Balrampur Tender Results

Balrampur Tender Results

Public Health Engineering Department - PHED Tender Result

Civil And Construction...+1Water Storage And Supply
Result Stage: Under Evaluation
Balrampur, Uttar Pradesh
Construction, Testing And Commissioning Of R.c.c. Elevated Service Reservoir Of 40kl Capacities – 01no. Staging 15m / { Steel Structure 12 M Height & 10 Kl (5000l X 2no.)} Of 03 Nos. Pe Tank & Elevated Service Reservoirs Of Rcc Staging And Hdpe Slim Tank Of Capacity 5000 Ltr Of 03 No. 9 Mtr Staging (with Switch Room Of Size 1.8mx1.8mx3m) And 10000ltr Of 05 No. 12 Mtr Staging.including Providing And Fixing Of Ci Double Flange Pipe, Double Flange Specials & Di Double Flange Soft Seated Sluice Valve Including Construction Of Suitable R.c.c. Valve Chamber Providing, Laying, Jointing, Interconnection, Testing And Commissioning Of Rising Main Upvc Class 10 Kg/sqcm 90 Mm Dia 00 M & Hdpe 75 Mm Dia 00 M & 63 Mm Dia 6250m., Distribution Upvc Class 6kg/sqcm 90mm Dia. 891 M., 110 Mm Dia. 688 M., 140 Mm Dia. 351 M. 160 Mm Dia. 00 M.& Distribution Hdpe Class 6kg/sqcm 63 Mm Dia. 13561 M., 75 Mm Dia. 6560 M.with Suitable Joints Gi Pipe, Valve, Specials And All Fittings Including All Allied Civil Works, Supplying & Installation Of Energy Taging N Five Star Bee Rating Isi Marked Required Capacity Single Phase / Three Phase, 50 Hz, 220v,, Deep Well Submersible Pump Stainless Steel Body, Suitable For 4”/6” Tube Well With Contral Panel Starter Suitable For Submersible Pump With Dry Run Protection, Connections, Including Clamps, Bore Cap Etc. As Required As Per Specifications Butexcludingpipe,ss/nylonwireropeandconnection Cable Including Verification Of Tubewell Yield& Electric Connection From Cspdcl, Construction Of Brick Masonry Switch Room, Construction Of Boundary Wall Around The Over Head Tank, Installation Of Electro Chlorinator , Construction Of Chlorinator Room Of Providing Functional Household Tap Connection (f.h.t.c. 565 ) In Individual Households And Government Instiution Etc. Complete With Trial Run Of 03 Months After That O&mof 06 Months Under Piped Water Supply Scheme Under Jal Jeevan Samari (barpara), Samari (khaspara), Samari (kisanpara), Samari (nagesiyapara), Samari (yadavpara), ,semara(harijanpara), Semara(kenwartoli), Semara(tongaripara), Semara(khaspara), Semara(kudanpani), Semara(linepara), Semara(sarnapara), Semara(uraonpara), Block-kusmi District – Balrampur(c.g.)
Contract DateNA
Contract AmountRefer Documents 

