Madhyanchal Vidyut Vitran Nigam Limited Tender

... More
The MVVNL has issued a formal invitation for competitive bids for the Madhyanchal Vidyut Vitran Nigam Limited project, for 17/eucc-v/lesa/2024-25 in Lucknow, Uttar Pradesh, with an estimated contract value of Rs. 22,89,000. The bid opening date for this tender is 14-01-2025 and the last date for bid submission is 20-01-2025. Interested bidders for Madhyanchal Vidyut Vitran Nigam Limited tender can download the important documents here to check the scope of work, eligibility criteria and technical requirements.

Madhyanchal Vidyut Vitran Nigam Limited - MVVNL Tender

Works
Civil And Construction
Electrical and Electronics
Water Storage And Supply
Electrical Works
Eprocure
Opening Date14 Jan 2025
Closing Date20 Jan 2025
Tender Amount₹ 22,89,000 
Notes
Download

Costs

Summary

17/eucc-v/lesa/2024-25

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
MS Channel 125x65mm 3.5m long 2 Nos. 7M @ 13.1 Kg. Mtr.

210

-

-

... More
MS Round of 32 mm dia for laying of main earthmat in switch yard & for panel earthing bridge 550m@6.21 Kg./M

1000

-

-

... More
Return balance material to LESA store daliganj and other work in site area

1

-

-

... More
Erection, commissioning and Testing of 05 MVA T/F mounting of radiator conservator tank exposure vent etc. Filling of T/F oil in radiator conservator tank with complete work as per RESPO Norms.

1

-

-

... More
Dragging of following panels (Control and feeder pannel) from unloading place upto control room and placement erection and grouting, commissioning & testing of the same as per RESPO Norms

-

-

-

... More
M S Earthing Rod 20x2500 mm

4

-

-

... More
Laying of copper control cable of following sizes its proper dressing ,ferruling and connection with the system as per Site Condition with cleaning of Existing Trench. ( except control cable all the material shall be provided by contractor) as per norms

-

-

-

... More
M.S.channel 100x50 sq mm

130

-

-

... More
Laying of Single circuit 11 KV 3x185 sq mm XLPE cable in normal soil/already Constructed trench/As per Site Condition by digging of suitable size of trench as per site condition cable should be covered by bricks and sand with cleaning of Existing Trench.

160

-

-

... More
11 KV Incoming VCB 600/300/5A, 350 MVA

1

-

-

... More
11 KV 3x185mm2 Outdoor Termination Kit

2

-

-

... More
M.S.Channel 125x65x6 mm

60

-

-

... More
33 KV lightning Arrestors

3

-

-

... More
Construction of Control cable trench of size 150 mm wide 300 mm deep with brick work along with provision trench cover M.S strip at the interval of 0.30 M and M.S angle at both the edge of the trench.

80

-

-

... More
ST pole 11 mtr long

4

-

-

... More
Mounting of accessories/equipment on fabricated structure complete work with making proper alignment and tightening the work includes fabrication work if required for proper operation of equipment .

-

-

-

... More
Isolator Structure-Fabrication of Isolator structure minimum 3.5 mtr overall height and 2.5 mtr above ground level as per RESSPO drawing, with help of M.S channel 125x65 mm two pieces of M.S channel joined to each other by M.S flat 50x6 mm, diagonally at the interval of 0.5 mtr and top & bottom of the structure. Grouting of Isolator structure in CC (cement ,coarse sand and stone grit of 20 mm gauge) including supply of necessary T&P and painting os structure complete.(only M.S channel and angle provided by the deptt)

2

-

-

... More
Cutting ,fabrication and driving of earth electrode of size 32x3000 mm

20

-

-

... More
33 KV T/F Control panel

1

-

-

... More
Provided NOC from Electrical Safety department befor Energization of 5 MVA Transformer. (The amount willl be reimbursed as per actual expenditure/receipt issued by concerned department upto maximim limit of Rs. 50000.00)

1

-

-

... More
11 KV 3x185mm2 Indoor Termination Kit

2

-

-

... More
Jumpering complete Line bay with ACSR panther Cond. and required clamp with nut & Bolts from 33KV existing bus bar to cable stand & other all required work. ( Except Panther Conductor all required material provided by Contractor.)

