North Central Railway Tender

... More
The NCR has issued a formal invitation for competitive bids for the North Central Railway project, for (a) S&t Work In Connection With Construction Of Rob In Lieu Of Lc No.49a (spl.) At Railway Km 942/17-19 In Fatehpur Railway Station Yard On Pryj- Cnb Section, (b) Construction Of 2 Lane Rob In Lieu Of L-xing No. 19 At Km 203/0-2 On Car-cpu Section, (c) Construction Of Fob With Stair For Pedestrian (grade Separator) At Km 758/5 In Between Jia - Gae Section And (d) Provision Of 12 M Wide A New Fob At Km No. 168.20 At Sonbhadra (sbdr) Station In Car-cpu Section Under Amrit Bharat Scheme Of Prayagraj Division. in Fatehpur, Uttar Pradesh, with an estimated contract value of Rs. 1,46,91,047. The bid opening date for this tender is 21-05-2024 and the last date for bid submission is 20-06-2024. Interested bidders for North Central Railway tender can download the important documents here to check the scope of work, eligibility criteria and technical requirements.

North Central Railway - NCR Tender

Goods
Civil And Construction
Bridge Construction
Ireps
Opening Date21 May 2024
Closing Date20 Jun 2024
Tender Amount₹ 1,46,91,047.4 
Notes
Download

Costs

Summary

(a) S&t Work In Connection With Construction Of Rob In Lieu Of Lc No.49a (spl.) At Railway Km 942/17-19 In Fatehpur Railway Station Yard On Pryj- Cnb Section, (b) Construction Of 2 Lane Rob In Lieu Of L-xing No. 19 At Km 203/0-2 On Car-cpu Section, (c) Construction Of Fob With Stair For Pedestrian (grade Separator) At Km 758/5 In Between Jia - Gae Section And (d) Provision Of 12 M Wide A New Fob At Km No. 168.20 At Sonbhadra (sbdr) Station In Car-cpu Section Under Amrit Bharat Scheme Of Prayagraj Division.

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Dismantling and Releasing of existing Location boxes/Apparatus cases/Jn boxes and other associated S&T fittings. All the released material will be transported to the SSE/Consignee depot. INSP.By- Consignee

13

972

12637.04

... More
Supply and installation of earth electrode as per standard practice and as per NCR Drawing no. S&T/CONST/6.4/97. It includes supply of GI pipe of 3m length. It includes connecting the earth electrode to the equipments which are required to be earthed including digging of earth pit 3 mtr deep and fixing earth electrode 26 pipe, casting of cement concrete enclosure with cover (cover as per drawing no. S&T/CONST/6.3/97. It includes installation of GI MS strip 25x5 mm, supported on MS flat size 5mm x 40 mm, soldering and nut bolt both, one end of both earth lead wire and MS flat to earth electrode and other end to Location boxes, block equipments, power equipments, cable sheath, signals etc. as per site requirement and as per instructions given by engineer incharge. INSP.By-Consignee

13

2422

31488.86

... More
Supply of Non deteriorating type, Round head type, low voltage cartridge fuse as per Spec No IRS: S -78/92 with latest amendments, 2A/4A/6A/8A/10A rating capacity. INSP.By-RDSO

557

86

48169.36

... More
Excavation, casting, curing of foundation and Installation and Erection of Apparatus case Full 15 (Apparatus Case as per RDSO drg. No. RDSO/S-11500 or latest) with contractor's own frame, cement and other material in the ratio 1:3:6. 'E' type lock to be supplied and installed with Apparatus case. This includes filling of location foundations with river bed sand and plastering on top with a mixture of 1:4 of cement and sand. It covers fixing of lamp holder, switch and lamp etc. in Apparatus Case. INSP.By-Consignee

17

8617

146502.09

... More
Supply of 16/0.2 mm (0.5 sq mm) PVC insulated multi strand, single core, tinned copper conductor, as per RDSO Specn.No.IRS:S-76/89 (Amnd-3) or latest. Each coil should be of 100/200/500 meters length.Colour of the wire will be specified by the Engineer incharge. INSP.By-Consignee

4159.21

7

31776.38

... More
Laying of HDPE duct as per the approved cable route plan in the excavated trenches/other protected works/RCC channel etc. including all accessories like end caps, collars, bends, couplers etc. The ends 7 of the duct to be sealed with end plugs till OFC blowing is done. Important: The laying of OFC cable independently or along with Quad cable/PIJF cable in the same trench shall be governed by the RDSO drawings No. RDSO/TCDO/COP-6(a) and RDSO/ TCDO/COP-8 (a) respectively, issued vide Chapter-XIII of the Telecomm Manual. INSP.By-Consignee

