Survey, Design, Supply, Installation, Testing And Commissioning Of Towers For Kavach And Other Associated Works Over Central Railway

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply of RCC pipes half round of size 150mm dia outer and 100 mm dia internal 1 mtr long matching to IS No. 458/2003 amendment-1 with Rev.4.(Inspection agency-RITES)

121300

243

29506225

... More
Supply of ARA Terminal blocks with links made of PBT Specn No.IRS/75/2006(Rev-2) with latest amendments and RDSO Drg.No.SA-23741A Alt.4, SA-23745 Alt.5, SA-23746, SA-23748 Alt.4 & SA-23756A Alt.3. (Inspection agency-RDSO)

33306

85

2853658.08

... More
"Excavation of cable trench as per cable route plan,1.0 mt. deep and 300mm wide along side the track in normal soil/strata, conforming to distances as per cable route plan and refilling after cable laying. This work includes covering of cable laid in trench by loose soil for a layer of 50mm thickness after clearing of route,bushes etc. It shall be ensured that top of the cables laid is at a depth of 0.8m or more. It if is less, then the width and depth shall be suitably increased and accordingly proportionate payment shall be made. In case depth of trench is not achievable due to site conditions proportionate payment will be made as per procedure. The work shall be done as per the extant practice on Central Railway and instructions of Railway Engineer at site. Drg. No. SK 805"

31035

413

12817455

... More
"Excavation of cable trench as per cable route plan,1.0 mt. deep and 300mm wide along side the track in hard soil, conforming to distances as per cable route plan and refilling after cable laying. This work 2 includes covering of cable laid in trench by loose soil for a layer of SOmm thickness after clearing of route,bushes etc. It shall be ensured that top of the cables laid is at a depth of 0.8m or more. If it is less, then the width and depth shall be suitably increased and accordingly proportionate payment shall be made. In case depth of trench is not achievable due to site conditions, proportionate payment will be maden as per procedure. The work shall be done as per the extant practice on Central Railway and instructions of Railway Engineer at site. Drg No SK 805"

6996

688

4815556.68

... More
Laying of signalling/Power/Telecom cable of various cores/sizes in trenches.

576.5

6132

3535651.44

... More
Cutting of all types of Roads/ platforms (ecxcept concrete type) for trenching and excavation to 4 depth of 300mmx300mm wide approx. and refilling after laying of RCC/GI /DWC pipe & to restore them to original condition. The work shall be done as per extant practice on C.Rly & instructions of Rly engineer at site.Drg. No. SK 807

642.5

3441

2211272.98

... More
Digging of trench 1.0 M deep from rail flange/road level (for LC) and 0.3Mtrs. to 0.6 Mtrs wide and 5 back filling after placing of DWC/RCC/GI pipe.(Placing of DWC/RCC/GI pipe coverd separately. The ballast disturbed be screened and dressed as required by Engineer-in-charge or his representatives and road tarred immediately. Drg. No. SK 806

1391.5

688

957811.2

... More
Laying of DWC/RCC pipes alongwith collars/RCC Half round pipes in trenches at places of track and road crossings, platform cuttings etc.

129280

67

8672102.4

... More
Wherever depth of 0.5M cable trench is not feasible, cable shall be protected as under:-Preparation of cement mixture 1:3:6 with contractor's own materials and spreading cement concrete mixture layer of 100 mm thick over the already laid cables in the excavated trench.

734.5

6288

4619175.01

... More
Fixing of GI pipes for crossing the culverts, bridges etc. and concreting of ends with brick masonry at both ends as per the instruction of Rly engineer at site.

7980

82

658828.8

... More
"Horizontal boring of cable duct of minimum 2.0 Mtr. depth alongwith laying of 120mm HDPE pipe for track crossing with minimum depth reckoned from the bottom of the rail/road crossing with minimum depth 9 reckoned from ground level. The work shall be done as per extant practice & instructions of site Engineer. Prepration of site for Horizondal boring shall be carried out in presence of Railway Representative. HDPE will be supplied by Railways. Note:- Contractor shall provide all material required for boring and adequate nos. of labours for proper laying of cables into the bore. Cable shall be laid cautiously so that it should not get damage due to rough handling & pressure on cable."

12005

3080

36979481.7

... More
Laying of HDPE duct in trench and its protective work as per direction of site engineer.

