North Central Railway Tender

... More
The NCR has issued a formal invitation for competitive bids for the North Central Railway project, for Engineering, Procurement And Construction (epc) Agreement With Schedule G-1 For Third Line Track Between Manikpur (excluding) To Iradatganj (including) (ch: 1257.180 To 1340.820) Including Electrification & Signaling Works Along With Construction Of Rob On Lc No. 404/c2, 406/2t, 407/2e & 418c/2e And Rub In Lc No 426 In Connection With Manikpur-iradatganj 3rd Line Project Of North Central Railway in Kanpur Dehat, Uttar Pradesh, with an estimated contract value of Rs. 12,62,92,89,730. The bid opening date for this tender is 08-07-2026 and the last date for bid submission is 20-11-2026. Interested bidders for North Central Railway tender can download the important documents here to check the scope of work, eligibility criteria and technical requirements.

North Central Railway - NCR Tender - UP Tender

Opening Date8 Jul 2026
Closing Soon20 Nov 2026
Tender Amount₹ 12,62,92,89,730.93 
Notes
Download

Costs

Description

Engineering, Procurement And Construction (epc) Agreement With Schedule G-1 For Third Line Track Between Manikpur (excluding) To Iradatganj (including) (ch: 1257.180 To 1340.820) Including Electrification & Signaling Works Along With Construction Of Rob On Lc No. 404/c2, 406/2t, 407/2e & 418c/2e And Rub In Lc No 426 In Connection With Manikpur-iradatganj 3rd Line Project Of North Central Railway

AI Insights

Unlock AI Insights for this Tender

Sign in to request AI-powered insights, eligibility criteria and automated analysis for this tender.

Contact

Unlock the Tender details

GEM & Bid Advisory Services

Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

Unlock the Tender details
... More
Supply of permanently lubricated HDPE duct, 40 mm outer dia, as per RDSO spec. No. RDSO/SPN/TC/45/2013 Rev.2 Amndt.2 or latest, along with all accessories like end caps, collars, bends, couplers etc. Blowing/drawing of OFC through HDPE duct and protective work already provided in the excavated trench. All the equipments and machinery required shall be arranged by the contractor at his own cost. Cable should be laid according to the technical conditions & instructions of the site incharge.

-

-

25

... More
Excavation of cable trench as per cable route plan, 1.2 Mtr. deep and of 0.3 Mtr. to 0.6 Mtr. wide at bottom as per RDSO sketch No. SDO/CABLE LAYING/003, issued vide RDSO document No. RDSO/SI/G/2010 Version 1.1 dated 04.02.2014 or latest, alongside the track in rocky soil, conforming to distances as per cable route plan and refilling and ramming of loose soil. This 21 work includes clearing of route from bushes etc,covering of cable laid in trench by loose soil for a layer of 50 mm thickness approximately before covering by bricks. The work shall be done as per the extant practice on North Central Railway and instructions of Railway Engineer at site. In case the full depth of trench is not available, there shall be no proportionate payment and after the approval of minimum JAG Officer, the concreting shall be done as per the RDSO Drg. No.SDO/Cable laying/008, issued vide RDSO document No. RDSO/SI/G/2010 version 1.1 dated 04.02.2014 or latest.

8000

64

517520

... More
Supply of Apparatus Case/Location Box Full as per RDSO drg. no.RDSO/S-11500 or 4 latest, with 'E' type lock and key ward no. 42, . The key and handle should be supplied at the rate of one no. per four Apparatus cases. The 'E' type key lock is as per RDSO Spec.No. IRS;S-30/64 or latest, RDSO drg. no.SA 3376/M or latest and Key is as per Drg. No. 3377/M or latest. Inspection by RITES.

40

27499

1099992.4

... More
Supply of permanently lubricated HDPE duct, 40 mm outer dia, as per RDSO spec. No. RDSO/SPN/TC/45/2013 Rev.2 Amndt.2 or latest, along with all accessories like end caps, collars, bends, couplers etc.

9

79379

714414.96

... More
Supply of underground railway jelly filled 6 Quad cable. 0.9 mm dia copper conductor, as per RDSO spec. IRS: TC 30/2005 (Ver.-1) (Amnd. 1 to 5) or latest

15

297404

4461066.75

... More
Supply of Disconnect Terminal block for four conductors with screwing cage/clamp 11 type, sliding switch disconnect, as per RDSO spec. RDSO/SPN/189/2004 Ver. 3.0 or latest, for each conductor size up to 2.5 sq. mm, equivalent of M6 terminals. Each terminal block equipped with two markers, on top and bottom, an end plate, two end clamps and adequate length of rails for fitting terminal blocks. Inspection by RITES.

