Jhansi Development Authority Tender
If you're a registered bidder for etender UP and want to inquire about any e-tender UP government has posted, this is your stop. No need to enter every detail on the website of <a href="https://etender.up.nic.in">etender.up.nic.in</a> - BidAssist filters will help you find the exact UP etender you're looking for. Read to learn how to search & bid for etender UP.
Jhansi Development Authority - JDA Tender
Machinery and Tools
Eprocure
Opening Date24 Jan 2019
Closing Date2 Feb 2019
Tender Amount₹ 56,58,146
Costs
EMD
₹ 1,13,163Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2019_UPJDA_298766_1Bid Award Id
ViewTender No
2092/JDA/Ni.Su/18-19Tender Authority
Jhansi Development Authority ViewPurchaser Address
-Website
http://etender.up.nic.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
(o) 120 Sqmm 3.5 core (501-507)
375
245250
654
(j) 25 Sqmm 3.5 core (501-507)
475
96425
203
(i) 16 Sqmm 4 core (501-507)
120
20760
173
(h) 10 Sqmm 4 core (501-507)
360
56520
157
(b) 10 Sqmm 2 core (501-507)
150
18300
122
(a) 6 Sqmm 2 core (501-507)
1200
127200
106
Supply and fixing of brass nickle plated compression Gland for PVC insulated and armoured sreved sheathed underground cable including Rubber ring etc complete in all respect the armouring of the cable shall be properly Connected with the earth as per direction of E/I.
(p) 150 sqmm 3.5 core SI No. 503
2
610
305
(o) 120 Sqmm 3.5 core
1
243
243
(j) 25 Sqmm 3.5 core
2
246
123
(i) 16 Sqmm 4 core
2
174
87
(h) 10 Sqmm 4 core
2
174
87
(b) 10 Sqmm 2 core
2
160
80
(a) 6 Sqmm 2 core
2
152
76
Supply and fixing of Plane or Pin type Copper tin plated cable socket lugs to the cable leads, insulating with the tape and making connection etc complete in all respect as per direction of E/I (k) 150 sqmm SI No. 504
8
1168
146
(j) 120 Sqmm
8
936
117
(e) 25 Sqmm
32
864
27
(c) 10 Sqmm
16
320
20
(b) 6 Sqmm
600
10800
18
Supply & laying of 3 core standard alluminium conductor XLPE insulated PVC bedded, galvanized flat steel strip armoured cables confirming to IS 709 (part II with latest amendement) 11 KV grade at a depth of 900 mm. below ground level over a cushion of 100 mm thick find weaver sand all around and protected with well burnt bricks on side and on top put across. the armouring of cable shall be properly connected with earth conductor by clamps etc..as per direction of E/I
70 sqmm 3 core SI No. 506(A)
100
126300
1263
S/E of Factory Fabricated and wire metal clad dust and vermin proof floor mounting, MS channel based with bottom and top cable entries electrical control panel with TPN MCCB's (four pole 36 KA with thermal magnetic relays) switches complete and instrument chamber etc complete in all respect. the instrument chamber shall be seperate and shall comprise of flush type digital metering system for face to face voltage and single face voltage, current and other parameters (KVA, PF, KW etc) in each face with touch type selector switches for different readings, instrument fuses, CT etc. the panel board shall have suitable capacity electrolytic alluminium bus bars as per IS 8623 or above insulated with heat shrink sleeving and mounted on non hygroscopic Supports such as CMC/BMC Support with detachable side cover and shall be suitable for extension on sides. the MCCB's shall be complete with suitable cable end boxes, compression glands and indicating lamp on incoming etc. the job includes the grounting on the board as per direction of E/I. all Outgoings of 100 Amp and above shall have an Ammeter. the panel board shall be fabricated with CRCA sheat with a minimum thickness of 1.6 mm/2 mm. Cubical type switch board shall be of CAT - A&B only.
