Bridge Ropeway Tunnel And Other Infrastructure Development Corporation Of Uttarakhand Limited Tender
View complete overview of Uttarakhand BRIDCUL Tender
Bridge Ropeway Tunnel And Other Infrastructure Development Corporation Of Uttarakhand Limited - BRIDCUL Tender
Electrical and Electronics
Electrical Works
Eprocure
Opening Date30 Nov 2023
Closing Date21 Dec 2023
Tender Amount₹ 3,44,41,000
Costs
EMD
₹ 6,89,000Document Cost
₹ 5,900Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2023_BRID3_65997_1Bid Award Id
ViewTender No
1719/BRIDCUL/843/23 Dated 22/11/2023Tender Authority
Bridge Ropeway Tunnel And Other Infrastructure Development Corporation Of Uttarakhand Limited ViewPurchaser Address
-Website
http://uktenders.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
-
-
-
2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
3384.5
-
-
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
16268
-
-
2 X 6 sq. mm + 1 X 6 sq. mm earth wire
5215
-
-
4 X 10 sq. mm + 2 X 6 sq. mm earth wire
1382
-
-
4 X 6 sq. mm + 2 X 6 sq. mm earth wire
3050
-
-
Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. 2 Pair
3195
-
-
Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required.
945
-
-
Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface /recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
40
-
-
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
-
-
-
20 mm
9900
-
-
25 mm
2695
-
-
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
272
-
-
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
287
-
-
Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required.
82
-
-
Supplying and fixing of following ways surface/ recess mounting, Vartical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. 8Way (4+24), Double door
12
-
-
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 6way 4+18 Double Door
31
-
-
Supplying and fixing of following ways surface/ recess mounting, Vartical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. 4Way (4+12), Double door
6
-
-
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Single pole and neutral
-
-
-
Single pole
702
-
-
Single pole and neutral
38
-
-
Triple pole and neutral
11
-
-
Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
-
-
-
40A
28
-
-
63A
32
-
-
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/ coke and salt as required.
14
-
-
Supplying and laying 6 SWG G.I. wire at 0.50 meter below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.
840
-
-
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
431
-
-
P/F Hexagonal MS sheet fan box for ceiling fan clamp od internall dia 140mm, 73mm height top lid of 1.5mm thick MS sheet with its top surface hacked, MS clamp shall be made of 12mm dia MS bar bent to shape as per standard design.
475
-
-
Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
436
-
-
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
-
-
-
5/6 A switch
291
-
-
3 pin 5/6 A socket outlet
291
-
-
Telephone socket outlet
85
-
-
TV antenna socket outlet
45
-
-
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 3 module
95
-
-
Providing and fixing plain 16/0.20mm (0.50sqmm) twin circular flexible FRLS PVC insulated, PVC sheathed copper conductor cable direct on the wall with PVC clips etc. as required.
2370
-
-
Heigh Bay LED Light 100 W Ceiling mounting type
94
-
-
Supplying and fixing of wall Bracket.
71.7
-
-
36 W LED Batten tube 6500K
319.9
-
-
40 W LED Batten tube 6500K
49.3
-
-
300mm Bajaj propeller type ventlating fan with 300mm
64
-
-
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 3742019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
283
-
-
LED 12 W Recess mounting Down Lighter
154.2
-
-
20 W 6500K Batten LED Tube
567.1
-
-
36W 2x2 LED panel luminary
252
-
-
Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
1364
-
-
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.
106
-
-
Design, Fabrication, Supply, Erection,Testing and commisioning of Powder coated Main Distribution Panel fabricated out of 14 guage CRCA sheet steel in cubical, compartmentallised, FRLSee standing floor /wall mounted, dust and vermin proof, with reinforcement of suitable size angle iron, channel, T -iron or flats as required. Cable gland plates shall be provided on top as well as bottom of the panels. Panels shall be treated with all anti-corrosive process before painting as per specification. Panels shall be suitable for 415V, 3-Phase, Four wire, 50 Hz supply complete with earth bus and lifting hooks as required in case of large panels.Approval shall be taken for each panel before fabrication. (All hardwares like nuts and bolts used shall be Galvanized and Zinc passivated with CT PTs , Multifunction Meter,required Operating Handels and Mech. Interlocking fot Bus coupler MCCB
3
-
-
Building LT Panel as per specification with TP&N 300 amps BUS Bar
-
-
-
INCOMER 400 A, FP, MCCB ,50 KA
-
-
-
Outgoing - 200 amp 36 KA FP MCCB -4 no.,Outgoing - 125 amp 36KA FP MCCB-2 nos &Outgoing - 100 Amp 10KA FP MCB- 4nos.