9000

192

1734480

... More
Installation of thermo shrink jointing kit as per RDSO Specn.No. IRS: TC 77-2012 (Rev.3.0) with (Amdt.-1 to 3) or latest, suitable for 6 Quad/jelly filled cables for straight through/derivation joints. It includes supply of all the accessories, without transformer

60

1713

102802.8

... More
Installation of thermo shrink jointing kit as per RDSO Specn. No. IRS: TC 77-2012 (Rev.3.0) with (Amdt.-1 to 3) or latest, suitable for 6 Quad/jelly filled cables for straight through/derivation joints. It includes supply of all the accessories, without transformer

50

1713

85669

... More
Supplying and placing of one layer of quality bricks of standard size and of 'B' grade of the local make and spreading on cables laid within station limit.(minimum size of brick 200mm X 100mm X 70mm) Inspection by consignee.

96000

4

414720

... More
Termination of Outdoor Cables (Main Cables /tail cables) at ARA/Disconnect type terminals provided in Apparatus Cases, Cable termination rack in relay room, station building, 10 generator room etc. The item includes dressing of cables and wires with dressing threads as per standard practice. All material required for this item will be supplied by contractor. The outdoor cable shall be terminated in Relay Room, DG Room, ASM Room etc. under supervision and instructions issued by Engr. in-charge of the work.( Qty unit : per conductor)

5000

14

73800

... More
Fixing of ARA(M-6) Terminals /Screw less connectors / modular disconnect terminal 8 blocks and fuse blocks on phenolic laminated sheets and fixing by stainless steel/brass nuts & bolts. This includes provision of two additional holes on the board on either side for cable conductor entry. The work shall be carried out a per instructions of railway Engineer in-charge.(Supply of all above terminals has been covered separately).

2500

17

44075

... More
Laying of S&T Cables of various cores/ pairs/ quads in trenches/ GI pipes/ RCC pipes/ DWC pipes etc. as per the site requirement and as per approved cable route plan. This also includes 16 laying of cables in track crossings & road crossings.(Cables will be meggered before and after its laying by contractor under supervision of Railway Representative and he will submit the meggering report of each testing). Length of the cable laid includes the length of the cable coiled for termination purposes.

60000

6

410400

... More
Painting of two coats of Enamel paint over one coat of Red Oxide primer after scrapping and cleaning of the surface. Paint to be of reputed make Asian/Dulux/Berger or similar.App. Cases inside and outside to be done by Silver colour. (Apparatus Case Half)

20

631

12634.6

... More
Fabrication and fixing of phenolic laminated sheet of grade P3, minimum 10 mm thick, as per Apparatus case diagram/plan, in location box by providing all fixtures like 12 ARA/Disconnect terminals, fuse blocks, fuses, relays on square bars etc. including fixing of PVC coated string rods at the back side for cable support with contractor's own material like iron angle, nuts, bolts etc. The iron angle for fixing shall be minimum 3 mm thick. This also includes fixing of teak wood shelf minimum 25 mm thick for holding track circuit equipments. The work shall be done as per instructions of Rly engineer at site. Inspection by Rites. (Apparatus case Half)

10

2428

24281.8

... More
Shifting of existing full location boxes coming in the alignment of new line. The work includes losing & removal of soil around location boxes by excavating soil around foundation , making of pit for shifting of location box horizontally opposite to railway track up to 0.5 to 1.0mtr. 28 This includes loosing of existing cable coils without any damage. The excavated soil shall be back filled after shifting of Location Boxes Location box shall be shifted by push method with the help of jacks or by crane by contractors own expenditure under instructions of engineer in-charge at site. The work may affect train working hence the work shall be done as per margin only or during traffic block only.

15

4369

65548.95

... More
Excavation, casting, curing of foundation and Installation and Erection of Apparatus 8 case Full as per Drg No. AGC/FULL LOC/2023/01 (App. Case as per RDSO drg. no. RDSO/S-11500 or latest) with contractor's own frame, cement and other material in the ratio 1:3:6. 'E' type lock to be supplied and installed with App. case.This includes filling of location foundations with river bed sand and plastering on top with a mixture of 1:4 of cement and sand.