150.45

7242

1089679.26

... More
"Horizontal boring of cable duct of minimum 2.0 Mtr. depth alongwith laying of 120mm HDPE pipe for other locations with minimum depth reckoned from ground level. The work shall be done as per extant practice 11 & instructions of site Engineer. Prepration of site for Horizondal boring shall be carried out in presence of Railway Representative. HDPE will be supplied by Railways. Note:- Contractor shall provide all material required for boring and adequate nos. of labours for proper laying of cables into the bore. Cable shall be laid cautiously so that it should not get damage due to rough handling & pressure on cable. BORING upto the length of 150mtrs. Preparation of site for Horizontal Boring shall be carried out in presence of Railway Representative."

9550

2158

20610905.5

... More
Blowing/Drawing of OFC cable in HDPE/DWC duct and protective work, as per direction of site engineer. Per

129.6

15389

1994512.9

... More
"Supply and installation of fiber distribution management system (FDMS) of 48 fibers with (SC/UPC- 1 SC/APC) connector ,19"" rack mounted (48 fibers from each side) including supply of all pig tail and patch cord. Types of Connectors should be of SC/UPC and SC/APC to be used.Make R&M/TYCO/3M or similar. (Inspection agency-RITES)"

759

18683

14180647.47

... More
Supply of OFC Joint Closure for 48 Fibres as per RDSO specification no. RDSO/SPN/TC/68/2014 (Rev. 3 or latest).(Inspection agency-Consignee)

50

4478

223916

... More
Chase cutting 500 mm deep in hard rocky area as per Drg No CORE/ S&T/ALD/SK/579/04 per metre

4903

303

1488452.74

... More
Supply of Optical Power Meter SPECIFICATION:- ATM 100 Optical Power Meter or similar model with (1) 270,1000,2000 Hz tone detection (2) Wide measurement range:-Max. 78 dB, High resolution:0.01 dB, 4 Good accracy: 0.2 dB (3) Insertion loss test in dB, (4)Sm or MM applications (5) FP/PC and 2.5 mm universal connector (6) 850/1300/1310/1490/1550nm calibrated wavelengths (7) ATM 100 is for Telecom testing (8) Energy save mode; about 10 minutes no operation will cause the device automatic power off (can be cancelled) (9) Reference value storage (10) Full energy can support above 100 hrs operation. (Inspection agency-RITES)

21

24920

523320

... More
Supply of OTDR, SPECIFICATION:- JDSU/VIAVI make MTS-4000 OTDR Platform with E4126LA module or similar. (1) Display - Touchscrene, TFT color, 7-in, LCD 800 X 480, high visibility for outdoor. (2) Storage and I/O Interfaces - Internal Memory - 32MB(1000 test results), External memory(optional) - Minimum 5 1GB(optional), 2XUSB2.0, 1XRJ45 Ethernet(up to 1 GB/s), WiFi - Standard IEEE 802.11 b/g, Bluetooth - Class 2, up to 10 mtr range, Ethernet - 10/100/1000 MHz full-half duplex. (3) Power Supply - Standard removable Li-Ion batteries, AC/DC adapter - Input 100-250 V, 50-60 Hz, Output 12-15V DC/3.7A with electrical safety. (4) Power level - +10 to -60 dBm, Calibrated wavelength - 850,1310 1550 nm, Connector type - Universal push/pull. (5) Visual Fault Locator - Wavelength - 635 nm , Output power level - <1mW. (Inspection agency-RITES)

9

320281

2882529.18

... More
Transporting and supply and installation of concrete (RCC) route indicators at intervals of 50 6 meters. They should be standard RCC with letters on one side "CR" and the other side "S&T Cables" as per drawing SK 12/10 of RVNL SC. In case of Telecom quad cable joint locations it shall be painted with RED colour. (Inspection agency-RITES)

2748

1250

3435219.84

... More
Supply of 110mm HDPE pipe for laying in Horizontal Boring as per IS:4984.(Inspection agency- RITES)

21585

700

15109500

... More
Splicing and termination of 48 Fiber OFC (2x48 Fibers) and testing. This include excavation of pit and its back filling & all relevent type of materials for splicing

656

20323

13332425.92

... More
Lattice Tower Self Supporting 40 mtrs height for wind speed of less than or equal to 180 Kmph and Antenna area (EPA) of 6.5 Sq.m

-

-

3110453231.2

... More
Safety Certification of Tower work by Third Party as detailed in the tender document including 4 site inspections and all necessary certification and documentation

665

33040

21971600

... More
Extra site visit by Third Party Certification Agency beyond 4 inspections mentioned in item 2a, if required by Railways

155

5310

823050



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.