-
-
-
Design, Fabrication, Supply, Erection,Testing and commisioning of Powder coated Distribution Bus Box fabricated out of 14 guage CRCA sheet steel in cubical, compartmentallised, FRLSee standing floor /wall mounted, dust and vermin proof, with reinforcement of suitable size angle iron, channel, T -iron or flats as required. Cable gland plates shall be provided on top as well as bottom of the panels. Panels shall be treated with all anti-corrosive process before painting as per specification. bus box shall be suitable for accomodating 8 nos Energy Meters as per UPCL Norms with a loose wire box and sealable bus bar Chamber. (All hardwares like nuts and bolts used shall be Galvanized and Zinc passivated
2
-
-
Incomer 400 A FP MCCB 36 KA BUS BAR 400 amps TP&N
-
-
-
Outgoings 250 A ,36 KA TP MCCB 1 No.
-
-
-
200 A ,36 KA TP MCCB 1 No.
-
-
-
125 A ,36 KA TP MCCB 2 No.
-
-
-
Providing & Fixing water Gyser (water Heater) 15 Liter
39
-
-
S/F single pole blanking plate in the existing MCB DB complete etc. as required.
220
-
-
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as
required.
-
-
-
40 A
20
-
-
63 A
23
-
-
Supplying and fixing 30 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 30 A "C" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
14
-
-
Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, "C" curve including connections, painting etc. as required. For AC
151
-
-
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate One Module for modular switches in recessincluding supplying and fixing Cat-6 Data Information Outlet, crimpling, connection, testing etc. as required.
235
-
-
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. 2 cable run
11750
-
-
Supplying installation testing commissioning of 24 Port, Gigabit Data switch Dlink with 2 U rack , cable maneger etc as reqd.
14
-
-
10W LED Batten Polycarbonate 6500K
105
-
-
Supplying and fixing 8 way, Double Door single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
40
-
-
Supply of 18W Inverter LED pr batten with backup 8 hrs
195
-
-
Providing and fixing of 100 amps 30 KA Four pole rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required
3
-
-
10 W LED Bulkhead With LED Bulb
56
-
-
Providing and fixing following breaking capacity Four pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required
-
-
-
125 A,36KA,FPMCCB
2
-
-
200 A,36KA,FPMCCB
13
-
-
Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required.
4
-
-
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run)
450
-
-
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run
90
-
-
Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of G.I.bolts, nuts, chuck nuts and spring washers etc. complete as required.
4
-
-
Providing and laying G.I. tape 32 mm X 6 mm from earth electrode directly in ground as required.
80
-
-
Supplying,installation,testing and commisioning of 500 Kva 11kV/0.433 kV outdoor Package type compact substation equipments comprising HT Panel, Dry type Transformers, HT cable, Bus trunking from Transformer to LT Panel, LT Panel, Automatic Power factor correction panel, Active Harmonic Filters,TVSS (Transient Voltage suppression system), SPD (Surge protection system), Essential panel,Earthing,required inter-connections, substation safety euipments including LT cabling from sub station to the buildings fed by the sub station.
1
-
-
A) HT SWITCHGEAR having 02 nos Fixed-Type Load Break switches and 01no. Fixed-Type VCB (feeding into Transformer), enclosed in common tank, made of robotically welded non-magnetic/non-ferritic Stainless Steel sheets, filled with SF6 gas acting as an excellent insulating medium, IP-67 tank design having leakage rate less than 0.1% per-annum, whereas it shall be Arc-Proof design with Internal Arc criteria of 20kA/1-sec individually. The Compact Switchgear shall be a front-flushed design with integrated spring-charging handle and associated Capacitive Voltage LED Indicators for arc-proof cable box, with associated Terminal Protector boots and front-facia semaphore mechanical indication for breaker ON/OFF/EARTH. The breaker will be provided with integrated Self-Powered 3OC+1EF relay with Low and High set for Over current and Earth Fault. Relay should have facility to display the maximum loaded phase current also.Relay shall record minimum 5 fault records with time stamping, and shall be operated via Resin cast RingCore Protection CTs of suitable ratio and burden
-
-
-
B) TRANSFORMER shall comprise of 500 KVA 11KV/433V DYn11 Copper Wound Cast Resin Dry Type Transformer with Off load tap links of +5% to -5% @2.5% with WTI scanner. Class of Insulation: H, Temperature rise 115 deg.C over ambient of 50 degrees. Losses (as per IS tol ) - and Impedance of 5%(Subject to IS Tol.) with WTI scanner and Surge arrestor on the HV side .