50

12272

613611

... More
Excavation of cable trench as per cable route plan, 1.2 Mtr. deep and of 0.3 Mtr. to 0.6 Mtr. wide at bottom as per RDSO sketch No. SDO/CABLE LAYING/003, issued vide RDSO document No. RDSO/SI/G/2010 Version 1.1 dated 04.02.2014 or latest, alongside the track in rocky soil, conforming to distances as per cable route plan and refilling and ramming of loose soil. This 19 work includes clearing of route from bushes etc,covering of cable laid in trench by loose soil for a layer of 50 mm thickness approximately before covering by bricks. The work shall be done as per the extant practice on North Central Railway and instructions of Railway Engineer at site. In case the full depth of trench is not available, there shall be no proportionate payment and after the approval of minimum JAG Officer, the concreting shall be done as per the RDSO Drg. No.SDO/Cable laying/008, issued vide RDSO document No. RDSO/SI/G/2010 version 1.1 dated 04.02.2014 or latest.

4000

64

258760

... More
Painting of two coats of Enamel paint over one coat of Red Oxide primer after scrapping and cleaning of the surface. Paint to be of reputed make Asian/Dulux/Berger or similar.App. Cases inside and outside to be done by Silver colour. (Apparatus Case Half)

10

631

6317.3

... More
Supply of Disconnect Terminal block for four conductors with screwing cage/clamp 9 type, sliding switch disconnect, as per RDSO spec. RDSO/SPN/189/2004 Ver. 3.0 or latest, for each conductor size up to 2.5 sq. mm, equivalent of M6 terminals. Each terminal block equipped with two markers, on top and bottom, an end plate, two end clamps and adequate length of rails for fitting terminal blocks. Inspection by RITES.

5000

192

963600

... More
Supply of thermo shrink jointing kit as per RDSO Specn.No. IRS: TC 77-2012 (Rev.3.0) with (Amdt.-1 to 3) or latest, suitable for 6 Quad/jelly filled cables for straight through/derivation joints. It includes supply of all the accessories, without transformer

60

3361

201669

... More
Shifting of existing half location boxes coming in the alignment of new line. The work includes losing & removal of soil around location boxes by excavating soil around foundation, 29 making of pit for shifting of location box horizontally opposite to railway This includes loosing of existing cable coils without any damage. The excavated soil shall be back filled after shifting of Location Boxes. Location boxs hall be shifted by push method with the help of jacks or by crane by contractors own expenditure under instructions of engineer in-charge at site. The work may affect train working hence the work shall be done as per margin only or during traffic block

5

3379

16898.6

... More
Supply of thermo shrink jointing kit as per RDSO Specn.No. IRS: TC 77-2012 (Rev.3.0) with (Amdt.-1 to 3) or latest, suitable for 6 Quad/jelly filled cables for straight through/derivation joints. It includes supply of all the accessories, without transformer

30

3361

100834.5

... More
Excavation, casting, curing of foundation and Installation and Erection of Apparatus 9 case Half as per Drg No. AGC/HALF LOC/2023/01 with contractor's own frame, cement and other material in the ratio 1:3:6.'E' type lock to be supplied and installed with App. case.This includes filling of location foundations with river bed sand and plastering on top with a mixture of 1:4 of cement and sand.

20

10324

206483.6

... More
Splicing of 24 core optic fibre cable and making the splicing joint with contractor's 26 own machine and tools. Joint should be prepared in such a way that the top of the enclosure shopuld be at a depth of minimum 1.2 mtr and the enclosure should be covered with soft soil and bricks. Splice loss of each fibre should be less than 0.05 dB.

20

12009

240180.2

... More
Supply of underground railway jelly filled 6 Quad cable. 0.9 mm dia copper conductor, as per RDSO spec. IRS: TC 30/2005 (Ver.-1) (Amnd. 1 to 5) or latest

-

-

4

... More
Supply of 06 Core x 1.5 square mm (copper conductor),PVC insulated, armoured, unscreened, underground railway signalling cable, as per RDSO spec. IRS: S-63/2014 (Rev. 4.0) or latest

2

108378

216757

... More
Supply of Phenolic laminated Sheet, resin bonded, grade P3 in standard size of 1220 X 1220 x 10 mm as per spec. No IS 2036 of 1995 or latest. Test report of manufacture to be supplied. Inspection by consignee.

