of internal piping complete in all respects as per approved specifications with hot water storage tank with heat exchanger, electrical wiring, valves on inlet & outlet, Y strainer and all necessary valves, temperature gauge (0-120 deg. C), accessories, control and indication equipment fittings to produce hot water at 60 deg C. Details of each item mentioned below: (Design & Shop Drawings of the entire system to be approved) "(i) Solar FPC Type as details given below:- - type -Cu-Cu - Absorptivity 90 % - Emissivity 0.2 - Tranmissivity 0.85 - Fins 0.15 mm thick, width - 110 mm, length - 1900 mm - Vacuum Degree: 5x10-3 Pa - Heat loss coefficient (K value): 0.90 Watt/ M2 0C (ii) Solar hot water storage tank capacity of 2000 litre made up of SS-304L thickness 2 mm with 40 mm thick CFC free PUF insulation & 22 swg GI cladding (iii) M.S. channel Stand for Hot Water Storage Tank including all necessary foundations as per site. (iv) Inter-connected G.I. 'C' Class System piping of 15, 20, 25, 32 & 40 mm with GI fittings and insulated with 40 mm thick Glass wool / Rockwool insulation covered with chicken mesh and GI cladding. Piping should be inclusive of all accessories & fittings. - 1 Lot. a) Temperature Gauge - 1 No. b) Ball Valve size 25 NB - 2 Nos. c) NRV size 25 NB - 1 No. d) CI Y Strainer 25 NB - 1 No. Note:- Control Valves/ Mountings (Consisting of all ball valves, Non-Return Valves, Y Strainers, Pressure release Valves, Pressure Gauges, Temperature gauge, Air Release Valves and all other accessories required to complete the system) (v) Wire Mesh of 10 SWG fitted with M.S frame of 35x35x3 mm for proper support and fitted with the help of clamp to protect from Monkeys, Heavy storm etc. gap of wire mesh is 25x25 mm. (vi) Civil work for grouting of the system. - 1 Lot

1

-

-

... More
Supply, Installation, Testing & Commissioning of monobloc centifugal pumpset with mechanical seal, CI casing & impeller, Carbon steel shaft connected to a TEFC induction motor of suitable rating, 220+10% volts, three phase, 50 Hz A.C. supply, complete with vibration isolators, base plate, foundation, including providing timer,thermostatic controller & sensor complete including timer setting & provision of protection for dry run, wiring etc all panels should be MCB isolation DOL/ SD Starter + Push Button on/off indicating lamp, single phase prevantor as required for each set of pump. complete as required Solar Feed Pump Minimum Capacity - 10 LPM Minimum Head - 15 Mtr HP - As required 2 No. of pump in 1 Set (1W+1S)

1

-

-

... More
RECIRCULATION, SOLAR FEED & BOILER PUMP PANEL Location : Terrace level Providing and fixing dust and vermin proof cubical type motor control centre for the pumps mentioned hot water system. It is fabricated from 2 mm thick sheet with stove enamelled finish and comprising of: INCOMINGS One (1) Nos. 63 Amps TP+N MCCB 25 KA a) Three phase indicating lamp (LED type) with MCB. b) Voltmeter (0-500 Volts) with selector switch. BUSBARProviding and fixing dust and vermin proof cubical type motor control centre for the pumps mentioned hot water system. It is fabricated from 2 mm thick sheet with stove enamelled finish and comprising of: INCOMINGS One (1) Nos. 63 Amps TP+N MCCB 25 KA a) Three phase indicating lamp (LED type) with MCB. b) Voltmeter (0-500 Volts) with selector switch. BUSBAR Electrolytic high conductivity aluminium three phase and neutral busbars rated at 100 amps having a maximum current density of 1.0 amp per sq.mm suitable to with stand symmetrical fault level of 25 M.V.A at 415 volts. The neutral busbar is to be of 100% capacity. OUTGOING UNITS For 3 Phase, 1.5 KW Solar Feed Pump + circulation pump + monoblock burner - 3 Set (02 No. of pump in 1 Set) 16 A TP MPCB with inbuilt relay, DOL starter and contactor, start / stop push buttons, phase indication lights with protection MCB, on / off / trip indication lights with protection MCB, single phase preventer with auto / manual mode selector switch & current sensing phase failure and UV relay,OV relay. Controls & interlocking accessories as required Three Number 40 A TP MPCB Spare Three Number 63 A TP MPCB Spare Controls & interlocking accessories as required Colour coded internal wiring from incoming Main to bus bar switch gear, starters, meters indicating lamps complete in all respect. (The rating of all switch gear must match the HP of all pumps quoted). Electrolytic high conductivity aluminium three phase and neutral busbars rated at 100 amps having a maximum current density of 1.0 amp per sq.mm suitable to with stand symmetrical fault level of 25 M.V.A at 415 volts. The neutral busbar is to be of 100% capacity. OUTGOING UNITS For 3 Phase, 1.5 KW Solar Feed Pump + circulation pump + monoblock burner - 3 Set (02 No. of pump in 1 Set) 16 A TP MPCB with inbuilt relay, DOL starter and contactor, start / stop push buttons, phase indication lights with protection MCB, on / off / trip indication lights with protection MCB, single phase preventer with auto / manual mode selector switch & current sensing phase failure and UV relay,OV relay. Controls & interlocking accessories as required Three Number 40 A TP MPCB Spare Three Number 63 A TP MPCB Spare Controls & interlocking accessories as required Colour coded internal wiring from incoming Main to bus bar switch gear, starters, meters indicating lamps complete in all respect. (The rating of all switch gear must match the HP of all pumps quoted).

1

-

-

... More
Providing, fixing, testing & commissioning of skid mounted fully automatic Reverse Osmosis System of output capacity 600 litres / hour designed at a minimum Flux at inlet and necessary of minimum 85% recovery, complete as required with the following items: Purpose: RO plant for purified water supply for drinking Filter feed pump 2 No. (1w+1s) @40 mtr ,440 ±10%V,three phase,50 HZ,2900 RPM, MOC-SS 2 No. Micron filter to remove upto 0.5 micron Antiscalant Dosing & lime dosing System ,pump 0-6 LPH with level sensors ,dosing tanks 2 No.Cartridge Filter Vertical multistage High pressure pump (1w+1s)@90 mtr,440 ±10% V,three phase,50 HZ,2900 RPM, MOC-SS 1 set R.O skid of MS base frame 4 No Membranes spiral wounded,recovery per memberane 15%,salt rejection:98-99%. 2 No RO Pressure Tubes Membrane washing system with washing pump flushing time 15 minute 1 No RO skid 1 No pH correction system Necessary instruments 1 LOT Interconnecting pipe with necessary valve work1 LOT i) uPVC pipe 16 bar (upto HP Pump),NRV.PRV,ball valve etc.complete. ii) SS (HP Pump to Membrane) 1 LOT 6 No Pressure gauges 3 No Rotameter 1 No PPLC cum instrument panel 1 No Conductivity Indicator Level sensors (Antiscalent Tank) - H/LLevel sensors (Permeate Tank) - H/L 1 No Solenoid Valve (Inlet) to R.O. tank 1 No. Solenoid Valve (Reject) 2 no flow meterto measure online flow of water\ 1 No.TDS meter to measure online flow of water 2 no flow meter to measure online TDS of water 1 no Low presure switch to protect RO pump from dry running. 1 no high presure switch to protect RO pump from back pressure. RO Electrical control panel. 1) Complete starter,overload relays,single phase preventer for pump 2)volt meter,ammeter,MCB,indicating light 3)push buttons 4)rocker switch for dozers 5)incommer auto-manual switchs 1 No. U.V. treatment with single wave-length UV for disinfection of 1 cum flow; UV dosage of 300 to 400 joules/sqm, with more than 90% UVT. The reverse osmosis block shall be duly supplemented with adequate pretreatment and post treatment equipmnet such as filter sodium metabisulphate dosing, anti-scalant dosing and post RO treatment pH correction dosing CIP etc. in line with the raw water characteristics and the required treated water parameters. The plant should consist of the following automation: The plant starts when the level at R.O. water storage tank is low and stops when the level at R.O. water storage tank is high When the level is low, the raw water pump starts. High pressure pumps starts after two minutes of starting of raw water pump The reject valve closes after 1 minute of starting of high pressure pump If the pressure at high pressure pumps suction is low / high, the plant trips When the plant stops due to high level, first the high pressure pump stops and the dump valves opens, after two minutes the raw water pumps and dosing pump stops When the connectivity is high an alarm is given The MIMIC provides indications for all the I/Ps and the respective O/Ps 1 No. HDPE Storage tank of Capacity 1500 liters for drinking water.

1

-

-

... More
Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 2 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required

8

-

-

... More
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. Group C

12

-

-

... More
Wiring for light/power plug with 2x4 sq.mm FR PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 1 No 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required.