Public Health Engineering Department - PHED Tender Result

Civil And Construction...+1Water Storage And Supply
Result Stage: Under Evaluation
Balrampur, Uttar Pradesh
Construction, Testing And Commissioning Of R.c.c. Elevated Service Reservoir Of 10 Kl Capacities – 0no. & Staging 12mtr / { Steel Structure 12 M Height & 10 Kl (5000l X 2no.)} Of 06 Nos. Pe Tank & Elevated Service Reservoirs Of Rcc Staging And Hdpe Slim Tank Of Capacity 00 Ltr Of 00 No. 9 Mtr Staging And 10000 Ltr Of 00 No. 12 Mtr Staging. Including Providing And Fixing Of Ci Double Flange Pipe, Double Flange Specials & Di Double Flange Soft Seated Sluice Valve Including Construction Of Suitable R.c.c. Valve Chamber Providing, Laying, Jointing, Interconnection, Testing And Commissioning Of Rising Main Upvc Class 10 Kg/sqcm 90 Mm Dia 00 M & Hdpe 75 Mm Dia 1876 M & 63 Mm Dia 00 M., Distribution Upvc Class 6kg/sqcm 90mm Dia. 00 M., 110 Mm Dia. 00 M., 140 Mm Dia. 00 M. 160 Mm Dia. 00 M.& Distribution Hdpe Class 6kg/sqcm 63 Mm Dia. 5779 M., 75 Mm Dia. 2460 M.with Suitable Joints Gi Pipe, Valve, Specials And All Fittings Including All Allied Civil Works, Supplying & Installation Of Energy Taging N Five Star Bee Rating Isi Marked Required Capacity Single Phase / Three Phase, 50 Hz, 220v,, Deep Well Submersible Pump Stainless Steel Body, Suitable For 4”/6” Tube Well With Contral Panel Starter Suitable For Submersible Pump With Dry Run Protection, Connections, Including Clamps, Bore Cap Etc. As Required As Per Specifications Butexcludingpipe,ss/nylonwireropeandconnection Cable Including Verification Of Tubewell Yield& Electric Connection From Cspdcl, Construction Of Brick Masonry Switch Room, Construction Of Boundary Wall Around The Over Head Tank, Installation Of Electro Chlorinator , Construction Of Chlorinator Room Of Providing Functional Household Tap Connection (f.h.t.c. 156 ) In Individual Households And Government Instiution Etc. Complete With Trial Run Of 03 Months After That O&m Of 06 Months Under Piped Water Supply Scheme Under Jal Jeevan Mission For Village Village – Village – Amgaon, (khaspara, Linepara, Baratpara,), Khairadih (bichpara), Block- Shankargarh, District – Balrampur(c.g.)
Contract DateNA
Contract AmountRefer Documents 

Public Health Engineering Department - PHED Tender Result

Civil And Construction...+1Water Storage And Supply
Result Stage: Under Evaluation
Balrampur, Uttar Pradesh
Construction, Testing And Commissioning Ofr.c.c. Elevated Service Reservoir Of 50 Kl Capacities – 01no.& Staging 15 Mtr/ { Steel Structure 12 M Height & 10 Kl(5000l X 2no.)} Of Total 05 Nos. Pe Tank& Elevated Service Reservoirs Of Rcc Staging And Hdpe Slim Tankof Capacity5000 Ltr Of 00 No. 9 Mtr Staging(with Switch Room Of Size 1.8mx1.8mx3m) And 10000 Ltr Of 01 No. 12 Mtr Staging.including Providing And Fixing Of Ci Double Flange Pipe, Double Flange Specials & Di Double Flange Soft Seated Sluice Valve Including Construction Of Suitable R.c.c. Valve Chamber. Providing, Laying, Jointing, Interconnection, Testing And Commissioning Of Rising Main Upvc Class 10 Kg/sqcm 90 Mm Dia 00 M & Hdpe 75mm Dia 1577 M & 63 Mm Dia 2152 M.,distribution Upvc Class 6kg/sqcm 90mm Dia. 405 M., 110 Mm Dia. 320 M., 140 Mm Dia. 211 M. 160 Mm Dia. 00 M.& Distribution Hdpe Class 6kg/sqcm 63 Mm Dia. 7043 M., 75 Mm Dia. 2891 M.with Suitable Joints Gi Pipe, Valve, Specials And All Fittings Including All Allied Civil Works, Supplying & Installation Of Energy Taging N Five Star Bee Rating Isi Marked Required Capacity Single Phase / Three Phase, 50 Hz, 220v,, Deep Well Submersible Pump Stainless Steel Body, Suitable For 4”/6” Tube Well With Contral Panel Starter Suitable For Submersible Pump With Dry Run Protection, Connections, Including Clamps, Bore Cap Etc. As Required As Per Specifications Butexcludingpipe,ss/nylonwireropeandconnection Cable Including Verification Of Tubewell Yield& Electric Connection From Cspdcl, Construction Of Brick Masonry Switch Room, Construction Of Boundary Wall Around The Over Head Tank, Installation Of Electro Chlorinator , Construction Of Chlorinator Room Of Providing Functional Household Tap Connection (f.h.t.c. 394 ) In Individual Households And Government Instiution Etc. Complete With Trial Run Of 03 Months After That O&mof 06 Months Under Piped Water Supply Scheme Under Jal Jeevan Mission For Village – Khajuri (khaspara, Schoolpara, Uraonpara), Khajuri (lechopara), Khajuri (miyapara), Khajuri (turripani) Block- Kusmi, District – Balrampur(c.g.)
Contract DateNA
Contract AmountRefer Documents 