-

-

15

... More
Supply of 48 fiber Armoured OFC cable as per RDSO PN/TC/110/2020Rev.0 or latest.

-

-

5

... More
Supply of Phenolic laminated Sheet, resin bonded, grade P3 in standard size of 1220 X 1220 x 10 mm as per spec. No IS 2036 of 1995 or latest. Test report of manufacture to be supplied. Inspection by consignee.

50

5827

291356.5

... More
Supply of Medium class GI pipes 100 mm dia (4.5 mm thickness) with thread collars as per IS 1239 (Part 1) 2004 or latest with coupling on culverts/bridges, perforated at a distance of 18 20 cm or less with 10 mm dia hole, or at any other locations as decided by Site Engineer. It includes supply of all material required for fixing arrangement. Contractor will also supply flexible/corrugated HDPE pipe at the end of GI pipe to protect the cables from sharp edges and sudden bends. Inspection by consignee.

250

991

247827.5

... More
Supply of Double Walled Corrugated (DWC) Pipe/duct with associated collars etc. as per RDSO Specification No. RDSO/SPN/204/2011 Ver.1.1 and or latest anti-rodent & anti-oxidant and non flame propagating type in 6 meters straight length and of size 120 mm outer dia,& 103.5 mm 16 inner dia. (The manufacturers, suppliers must produce valid IS license and should be certified under ISO 9000 and shall submit copy of certificate). One coupler with suitable rubber O-ring should be supplied with every 6m of pipe length. (The total quantity of above items is equal to no. of pipes supplied.) DWC pipe shall be marked at every 1 mtr length in such a way that manufacturer's name, vendor name and year of manufacture can be easily identified. Inspection by Rites.

5000

606

3034350

... More
Painting of two coats of Enamel paint over one coat of Red Oxide primer after scrapping and cleaning of the surface. Paint to be of reputed make Asian/Dulux/Berger or similar App. Cases inside and outside to be done by Silver colour. (Apparatus Case Full)

40

673

26930

... More
Supply of 12 Core x 1.5 square mm (copper conductor),PVC insulated, armoured, unscreened, underground railway signalling cable, as per RDSO spec. IRS: S-63/2014 (Rev. 4.0) or latest

62

223756

13872896.8

... More
Splicing of 24 core optic fibre cable and making the splicing joint with contractor's 28 own machine and tools. Joint should be prepared in such a way that the top of the enclosure shopuld be at a depth of minimum 1.2 mtr and the enclosure should be covered with soft soil and bricks. Splice loss of each fibre should be less than 0.05 dB.

30

12009

360270.3

... More
Excavation, casting, curing of foundation and Installation and Erection of Apparatus 7 case Half (App. Case as per NCR drwaing. with contractor's own frame, cement and other material in the ratio 1:3:6.'E' type lock to be supplied and installed with App. case. This includes filling of location foundations with river bed sand and plastering on top with a mixture of 1:4 of cement and sand.

10

10324

103241.8

... More
Supply of 48 fiber Armoured OFC cable as per RDSO SPN/TC/110/2020Rev.0 or latest.

-

-

3

... More
Fabrication and fixing of phenolic laminated sheet of grade P3, minimum 10 mm thick,as per Apparatus case diagram/plan, in location box by providing all fixtures like 14 ARA/Disconnect terminals, fuse blocks, fuses, relays on square bars etc. including fixing of PVC coated string rods at the back side for cable support with contractor's own material like iron angle, nuts, bolts etc. The iron angle for fixing shall be minimum 3 mm thick. This also includes fixing of teak wood shelf minimum 25 mm thick for holding track circuit equipments. The work shall be done as per instructions of Rly engineer at site. Inspection by Rites. (Apparatus case Half)

20

2428

48563.6

... More
Shifting of existing full location boxes coming in the alignment of new line. The work includes losing & removal of soil around location boxes by excavating soil around foundation, making of pit for shifting of location box horizontally opposite to railway track up to 0.5 to 1.0mtr. 30 This includes loosing of existing cable coils without any damage. The excavated soil shall be back filled after shifting of Location Boxes Location box shall be shifted by push method with the help of jacks or by crane by contractors own expenditure under instructions of engineer in-charge at site. The work may affect train working hence the work shall be done as per margin only or during traffic block only.