60

-

-

... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire

175

-

-

... More
Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. 2 Pair

40

-

-

... More
Supplying and fixing of following sizes of PVC conduit along with accessories in surface / recess including painting in case of surface conduit, or cuttting the wall and making good the same in case of recessed conduit as required. 25 mm

175

-

-

... More
MB S/F metal boxes: Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required. 75 mm X 75 mm X 60 mm deep

11

-

-

... More
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 amps switch

6

-

-

... More
3 pin 5/6 amp socket outlet

6

-

-

... More
Telephone socket outlet

2

-

-

... More
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.

3

-

-

... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).

3

-

-

... More
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.

11

-

-

... More
Supplying and fixing 3 pin, 5 amp. ceilling rose on the existing junction box/ wooden block including connection etc. as required

3

-

-

... More
Supplying and flxing brass batten/angle holder including connection etc. as required.

6

-

-

... More
Installation, testing and commissioning of pre-wired, fluorescent fitting/ compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling / wall, including connection with 1.5 sq.mm FR PVC insulated, copper conductor, single core cable and earthing etc. as required.

3

-

-

... More
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq, mm FR PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.

3

-

-

... More
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 way (4 + 24), Double door

1

-

-

... More
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissoning etc. as required. 63 amps

3

-

-

... More
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole

5

-

-

... More
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc.with charcoal/ coke and salt as required..

3

-

-

... More
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)

60

-

-

... More
Supply, installation, testing & commissioning of Aircooled Variable Refrigerant Flow Modular Type Airconditioning System for R-410A refrigerent suitable for 415 ± 10% volt, 50 Hz., 3 phase AC supply for Outdoor Units and 220 ± 10% volt, 50 Hz., 1 phase AC supply for Indoor Units with stepless modulation complete with Indoor & Outdoor Units, individual remote controller & compatible for centralised controller, interconnected refrigerant piping, full charge of refrigerant gas and oil, control cabling etc. as per site requirements & details given in the specifications as listed below complete in all respects including foundation and anti vibration pads for ODUs. Heat Pumps having cooling COP not less than 3.8 at 100% loading at ARI standards and conditions equipped with highly efficient inverter scroll / rotary compressor(s), special heat exchanger, low noise condenser fan, auto check function for connection error, auto address setting and minimum capacity as mentioned below, complete with all accessories. ODU- 60 HP (47.5 TR Nominal Cooling Capacity) complete including necessary copper piping and jointing kit for combining the constituent units.

2

-

-

... More
ODU- 48 HP (38.1 TR Nominal Cooling Capacity) complete including necessary copper piping and jointing kit for combining the constituent units.

6

-

-

... More
ODU- 40 HP (31.8 TR Nominal Cooling Capacity) complete including necessary copper piping and jointing kit for combining the constituent units.

6

-

-

... More
ODU- 26 HP (20.6 TR Nominal Cooling Capacity) complete including necessary copper piping and jointing kit for combining the constituent units.

12

-

-

... More
ODU – 14 HP (11.4 TR Nominal Cooling Capacity) complete including necessary copper piping and jointing kit for combining the constituent units.

8

-

-

... More
ODU – 10 HP (7.9 TR Nominal Cooling Capacity) complete including necessary copper piping and jointing kit for combining the constituent units.

4

-

-

... More
ODU – 8 HP (6.4 TR Nominal Cooling Capacity) complete including necessary copper piping and jointing kit for combining the constituent units.

4

-

-

... More
Supply, installation, testing and commissioning of Indoor Units for Variable Refrigerant Flow Airconditioning System suitable for 220 ± 10% volt, 50 Hz, 1 phase AC supply equipped with synthetic washable media type filter arranged for convenient cleaning & replacement, fan section with low noise fan, multispeed motor, coil section with DX (Direct Expansion) Coil, Outer Cabinet, Electronic Expansion Valve, insulated drain pan, insulation, pipe connections, etc. complete with 3 core PVC insulated FRLS copper conductor electric wire for electrically connecting the IDU with minimum capacity as given below as per specifications & drawings. Hi-Wall 1.5 TR Cooling Capacity with 500 cfm airflow rate complete with Corded Remote Controller.

6

-

-

... More
Hi-Wall 1.0 TR Cooling Capacity with 300 cfm airflow rate complete with Corded Remote Controller.

4

-

-

... More
Supply, installation, testing & commissioning of Indoor Units for variable refrigerant flow airconditioning system suitable for 220 ± 10% volt, 50 Hz, 1 phase AC supply equipped with synthetic washable media type filters arranged for convenient cleaning and replacement fan section with low noise fan, multispeed motor, coil section with DX (Direct Expansion) coil, Electronic Expansion Valve,outer cabinet, insulated drain pan, built in drain water lift-up pump, pipe connections, fresh air intake etc. complete with 3 core PVC insulated FRLS copper conductor electric wire for electrically connecting the IDU with minimum capacity as given below as per specifications and drawings. Ceiling Mounted Cassette Four Way Flow with Cassette Panel 0.8 TR Cooling Capacity with 318 cfm airflow complete with Corded Remote Controller.

4

-

-

... More
Ceiling Mounted Cassette Four Way Flow with Cassette Panel 1.0 TR Cooling Capacity with 335 cfm airflow complete with Corded Remote Controller.

2

-

-

... More
Ceiling Mounted Cassette Four Way Flow with Cassette Panel 1.3 TR Cooling Capacity with 530 cfm airflow complete with Corded Remote Controller.

2

-

-

... More
Ceiling Mounted Cassette Four Way Flow with Cassette Panel 2.0 TR Cooling Capacity with 670 cfm airflow complete with Corded Remote Controller.

82

-

-

... More
Supply, installation, testing & commissioning of Indoor Units for Variable Refrigerant Flow Airconditioning System suitable for 220 ± 10% volt, 50 Hz, 1 phase AC supply equipped with synthetic washable media type filter arranged for convenientt cleaning and replacement, fan section with low noise fan, multispeed motor, coil section with DX (Direct Expansion) coil, Electronic Expansion Valve, outer cabinet, insulated drain pan, built in drain water lift-up pump, insulation, pipe connections, fresh air intake etc. complete including fire retradant non-porous double layer thermally insulated flexible connection between Ductable Outlet and Supply Air Duct/Supply Air Grille complete with 3 core PVC insulated FRLS copper conductor electric wire for electrically connecting the IDU and with minimum capacity as given below as per specifications and drawings. Ceiling Concealed Ductable Unit 3.3 TR Cooling Capacity with 1130 cfm air flow and 100 Pa external static pressure complete with Corded Remote Controller.

8

-

-

... More
Ceiling Concealed Ductable Unit 4.0 TR Cooling Capacity with 1377 cfm air flow and 100 Pa external static pressure complete with Corded Remote Controller.

8

-

-

... More
Ceiling Concealed Ductable Unit 4.6 TR Cooling Capacity with 1624 cfm air flow and 100 Pa external static pressure complete with Corded Remote Controller.

12

-

-

... More
Ceiling Concealed Ductable Unit 6.2 TR Cooling Capacity with 2133 cfm air flow and 100 Pa external static pressure complete with Corded Remote Controller.

20

-

-

... More
Ceiling Concealed Ductable Unit 8.2TR Cooling Capacity with 2820 cfm air flow and 100 Pa external static pressure complete with Corded Remote Controller.

28

-

-

... More
Ceiling Concealed Ductable Unit 11TR Cooling Capacity with 3778 cfm air flow and 100 Pa external static pressure complete with Corded Remote Controller.

16

-

-

... More
Supply, installation, testing & commissioning of Indoor Units for Variable Refrigerant Flow Airconditioning System suitable for 220 ± 10% volt, 50 Hz, 1 phase AC supply equipped with synthetic washable media type filter arranged for convenientt cleaning and replacement, fan section with low noise fan, multispeed motor, coil section with DX (Direct Expansion) coil, Electronic Expansion Valve, outer cabinet, insulated drain pan, built in drain water lift-up pump, insulation, pipe connections, fresh air intake etc. complete including fire retradant non-porous double layer thermally insulated flexible connection between Ductable Outlet and Supply Air Duct / Supply Air Grille complete with 3 core PVC insulated FRLS copper conductor electric wire for electrically connecting the IDU and with minimum capacity as given below as per specifications and drawings. Ceiling Concealed Treated Fresh Air Unit: 8.0 TR Cooling Capacty with 1600 cfm airflow and 200 Pa external static pressure complete with Corded Remote Controller

4

-

-

... More
Ceiling Concealed Treated Fresh Air Unit: 11 TR Cooling Capacty with 2500 cfm airflow and 200 Pa external static pressure complete with Corded Remote Controller

6

-

-

... More
Ceiling Concealed Treated Fresh Air Unit: 6.4 TR Cooling Capacty with 988 cfm airflow and 200 Pa external static pressure complete with Corded Remote Controller

12

-

-

... More
Providing & fixing Transmission / Control Wiring PVC insulated of 2 core x 1.5 sq.mm copper conductor shielded flexible wire in 25 mm M.S. Conduits between outdoor to outdoor/indoor to indoor/outdoor to indoor & remote control unit.

