National Geophysical Research Institute Tender
For getting the details of etenders, if you are looking for information about them from the cumbersome government websites but are tired of doing so, Bidassist comes up with a one stop solution. It collates every Eproc telangana tender on Bidassist. One can approach it for the bidding process, registration process, etc., are explained below.
Costs
EMD
₹ 20,532Document Cost
₹ 590Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_CSIR_182849_1Bid Award Id
ViewTender No
NGRI-03/13/2023-WorksTender Authority
National Geophysical Research Institute ViewPurchaser Address
-Website
http://https://www.csir.res.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Renovation works, Painting works, Provision of Ladies Toilet in F.F. and provision of Shed in Rock Mechanics Building at CSIR-NGRI, Hyderabad.
BOQ Items
Providing and fixing Float glass panes withnecessary accessories 5 mm thick glass pane
2
-
-
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade including removing of old paint by sand papering : Two or more coats on old work
137
-
-
Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade. New work (Two or more coats applied @ 1.43 ltr/10 sqm. over and including base coat of cement primer)
239
-
-
Chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of Engineer-In-Charge. 25 mm average thickness
10
-
-
Providing, mixing and applying bonding coat of approved adhesive on chipped portion of RCC as per specifications and direction of Engineer-In-charge complete in all respect. Epoxy bonding adhesive having coverage 2.20 sqm/kg of approved make Fosroc or equivalent.
10
-
-
Repairs to plaster of thickness 12 mm to 25 mm or as per site requirment in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge. With cement mortar 1:4 (1cement: 4 coarse sand)
10
-
-
Removing door shutters from an existing door frame and removing fixed old lamination sheet by using a hot air gun or any mechanical method without damaging door shutters. Remove all old gum from the door shutter and repair the door shutter, firmly fixing all joints of door shutter.( Total area of door one side will be measured for payment.) including again fixing of door shutter in their old postion.
3
-
-
Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth all lead and lift upto 1.5 m, as directed by Engineer-in- Charge:
91
-
-
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:5:10 (1 cement : 5 coarse sand (zone-III) derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources)
7
-
-
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III)derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
5
-
-
Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge).
1.8
-
-
Providing and Fixing 15 mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per sqm including both side consisting of main ‘T’ runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross “T” of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main’T’ at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross ‘T’ of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting on periphery walls /partitions on a Perimeter wall angle pre coated steel of size(24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws @ 230 mm interval and laying 15 mm thick densified edges calicum silicate ceiling tiles of approved texture in the grid, including, cutting/ making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required. Main ‘T’ runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x0.8 mm, spaced at 1200 mm centre to centre along main ‘T’, bottom exposed with 24 mm of all Tsections shall be pre-painted with polyster baked paint, for all heights, as per specifications, drawings and as directed by Engineer-in-Charge.
Note :- Only calcium silicate false ceiling area will be measured from wall to wall. No deduction shall be made for exposed frames/opening (cut outs) having area less than 0.30 sqm.The calcium silicate ceiling tile shall have NRC value of 0.50 (Minimum), light reflection 85%, non- combustible as per B.S. 476 part IV, 100% humidity resistance and also having thermal conductivity 0.043 w/mK. (Note- The roof height is approximately 5.00 mtr and false ceiling height will be 3.00 mtr from floor.)
21
-
-
Providing and laying vitrified floor tiles(make of JOHNSON/ORIENT premium stain free or equivalent ) in sizes 600x600 mm (thickness to be specified by the manufacturer) with water absorptions less than 0.08% and conforming to IS :15622 of approved make , in all colours and shades, built in design tiles etc.including providing different coloured tiles of required size in designs as per instructions of Engineer in-charge including fixing with cement based high polymer modified quick set tile adhesive (water based) conforming to IS 15477 in average 6 mm thickness including grouting the joints with white cement and matching pigments etc complete.
70
-
-
Removing of Existing damaged / worn out PVC tiles flooring from floor and keep the PVC floor as per instruction of Engineer-in-chrage.
