Tamil Nadu Generation And Distribution Corporation Limited - TANGEDCO Tender Result

Works
Electrical and Electronics
Electrical Works
Contract DateNA
Contract Period90 Days
Contract AmountRefer Documents 
Download

Result Stages

  • Technical Bid Opening Date

    25 Apr 2025 05:35 PM
  • Technical Evaluation Date

    16 May 2025 01:55 PM

AOC Description

-Name of work 1)Imp estimate for shifting of 1no 8mtr RCC pole as per the request of The Public, Mekkottukonam under Puthenchanthai Section. 2)Improvement estimate for shifting of 1no 8mtr PSC Pole as per the request of Thiru.Maniyan, Kizhakkethottam, under Puthenchanthai section. 3)Estimate for replacement of HT/LT line 1 no 8m PSC into 9m PSC pole for line clearance at location F1/10 in Exchange SS/100KVA under Puthenchanthai section. 4)Estimate for replacement ot H I /LT line 1no 8m PSC pole for line clearance at location FI/1 in MPM Market SS1/63KVA under Puthenchanthai section. 5)Elecy. replacement of HT/LT line 2nos changing 8mtr pole into 9mPSC pole for ground clearance under Puthenchanthai Section. 6)Estimate for improving the low voltage at Panankalaivilai area of Vavaraivilai SS 63KVA by transfer the load to Kurumadathukulam SS 63KVA under Puthenchanthai section. 7)Estimate for replacement of aged conductor deteriorated pole and strengthening of conductor in LT line ACSR 7/2.59 and 7/2.11 change to AAAC 7/3.15 as per request of Thiru.S.G.Sajayakumar at Parayadivilai under Puthenchanthai Section. 8)Replacement of 1no deteriorated 9mtr PSC pole at loc FI/9 in Kuzhijanvilai SS 100 KVA under Puthenchanthai Section. 9)Replacement of 1no deteriorated 9.14mtr RCC pole at loc FII/2 in Malamari SS I 100 KVA under Puthenchanthai Section. 10)Insertion of 1no 8mtr PSC pole at loc FI/3-4 in Mulluvilai SS 100KVA under Puthenchanthai section. 11)Insertion of 1no 8mtr PSC pole at loc FI/16-17 in Mullacheri SS I 250 KVA under Puthenchanthai section. 12)Replacement of 1no deteriorated 9.14mtr RCC pole at loc FI/1 in Rakulam SS 100 KVA under Puthenchanthai Section. 13)Replacement of 3nos deteriorated 8 mtr PSC pole at various location no Fl/34, Fl/40 and F2/18 in VHSS 250KVA under Puthenchanthai section. 14)Replacement of 1nos deteriorated 8 mtr PSC pole at various location no Fl/4 in KannapuramSS II 100 KVA under Puthenchanthai section. 15)Insertion of 1no 8mtr PSC pole at loc FI/9-10 in Kuzhijanvilai SS I 100 KVA under Puthenchanthai distribution section. 16)Replacement of 1nos deteriorated 8 mtr RCC pole at location no Fl/14 in Elluvilai SS 100 KVA under Puthenchanthai section. 17)Replacement of 1nos deteriorated 8 mtr PSC pole at location no Fl/93 in Perumpila SS 63 KVA under Puthenchanthai section. 18)Insertion of 1no 8mtr PSC pole at loc FII/19 to 20 in VH SS 250 KVA under Puthenchanthai section. 19)Replacement of 2 nos deteriorated 8 mtr RCC pole at location no FlI/36&54 in Puthuvettukonam SS II 100 KVA under Puthenchanthai section. 20)Replacement of 1nos deteriorated 8 mtr PSC pole at location no Fl/15 in PTC SS II 63 KVA under Puthenchanthai section. 21)Natural Calamity estimate for replacement of 1no 8mtr PSC pole at loc no:FI/17 of Kudukkachivilai SS 100 KVA damaged due to fallen of rubber tree over LT line under Puthanchanthai Section. 22)Natural Calamity estimate for replacement of 1no 8mtr PSC pole at loc no:FII/31 of VH SS 250 KVA damaged due to fallen of rubber tree over LT line under Puthanchanthai Section. 23)Natural Calamity estimate for replacement of 1no 8mtr PSC pole at loc no:FI/7 of Ambatinkalai SS 63 KVA damaged due to fallen of Ayani tree over LT line under Puthanchanthai Section. 24)Natural Calamity estimate for replacement of 1no 8mtr PSC pole at loc no:FII/9 of Puthenchanthai SS 100 KVA damaged due to fallen of coconut tree over LT line under Puthanchanthai Section. 25)Natural Calamity estimate for replacement of 2 nos 8mtr PSC pole at loc no:FII/13,18 of Pilavilai SS 100 KVA damaged due to fallen of rubber tree over LT line under Puthanchanthai Section. 26)Natural Calamity estimate for replacement of 1 nos 8mtr PSC pole at loc no:FII/28 of Kanjiyodu SS 63 KVA damaged due to fallen of rubber tree over LT line under Puthanchanthai Section. 27)Natural Calamity estimate for replacement of 1 nos 8mtr PSC pole at loc no:FI/9 of VH SS 250 KVA damaged due to fallen of tree over LT line under Puthanchanthai Section. 28)Natural Calamity estimate for replacement of 1 nos 8mtr PSC pole at loc no:FI/7 of Pakode SS II 63 KVA damaged due to fallen of tree over LT line under Puthanchanthai Section. 29)Natural Calamity estimate for replacement of 1 nos 9.14mtr RCC pole at loc no:FII/3 of Kallupalam SS 63 KVA damaged due to fallen of tree over HT/LT line under Puthanchanthai Section. 30)Maintenance estimate for the 11 KV line Tree clearance work from Malapuram ABS to Malamari ABS of 11 KV Mukkuttukadal feeder under Puthenchanthai Section in Kanyakumari Electricity Distribution Circle.

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

Bidder Details

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Bidder AddressThis Information is for unsubscribed user
  • Award Amount234234234200
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Bidder AddressThis Information is for unsubscribed user
  • Award Amount234234234200
  • Qualified BiddersThis is message for unregistered
  • Lowest Bidder662
  • Number of Bids99
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.