6

6654

39925.56

... More
Painting of two coats of Enamel paint over one coat of Red Oxide primer after scrapping and cleaning of the surface. Paint to be of reputed make Asian/Dulux/Berger or similar.App. Cases inside and outside to be done by Silver colour. (Apparatus Case Full) INSP.By-Consignee

17

509

8664.73

... More
Lettering and Numbering of all S&T gears like Signals, Loc. Boxes, Pt. Machines, TLJBs, Block joints etc. Each item to be taken as one unit. INSP.By-Consignee

13

63

831.61

... More
"Supply of Double Walled Corrugated (DWC) Pipe/duct with associated collars etc. as per RDSO Specification No. RDSO/SPN/204/2011 or latest anti-rodent & anti-oxidant and non flame propagating type in 6 2 meters straight length and of size 120 mm outer dia,& 103.5 mm inner dia. (The manufacturers, suppliers must produce valid IS license and should be certified under ISO 9000 and shall submit copy of certificate). One coupler with suitable rubber O-ring should be supplied with every 6m of pipe length. (The total quantity of above items is equal to no. of pipes supplied.)DWC pipe shall be marked at every 1 mtr length in such a way that manufacturer's name, vendor name and year of manufacture can be easily identified. INSP.By-RITES"

2200

490

1079628

... More
Supply of 24 fiber optical fiber cable straight joint enclosure (SJC) complete with all accessories along with enclosures with heat shrinkable splice protection sleeve as per RDSO spec. RDSO/SPN/TC-68/2014 Revision 1.0, Amndt. 1.0 or latest. Splice losses in no case should be more than 0.1 dB. INSP.By-Consignee

14

4452

62330.52

... More
Laying of S&T Cables of various cores/ pairs/ quads in trenches/ GI pipes/ RCC pipes/ DWC pipes 5 etc. as per the site requirement and as per approved cable route plan. This also includes laying of cables in track crossings & road crossings.(Cables will be meggered before and after its laying by contractor under supervision of Railway Representative and he will submit the meggering report of each testing). Length of the cable laid includes the length of the cable coiled for termination purposes. INSP.By-Consignee

54000

5

276480

... More
Supply of thermo shrink jointing kit as per RDSO Specn.No. IRS: TC 77-2012 (Rev.3.0) with (Amdt.- 1 to 3) or latest, suitable for 6 Quad/jelly filled cables for straight through/derivation joints. It includes supply of all the accessories, without transformer. INSP.By-RDSO

16

2718

43489.76

... More
Fabrication and fixing of phenolic laminated sheet of grade P3, minimum 10 mm thick,as per Apparatus case diagram/plan, in location box by providing all fixtures like ARA/Disconnect terminals, fuse blocks, 16 fuses, relays on square bars etc. including fixing of PVC coated string rods at the back side for cable support with contractor's own material like iron angle, nuts, bolts etc. The iron angle for fixing shall be minimum 3 mm thick. This also includes fixing of teak wood shelf minimum 25 mm thick for holding track circuit equipments. The work shall be done as per instructions of Rly engineer at site. (Apparatus case Full) INSP.By-Consignee

17

3143

53438.48

... More
Supply of Cartridge Fuse block, made of PBT, as per RDSO spec. No. IRS: S-75/2006 (Rev.2) or latest and as per Drawing. No. SA- 23748 (Alt.-4) or latest. INSP.By-RDSO

432

171

73884.96

... More
Supply of ARA terminal block, made of PBT, as per RDSO spec. No. IRS: S-75/2006 (Rev.2) or latest and as per Drawing. No. SA- 23741A (Alt.-4) or latest. INSP.By-RDSO

2200

91

201806

... More
Signal maintainer Tool Kit as per specification attached (Annexure-C). Each tool kit consist of 4 items that are follows: 1. Digital Insulation and continuty tester. 2. Smart AC/DC leakage clamp meter. 3. Digital Earth tester. 4. True RMS.Digital multimeter. INSP.By-Consignee

6

71335

428014.32

... More
Supply of straight joint enclosures (SJC) complete with all accessories with latest amendments or Raychems RPG make FOSC-400-B4-A-BJL-4-H -48 or similar make only.(For 48 fiber OFC) and splicing of 2X48 F OFC. INSP.By-Consignee

26

17116

445030.56

... More
Blowing/drawing of OFC cable in the HDPE pipe duct and protective work already provided in the 23 trench. Th e cable shall be laid only after the successful completion of the DIT (Duct Integrity test). The DIT should be certified by the Railway engineer at site. All the equipments/machinery required shall be arranged by the contractor. INSP.By-Consignee

