Central Building Research Institute Tender
View complete overview of Uttarakhand CBRI Tender
Central Building Research Institute - CBRI Tender
Civil And Construction
Building Construction
Eprocure
Opening Date31 May 2022
Closing Date13 Jun 2022
Tender Amount₹ 67,86,653 This is an estimated amount, exact amount may vary.
Costs
EMD
₹ 1,35,800Document Cost
₹ 1,180Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2022_CSIR_117616_1Bid Award Id
ViewTender No
193(606)EST/2022-23Tender Authority
Central Building Research Institute ViewPurchaser Address
-Website
http://https://www.csir.res.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge.
1
-
-
Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.In cement mortar
4
-
-
Providing Unskilled manpower for shifting of various old testing models and materials from construction site to specified space in the institute as per direction of Engineer-in-charge
12
-
-
Providing skilled manpower for shifting of various items, furneture,old testing models and materials from construction site to specified space in the institute as per direction of Engineer-in-charge
6
-
-
Providing Tractor trolly for shifting of malba, debrise, soil, various old testing models and materials from construction site to outside of institute and out site area of nagar nigum Roorkee including loading unloading complete work in all respect as per direction of Engineer-in-charge.
18
-
-
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil.
264
-
-
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
158
-
-
Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
325
-
-
Supplying chemical emulsion in sealed containers including delivery as specified.Chlorpyriphos/ Lindane emulsifiable concentrate of 20%
40
-
-
Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) :Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor:With Chlorpyriphos/Lindane E.C. 20% with 1% concentration
300
-
-
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size)
37
-
-
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)
2
-
-
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone - III) : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
78
-
-
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size)
33
-
-
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size)
18
-
-
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).
24
-
-
Centering and shuttering including strutting, propping etc. and removal of form for :
-
-
-
Foundations, footings, bases of columns, etc. for mass concrete
73
-
-
Lintels, beams, plinth beams, girders, bressumers and cantilevers
193
-
-
Columns, Pillars, Piers, Abutments, Posts and Struts
198
-
-
Weather shade, Chajjas, corbels etc., including edges
30
-
-
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Cold twisted bars
8831
-
-
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand)
16
-
-
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:6 (1 cement : 6 coarse sand)
91
-
-
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.Cement mortar 1:4 (1 cement :4 coarse sand)
23
-
-
Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x1.25 mm M.S. laths with 1.25 mm thick top cover
25
-
-
Providing and fixing ball bearing for rolling shutters.
4
-
-
Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment).Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
1022
-
-
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
744
-
-
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.40 mm thick with 20 mm nominal size stone aggregate
300
-
-
Providing and fixing glass strips in joints of terrazo/ cement concrete floors.40 mm wide and 4 mm thick
360
-
-
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineerin- charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
378
-
-
Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete :Ridges plain (500 - 600mm)
27
-
-
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
10956
-
-
Providing and fixing bolts including nuts and washers complete.
82
-
-
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :One or more coats on old work
320
-
-
12 mm cement plaster of mix :1:6 (1 cement: 6 fine sand)
397
-
-
15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand)
448
-
-
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :Water thinnable cement primer
397
-
-
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
397
-
-
Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two or more coats on new work
397
-
-
Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade:New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
591
-
-
Smooth finishing of the exposed surface of R.C.C. work with 6 mm thick cement mortar 1:3 (1 Cement : 3 fine sand).
228
-
-
Wiring for light Point/ fan point/ exhaust fan point with 1.5 sq..mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit with modular switch of Havell’s/ Modular Legrand Mosaic Anchor ROMA make ISI marked, modular plate suitable G.I Box and earthing the point with 1.5 sq mm FRLS PVC insulated copper conductor single core cable of Polycab/ Havell’s/ KEI/ RR and Phenolex make including ceiling rose / holder as required.
48
-
-
Wiring for circuit /sub-main wiring along with earth wire with the following size of FRLS PVC Insulated copper conductor, single core cable of Polycab/ Havell’s/ KEI/ RR/ and Phenolex make 1100 V grade ISI marked in surface/ recessed steel conduit as required
-
-
-
2 x 2.5 sq.mm + 1 x 2.5 sq.mm earth wire
120
-
-
2 x 4 sq.mm + 1 x 4 sq.mm earth wire
160
-
-
4 core 4 sq.mm + 2 x 4 sq.mm earth wire
15
-
-
4 core 10 sq.mm + 2 x 6 sq.mm earth wire
150
-
-
Supplying and fixing 4 modules (75mmX75mm) G I box along with modular base and cover plate for modular switches in recess etc. as required.