2400

-

-

... More
Supply, installation, testing and commissioning of Copper Y-Joints suitable for gas and liquid line of VRF System complete as required for the above system.

168

-

-

... More
Supply, installation, testing and commissioning of following interconnecting Copper Refrigerant Pipe suitable for VRF System of airconditioning conforming to JISH 3300: 1997, recessed/concealed or laid and supported on the existing slotted cable trays, duly insulated with closed cell elastomeric nitrile rubber tubular insulation of nominal thickness as specified between indoor and outdoor units as per specifications including protective coating on pipes exposed to sunlight. 41.3 mm OD with minimum 1.30 mm wall thickness (Insulation : 25 mm)

180

-

-

... More
34.9 mm OD with minimum 1.20 mm wall thickness (Insulation : 25 mm)

192

-

-

... More
28.6 mm OD with 1.00 mm wall thickness (Insulation : 25 mm)

400

-

-

... More
25.4 mm OD with minimum 1.00 mm wall thickness (Insulation : 25 mm)

20

-

-

... More
22.2 mm OD with 0.80 mm wall thickness (Insulation : 25 mm)

108

-

-

... More
19.1 mm OD with 0.80 mm wall thickness (Insulation : 19 mm)

516

-

-

... More
15.9 mm OD with 1.00 mm wall thickness (Insulation : 19 mm)

600

-

-

... More
12.7 mm OD with 0.80 mm wall thickness (Insulation : 19 mm)

660

-

-

... More
9.5 mm OD with 0.80 mm wall thickness (Insulation : 19 mm)

620

-

-

... More
6.35 mm OD with 0.80 mm wall thickness (Insulation : 19 mm)

440

-

-

... More
Supply, installation, testing and commissioning of following Drain Piping made of Rigid uPVC Pipe Class - 3 (6 kg/cm2) confirming to IS: 4985-2000 complete with fittings, supports etc. as per specifications and duly insulated with 9 mm thick Closed Cell Nitrile Rubber Insulation. 32 mm dia

460

-

-

... More
40 mm dia

190

-

-

... More
Supply, installation, testing and commissioning of Corded Centralised Type Remote Controllers capable of monitoring and controlling all Outdoor and Indoor Units etc. as required. The Central Control Unit shall be suitable for ON/OFF and Temperature Control of areas including scheduling, Malfunction and status display. Setting of address for each Unit should be automatic and need not be programmed.

1

-

-

... More
Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. Thickness 0.63 mm sheet (24 G)

3900

-

-

... More
Thickness 0.80 mm sheet (22 G)

1900

-

-

... More
Thickness 1.00 mm sheet (20 G)

100

-

-

... More
Thickness 1.25 mm sheet (18 G)

100

-

-

... More
Supply, installation, balancing and commissioning of site fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. Thickness 0.63 mm sheet (24 G)

1350

-

-

... More
Thickness 0.80 mm sheet (22 G)

412

-

-

... More
Thickness 1.00 mm sheet (20 G)

80

-

-

... More
Thickness 1.25 mm sheet (18 G)

170

-

-

... More
Supply, installation, balancing and commissioning of factory fabricated Aluminium sheet metal rectangular / round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required. Thickness 1.25 mm sheet (18 G)

850

-

-

... More
Supply, fixing, testing & commissioning of following powder coated extruded aluminium grilles complete with nuts, bolts, screws etc. as per approved drawings and specifications. Supplying & fixing of powder coated extruded aluminium Supply Air Grills with aluminium volume control dampers as per specifications.

300

-

-

... More
Supplying & fixing of powder coated extruded aluminium Return Air Grills with louvers but without volume control dampers complete as required.

300

-

-

... More
Supplying, fixing testing commissioning of supply air diffusers of powder coated aluminium with aluminium volume control dampers with anti smudge ring & removable core.

60

-

-

... More
Supplying, fixing testing commissioning of Return air diffusers of powder coated aluminium without volume control dampers with anti smudge ring & removable core.

60

-

-

... More
Supplying, fixing, testing and commissioning of GI Volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screw, linkages, flenges etc. as per specification.

30

-

-

... More
Supplying, fixing, testing and commissioning of Fire Dampers in supply Air Duct/Main Branch and Return Air Path as and where required of required sizes i/c control wiring, the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal complete as required and as per specifications. Fire damper

34

-

-

... More
Actuator

96

-

-

... More
Supply, fixing, testing and commissioning of powder coated extruded aluminium section Fresh/Exhaust air Louver with bird screen with rain protection, 12x12x1.5 mm aluminium wire mesh, Aluminium sheet fillter frame with Expanded Aluminium media fillter complete with flanges, nuts, bolts, screws etc. complete as required.

40

-

-

... More
Supply and fixing of acoustic lining of supply air duct and plenum with 25 mm thick resin bonded glass wool having density of 32 kg/m³, with 25 mm X 25 mm GI section of 1.25 mm thick, at 600 mm centre to centre covered with Reinforced Plastic tissue paper and 0.5 mm thick perforated aluminum sheet fixed to inside surface of ducts with cadmium plated nuts, bolts, stick pins, CPRX compound etc. complete as required and as per specifications.

654

-

-

... More
Supplying and fixing of following thickness duly laminated aluminum foil of mat finish closed cell Nitrile Rubber (class “O”) insulation on existing duct after applying two coats of cold setting adhesive (CPRX compound). The joints shall sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required. 19mm

4400

-

-

... More
Supplying and fixing 50 mm thick aluminium foil faced resin bonded fibre glass insulation (on duct) of density 24 kg/cu.m or mineral wool insulation(non combustible) of density 44 kg/ cu m after applying two coats of cold setting adhesive (CPRX compound) sealing all joints with self adhesive aluminium tape & covering with 0.63mmx19mm GI wire mesh netting & butting all joints and laced with GI wire complete and finally covered with one layer of tar felt stuck with hot bitumen as per specifications and as required. (for outdoor applications)

850

-

-

... More
TUBE AXIAL FAN FOR LIFT WELL PRESSURISATION Supplying, installation, testing and commissioning of AMCA Certified Tube Axial fan with G S S casing, and aluminium alloy impellers with aerofoil blades, the impeller directly driven by TEFC induction motor IP-55 protection suitable for 3 Phase 50 Hz 415 V ± 10 %, of class 'F' insulation. Fans after assembly shall be dynamically trim-balanced to ISO1940 and AMCA 204/5 - G2.5 quality grade. Casing shall have flanged connection as both ends for ducted application canvass connection at outlet side, multi louvers damper with bird screeen and rain protection at inlet side in GI construction with casing in 16 G & louvers in 18 G construction, foundation bolts, common base frame in standard MS construction, anti vibration mountings arrangement. The fan capacity shall be as follows. 7000 CFM (25 mm external static pressure) Fan for Lift Well Pressurisation

8

-

-

... More
Supplying, installation, testing and commissioning of AMCA Certified Tube Axial fan with G S S casing, and aluminium alloy impellers with aerofoil blades, the impeller directly driven by TEFC induction motor IP-55 protection suitable for 3 Phase 50 Hz 415 V ± 10 %, of class 'F' insulation. Fans after assembly shall be dynamically trim-balanced to ISO1940 and AMCA 204/5 - G2.5 quality grade. Casing shall have flanged connection as both ends for ducted application canvass connection at outlet side, multi louvers damper with bird screeen and rain protection at inlet side in GI construction with casing in 16 G & louvers in 18 G construction, foundation bolts, common base frame in standard MS construction, anti vibration mountings arrangement. The fan capacity shall be as follows. 15000 CFM (30 mm external static pressure) Fan for Lift Lobby Pressurisation

2

-

-

... More
Supplying, installation, testing and commissioning of AMCA Certified (For Air Performance) Tube Axial fan for supply air with G S S casing, having manually adjustable pitch dia cast aluminium alloy impeller blades, the impeller directly driven by TEFC induction motor IP-55 protection suitable for 3 Phase 50 Hz 415 V ± 10%, of class 'F' insulation. Fans after assembly shall be dynamically trim-balanced to ISO 1940 and AMCA 204/5 - G2.5 quality grade. Casing shall have flanged connection at one end for ducted application, canvass connection, multi louvers damper with bird screeen and rain protection at inlet side in GI construction with casing in 16 G & louvers in 18 G construction, anti vibration mountings arrangement etc. The fan shall be complete with DOL Starter and of following capacities: 3000 CFM at 20 mm static pressure

