RITES Limited Tender

... More
For getting the details of etenders, if you are looking for information about them from the cumbersome government websites but are tired of doing so, Bidassist comes up with a one stop solution. It collates every Eproc telangana tender on Bidassist. One can approach it for the bidding process, registration process, etc., are explained below.

RITES Limited - RITES Tender

Works
Civil And Construction
Electrical and Electronics
Electrical Works
Eprocure
Opening Date16 Apr 2025
Closing Date13 May 2025
Tender Amount₹ 22,69,72,789 
Notes
Download

AI Insights

Class Of Bidder
... View More
Class-I Local Suppliers are eligible to bid or participate in this tender.
Technical Capacity
... View More
The required prior work experience for the bidder includes satisfactorily completing or substantially completing at least one similar work of minimum value or at least two similar works each of minimum value during the last 7 years prior to the last stipulated date for submission of the Bid. For works completed abroad, the value should be converted into Indian Rupees, and the bidder should have also completed at least one similar work of value minimum 25% of estimated cost of work in India in the last seven years. In joint ventures, each partner should have satisfactorily completed at least one similar work of minimum value of 10% of the Estimated cost of work during the last 7 years. The value of similar work is calculated excluding the element of GST on works Contract Service, with a weightage of 7% given for equating the value of works to the last stipulated date for submission of the Bids. Additionally, specific designations have minimum working experience requirements: Principal Technical Representative (10 Years), Deputy Technical Representative (5 Years), and Engineers (0-5 Years). However, specific details on the required amount and percentage of similar works completed are not provided, except for the 25% and 10% values mentioned for works in India and joint ventures, respectively.

Costs

Summary

TGGENCO - (5x800MW)YTPS - S&T Stage-II for Railway siding of YTPS - Supply, Installation, Testing & Commissioning of New Electronic Interlocking System

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Testing of 24 fibers loss section wise

2

11289

22578.34

... More
SCHEDULE - F TELECOM EXECUTION

-

-

-

... More
`B' type choke as per specification No.IRS-S-65/ 83 Amndt -3

10

2701

27017.9

... More
(17) Poker 8" (for removing bond wire, bond pin )- 1 No.

-

-

-

... More
VF Tapping Transformers as per the RDSO Spec. IRS TC 22-76 or latest RDSO specification, 470:600 for 6 Quad cable at Data logger and BPAC and C gate communication.

4

1167

4668.36

... More
Half Location box

12

918

11019.72

... More
Supply of GKP type Location Boxes Full size as per drg. No. S&T/ MFT/ 2378 (Single).

65

14005

910384.15

... More
Painting of two coats of enamel paint black Asian and Aluminium white as approved by Site engineer over one coat of primer on Shunt signal unit, base and post. Work has to be done as SC Railway Practice.

57

825

47032.98

... More
(8) Wire stripper (Taparia ) - 1 No.

-

-

-

... More
Erection of 2/ 3/ 4 aspect colour light signals. This includes :

24

4575

109822.08

... More
Ward combination key & flap of crank handle group. 1 set includes minimum 1 no key & 2 no. of point machine cover flap or as per approved SIP

61

1009

61554.49

... More
All the supplies (both hardware & software) required for installing the electronic interlocking and making it functional is part of the schedule.

-

-

-

... More
Supply of 4 wire DTMF Control Telephone spec.IRS-TC-38/ 97 with Amendment-1 or latest

1

3970

3970.62

... More
Laying of track transducers cable from rail to way side electronic unit.

-

-

-

... More
24 fiber armoured optic fiber cable mono mode as per RDSO specn. Nos. IRS: TC-55/ 2006 Rev.-1, with latest amendment.

15

97366

1460495.7

... More
(18) Screw Driver Heavy duty 12" with plastic handle (for opening of detector contacts (Taparia) - 1No.

-

-

-

... More
On Point & Crossing

2

5796

11593.74

... More
(24) sealing Plier - 1 No.

-

-

-

... More
c) Copper strip of 150X25x6mm to terminate earth rod-1 No.

-

-

-

... More
Blowing of OFC in HDPE duct & DWC pipe through OFC blowing machine. Where it is not feasible to blow OFC due to curves, road/ track crossings, bridges or for any other reason, OFC shall be drawn/ laid manually as per standard procedure. All the equipments and machinery required shall be arranged by the contractor at his own cost. In case OFC is to be laid adopting Direct in trench method then this item shall be paid as per accepted rate of laying HDPE duct.

15

12202

183037.2

... More
60 C x 1 mm dia.

1

311341

311341.66

... More
Schedule B EXECUTION

-

-

-

... More
Supply and design of complete system of Multi Section type Digital Axle Counter (MSDAC) as per RDSO's specification No. RDSO/ SPN/ 176/ 2013 ver 3 or latest, firm's specn. and Technical specification para 4.0. to suit SIP. This item also includes supply of: 1. Supply of final track clearance relay for each track section, 2. Detection point (double rail contact) and track side electronics along with housing with all accessories and fixing arrangement like deflector plate, protecting tube etc. as required for the system. 3. Reset Boxes, 4. Portable operator console for onsite programming of axle counter system if any. 5. DC-DC converters (110V input and output voltage as required for system)

125

409522

51190318.75

... More
Supply of QNA1K Relays 6F/ 6B (24 V, 1000 Ohms) for WJR contacts metal to carbon with plug board, retaining clip & connectors conforming to BRS:931A, 933A, 932A, 935A 937A 960 & RDSO/ SPN/ 84 ver 2.0

10

5767

57675.3

... More
(29) Track shorting clips - 1 No.

-

-

-

... More
e) Copper strip of 150X25x6mm (SEEB)-1 No

-

-

-

... More
(5) Cutting plier 6" (Taparia ) - 1 No.

-

-

-

... More
Fixing of angle iron frame for "Q" type relays in location box. This includes supply of angle iron for fixing relays wherever required.

-

-

-

... More
Supply of maintainer's tool kit consisting of items as per list below :-

2

74733

149467.2

... More
04 nos. anchor bolts for shunt signal (305mm X 50mm X 20mm) to drg.No.SA-110 A/ M.

-

-

-

... More
E.I.'s Internal Data logger should confirm to clause 5.15 of RDSO/ SPN/ 192/ 2005. Connectivity to be EI from EI Internal Data logger to the external data logger to view the logged information.

-

-

-

... More
Supply of cable route tracer with specification similar to RD 7100

1

317033

317033.16

... More
Wiring & testing of main signal and subsidiary signals (where provided).

-

-

-

... More
Relay 'Q' series neutral line, AC Immune, plug-in type, Style `QNA1'. DC Neutral line, 24V, 12F/ 4B contacts, front and back contacts metal to carbon with plug board, retaining clip & connectors conforming to BRS:931A, IRS:S 60, IRS:S 34 & IRS:S 23 with latest amendment (as applicable).

31

4956

153640.96

... More
04 nos. Anchor bolts complete (915 mm x 75mm x 24 mm) to drg.No.SA-116 A/ M & IRS-S-10/ 78

-

-

-

... More
Supply of Double wall corrugated (DWC) pipe in 2/ 3 meter length produced out of full round DWC pipes as per IS:14930 part-II marked on it. This item includes supply of necessary fixing & coupling arrangement. Size 200mm outer dia and 175 mm inner dia

7000

450

3150420

... More
(19) Test piece (Pt wedge piece) - 2 No.

-

-

-

... More
(14) Hacksaw frame with blade 6", 4" width (for cutting cable) - 1 No.

-

-

-

... More
Supply of 24F Rack Mount FCPC FMS loaded with 24 nos each of FCPC couplers and pigtail (2 x 24 Fiber), as per RDSO/ SPN/ TC/ 37/ 2000 Rev.3 Amendment-1 or latest

1

17813

17813.74

... More
Note: Due to local condition in very special circumstances if the size of the foundation for all the above items, required to be increased/ decreased, the extra payment deduction for variation of the CC work shall be calculated on volumetric basis as per rate of item no. 24.

-

-

-

... More
Office Table of size of table top 1220 mm x 610mm height 750mm with laminated top with 3 drawers on the left hand side and one locker on the right hand side olive brown with Duplicate keys. Olive green colour Godrej/ zuari Make.

3

18585

55755.6

... More
Washers - 4 No.

-

-

-

... More
Signal post 140 mm dia 4.5 mtrs. long to IRS-S-6-81.

-

-

-

... More
Colour Light Signal Unit 2 Aspect complete without signal transformers, lenses & lamps, suitable for 140 mm dia.post as per drg.No.SA - 23003 A/ M (Adv.) alt.9 & Specn. IRS-S-26/ 64.

-

-

-

... More
Installation, wiring, testing and commissioning of Integrated Power Supply (IPS) system as per instructions given in Installation manual of OEM and technical specification. This includes supply of all materials required for installation and initial charging of VRLA batteries (3 cycles).

2

51485

102971.94

... More
(3)Multi meter (Digital PHILIPS/ FLUKE/ 18S Rishi B) Upto 20M.ohms 10A, 5KHZ, 2mV to 750V AC, 200V DC - 1 No. TRUE RMS METER

-

-

-

... More
Supply of 2 x 24 fiber optic fiber splice straight joint enclosure (SJC) complete with all accessories As per RDSO specn. Nos. RDSO/ SPN/ TC/ 68/ 2014 REV.1.0

10

3828

38283.1

... More
Supply of End plate for above item no. 40 wago make or similar. (orange)

200

8

1712

... More
Supply of SMPS based 48V/ 50 amps battery charger for telecom use as per spec. no. RDSO/ SPCN/ TL/ 23/ 99 (ver.4) or latest in N+1 configuration i.e. using 3 modules of 25 amps with automatic switching between the modules for two sets of 200 AH battery. It shall be equipped with surge and lightening protection of class `B' and `C' the configuration shall be decided as per site requirement. This item also include connectors, wires etc for regrouping of VRLA battery sets.

