West Central Railway Tender

... More
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of etender.up.nic.in - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.

West Central Railway - WCR Tender

Works
Telecommunication Services
Ireps
Opening Date26 May 2025
Closing Date24 Jun 2025
Tender Amount₹ 3,62,81,152.7 
Notes
Download

AI Insights

Bid Capacity
... View More
The formula for bid capacity is detailed as Annexure-VI.
Technical Capacity
... View More
The required prior work experience for the bidder is mentioned in terms of financial eligibility criteria, which includes having a minimum average annual contractual turnover. Additionally, the tenderer must have successfully completed or substantially completed specific categories of work(s) during the last 7 years. These categories include: 1. Three similar works each costing not less than 30% of the advertised value of the tender, 2. Two similar works each costing not less than 40% of the advertised value of the tender, 3. One similar work costing not less than 60% of the advertised value of the tender. The average annual contractual turnover is calculated as an average of total contractual payments in the previous three financial years, as per the audited balance sheet.

Costs

Summary

1. Provision Of Alternate Communication For Control Circuits/block Working/other Circuits Like Uts/prs Through Wireless System For Various Ibs Location On Jabalpur Division Of West Central Railway. 2. Balance Work Of Enhancing Of Reliability By Provision Of High Availability Digital Axle Counter In Existing 05 Intermediate Block Signal In Et-mkp Section Jabalpur Division On West Central Railway

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Excavation of concrete foundation. All the material required are to be supplied by the contractor. This includes 1) Cement concrete foundation of size approx 3ftx3ftx3ft shall be prepared 03 for Lattice (guyies) mast. The exact size shall be decided on soil conditions.2) Cement concrete foundation of size approx 6ftx6ftx6ft shall be prepared for self supported mast. The exact size shall be decided on soil conditions.3) The ratio of casting of cement concrete foundation shall be 1:3:6 all the work will be executed as per specification and advised by site engineer.

112

5137

575406.72

... More
Transportation & Laying of GI/DWC/RCC pipes along with collars in trenches at places wherever required as per the instruction of the engineer at site.

162

71

11508.48

... More
Supply of INDICATIVE TYPE OF FUSE INSERTS. With holder 0.6 A (System, Rapid or Malnad Make). INSPECTION BY CONSIGNEE

70

73

5133.8

... More
Supply of Concrete Cable Marker as per drawing SDO/Cable Laying/020 INSPECTION BY CONSIGNEE

1380

263

363547.2

... More
Transportation and Laying of HDPE pipe as per approved cable route plan in the 13 excavated trench, taking due care while transporting and laying the same in the trenches or other protective works. Both the ends of the duct should be sealed with end plugs before laying and should remain sealed till blowing is done.

71.71

6432

461288.2

... More
Supply of self support mast/Complete Triangular 11" or higher Lattice (Guyies) Mast assembly along with mast mounting unit consists of: (a) Supply of Triangular 11" or higher Lattice 02 (Guyies) Mast/ Self Supported Mast Assembly with sections of approx 03 mtr. each (b) MS pipes with IS certification of outer diameter of 1" or higher should be used as per drawing attached as Annexure- II. Inspection by Representative of Engineer incharge. INSPECTION BY RITES Note: 1.Inspection to be done as per Annexure-II 2.Visual Inspection by RITES against test certificate &guarantee certificate of OEM(as applicable).

504

1980

998056.08

... More
Supply & installation of SPD for digital axle counters specification of 5V SPD for axle counter. SUPPLY PORTION INSPECTION BY CONSIGNEE

20

5068

101378.2

... More
Placing and securing of cable route marker in trenches at the specified interval and at diversion joint etc .along the cable route The work shall be done as per extant practice on WCR & the instruction of Rly engineer at site.

1380

15

20755.2

... More
Laying of signalling/Power/Telecom cable of various cores/sizes in trenches. as per 09 approved cable route plan in the excavated trench, inside GI, DWC Pipes etc. taking due care while transporting and sealing both the ends after laying. The cables are to be laid as per extent practice of WCR and as per the instructions of engineer at site. This includes transportation of cable from the consignee depot to site or as per instruction of engineer incharge.