4

-

-

... More
2500 CFM at 20 mm static pressure

4

-

-

... More
2000 CFM at 20 mm static pressure

4

-

-

... More
1800 CFM at 20 mm static pressure

4

-

-

... More
1200 CFM at 20 mm static pressure

12

-

-

... More
Supplying, installation, testing and commissioning of AMCA Certified (For Air Performance) Tube Axial fan for Smoke Exhaust air with G S S casing, having manually adjustable pitch dia cast aluminium alloy impeller blades, the impeller directly driven by TEFC induction motor IP-55 protection suitable for 3 Phase 50 Hz 415 V ± 10%, of class 'H' insulation. Fan and Motor shall be certified by an independant inernational laboratory as per BS EN 12101-3:2002 for operation at minimum 250 deg C for 2 hrs and test reports shall be submitted for the same. Fans after assembly shall be dynamically trim-balanced to ISO 1940 and AMCA 204/5 - G2.5 quality grade. Casing shall have flanged connection at one end for ducted application, canvass connection, multi louvers damper with bird screeen and rain protection at outlet side in GI construction with casing in 16 G & louvers in 18 G construction, anti vibration mountings arrangement etc. The fan shall be complete with DOL Starter and of following capacities: 3000 CFM at 20 mm static pressure

4

-

-

... More
2500 CFM at 20 mm static pressure

4

-

-

... More
2000 CFM at 20 mm static pressure

4

-

-

... More
1800 CFM at 20 mm static pressure

4

-

-

... More
1200 CFM at 20 mm static pressure

12

-

-

... More
Supply, installation, testing and commissioning of Inline Fan for exhaust ventilation suitable for 220±10% volts, 50 ± 3% Hz, single phase AC supply direct driven and complete with all standard accessories such as motors, blades, mounting bracket etc. The casing of inline fan shall be accoustically lined and shall be selected for lower noise level. Fan motor shall have inbuilt speed controller. Provision of connection with 1.5 sq. mm PVC insulated FRLS copper conductor wire upto maximum of 3 mtrs from the point outlet to the fan as required shall be deemed to be included in this cost. Fan shall be provided with gravity louvers to avoid back flow and suitable starter panel. 1200 cfm, 25 mm static pressure

2

-

-

... More
700 cfm, 20 mm static pressure

12

-

-

... More
500 cfm, 20 mm static pressure

6

-

-

... More
480 cfm, 20 mm static pressure

2

-

-

... More
300 cfm, 20 mm static pressure

4

-

-

... More
100 cfm, 15 mm static pressure

10

-

-

... More
Supply of Floor mounted SISW fans for kitchen exhaust. Centrifugal fan shall be SISW/DIDW Class having bearings on both the sides, Fan Wheel shall be backward-curved non-over loading type. Fan wheel and housing shall be statically and dynamically balanced.Fan motor shall be energy efficient and suitable for 415±10% volts, 50 cycles, 3 phase AC power supply, squirrel-cage, totally enclosed, fan-cooled motor, provided with class F insulation, motor speed shall not exceed 1440 rpm. 13000 CFM - 60 MM SP

1

-

-

... More
5500 CFM - 60 MM SP

2

-

-

... More
4000 CFM - 60 MM SP

1

-

-

... More
3000 CFM - 60 MM SP

1

-

-

... More
Dry scrubber having Electrostatic Air cleaners section, Ionizing-Collecting cell(s),2 LED lights for status, Ozone generating UVC lamps having minimum 25 watts per 1000 CFM of exhaust air quantity, Lamp life shall be minimum 9000 hours, with drop in efficiency not more than 20% at the end of the life cycle. 13000 CFM - 60 MM SP

1

-

-

... More
5500 CFM - 60 MM SP

2

-

-

... More
4000 CFM - 60 MM SP

1

-

-

... More
3000 CFM - 60 MM SP

1

-

-

... More
Supply, installation, testing and commissioning of synthetic fill pad type double skin air washer at 600 FPM velocity across pads, DIDW Class-I forward curved centrifugal fan (to be tested as per AMCA) with TEFC weather proof motor of IP:55 protection suitable for 415 +10% Volts, 3 phase, 50 cycles power supply, mounted on a common base with metallistik vibration isolators, multi sheave pullies for fan and fan motor (drive pulleys to be taper brushed duly balanced with proper size V-belts). The fan capacity shall be based on outlet velocity not exceeding 2000 FPM. Air Washer to be fitted with pressure gauge to measure the TSP with high accurnacy, as specified in item below. The fan to be selected for high performance efficiency including its motor (vendor need to submit the detailed fan performance curves and certificates for approvals along with apporval docuements for Air washer, before supply). The cooler shall be complete with 8" thick celdek fill, 3mm thick FRP steel reinforced tank, water pump 2 Nos. (1+1), cover pipe, distribution pipe, distribution pan, filters at air inlet, internal water piping, make up water with ball valve, drain and overflow connection, Y-strainer for inlet water, all housed in 16 G GSS casing mounted on heay duty vibration isolators complete in all respects as per specifications and drawings. Each of the cooler to be supplied with local starter (ON/OFF) panel, planned such that single feeder cable to this will be supplied through other contractor. This local starter panel to be mounted on the AW body for each installation. Vendor need to submit the GA (to be made inline with tender drawings) and take due approvals from Consultant, before starting the fabrication of Air Washer 13000 CFM

1

-

-

... More
5500 CFM

2

-

-

... More
4000 CFM

1

-

-

... More
3000 CFM

1

-

-

... More
Supply, installation, testing and commissioning of MV Panel Boards cubical type, compartmentailsed design fabricated from 2 mm thick CRCA sheet having necessary cable alleys, powder coated coated through nine tank process factility for pricking and degreasing, dust and vermin proof, suitable for operation on 440 V 3 phase, 50 Hz, A.C. supply rupturing capacity 35 MVA with necessary MCCBs/MCBs/MPCBs and other accessories, IP 44 Protection complete in all respects including internal wiring, labels, ferrules, cable termination, gland plates, earth terminals, painting etc. conforming to specifications. All MCCB shall be with Rotary handle and pad locking arrangements complete with incoming and outgoing feeders and accessories as described below: STARTER PANEL FOR LIFT WELL PRESSURISATION (TERRACE) 7000 CFM FOR 2.2 KW MOTOR 1 (One no.) MPCB with contactors & relays with over current and short circuit thermal/ magnetic releases and fully automatic DOL Starter suitable for 2.2 KW Tube Axial Fan with built in single phase preventer, overload relay, NO/NC for remote operation, a set of On and Off indication lights and Start/Stop push button. (Selection of MPCBs contactors and relays for starters to be done for fuseless protection as per Type 2 co-ordination) Control wiring and safety circuit as required with indicating lights and on off push button Potential free contacts to BMS

4

-

-

... More
STARTER PANEL FOR LIFT LOBBY PRESSURISATION (TERRACE) 15000 CFM FOR 5.5 KW MOTOR 1 (One no.) MPCB with contactors & relays with over current and short circuit thermal/ magnetic releases and fully automatic DOL Starter suitable for 5.5 KW Tube Axial Fan with built in single phase preventer, overload relay, NO/NC for remote operation, a set of On and Off indication lights and Start/Stop push button. (Selection of MPCBs contactors and relays for starters to be done for fuseless protection as per Type 2 co-ordination) Control wiring and safety circuit as required with indicating lights and on off push button Potential free contacts to BMS

2

-

-

... More
Supply, Laying of PVC insulated PVC sheathed unarmoured copper conductor cable, 1100 volts enclosed in the GI flexible conduit of suitable size complete with end terminations, connections etc as required for the following sizes. 4 C x 16 Sq.mm

720

-

-

... More
4 C x 10 Sq.mm

380

-

-

... More
4 C x 6 Sq.mm

180

-

-

... More
Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 150 mm width X 50 mm depth X 1.6 mm thickness

1650

-

-

... More
300 mm width X 50 mm depth X 1.6 mm thickness

280

-

-

... More
Supplying and installing following size of perforated pre-painted M.S. cable trays bends with perforation not more than 17.5%,, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 150 mm width X 50 mm depth X 1.6 mm thickness

36

-

-

... More
300 mm width X 50 mm depth X 1.6 mm thickness

18

-

-

... More
Supplying and installing following size of perforated pre-painted M.S. cable trays reducers with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 150 mm width X 50 mm depth X 1.6 mm thickness

18

-

-

... More
300 mm width X 50 mm depth X 1.6 mm thickness

12

-

-

... More
Supplying and installing following size of perforated pre-painted M.S. cable trays Tee's with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 150 mm width X 50 mm depth X 1.6 mm thickness

28

-

-

... More
300 mm width X 50 mm depth X 1.6 mm thickness

8

-

-

... More
Supplying and installing following size of perforated pre-painted M.S. cable trays cross members with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 150 mm width X 50 mm depth X 1.6 mm thickness

10

-

-

... More
300 mm width X 50 mm depth X 1.6 mm thickness

6

-

-

... More
Earthing Strip/Wires Providing & fixing 25mm x 5mm G.I. Strip on surface or in recess for earth connection etc. as required.(For ODUs)

600

-

-

... More
Supply and installation of Residual Current Circuit Breaker in Outdoor Weather Proof sheet steel cubical of IP 65 protection complete for protection of ODU against earth leakege fault suitable for wall mounting including MS frame work, internal wiring, painting, earthing etc. of capacity as follows: 40 Amps 4 pole with 300 mA sensitivity.

