For getting the details of etenders, if you are looking for information about them from the cumbersome government websites but are tired of doing so, Bidassist comes up with a one stop solution. It collates every Eproc telangana tender on Bidassist. One can approach it for the bidding process, registration process, etc., are explained below.
Indian Institute Of Technology - IIT Tender
Civil And Construction
Building Construction
Electrical and Electronics
Electrical Works
Eprocure
Opening Date3 Apr 2025
Closing Date15 Apr 2025
Tender Amount₹ 2,07,84,357
AI Insights
Technical
Technical
Financial
Class Of Bidder
... View More
Class I or Class II local Supplier.
Technical Capacity
... View More
The required prior work experience for the bidder involves satisfactorily completing similar works of a certain magnitude. The magnitude of similar works is specified as follows: - Three similar works each of value not less than 40% of the estimated cost
- Two similar works each of value not less than 60% of the estimated cost
- One similar work of value not less than 80% of the estimated cost (rounded to the nearest Rs. 10 lac) These similar works must have been completed in the last 7 years, ending on the last day of the month previous to the one in which the tenders are invited. The value of executed works shall be brought to current costing level by enhancing the actual value of work at a simple rate of 7% per annum, calculated from the date of completion to the last date of submission of tender.
Costs
EMD
₹ 4,15,700Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_IITH_855415_1Bid Award Id
ViewTender No
IITH/CMD/CIV/2025-26/NIT-01Tender Authority
Indian Institute Of Technology ViewPurchaser Address
-Website
http://eprocure.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Supply and fixing following modular base & cover plate on existing modular metal boxes etc.as require.
-
-
-
... More
Size of Tile 600 x 600 mm
4240
-
-
... More
Fly proof stainless steel grade 304 wire gauge with 0.5 mm dia. wire and 1.4 mm wide aperture with matching wood beading
22
-
-
... More
Providing and fixing chromium plated brass handles with necessary screws etc. complete:
-
-
-
... More
Size of Tile 600 x 600 mm
1215
-
-
... More
15 mm nominal bore
11
-
-
... More
Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1 :4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only. Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system, and rubber mallet for placing the tiles gently and easily, complete item of work including providng the granite strip threshold band of min thickness of 25 mm, and the width granite strip band shall not be less than 100 mm with moulding on both sides, fixing with rich cement mortar, with complete item of the works as per the directions of the Eng-incharge.
-
-
-
... More
2 X 4 sq. mm + 1 X 4 sq. mm earth wire
200
-
-
... More
Providing and fixing false ceiling at all heights including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x1 0x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wall screws@ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer -in Charge but excluding the cost of painting with :
-
-
-
... More
Design, fabrication, assembling, wiring, testing, supply, forwarding to site, unloading, shifting to location, inspection, installation, testing and commissioning of Floor standing LT Panel / Main distribution / sub-distribution panels fabricated out of 14 gauge CRCA sheet steel in cubicle formation, free standing floor mounted (IP65), dust and vermin proof. 16 gauge CRCA sheet steel shall be used for non load bearing walls, 2.5mm for load bearing member. 3 mm thick cable gland plates. 2 No. earthing terminals shall be provided for distrtibution panel. Lifting hooks shall also be provided for the panels.
Approval shall be taken for each panel in the form of shop drawings before fabrication.
-
-
-
... More
Glazed Vitrified tiles Matt/Antiskid finish of size
-
-
-
... More
20 mm dia
600
-
-
... More
Supplying and fixing single module Stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc.as required.
174
-
-
... More
Incomer:
I/C 1000A 4P EDO ACB 50KA, With Accessories(Coils)
Digital Metering with M/F Meter with RS 485 Port
ACB 50KA ON,OFF, TRIP, Spring Charge, In Service I/Lamps: 5 no's
40kA Surge Protection Device with control 32A Isolator 4P
Outgoing:
1. 125A 4P MCCB+Spders+Extn ROM 36 KA TM x 12no's.
MCCB Aux. Contacts, : 12 No's
MCCB ON, OFF, TRIP I/Lamps (Sets): 12 sets
Al. Busbars, Links, Supports, wiring etc.