Public Health Engineering Department - PHED Tender Result

Civil And Construction...+1Water Storage And Supply
Result Stage: Under Evaluation
Balrampur, Uttar Pradesh
Construction, Testing And Commissioning Ofr.c.c. Elevated Service Reservoir Of 00 Kl Capacities – 00no.& Staging 12 Mtr/ { Steel Structure 12 M Height & 10 Kl (5000l X 2no.)} Of 00 Nos. Pe Tank & Elevated Service Reservoirs Of Rcc Staging And Hdpe Slim Tankof Capacity 05kl Of 00 No. 9 Mtr Staging And 10kl Of 00 No. 12 Mtr Staging. Including Providing And Fixing Of Ci Double Flange Pipe, Double Flange Specials & Di Double Flange Soft Seated Sluice Valve Including Construction Of Suitable R.c.c. Valve Chamber Providing, Laying, Jointing, Interconnection, Testing And Commissioning Of Rising Main Upvc Class 10 Kg/sqcm 90 Mm Dia 00 M & Hdpe 75 Mm Dia 00 M & 63 Mm Dia 00 M.,distribution Upvc Class 6kg/sqcm 90mm Dia. 00 M., 110 Mm Dia. 00 M., 140 Mm Dia. 00 M. 160 Mm Dia. 00 M.& Distribution Hdpe Class 6kg/sqcm 63 Mm Dia. 8046 M., 75 Mm Dia. 735 M.with Suitable Joints Gi Pipe, Valve, Specials And All Fittings Including All Allied Civil Works, Supplying & Installation Of Energy Taging N Five Star Bee Rating Isi Marked Required Capacity Single Phase / Three Phase, 50 Hz, 220v,, Deep Well Submersible Pump Stainless Steel Body, Suitable For 4”/6” Tube Well With Contral Panel Starter Suitable For Submersible Pump With Dry Run Protection, Connections, Including Clamps, Bore Cap Etc. As Required As Per Specifications Butexcludingpipe,ss/nylonwireropeandconnection Cable Including Verification Of Tubewell Yield& Electric Connection From Cspdcl, Construction Of Brick Masonry Switch Room, Construction Of Boundary Wall Around The Over Head Tank, Installation Of Electro Chlorinator , Construction Of Chlorinator Room Of Providing Functional Household Tap Connection (f.h.t.c. 269 ) In Individual Households And Government Instiution Etc. Complete With Trial Run Of 03 Months After That O&mof 06 Months Under Piped Water Supply Scheme Under Jal Jeevan Mission For Village–subhashnagar (bandhpara), Subhashnagar (societypara), Subhashnagar (bichpara), Subhashnagar (g.s.i Colony), Subhashnagar (khaspara), Subhashnagar (nirmaltola), Subhashnagar (paschimpara), Subhashnagar (schoolpara), Subhashnagar (gidhaniya), Block- Ramchandrapur, District – Balrampur(c.g.)
Contract DateNA
Contract AmountRefer Documents 