-
-
-
C) LV-PANEL shall be made up of 1.5/2mm thick CRCA sheet with 3 mm gland plates and consisting of:- - Incomer ACB from Transformer rated for 1200 A, 433V, 4P, 50kA with numerical microprocessor based OC+EF(LSIG) release, associated MFM, RYB, ON,OFF,TRIP LEDs. & Incomer for DG Set 1000 A, 433V, 4P, 50kA with numerical microprocessor based OC+EF(LSIG) release, associated MFM, RYB, ON,OFF,TRIP LEDs with feeding into 2000A, Aluminium busbar arrangement, Outgoings of 1 Nos 630A , 433V, 4P, 36kA with Thermal Magnetic based release for Overload and short circuit protections MCCB, 1 No. 400 A 433V, 4P, 36kA with Thermal Magnetic based release for Overload and short circuit protections MCCB, 1 NO. 250 A 433V, 4P, 36kA with Thermal Magnetic based release for Overload and short circuit protections MCCB, 1 NO. 125 A 433V, 4P, 36kA with Thermal Magnetic based release for Overload and short circuit protections MCCB 1 NO. 63 A 433V, 4P, 36kA with Thermal Magnetic based release for Overload and short circuit protections MCCB
-
-
-
D) OUTDOOR ENCLOSURE shall comprise of having construction of Galvanised Sheet Steel of thickness 1.5/2mm. The Enclosure shall have IP54 degree of protection for HT & LT switchgear compartment & IP23 degree of protection for Transformer compartment. The enclosure shall be Powder Coated. Each compartment will be provided with the door and pad locking arrangement. The Compartment illumination lamp with door operated switch shall be provided for HT,LT compartment with switch operated for transformer compartment. The Enclosure design shall be a type tested design as per latest IEC 62271-202 for Internal arc classification to the tune of 21kA for 1 sec for both IAC AB criteria.
-
-
-
S/F XLPE insulated screened PVC beded galvanized steel strip of wire armoured electric power cable (heavy duty) with aluminium conductor 11KV greds cross sectional area 240 sqmm as per diected by engineer-in-charge. For metering eqpt.
60
-
-
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
12
-
-
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe FRLSom earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
360
-
-
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/ coke and salt as required.
6
-
-
Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required.
300
-
-
Supplying and making end temination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed /XLPE aluminium couductor cable of 1.1 KV grade as required.
-
-
-
2x6
120
-
-
2x16
4
-
-
4x16
4
-
-
3.5x35
10
-
-
3.5x70
8
-
-
3.5x120
16
-
-
3.5x185
6
-
-
3.5 x 240 sq. mm
10
-
-
S/M OUTDOOR cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required: upto 300 sq. mm
2
-
-
supplying and making indoor cable end termination with heatshrinkable jointing kit complete with all accessories including
lugs suitable for following size of 3 core,300 sq.mm, XLPE aluminiumconductor cable of 11 KV grade as required :
3
-
-
S/E of three piece nonlinear resistor type lighting arrestor suitable for 3 wire, 11 KV overhead lines with rated voltage 9 KV (rms) with a nominal discharege current rating of 5 KV and complete with galvanised clamping arrangenment, G.I. bolts, nuts, washers etc. as required.
2
-
-
Supply 6 meter GI octegonal pole single arm with loop in box, Foundation Bolts etc.
30
-
-
Erection of Octagonal street light pole of 6 to 8 meter length in RCC 1:2:4 foundation including excavation, refilling, Reinforcement etc. as per Pole Manufacture design.
30
-
-
Supplying and fixing 60W LED streetlight made up of pressure die cast housing with toughned glass and individual LEDs with secondary optics and IP66 protection complete with all accessaries.
30
-
-
Supplying and Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade aluminium conductor armored of following size in the existing RCC/ HUME/ METAL pipe as required.
-
-
-
2x6 sq.mm
700
-
-
2x16 sq.mm
40
-
-
4X16 Sq.mm.
100
-
-
3.5x35 Sqmm
150
-
-
3.5x70 Sqmm
200
-
-
3.5x95 Sq.mm
100
-
-
3.5x120 sq.mm
250
-
-
3.5x 185 Sq.mm
250
-
-
3.5x240 Sqmm
350
-
-
3.5x300 sq.mm
80
-
-
Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required
-
-
-
80mm
50
-
-
110mm
30
-
-
150mm
70
-
-
Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required
-
-
-
300mm
8
-
-
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.
-
-
-
63mm
800
-
-
90mm
250
-
-
160mm
400
-
-
Supply installation testing and commissioning of 1.5 Ton 3 Star High wall Split AC (Hot and Cold) including initial charging etc. as reqqd.
4
-
-
Supply installation testing and commissioning of 2 Ton 3 Star High wall Split AC (Hot and Cold)including initial charging etc. as reqqd.
2
-
-
Supply installation testing and commissioning of 3 Ton 5 Star Ceiling Mounted AC (Cassette AC - Hot and Cold) including initial charging etc. as reqqd.
4
-
-