8
-
-
Supplying and fixing 6 modules (200mmX75mm) G I box along with modular base and cover plate for modular switches in recess etc. as required.
3
-
-
Supplying and fixing 12 modules (200mmX150mm) G I box along with modular base and cover plate for modular switches in recess etc. as required.
4
-
-
Supplying and fixing modular blanking plate on the existing modular plate and switch box excluding modular plate etc. as required.
3
-
-
Supplying and fixing 5/6 A modular type switch on the existing Modular plate and switch box including connections but excluding modular plate etc. as required.
48
-
-
Supplying and fixing suitable size G.I Box with modular plate and cover in front on surface or in recess, including P/F 6 pin 5 / 6 & 15 / 16 A modular socket outlet and 15/16 A modular switch, connections etc as required.
7
-
-
Supplying and fixing 30 / 32 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal inclosed plug top along with 30A “C” curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
5
-
-
Supplying and fixing factory wired Havells make stout LED light battens of 40 watt including suitable size M S patti Cat. No. 1200BS40WLED857SPCWH or its equivalent make of Bajaj / Phillips complete in all respect as required directed by engineer incharge.
14
-
-
Supplying and fixing enviornmently friendly, new generation asthetically designed robust high bay suitable for ceiling mounting with system efficacy up to 150 lm/W or its equivalent make of Bajaj/Philips make complete in all respect as required and directed by engineer-in-charge.
10
-
-
Supply and Fixing LED street light fixture of new generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing and high power with high LED as lighting source and lens embedded PC cover having top opening separate driver compartment with IP66 protection and impact reistance of IK07 with 10 KV built – in Surge protection device of Havells make 90 watt, 230 V odering code ENDURAPEARLPLUSS L90 W LED 757PASYTOPCASTHO or its equivlant make of Bajaj/ Philips complete as required.
3
-
-
Supplying and fixing of 32 mm dia X 2.00 metres long G I pipe (medium class) bracket for mounting of havells make 90 watt 230 LED street light fitting on polel including bending the pipe to the required shape, 2 nos. 40mm X 3mm flat iron clamp with nuts, bolts and washers; wiring with 2.5 sq. mm wp/pvc wire and painting the flat iron with primer and finish paint etc. as required.
3
-
-
Supplying and fixing of 400 mm sweep oscillating type wall mounting fan of Crompton (SDX)/Havells (Platina) make complete in all respect as required and directed by engineer incharge.
6
-
-
Supplying and fixing of exhaust fan 450 mm sweep Havells make with model variant Hi -speed metallic body or its equivlant make of Cromption / bajaj/ Philips in all respect as required and directed by engineer incharge.
15
-
-
Providing and fixing 200 A, 16 KA, TPMCB rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.
1
-
-
Supplying and fixing of 12 way (4 + 36), Double door TPN MCB distribution board 415 V on surface/ recess, complete with tinned copper bus bar, common neutral link, earth bar, din bar ditachable gland plate interconnections, Phosphatised and powder painted including earthing etc.as required. (But without MCB /RCCB / Isolation) of Havells make or its equivalent of Legrand/ ABB/ L&T and Sciemense Make
1
-
-
Supplying for laying in existing trench PVC insulated and PVC sheathed /XLPE armoured heavy duty 1.1 KV grade Grandle / Havells / Poly-cab make ISI marked heavy duty, aluminium conductor electric cable as per latest specification , including connection testing etc. complete in all respect as required and directed by engineer incharge: 3.5 core X 95 sq.mm.
45
-
-
Supplying and making end termination indoor end termination with brass compression gland and aluminium lugs for 3.5 core 95 sq. mm (38mm) size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required
2
-
-
Supplying and fixing 40 A four pole, 415 V,isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
5
-
-
Supplying and fixing single pole 5- 32A rating 240/415 V, 10 KA, C series MCB suitable for inductive loads in the existing MCB DB complete with connection, testing and commissioning etc. as required.
21
-
-
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
2
-
-
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) as required.
30
-
-
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
105
-
-