35.7

6562

234269.47

... More
All work pertaining to Horizontal Directional Drilling (HDD)/Boring and trenchless cabling. It includes supply, transportation and insertion of self lubricated HDPE Pipe and laying of cables in boring under the track/ road / platform/ circulating area by using different sizes of pipes depending on total number of cables will he crossed. The depth of horizontal boring should he 02 minimum 2 mtr upto 3 mtr, from rail flange road level ground level as per site requirement and as per instructions of Railway Engineer in charge. This item will be used for track crossing of running lines. road crossing & circulating area. By using self-lubricated HDPE Pipe of 200mm outer dia and 175mm inner dia in the bore and laying of cables in the bore under the track/road/circulating area and any other critical area or as per instructions of site engineer. Thickness 3.5 to 4.1 mm as per specification no. IS 4984:1995 with latest amendment, Material Grade PE 63. INSPECTION OF SUPPLY PORTION BY CONSIGNEE.

250

3510

877695

... More
Supply of PVC Indoor Cable 1x 40x0.6mm dia. Colour coding of insulation of inner core shall be in four colour viz Yellow, white, pink & violet.IRS:S-76/89 INSPECTION BY RDSO

1

142663

142663.44

... More
Plastic Coupler INSPECTION BY CONSIGNEE

-

-

20

... More
Writing work of cable termination details of 6-quad, OFC, PIJF cables & equipment details at OFC Room/Cable hut & Station Building and wherever necessary as per direction of Engineer in-charge.

15

1220

18302.85

... More
Supply of INDICATIVE TYPE OF FUSE INSERTS. Without holder 0.6 A (System, Rapid or Malnad Make). INSPECTION BY CONSIGNEE

70

22

1551.2

... More
Excavation of trench as per cable route plan, 1.2 mtr deep, 300mm wide at the bottom along main line in normal soil, This work includes covering of cable laid in trenches by loose soil for a layer of 50 mm thickness approximately before covering by shahabad stone/bricks, clearing of route, 03 bushes etc and refilling of the trench by excavated soil and ramming after laying of the required quantity of cables as per instructions of Engineer at site. If it is not possible to reach the required depth at any location, then the contractor shall obtain prior approval of Engineer-in-charge before commencement of cable laying process and only then shall the proportionate payment be made to the contractor.

58.8

60208

3540259.8

... More
Installation of cable termination panel rack, mounting of isolation transformers, termination of underground jelly filled cables on the screw type terminals, supply of wiring material and wiring of circuitry as per instructions of engineer at site.

14

5114

71609.58

... More
Supply of 9U Rack. Inspection Authority: Consignee INSPECTION BY CONSIGNEE

-

-

3

... More
Supply of INDICATIVE TYPE OF FUSE INSERTS. With holder 1.6 A (System, Rapid or Malnad Make). INSPECTION BY CONSIGNEE

-

-

9

... More
Making of straight through joint for under ground cable jelly filled cable/6 Quad cable with joint ing kits supplied against supply item and construction of bricks chamber for protection of joints with all contractor materials.

-

-

19

... More
Hand held service terminal/ portable service terminal compatible with Management System for RF links. INSPECTION BY CONSIGNEE

1

225273

225273

... More
Excavation of trench as per cable route plan, 1 mtr deep, 300mm wide at the bottom along main line in hard soil / murrum, This work includes covering of cable laid in trenches by loose soil for a layer of 50 mm thickness approximately before covering by bricks.

4.71

86010

405107.1

... More
Excavation of cable trench 1m deep and 300mm wide across the track, for track crossing and refilling after laying of DWC/RCC/GI pipes. The work shall be done as per extant practice on W.C. Rly & instruction of Rly engineer at site.

-

-

5

... More
Supply & laying of well burnt bricks of size 225x100x75mm inside the trench (with the brick length being perpendicular to cable route) after laying of cable in station area from Outermost to Outermost signal or at any other location as per instruction of Engineer at site.