MS PANEL OUT DOOR: Privision for spare feeders Metering: RYB Indication Lamps, Auto/Manual Selector Switch, ON/OFF Indication Lamps, ON/OFF Push Buttons. Only Approved makes should be used in the LT Panel / Main distribution / sub-distribution panel.
1
-
-
... More
Providing and fixing of Health faucet gun hand shower (Healthfaucet) modal no.(ALD-573) jaquar make with 8mm dia 1.20meter long flexible tube and wall hook including loading, transporting, unloading etc,complete as per the directions of the Engineer-in-charge.
10
-
-
... More
Taking out existing wooden door shutter, repair by cutting, painting etc.and refixing of repaired door shutters to existing door frames, including replacement of hinges with screws, etc. as required, all complete as per the direction of the Engineer-in-charge.
215
-
-
... More
One or more coats on old work
1415
-
-
... More
6 pin 15/16 A socket outlet
198
-
-
... More
Replacing of non functioning Flood lights with new 100W LED flood light including releasing of old light, installation of new flood light complete with all accessories, connection, testing, commissioning, shfting released material to store as directed by Engineer in charge etc. as required.
32
-
-
... More
12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) :2011 (Board with BIS certification marks)
3365
-
-
... More
Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick.
-
-
-
... More
Sub Head B: Electrical Works:
Wiring for circuit/ submain wiring along with earth wire with follwing sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required
-
-
-
... More
Supply of Surface/wall mounted 20W, 230V, LED batten type light fixture, 4 Feet, 6500k - Cool white, IP20, extruded thermal Polycarbonate housing provided for efficient heat dissipation with High optically efficient diffuser and integrated electronic driver with ISI mark as required.
Similar to Make : Wipro, Model: Garnet Batten-20W, 4ft, 6500k
368
-
-
... More
Providing and fixing aluminium tower bolts, ISi marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete :
-
-
-
... More
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :
-
-
-
... More
Disconnecting and removal of modular base & cover plate and switches & sockets and regulators from the existing switch board back box 8M/6M/3M and shifting to store from as directed by Engineer in charge.
552
-
-
... More
Supply and fixing of Digital Time Switch 240V AC 16A (NO) & 5A(NC) with ISI mark including connections, testing, commissioning etc. as required.Similar to Make : L&T, Model : Crono
8
-
-
... More
125mm
55
-
-
... More
Renewing glass panes, with putty and nails wherever necessary including racking out the old putty:
-
-
-
... More
Supply and fixing of aerocon panels of size (0.60mX 3.00m)and thickness of panel 50 mm, including loading, transporting, unloading etc,complete as per the directions of the Engineer-in-charge.
44
-
-
... More
5/6A Switch
1053
-
-
... More
15 mm nominal bore
22
-
-
... More
Dismantling of existing old Exhaust fans and installation of new BLDC exhaust fans of sweep 250mm complete with all accessories, connection, testing, commissioning,shfting released material to store as directed by Engineer in charge etc. as required.
180
-
-
... More
30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
20
-
-
... More
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
-
-
-
... More
Supply and fixing of 4 terminal FRP junction box 250 X 200 X 100 mm with din rail, to accommodate MCB, Digital Timer switch,Contactor etc. as required.
8
-
-
... More
Providing and fixing bright finished brass quadrant stay 300 mm long with necessary brass screws etc. complete
215
-
-
... More
Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1 :4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only, Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system, and rubber mallet for placing the tiles gently and easily. The existing wooden flush doors shall be removed completely before laying the virtified tiles and marking the levels inside the rooms, after laying the virtified tiles, the removed existing flush doors shall be re-fixed to the same rooms at the same position with complete item of works including cutting, fixing, wedging, jointing, and edging etc, inclusive of all accessories screws, hinges, etc., with complete item of the work, as per the directtions of the Engineering-incharge.
-
-
-
... More
Supply of Environmental friendly, long life, corrosion resistant, aluminum die cast housing, 100W LED IP 66 LED FloodLight Suitable for wall mounting etc. as required (Similar to Make: Wipro, Model: Alpha Flood light LF 20.