30

4369

131097.9

... More
Blowing/drawing of OFC through HDPE duct and protective work already provided in 26 the excavated trench. All the equipments and machinery required shall be arranged by the contractor at his own cost. Cable should be laid according to the technical conditions & instructions of the site incharge.

18

17105

307897.38

... More
Supply of 12 Core x 1.5 square mm (copper conductor),PVC insulated, armoured, unscreened, underground railway signalling cable, as per RDSO spec. IRS: S-63/2014 (Rev. 4.0) or latest

20

223756

4475120

... More
Termination of Outdoor Cables (Main Cables /tail cables) at ARA/Disconnect type terminals provided in Apparatus Cases, Cable termination rack in relay room, station building, 12 generator room etc. The item includes dressing of cables and wires with dressing threads as per standard practice. All material required for this item will be supplied by contractor. The outdoor cable shall be terminated in Relay Room, DG Room, ASM Room etc under supervision and instructions issued by Engr. incharge of the work.

9000

14

132840

... More
Horizontal Boring/Manual moling withoutdamage to surface road /track forlaying/isertion of DWC/GI/HDPE pipe. Thebore shall be done at the depth ofminimum 1400 mm 17 from the groundlevel. The ground level shall beconsidered ignoring the bank height ofthe bank of the road. Note:-DWC/HDPE/GI Pipe Supply is not coveredunder this item. Contactor shall provideall material required for work andadequate nos. of labours for proper layingof cables into the bore. Cable shall be laidcautiously so that it should not getdamage due to rough handling &pressure on cable. Payment of boringshall be made only after DWC/HDPE/GIpipe is laid in the bore.

3000

1029

3089820

... More
Blowing/drawing of OFC through HDPE duct and protective work already provided in 24 the excavated trench. All the equipments and machinery required shall be arranged by the contractor at his own cost. Cable should be laid according to the technical conditions & instructions of the site in-charge.

9

17105

153948.69

... More
Horizontal Boring/Manual moling withoutdamage to surface road /track forlaying/isertion of DWC/GI/HDPE pipe. Thebore shall be done at the depth ofminimum 1400 mm 15 from the groundlevel. The ground level shall beconsidered ignoring the bank height ofthe bank of the road. Note:-DWC/HDPE/GI Pipe Supply is not coveredunder this item. Contactor shall provideall material required for work andadequate nos. of labours for proper layingof cables into the bore. Cable shall be laidcautiously so that it should not getdamage due to rough handling &pressure on cable. Payment of boringshall be made only after DWC/HDPE/GIpipe is laid in the bore.

1500

1029

1544910

... More
Supply of Apparatus Case/Location Box Half as per RDSO drg. no.RDSO/S-11507 or 7 latest, with 'E' type lock and key ward no. 42, . The key and handle should be supplied at the rate of one no. per four Apparatus cases. The 'E' type key lock is as per RDSO Spec.No. IRS;S-30/64 or latest, RDSO drg. no.SA 3376/M or latest and Key is as per Drg. No. 3377/M or latest. Inspection by RITES.

20

19904

398093.8

... More
Excavation, casting, curing of foundation and Installation and Erection of Apparatus 6 case Full as per Drg No. NCR drawing (App. Case as per RDSO drg. no. RDSO/S-11500 or latest) with contractor's own frame, cement and other material in the ratio 1:3:6. 'E' type lock to be supplied and installed with App. case. This includes filling of location foundations with river bed sand and plastering on top with a mixture of 1:4 of cement and sand.

40

12272

490888.8

... More
Painting of two coats of Enamel paint over one coat of Red Oxide primer after scrapping and cleaning of the surface. Paint to be of reputed make Asian/Dulux/Berger or similar.App. Cases inside and outside to be done by Silver colour. (Apparatus Case Full)

80

673

53860

... More
Supplying and placing of one layer of quality bricks of standard size and of 'B' grade of the local make and spreading on cables laid within station limit.(minimum size of brick 200mm X 100mm X 70mm) Inspection by consignee.