Public Health Engineering Department - PHED Tender Result

Civil And Construction...+1Water Storage And Supply
Result Stage: Under Evaluation
Balrampur, Uttar Pradesh
Construction, Testing And Commissioning Of R.c.c. Elevated Service Reservoir Of 00 Kl Capacities – 00 No. & Staging 12 Mtr / { Steel Structure 12 M Height & 10 Kl (5000l X 2no.)} Of 03 Nos. Pe Tank & Elevated Service Reservoirs Of Rcc Staging And Hdpe Slim Tank Of Capacity 00 Ltr Of 00 No. 9 Mtr Staging And 00 Ltr Of 00 No. 12 Mtr Staging. Including Providing And Fixing Of Ci Double Flange Pipe, Double Flange Specials & Di Double Flange Soft Seated Sluice Valve Including Construction Of Suitable R.c.c. Valve Chamber Providing, Laying, Jointing, Interconnection, Testing And Commissioning Of Rising Main Upvc Class 10 Kg/sqcm 90 Mm Dia 00 M & Hdpe 75 Mm Dia 1945 M & 63 Mm Dia 00 M., Distribution Upvc Class 6kg/sqcm 90mm Dia. 00 M., 110 Mm Dia. 00 M., 140 Mm Dia. 00 M. 160 Mm Dia. 00 M.& Distribution Hdpe Class 6kg/sqcm 63 Mm Dia. 12559 M., 75 Mm Dia. 1180 M.with Suitable Joints Gi Pipe, Valve, Specials And All Fittings Including All Allied Civil Works, Supplying & Installation Of Energy Taging N Five Star Bee Rating Isi Marked Required Capacity Single Phase / Three Phase, 50 Hz, 220v,, Deep Well Submersible Pump Stainless Steel Body, Suitable For 4”/6” Tube Well With Contral Panel Starter Suitable For Submersible Pump With Dry Run Protection, Connections, Including Clamps, Bore Cap Etc. As Required As Per Specifications Butexcludingpipe,ss/nylonwireropeandconnection Cable Including Verification Of Tubewell Yield& Electric Connection From Cspdcl, Construction Of Brick Masonry Switch Room, Construction Of Boundary Wall Around The Over Head Tank, Installation Of Electro Chlorinator , Construction Of Chlorinator Room Of Providing Functional Household Tap Connection (f.h.t.c. 223 ) In Individual Households And Government Instiution Etc. Complete With Trial Run Of 03 Months After That O&m Of 06 Months Under Piped Water Supply Scheme Under Jal Jeevan Mission For Village – Indrawatipur (ghasiyapara), Indrawatipur (gondpara), Indrawatipur (schooltola), Indrawatipur (yadavpara), Block- Ramchandrapur, District – Balrampur(c.g.)
Contract DateNA
Contract AmountRefer Documents 