48

-

-

... More
63 Amps 4 pole with 300 mA sensitivity.

12

-

-

... More
100 Amps 4 pole with 300 mA sensitivity.

10

-

-

... More
Supplying of heavy duty XLPE insulated PVC sheathed armoured electric cable with Aluminium conductor for working voltage upto & including 1.1 KV conforming to IS 7098 duly ISI marked of sizes. 3.5 C x 35 Sqmm.

360

-

-

... More
4 C x 16 Sqmm.

280

-

-

... More
4 C x 10 Sqmm.

160

-

-

... More
4 C x 6 Sqmm.

450

-

-

... More
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. Upto 35 sq. mm (clamped with 1mm thick saddle)

1250

-

-

... More
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. Upto 35 sq. mm (clamped with 1mm thick saddle)

1250

-

-

... More
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3.5 core, 35 Sq.mm.

24

-

-

... More
4 core, 6 Sq.mm.

96

-

-

... More
4 core, 10 Sq.mm.

60

-

-

... More
4 core, 16 Sq.mm.

32

-

-

... More
Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm Sand Cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests

1

-

-

... More
Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/6 litre (adjustable to 4 litre/8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete.

63

-

-

... More
Providing and fixing 8 mm dia C.P/ S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer-in-Charge

63

-

-

... More
Providing and fixing toilet paper holder : C.P. brass

63

-

-

... More
Providing and fixing of C.P. 2 Way bib cock (Jaquar - FON-40041/ Cera - CQ 706A / Hindware - F130019) with wall flange alongwith all necessary accessories complete including cutting, making good the walls, floors, slab wherever required as per direction of Engineer-Incharge.

63

-

-

... More
Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required Range of four half stall urinals with 10 litre PVC. automatic flushing cistern

52

-

-

... More
Providing and fixing white vitreous china Urinals Partitions alongwith all necessary accessories complete including cutting, making good the walls, floors, slab wherever required as per direction of Engineer-Incharge. (Cera - 5011 (Snow White) Hindware 61001 (Starwhite))

52

-

-

... More
Providing and fixing wash basin with C.I. brackets, 15 mm dia C.P. Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required :- White Vitreous China Wash basin size 550x400 mm with a 15 mm C.P. Brass single hole basin mixer.

53

-

-

... More
Providing and fixing of White vitreous china under counter Oval Wash Basin (Jaquar - CNS-WHT-601/ Cera - 1005D / Hindware - 10049) with CI bracket, including waste coupling 32 mm half threaded (Jaquar - ALD-705 / Cera - CM203 / Hindware - F850001) including painting of fitting & bracket, cutting and making good the walls, floors, slab wherever required as per direction of Engineer-Incharge.

10

-

-

... More
Providing and fixing of Single Lever C.P. Pillar Trap (Jaquar - FON 40011, / Cera - CS-201A, / Hindware - F130001) with 450 mm long stainless steel flexible hose, alongwith all necessary accessories complete including cutting, making good the walls, floors, slab wherever required as per direction of Engineer-Incharge.

63

-

-

... More
Providing and fixing C.P. liquid Soap Dispenser With Glass Bottle / Stainless steel (Euronices - ES14H / Jaquar - ACN-1135N) alongwith all necessary accessories complete including cutting, making good the walls, floors, slab wherever required as per direction of Engineer-Incharge.

63

-

-

... More
Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS 13983 with C.I. brackets and stainless steel plug 40 mm including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board 510x1040 mm bowl depth 250 mm.

15

-

-

... More
Kitchen sink without drain board 610x460 mm bowl depth 200 mm.

18

-

-

... More
Providing and fixing CP Brass 32 mm size Bottle Trap of approved quality & make and as per the direction of Engineer-In-Charge.

96

-

-

... More
Providing and fixing of Single Lever C.P. Sink Mixer with shower pollout with 1.5 mtr double lock flexible hose, wall mounted (Jaquar - FUS-29163 / Cera - CS231A / Hindware - F130013) alongwith all necessary accessories complete including cutting, making good the walls, floors, slab wherever required as per direction of Engineer-Incharge.

33

-

-

... More
Providing and fixing of C.P. Soap Dish (Jaquar - ACN-1131N / Cera - CA306 / Hindware - F870004) alongwith all necessary accessories complete including cutting, making good the walls, floors, slab wherever required as per direction of Engineer-Incharge.

33

-

-

... More
Providing and fixing of Towel Ring (Jaquar - ACN-1121BN / Cera - CA102 / Hindware-F880007) alongwith all necessary accessories complete including cutting, making good the walls, floors, slab wherever required as per direction of Engineer-Incharge.

33

-

-

... More
Providing and fixing of Towel Shelf / Rack (ACN-1181N / Cera - CA302 / Hindware-F880008) alongwith all necessary accessories complete including cutting, making good the walls, floors, slab wherever required as per direction of Engineer-Incharge.

10

-

-

... More
Providing and fixing of Robe Hook, (Jaquar - ACN-1161N / Cera - CA608 / Hindware-F880004) alongwith all necessary accessories complete including cutting, making good the walls, floors, slab wherever required as per direction of Engineer-Incharge.

63

-

-

... More
Providing, Fixing, Testing and Commissioning of C.P. bath and shower fittings comprising of : (Jaquar- KUB-35421F, OHS-1789, SHA-CHR-483/ Cera - CDC501, CS 234E, CQ440 / Hindware -F220018, F160054) 1 No. CP Wall mixer with hand and overhead shower arrangement. 1 No. Over Head Shower consisting of arm with wall flange complete in all respect .

1

-

-

... More
Providing and fixing of automatic Hand Dryer with time delay, on/off cable upto plug, alongwith all necessary accessories complete as required. (Jaquar - HDR-WHT-M04A / Euronices -EH 27NW)

12

-

-

... More
Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :Rectangular shape 453x357mm

63

-

-

... More
Providing and fixing brass bib cock of approved quality. 15 mm nominal bore

126

-

-

... More
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 a) 15 mm nominal bore 15 mm nominal bore

252

-

-

... More
Providing and fixing soil, waste and vent pipes : Centrifugally cast (spun) iron socket & spigot (S&S) pipe as per IS: 3989 100 mm dia.

2440

-

-

... More
Centrifugally cast (spun) iron socket & spigot pipe as per IS: 3989 75 mm dia.

740

-

-

... More
Providing and fixing M.S. holder-bat clamps of approved design to Sand Cast iron/cast iron (spun) pipe embedded in and including cement concrete blocks 10x10x10cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) including cost of cutting holes and making good the walls etc. : For 100 mm dia. Pipe

970

-

-

... More
For 75 mm dia. Pipe

200

-

-

... More
Painting sand cast iron/ centrifugally cast (spun) iron soil, waste vent pipes and fittings with two coats of synthetic enamel paint of any colour such as chocolate grey, or buff etc. over a coat of primer (of approved quality) for new work : 100 mm diameter pipe

2615

-

-

... More
75 mm diameter pipe

600

-

-

... More
Providing and fixing plain bend of required degree. Sand cast iron S&S as per IS : 3989 100 mm

75

-

-

... More
75 mm

15

-

-

... More
Providing and fixing double equal junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete : 100x100x100x100mm Sand cast iron S&S as per IS - 3989

40

-

-

... More
Providing and fixing single equal plain junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. 100x100x100 mm Sand cast iron S&S as per IS - 3989

340

-

-

... More
Providing and fixing single unequal junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. 100x100x75 mm Sand cast iron S&S as per IS - 3989

104

-

-

... More
Providing and fixing plain tee of required degree. Sand cast iron S&S as per IS : 3989 100 mm

195

-

-

... More
Providing and fixing terminal guard: Sand cast iron S&S as per IS - 3989 100 mm

72

-

-

... More
75 mm

30

-

-

... More
Providing drip seal joints to sand cast iron/centrifugally cast (spun) iron pipes and fittings of diameter: 100 mm

1150

-

-

300

-

-

... More
Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : 100 mm inlet and 100 mm outlet Sand cast iron S&S as per IS: 3989.