598686

3

2275006.8

... More
Installation of maintenance free Single Earth Pit which includes the following:- a) Excavation/ Auguring/ Boring of single earth pit of 100 mm to 125 mm dia to the depth of approx. 2.8 meter. b) Insertion of 3.0 meter electrode and penetrating it at least 0.2 meter by pushing gently with sledge hammer where the natural soil is assumed. c) Filling of earth pit with Earth Enhancement Compound (EEC) in slurry form and backfilling. d) Carrying out exothermic weld connection on single earth electrode to a copper tape of 150x25x6mm. e) Carrying out exothermic weld connection on the copper tape of 150x25x6mm on Earth Electrode for connecting two 35 sq mm cables for redundancy. f) The exothermic welding material for bonding the earth system shall be procured from RDSO approved firms, which includes graphite moulds, clamps, weld metal powders. g) Digging a trench to a depth of at least 0.5 m and run the 02 (two) 35 sq mm earth conductor (procured against supply 05 item) from Earth pit to MEEB. h) Routing and termination of 02 (two) 35 sq mm 300x25x6 mm MEEB, which is to be fixed inside the equipment room with 02 (two) insulation studs, with stainless steel Nuts & Bolts. i) 300 X 300 X 300 mm (inside dimension) concrete Earth pit with a concrete lid, approx 50 mm thick with pulling hooks, shall be provided to cover the pit. Back side of the cover will be painted in black and date of the testing and average resistance value shall be written in white paint. Note: At certain locations it may not be possible to achieve earth resistance of less than 1.0ohm with one earth electrode/pit due to soil resistivity. In such case provision of loop earth consisting of more than one earth pit shall be done. For inter connection of two earth pits copper tape of size 25X2sq. mm shall be provided by contractor. The number of pits required shall be decided based upon the resistance achieved for the earth pital ready installed. The procedure mentioned above for one earth pit shall be repeated for other earth pits. The other earth so installed for the purpose of loop earthing arrangement shall be counted as separate earth. "OEM certification as per RDSO TAN 3006 Ver 3.0 or latest to be given after commissioning"

52

9116

474056.96

... More
Blowing and drawing of OFC through already buried HDPE duct, taking due care while 14 transporting and sealing both the ends after blowing. The cable should be blown according to the technical instructions of the manufacturer and the instructions of the site in-charge manufacturer and the instructions of the site in-charge.

71.93

15641

1125121.15

... More
Supply of Phenolic Laminated sheet, resin bonded 10mm thick, grade P3 in standard size of 1.22 x 1.22 Mtr as per spec. No IS 2036 of 1974 . Inspection by Consignee

30

3409

102271.8

... More
Cement concrete work in the ratio of 1:3:6 with contractors own as per instructions of site engineer.

6

3992

23957.22

... More
Fixing of GI pipes for crossing the culverts, stone bridges etc. and concreting the ends with brick masonry at both ends as per the instructions of Rly. Engineer at site with Contractor's 16 materials. The brick masonry at the ends shall be done with well-burnt bricks & cement mixture of 1:3 ratios. (Supply of GI pipes is not covered in this item).This includes drilling of 3 nos. of 6 mm holes per meter on the periphery of GI pipe as per instruction of engineer at site. This also includes fixing of GI pipe with contractors own MS Chanel, clamps of proper size etc as per instructions of engineer at site.

360

88

31734

... More
Splicing of 24 fibre OFC from both sides for straight through joint and testing. This includes excavation of pit & backfilling & supply of all type of material and any other equipment of all types.

31

5437

168568.39

... More
Cable Sealing Plug INSPECTION BY CONSIGNEE

-

-

19

... More
Site survey, transportation, installation, testing and commissioning of 200 Mbps or 01 higher OFDM outdoor TDM Redundant Backup (4xE1) Radio Equipment with Ethernet plus fully functional 4XE1 Auto Changeover System in unlicensed frequency band of 5.8 Ghz for back-up RF link ( Automatic changeover to wireless in case of wire line failure and vice-versa) and all accessories.

20

32986

659723.4

... More
Cabinet with wiring arrangement of DC-DC converter for 08 Nos. suitable for statcon make IPS (Material to be inspected by RDSO). INSPECTION BY RDSO

15

46151

692277.9

... More
Supply of Time Element Relay (Clock work type) AG timer of Siemens Make (Nos RSSK 30/0052) or functional equivalent with timer range up to 120 seconds. INSPECTION BY CONSIGNEE