1

112177

112177.37

... More
Supply of 20 pair krone type DP box with locking arrangement

6

4818

28911.54

... More
(i) Supply of 4 nos. anchor bolts as per RDSO drawing no. SA-112A with nuts and washers.

-

-

-

... More
Channel side plate LH -2 No.

-

-

-

... More
Insulating plate - 2 No.

-

-

-

... More
Insulation for following & leading P-way stretcher bar for BG as per IRS-S-40/ 84 & drg.no.10367 10368 & 10371 each set comprising of :

120

467

56040

... More
(32) Supply of Earth Tester digital Waco/ Motwani/ Rishab.

-

-

-

... More
Supply of 6 pin Emergency Plug socket, flat type as per RDSO DRG no. TCA-15225t. (Similar to Epsilon make). IRS TC 42-87 with Amendment-1 or latest.

6

654

3926.94

... More
Bunching of cables with PVC tape including supply of ferrules, tape, cable fixing clamps etc.

-

-

-

... More
Fixing & laying of GI pipe (Supply of GI Pipe is covered separately) at crossing or culverts along bridges etc. and concreting the ends with brick channelling at both ends as per Drg. No. SK/ SC/ CN/ west12/ 87. This includes fixing of clamps of suitable size & shape where more than one pipe length is required to be kept at stretch. The clamps will mild steel strip of 5mm thick & 25mm wide approx. A minimum of 3 clamps per GI pipe of standard length of 6 mtrs. to be provided.

700

369

258762

... More
Supply of rubber mat 2000mm x 500mm x 12mm

20

1172

23444.6

... More
Filling up pit inside the location box by sand and plastering on the top of the sand.

-

-

-

... More
Supply of PSU (Wall mounted 12V, 7AH fully charged, maintenance free valve regulated sealed lead acid stationery battery along with B + charger as per RDSO spec. No. 72/ 97 (Amd-1) or latest for driving 4W DTMF way station cto equipment complete along with copy of maintenance manual.

2

6644

13288.8

... More
Supply of EKT/ RKT as per spec no IRS S-21/ 2001 & Drg No SA22601(Allt 4)

1

6734

6734.5

... More
Fixing of hoods & LED lamp units with current regulator on 2/ 3/ 4 aspect signal unit & and subsidiary signals (where provided). Termination of the tail cable in the signal unit.

-

-

-

... More
(15) Hammer 3.0 lbs 1 No.

-

-

-

... More
Axle Counter plan

-

-

-

... More
Signal base Cast Iron 140 mm dia. to drg. No. S-2011/ M.

-

-

-

... More
Laying of 40/ 33 mm dia HDPE as per approved cable route plan

15

6571

98575.05

... More
Supply & Erection of NI control panel - for way station with suitable foundation. The cables behind the panel shall be covered with mix of earth soil and sand. The top portion (floor) shall be plastered. If the tiles are removed for placing control panel, the tiles shall be re-fixed.

2

112677

225354.5

... More
Transporting, Supply and installation of Concrete (RCC) route indicators at intervals of 50 meters as per technical specification. They should be of standard RCC with letters "SCR S&T cable" as per type of cable laid to drawing OF SCR. In case of telecom quad cable joint locations it shall be painted with red color. All material required for casting & curing foundations, fixing equipment, smithy works, making rod/ wire run nut bolts.etc. shall be supplied by the contractor.

350

583

204309

... More
Installation, wiring, testing & commissioning of track circuit involving points & crossings as per track circuiting plan. The work includes testing of track battery after charging and installation. This work is including drilling 9/ 32" hole on rails; fixing of bonding(double) with 8 swg soft GI wire & jumper rope wire, fixing of track lead junction box, rail connector with GI wire, track jumpering as per site Engineer.

-

-

-

... More
Cutting of masonry walls and refilling after laying of cable at stations, cabins buildings and other locations as indicated by engineer at site to a depth of 0.75 meters and supplying and fixing 50mm GI pipe The leading in arrangement shall be as per drawing no. RE/ S&T/ ALD/ SK/ 161/ 81.

1

5913

5913.42

... More
Excavation of pit and casting concrete foundation of apparatus case full size as per Drg. No. SK- 18/ 10 and fixing of 2 No. of 'E' type lock.

65

9250

601290.3

... More
Note: Data logger should confirm to clause 5.15 of RDSO/ SPN/ 192/ 2005 or latest & data logger Spec.IRS.99/ 2006 or latest. Modems required for networking of data logger shall be supplied by the contractor. Networking shall be preferably through E1 modems. The data logger shall consist of protocol converters and adequate capacity of digital and analog inputs. In case of distributed interlocking, data logger of adequate capacity shall be provided at Goompties also as per the instructions of engineer in charge. Net-working of Data logger to the control room shall be done by Contractor. A separate 80 column dot matrix printer/ laser jet printer shall be provided for each data logger as per the approved specification. The RTC of data logger should be updated/ synchronized with EI systems and it shall be possible to log the events in chronological order in case of use of either single/ multiple EI with Data logger. The data logger shall be inspected by RDSO

-

-

-

... More
(9) Fiber tape 3 meters - 1 No

-

-

-

... More
Training of Technician/ Jr. Engineers in installation, Testing, commissioning & trouble shooting of Electronic interlocking supplied against item no. - 1, 4&7 of supply schedule including supply of hard copies of course modules for each trainee.

0.5

48786

24393.12

... More
Airy Revolving and tilting working cushioned adjustable height chair with arm rests, polished black. The chair has plastic caned seat and back on 25mm round tubular frame. The base is of pressed sheet metal. Godrej/ zuari Make. Width 700 mm, Depth 700 mm, Height 870 mm, Adjustable seat height 410 mm to 520 mm, Colour Grey.

1

9472

9472.2

... More
(11) Pop spanner wrench 6mm to 22mm (auto adjustable spanner) Taparia make - 1 No

-

-

-

... More
Cutting of rock to a depth of 200 mm and width of 200 mm where rock is visible from surface to a depth more than 300 mm up to 550mm, excavation of trench with width 300mm above rock concreting 200mm x 200mm x 100mm after laying of cable with 1 cement: 2 sand : 4 graded stone aggregate 20mm nominal size and curing of concrete to the required number of days, refilling with excavated soil ramming and consolidation except in bridges, culverts, level crossings, track crossings, cable pits, rocky soil including marking of cable alignment, clearing of debris etc., complete to the finished item of work as directed by site in-charge. Drg No.SK/ CN/ NEW/ 3. All the material is to be arranged by contractor.

0.7

433382

303367.51

... More
Relay 'Q' series neutral line, AC Immune, plug-in type, Style `QNA1'. DC Neutral line, 24V, 8F/ 8B contacts, front and back contacts metal to carbon with plug board, retaining clip & connectors conforming to BRS:931A, IRS:S 67/ 88 amendment 2

95

5012

476225.5

... More
Erection of full location box on foundation including fixing of `E' type lock & locking arrangement, wiring, testing & commissioning as per approved disposition plan & wiring diagram. This also includes:

65

6966

452795.85

... More
Cable jointing details

-

-

-

... More
d) Copper strip of 300X25x6mm (MEEB)-1 No.

-

-

-

... More
Supply, Installation, Testing, Commissioning and Integration of the complete System of Microprocessor Based Networkable Analogue Addressable up to 64 nodes 1 Loop Fire Alarm control Panel With Minimum 320 Character LCD Display the panel should be equipped with sufficient nos. of loop. (As per RDSO Specification No. RDSO SPN217/ 2016 ver 1.0 or latest). Supply of 06 multi detector, 01 Hooter & Strobe, 01 Analogue Addressable Manual Call Point With integral short circuit isolator, analogue addressable protocol having status LED for alarming & standby mode. Electronically addressed, 01 FRLS armoured cables & power with all accessories for connection of all Fire alarm devices.

2

309089

618178.94

... More
Signal lighting circuit

-

-

-

... More
Supply of VHF mobile transreceiver simplex, 5 watts in freq. range 136 Mhz to 174 Mhz in 16 channel similar to Motorola model no. GP 328. with rechargeable battery from S.no. 1 to 16 of list attached may be programmed in VHS set 5W. (Supplier shall obtain licence for spot frequencies from WPC for railways).

8

25451

203610

... More
Supply and Installation of Signal Mesh as South Central Railway Practice

5

752

3762.4

... More
Dedicated reliable and branded DC-DC Converters for central EI and object controllers as per RDSO Specification/ Technical Advisory notes shall be provided by the contractor. Stabilized 230V AC/ 110V DC will be arranged by Railways. The DC-DC Converters used for EI and object controllers shall be in N+1 configuration. Safety factor of 1.5 shall be considered while calculating the load of EI and object controllers. Segregation of DC-DC converters shall be made between system A & System B so that, in case of failure of any DC-DC converter, only one system will be affected. The DC-DC converters shall be inspected by RDSO. This includes supply of DC-DC converters required for the EI system/ object controllers at Stations and mid-section Goompties.

-

-

-

... More
Integrated LED Based Signal for Main Aspect Signal with-in built current regulator as per RDSO Specn. No. RDSO/ SPN/ 199/ 2010 (Rev .1). It shall be suitable to CLS as per Drg. No. SA-23002 & as 23024/ M with latest amendment for Yellow aspect

26

9705

252347.42

... More
Supply of 50 pair krone type DP box with locking arrangement

4

9602

38408.68

... More
Electronic magneto telephone desk type as per RDSO Specn. No. IRS:TC-79/ 2000( Amendment-1 or latest).

3

3946

11839.38

... More
(22) Box spanner for 6 way terminals (13mm) (for opening ARA terminals) - 1 No.