8

14055

112444.96

... More
Splicing of 24 core optic fibre cable and making the splicing joint with contractor's own machine and 13 tools. Joint should be prepared in such a way that the top of the enclosure should be at a depth of minimum 1.2 meter and the enclosure should be covered with soft soil and bricks. Splice loss of each fibre should be less than 0.05 dB. INSP.By-Consignee

16

10318

165089.44

... More
Supply of Phenolic laminated Sheet, resin bonded, grade P3 in standard size of 1220 X 1220 x 10 mm as per spec. No IS 2036 of 1995 or latest. Test report of manufacture to be supplied. INSP.By-Consignee

17

4653

79115.28

... More
Modification/Alteration in existing EI (Electronic Interlocking) as per latest RDSO guidelines/TAN. It includes: Design and modification in existing Interface and Interlocking circuits and logic of EI system including modification in the VDU(Video Display Unit)/ LCP(Local Control panel)/ CCIP (Control cum Indication Panel), Maintenance terminal (MPC), Data Logger, Relay rack wiring. The complete work should comply with the latest 32 RDSO specifications and guidelines and as per approved SIP and circuit diagrams. All the material (Interface cards/relays/wiring material/ connectors /fuses/ communication devices etc.) shall be provided by the contractor.The work also includes the supply of modified Selection table, Interface Circuits, VDU/LCP/CCIP diagram etc. to suit the modified SIP. It also includes the carrying out of FAT, SAT (as applicable) jointly with Railways and satisfactory commissioning. All plans/drawings/circuits etc. should be prepared on AUTOCAD, softcopy to be supplied on Pen Drive and 06 sets of hard copies also to be supplied. INSP.By-Consignee

2

1204497

2408995.24

... More
Excavation of cable trench as per cable route plan, 1.2 Mtr. deep and of 03 Mar. to 0.6 Mt. wide at bottom as per RDSO sketch No. SDO CABLE LAYING 003, issued vide RDSO document No. RDSO/SL/G/2010 Version 1.1 dated 04.02.2014 or latest, alongside the track in normal (all type) soil strata, conforming to distances 1 as per cable route plan and refilling and ramming of loose soil. This work includes clearing of route from bathes etc,covering of cable laid in trench by loose soil for a layer of 50mm thickness approximately before covering by bricks. The work shall be done as per the extant practice on North Central Railway and instructions of Railway Engineer at site. In case 1.2m depth of trench is not achievable due to site conditions, specific approval of JAG/SG Officer will be required for each site where trench depth of 1.2m is not possible, only after approval of JAG/SG Officer proportionate payment can be done. INSP.By-Consignee

6000

70

425760

... More
Supply of Medium class GI pipes 100 mm dia (4.5 mm thickness) with thread collars as per IS 1239 34 (Part 1) 2004 or latest with coupling on culverts/bridges, perforated at a distance of 20 cm or less with 10 mm dia hole, or at any other locations as decided by Site Engineer. It includes supply of all material required for fixing arrangement. Contractor will also supply fl exible/corrugated HDPE pipe at the end of GI pipe to protect the cables from sharp edges and sudden bends. INSP.By-Consignee

250

813

203285

... More
Supply of Apparatus Case/Location Box Full as per RDSO drg. no. RDSO/S-11500 or latest, with 'E' type lock and key ward no. 42, . The key and handle should be supplied at the rate of one no. per four Apparatus cases. The 'E' type key lock is as per RDSO Spec. IRS;S-30/64 or latest, RDSO drg. no.SA 3376/M or latest and Key is as per Drg. No. 3377/M or latest. Note: This item includes the supply of 2 Nos E Type Lock fitted on both doors, along with two Keys. INSP.By-Consignee

13

19310

251041.18

... More
Modification to existing drawings for stns. provided with Level Crossing gate MACLS such as circuit diagram, cable route plan, cable core chart, power supply diagram, Signal lamp/LED card, battery history card etc. 36 inter connection drawing with Relay Room and Equipment room etc. Locking table and dog chart on the basis of approved signalling plan. Square sheet, modification/preparation of cable termination chart in Relay Room and Apparatus Cases, Apparatus cases Wiring Plan, Cable Insulation chart, Earth resistance chart, circuit route termination chart, equipment dispostion plan , Fuse analysis chart, terminal analysis and contact analysis plans, Station Working Rule Diagram (SWRD), SWR PD, etc. INSP.By-Consignee