48000

4

207360

... More
Construction of OFC jointing pit of size 1mx1mx0.6m, using bricks, sand and cement 29 in the ratio 1:3. The thickness of the wall shall be 120 mm. The top cover shall be of concrete of thickness 75 mm with two iron handles on top of it. The pit shall be covered with sand after putting the joint enclosure. All construction material to be supplied by contractor.

35

6256

218967.7

... More
Supply of Double Walled Corrugated (DWC) Pipe/duct with associated collars etc. as per RDSO Specification No. RDSO/SPN/204/2011 Ver.1.1 and or latest anti-rodent & anti-oxidant and non flame propagating type in 6 meters straight length and of size 120 mm outer dia,& 103.5 mm 14 inner dia. (The manufacturers, suppliers must produce valid IS license and should be certified under ISO 9000 and shall submit copy of certificate). One coupler with suitable rubber O-ring should be supplied with every 6m of pipe length. (The total quantity of above items is equal to no. of pipes supplied.) DWC pipe shall be marked at every 1 mtr length in such a way that manufacturer's name, vendor name and year of manufacture can be easily identified. Inspection by Rites.

2500

606

1517175

... More
For Utility Shifting (Electrical)-Total Lumpsum Cost for Modification of 08 Nos. 33KV, 12 Nos. 11kV electrical crossing by under ground cable and shifting of 15 Nos. 11kV electrical LT line & T/F, modification of 220kV TR line & 132kV TR line in view of 3rd line between Manikpur- Iradatganj of North Central Railway. (Details /estimate may be found in tender documents)

-

-

6.2

... More
Shifting of existing half location boxes coming in the alignment of new line. The work includes losing & removal of soil around location boxes by excavating soil around foundation, 31 making of pit for shifting of location box horizontally opposite to railway This includes loosing of existing cable coils without any damage. The excavated soil shall be back filled after shifting of Location Boxes. Location boxes hall be shifted by push method with the help of jacks or by crane by contractors' own expenditure under instructions of engineer in-charge at site. The work may affect train working hence the work shall be done as per margin only or during traffic block

10

3379

33797.2

... More
Supply of Apparatus Case/Location Box Full as per RDSO drg. no.RDSO/S-11500 or 6 latest, with 'E' type lock and key ward no. 42, . The key and handle should be supplied at the rate of one no. per four Apparatus cases. The 'E' type key lock is as per RDSO Spec.No. IRS;S-30/64 or latest, RDSO drg. no.SA 3376/M or latest and Key is as per Drg. No. 3377/M or latest. Inspection by RITES.

60

27499

1649988.6

... More
Fixing of ARA(M-6) Terminals /Screw less connectors / modular disconnect terminal 10 blocks and fuse blocks on phenolic laminated sheets and fixing by stainless steel/brass nuts & bolts. This includes provision of two additional holes on the board on either side for cable conductor entry. The work shall be carried out a per instructions of railway Engineer incharge.(Supply of all above terminals has been covered separately).

5000

17

88150

... More
Laying of S&T Cables of various cores/ pairs/ quads in trenches/ GI pipes/ RCC pipes/ DWC pipes etc. as per the site requirement and as per approved cable route plan. This also includes 18 laying of cables in track crossings & road crossings.(Cables will be meggered before and after its laying by contractor under supervision of Railway Representative and he will submit the meggering report of each testing). Length of the cable laid includes the length of the cable coiled for termination purposes.

120000

6

820800

... More
Supply of Medium class GI pipes 100 mm dia (4.5 mm thickness) with thread collars as per IS 1239 (Part 1) 2004 or latest with coupling on culverts/bridges, perforated at a distance of 20 20 cm or less with 10 mm dia hole, or at any other locations as decided by Site Engineer. It includes supply of all material required for fixing arrangement. Contractor will also supply flexible/corrugated HDPE pipe at the end of GI pipe to protect the cables from sharp edges and sudden bends. Inspection by consignee.

500

991

495655

... More
Supply of Apparatus Case/Location Box Half as per RDSO drg. no.RDSO/S-11507 or 5 latest, with 'E' type lock and key ward no. 42, . The key and handle should be supplied at the rate of one no. per four Apparatus cases. The 'E' type key lock is as per RDSO Spec.No. IRS;S-30/64 or latest, RDSO drg. no.SA 3376/M or latest and Key is as per Drg. No. 3377/M or latest. Inspection by RITES.

10

19904

199046.9



Evaluation Notes How It Works ?

Related Tenders

Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.