28
-
-
Providing and fixing anodised aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular and other sections of approved make conforming to IS:733 and IS: 1285 anodised transparent or dyed to required shade according to IS:1868.(Minimum anodic coating of grade AC 15), fixed with rawl plugs and screws or with fixing clips, or with expansion hold fastners including necesssary filling up of gaps at junctions, at top, bottom and sides with required PVC/neoprene felt etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/panelling, C.P. brass/stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing and panelling to be paid for separately.)For fixed portion Powder coated aluminium (minimum thickness of powder coating 50 micron)
23
-
-
Providing and fixing anodised aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular and other sections of approved make conforming to IS:733 and IS: 1285 anodised transparent or dyed to required shade according to IS:1868.(Minimum anodic coating of grade AC 15), fixed with rawl plugs and screws or with fixing clips, or with expansion hold fastners including necesssary filling up of gaps at junctions, at top, bottom and sides with required PVC/neoprene felt etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/panelling, C.P. brass/stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing and panelling to be paid for separately.) For shutters of doors, windows and ventilators including providing and fixing hinges/pivots and making provision for fixing of fittings wherever required including the cost of PVC/neoprene gasket required, rolling wheel, SS hings, push handle etc. Powder coated aluminium (minimum thickness of powder coating 50 micron)
14
-
-
Providing and fixing 12 mm thick prelaminated cement particle board Grade I, Type II conforming to IS:12823 bonded with phenol formaldehyde synthetic resin, of approved brand and manufacture in panelling fixed in aluminium doors, windows shutters and partition frames with C.P. brass/stainless steel screws etc. complete as per architectural drawings and directions of Engineer-in-charge. Prelaminated cement particle board with decorative lamination on both sides.
3
-
-
Providing and fixing IS: 3564 marked (make of Godrej) aluminium extruded section body tubular type universal hydraulic door closer with double speed adjustment with necessary accessories (having brand logo with ISI IS3564 embossed on the body , door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm ) and screws etc. complete
1
-
-
Providing and fixing bright finished 100mm mortice lock with 6 levers without pair of handles for aluminimum door with necessary scrrews etc complete(Best make of approved quality as Godrej, Sheel etc)as per direction of Engineer -in-charge.
1
-
-
Providing and fixing S.S. tubular handle bar 32mm outer dia, 3.0mm thick &300 mm long SS screwes etc. complete as per directions of Engineer-in-charge. S.S. tubular handle bar.
2
-
-
Providing and fixing aluminium hanging floor door stopper ISI marked anodised (anodic coating not less than grade AC 10 as per IS:1868) transpa- rent or dyed to required colour and shade with necessary screws etc as required. Twin rubber stopper
1
-
-
Providing and fixing aluminium tower bolts ISI marked anodised(anodic coating not less than grade AC 10 as per IS:1868) transparent or dyed to required colour or shade with necessary screws etc. complete 300 x 10 mm
2
-
-
Steel work in built up tubular/Pipes circular, rectangular,square etc. trusses including cutting, hoisting fixing in position including base plates, M.S plates etc. and applying a priming coat of approved steel primer, welded and bolted including special shaped washers etc. complete: Hot finished welded type tubes (make of TATA or Jindal)
359
-
-
Structural steel work welded in built up sections, trusses and framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete:
98
-
-
Providing and fixing of CRS sheet (make of JSW Galvalume or equivalent) of standard IS 513 having yield strength of 240 MPC with gavalanized as per IS 277/GIS 3302 of sheet 0.63 TCT zinc coating of 275 GSM both side mass painted as per IS 14246 RMP tolerance of 0.03 as per IS 513 of colour off white, green, light blue of wide 1.06 m semi corrogated sheets in curves as plans with Galvanized Hex Head Self Tapping Screw with bitumen washer and of required size and complete the job as per instruction of Engineer-in-charge. 0.50 mm thick with zinc coating not less than 275 gm/ m²
30
-
-
Providing and applying two coat Tapcrete with gry cement (1:2) as per manufacture specifications. (Total treated area shall be measured for payment.)