-

-

-

... More
Supply of PVC conduit pipe 25 mm as per ISI mark

1

49434

49434.07

... More
(6) Side Cutter (wire cutter) 6" (Taparia ) - 1 No.

-

-

-

... More
Position light shunt signal unit without lamp holder unit, lenses & lamps to RDSO drg.No.SA-23840(adv.).

-

-

-

... More
Cable corage plan

-

-

-

... More
Integrated LED Based Signal for Main Aspect Signal with-in built current regulator as per RDSO Specn. No. RDSO/ SPN/ 199/ 2010 (Rev .1). It shall be suitable to CLS as per Drg. No. SA-23002 & as 23024/ M with latest amendment for Red aspect

26

10006

260179.14

... More
* Above items includes suitable cabinet for storing tools to ensure longer life.

-

-

-

... More
Cable termination details

-

-

-

... More
Non-Split double wall corrugated (DWC) pipe of HDPE Confirming to IS:14930 part-II, with threaded coupler, of Size 120mm outer dia and 103 mm inner dia

300

190

57228

... More
Colour Light Signal Unit 3 Aspect complete without signal transformers, lenses & lamps , suitable for 140 mm dia.post as per drg.No.SA - 23003 A/ M (Adv.) alt.9 & Specn. IRS-S-26/ 64.

-

-

-

... More
a. Digging/ Auguring/ Boring of single earth pit of 100mm to 125 mm dia to the depth of approx. 2.8 meter.

-

-

-

... More
Fixing & wiring of track circuit equipment such as battery chargers, track feed resistance, `B' type choke, track relays in location box as per SC Railway practice and Technical specifications para 34 and approved wiring diagram . This includes :- i) Supply, fabrication & fixing of duly varnish teakwood planks 25 mm thick for placing track charger, choke, batteries. ii) Supply of fixing material. iii) Installation of batteries in separate box as per drg. no. SC railway practice. iv) Painting and numbering of Track circuit. v) Charging of track batteries

5

5692

28460.65

... More
Supply of Electronic locator for locating buried electronic markers including disk type and spherical type markers, Capable of detecting seven electronic marker types with scan mode& identify which type of marker has been located. With advance pin ponit feature.

1

388279

388279.18

... More
Fixing of terminals, fuse blocks, N.D. fuses, etc. as per SCR railway practice.

-

-

-

... More
Supply of PVC casing-capping 25 mm ISI make as per site requirement. (As per instruction of site engineer)

1

67432

67432.58

... More
(20) Multi colour torch light ( preferable LED rechargeable type) - 1 No.

-

-

-

... More
(12) Pop spanner wrench 10 mm to 30 mm (auto adjustable spanner) Taparia make - 1 No

-

-

-

... More
Supply of managed SDH STM-1 ADM confirming to TEC specification no. GR/ SDH-04/ 03 MAR 2005, with (L1.1) aggregate optical interface, order wire, fully wire and equipped for 21E1 & minimum 4/ 8 port (50% BoQ Quantity 4 port & 50% BoQ Quantity 8 port) 10/ 100Base T electrical interface (with LCAS and GFP) and upgradeable to full 63E1s with all common cards, DDF and all other accessories, manuals etc., with required software. It shall be equipped with redundant power supply card. It shall support a minimum of 3 Nos. of E3/ DS3 in a single card and the selection shall be software configurable

1

273197

273197.82

... More
i. 300X300X300 mm (inside dimension) concrete earth pit with a concrete lid, approx 50mm thick with pulling hooks, shall be provided to cover the pit. Back side of the cover will be painted in black and dare of the testing and average resistance value shall be written.

-

-

-

... More
Supply of EC socket box to RDSO drg no. 15220 with socket six pin flat to RDSO spec. Nos.IRS: TC-42-87, amendment-1 or latest

6

1832

10994.16

... More
Supply and installation of MCB 2pole (32Amp)

1

998

998.08

... More
(ii) Supply of cement, sand, stone chip & mixing in the ratio 1:3:6.

-

-

-

... More
LED Based Signal for calling on signal conforming to Indian Railway chromaticallity standards and RDSO Specn. No. RDSO/ SPN/ 153/ 2011 REV.-4.1 with latest amendment. (This item includes fuses and other accessories required for fixing)

3

9371

28114.56

... More
Supply of double key lock. Godrej/ Harison make

2

908

1817.58

... More
(16) Chisel 6" (for cutting bond wire) - 1 No.

-

-

-

... More
Tool kit for Digital Axle Counter as specified by Original Equipment Manufacturer

1

170150

170150.15

... More
Fabrication and supply of GI termination box for point machine of size 45cm x 23cm x 12 cm, the termination box to be fabricated out of GI sheet 10SWG.

60

3734

224098.2

... More
Supply of 19" - 42U covered rack, vero president/ Rittel make or similar with Glass front door complete with all fittings for housing SDH equipment, primary muxes, DDF, MDF using Krone module, cooling fan and other equipments like runway ladders etc. completely wired and equipped with integrated protection modules for all channels as per technical specifications and other stipulations of tender document. It should be possible to lock all the equipments with only order wire telephone remaining outside the rack.

2

53554

107109.34

... More
Supply & fixing of Fire Extinguisher CO2 Type (capacity 4.5 Kg)

5

6123

30615.5

... More
Channel bond pin single groove as per RDSO Spec: S-17/ 75

25

3

87

... More
1x10 sq mm. (multistrand flexible wire)

30

7153

214599.6

... More
h. Routing and termination of two 35 sq mm earth conductors in trench from earth pit to 300X25X6mm MEEB, which is to be fixed inside the equipment room with two insulation studs.

-

-

-

... More
Fuse block made of PBT as per Specn. No. IRS-S-75/ 2006(Alt-4)) and Drg. No. SA-23748.

500

184

92115

... More
Fixing of 24 fibers FMS in Rack and termination of 24 Fibers in FMS and also connecting with Pig Tails. All fixing materials will be provided by contractor free of cost.

1

15063

15063.75

... More
Erection of Relay rack 1way with scaffolding suitably concreting tri-pod bases using J-bolts, fixing rack supporting of size 50x50x6 mm on to the wall. Reel insulators are to be provided for insulating the rack from the scaffolding & tri-pod bases. (payment based on number of equivalent 1 way relay racks).

6

2214

13289.64

... More
12 core x 1.5 sq. mm.

187

254643

47618255.96

... More
Supply of Low maintenance lead acid stationary secondary cells of 2V/ 80 AH along with connecting links, floats & insulators as per RDSO specification No.IRS-S-88/ 2004.

15

2731

40979.4

... More
Signal post 140 mm dia 4.5/ 5.5 mtrs. long to IRS-S-6-81.

-

-

-

... More
Relay Rack assembly complete with fixtures for mounting point group relays in EI Hut with all accessories like scaffolding, ladder, runway for indoor cables/ wires along with mounting arrangement as per drg. No. S&T/ MFT/ 291.

6

19533

117200.94

... More
(23) Nylon brush (for cleaning purpose) - 1 No.

-

-

-

... More
d. Carrying out exothermic weld connection on single earth electrode to a copper tape of 150X25X6mm.

-

-

-

... More
SMPS based Integrated Power Supply as per RDSO Specification No. RDSO/ SPN/ 165/ 2012 (Ver 3.0) with latest amendment & as per technical specification along with LMLA Battery Bank of 300AH Confirming to RDSO Spec. No. IRS:S93/ 96(A) Amndt.-1 or latest & Battery rack (IPS Configuration shall be as per technical specification) Note: contractor shall get approval for size and module from Engineer In charge. FOR 6 LINE STATION

2

1224931

2449862.08

... More
Supply of VHF transreceiver set simplex, 25 watt in freq. range 136 Mhz to 174 Mhz in feet support pipe and 30M RF cable. This shall also include the Power supply for 25W

1

47690

47690.84

... More
Excavation of trench to a depth of 1200mm and width of 300m at bottom in hard murum soil as per RDSO Sketch no SDO/ CABLE LAYING/ 003 including marking of cable alignment, clearing of jungle, bushes, trial pits if required, refilling with excavated soil, ramming and consolidation after laying of cables complete to the finished item of work as directed by supervisor in-charge

5.5

129409

711751.81

... More
Strengthening of foundations of signals, Full/ Half location boxes, by carrying out the earth work around the foundation, ramming of the earth, caring out masonry work from bottom of earth work using country stones and cement masonry to prevent the earth from slipping down the bank.

30

3351

100551.3

... More
Termination of outdoor cables, main cables laid in location boxes and Cable termination rack etc. at both ends. Both ends of a cable core terminated shall be counted as one termination. The item includes dressing of cable after termination.

6000

11

71400

... More
Non-Split double wall corrugated (DWC) pipe of HDPE Confirming to IS:14930 part-II, with threaded coupler, of Size 200mm outer dia and 175 mm inner dia

1000

455

455010

... More
Installation & Wiring of reset box/ verification box

-

-

-

... More
Installation of complete system STM1/ OFC and PD MUX and programming the system as per site engineer requirement all fixing material supplied by the contactor free of cost.

1

21177

21177.61

... More
Washers - 8 Nos.

-

-

-

... More
Hiring of vehicle for Railway personnel for NI

2

4339

8678.42

... More
Location box details with location wiring diagram.

-

-

-

... More
All the materials required for provision of VDUs in Dy. SS/ SM Room shall be provided by the contractor including connecting cables, power plugs, connectors, Tables/ Stands, nuts and bolts.

-

-

-

... More
Supply & Placing of electronic cable route marker on OFC cable route at the interval of 50 meters as per direction of site Engineer.