230

-

-

... More
Providing and fixing flanged cleanout plug with flanged tail pieces, blind flang, 6mm dia nut & bolts, gasket and washers fixed to C.I. Pipe with drip seal joint complete in all complete including testing of joints complete as per direction of Engineer in Charge. 100 mm dia

92

-

-

... More
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc.(for waste) 32 mm dia. nominal bore

485

-

-

... More
40 mm dia. nominal bore

30

-

-

... More
50 mm dia. nominal bore

130

-

-

... More
Making chases up to 7.5x7.5 cm in walls including making good and finishing with matching surface after housing G.I. pipe etc. For dia 32 mm nominal bore to 50 mm nominal bore

440

-

-

... More
Providing and fixing Nahani Trap / Floor Drain including all fitting and accessories fixed in cement mortar complete in all respect. This includes the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 100 x 75 mm

126

-

-

... More
Providing and fixing 100% stainless steel "cockroach" trap of approved make and quality on top of floor trap. The rate includes the cost of all ancillary works as required to complete the work.This includes the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. (Chilly Model No. CCT-R-101-Glossy / Jayna NRB 127- Glossy).

315

-

-

... More
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.

2000

-

-

... More
COLD WATER SUPPLY SYSTEM Providing and fixing enclosed type water meter (bulk type) conforming to IS : 2373 and tested by Municipal Board complete with bolts, nuts, rubber insertions etc. (The tail pieces if required will be paid separately) : 80 mm dia nominal bore

4

-

-

... More
Providing and fixing C.I. dirt box strainer for bulk type water meter with nuts, bolts, rubber insertions etc. complete conforming to IS : 2373: 80 mm dia nominal bore

4

-

-

... More
Providing and fixing solid state water level controllers for low and high level cut off for overhead tank installation, complete.

6

-

-

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. (Pipe upto 50 dia shall be SDR-11, and above 50 dia - SCH 40) Internal work - Exposed on Wall 15 mm nominal outer dia Pipes

300

-

-

... More
20 mm nominal outer dia Pipes

545

-

-

... More
25 mm nominal outer dia Pipes

435

-

-

... More
32 mm nominal outer dia Pipes

430

-

-

... More
40 mm nominal outer dia Pipes

455

-

-

... More
50 mm nominal outer dia Pipes

345

-

-

... More
65 mm nominal outer dia Pipes

155

-

-

... More
80 mm nominal outer dia Pipes

116

-

-

... More
100 mm nominal outer dia Pipes

110

-

-

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.,15 mm nominal outer dia Pipes

600

-

-

... More
20 mm nominal outer dia Pipes

400

-

-

... More
25 mm nominal outer dia Pipes

300

-

-

... More
32 mm nominal outer dia Pipes

250

-

-

... More
40 mm nominal outer dia Pipes

50

-

-

... More
50 mm nominal outer dia Pipes

20

-

-

... More
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement ,trenching ,refilling & testing of joints complete as per direction of Engineer in Charge. External work 20 mm nominal outer dia Pipes

55

-

-

... More
25 mm nominal outer dia Pipes

80

-

-

... More
40 mm nominal outer dia Pipes

120

-

-

... More
50 mm nominal outer dia Pipes

180

-

-

... More
75 mm nominal inner dia Pipes

240

-

-

... More
100 mm nominal inner dia Pipes

20

-

-

... More
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 25 mm nominal bore

25

-

-

... More
20 mm nominal bore

25

-

-

... More
32 mm nominal bore

15

-

-

... More
40 mm nominal bore

25

-

-

... More
50 mm nominal bore

15

-

-

... More
65 mm nominal bore

15

-

-

... More
80 mm nominal bore

6

-

-

... More
100 mm nominal bore

1

-

-

... More
Providing, installation, testing and commissioning of Y-strainer of CI body fabricated out of 1.6 mm. thick stainless steel sheet with 3 mm. dia holes with stainless steel flanged. 65 mm dia

2

-

-

... More
80 mm dia

2

-

-

... More
100 mm dia

2

-

-

... More
Supplying, fixing, testing and commissioning of following valves, gauge and strainers for condenser water circulation as per specifications. BUTTERFLY VALVE (MANUAL) with CI body SS disc nitrile sheet & O-ring & PN 16 pressure rating as specified. 100 mm dia

8

-

-

... More
80 mm dia

9

-

-

... More
65 mm dia

2

-

-

... More
Providing and fixing gun metal non- return valve of approved quality (screwed end) : 40 mm nominal bore Horizontal

2

-

-

... More
Vertical

3

-

-

... More
Horizontal 50 mm nominal bore

2

-

-

... More
Vertical 50 mm nominal bore

2

-

-

... More
Horizontal 65 mm nominal bore

4

-

-

... More
Providing and fixing forged brass body suitably nickle plated Auto Air Vent Valve of PN 10 rating complete suitable for domestic cold water supply. 20 mm dia

4

-

-

... More
25 mm dia

2

-

-

... More
Providing and fixing thermal insulation of all hot water CPVC pipe with Closed Cell Elastometric Nitrile rubber insulation, duly finished with Aluminium cladding, class 'O' fire rating having density of 50 kg/m3 and with K value not exceeding 0.035 W/mK at mean temerature of 0o C and thickness as specified. Fixing of insulation of be done complete as per direction of Engineer in Charge. 15 mm nominal outer dia pipes (13 mm thickness nitrile rubber)

100

-

-

... More
20 mm nominal outer dia pipes (13 mm thickness nitrile rubber)

350

-

-

... More
25 mm nominal outer dia pipes (13 mm thickness nitrile rubber)

350

-

-

... More
32 mm nominal outer dia pipes (13 mm thickness nitrile rubber)

450

-

-

... More
40 mm nominal outer dia pipes (13 mm thickness nitrile rubber)

120

-

-

... More
50 mm nominal outer dia pipes (13 mm thickness nitrile rubber)

155

-

-

... More
65 mm nominal outer dia pipes (13 mm thickness nitrile rubber)

80

-

-

... More
80 mm nominal outer dia pipes (13 mm thickness nitrile rubber)

20

-

-

... More
100 mm nominal outer dia pipes (13 mm thickness nitrile rubber)

75

-

-

... More
Supply, installation, testing & commissioning of G.I. Pipes Class 'C' conforming to I.S. 1239 (Heavy grade) with G.I. Fittings conforming to IS : 1879 such as tees, crosses, plugh, socket, elbows, reducers, flange, check nut, flanges & clamps, hanger, structural steel supports as required/directed at Site including cutting and making good the same etc. complete. 100 mm dia

25

-

-

... More
80 mm dia

25

-

-

... More
65 mm dia

45

-

-

... More
50 mm dia

20

-

-

... More
40 mm dia

15

-

-

... More
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion.(i) Single socketed pipes. 160 mm diameter

360

-

-

... More
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion. Single tee with door 160x160x160 mm

20

-

-

... More
Bend 87.5° 160 mm bend

36

-

-

... More
Making Khurras size 45 x 45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1m x 1m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement: 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete.

18

-

-

... More
Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design : 150 x 100 mm size P type. With common burnt clay F.P.S. (non modular) bricks of class designation 7.5

30

-

-

... More
Supplying, installation, testing and commissioning of ElectricdrivenMainFirePumpsuitableforautomatic operationandconsistingof following, complete inall respects, as required : (a)Horizontal type, multistage, centrifugal, split casing pumpofcast ironbody&bronzeimpellerwithstainless steel shaft, mechanical seal conforming to IS 1520. (b)Suitable HP Squirrel cage induction motor, TEFC, synchronousspeed1500RPM, suitable foroperation on415volts, 3phase50Hz, ACsupplywith IP55 protection forenclosure, horizontal footmounted type with Class-'F' insulation, conforming to IS-325. (c)M.S. fabricatedCommonbaseplate,coupling,coupling guard, foundation bolts etc. as required. (d)Suitable cement concrete foundation duly plastered2280 lpm at 70 m Head TYPE OF PUMP = Centrifugal Pump Capacity / Discharge = 2400 lpm outlet Head = 70 mwc

1

-

-

... More
Supplying, installation, testing and commissioning of ElectricdrivenMainFirePumpsuitableforautomatic operationandconsistingof following, complete inall respects, as required : (a)Horizontal type, multistage, centrifugal, split casing pumpofcast ironbody&bronzeimpellerwithstainless steel shaft, mechanical seal conforming to IS 1520. (b)Suitable HP Squirrel cage induction motor, TEFC, synchronousspeed1500RPM, suitable foroperation on415volts, 3phase50Hz, ACsupplywith IP55 protection forenclosure, horizontal footmounted type with Class-'F' insulation, conforming to IS-325. (c)M.S. fabricatedCommonbaseplate,coupling,coupling guard, foundation bolts etc. as required. (d)Suitable cement concrete foundation duly plastered2280 lpm at 70 m Head TYPE OF PUMP = Centrifugal Pump Capacity / Discharge = 2400 lpm outlet Head = 70 mwc

1

-

-

... More
Supplying, installation, testing and commissioning of diesel engine driven main fire pump suitable for automatic operation and consisting of following, complete inall respects,asrequired : (DieselDriven Pump) Horizontal type,multistage,centrifugalpumpofcastof ironbodyandbronzeimpellerwithstainlesssteelshaft, mechanical seal conforming to IS 1520.SuitableHP, 1500RPMwater cooledwith radiator, diesel engine conforming to relevant IS standard completewithautostartingmechanism, 12 /24volts electric startingequipment, diesel tank, exhaust pipe extendedupto10moutsidepumphousedulyinsulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stopsolenoidforautostopintheeventof faultwithaudioindications,paintedwithpostofficered colour etc. as required.2280 lpm at 70 m Head Pump Capacity / Discharge = 2280 lpm outlet Head = 70 mwc

1

-

-

... More
Oil Tank Supplying, fixing and commissioning 500 ltrs. capacity including first fill of 500 ltrs high speed diesel oil in 16 SWG MS steel oil tank with manhole cover, glass gauge, inlet and outlet connections with gate valves, drain plug, GI piping between tank and engine vent pipe with wire mesh etc. duly painted and mounted on suitable MS angle staging to maintain gravity flow of oil. make: Kirloskar/Grundfos/Equivalent.