72
-
-
Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers:( Conplast X421 IC , Fosroc)
2
-
-
Grading roof/floor for water proofing treatement with Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 12.5 mm nominal size)
0.18
-
-
Grading roof/floor for water proofing treatement with Cement mortar 1:4 (1 cement : 4 coarse sand) with neat cement punning
0.1
-
-
Labour charges for filling of available coal rock surkhi in floors at all levels including watering, ramming etc to complete the job. Including labour charges for shifting of available coal rock in the campus all leads and lift.
1
-
-
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Glazed Vitrified tiles Matt/Antiskid finish of size Size of Tile 600 x 600 mm (make of RAK, Nito or equivalent as approved Engineer-in-chrage.
4
-
-
Providing and laying Vitrified wall tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mm (make of RAK, Nito or equivalent as approved Engineer-in-chrage.
10
-
-
Providing and fixing white One piece toilet Bowl (P Trap) water closet with tank with tankrim(4.8L/3L) (European type W.C. pan) with soft close seat and cover and flush fittings fixture complete including cutting and making good the walls and floors wherever required: ( Make of cera -Cattler or equivalent)
1
-
-
Providing and fixing wash basin (over counter) if required use C.I./M.S brackets or wash basin anchor bolt 15 mm C.P. brass pillar taps, 32mm C.P. brass waste of standard pattern,including painting of fittings and brackets, cutting and making good the walls wherever required: White vitreous China Wash basin size 410 to 450 x 315 to410 x150 to 195mm with suitable of 15 mm C.P. brass pillar sensor taps/lavatory faucet. (make of cear -Crespo or equivalent)
1
-
-
Providing and fixing PP flexible waste connection pipe for sink, wash basin or urinals including waste fittings complete. Flexible pipe 32 mm dia
1
-
-
Providing and fixing on wall/column face /under floor SWR pipe conforming to IS:4985 including jointing with seal ring conforming to IS:5382 including concrete bed or seddel of concrete mix 1:3:6 . use of Single or Double socketed pipes 75 mm diameter
10
-
-
Providing and fixing on wall/column face /under floor SWR pipe conforming to IS:4985 including jointing with seal ring conforming to IS:5382 including concrete bed or seddel of concrete mix 1:3:6 . use of Single or Double socketed pipes 110 mm diameter
10
-
-
Providing and fixing on wall/column/under floor face unplasticised-SWR moulded fittings/accessories for unplasticised-SWR pipes conforming to IS:4985 including jointing with seal ring conforming to IS:5382 leaving 10 mm gap for thermal expansion. Coupler 75 mm
2
-
-
Providing and fixing on wall/column/under floor face unplasticised-SWR moulded fittings/accessories for unplasticised-SWR pipes conforming to IS:4985 including jointing with seal ring conforming to IS:5382 leaving 10 mm gap for thermal expansion. Coupler 110 mm
2
-
-
Providing and fixing on wall/column/under floor face unplasticised-SWR moulded fittings/accessories for unplasticised-SWR pipes conforming to IS:4985 including jointing with seal ring conforming to IS:5382 leaving 10 mm gap for thermal expansion. Single tee with door 75x75x75 mm
1
-
-
Providing and fixing on wall/column/under floor face unplasticised-SWR moulded fittings/accessories for unplasticised-SWR pipes conforming to IS:4985 including jointing with seal ring conforming to IS:5382 leaving 10 mm gap for thermal expansion. Single tee with door 110x110x110 mm
1
-
-
Providing and fixing on wall/column/under floor face unplasticised-SWR moulded fittings/accessories for unplasticised-SWR pipes conforming to IS:4985 including jointing with seal ring conforming to IS:5382 leaving 10 mm gap for thermal expansion. Single tee without door 75x75x75mm
1
-
-
Providing and fixing on wall/column/under floor face unplasticised-SWR moulded fittings/accessories for unplasticised-SWR pipes conforming to IS:4985 including jointing with seal ring conforming to IS:5382 leaving 10 mm gap for thermal expansion. Single tee without door 110x110x110 mm
1
-
-
Providing and fixing on wall/column/under floor face unplasticised-SWR moulded fittings/accessories for unplasticised-SWR pipes conforming to IS:4985 including jointing with seal ring conforming to IS:5382 leaving 10 mm gap for thermal expansion. Bend 87.5 degree or required 75 mm bend
3
-
-
Providing and fixing on wall/column/under floor face unplasticised-SWR moulded fittings/accessories for unplasticised-SWR pipes conforming to IS:4985 including jointing with seal ring conforming to IS:5382 leaving 10 mm gap for thermal expansion. Bend 87.5 degree or required 110 mm bend
4
-
-
Providing and fixing UPVC nahini trap/floor trap including laying of cement concrete of 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of nominal size). 100mm x 75mm
2
-
-
Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : 20 to 40 mm nominal bore
2
-
-
Making connection of C.I. distribution branch with C.I. main of following sizes including cutting and jointing the pipe etc. complete : (fitting like Tee, lead joint will be paid separately) 75 to 150 mm dia
2
-
-
Cutting holes of required size in stone masonry wall of thickness 40 cm or more for passing the SWR pipes including filling the holes with 1:2:4 cement concrete and making good the same etc. complete as per direction of Engineer-in-charge. (Nos of passing pipes will be counted for payment, one passing pipe means one hole).
