The PVVNL has issued a formal invitation for competitive bids for the Pashchimanchal Vidyut Vitran Nigam Limited project, for Construction Of 11/0.4 Kv Substation, Capacity Enhancement, Line Construction, Replacement Of Worn Out Wires, Cable Poles, Replacement Of Wires, Guarding, Ht And Lt Line Construction, System Improvement Work. in Hathras, Uttar Pradesh, with an estimated contract value of Rs. 3,40,00,000. The bid opening date for this tender is 31-05-2025 and the last date for bid submission is 16-06-2025. Interested bidders for Pashchimanchal Vidyut Vitran Nigam Limited tender can download the important documents here to check the scope of work, eligibility criteria and technical requirements.

Pashchimanchal Vidyut Vitran Nigam Limited - PVVNL Tender

Works
Civil And Construction
Energy, Oil and Gas
Building Construction
Electrical and Electronics
Electrical Works
Eprocure
Opening Date31 May 2025
Closing Soon16 Jun 2025
Tender Amount₹ 3,40,00,000 
Notes
Download

AI Insights

Class Of Bidder
Technical Capacity
... View More
The bidder should have successfully completed turnkey/semi-turnkey work of a similar nature in the last five financial years. The requirements for prior work experience are as follows: 1. A single turnkey/semi-turnkey order with a minimum order value of 60% of the estimated cost of the present tender specification. 2. A maximum of two turnkey/semi-turnkey orders with a minimum order value of 40% each of the estimated cost of the present tender specification. 3. A maximum of three turnkey/semi-turnkey orders with a minimum order value of 30% each of the estimated cost of the present tender specification. The bidder should also have successfully erected and commissioned similar or higher rating work.

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
PCC Poles 11 mtr. long

642

-

-

... More
PCC Poles 8.5 mtr. long

400

-

-

... More
Safe carriage of store material from store center to je store/nearest work site & then to pit site with loading & unloading at both ends respectively without contractor porvading all item distance within- 0 to 50 Km

-

-

-

... More
T/F 63 KVA 11/0.4 KV

2

-

-

... More
T/F 100 KVA 11/0.4 KV

16

-

-

... More
T/F 250 KVA 11/0.4 KV

47

-

-

... More
T/F 400 KVA 11/0.4 KV

2

-

-

... More
ACSR Dog Conductor

17730

-

-

... More
ACSR Weasel Conductor

1670

-

-

... More
LT ABC 3*50 sq mm

450

-

-

... More
LT ABC 3*95 sq mm

2650

-

-

... More
LT ABC 3*120 sq mm

32597

-

-

... More
11 KV XLPE CABLE (3X70) sq.mm

1230

-

-

... More
11 KV XLPE CABLE (3X120) sq.mm

190

-

-

... More
11 KV XLPE CABLE (3X185) sq.mm

3410

-

-

... More
11 KV XLPE CABLE (3X300) sq.mm

250

-

-

... More
33 KV XLPE CABLE (3X300) sq.mm

380

-

-

... More
33 KV V TYPE CROSS ARM

40

-

-

... More
11 KV V TYPE CROSS ARM

510

-

-

... More
11 KV VCB N/G CTR 200/100/5

3

-

-

... More
11 KV VCB N/G CTR 600/300 5A

3

-

-

... More
1*240 SQ MM SINGLE LEAD

8560

-

-

... More
1*400 SQ MM SINGLE LEAD

7750

-

-

... More
1*120 SQ MM SINGLE LEAD

5350

-

-

... More
11 KV do FUSE SET

335

-

-

... More
11 KV Pin Insulater

1845

-

-

... More
11 KV Disc Insulater

400

-

-

... More
33 kv pin insulater

105

-

-

... More
33 KV Disc Insulater

22

-

-

... More
11 KV CT 600/300/5

8

-

-

... More
11 KV CT 400/200/1

4

-

-

... More
11 KV PT

3

-

-

... More
33 KV CT 400/200/1

6

-

-

... More
24 VOLT BATTER set

8

-

-

... More
24 VOLT BATTER CHARGER

8

-

-

... More
33 KV CONTROL PANEL SINGLE T/F

2

-

-

... More
33 KV TPMO

2

-

-

... More
Loading, Safe carriage & unloading of heavy stock material channel, Angle and other site requerment any mattrial ETC from store center to JE Store/Sub Station with proper stacking of material, distance within 30 Kms.

10

-

-

... More
Erection of Single pole all size as per RESPO Drawing, fitting with all accessories Pin Insulator, F Bracket and etc as per direction of Engineer Incharge including the cost of labour, T&P and carrier etc. required for proper completion of work.