1

-

-

... More
JOCKEY PUMP 3 Supplying, installation, testing and commissioning of electric driven pressurisation pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Jockey Pump) Horizontal type,multistage, centrifugal pump of cast ironbodyandbronzeimpellerwithstainlesssteelshaft, mechanical seal conforming to IS : 1520. SuitableHPsquirell cage inductionmotorTEFCtype suitable for operationon415volts, 3phase 50Hz ACsupplywithIP55classofprotectionforenclosure, horizontal footmounted typewithClass-'F' insulation, conforming to IS : 325. M.S.fabricatedCommonbaseplate,coupling,coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation duly plastered and with anti vibration pads..180 lpm at 70 m Head TYPE OF PUMP = Centrifugal Pump Capacity / Discharge = 180 lpm outlet Head = 70 mwc

2

-

-

... More
FIRE PUMPS PANEL & ELECTRICAL WORK Fire Pumps Panel "Incomings 800A, 50kA 4 Pole MCCB, Ics=100% Icu Rating Digital Voltmeter 0-500V with selector switch Ammeter (0-800 A) with selector swtich & CTs etc. LED type RYB phase indicating lamps, ON, OFF, trip indicating lamps Set of Copper Bus Bar 1000Amps Outgoing ( Note : All outgoing feeders for pumps should have digital Ammeter with selector switches, and LED type ON, OFF, trip indicating lamps) Main Fire Pump 250 Amp, 50kA TPN MCCB, Ics=100% Icu, with fully automatic Star/Delta starter suitable for 100 hp pump with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation. - 2 sets " "Jockey Pump 125 Amp, 50kA TPN MCCB, Ics=100% Icu, with Suitable HP fully automatic Star/Delta starter with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation. - 2 sets DIESEL ENGINE CONTROL Control for diesel engine comprising -Automatic/Manual selctor switch & 3 attempts starting device, timers and relays as required, push buttons, start/stop in manual mode Indicating lamp for high/ Low Lub. Oil pressure, High Water Temp and Engine on indication Battery charger suitbale for 12V/24 V DC with boost and trickle selector switch, 0-30 V DC volt meter, and 0-20 A DC Ammeter"

1

-

-

... More
Supplying, storing, laying 1.1 KV grade PVC/ XLPE insulated aluminium/ copper conductor armoured/ Unarmoured cables on existing cable tray, in trenches or directly buried in ground. 3c x 150 Sq.mm XLPE Cu Arm cable.

90

-

-

... More
4c x 4 Sq.mm XLPE Cu Arm cable.

90

-

-

... More
4c x 6 Sq.mm XLPE Cu Arm cable.

52

-

-

... More
Supplying all the materials, cutting, peeling terminating and connecting cable with brass cable gland and crimped aluminium lugs in respective DBs switches etc. 3c x 150 Sq.mm XLPE Cu Arm cable.

6

-

-

... More
4c x 4 Sq.mm XLPE Cu Arm cable.

6

-

-

... More
4c x 6 Sq.mm XLPE Cu Arm cable.

2

-

-

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 150 mm width X 50 mm depth X 1.6 mm thickness

30

-

-

... More
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.

1

-

-

... More
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.

100

-

-

... More
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 80 mm dia.

40

-

-

... More
100 mm dia.

65

-

-

... More
150 mm dia.

5

-

-

... More
200 mm dia. (Header)(Wall Thickness 6.3mm)

15

-

-

... More
250 mm dia. (Header)(Wall Thickness 6.3mm)

10

-

-

... More
Butterfly valve Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : 80 mm dia.

3

-

-

... More
100 mm dia.

3

-

-

... More
150 mm dia.

3

-

-

... More
200 mm dia.

5

-

-

... More
250 mm dia.

1

-

-

... More
Non Return Valves Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required : 80 mm dia.

3

-

-

... More
150 mm dia.

3

-

-

... More
200 mm dia.

1

-

-

... More
Y-Strainer Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange. 100 mm dia.

3

-

-

... More
200 mm dia.

3

-

-

... More
Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required : 250 mm dia.

1

-

-

... More
Providing & fixing double flanged flexicon rubber expansion joint (suitable for system test pressure) of standard length as per manufacturers specs including rubber gaskets, flanges, nuts, bolts and washers complete as required. 80 mm dia.

3

-

-

... More
100 mm dia.

3

-

-

... More
150 mm dia.

3

-

-

... More
200 mm dia.

3

-

-

... More
Providing & fixing flow switch in following sizes M.S. pipe including connection etc as required. 100mm dia

10

-

-

... More
Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required.

8

-

-

... More
Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade as required.

5

-

-

... More
Providing and fixing inspectors test assembly complete with test valve, sight glass sectional drain valve, union with corrosion resistant orifice all complete strictly as per drawing. (1 no. for hydrant + 1 no. for sprinkler) Note: Suitable for test pressure of 1.5 time of rated pressure. PN 16 (16 Bar / 16 kg/sq.cm / 160 m of H2O / 232 psi)

1

-

-

... More
MS Class ‘C’ diesel engine exhaust pipe (including all fittings, silencer, clamps, steel support) of 6'' dia for the engine. The Exhuast pipe for Disel engine of 150mm dia M.S. Medium grade of 80kg/sq.cm with mineral wool insulation with aluminum sheet

25

-

-

... More
Providing, fixing, testing & commissioning of MS air cushion tank on top of each riser fabricated from 6mm thick MS plate, 200 mm in diameter and 1.2 m in height with dished ends fabricated from 8mm thick MS plate with Air release valve with stop cock, flanged inlet connection and drain arrangement with 25mm dia valve, pressure gauge with gun metal stop cock complete with all accessories as required and conforming to IS 4736-1968.

1

-

-

... More
Providing, laying, testing & commissioning of 'B' class heavy duty G.I. pipe conforming to IS 1239 including welding, fittings like elbows, tees, flanges, tapers, nuts, bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 80 mm dia

50

-

-

... More
100 mm dia

60

-

-

... More
150 mm dia

200

-

-

... More
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : Note: Suitable for test pressure of 1.5 time of rated pressure. 80 mm dia

14

-

-

... More
Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required : 80 mm dia

12

-

-

... More
Supplying and fixing Single headed external yard hydrant valve with 1 No. 63 mm dia instantaneous FM Gunmetal/Stainless Steel coupling and cast iron wheel, ISI marked, conforming to IS 5290 (type A) with blank Gunmetal/Stainless Steel cap and chain as required : Single headed Stainless steel

6

-

-

... More
Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket. 30 m

6

-

-

... More
Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required : Gun Metal

12

-

-

... More
Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required : Gun metal

12

-

-

... More
Providing and Fixing rising Branch pipe Nozzle with complete as required. with brass Material

12

-

-

... More
Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required : Single headed Stainless steel

14

-

-

... More
Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket. 30 m

14

-

-

... More
Providing and fixing 5 mm thick glass door (with M.S. frame) of size 1.5 m x 0.9 m with center opening for fire hose cabinet. Suitably marked on the outside with the letters "FIRE HOSE" including locking arrangement. All M.S. work to be in Red P.O. colour over appropriate primer. The above item is only for masonary fire station.