(C) Incoming
200 Amp MCCB's -1No
Outgoing
100 Amp MCCB -1 No & 63 amp MCCB 3 Nos.
CAT - B Panel cubical type SI NO. 812
2
276140
138070
S/F surface/ flush mounting 8 ways SPN distribution board with additional metal door without MCB complete in all respect as directed by E/I CAT - A SI NO. 1024(A)
4
7600
1900
S/F surface/ flush mounting 6 ways TPN distribution board with additional metal door without MCB complete in all respect as directed by E/I CAT - A SI NO. 1027(A)
3
13110
4370
S/F of 0.5 Amp to 5 amp SP MCB (10 KA) C Curve CAT - A SI NO. 1001
60
22080
368
S/F of 6 Amp to 32 amp SP MCB (10 KA) C Curve CAT - A SI NO. 1002
54
14040
260
S/F of 40 Amp DP isolater CAT - A SI NO. 1005 (A)
4
1820
455
S/F of 40 Amp 4 Pole isolater CAT - A SI NO. 1007 (A)
3
2835
945
Supply and Burrying of 40 mm dia x 4.5 mtr long GI Pipe vertically for earthing having 12 mm Dia holes space 75 mm apart drilled upto 2 mtr from the bottom complete with earthing lead of number 6 to 8 SWG GI wire in GI Pipe Upto Apron (and from apron to switch board the cost of GI wire and Pipe will be extra) Upto switch board, 30 cm square CI box with hinged cover massonary enclosure, Funnel at top, Alternte layers of charcoal/coke and salt atleast 150 mm thick around etc complete in all respect as per direction of E/I. SI No. 701
10
40760
4076
Supply and burrying of safe earthing electrode T-19 (hot dip galvanized) length upto 3000 mm, outer dia 50 mm inner dia 25 mm, terminal dia 12 mm, Outer GI pipe of 16 SWG and inner GI Pipe of 12 SWG with hot dip galvanization upto 100 micron filled with crysatalline conducting mixture having anti corrosive and conductive property with 50 Kgs Activated soil (BFC) Capable of reducing the soil resistivity with good mixture of retaining capacity and one earthing lead of 25 mm x 3 mm GI strip upto switch board (from apron to switch board the coat of GI strip will be extra) along with 30 cm sq CI Frame with hinged and massonary housing as approved in UPPWD and CPRI certified..as per direction of E/I
SI NO. 725 (B)
6
60240
10040
Supply and laying of 25 mm x 3 mm. GI Strip from earth electrode directly in the ground as required complete in all respect .as per direction of E/I SI NO. 716
60
5400
90
Painting of electric pole with two coats of aluminium paint over red oxid primer cmokplete in all respect..as per direction of E/I SI NO. 634
2
648
324
S/F of 3 watt LED path/walkover luminaire Having powder coated die cast alluminium body with driver set. confirming to IP 65 Protection Complete in all respect as per direction of E/I CAT - AAA SI No. 1441
150
271500
1810
Supply and fixing of Factory wire Integral LED Flood Light Luminaires with die cast alluminium housing built with driver set suitable for 100 - 120 watt. Confirming to IP 65 protection Complete in all respect. .as per direction of E/I CAT - AAA SI NO. 1453
10
88500
8850
Supply and fixing decorative 40 to 45 watt LED post Top indirect light lumanaire having pressure die cast alluminium Body and clear glass with driver set confirming to IP 65 protection Complete in all respect. .as per direction of E/I CAT - AAA SI NO. 1443
250
2102500
8410
Supply and fixing of GI pipe 50 mm Dia 20 cm Long for fixing of post Top .as per direction of E/I (@Rs. 70.40/Mtr) SI NO. CH23/23.1
240
3360
14
S/F of 25 mtr High mast shaft of approved make with rising system hot dip galvanized inside and outside dip, having pole sheet thickness 4 mm. top dia minimum 150 mm, bottom dia 460 mm. base plate 32 mm thick suitable or wind velocity as per IS 875 part 3 and having no circumferencial weld, with accesories for high mast such as head frame suitable for 8 to 12 luminaire and its control boxes 1.5 HP power tool motor, 3 point suspension system with steel wire rope 8 mm Dia, Double drum winch, including making suitable foundation as per manufacturer drawing/site requirement along with foundation bolts, nuts, washers, anchor plates etc complete in all respect. .as per direction of E/I SI NO. 654
