Central Building Research Institute Tender

View complete overview of Uttarakhand CBRI Tender

Central Building Research Institute - CBRI Tender

Works
Electrical Generators And Transformers
Electrical and Electronics
Eprocure
Opening Date17 Nov 2023
Closing Date7 Dec 2023
Tender AmountRefer Documents 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Isolator Switch of 11kV, 630A, 21kA for 3 sec Outdoor, SF6 Gas Insulated switchgear with 01 nos direct cable module and 01 no. Manually operated Vacuum Circuit Breaker.

1

-

-

... More
B. The equipment shall be totally enclosed in MS sheet enclosed cubical, dust and vermin proof with necessary isolation arrangement at the incomer side. Each panel shall be easily extensible on either side and should be complete with necessary internal copper connections, small wiring, L.T. fuses and supporting framework with bolts to secure it to the floor. Each panel shall be provided with space heater, door switch with lamps and 15 - Ampere power receptacle.

-

-

-

... More
3. Bus Bar Specifications: i.2000 A TPN electrolytic Al bus bar with heat shrinkable insulation sleeve.

-

-

-

... More
Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long ,G.I. tube ,having single prong at top with 85 mm dia 6mm thick G.I. base plate including holes etc. Complete as required.

1

-

-

... More
Providing and laying G.I. tape 32mm*6mm from earth electrode directly in ground as required.

20

-

-

... More
1.Electrical distribution panel Specifications: i. Panels shall be suitable for 415V, 3 phase, 4 wire, 50 HZ supply system. ii. 2 No. earthing terminals shall be provided for distribution panel. iii. Panel, fabricated out of 14 gaugeCRCA sheet steel in cubicle. Formation and compartment alized free standing floor mounted dust and vermin proof. iv. 3 mm thick cable gland plates shall be provided on top as well as at the bottom of the panel. v. Panels shall be treated with all anticorrosive process before powder coating. vi. Indicator lights shall be provided to mention status for all compartments. vii. All bus bar section/ backside panels shall have pad locking facility and hinged type door. viii. Wiring and supply for installation of space heater, humidistat and control MCB’sshall be provided for all vertical sections. ix. Incoming breakers shall have suitable provision for busduct connection. x. Approval shall be taken on final design before fabrication.

-

-

-

... More
Providing and fixing G.I. tape 20mm*3mm thick on parapet or surface of wall for lighting conductor complete as required .(For vertical run )

20

-

-

... More
Supplying and Laying HT 185 sq mm 3 core 11KV Alluminium conductor

50

-

-

... More
Earthing with copper earth plate 600mm*600mm*3mm thick including accessories ,and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc.with charcoal /coke and salt as required.

7

-

-

... More
Construction and civil works for the installation of Transformer (complete in all respect as directed by Engineer In-charge)

1

-

-

... More
Excavating trenches of required width upto 1.5 m depth including getting out the excavated soil, laying the cable in the same trench with protective covering including returning the soil as required in layers not exceeding 20cm in depth including consolidating each layer by ramming, watering etc. and disposing surplus excavated soil as directed with in a lead of 50m,dressing of sides all as required for pipe, cable etc not exceeding 400mm dia.

250

-

-

... More
2. Electrical distribution panel Incomer Specifications Incoming Air Circuit Breaker from 1000 kVA Transformer of 2000 amps, 4 pole,65KA breaking capacity, electrically operated manually draw out type air circuit breakerwith microprocessor release unit, for short circuit, over current, under Voltage and earth faultprotection with adjustable setting consisting of: i. Digital load manager/Electronic Meter of accuracy class-I, or equivalent. ii.Phase indicating light shall be protected by suitable rate MCB’s iii.Breaker ON / OFF / TRIP indicating lights with control MCB’s. - 1 Set iv.240 V DC Shunt trip coil. - 1 Set v.240 V under voltage release. - 1 Set vi.Breaker control switch - 1 Set vii.Emergency stop push button. viii.Selector switch for Auto / Manual / Test ix.Five push buttons – start, stop, reset, test and accept x.Phase loss+PhaseSequence+Phase Assymetry+UV+OV+3 Phase interruption relay.

-

-

-

... More
Jointing copper /G.I. tape (with another copper/G I tape, base of the finial or any other metallic object) by riveting /nut boiting /sweating and soldering etc as required.

1

-

-

... More
HT Switchgear Specifications : Indoor type 11KV VCB Switchgear Panel with 1 incoming panel and 2 outgoing panel with each outgoing panel consisting of following specifications:

-

-

-

... More
Supplying and Laying LT 240 sq mm 4 core 11 KV Alluminium conductor cable 200 meter.