320

1852

592668.8

... More
Supply of block proving by axle counter (BPAC) using UFSBI as per RDSO Spec No. RDSO/ SPN/ 188/ 2004 with latest amendment for single line operation. Each set consists of the following items: (I) Universal Fail Safe Block Interface (RDSO/ SPN/ 147/ 2005 with latest amendments) - 2 Nos. (II) SM'S panel (RDSO/ SPN/ S/ 32019-tentative) - 2 Nos. (III) RELAY RACK with due locking & sealing arrangements duly wired, wiring as per RDSO/ S/ 32020-tentative - 2 Nos (with relay & relay base etc.) (IV) block telephone as per RDSO/ SPN/ 191/ 2006 - 2 Nos

1

1172775

1172775.55

... More
Supply of Digital transmission measuring kit confirming to RDSO spec no.IRS TC 43/ 97 or latest AP Lab make

1

57113

57113.71

... More
Track feed battery charger 110 V AC/ 2 - 6 V DC - 10 amp charging rate suitable to charge 1, 2 or 3 cells of 80 AH, to IRS-S-89/ 2013 ver 3.0.

5

7070

35353.8

... More
Supply of basic material to construct unit maintenance free earth consisting as per RDSO spec no. RDSO/ SPN/ 197/ 2008

30

27934

838044.3

... More
1. Installation of single earth(maintenance free) including the following:- welding and fixing of copper tape (used as bus bar) welding of cadmium bronze cable to copper plate using material supplied vide item no. 1, 2 of SPD of Sch-A. All the material supplied for mounting of copper tape, exothermic weld materials, tools and fixtures for welding copper tapes shall be arranged by contractor.

25

18841

471037.75

... More
e. Carrying out exothermic weld connection on the copper tape of 150X25X6mm on earth electrode for connecting two 35 Sq mm cables for redundancy.

-

-

-

... More
Fixing/ laying of DWC pipes in trench for laying of cables (including underneath the track, Road crossing or other platform cutting etc.) as per SCR practice and instruction of site engineer.

2000

72

144360

... More
Supply of Electric point operating machine IRS type (AC immunity 160 V AC) non trailable, to operate on 110 V DC complete with lock, detector, cable termination box and slides for lock and detector- rotary locking, universal type as per specification IRS-220 mm throw & Clamp point Lock 60Kg TWS as per Drg. No. RDSO/ S-11000 & RDSO/ S-3395 including Ground connection (RDSO/ S3454/ Alt-A) SUITABLE FOR IRS-220 mm throw & Clamp point Lock 60Kg TWS as per Drg. No. RDSO/ S-11000 & RDSO/ S-3395. It shall also include all necessary nylon insulators for insulating connecting rods from Rails and point machines.

1

170794

170794.42

... More
PVC insulated Railway signalling indoor single core cable as per colour coding scheme of Railways confirming to RDSO Specification No: IRS-S-76/ 89 amendment-3.

-

-

-

... More
Shunt signal surface base 90 mm dia drg. No. S-2011.

-

-

-

... More
Testing and commissioning of EI system at a station as a whole including outdoor gears. All artisan staff and labours required for testing and commissioning of EI with MACLS work shall be provided by contractor for indoor and outdoor work. Testing equipment such as simulation panel, signal and point operation simulation arrangement, multimeter etc. shall be provided by contractor at his own cost. Testing shall be carried out by contractor in presence of engineer-in-charge up to his satisfaction and necessary alterations shall be done. Contractor shall depute sufficient staff to carryout outdoor work during commissioning for completion of work within stipulated time.

2

808481

1616963.16

... More
Supply & fixing of hylam sheet, resin bonded 6 mm thick grade P3 for fixing terminal, fuse blocks etc.

-

-

-

... More
b. Insertion of 3.0 meter electrode and penetrating it at least .2 meter by pushing gently with sledge hammer where the natural soil is assumed.

-

-

-

... More
Supply of Automatic fusion splicing machine fully automatic RTC microprocessor controlled (Arc fusion type) with automatic selection of fusion current and warm image sufficient no. of splice protection sleeves and isopropy alcohol to be used for splicing

1

370261

370261.73

... More
Calling on signal unit position light type complete with mounting socket to Drg No. SA-24351 (Adv) or latest, specn. No. IRS-S: 10/ 78, IRS-S: 26/ 64.

3

5843

17531.16

... More
Cutting of rock to a depth of 200 mm and width of 200 mm where rock is visible from surface to a depth up to 300 mm, excavation of trench with width 300mm above rock concreting 200mmx200mmx200mm after laying of cable with 1 cement: 2 sand : 4 graded stone aggregate 20mm nominal size and curing of concrete to the required number of days, refilling with excavated soil ramming and consolidation except in bridges, culverts, level crossings, track crossings, cable pits, rocky soil including marking of cable alignment, clearing of debris etc., complete to the finished item of work as directed by site in-charge. Drg No.SK/ CN/ NEW/ 2. All the material is to be arranged by contractor.

1.2

572774

687329.98

... More
Supply & fixing of hylam sheet, resin bonded 6 mm thick grade P3 for fixing terminal, fuse blocks etc.

-

-

-

... More
Excavation of pit, casting & plastering of concrete foundation for shunt signal. As per Drg. No.SK-16/ 10 and Technical Specification. . This includes :

57

5447

310495.53

... More
Supply, Installation and wiring of Shunt Permitted Indicator (SPI) with all accessories

4

7355

29422.72

... More
Cable unarmoured PVC insulated multi core unsheathed with plain annealed copper conductor as per colour coding scheme of Railways in accordance with Specification No: IRS-S-63/ 2014 & 1554(Part 1) rev 4.0

-

-

-

... More
On straight

3

5488

16464.9

... More
Tools and measuring instruments required for maintenance of EI shall be supplied by the Contractor. Contractor shall list out tools and measuring instruments in the tender document. One set of Tool kit for each EI station to be provided.

-

-

-

... More
16 x 0.2 mm.(Red & Black)

180

813

146354.4

... More
SCHEDULE - E TELECOM SUPPLY

-

-

-

... More
Laying of S&T cables of various cores/ pairs/ quads in trenches/ GI pipes/ DWC pipes/ trunking. This also includes laying of cables in track crossings & road crossings. This also includes transportation of cable drums from contractors store to site for laying and provision of labels on each cable of coloured plastic adhesive tapes or any other identifiable material to give the cable number at each G.P.(Cables will be meggered before and after its laying by contractor under supervision of Railway Representative and he will submit the maggering report of each testing). Length of the cable laid includes the length of the cable coiled for termination purposes. This work is to be done as per tech. specification para.-17.0.

247000

9

2341560

... More
Independent shunt signal complete having following items.

57

9348

532860.51

... More
Cement concrete work for miscellaneous items in the ratio 1:3:6 Item includes excavation, ramming, curing and plastering with cement & sand mixture (Aggregate not exceeding 3.8 cm). Aggregate cement sand and holding down bolts nuts to be supplied by the contractor.

30

3375

101275.8

... More
(28) Wooden Block (60mm x 60mm) (for providing between Tongue rail & Stock rail during maintenance) - 1 No.

-

-

-

... More
Supply of cable termination racks (as per SC railway practice) size 880mm x 2 meter made out of 50mm x 50mm x 6 mm thick MS angle with stainless steel nuts and bolts for fixing of Rack with POWDER coating and drilling suitable holes to suite hylam sheet and relay frame complete as per standard practice with tripod basis reel insulators (for K rack, P rack and power rack) and with cable ladder of width 400mm and length of 2 meters. The thickness of angle to be 5 mm. Two angles of 40mm x 40mm x 5mm to be supplied at both ends supporting flats of 25mm x 5mm.

6

18188

109128.06

... More
Incremental rate for signaling functions in EI SYSTEM over and above 650 functions under item 1 above

50

72070

3603509.5

... More
(21) Universal key - 1 No.

-

-

-

... More
Electrical point machine (Rotary Locking Type) nontrailable to operate on 110V DC complete with lock and detector slides and cable terminal box (suitable tool kit for each 8 Nos. of point machine) As per IRS-S-24/ 2002 (amendment -1).(tool kit to be supplied as per RDSO specs) including ground connection.

60

112069

6724195.8

... More
Junction type route indicator 2 way complete without lenses, lamp holders and lamps. to IRS-S-66/ 84 Amd -1 with RDSO drg.No.SA-23402 (Adv.) alt 2 or latest.

2

24382

48764.06

... More
VF Tapping Transformers as per the RDSO Spec. IRS TC 22-76 or latest RDSO specification., 1120:470 6 Quad to Block equipment

4

1534

6138.76

... More
Splitting of Armour of Optical Fiber cable at the end and Splicing of 24 fiber optic fiber cable and making the splice joint with contractor's own splicing machine and tools. Acceptance Test Procedure of SCR has to be followed of testing. Continuity of the OFC Armour should not be maintained

2

27114

54228

... More
LED based Signal lighting unit for Route Indicator with built-in current regulator as per RDSO Specn. No. RDSO/ SPN/ 153/ 2011 Rev. 4.1 or latest suitable for 110/ 100 V AC and to use with conventional/ LED ECR.

18

7954

143186.4

... More
Supply of Instruments/ Tool Kits for EI*

-

-

-

... More
4 nos of anchor bolts.

-

-

-

... More
Supply of P MUX With 4W/ 2W E & M card, subscriber loop interface card. Exchange loop interface card co-directional data card and ISDN interface card Spec No.:. IRS: TC 68/ 2012 1. Circuits in each cards: (a) 4W/ 2W , E & M, VF interface cards - 4 Circuits per cards (b) Subscriber loop interface cards - 4 Circuits per cards (c) ISDN interface - Two BRI Ports per cards (d) Exchange loop interface cards - 4 Circuits per cards (e) 64 kbps data interface cards - minimum of 8 ports per cards 2. In addition to Power supply cards & Health monitoring cards (if any), following are the minimum Quantity of Cards: (a) 4W/ 2W , E & M, VF interface cards – Min. 3 Cards (b) Subscriber loop interface cards - Min 2 Cards (c) ISDN interface– Min. 1 card (d) Exchange loop interface cards – Min. 1 Card (e) 64 kbps data interface cards – Min. 1 card

1

287594

287594.04

... More
Fitting and supply of suitable base plate with GI pipe suitable for 6 Quad cable of 1.5 mtr length to Rail post. Rail Post will be provided by RITES.