3
-
-
Providing and fixing 18mm thick gang saw cut mirror polished, premoulded and prepolished )machine cut for kitchen platforms, vanity counters ,window sills ,facias and similar locations of required size of approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand) with joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing etc., complete at all levels. Best quality fine texture Granite of any colour and shade ( Z Black, Telephone black or best colour equivalent) Area of slab over 0.50 sqm
1
-
-
Extra for providing edge moulding to 18mm thick marble stone counters, Vanities etc. including machine polishing to edge to high gloss finish etc.complete as per design approved by Engineer. Granite work. (Double or Single side)
2
-
-
Providing and fixing Chlorinated Polyvinyl chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain& brass threaded fittings including fixing the pipes with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the samd including testing of joints complete as per directions of Engineer-in- charge.( make of Ashirvad or Astral) Concealed work cutting chases and making good the wall etc. 15 mm dia. nominal outer dia. Pipes
10
-
-
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 20 mm nominal dia Pipes
15
-
-
Providing and fixing CPVC Union & brass threaded in CPVC pipe including cutting and threading the pipe and making long screws etc. complete (New work) 20 mm nominal bore
1
-
-
Providing and fixing C.P. Health faucet with 1.5 metre flexible stainless steel hose as approved. (make of Cera or Equivalent)
1
-
-
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 15 mm nominal bore
2
-
-
Providing and fixing uplasticised PVC connection pipe with brass unions : 45 cm length, 15 mm nominal bore
2
-
-
Providing and fixing 100 mm Stainless steel jali / floor drain jali with or without hole for waste pipe not less than 80 grams. (make of cera or equivalent)
2
-
-
Providing and fixing mirror of size 700 x 500 x 5 mm thick glass mirror with double coat for protection and longevity Grounded edges for safety and silver plating on the back for better reflection etc to complete the job. (make of cera Cat No. : B3510106 or equivalent as approved by the Engineer-in-charge.)
1
-
-
Half brick masonry with non modular fly ash bricks of class designation 10, conformingio IS :12894, in super structure above plinth and upto floor III level. Cement mortar 1 : 4 (1 cement : 4 coarse sand)
17
-
-
Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge. Made of G.I. wire of dia. 4 mm, PVC coated to achieve outer dia not less than 5 mm in required colour and shade.
16
-
-
15 mm cement plaster on the rough side of single or half brick wall of mix : 1:4 (1 cement: 4 fine sand)
31
-
-
Part B Electrical Work:- Supplying and fixing 12 Modular (200mm*150mm) GI box alongwith Modular base and covrer plate for Modular switches in recess etc. as required.
2
-
-
Supplying and fixing 8 Modular (125mm*125mm) GI box alongwith Moduler base and covrer plate for Modular switches in recess etc. as required.
