Central Building Research Institute Tender

View complete overview of Uttarakhand CBRI Tender

Central Building Research Institute - CBRI Tender

Works
Electrical and Electronics
Eprocure
Opening Date29 Oct 2022
Closing Date8 Nov 2022
Tender Amount₹ 23,65,462 
This is an estimated amount, exact amount may vary.
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
b) 2x4 Sq mm + 1x4 Sq mm earth wire

200

-

-

... More
c) 2x6 Sq mm + 1x6 Sq mm earth wire

100

-

-

... More
S/F metal box of 150mm x 75 mmx 60mm deep(nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including P/F 3 pin 5/6 amps socket out let & 5/6 amps piano type switch ,connection , painting etc as required.(for CBRI Institute area)

10

-

-

... More
S/F metal box of 180mm x 100 mmx 60mm deep(nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including P/F 6 pin 5/6 & 15/16 amps socket out let & 15/16 amps piano type switch ,connection , painting etc as required.(for CBRI Institute area)

15

-

-

... More
Excavating trenches of required width for taking out existing cable from the trench upto 1.5 m depth including getting out the excavated soil, relaying the cable in the same trench with existing protective covering including returning the soil as required in layers not exceeding 20cm in depth including consolidating each layer by ramming, watering etc. and disposing surplus excavated soil as directed with in a lead of 50m,dressing of sides all as required for pipe, cable etc not exceeding 80mmdia.(for CBRI Institute area)

200

-

-

... More
Overhauling of ceiling fan upto 1400mm/exhaust fan upto 450mm/table fan/padestal fan/ wall fan of any size including supply and replacement of ball bearing/bush, capacitor, split pin, rubber reel, shaft, nut & bolts, 2x1.5 sqmm copper connecting wire, cleaning, varnishing, revolving attachment and step regulator with resistance of wall fans and pedestal fans etc complete in all respect as required.

15

-

-

... More
Rewinding of ceiling fan upto 1400mm/exhaust fan upto 450mm/table fan/padestal fan/ wall fan of any size with super enameled copper wire, insulating material, varnishing, backing etc complete in all respect as required.(for CBRI Institute area)

15

-

-

... More
Providing of skilled manpower in electrical trade for attending day to day complaints of electrical maintenance work for repair and replacement of all electrical wiring, accessories in non working electrical fittings and fixtures( such as main boards, fans, geysers, heaters, blowers, switches, sockets, light fittings, motors, starters, street lights, energy meters in residential and non residential buildings, underground and overhead line distribution network including service mains, DG set operation including filling of diesel etc.) and all other electrical work as assigned by site incharge on all the 365 days of year. Services are also required during night on all days. (for CBRI Institute area) , (Man power may be engaged in CBRI Colony electrical maintenance work also as per requirement. At least two labor should have experience to work in electrical substation) (8 working hours shall be treated as one manday).

1565

-

-

... More
Wiring for light point / fan point/exhaust fan point/call bell point with 1.5 Sq mm FRLS PVC insulated copper conductor single core cable in surface/recessed steel conduit with piano type switch ,phenolic laminated sheet , suitable size MS box & earthing the point with 1.5 Sq mm FR LS PVC insulated copper conductor single core cable of Polycab/Havells/KEI cables/RR Kables/Phenolex make ISI marked for following Group point including ceiling rose/lamp holder as required complete.(for CBRI quarters and Colony)

-

-

-

... More
Group A

30

-

-

... More
Group B

10

-

-

... More
Group C

10

-

-

... More
Wiring for circuit/submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor single core cable of Polycab/Havells/KEI cables/RR Kables/Phenolex make ISI marked 1100 volts grade in surface / recessed steel conduit as required.(for CBRI quarters and Colony)

-

-

-

... More
a) 2x2.5 Sq mm + 1x2.5 Sq mm earth wire

150

-

-

... More
b) 2x4 Sq mm + 1x4 Sq mm earth wire

150

-

-

... More
c) 2x6 Sq mm + 1x6 Sq mm earth wire

50

-

-

... More
S/F metal box of 150mm x 75 mmx 60mm deep(nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including P/F 3 pin 5/6 amps socket out let & 5/6 amps piano type switch ,connection , painting etc as required.(for CBRI quarters and Colony)

20

-

-

... More
S/F metal box of 180mm x 100 mmx 60mm deep(nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including P/F 6 pin 5/6 & 15/16 amps socket out let & 15/16 amps piano type switch ,connection , painting etc as required.(for CBRI quarters and Colony)

20

-

-

... More
Excavating trenches of required width for taking out existing cable from the trench upto 1.5 m depth including getting out the excavated soil, relaying the cable in the same trench with existing protective covering including returning the soil as required in layers not exceeding 20cm in depth including consolidating each layer by ramming, watering etc. and disposing surplus excavated soil as directed with in a lead of 50m,dressing of sides all as required for pipe, cable etc not exceeding 80mm dia.(for CBRI quarters and Colony)

200

-

-

... More
Overhauling of ceiling fan upto 1400mm/exhaust fan upto 450mm/table fan/padestal fan/ wall fan of any size including supply and replacement of ball bearing/bush, capacitor, split pin, rubber reel, shaft, nut & bolts, 2x1.5 sqmm copper connecting wire, cleaning, varnishing, revolving attachment and step regulator with resistance of wall fans and pedestal fans etc complete in all respect as required. (for CBRI quarters and Colony)

30

-

-

... More
Rewinding of ceiling fan upto 1400mm/exhaust fan upto 450mm/table fan/padestal fan/ wall fan of any size with super enameled copper wire, insulating material, varnishing, backing etc complete in all respect as required.(for CBRI quarters and Colony)

30

-

-

... More
Providing services of skilled manpower in electrical trade for attending day to day complaints of electrical maintenance work for repair and replacement of all electrical wiring , accessories in non working electrical fittings and fixtures ( such as main boards, fans, geysers, heaters, blowers, switches, sockets, light fittings, motors, starters, street lights, energy meters in residential and non residential buildings, underground and overhead line distribution network including service mains) and all other electrical work as assigned by site incharge on all the 365 days of year. (for CBRI quarters and Colony)(Man power may be engaged in CBRI Institute electrical maintenance work also as per requirement. At least two labor should have experience to work in electrical substation) (8 working hours shall be treated as one manday)

800

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.