6

4663

27979.08

... More
(i) Supply of 4 nos. anchor bolts as per RDSO drawing no. SA-112A with nuts and washers.

-

-

-

... More
Fixing of terminals, fuse blocks, N.D. fuses, etc. as per SCR railway practice.

-

-

-

... More
Erection, testing and commissioning of MSDAC supplied, Schedule, The Scope of work include labour and supply of all required materials receive of equipment/ items and materials, unloading, subsequent handling at Site, Storage, preservation, erection, testing, Startup, Commissioning and performance Test confirming to Technical Specification and discussion their after, commercial terms and conditions and as per terms and conditions agreed, the price includes contractor’s all services/ Labour and facilities required for the job.

125

27684

3460526.25

... More
(31) Flat file 12" length x 1" width - 1 No.

-

-

-

... More
(33) Digital Megger

-

-

-

... More
f) Earth electrode and coupler along with earth enhancing compound material (10kg pack)

-

-

-

... More
Fibre glass Track Lead Junction Boxes as per Drg. No. CWM-00597 of FRP material to IRS .5.23 specification along with fixtures i.e., on MS angle 50x50x5 mm 0.9 meter long, two numbers of GI pipes of 25 mm dia of 500 mm long with nuts and bolts and (this includes gromite buses and dummies, 60mm PBT terminals).

15

1294

19419.6

... More
Supply of 10 pair PVC Switch Board Cable 0.5mm as per RDSO specification no. TC24:91 or latest.

250

98

24620

... More
Fixing of track transducers on the rails.

-

-

-

... More
Trenching under Rails for crossing the track(Track crossing) and refilling of trenches as per RDSO drawing No.SDO/ CABLE LAYING/ 009. The track crossing shall be done at right angles. The depth of cable trench shall be 1.2 Mtr. below the rail flange. The depth between top cable and the level of rail flange of the rail shall never be less than 1.0 Mtr. The ballast shall be Stored separately while making the trench and the earth soil shall be stored separately. While re-filling the trench, the earth soil has to be filled first to the ground level and the ballast has to be properly put in the track. this work has to be done under supervision of supervisor of S&T and supervisor of P.Way

700

392

274638

... More
Alteration to Software and wiring along with Testing and commissioning of El equipment for the second stage working of way side stations as per approved signalling Plans. This work includes necessary Design, alteration to the logic, wiring and testing and commissioning of system. This work also includes any alterations/ modifications required earlier phase in Logic circuits and VDU software for stage working.

1

3374941

3374941.5

... More
Supply of end stopper for above item no. 40 wago make or similar (Grey)

200

19

3992

... More
Painting of two coats of enamel paint over one coat of Red oxide primer on the following items after scrapping and cleaning of the surface wherever necessary. Primer & paints both Asian make are to be supplied by contractor. Location boxes to be painted inside & outside also. Work has to be done as Technical Specification.

-

-

-

... More
Installation, testing and commissioning of Data Logger which includes the software configuration needed, validation, taking test print, for networking for transferring the data to nominated location for monitoring and changing of EPROMS if any as per the instructions of the site in-charge, including alterations data base in HQ/ SSE offices where ever required.

2

33857

67714.42

... More
TSF jointing kit and 6 quad cable copper conductor size 0.9 mm suitable for covering 2T transformer as per RDSO specn no. IRS-TC77/ 2012 or latest amendment

10

2452

24523.5

... More
Fixing of EKT/ RKT relays at ASM Room/ in field in location boxes.

6

1454

8726.22

... More
Earthing and soldering of the cable armours in location boxes

160

152

24355.2

... More
Full Location box

65

1087

70675.15

... More
Routing and connecting of all the SPDs in the equipment room to MEEB with 16 sq mm copper cable using copper lugs with stainless steel nut and bolts for item procured against supply.

-

-

-

... More
Supply & installation of Magnetic sensor (proximity switch) for Door in relay rooms etc.

4

822

3290.04

... More
Maintenance terminal shall be Industrial grade Embedded fan less PC (Similar to Moxa V2406 or better as per approved specifications) with minimum 40 inches LED/ LCD/ Plasma monitor of make Delta/ BARCO/ Mitsubishi/ NEC/ Sony/ Panasonic/ Samsung connected to EI (To be supplied by the contractor) as per Rly. Bd. Lr. No. 2010/ SIG/ SGF/ EI (Ansaldo) dt.13.07.2012. Power Supply to maintenance terminal shall be through a branded inverter/ branded online UPS with back up of at least 4 hrs as per the instructions of engineer in charge. A laser jet printer of approved specification shall be supplied along with maintenance terminal

-

-

-

... More
b)Earth enhancement compound of RDSO approved brand supplied in sealed bags of min 10 Kgs-03 No.

-

-

-

... More
Bushes - 6 No.

-

-

-

... More
Fixing of Electrical Point Machine on the extended sleepers at points as per std. practice- and RDSO Drawings. This item also includes: 1. fixing of switch extension bracket('P' bracket) and ground-connections. 2. fixing nylon insulation for switch extension bracket, gauge tie plate, driving lug and P-way stretcher bars. 3. Adjusting opening of the switches to 115mm. 4. Testing of point machine as specified in technical specifications.

60

14172

850329.6

... More
Supply of Pigtail with FC/ PC connector single mode 10 meter long on both sides confirming to TEC specification no.TEC/ GR/ TX OFJ-01/ 05/ NOV-09 with latest amendment no. TEC/ T/ OFC-OFJ/ 155/ 2013.

10

2017

20173.4

... More
Design, prepare and supply of 6 hard copy of each following document with soft copies office document from gooty to dharmawaram section. a) cable route plane of 6 quad cable indicating km. no of derivation/ straight through cable joint and distance of cable laid from nearest center of track. b) Termination detail of 6 quad cable circuit wise c) cable route plane OFC 24 fiber OFC cable indicating km no. of derivation/ straight through cable joint and distance of cable laid from nearest center of track. Termination detail of 24 fibre cable circuit wise and also circuit detail of krone DP

2

6397

12794.4

... More
Supply of HDPE duct 40/ 33 mm as per TEC GR Nos. G/ CDS 08/ 02 Nos.v.2004 with latest amendment as available. For each Km. of HDPE duct following items are to be supplied a) End plugs-2 Nos. b) Cable sealing plugs - 2 Nos. c) Plastic couplers slip fit/ push fit type-2 Nos. d) End plugs to be provided along with drum - 2 Nos. immediately as and when required.

10

72643

726432.3

... More
Design & preparation of following drawing/ documents along with soft copy. (This item includes independent verification & checking by IRSE/ IRESETLO License holders) 1) SIP 2) Selection table, 3) Vital & non-vital I/ O Bit Chart, 4) EI configuration diagram, Equipment layout plan, Relay disposition chart. 5) VDU plan. 6) Application logic 7) Interface circuit with contact analysis. 8) Equivalent circuit of application logic. 9)CTR & Power rack particulars 10) Floor plan 11) Earthing plan

2

231234

462469.08

... More
Tool kits and Measuring Instruments for Technicians/ Junior Engineers for testing & maintenance and repair at site as specified by Original Equipment Manufacturer.

1

136103

136103.52

... More
Supply of 10 Sq mm Multi strand single core PVC insulated copper cable as per IS: 694 for connecting various equipments to SEEB.

110

124

13722.5

... More
(10) Scale 6" (for tongue rail opening) - 1 No (S.S. material)

-

-

-

... More
Erection of half location box on foundation including fixing of `E' type lock & locking arrangement. Relay wiring, testing & commissioning as per approved disposition plan & wiring diagram. This also includes :

12

6315

75786.6

... More
Supply of 10 Pair copper conductor size 0.63mm PIJF UG Cable as per RDSO Spec No.IRS TC 41/ 97 or latest

1

315476

315476.17

... More
Installation of VHF transreceiver set simplex, 25 watt in freq. range 136 Mhz to 176 Mhz in 16 channel similar to Motorola model no. GM 338 with suitable antenna attached to 12 feet support pipe and 30M RF cable. This shall also include the Power supply for 25W radio (12V/ 15Amp) with Sealed maintenance free battery (65AH) and one BNC to VHF adapter. All fixing material will be supplied by the contractor free of cost.

1

10433

10433.94

... More
Bunching of cables with PVC tape including supply of ferrules, tape, cable fixing clamps etc.

-

-

-

... More
Excavation of pit, casting & plastering of concrete foundation for C.L. Signal & ladder as per Drg.No. SK-15/ 10. This includes: Supply of cement, sand, stone chip 20 mm & mixing in the ratio 1:3:6.

24

9344

224270.88

... More
Excavation of pit and casting concrete foundation of apparatus case half size as per Drg. No.SK-17/ 10 and fixing of 2 No. of 'E' type lock.

12

8494

101934.96

... More
c) Supply & Installation of Dual VDU's based control terminal with 4K resolution minimum 55 inches (LED/ Plasma) monitor of Mitsubishi/ BARCO/ Delta/ NEC/ Sony/ Toshiba/ Panasonic/ Samsung make (preferably Industrial grade) for operation and indication of various functions with fan less embedded industrial grade computers (Similar to Moxa V2406 or better) as per approved Specification. Connectivity to the EI shall be either on Ethernet or through optical fiber cable. However, optical fiber cable is preferred medium. Suitable arrangements shall be made to fix VDU`s and reset boxes etc. in the Dy.SS/ SM room as per the instructions of Engineer in charge. Uninterrupted power supply arrangements either through branded inverters approved by RDSO or through commercial branded on line UPS with minimum 4 hrs back up as per instructions of engineer in charge for VDU’s shall be provided by the contractor. Railway will provide 230V AC/ 110V DC. Key board and mouse provided with the operator VDU shall be industrial grade. It shall be possible to scroll the yard in case of big yardsrial grade computers as per approved Specification.