2
842000
421000
Supply and fixing of Automatic streat light cubical control Panel painted with Anti corrosive alkali and acid proof paint consisting of time switch TSO 100 Series with contractors, HRC fuses, isolating switch metering instrument and instrument box with CT. 25 Amp TPN.as per direction of E/I SI No. 807
1
26500
26500
S/F of factory wire integral LED flood light luminaire with die cast alluminium housing built with driver set suitable for 140-150 watt confirming to IP 66 protection complete in all respect .as per direction of E/I CAT - AAA SI NO. 1454
24
316560
13190
Supply & Making of plinth of ST pole SP -55 of size 45 x 30 cm.above the ground level with 1:2:4 cement concrete Rates including all material, labour, T&P etc. required for proper completion of work as per direciton of E/l SI NO. 282 ch5/2018(PWD)
2
494
247
Supply & Errection of double pole structure for T/F with 11 mt. long S. T. Pole designated SP -55 with 1/6 over all length of pole grouted in 1:3:6 cement, concrete , including Top channel 100 x 50 x 2240 mm., gaurding MS angle 65 x 65 x 6mm. 2.24 mt. long,clamps, Earthing of pole with M.S. rod 11 KV Disc 3 No. 11 KV pin Insulator 3 Nos. including excavation, back filling etc. Rates including all material, labour, T&P etc. required for proper completion of work as per direciton of E/l SI No. UPPCL rates 2018-19
1
52580
52580
S/F of 11 KV TPMO set with required channel, handle switch and insulator etc. complete as per UPCCL norms.& .as per direction of E/I SI No. UPPCL rates 2018-19
1
21504
21504
S/F of 11 K.V. D.O. fuse set on pole complete as per UPCCL norms..as per direction of E/I SI No. UPPCL rates 2018-19
1
8746
8746
S/Insatalation of 11/0.440KV copper wound oil filled air cooled T/F with all accessories breather, temperature meter etc. complete in all respect as per direction E/l & UPPCL approved. (3 star rating) .as per direction of E/I
100 KVA UPPCL rates 2018-19
1
136710
136710
S/F of M.S. angle 75 x 75 x 6 x 2028 mm with clamp ,nut & bolts (T/F base) .as per direction of E/I SI No. UPPCL rates 2018-19
2
4248
2124
S/F of copper "L"piece 50 x 225 x 10 mm. (4 nos. set) .as per direction of E/I SI No. UPPCL rates 2018-19
1
1314
1314
Making suitable earth of S.T. Pole over head line with 2.5 m long 2 mm. dia G.I. Rod 7/16 S.W.G.G.I. earth wire as per present practic of UPPCL including the cost of material, labour t&p etc. required for proper compeletion fo wrok as per direciton of E/l. SI No. UPPCL rates 2018-19
2
1834
917
S/F of L.T. incoming panel with meatering equipment & Fixing arrangment .as per direction of E/I SI No. UPPCL rates 2018-19
1
17490
17490
PART-B
Supply and making Outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including Lugs for 70 Sqmm 3 core, XLP alluminium conductor cable of 11 KV grade. as per direction of E/I SI NO. DSR2018/10.5.1
4
58076
14519
S/F of 100 mm dia B class G.I.pipe (nominal) 3 mt. length along the pole including clamps complete in all respect as per direction of E/l. Si NO. DSR 2018/12.39
4
8572
2143
Supplying and laying of HDPE Pipe .as per direction of E/I
120 mm dia 2893 SI No. DSR2018
360
56160
156
90 mm Dia SI No. 2892
500
48000
96
63 mm Dia SI No. 2891
800
53600
67
Supply and fixing of HDPE Pipe Coupler .as per direction of E/I
120 mm dia 2898 SI NO. DSR2018
60
1800
30
90 mm Dia SI NO. 2897
85
2125
25
63 mm Dia Si No. 2896
140
2240
16
Supplying & Fixing metal box of size 100 x 100 x 60 mm. deep on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as per direction of E/I Si NO. DSR rates 2018/1.22.2
255
40800
160
Supply & Erection of three piece nonlinear resistor type lightning arrestor suitable for 3 wire, 11KV over head lines with rated voltage 9KV (rms) with a nominal discharge current rating of 5 KA and complete with galvanised clamping arrangment, G.I. bolts, nuts, washer etc as required .as per direction of E/I SI NO. DSR rates 2018/13.13
1
2548
2548