-

-

-

... More
PCC Poles 11/13 mtr. long

472

-

-

... More
PCC Poles 8.5 mtr. long

298

-

-

... More
Excavation of For Each and grouting of Single Pole as per RESPO Drawing and as per direction of Engineer Incharge including the cost of labour, T&P and carrier etc. The support shall be grouted with cement, sand and stone ballast in ratio 1:4:8 including the cost of Cement, Sand, Stone Ballast, Stone Pad etc. as per actual site requirement

-

-

-

... More
PCC Poles 9/11/13 mtr. long

472

-

-

... More
PCC Poles 8.5 mtr. long

298

-

-

... More
Erection of Dobule Pole all size as per RESPO Drawing, fitting with all accessories Pin Insulator, F Bracket and etc as per direction of Engineer Incharge including the cost of labour, T&P and carrier etc. required for proper completion of work.

-

-

-

... More
PCC Poles 9/11/13 mtr. long

85

-

-

... More
PCC Poles 8.5 mtr. long

51

-

-

... More
Excavation of For Each and grouting of Dobule Pole as per RESPO Drawing and as per direction of Engineer Incharge including the cost of labour, T&P and carrier etc. The support shall be grouted with cement, sand and stone ballast in ratio 1:4:8 including the cost of Cement, Sand, Bricks/Stone Ballast, etc. as per actual site requirement

-

-

-

... More
PCC Poles 9/11/13 mtr. long

85

-

-

... More
PCC Poles 8.5 mtr. long

51

-

-

... More
Laying sagging stringing and binding and jumpering etc of following Conductor/ABC/XLPE of size on the newly erected poles as per RESPO manual and as per direction of Supervising Engineer. It includes the cost of labour, T&P, carrier etc. required for proper completion of work.

2500

-

-

... More
33 KV XLPE CABLE (3X300) sq.mm

380

-

-

... More
11 KV XLPE CABLE (3X300) sq.mm

250

-

-

... More
11 KV XLPE CABLE (3X185) sq.mm

4110

-

-

... More
11 KV XLPE CABLE (3X70) sq.mm

1230

-

-

... More
ACSR Dog Conductor

17730

-

-

... More
ACSR Weasel Conductor

1670

-

-

... More
LT ABC 3*120 sq mm

32597

-

-

... More
LT ABC 3*95 sq mm

2650

-

-

... More
LT ABC 3*50 sq mm

450

-

-

... More
Mounting of Distribution Transformers.

-

-

-

... More
T/F 63 KVA 11/0.4 KV

2

-

-

... More
T/F 100 KVA 11/0.4 KV

16

-

-

... More
T/F 250 KVA 11/0.4 KV

47

-

-

... More
Installation and fixing of Distribution Transformers.

-

-

-

... More
T/F 63 KVA 11/0.4 KV

2

-

-

... More
T/F 100 KVA 11/0.4 KV

16

-

-

... More
T/F 250 KVA 11/0.4 KV

47

-

-

... More
Providing and fixing of Telless Unit with Structure.

-

-

-

... More
Providing, fabricating carrying & fixing of Henley type Tailless Fuse Unit hook type arrangement single circuit having 3 Phase + Neutral arrangement ( 1 Nos single circuit tailless unit of heavy duty brass material stud type taillness unit having 300AMP capacity in box) in frame made of 70cmX50cmX6mm frame MS angle box with heavy duty Aluminium lugs suitable for 300 Amp load on at least 2 ft height from ground on plinth for safe installation or fixing of tailness unit box at MS angle frame support on Pole horizontially/vertically as per site requirement on available pole support at safe height as per site conditions for electrical safety with making the connection at 100 kva T/f and Line side complete. All material except T/F LT PVC cable be provided by the contractor.

56

-

-

... More
Providing, fabricating carrying & fixing of Henley type Tailless double circuit Fuse Unit hook type arrangement having 3 Phase + Neutral arrangement in each leg ( 2 Nos single circuit tailless unit of heavy duty brass material stud type taillness unit having 500AMP capacity in box) in frame made of 70cmX50cmX6mm frame MS angle box with connecting suitable length copper busbar 50mm wide and 6mm thick for connecting studs for main T/F cable with heavy duty Aluminium lugs suitable for 500 Amp load on at lest 2 ft height from ground on plinth for safe installation or fixing of tailness unit box at MS angle support frame on Pole horizontially/vertically as per site requirement on available pole support at safe height as per site conditions for electrical safety with making the connection at 250 kva T/f and Line side complete. All material except suitable T/F LT PVC cable be provided by the contractor.