1

45822

45822.42

... More
Supply and placing of trunking and capping (RCC Duct) of 500mm Width as per Drg.No.SDO/Cable laying/007 (Annexure-10),as detailed in document No.RDSO/SI/G/2010 Ver.1.1 or latest on 'Guidelines on 38 signalling cable laying, with the following modification Note: "The bottom thickness increased from 30mm to 40mm duly retaining overall height of 235 mm from ground level by keeping middle partition wall height at 195 mm from top surface of bottom wall of trunking and also to provide 3 nos long steel rods to make reinforcement design of capping to have improvement strength of capping. INSP.By-RITES

1000

1546

1546380

... More
Cement concrete work for miscellaneous, unscheduled items in ratio 1:3:6 of cement, coarse, sand 31 and aggregate Item includes excavation, ramming of CC by using vibrator, curing and plastering with cement and sand mixture in ratio 1:4 (aggregate will not exceed beyond 3.8 cm). The aggregate cement and sand will be supplied by contractor. INSP.By-Consignee

60

3691

221482.8

... More
Horizontal direction drilling (HDD)/Trenchless digging/machine drilling with-out damage to surface road /track for laying/insertion of HDPE/GI/DWC pipe. The bore shall be done at the depth of minimum 1400 mm 4 from the ground level. The ground level shall be considered ignoring the bank height of the bank of the road. Note:- DWC/HDPE/GI Pipe Supply is not covered under this item. Contactor shall provide all material required for work and adequate nos. of labours for proper laying of cables into the bore. Cable shall be laid cautiously so that it should not get damage due to rough handling & pressure on cable. Payment of boring shall be made only after DWC/HDPE/GI pipe is laid in the bore. INSP.By-Consignee

3200

529

1694208

... More
Supply and testing of Integrated cable route tracer and RFID marker locator of reputed make, 3M or similar. INSP.By-RITES

2

429429

858858.76

... More
Supply of paints, primers,varnish and other painting material, complete painting and varnishing , 39 lettering, numbering of all signalling gears, including signal posts and fittings, apparatus cases, point machines, junction boxes, signal machine, rail post, other gears etc. complete at a station/mid section gates/huts, letter writing on terminal Nos. apparatus cases, point machine, Signal Nos. and other details as per S.E.M., instructions of Engineer at site and as per Technical specifications. (station/yard) INSP.By-Consignee

1

72637

72637.53

... More
Horizontal Boring/Manual moling without damage to surface road /track for laying/isertion of 3 DWC/GI/HDPE pipe. The bore shall be done at the depth of minimum 1400 mm from the ground level. The ground level shall be considered ignoring the bank height of the bank of the road. Note:- DWC/HDPE/GI Pipe Supply is not covered under this item. Contactor shall provide all material required for work and adequate nos. of labours for proper laying of cables into the bore. Cable shall be laid cautiously so that it should not get damage due to rough handling & pressure on cable. Payment of boring shall be made only after DWC/HDPE/GI pipe is laid in the bore. INSP.By-Consignee

2500

760

1900900

... More
Supply of permanently lubricated HDPE duct, 40 mm outer dia, as per RDSO spec. No. RDSO/SPN/TC/45/2013 Rev.2 Amndt.2 or latest, along with all accessories like end caps, collars, bends, couplers etc INSP.By-Consignee

6

63162

378972.18

... More
Installation of thermo shrink jointing kit as per RDSO Specn.No. IRS: TC 77- 2012 (Rev.3.0) with (Amdt.-1 to 3) or latest, suitable for 6 Quad/jelly filled cables for straight through/derivation joints. It includes supply of all the accessories, without transformer. INSP.By-Consignee

16

1360

21769.6

... More
Excavation of cable trench as per cable route plan, 1.2 Mtr. deep and of 0.3 Mtr. to 0.6 Mtr. wide at bottom as per RDSO sketch No. SDO/CABLE LAYING/003, issued vide RDSO document no. RDSO/SI/G/2010 Version 1.1 dated 04.02.2014 or latest, alongside the track in normal soil/strata (including soft rock), conforming to distances as per cable route plan and refilling and ramming of loose soil. This work includes clearing of route from 37 bushes etc, covering of cable laid in trench by loose soil for a layer of 50mm thickness approximately before covering by bricks. The work shall be done as per the extant practice on North Central Railway and instructions of Railway Engineer at site. In case the full depth is not available, there shall be no proportionate payment and after the approval of minimum JAG officer, the concreting shall be done as per the RDSO drawing no.SDO/Cable laying/008, issued vide RDSO document no. RDSO/SI/G/2010 Version 1.1 dated 04.02.2014 or latest. INSP.By- Consignee

2000

48

96580

... More
Frequency selective voltmeter, Model- FSV-02 MAKE Aplab or equivalent, TO be supplied after prior approval of railway. INSP.By-Consignee

2

122720

245440



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.