35

11431

400089.2

... More
Supply of 200 Mbps or higher OFDM outdoor TDM Redundant Backup (4xE1) Radio Equipment with Ethernet plus fully functional 4XE1 Auto Changeover System in unlicensed frequency band of 5.8 Ghz for back-up RF link (Automatic Change-over to wireless in case of wireline failure and vice versa) alongwith DC power supply arrangement and accessories as per enclosed specifications. The unit consist of 01 no. outdoor unit (ODU) + 01 no. indoor unit (IDU) as per RDSO spec no. RDSO/SPN/TC/91/2012 Rev-1 or latest amendment wireless back-up system consisting of : (a) IDU E1 indoor unit for E1 back-up, 2 Ethernet interface, supporting wide range DC input (20 to 60 VDC). 01 (Make: RADWIN or similar) (b) ODU/F58 Outdoor unit for external antenna for 5.8 GHz band INDIA unlicencsed. (Make : RADWIN) (c) 5.8 GHz external antenna with gain of 28 dbi or higher along with mounting arrangement. Inspection Authority: RITES (Visual Inspection) (d) STP cable as per requirement. (e) STP RJ-45 connectors. (f) Site survey. (g) application software on CD-ROM contains installation & operational manual and link budget calculator. Work will be carried either by OEM or his authorized representative. Note-1 Contractor will supply all the document in 2 hard copy and 1 CD along with each equipment. In case the distance of tower is more than 45 meter from the indoor units, necessary modem/repeater/amplifier should be provided by vendor. Note : 1.Inspection to be done as per Annexure-I. 2.Visual Inspection by RITES against test certificate & guarantee certificate of OEM(as applicable). Inspection Authority: RITES (Visual Inspection)

20

537596

10751923.2

... More
Supply of PVC Indoor Cable 1x60x0.6mm dia. Colour coding of insulation of inner core shall be in six colour viz Blue, Red, Green, Grey, Brown & Black .IRS:S-76/89. INSPECTION BY RDSO

1

195984

195984.85

... More
Supply of Tag Blocks 200 way with cover as per IRS: S- 77/2006 (Rev. 1) with latest amendment.

40

1391

55678.4

... More
Supply & installation of SPD for 24 V SPD for power supply cum data, line for axle counter. SUPPLY PORTION INSPECTION BY CONSIGNEE

20

3335

66710.6

... More
Supply of cartridge fuse blockmade of PBT as per RDSO Drg.Nos. SA - 23748 Alt. 4 and Spec.Nos. IRS-S-75/2006 with Inspection by RDSO

150

153

23016

... More
Transportation, installation, testing and commissioning of self support mast/Complete Triangular 11" or higher Lattice (Guyies) Mast. The sections should be painted orange/red and white alternatively.

504

4669

2353609.44

... More
Supply of Heat shrinkable straight through joint for UG cables with all accessories as per RDSO spec. no."IRS /TC/77/2012 (rev-3) with amend.-1 &2 or latest for 6 quad cable 0.9mm dia (TSF-2)joint suitable for 6 quad cable. INSPECTION BY CONSIGNEE.

26

2024

52632.06

... More
Supply of lamp holders and switches, two pin (Bakelite type) for location boxes (Anchor make or ISI mark) INSPECTION BY CONSIGNEE

30

79

2391.9

... More
Supply of OFC integrated access device 1U height or1.5 U height/19" rack mountable for LVCD/Digital Axle Counter purpose with four tributary slots & four potentional free contacts to konw quad status , front panel Quad indication status vide LEDs, Optical support vide 4 SFP port supporting TDMoIP in the unit supporting dual core OFC and 04 100/1000 mbps Ethernet port (POE or NON POE as required at site ) for surveillance/smoke detector, optical SFP ports provided distance support to be 20 KMs, unit to support one E&M card supporting four 2W/4W configurable & four quad 05 port 2W/4W. Each port configurable to support axle counter/UFSBI/control phone/EC/RTU and one telnet/SNMP port, unit to support 04 E1 ports in addition to 04 SFP ports of TDMoIP, dual DC power supply 18 to 72 VDC support , unit to support change over mechanism automatic between E&M (V.21) to E1 port & optical fiber TDMoIP (SFP) & quad path for E&M interface option, one number cable to be provided along with E&M. Equipment should be able to integrate with STM E1 & IPMPLS 1Gbps ports FABIO 2CX+/OFC/ DC & module 2W/4W four port E&M (1+1) protection Make: TEAM ENGG/FABIO or equivalent. Note: Visual Inspection by RITES against test certificate & guarantee certificate of OEM (as applicable). INSPECTION BY RITES.