187

-

-

... More
Providing, fabricating carrying & fixing of Henley type Tailless double circuit Fuse Unit having 3 Phase + Neutral arrangement in each leg ( 2 Nos single circuit tailless unit of heavy duty brass material stud type taillness unit having 600AMP capacity in box) in frame made of 70cmX50cmX6mm frame MS angle box with connecting suitable length copper busbar 50mm wide and 6mm thick for connecting studs for main T/F cable with heavy duty Aluminium lugs suitable for 600 Amp load on at lest 2 ft height from ground on plinth for safe installation or fixing of tailness unit box at MS angle support frame on Pole horizontially/vertically as per site requirement on available pole support at safe height as per site conditions for electrical safety with making the connection at 400 kva T/f and Line side complete. All material except suitable T/F LT PVC cable be provided by the contractor.

58

-

-

... More
Providing, fabricating carrying & fixing of Henley type Tailless triple circuit Fuse Unit hook type arrangement having 3 Phase + Neutral arrangement in each leg ( 3 Nos single circuit tailless unit of heavy duty brass material stud type taillness unit having 800AMP capacity in box) in frame made of 70cmX50cmX6mm frame MS angle box with connecting suitable length copper busbar 50mm wide and 6mm thick for connecting studs for main T/F cable with heavy duty Aluminium lugs suitable for 800 Amp load on at lest 2 ft height from ground on plinth for safe installation or fixing of tailness unit box at MS angle support frame on Pole horizontially/vertically as per site requirement on available pole support at safe height as per site conditions for electrical safety with making the connection at 630/1000 kva T/f and Line side complete. All material except suitable T/F LT PVC cable be provided by the contractor.

2

-

-

... More
Erection of stay set including the work of nozelling etc. as per RESPO manual and also including the cost of all grouting material, labour, T&P etc required for proper completion of work.

193

-

-

... More
Grouting of stay set including the work of nozelling etc. as per RESPO manual and also including the cost of all The support shall be grouted with cement, sand and stone ballast in ratio 1:4:8 including the cost of Cement, Sand, Stone Ballast, Stone etc. as per actual site requirement , labour, T&P etc required for proper completion of work.

193

-

-

... More
Providing and fixing of Barbed wire.

1270

-

-

... More
Fixing of earthing rod and Wire as per RESPO manual and as per direction of supervising engineer including the cost of labour, T&P etc. required for proper completion of work.

365

-

-

... More
Cutting/drilling/Welding of MS Channel Top Channal, site channel, site angle, Dropper Channal & Cross brassing angle and MS mattriel Including the work of fixing on STP Pole for construction of the line.

11325

-

-

... More
Making Jumpers on Section Points, by fixing of proper sizes, suitable for ACSR Conductor. Sectional Double/Four Pole.

251

-

-

... More
Mounting of 11 KV VCB N/G CTR 200/100/5 Sub Station to Control Room by Hydra and manual Labour.

3

-

-

... More
Mounting of 11 KV VCB N/G CTR 600/300 5A Sub Station to Control Room by Hydra and manual Labour.

3

-

-

... More
Fixing/Installaiton of 11 KV VCB N/G CTR 200/100/5

3

-

-

... More
Fixing/Installaiton of 11 KV VCB N/G CTR 600/300 5A

3

-

-

... More
Making of new Plinth With material sand brick etc.of size 6x6x6 sq ft for distribution Transformers.

47

-

-

... More
Repairing of old damaged Plinth With material of size 6x6x6 sq ft for distribution Transformers.

-

-

-

... More
removal of tranformer from damaged plinth to trolly

75

-

-

... More
repairing of old plinth with material sand brick etc. as per site requirement

75

-

-

... More
reinstalling of transformer kept on trolly to plinth

75

-

-

... More
Fixing of 33 KV V TYPE CROSS ARM

40

-

-

... More
Fixing of 33 KV Disc Insulater

22

-

-

... More
Fixing of 33 KV Pin Insulater

105

-

-

... More
Fixing of 11 KV V TYPE CROSS ARM

529

-

-

... More
Fixing of 11 KV Pin Insulater

1823

-

-

... More
Fixing of 11 KV Disc Insulater

80

-

-

... More
Providing of Three Phase Distribution Box Direction of Engineer incharge

577

-

-

... More
Fixing of Three Phase Distribution Box

577

-

-

... More
Fixing of Battery set with charger

8

-

-

... More
Providing of G.I Pipe 6 inch dia

10

-

-

... More
Fixing of G.I Pipe 6 inch dia

10

-

-

... More
Providing of 11 KV fuse Set Direction of Engineer incharge

335

-

-

... More
Fixing of 11 KV FUSE SET

335

-

-

... More
Chopping of branches of trees of eucalyptus, Neem, Keekar and other kind of trees along the route of the line and disposal of the same at suitable place.