-

-

-

... More
LED signal lighting unit for shunt signal conforming to Indian Railway chromatically standards and RDSO Specn. No. RDSO/ SPN/ 153/ 2011 REV.-4 with latest amendment (This includes fuses and other accessories required for fixing)

226

7832

1770185.68

... More
(30) Tester - 1 No.

-

-

-

... More
Erection of rail post with emergency socket this include cutting of rail to required size, supply and welding of GI Pipe and base plate on rail post, fixing of emergency socket box and termination of 6 quad/ PIJF cable on the strip of 6 pin emergency socket in side emergency socket box as per drawing no .SK/ CSTE/ C/ 97/ 16 & SK/ CSTE/ C/ 97/ 20.Suitable Foundation will be prepared as per standard practice of south central railway. The contractor will arrange transportation of the all material as each emergency socket post location by his own cost in the section.

6

9430

56584.56

... More
9. DC-DC convertors (input voltage 110 V DC and output voltage as required) 10. All types of indoor wires as required. 11. All types of indoor terminals and fuses as required except terminals for main CTR. 12. Racks for mounting EI equipments and interfacing relays. 13. Termination rack for indoor cables. 14. Fixtures, mounting arrangements, Ladders for wire run and other accessories as required. 15. Softwares used for maintenance, data logging and fault diagnosis etc of EI system. 16. Protective devices like lightning protectors for DC and AC supplies, isolator/ convertor for serial communication etc. 17. 3 sets of documents and manuals as per RDSO specification para 10.1 in three sets. 18. Ring Earthing and EMI shielding of EI room. 19. Inverters of reputed make for VDUs supply as per TAN. 20. Any other item contractor feels necessary as per their system. 21. Completion plan of stations. 22. UPS with 4 hrs back up for maintenance VDU.

-

-

-

... More
Termination of cables and wiring in way side electronic unit.

-

-

-

... More
Insulating plate - 2 No.

-

-

-

... More
Supply of FCPC To SCPC 10 meter long patch cords with o db adaptors as TEC spec G/ OJC-01/ 03 JAN99 or latest RDSO specification.

10

4645

46450.9

... More
Item includes supply, fixing and wiring of push buttons and LEDs for EKT/ RKT circuit. The EKT/ RKT relays, push buttons, LEDs to be fixed on the wooden box inside the ASM room.

-

-

-

... More
Supply of Hand held Digital multimeter with leads, 3 1/ 2 digit Rishabh 15 s

1

11015

11015.57

... More
ARA terminal 6 way, made of PBT as per drawing No. 23756 (adv.) Alt3 confirming to RDSO specn. No.IRS-S-75/ 2006 (Rev.2 or latest) with latest amendment

1600

372

596752

... More
NOTE: The above mentioned 1 item shall include the following items:

-

-

-

... More
Thermo Shrink joining kit suitable for 6 QUAD jelly filled cable-straight through specn. No.IRS-S-TC-77/ 2006, rev 3.0 amnd.-2 or latest.

10

3212

32121.7

... More
C.T. Rack details

-

-

-

... More
Painting of two coats of enamel paint black Asian and Aluminium white as approved by Site engineer over one coat of primer on Main signal post with signal unit, surface base complete with route indicator, subsidiary signals, ladder fittings as per Indian Rly. standard practice. Work has to be done as per SC Railway practice.

24

1052

25267.2

... More
Screw less rail mounted 2.5 sq mm 4 conductor, 2 in' 2 out disconnect terminal block front entry cage clamp of wago make or similar. This item includes Supply of marker strips.

1500

67

100755

... More
Filling up pit inside the location box by sand and plastering on the top of the sand.

-

-

-

... More
Track feed variable resistance (with phenolic moulded base) 30 ohms to suit RDSO drawing number SA20166-66/ M.

5

414

2072.7

... More
Supply, installation of earth electrode as per SCR drawing no. G/ SG/ 09/ 2002, and connecting to location boxes Signal Units, Power equipments, Cables etc. With 35mmX6mm Ms flat

160

4023

643828.8

... More
Painting of two coats of enamel paint black Asian and red oxide as approved by Site engineer over one coat of primer on point machine and ground connection respectively. Work has to be done as per SC Railway practice.

58

602

34936.3

... More
Erection of surface base, shunt signal post, shunt signal unit and number plate.

-

-

-

... More
Erection & wiring of independent shunt signal. This includes:

57

836

47669.67

... More
Installation, testing and commissioning of 48V, 50 amps battery charger & battery for telecom use as per direction of site Engineer. All the required fixing hardware material will be arranged by contractor free of cost.

1

8723

8723.46

... More
Track bonding plan

-

-

-

... More
Supply of Digital insulation tester RISH INSU 10 (magger)

1

8714

8714.87

... More
(26) Feeler gauge - 1 Set

-

-

-

... More
Bushes - 4 No.

-

-

-

... More
Track crossing by horizontal boring method based on SC Railway practice and as advised by the engineer at site. This includes the supply and insertion (pushing) of GI pipe (80/ 100/ 200mm) confirming to IS.1239 heavy class in the bore drilled with the coupler between two pipes. All the joints of casing pipes should be tight and leak proof.

100

2387

238798

... More
CLS ladder complete with platform and base 4.5 mtrs. long to drg.No.SA-23153 (Adv.) Alt 1.

-

-

-

... More
Various types of markers as Signal number plate as per drawing of SCR, 3mm thick white laminated MS sheet shall be used. Letter shall be written in black on yellow background.

105

453

47615.4

... More
Supply of carrier rails of dimension 35mm x 7.5mm, 1mm thickness unsloted type for above item a) wago make or similar. Note: Carrier rail shall be 1mm thick without slot for above blocks. (Length of each piece shall be 42.8 cms/ as per site incharge)

100

114

11407

... More
Relay 'Q' series neutral line, AC Immune, plug-in type, Style `QBCA1'. DC Neutral line, 24V, 2F/ 4B contacts, front and back contacts metal to carbon with plug board, retaining clip & connectors conforming to BRS:931A, 933A, 932A, 935A 937A 960 & RDSO/ SPN/ 84 ver 2.0

42

6994

293753.04

... More
Supply of High availability SSDAC with redundancy as per RDSO Specn. No. RDSO/ SPN/ 177/ 2012 ver 3.0 including all the fastening and mounting arrangements & as per Technical specification.

2

821949

1643898.44

... More
ARA terminal 1 way, made of PBT as per drawing No. 23746 (adv.) Alt5 confirming to RDSO specn. No.IRS-S-75/ 2006 (Rev.2 or latest) with latest amendment

150

72

10876.5

... More
Supply & installation of Universal Earth leakage detector of 8 channels (AC/ DC) as per RDSO/ SPN/ 256/ 2002.

2

119367

238734.76

... More
CLS ladder complete with platform and base 4.5 mtrs. long to drg.No.SA-23153 (Adv.) Alt 1.

-

-

-

... More
(7) Nose plier 6" (Taparia) - 1 No.

-

-

-

... More
Supply of Data Logger with power supply arrangements complete as per RDSO specification No. IRS-S-99/ 2006.(amd-3) as Technical Specification. (1) Data logger shall have the following module: (i) Processor module (ii) Input module (Digital/ Analog), (iii) Signal conditioning module, (iv) Printer 80 Col. Dot matrix. (2) The equipment shall cater for minimum 512 digital inputs (in the form of voltage free contacts) and 32 analog inputs. The system shall be expandable up to 4096 digital and 96 analog inputs by expansion/ cascading the similar equipment.

2

456342

912684.36

... More
g. Digging a trench to a depth of at least 0 .5 Mtr. and run the two 35 Sq mm earth conductor (procured against supply item) from earth pit to MEEB.

-

-

-

... More
Installation of way side electronic unit.

-

-

-

... More
Integrated LED Based Signal for Main Aspect Signal with-in built current regulator as per RDSO Specn. No. RDSO/ SPN/ 199/ 2010 (Rev .1). It shall be suitable to CLS as per Drg. No. SA-23002 & as 23024/ M with latest amendment for Green aspect

2

11581

23162.86

... More
Various types of markers as P markers as per drawing of SCR, circular disc made of 3mm. thick white laminated MS sheet shall be used. Letter 'P' shall be written in black.

2

436

873.84

... More
(27) TSR Meter (for testing condition of track circuit) - 1 No.

-

-

-

... More
Fixing of hoods and LED lamps.

-

-

-

... More
PVC insulated armoured, unscreened, underground railway signaling copper conductor cable confirming to RDSO specification No. IRS:S-63/ 2014 with Amendment -2 or latest of sizes:

-

-

-

... More
Fixing of conduit pipe/ PVC channel as per direction of site engineer. All fixing material will be supplied by the contractor free of cost.

500

9

4720

... More
Erection of surface base, signal post, signal unit, signal number plate, ladder with guard & platform. This item also includes erection of junction type route indicator, shunt signal on offset bracket, calling on signal, P/ C/ G marker & blanking-off signals where required.

-

-

-

... More
Temporary accommodation (Hotel room) during line block/ NI for Railway personnel

2

3374

6749.88

... More
Installation, testing and commissioning of 4 wire control telephone as per direction of site engineer. All fixing material will be supplied by the contractor free of cost.

