The UPPTCL has issued a formal invitation for competitive bids for the Uttar Pradesh Power Transmission Corporation Limited project, for Supply And Installation Of Fire And Smoke Detector System At 400kv Substation, Sultanpur Under Electy. 400kv Substation Division, Sultanpur in Sultanpur, Uttar Pradesh. The bid opening date for this tender is 08-04-2025 and the last date for bid submission is 30-04-2025. Interested bidders for Uttar Pradesh Power Transmission Corporation Limited tender can download the important documents here to check the tender amount, scope of work, eligibility criteria and technical requirements.
Uttar Pradesh Power Transmission Corporation Limited - UPPTCL Tender
Opening Date8 Apr 2025
Closing DateCancelled
Tender AmountRefer Documents
Costs
EMD
₹ 5,000Document Cost
₹ 590Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_UPTCL_1013024_2Tender No
T. No. 37/ETCS/2024-25Tender Authority
Uttar Pradesh Power Transmission Corporation Limited ViewPurchaser Address
-Website
http://https://upenergy.in/upptcl
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Supply, Installation, Testing & Commissioning of Response Indicator LED Assembly of standard make like System Sensor /Agni Suraksha /Agni Devices/Daksh/Alpha/ Apollo/Edward, including making of required Electrical connections. The Response Indicator Lamp Assembly should consist of LED Lamp, Lamp Holder. The Assembly Housing should be suitable for Surface/Flush mounting & Should be made of 1.5 mm thick sheet Steel & the facia with 3 mm thick Acrylic Sheet mounted outside the cabin. In normal circumstances, the Lamp should flicker but inthe event of Fire, the Detector inside the Cabin should sense the fire and the Lamp should glow.
40
-
-
... More
Supply, Installation, Testing & Commissioning of Fire Alarm & Detection System in the Main Control Room, Relay Room, Carrier Room, Battery Room, Cable gallery, Emulsifier/Fire Hydrant room, ACDB Room J.E. Room, Committee Room, AC Room etc. at 400KV Substation Sultanpur, with all cost of men, materials, mise. Consumables, T&P etc. required for the job as per details below:
-
-
-
... More
Supply, Installation, testing & Commissioning of Manual Call Point, Break Glass typs housed in M.S. Sheet Enclosure Box of standard make like System Sensor/ Agni Suraksha/Agni Devices/Alpha/ Apollo/Edward /Honeywell/ Zicom, including making of required Electrical connections. The Glass Cover should be fixed in such a way that the actuating Push Button is kept depressed as long as the Glass is intact & released when the Glass is broken. A small Steel Hammer should be attached to the Assembly with a Steel Chain to facilitate breaking the Glass. The Manual Call Point should be suitable for the surface mounting (fully / partly released), with 5 mm high Red Colour painted/ Sticker word' In case of Fire, Break Glass' should be provided on the front face.
4
-
-
... More
Supply, Installation, Testing & Commissioning of 8-12 Zone Conventional fire detection and fire alarm control panel Microprocessor Based Conventional Fire Alarm Control Panel with Auto Display as per IS: 2189:1999, suitable & matching with Manual Call Point, Electronic Hooter etc. of the standard make like System sensor /Agni Suraksha/Agni Devices/ Daksha/ Alpha/Apollo/ Edward/ Honeywell/ Zicom, including making of required Electrical connections.
1
-
-
... More
Supply & Laying of 25mm dia. M.S. Conduit Pipe, as per Requirement of site.
500
-
-
... More
Supply & Laying of 2Cx1.5 Sq .mm size 1100 Volt Grade PVC Insulated & Sheathed FRLS Copper Cable of Standard Make and should comply with IS:2189 & IS:732 amended up to date along with Fixing of crimping type & suitable size Copper Lugs as per requirement for making of Electrical Connections.
600
-
-
... More
supply, Installation, Testing & Commissioning of electronic hooter 11db / 24 Volt D.C. with strobe (ABS-V) of standard make like System Sensor /Agni Suraksha /Agni Devices/Daksh /Alpha /Apollo/Edward/Honeywell/Zicom, including making of required Electrical connections. The Enclosure should be 1.5 mm thick, duly painted & marked 'FIRE ALARM'. AII Hooters should produce a similar sound & should maintain the steady sound during operation. The Thermal Detector should meet the requirement as per EN54 and Tested by Approved Laboratory.