6

-

-

... More
Providing and Fixing of Chemical Earthing

282

-

-

... More
Providing and Fixing of GI Strip for earthing regarding

1410

-

-

... More
Providing and installing OF MS STRIP/angle (65x65x6) sq mm for fencing long as per site required direction of Engineer incharge

117

-

-

... More
Providing and installing OF MS STRIP/angle (65x65x6) sq mm for fencing as per site required direction of Engineer incharge

20

-

-

... More
Providing and fixing of Water Level Earthing

12

-

-

... More
Providing and fixing copper coin, copper wire with strip/hook purpose for water level earthing

12

-

-

... More
Providing and fixing of HDPE Pipe for cable

760

-

-

... More
Providing and fixing of Lug BRASS 250 kva

840

-

-

... More
Providing and fixing of Lug BRASS 400 kva

420

-

-

... More
Providing and fixing of Lug BRASS 630 kva

40

-

-

... More
Providing and fixing of Lug BRASS 1000 kva

38

-

-

... More
Providing and fixing of Bus bar brass

1090

-

-

... More
Providing and fixing of Bus bar Aluminium

10

-

-

... More
Fixing of 11 KV CT 600/300/5

9

-

-

... More
Fixing of 11 KV CT 400/200/1

5

-

-

... More
Fixing of 11 KV PT

2

-

-

... More
Fixing of 33 KV CT 400/200/1

6

-

-

... More
Fixing of 33 KV CONTROL PANEL SINGLE T/F

2

-

-

... More
FIXING OG 33 KV TPMO

2

-

-

... More
Construction of safty wall between two power transformer at different substation with materai such as sand,brick etc. of as per site required direction of Engineer incharge

6

-

-

... More
Construction of safty wall between two distribution transformer kept at same plinth at different locations with materai such as sand,brick etc. as per respo norms as per site required direction of Engineer incharge

7

-

-

... More
Drilling of dia 160 mm in Two Parallel bores by trench less Method by horizantal Boring by HDD Machine .

760

-

-

... More
Laying of HDPE Pipe through HDD Method Trenchless on Road.as per site required direction of Engineer incharge

760

-

-

... More
Digging of Pits Of Size 4 Mtr X 4 Mtr X 1.5 Mtr. For Cable Loop

1

-

-

... More
Restoration of Pit After Laying Of Cable loop

1

-

-

... More
Hoisting of 33 KV 3X300 Sq mm XLPE Cable On Double Pole Structure through GI Pipe 140 MM dia 3 Mtr Long Fixed On Pole Structure Including its Jumpring Complete with Clamps Bolts and

10

-

-

... More
Providing & Fixing and Interconnecting 6 Mtr. Long Pieces of HDPE Pipe shocket.

127

-

-

... More
Laying And Pulling of 33 KV XLPE Cable Off size Throug HDPE Pipe

760

-

-

... More
Laying of 11/33 KV cable with Making open cut method trench as per site required direction of Engineer incharge

1200

-

-

... More
Road Restoration kachha work

120

-

-

... More
Road Restoration Pakka work

340

-

-

... More
Providing of 11 KV Straight Through off size

39

-

-

... More
Fixing of 11 KV Straight Through off size

39

-

-

... More
Providing of 11 KV XLPE Cable Jointing Kit off size

51

-

-

... More
Fixing of 11 KV XLPE Cable Jointing Kit off size

51

-

-

... More
Providing of 33 KV XLPE Cable Jointing Kit off size

19

-

-

... More
Fixing of 33 KV XLPE Cable Jointing Kit off size

19

-

-

... More
The follwing material will be provided AND FIXING by the contractor

-

-

-

... More
HOLDING CLAMP

2132

-

-

... More
CLAMP FOR STP POLE

32

-

-

... More
F CLAMP WITH NUT BOLT

567

-

-

... More
DANGER BOARD

474

-

-

... More
Number Plate

474

-

-

... More
PERCING Clamp

852

-

-

... More
LT CLAMP FOR PCC POLE

230

-

-

... More
SUSPENSION CLAMP FOR LT ABC

872

-

-

... More
DEAD END CLAMP FOR LT ABC

525

-

-

... More
NUT & BOLT

1637

-

-

... More
J HOOK

570

-

-

... More
TF Clamps

25

-

-

... More
MS CHANEL, ANGEL, DROPER,

11357

-

-

... More
STONE PAD

617

-

-

... More
XLPE CABIL SPOTING WIRE

860

-

-

... More
FUSE SET ANGEL/CHANEL

1575

-

-

... More
Dismantling and removing of old VCB

9

-

-

... More
Carrige of all dismantle material site/substation to store center BSR.

36

-

-

... More
400 KVA TF TROLLEY WITH Heavy duty MS FENCING, best quality TYRE including all material as per respo/approve drawing.

2

-

-

... More
Removing of old and damaged stp/pcc pole

-

-

-

... More
cutting of damaged stp pole through gas cutter

25

-

-

... More
removing damaged stp/pcc pole with help of hydra and carrying it to concerned substation

60

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.