2

2609

5219.72

... More
Colour light signal (3 aspect) complete set as per drg.No.SA23002 A/ M (adv.) alt.9 & Specn. IRS-S-26/ 64 consisting of the following items :

2

33904

67809.64

... More
Key lock relay with 1 No. K 50 (N) relay to operate on 24V DC, 4F/ 4B or 2F/ 2B contacts (should be confirm by Engineer in charge before supply) confirming to IRS: S-46, IRS: S34 & IRS: S23 (as applicable) and firm's specification. Crank handle keys to be provided with different ward combination for each crank handle group and matching sockets on the point machines. Its include KLCR box as per the design approved by Engineer In-charge.

20

8663

173270.6

... More
Shunt signal post 90 mm dia 1m long to IRS-S-6/ 81.

-

-

-

... More
Channel side plate RH -2 No.

-

-

-

... More
(1)Standard Tool Bag (CANAVAS) - 1 No.

-

-

-

... More
Manufacturing and fixing of glass fronted box (key box) made out of teak wood of size 10 inches x 16 inches.

2

1778

3556.68

... More
a) copper bonded steel electrode of 3.0m long, 17.0 mm dia with copper bonding thickness mini 250 micron and UL listed and marked-1 no.

-

-

-

... More
PVC insulated Railway signalling indoor single core cable as per colour coding scheme of Railways confirming to RDSO Specification No: IRS-S-76/ 89 amendment-3.

-

-

-

... More
(2) Soldering Iron (Make "Soldern/ Philips) - 60W/ 230V (to be kept at equipment room) - 1 No

-

-

-

... More
Design, preparation & supply of Six (06) hard copies of each documents along with soft copy for the mention below along with original tracing on a standard 7.5 micron polyester film in AUTO CAD FORMAT. (The item includes supply of two sets of drawings for approval and corrections thereon as suggested by RITES)

2

116857

233715.38

... More
Note: This work also includes carrying out necessary alteration in software, hardware, wiring, validation, testing and commissioning etc. of Dataloger to meet the requirements of the revised signalling Plan. This work includes FAT and SAT for EI for approval as per standard practice. Any other miscellaneous materials required for the work shall be supplied by the contractor. This work involves submission of 2 sets of documents (Wiring Diagrams, Application Program Listing, Relay/ Cable Termination particulars, Input/ output assignment details, Relay layout and contact analysis chart, Equipment disposition layout, Details of power supply arrangement, any other drawing as required by the Railway as per its practice, all documentations as per clause No. 10 of RDSO technical specification.) of EI for approval as per standard practice and 2 sets of documents required for Technical System Application (TSAA).

-

-

-

... More
Underground railway jelly filled 6 Quad cable for signalling & telecom installations confirming to IRS: TC-30/ 2005 (Ver. 1) with amendment-5A having 0.9mm dia copper conductor.

45

364165

16387449.3

... More
Various types of markers as C markers as per drawing of SCR, circular disc made of 3mm. thick white laminated MS sheet shall be used. Letter 'C' shall be written in black.

3

405

1217.19

... More
Cable route plan.

-

-

-

... More
Office Chair of continuous arms having cushioned seats and rest T.W. Arm rest size 36" x 21" x 22 approx steel tubular frame gauge of the pipes 25mm dia x 18 gauge with olive green colours, Green stove enamelled "Indian Make". Godrej/ zuari Make.

5

4141

20708.6

... More
Installation of krone DP 50 pair as per direction of site engineer all fixing material will be supplied by the contractor free of cost.

3

588

1765.23

... More
(4) Screw Driver set of 6 pieces (Taparia Make) - 1 No

-

-

-

... More
Non deteriorating type fuses as per IRS-S-78/ 92 with latest amendment. (20A, 16A, 6A, 4A, 2A)

500

29

14875

... More
Painting of emergency socket box rail post and marking socket no. each post as per south central railway practice and as per direction of site engineer. All required primer/ paint (nerolac/ ACAN/ asian paint) will be provided by the contractor free of cost.

8

658

5265.36

... More
Supply of Laptop based work station of latest configuration for data inputs, simulation and functional testing, diagnostics, trouble shooting and configuration of EI system (detail as given in TS), complete with necessary softwares preloaded.

1

140921

140921.93

... More
Supply of workspace make new modular control desk or similar for 2 monitors(minimum 54 " or higher size), 2 operators and 1 module will be provided for storage make in SLAT system with side drawer. (i) Desktop made of 12 mm ASS + 25 MM MDF with properties like - high scratch resistances, seamless joint, flammability class A, non-porous, (ii) structure - powder coated aluminum sturty structure and extreme side aesthetic legs, (iii) shutter- 18 mm MDF, (iv) proper cooling aggregement for CPU cabinet, (v) side out CPU tray, (vi) ergonomic design considering proper leg space, (vii) with cable arrangement, wire arrangement, provision for CBT,UPS,CPU , with complete wiring provision (viii) all electrical components as shown in drawing, other details shall be executed as advised by Railway representative.

1

222310

222310.87

... More
Supply of cement, sand, stone chip & mixing in the ratio 1:3:6.

-

-

-

... More
NOTE: 1. Material for installation like 10mm hylam sheet, GI pipes, MS pins, split pins, wiring materials, various fixing nuts & bolts including castle nuts, spring washers will be supplied by the contractor. 2. The ground connections shall be suitable to the Point Machines as specified by Engineer-in-charge and shall be suitable to the point lay out i.e. 60 kg as per yard layout. 3. Cable entry from junction box to point machine shall be made as per SC railway practice.

-

-

-

... More
Supply of Multi Lamp Route Indicator (LED double digit) for 1 to 9 (single digit) with white LED along with housing as per specification IRS: S 66/ 84 Amd. 1 or latest and drawing No. SA 23761 (Adv.) or latest. Lamp proving compatible with Normal bulb type multi lamp route indicators. Retrofits the existing conventional multi lamp type route indicators housing. Input operating voltage 110V AC +25%. Uniform intensity over entire operating range.

1

46771

46771.32

... More
Supply of universal locks with one key for every ten locks.

200

219

43828

... More
Bushes - 4 No.

-

-

-

... More
(ii) Supply of cement, sand, stone chip & mixing in the ratio 1:3:6.

-

-

-

... More
Insulation for gauge tie plate for BG as per IRS-S-40/ 84 with Amd-1 and SA-22171(alt-2) for 60 KG rail

60

399

23985

... More
Installation, of 19" - 42 U Rack with all fittings for housing SDH equipment, primary muxes, DDF, MDF using Krone module, cooling fan and other equipments like runway ladders etc. completely wired and equipped with integrated protection modules for all channels as per technical specifications and other stipulations of tender document. It should be possible to lock all the equipments with only order wire telephone remaining outside the rack. Configuration shall be decided as per site requirement. All required fixing hardware material will be arranged by contractor free of cost.

1

25314

25314.68

... More
Erection of cable termination rack complete along with wall support, ladder etc. as per Technical Specification. and SC Railway Drg/ practice This includes :

6

2030

12183.06

... More
23. Class 'A' type surge protection device protection at each SSI room/ goomty, mounting arrangements and accessories necessary to make the EI system functional. 24. Splicing of OFC to the EI system is in the scope of contractor. Note: 1. Supply of Optic Fibre Cable, 60Cx1mm indoor cable, IPS, KLCR, Main Cable Termination Rack & terminals for Outdoor cables and relay rack for mounting point relays are not included in this item. 2. Scope of supply shall not be limited to BoM given along with offer and all the materials necessary for successful commissioning of system shall be supplied without any extra cost in addition to the price offered for this item. 3. Quantity, item wise rates and total cost should be submitted by the EI Manufacturer/ Supplier by attaching as annexure.

-

-

-

... More
Relay, AC immune, plug-in type, style ‘QTA2’, neutral track, 9 ohms, 2F.1B contacts, front and back contact metal to carbon, complete with plug board, retaining clips and connectors confirming to BRS-939A, BRS-966 (Appendix S2),

5

4666

23334.8

... More
Installation, wiring, testing & commissioning of HA Single section digital axle counter. This includes following at both ends of track section/ block section:

2

35422

70844.6

... More
OFC tool kits with following items: 1. Branch Joint Closure 2. Termination Box 3. Rubber and Block 4. Sheath Clamp 5. Bushing 6. Strength Member holder 7. Heat Shrinkage tube 8. Power cord AC/ DC 9. Tube heater 10. Precision cleaver 11. Cable sheath stripper 12. Fibre stripper 13. Knife for HDPE cutting 14. Hacksaw for strength membrane 15. Isopropyl alcohol or methanol of high specific gravity 16. Johnson Buds 17. Tweezers 18. Gun heater blower type 19. Sleeve for splice protection 20. Stabilized optical power source and power meter 21. Stickers for numbering of splicers 22. Portable generator 23. Big Umbrella 2 Nos. 24. Dust protection for splicing machine 25. Tool box 26. Safety hand Gloves – 2 sets

1

188041

188041.31

... More
Supply of 35 Sqmm PVC cu cable

250

450

112712.5

... More
Providing brick masonry in ratio 1:6 cement and mortar including plastering with 1:4 cement and sand mixture both sides. 20mm thick each with contractor's own 2nd class bricks including excavation curing, grouting, bolting etc. Wherever required bricks sand and cement to be supplied by the contractor.

6

2847

17084.94

... More
Supply maintenance free VRLA secondary cells duly charged of 48V 200 AH and each 2.0 V when fully charged 200 AH capacity along with accessories i.e. intercell connectivity links/ float, 4 nos. insulators for each cell 24 nos. of cell per set as per RDSO Spcn.IRS/ S/ 88/ 2004 amendment - 1 revision with latest amendments with cuitble steel/ hylam tray battery rack to install/ house batteries

1

54000

54000.91

... More
c. Filling of earth pit with earth enhancement compound (EEC) in slurry from and backfilling.

-

-

-

... More
Various communication modules required for communication between EI, operator VDU, maintenance terminal, object controller and Data logger are to be supplied and installed by the Contractor. All communication modules shall be of industrial grade. Media (OFC only) will be provided by railways. Any media other than OFC shall be provided by the contractor. However OFC is the preferred medium.