1

-

-

... More
Earthing of substation Switchyard complete by round bar 32 mm dia exavation of earth for laying of earth mat 750mm deep and proper leveling after laying of earth mat Complete as per specification and connecation of all switchyard equipment by GI Flat 50x6 mm (The contractor shall arrange all the material except MS Round Bar 32 MM)

1

-

-

... More
33 KV Control Pannel single circuit Transformer

1

-

-

... More
M.S. Angle 65x65x6 mm

60

-

-

... More
Copper Control Cable 4x2.5 Sq. mm.

300

-

-

... More
Earthing of substation Switchyard.

-

-

-

... More
Painting of all structures equipment.

1

-

-

... More
M.S.Angle 65x65x6 sq mm

100

-

-

... More
PG Clamp Panther

30

-

-

... More
11 kv pin insulator

12

-

-

... More
11 kv pin with nut

12

-

-

... More
Supply and installation of fire extinguisher Co2 type 4.5 Kg at suitable place as per RESPO Norms

4

-

-

... More
11 KV Outgoing VCB 200/100/5A, 350 MVA

2

-

-

... More
Laying of Double circuit 11 KV 3x300 sq mm XLPE cable in normal soil/allready Constructed trench/As per Site Condition by digging of suitable size of trench as per site condition cable should be covered by bricks and sand with cleaning of Existing Trench.

60

-

-

... More
Erection of structures, grouting, plinthing of ALL structures equipment.

1

-

-

... More
11 KV 3x300mm2 Indoor Termination Kit

2

-

-

... More
Disc Fitting Suitable for Panther

6

-

-

... More
33 KV VCB

1

-

-

... More
11 KV Bus Coupler

1

-

-

... More
MS Angle 75x75x6 mm

50

-

-

... More
Hoisting of 11KV 3X185 sqmm XLPE cable on double pole with MS pipe/GI pipe of size 5/6" dia 3 M long including its jumpering complete with clamps, nuts and bolts(all material arranged by contractor).

2

-

-

... More
33 KV Lightening Arrester

3

-

-

... More
MS Angle 75x75x6, 2.6M 2 Nos Total 5.2@6.8 Kg./M with wastage

96

-

-

... More
MS Round of 32mm dia for making MS earth electrode 32x3000mm. 78No.x3.0M@6.21 Kg./M

250

-

-

... More
Battery charger 24 Volt

1

-

-

... More
Construction and fixing of trench cover0.5 M wide 0.75 mm thick with cement, coarse sand & stone grit in ratio 1:2:4 for covering of cable trench150 mm wide with provision of M.S Angle as per RESPO Norms

160

-

-

... More
33 KV Bus Isolator

2

-

-

... More
Copper Control Cable 4x2.5 Sq. mm.

300

-

-

... More
ACSR Panther Conductor for Jumpering

70

-

-

... More
Hoisting, jumpering, clamping of 11KV 3x300 sq mm XLPE cable on cable stand, panel with proper taping with the help of empire tape. PVC tape and connectors.

2

-

-

... More
33KV Current Transformer 200/100/1

3

-

-

... More
Construction of masonry type plinth for 33KV VCB of size 1.6x1.6x1 M brick, sand, cement and stone grit including grouting of 4 Nos foundation Bolts for erection of 33KV VCB.

1

-

-

... More
33 KV VCB 800 Amp. 750 MVA

1

-

-

... More
Hoisting, jumpering, clamping of 11KV 3x185 sq mm XLPE cable on 11 KV panels with proper taping with the help of empire tape. PVC tape and connectors.

2

-

-

... More
MS channel 100x50 mm

90

-

-

... More
11 KV 3x300mm2 Outdoor Termination Kit

2

-

-

... More
11 KV 3x185mm2 XLPE Cable

200

-

-

... More
Copper Control Cable 2x2.5 Sq. mm.

150

-

-

... More
MS Channel 125x65mm 3.5m long 4 Nos Pieces 14M@13.1 Kg. Mtr. With wastage

410

-

-

... More
Interloking Soling and gravels in switch yard as per Norms.