Public Health Engineering Department - PHED Tender Result

Civil And Construction...+1Water Storage And Supply
Result Stage: Under Evaluation
Balrampur, Uttar Pradesh
Construction, Testing And Commissioning Of R.c.c. Elevated Service Reservoir Of 00 Kl Capacities – 00 No. & Staging 15 Mtr / { Steel Structure 12 M Height & 10 Kl (5000l X 2no.)} Of 10 Nos. Pe Tank & Elevated Service Reservoirs Of Rcc Staging And Hdpe Slim Tank Of Capacity 5000 Ltr Of 00 No. 9 Mtr Staging (with Switch Room Of Size 1.8mx1.8mx3m) And 10000 Ltr Of 00 No. 12 Mtr Staging. Including Providing And Fixing Of Ci Double Flange Pipe, Double Flange Specials & Di Double Flange Soft Seated Sluice Valve Including Construction Of Suitable R.c.c. Valve Chamber. Providing, Laying, Jointing, Interconnection, Testing And Commissioning Of Rising Main Upvc Class 10 Kg/sqcm 90 Mm Dia 00 M & Hdpe 75mm Dia 00 M & 63 Mm Dia 6103 M., Distribution Upvc Class 6kg/sqcm 90mm Dia. 00 M., 110 Mm Dia. 00 M., 140 Mm Dia. 00 M. 160 Mm Dia. 00 M.& Distribution Hdpe Class 6kg/sqcm 63 Mm Dia. 15001 M., 75 Mm Dia. 5242 M.with Suitable Joints Gi Pipe, Valve, Specials And All Fittings Including All Allied Civil Works, Supplying & Installation Of Energy Taging N Five Star Bee Rating Isi Marked Required Capacity Single Phase / Three Phase, 50 Hz, 220v,, Deep Well Submersible Pump Stainless Steel Body, Suitable For 4”/6” Tube Well With Contral Panel Starter Suitable For Submersible Pump With Dry Run Protection, Connections, Including Clamps, Bore Cap Etc. As Required As Per Specifications Butexcludingpipe,ss/nylonwireropeandconnection Cable Including Verification Of Tubewell Yield& Electric Connection From Cspdcl, Construction Of Brick Masonry Switch Room, Construction Of Boundary Wall Around The Over Head Tank, Installation Of Electro Chlorinator , Construction Of Chlorinator Room Of Providing Functional Household Tap Connection (f.h.t.c. 400 ) In Individual Households And Government Instiution Etc. Complete With Trial Run Of 03 Months After That O&m Of 06 Months Under Piped Water Supply Scheme Under Jal Jeevan Mission For Village – Dolangi (ahirpara, Bandhpara, Bazarpara, Khaspara, Masjidpara), Dolangi (uttartola, Tikarapara, Paschimpara, Patelpara, Postpara), Block- Ramchandrapur, District – Balrampur(c.g.)
Contract DateNA
Contract AmountRefer Documents 

Public Health Engineering Department - PHED Tender Result

Civil And Construction...+1Water Storage And Supply
Result Stage: Under Evaluation
Balrampur, Uttar Pradesh
Construction, Testing And Commissioning Ofr.c.c. Elevated Service Reservoir Of 40 Kl Capacities – 01 No.& Staging 15mtr/ { Steel Structure 12 M Height & 10 Kl (5000l X 2no.)} Of 00 Nos. Pe Tank& Elevated Service Reservoirs Of Rcc Staging And Hdpe Slim Tank Of Capacity 00ltr Of 00 No. 9 Mtr Staging(with Switch Room Of Size 1.8mx1.8mx3m) And 10000ltr Of 11 No. 12 Mtr Staging. Including Providing And Fixing Of Ci Double Flange Pipe, Double Flange Specials & Di Double Flange Soft Seated Sluice Valve Including Construction Of Suitable R.c.c. Valve Chamber. Providing, Laying, Jointing, Interconnection, Testing And Commissioning Of Rising Main Upvc Class 10 Kg/sqcm 90 Mm Dia00 M & Hdpe 75 Mm Dia00 M & 63 Mm Dia5619 M.,distribution Upvc Class 6kg/sqcm 90mm Dia. 824 M., 110 Mm Dia. 84 M., 140 Mm Dia. 25 M. 160 Mm Dia. 00 M.& Distribution Hdpe Class 6kg/sqcm 63 Mm Dia. 8371 M., 75 Mm Dia. 5178m.with Suitable Joints Gi Pipe, Valve, Specials And All Fittings Including All Allied Civil Works, Supplying & Installation Of Energy Taging N Five Star Bee Rating Isi Marked Required Capacity Single Phase / Three Phase, 50 Hz, 220v,, Deep Well Submersible Pump Stainless Steel Body, Suitable For 4”/6” Tube Well With Contral Panel Starter Suitable For Submersible Pump With Dry Run Protection, Connections, Including Clamps, Bore Cap Etc. As Required As Per Specifications Butexcludingpipe,ss/nylonwireropeandconnection Cable Including Verification Of Tubewell Yield& Electric Connection From Cspdcl, Construction Of Brick Masonry Switch Room, Construction Of Boundary Wall Around The Over Head Tank, Installation Of Electro Chlorinator , Construction Of Chlorinator Room Of Providing Functional Household Tap Connection (f.h.t.c. 362 ) In Individual Households And Government Instiution Etc. Complete With Trial Run Of 03 Months After That O&mof 06 Months Under Piped Water Supply Scheme Under Jal Jeevan Mission For Village – Pipraul (khairwarpara), Pipraul (pahadtola), Pipraul (panikapara), Pipraul (panditpara), Pipraul (purvtola), Pipraul (gondpara), Pipraul (loharpara), Block- Ramchandrapur, District – Balrampur(c.g.)
Contract DateNA
Contract AmountRefer Documents 