-

-

-

... More
GI bond wire soft 8swg for binding as per IS-279

150

54

8125.5

... More
Painting of two coats of enamel paint over one coat of Red oxide primer on the following items after scrapping and cleaning of the surface wherever necessary. Primer & paints both Asian make are to be supplied by contractor. Location boxes to be painted inside & outside also. Work has to be done as Technical Specification.

-

-

-

... More
Key Lock 'E' type with key Drg.No.SA-3376/ M. Alt-2. Spec.No.IRS-S-30/ 64 different wards. Inspection by Owner's representative

86

1320

113571.6

... More
(13) Pop spanner wrench 15mm to 41mm (auto adjustable spanner) Taparia make - 1 No

-

-

-

... More
Installation of krone DP 20 pair as per direction of site engineer all fixing material will be supplied by the contractor free of cost.

6

362

2175.78

... More
55" VDU shall display the complete yard/ station as per rule diagram. Font size yard shall be clear, legible, bigger and font size of auto section signals shall be smaller without any hazy appearance of main yard.

-

-

-

... More
(i) Supply of nuts & bolts, MS clamps & cement for masonry works. (ii) Supply & fixing of hylam sheet.

-

-

-

... More
Fixing of angle iron frame for "Q" type relays in location box. This includes supply of angle iron for fixing relays wherever required.

-

-

-

... More
Supply and wiring of Push button phone for Auto, Hot line communication make Beetel or similar

2

4107

8214.3

... More
EI Hardware and Software shall be separate for Yard specific driving functions with hot standby for both

-

-

-

... More
Installation, wiring, programming, testing and commissioning of EI and other equipments supplied against supply) at "Station Building" & "One END Goomties", as per technical specifications. This also includes preparation of design documents and supply of materials for installation, wiring, grouting, cutting of floors, walls etc. refilling of same, replastering, required CC/ masonry works, termination of cables with lugs/ connectors, painting/ lettering on relay rack/ termination rack are to be done by the contractor.

1

899256

899256.39

... More
Plain storage almirah with 4 adjustable shelves size 1980mm height, 915mm width, 485mm depth, Godrej/ zuari Make.

1

21743

21743.52

... More
Breaking of metal/ tar road and refilling after laying the cables as per drawing no.SDO/ CABLE LAYING/ 010. The surface of the road shall be concreted to match with the old surface.

0.01

236907

2369.07

... More
Installation, testing, commissioning of UFSBI including relay wiring. This item includes fixing & wiring of relay, block phones and other equipments required for Block instrument. All fixing accessories are to be provided by the contractor, Including alteration in existing wiring in old relay room including relay wiring

1

58589

58589.69

... More
Installation, wiring, testing & commissioning of track circuit involving points & crossings as per track circuiting plan. The work includes testing of track battery after charging and installation. This work is including drilling 9/ 32" hole on rails; fixing of bonding(double) with 8 swg soft GI wire & jumper rope wire, fixing of track lead junction box, rail connector with GI wire, track jumpering as per site Engineer.

-

-

-

... More
Signal base Cast Iron 140 mm dia. to drg. No.S-2011/ M.

-

-

-

... More
HP business Desktop Intel Core i5-2400 processor, 500GB SATA HDD, 02 GB DDR 3 RAM, DVD R/ W Drive, 21"TFT Monitor, M.M. Keyboard and optical scroll mouse, 10/ 100/ 1000 Integrated LAN, Integrated 06 USB, Sound and AGP Ports on Board, Microsoft essential Antivirus software.

2

60282

120564.7

... More
5. Wiring inside the point machine, termination of tail cable in point machine and junction boxes. 6. Erection of junction box on M.S. angle of 50 x 50 x 5mm & 1 m length and fixing of M6 terminals on 10mm hylam sheet for cable termination. 7. supply and fixing of bend GI pipes for taking cable into point machine and junction box (Gland pipe) for points. 8. All black smithy & fitting works required at site for complete installation.

-

-

-

... More
Supply & Erection of sighting board as warning board/ Stop Board/ BSL/ Calling on instruction board etc as per SC railway practice

11

4484

49334.56

... More
Supply of 2 wire way station Equipment with DTMF signalling to RDSO Spec. No. IRS TC:60/ 2007 or latest

2

6383

12766.74

... More
Insulation for 'P' bracket for point machine as per Rly. design each set comprising of :

120

452

54313.2

... More
(25) Crimping Tool (1.5 to 16 Sq.mm) - 1 No.

-

-

-

... More
Excavation of trench to a depth of 1200mm and width of 300m at bottom in all types of soil(Normal soil/ soft soil/ sandy soil except in hard murum/ rocky soils/ bridges/ level crossings/ track crossings/ coil pits) as per RDSO Sketch no SDO/ CABLE LAYING/ 003 including marking of cable alignment, clearing of jungle, bushes, trial pits if required, refilling with excavated soil, ramming and consolidation after laying of cables complete to the finished item of work as directed by supervisor in-charge. NOTE: Supply of Cable markers, Supply and Laying of RCC Trunking & cappings are covered separately.

11

105640

1162050.67

... More
Supply of essential spares to the extent of 10% (other than the spares to be supplied under item no.1) subject to minimum one, for all types of cards/ modules, card cage, operating/ maintenance PC, connectors/ couplers, fuses, relays, timers etc. used in the EI system. It shall include spares f. List of spares to be supplied with unit rates should be given by the tenderer along with offer.

1

4523716

4523716.57

... More
Supply of Distributed Electronic Interlocking (Hot Standby) with dual VDU of 55" for Signalling functions up to 650 unit, as per RDSO spec no RDSO/ SPN/ 203/ 2011 Ver1 or latest 10% spares I/ O and to suit the signaling plan of stations. Scope of supply against this item includes all the indoor equipments necessary for successful functioning of distributed EI system, mainly consisting of but not limited to following, conforming to attached Technical specifications. 1. Microprocessor equipment. 2. I/ O cards with card cage and motherboard. 3. Power supply cards. 4. All types of connectors and couplers as required. 5. Industrial grade Dual VDU of 55". 6. Industrial grade PC & maintenance VDU of 40" 7. All types of relays required for interfacing. 8. ECRs suitable for LED signal lamps.

1

45237165

45237165.65

... More
Supply of GKP type Location Boxes half as per drg. No. S&T/ MFT/ 2378 (Half).

12

12171

146056.44

... More
Supply and providing of polymeric positive temperature co efficient device self resetting type (PPTC) suitable to railways

25

21

536.25

... More
Supply of Cable jointing tool kit consisting following items: 1.Tool Box for cable jointer 1 no. VIP or Alfa Make 2.Spitfire G.P. kit consisting of:

1

67871

67871.89

... More
04 nos. Anchor bolts complete (915 mm x 75mm x 24 mm) to drg.No.SA-116 A/ M & IRS-S-10/ 78 with latest amendment.

-

-

-

... More
Shunt signal dependent type drg No. SA-23840 (adv.) ) with offset bracket 3½'' dia. to suit 140mm. Outside dia post complete without lenses, lamps & lamp holders.

17

7355

125046.56

... More
Fixing relay bases on the relay frames erected in Relay Room, Wiring of all types of relays by drawing various sizes of wires/ multicore cable, fixing fuses, condensers, resistances, LEDs etc and wiring duly soldering the same as per approved circuit diagram, testing point to point before soldering and after soldering, bunching and lacing as per detailed technical specification. Different colour codes and sizes of wire to be used as per standard practice. This also includes, provision of all PVC sleeves required to be provided. Copper lugs to suit to 16/ 02 wire and neat bunching, lacing with Modi Nylon/ Twine thread and using PVC dotted tape with buttons were required. This also includes soldering all the wires in the relay room with Rosine core of IS Spec. 1921 (60% Tin and 40% Led). Soldering should be done as per standard practice. This also includes inserting the clips, point to point testing as per the circuit diagram and plugging relays to Relay bases (except Inter-cables, relays other materials such as Rosine core, flux, nylon thread. PVC dotted tape should be supplied by the contractor). Point to point testing should be done in the presence of Engineer-in-charge as instructed in two stages, one before soldering and the other after soldering.

100

361

36196

... More
Supply of XLPE insulated, PVC sheathed aluminum conductor, armoured power cable 2c x 70 Sq.mm as per IS:7098/ Pt.-1.1988

6

243045

1458270.72

... More
f. The exothermic welding material for bonding the earth system shall be procured from RDSO approved firms, which includes graphite moulds, clamps, weld metal powders.

-

-

-

... More
Termination of the tail cable in the signal unit, wiring & testing of shunt signal.

-

-

-

... More
Supply of indication box to indicate 6 Quad & OFC communication.

2

33749

67498.84

... More
Supply of Plastocrate pre-fabricated OFC jointing pits size 1 x 1 x 0.6 meter as per technical specification. Technical Specification of Plastocrate pre-fabricated OFC jointing pits: The chamber of 1 mtr inner dia, 0.6 mtr height with 2 pieces cover on top with two hooks each and bottom cover with holes for drainage and cable entry as per drawing no. RAILTEL/ SR/ OFC/ 2009/ 12. The thickness of wall of pits should be min 50 mm. The chamber shall be filled with sand mixed with anti termite powder.

10

9929

99298.7

... More
Washers - 12 No.

-

-

-

... More
Execution of derivation joint of 6 quad cable for emergency socket box. all fixing material will be supply by the contractor as per the direction of site engineer.

6

3095

18575.64

... More
Carrying out circuit alterations in the existing/ New location boxes as per the new circuits which require excavation and releasing unwanted cables from the location box and taking new cables inside the location, clamping of new cables, filling the location box with standard up to the bottom of location and plastering.

1

1021

1021.53



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.