500

-

-

... More
Fabrication & Erection of cable stand made of two nos MS channel 100x50x3 mtr. Long jointed to each other by means of 05 nos MS strip 50x6 mm of size 150 mm Long each by welding at equal distance interval as per norms and grouting in block of 300x300x700 completely providing two nos cable clamp also.(All materials will provide by contractor except MS channel).

1

-

-

... More
Extension of 33 kV Bus Bar Gantary complete with structure and other required work. (Except rail/angle/channel/panther conductor all required materials provided by contractor)

1

-

-

... More
Battery set 24 Volt

1

-

-

... More
Lightning Arrestor/ CT structure : - Fabrication of lightning arrestor/CT structure as per RESSPO drawing with the help of 2 nos M.S channel 125x65 mm minimum 3.5 mtr long grouting 1 mtr deep from ground level in cc in ratio 1:4:8. complete in all respect.

2

-

-

... More
CT 200/100/1-A

3

-

-

... More
Rabber mat 2x1.5 Mtr.

4

-

-

... More
Copper Control Cable 2x2.5 Sq. mm.

150

-

-

... More
Cutting shaping, laying and welding of riser strip size 50x6mm G.I strip of size 50x6 mm in between earth mat and equipments /structure/body of T/F for earthing (two nos Riser for each structure equipment individually GI strip shall be provided contractor )

250

-

-

... More
Bus/Line Isolator

2

-

-

... More
11 KV 3x300mm2 XLPE Cable

150

-

-

... More
Dragging, loading, carriage and unloading of following store materials with proper stacking from ESC Daliganj to JE dumps store and from JE dump store to work site.

-

-

-

... More
MS Angle 75x75x6 2.6M long 2 Nos. 5.2@6.8 Kg./M

96

-

-

... More
Jumpering complete T/F bay with ACSR panther Cond. and required clamp with nut & Bolts from 33KV existing bus bar to T/F & other all required work. ( Except Panther Conductor all required material provided by Contractor.)

1

-

-

... More
High Pressure Testing

2

-

-

... More
Fabrication & erection of 11 KV cable exposure type double pole with the provission of cable with fixing of necesory clamps and other acessories like danger board,number plate,barbed wire,2 no. channels 100x50 mm (1600mm each),1 no.MS channel 100x50mm(3200mm in length) for supporting the hoisting of cable & poles.its jumpering by single core PVC aluminium cable with proper size Al.lug after making three phase busbar with help of 11 KV pin,pin insulator and PVC cable. (all material arranged by contractor except steel,pole & insulator).as per RESPO norms.

2

-

-

... More
Earthing of Indoor Equipment by making of 2 Nos. Quard of round bar 32 mm dia as per norms.

1

-

-

... More
Erection of 24 V batteries set with charger including stand (except 24 V batteries set with charger all the material & stand shall be provided by contractor) & initial charging complete set.

1

-

-

... More
Fabrication & Erection of Neutral Stand structure with foundation

1

-

-

... More
Construction of Power T/F plinth suitable for 33/11KV 05 MVA power T/F of size 4x3x1.3 having 0.4 mtr height above ground level. The work includes excavation of foundation base concreting in cc ratio 1:6 M as 12 1st class brick work in ratio 1:4 with coarse sand ,foundation cc in ratio 1:4:8 using M.S bar of 12 mm dia for reinforcement the work includes laying of 2 nos rail pieces 4 mtr long as per drawing/practice the plinth shall be finished in all respect. (only rail piece and M.S angle provided by the department)

1

-

-

... More
Provide bucket with bucket stand as per norms (3nos bucket for sand & 3 nos bucket for water in one set.)

2

-

-

... More
Disc Insulator Suitable for Panther

6

-

-

... More
11 KV Out going VCB 200/100/5A

2

-

-

... More
Rail 105 lb 9 mtr long

936

-

-

... More
Pipe boring type earthing minimum 20 mtr deep from ground level or upto water level with B class G.I. pipe 2 " dia. Connection of equipment with earthing by GI strip 50x6 mm included in the job as per specification/norms for power transformer, VCB, CT/LA and other. (All materials will be Provided by contractor)

10

-

-

... More
Supply of following auxiliary material

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.