200

-

-

... More
A. The instrument panel and instrument transformers shall be complete in all respect consisting of: i. Control relay panel having Trip circuit supervision relay, Restricted Earth Fault relay with CT's, Master Trip circuit relay, over current & Earth Fault IDMT relay ii. Cast resin CTs of dual ratio 40– 80 / 5 Amps CL:1, 5P10, 15 VA. iii. Cast resin drawout type PTs 11 kV / √3 / 110 √3, class 1, 100 VA. iv. Breaker control switch, v. Set of ON/OFF indicating lamps. vi. Clear lamp for trip circuit health supply. vii. Digital electronic ammeter with selector switch. viii. Digital electronic Voltmeter with selector switch. ix. Digital electronic Trivector meter.

-

-

-

... More
Electrical distribution panel consisting of 1 incomer, 3 outgoing and 1 bus coupler with following detailed specifications:

-

-

-

... More
Transformer Specifications: 1000KVA, copper wound 11/0.433 KV, 50 Hz, Delta transformer with OLTCfor Voltage regulation andincluding standard fittings ,Name, Rating and Diagram Plate, Earthing terminals, Lifting lugs, Oil Level Indicator, Filter Valve With Plug, Drain cum sampling valve, Conservator with oil filling hole, Thermometer pocket, Dial type oil temperature indicator with max. Indicating pointer, Air release plug, Dehydrating Breather, Explosion vent, Inspection Cover, First Filling of Transformer Oil confirming to IS: 335, Marshaling Box with control wiring, Buchholz Relay, Oil Temperature Indicator, winding Temperature Indicator, Magnetic oil level gauge, Jacking pads& LV busbar. The transformer shall be tested and shall be meeting to IS:1180 Level I, Amendment-4 Std A. Technical Specifications for 1000kVA DTf. With OLTC as per IS:1180 Level I, Amendment-4 Std

-

-

-

... More
Supplying and laying 75mm*15mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/terminating with G.I nut, bolt, spring washer etc. as required .(jointing shall be done by overlapping and with 2 sets of G.I . nut bolt & spring washer spaced at 50mm).

200

-

-

... More
i. Capacity in KVA-1000kVA , ii. Type- Distribution Transformer iii. Transformer design & testing- IS 1180 Level – I Amendment – 4 Std, iv. Loading- IS 6600 v. Oil- IS 335, vi. Porcelain bushing- IS 3347, vii. Tolerance on electrical parameters- IS 2026 viii. Duty- Continuous duty, ix. Windings- E.G. Copper, x. Core- M3, xi. Type- Outdoor xii. Rated Input-11 Kv, xiii. Rated Output-.433 KV, xiv. Frequency-50 Hz, xv. No. of Phases- 3 xvi. Input configuration- Delta, xvii. Output Configuration- Star, xviii. Vector Group- Dyn 11 xix. No. of Steps-16, xx. Tapping(OLTC) - -5% to +15% in steps of 1.25% xxi. Cooling- Natural Convection Oil Cooling/Natural Convection Air cooling (ONAN) xxii. Max. Ambient temperature - 50º C, xxiii. Max. Oil temperature rise - 40º C xxiv. Max. Winding temperature rise - 45º C, xxv. HV side High voltage withstand test - 28 KV xxvi. LV side High voltage withstand test - 3 KV, xxvii. Mounting of cooling radiators- Fixed xxviii. Applied on LV side-0.866 KV, xxix. Induced on HV side-22 KV, xxx. HV side- Cable Box xxxi. LV side- Bus Duct, xxxii. Neutral- Provided, xxxiii. Losses at 50% Load at 75°C - 2.79W xxxiv. Losses at 100% Load at 75°C - 7.70kW

1

-

-

... More
C. The breakers shall have the following ratings: i.Type- Vacuum type ii.No. of poles-3 iii. Nominal System Voltage-11 KV iv. Highest System Voltage-12 KV v. Rated frequency-50+1.5Hz vi. Rated continuous current rating at Ambient temperature, as specified in IS: 13118 -1991-800 Amp Busbar current vii. Busbar Chamber-800 A copper bus bar, heat shrinkable PVC sleeved /powder coated with colour code. The current density 1.5 Amps/sq. mm. The busbar shall be high conductive electrolyte copper. viii. Impulse withstand test voltage-75 KV (peak) ix. One minute power frequency withstand test voltage-28 KV (rms x. Short time current rating Not less than-18.4 KA for 1 Second. xi. System neutral- Solidly earthed.

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.