14

-

-

... More
Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required : Gun Metal

28

-

-

... More
Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required : Gun metal

28

-

-

... More
Providing and Fixing rising Branch pipe Nozzle with complete as required. with S.S. Material

28

-

-

... More
Swinging type First hose reel Drum with Assemble Providing & fixing swinging type First Aid hose reel in red colour drum with 30 mts long and 20 mm dia heavy duty rubber water hose, 20 mm dia globe valve stop cock, terminating with G.M. coupling & nozzle of 6mm outlet with shut off valve confirming to IS 8090 - 1976 complete with MS socket for tap-off, drum and brackets (including painting) for fixing on wall with anchor fastner, bolts & nuts conforming to IS:884-1969 complete as required. with ss coupling & nozzle

14

-

-

... More
Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required : 4 way - 150 mm dia M.S. Pipe

1

-

-

... More
Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required : 2 way-100 mm dia M.S. Pipe

1

-

-

... More
Providing, laying, testing & commissioning of 'B' class heavy duty G.I. pipe conforming to IS 1239 including welding, fittings like elbows, tees, flanges, tapers, nuts, bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 25 mm dia

700

-

-

... More
32 mm dia

100

-

-

... More
40 mm dia

110

-

-

... More
50 mm dia

100

-

-

... More
65 mm dia

170

-

-

... More
80 mm dia

80

-

-

... More
100 mm dia

30

-

-

... More
150 mm dia

20

-

-

... More
Providing and fixing forged S.S. material ball valve with forged brass ball of the following size including providing necessary union / flange. Note: Suitable for test pressure of 1.5 time of rated pressure. PN 16 (16 Bar / 16 kg/sq.cm / 160 m of H2O / 232 psi) 50 mm dia

14

-

-

... More
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : 80 mm dia

12

-

-

... More
100 mm dia

2

-

-

... More
Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required : 80 mm dia

10

-

-

... More
100 mm dia

2

-

-

... More
Providing and Fixing electrically operated water flow switches (Vane type) including tamper switch and accessories, complete with tap off socket arrangement as required, with potential free contact with 2 Nos. NONC. Note: Suitable for test pressure of 1.5 time of rated pressure. PN 16 (16 Bar / 16 kg/sq.cm / 160 m of H2O / 232 psi) 80 mm dia

12

-

-

... More
Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories : Pendent Sprinkler

290

-

-

... More
Horizontal side wall sprinkler

110

-

-

... More
Supplying, installation, testing & commissioning of sprinkler flexible pipe (UL Listed) of stainless steel complete with 15 NPT on reducer thread with maximum working pressure of 175 PSI test pressure of 875 PSI (Burst) with branch line (Inlet) 25mm NPT male thread to sprinkler head (Outlet) 15mm NPT female thread with reducer, nipple, 2 side brackets, center bracket, stockbar of following sizes complete as required. 1500 mm long

200

-

-

... More
Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade as required.

8

-

-

... More
Providing and fixing inspectors test assembly complete with a corrosion resistant bronze quarter turn ball test valve,cast iron body with dual glass lenses mounted in plated steel sight glass sectional drain valve, union with a chrome plated, corrosion resistant bronze quarter turn ball valve with a 5.6K smooth bore test orifice. All of the pipe thread connections are assembled with a Teflon based pipe joint sealant and each assembly tested to 350 psi (24,1 bar). (For sprinkler branch pipe) 25mm dia

8

-

-

... More
Supply, installation, testing and commissioning of following types of extinguisher with provision of wall bracket (fixed with anchor fastner). Dry Chemical Power Type (ABC) Portable Dry Chemical Power Type Fire Extinguisher with Gun Metal cap and nozzle and complete in all respects including initial fill and wall suspension bracket 6 kg.

26

-

-

... More
Carbon-di-oxide / C02 type ISI marked (IS:2878) portable fire extinguisher, Carbon-di-oxide type Flat base including valve, discharge hose of not less than 10 mm dia, 1 M long and complete in all respects including initial fill with CO2 gas confirming to IS:307-1966 filled to a filling rate of not more than 0.667 and wall suspension bracket. Capacity 5 Kg

4

-

-

... More
Supplying and installing at approved location approved make fire buckets of 24 gauge galvanized steel sheet, standard 9 litre capacity and of round bottom shape, painted white inside and red outside and black on the bottom, inscribed with letters “FIRE” in black and gold. Cost shall be inclusive of providing MS stand duly painted over a coat of primer.

10

-

-

... More
Supplying installation testing and commissioning of Grid interactive roof top solar photo voltaic power generation system including all the required accessories like Solar PV module, Grid Tie invertor, arrey junction box, cabling & wiring, earthing, surge protection device, FRLSame structure for mounting of solar panel. The cell shall be poly crystaline silicon cells of 6 inch each and module efficiency shall be more than 17%. Solar module shall have linear output warranty with degradation not exceeding 0.7% FRLSom 2nd Year onwards. Minimum 80% power output must be assured at end of 25 years. The FRLSont glass of solar module shall be low iron tempered glass ARC type. Termination box shall be Thermo-plastic, IP 67 or better, UV resistant with built-in-bypass. The nominal power of a single PV module shall be minimum 325 Wp or higher. Positive power tolerance modules only to be used. RF identification tag for each solar module shall be provided inside the module and must be able to withstand environmental conding following incoming and outgoing Air Circuit Breakers, MCCB as per the drawing and specification. Fault level shall be 50 KA. Each incoming / outgoing breaker shall have microproce

50

-

-

... More
Supplying & fixing of auditorium chair with sliding mechanism complete in all respects as per direction given by engineer in charge.

214

-

-

... More
Supplying & fixing of wool carpet for auditorium walls & floor with cartage complete in all respects as per direction given by engineer in charge.

870.72

-

-

... More
Supplying & fixing of SS 304 sheets over column with cartage complete in all respects as per direction given by engineer in charge.

1457.04

-

-

... More
Supplying & fixing of chicken mesh jali complete in all respects as per direction given by engineer in charge.

2810.27

-

-

... More
Supply & installation of smart booths for mobile charging complete in all respects including all labor & installation.

40

-

-

... More
Supply & fixing of MOSFI Drop Arm Barrier (Boom Barrier), As Per MHA QR for Drop Arm Barrier (Boom Barrier),issued by MHA Vide No.- P-63013/11/2013-Ord/BSF/MHA/Prov.I /870 dated 24th Sept 2015 complete in all respects including all labor & installation.

2

-

-

... More
Supply of flower pots complete in all respects including all labor & installation.

250

-

-

... More
Supply & fixing of acrylic letters on shop hordings complete in all respects including all labor & installation.

566.07

-

-

... More
Supply & fixing of audio video & acoustic system for audotirum complete in all respects including all labor & installation.

1

-

-

... More
Supply & fixing of backround music/pa system for mall complete in all respects including all labor & installation.

1

-

-

... More
Supply & fixing of HEAT SEALING, INSTALLATION AND TESTING OF TENSILE MEMBRANE STRUCTURE OF MEHLER VALMEX MEHATOP FR -900 GSM TYPE-II (BOTH SIDE PVDF LACQUER)/SERGE FERRARI FLEXLIGHT ADVANCED 902 S2 WITH MS STRUCTURAL SUPPLY FABRICATION AND ERECTION complete in all respects including all labor & installation.

1

-

-

... More
Supply & fixing of toilet partitions(BESCO BACCHUS MODEL WITH BACCHUS ACCESSORIES) complete in all respects including all labor & installation.

1

-

-

... More
Supply & fixing of X-RAY baggage scanner system complete in all respects including all labor & installation.

4

-

-

... More
Supply & fixing of door frame metal detector complete in all respects including all labor & installation.

4

-

-

... More
Supply & fixing of mall inner & outer LED screens waterproof complete in all respects including all labor & installation.

275

-

-

... More
Working on italian marble for inlay work including all labor & material as per architectural drawings complete in all respects including all labor & installation.

200

-

-

... More
Providing and laying cobbel stone mix patterns galaxy white & steel grey flooring in linear as well as curvilinear portions all complete as per the architectural drawings over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) all complete as specified and as directed by the Engineer-in-Charge

560.88

-

-

... More
Providing & fixing of musical fountain machinery as per the design with all its accessories like pipe, pumps, panels, etc. complete in all respects including all labor & as per direction given by engineer in charge.

1

-

-

... More
Supply & installation of pump of complete in all respects as per direction given by engineer in charge.

6

-

-

... More
Supply & installation of pump of 0.5 hp complete in all respects as per direction given by engineer in charge.

2

-

-

... More
Supply & installation of 60KLD STP Machinery complete in all respects as per direction given by engineer in charge.

1

-

-

... More
Supply of AC 230/250 volts, 50 HZ energy efficient ceiling fan with standard down rod, blades, 3 nos. caps Model-ES 50 (1200 mm Sweep) etc. complete in all aspects as per direction of Engineer in Charge 1200 mm sweep

3

-

-

... More
SUPPLY OF LED Glass Bulb B22, 15 W ,6000k /4000k/3000K ,230/250 Volt,50 HZ ETC, complete in all aspects as per direction of Engineer in Charge.

6

-

-

... More
Supply and fixing of LED Tube light 1200mm 20W 865 T8 IP20 ,Lumen Output-1600 , 3000, 4000, 6500K ceiling mounted LED batten (E-LITE LED TRIYCA) , extruded aluminium heat sink provided for efficient heat deissipation 7& integrated electronic driver. ( 1x20 W LED Double 6500K) complet in all aspects as per direction of Engineer in charge.

3

-

-

... More
Borewell

1

-

-

... More
Car Parking System

1

-

-

... More
Escalators (11No. 1000mm step width)

11

-

-

... More
Lift (Passenger)

3

-

-

... More
Lift (GOODS)

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.