32
-
-
... More
Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content.
-
-
-
... More
Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour.
-
-
-
... More
Supply of Exhaust Fan BLDC (200mm) with ISI mark as required.
Similar to Make : Atomberg, Model : Efficio Exhaust Fan
180
-
-
... More
Disconnecting of all old cables from the old LT panel, incomer and all out going cables in panel( 2 no's LT Panels)
1
-
-
... More
Replacing of existing old ceiling fans with new BLDC ceiling fans of sweep 1200mm including dismatling of old fans, installation of new BLDC fan, connection, testing, commissioning, shfting released material to store as directed by Engineer in charge etc. as required.
288
-
-
... More
Replacing of existing old Fluorescent tube lights with new 20w LED batten lights including removing of old light, fixing of new LED batten, connection, testing, commissioning etc. as required.
368
-
-
... More
15/16 A switch
198
-
-
... More
Providing and fixing chromium plated brass curtain rod having wall thickness of 1.25 mm with two chromium plated brass brackets fixed with C.P. brass screws and PVC sleeves etc., wherever necessary complete :
-
-
-
... More
Supplying of following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
-
-
-
... More
Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.
-
-
-
... More
100x10 mm
80
-
-
... More
Single pole
8
-
-
... More
Supply of BLDC Ceiling Fans 28W, 1200 mm sweep with ISI mark as required, with regulator model.
(Similar to Make : Atomberg , Model : Efficio)
288
-
-
... More
3 Module
188
-
-
... More
Glazed vitrified floor tiles polished finish of size
-
-
-
... More
One Coat
12730
-
-
... More
With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre
1630
-
-
... More
Pinhead glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm)
625
-
-
... More
3 pin 5/6 A socket outlet
656
-
-
... More
2X1.5 Sq.mm+1X1.5Sqmm earth wire
130
-
-
... More
8 Module
333
-
-
... More
Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 :
-
-
-
... More
Providing and fixing to existing door frames.
-
-
-
... More
Providing and fixing 12.50mm thick tapered edge gypsum plain board confirming to IS:2095-(Part I): 2011 (BIS Certification) in true horizontal level / vertical level as per the site condition, the supporting framing structure shall be made of GI /MS with box framing as required at the site. The 12.50 mm thick tapared edge gypsum plain board IS:2095-(Part I): 2011 (BIS Certification) shall fixing over the framing structure with complete item of the work as per the design /drawing, including all part of the work to make it complete item, welding, fabrication etc, inclusive of all the necessary accessories like clamps, cleat angle, screws etc with complete item of the work, for all heights as per specifications, design, drawings and as directed by Engineer-in-charge.
295
-
-
... More
Sub Head A: Civil Works:
Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material with in 50 meters lead as directed by Engineer -in- charge.
3365
-
-
... More
Providing and fixing of over head shower 100mm model no (OHS-1661) jaquar make round shape single flow (face plate stainless steel &ABS body in chrome finish ) with Rubit cleaning system( including loading, transporting, unloading etc,complete as per the directions of the Engineer-in-charge.
10
-
-
... More
Supply and fixing of Contactor with front face handle 2 pole - 25A - 250V- 2 NO contacts with 230V coil - 1 module including connections, testing, commissioning etc. as required. Similar to make: Legrand, Catlogue No:412544
8
-
-
... More
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:
-
-
-
... More
Termination of LT cables in the new LT panel from size of 3.5C 240 sqmm -185 sqmm main Incomer cable and out going cables sizes of 90 sqmm - 25 sqmm cables. Which includes all required glands, lugs, mapower, etc. As per the directions of Ingineer-In-Charge.
1
-
-
... More
Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete
14
-
-
... More
Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1. 7 kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil.
70
-
-
... More
Handling, lifting and shifting of old panels safely from the shown location and shifting to safe location shown and placing the new panel in the location, includes all machinery and manpower,etc. As per the directions of Engineer-In-Charge.
1
-
-
... More
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
-
-
-