15
-
-
Supplying and fixing 8 way double door, single pole and neutral, sheet steel, MCB distribution board 240V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (but without MCB/RCCB/Isolator)
2
-
-
Supplying and fixing 5A to 32A rating 240/415V, 10kA, 'C' curve miniature circuit breaker suitable for inductive load of Triple poles in the 32A MCB DB complete with connections, testing and commissioning etc, as required
2
-
-
Supplying and fixing 5A to 32A rating 240/415V, 10kA, 'C' curve miniature circuit breaker suitable for inductive load of single poles in the 16A MCB DB complete with connections, testing and commissioning etc, as required
10
-
-
Supplying and fixing cable end box (loose wire box) suitable for 8 way triple pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess complete with testing and commissioning etc as required
1
-
-
Supplying and fixing cable end box (loose wire box) suitable for 8 way triple pole and neutral, sheet steel vertical MCB distribution board, 415 volts, on surface/ recess complete with testing and commissioning etc as required
1
-
-
Supplying and fixing 5/6A moduler switch on the existing modular plate and switch box including connections but excluding moduler plate etc. as required
10
-
-
Supplying and fixing 5/6A moduler socket on the existing modular plate and switch box including connections but excluding moduler plate etc. as required
10
-
-
Supplying and fixing 15/16A moduler switch on the existing modular plate and switch box including commections but excluding moduler plate etc. as required
30
-
-
Supplying and fixing 15/16 moduler socket on the existing modular plate and switch box including connections but excluding moduler plate etc. as required
20
-
-
Laying of one number PVC insulated and PVC shethed / XLPE power cable of 1.1 KV grade of 50 sq mm 4 core size direct in ground including excavation, sand cushionong, protective covering and refilling the trench etc as required
70
-
-
Laying of one number PVC insulated and PVC shethed / XLPE power cable of 1.1 KV grade of 25 sq mm 4 core size direct in ground including excavation, sand cushionong, protective covering and refilling the trench etc as required
100
-
-
Wiring for 2' x 2' light point with 1.5 sq mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, with modular plate, suitable GI box, and earthing the point with 1.5 sq mm FRLS PVC insulated copper conductor single core cable etc. as required
8
-
-
Wiring for ceiling fan point with 1.5 sq mm FRLS PVC insulated copper conductor sing core cable in surface/ recessed steel conduit, with modular plate, suitable GI box, and earthing the point with 1.5 sq mm FRLS PVC insulated copper conductor single core cable, etc. as required
4
-
-
Wiring for pedestal fan heavy duty point with 1.5 sq mm FRLS PVC insulated copper conductor sing core cable in surface/ recessed steel condut, with modular plate, suitable GI box and earthing the point with 1.5 sq mm FRLS PVC insulated copper conductor single core cable etc. as required
4
-
-
wiring for fridge point circuit wiring alongwith earth wire with the 2*2.5 sq mm+ 1*2.5sq mm earth wire size of FRLS PVC insulated copper conductor, single core cable in surface/ recessed meadium class PVC conduit as required
1
-
-
Supply Installation, Testing & Commissioning of modular type Variable Refrigerant Flow/Variable Refrigerant Volume air cooled Outdoor units suitable for cooling and heating, having all hermetically sealed inverter type Scroll Compressor(s), minimum two compressors for above 14 HP modules, microprocessor based Controller, top discharge type condensing unit(s), with R 410 A Refrigerant, vibration isolators, with suitable foundation etc. complete as required. The unit shall deliver the rated capacity at AHRI Conditions and work even at 50°C ambient temperature without tripping. The unit shall be suitable to work on 400V +/- 10%, 3 Phase, 50Hz AC power supply. The unit shall be filled with first charge of the refrigerant and ready for use as required. The COP at AHRI conditions shall not be less than 3.1 and IEER not less than 6.5
5
-
-
Supply, installation, testing and commissioning of 2Tr capacity VRV/VRF High wall type Indoor unit equipped with washable synthetic media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, outer cabinet, cord less remote control, drain pan, necessary accessories etc., suitable for operation on 230 V ± 10%, 50 Hz, single phase AC supply, complete as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature.
2
-
-
Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of 6.4 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as required :
10
-
-
Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of 19 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm with 19 mm thick insulation nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as required :
10
-
-
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
8
-
-