20

185119

3702398.2

... More
Supply of basic material to construct Unit Maintenance Free Earth consisting as per RDSO Spec No. RDSO/ SPN/ 197/2008 (or with latest Amend) consisting of : a) Copper bonded steel electrodes of 3.0 m long, 17.2 mm dia with copper bonding thickness of min 250 micron and UL listed 06 and marked - 1 No. b) Earth Enhancement compound of approved brand supplied in sealed bags of min 10 Kgs - 3 Nos. c) Copper Strip of 150 x 25 x 6mm to terminate Earth Rod - 2 No. d) Copper Strip of 300 x 25 x 6mm (MEEB) - 1 No. Procurement should be done by RDSO approved source. "OEM certification as per RDSO TAN 3006Ver 3.0 or latest to be given after commissioning" INSPECTION BY RITES

52

18729

973953.76

... More
Cutting of all types of Roads prepratory to trenching & excavation to depth of 1 Mtr X 300 mm wide approximately and refilling, after laying of RCC/GI/DWC pipe and to restore the road to original condition. The work shall be done as per extant practice

394

227

89796.54

... More
Supply and Installation & fixing of earth electrode assembly including earth wire 23 connected through GI wire 8 SWG supported on M.S. flat of size 6mm x 40mm to earth electrode for signaling Equipment. Contractor will bring Earth enclosure and all other material required for provision of earthing. SUPPLY PORTION INSPECTION BY CONSIGNEE

30

3578

107362.5

... More
"Supply of Lightning Protection System consist of:" 1.) Class D 48V SPD - 1 Nos. 2.) Copper Lightning Arrestor - 1 Nos. 3.) LPU - 1 Nos. 4.) Aviation Lamp - 1 Nos. 5.) RF Surge Arrestor - 1 Nos. INSPECTION BY RITES

20

74233

1484673.8

... More
Preparation of Cable way 150 mm wide at the bottom and 300 mm deep in rocky area & refilling the same (after cable-laying) with concrete mixture of proportion 1:3:6 and grouting the ends at either side of the rocky portion using concrete mixture with Contractors own material.

1356

593

804365.64

... More
Installation of Lightning Protection System consist of: 1.) Class D 48V SPD - 1 Nos. 2.) Copper Lightning Arrestor - 1 Nos. 3.) LPU - 1 Nos. 4.) Aviation Lamp - 1 Nos. 5.) RF Surge Arrestor - 1 Nos

20

5710

114205.6

... More
Cutting of all types of platforms, trenching & excavation to depth of 300 mm x 300mm 17 wide approx. and refilling after laying of RCC/DWC/GI pipes and repairing the platform to restore to original condition. This also includes transportation and laying of RCC/DWC/GI pipes and to its restore the platform to its original condition. The work shall be done as per extant practice on W.C.Rly and as per instructions of Rly. Engineer at site.

450

227

102559.5

... More
End Plug INSPECTION BY CONSIGNEE

-

-

18

... More
Supply of ARA Terminal Block made of PBT as per Drg No SA 23741 alt 3 & spec. No IRS S 75/91 with latest amendments with disconnecting links as per Drg no. RST/11336. INSPECTION BY RDSO.

800

129

103880

... More
Splicing , Termination , Testing & Commissioning of 24 fibre cable in fibber management system with all installation material, connectors , fittings etc. As per instructions of site engineer. FMS with splicing materials supplied.

35

10625

371875

... More
Supply of Non-deteriorating type low voltage cartridge fuse rate current 2 Amp / 4 Amp in equal proportion round head type as per specification Nos. IRS/S/78/92 with latest amendment. Inspection by RDSO

280

57

16142

... More
Supply of PVC insulated flexible wire 16/ 0.2 mm dia as per RDSO spec. Nos. IRS:S- 76/89 with latest amendments of various colours. INSPECTION BY CONSIGNEE.

4

5056

20224

... More
Supply, Transportation & installation of prefab RCC OFC chamber (specification as per drawing attached No RAILTEL/2002 /PFB/0487 enclosed) & filling with river sand & termite chemical after jointing work is done. SUPPLY PORTION INSPECTION BY CONSIGNEE

35

8318

291139.45



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.