Public Health Engineering Department - PHED Tender Result

Civil And Construction
Result Stage: Under Evaluation
Balrampur, Uttar Pradesh
Construction, Testing And Commissioning Of R.c.c. Elevated Service Reservoir Of 00 Kl Capacities – 00 No. & Staging 12 Mtr / { Steel Structure 12 M Height & 10 Kl (5000l X 2no.)} Of 02 Nos. Pe Tank & Elevated Service Reservoirs Of Rcc Staging And Hdpe Slim Tank Of Capacity 5000 Ltr Of 01 No. 9 Mtr Staging (with Switch Room Of Size 1.8mx1.8mx3m) And 00 Ltr Of 00 No. 12 Mtr Staging. Including Providing And Fixing Of Ci Double Flange Pipe, Double Flange Specials & Di Double Flange Soft Seated Sluice Valve Including Construction Of Suitable R.c.c. Valve Chamber Providing, Laying, Jointing, Interconnection, Testing And Commissioning Of Rising Main Upvc Class 10 Kg/sqcm 90 Mm Dia 00 M & Hdpe 75 Mm Dia 00 M & 63 Mm Dia 740 M., Distribution Upvc Class 6kg/sqcm 90mm Dia. 00 M., 110 Mm Dia. 00 M., 140 Mm Dia. 00 M. 160 Mm Dia. 00 M.& Distribution Hdpe Class 6kg/sqcm 63 Mm Dia. 3964 M., 75 Mm Dia. 1018 M.with Suitable Joints Gi Pipe, Valve, Specials And All Fittings Including All Allied Civil Works, Supplying & Installation Of Energy Taging N Five Star Bee Rating Isi Marked Required Capacity Single Phase / Three Phase, 50 Hz, 220v,, Deep Well Submersible Pump Stainless Steel Body, Suitable For 4”/6” Tube Well With Contral Panel Starter Suitable For Submersible Pump With Dry Run Protection, Connections, Including Clamps, Bore Cap Etc. As Required As Per Specifications Butexcludingpipe,ss/nylonwireropeandconnection Cable Including Verification Of Tubewell Yield& Electric Connection From Cspdcl, Construction Of Brick Masonry Switch Room, Construction Of Boundary Wall Around The Over Head Tank, Installation Of Electro Chlorinator , Construction Of Chlorinator Room Of Providing Functional Household Tap Connection (f.h.t.c. 109 ) In Individual Households And Government Instiution Etc. Complete With Trial Run Of 03 Months After That O&m Of 06 Months Under Piped Water Supply Scheme Under Jal Jeevan Mission For Village – Tendua (bhandarpara, Khaspara), Tendua (koilaritola, Pandopara), Tendua (yadavpara), Block- Ramchandrapur, District – Balrampur(c.g.)
Contract DateNA
Contract AmountRefer Documents 

Rural Engineering Service - RES Tender Result

Paints and Enamels
Result Stage: Under Evaluation
Balrampur, Uttar Pradesh
Zonal Tender For Electrification Work Under Janpan Panchayat Area Of Rajpur
Contract DateNA
Contract AmountRefer Documents 

Chhattisgarh State Cooperative Dairy Federation Limited Tender Result

Result Stage: Under Evaluation
Balrampur, Uttar Pradesh
Paddy Husk (bhusa) For Kms -2021-22
Contract DateNA
Contract AmountNA 
7621-7630 of 7979 active Tender Results