Hyderabad Metropolitan Water Supply And Sewerage Board Tender
... More
The HMWSSB has issued a formal invitation for competitive bids for the Hyderabad Metropolitan Water Supply And Sewerage Board project, for Replacement Of Old Damaged 100mm Dia Rcc/ac Water Supply Line With New 100mm Dia Di Water Supply Line At H.no.10-3-355 To H.no.10-3-331, Alsaba Vnc X Road To Avoid Low Water Pressure And Polluted Water Supply Complaints Under Vijaynagar Colony Section, Sd-ii, O And M Division-iii in Hyderabad, Telangana, with an estimated contract value of Rs. 2,61,358. The bid opening date for this tender is 23-05-2025 and the last date for bid submission is 30-05-2025. Interested bidders for Hyderabad Metropolitan Water Supply And Sewerage Board tender can download the important documents here to check the scope of work, eligibility criteria and technical requirements.
Costs
EMD
₹ 2,614Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
599018Tender No
43/CGM(E)/O&MC1/D3/2025-26, Dt.23.05.2025Tender Authority
Hyderabad Metropolitan Water Supply And Sewerage Board ViewPurchaser Address
-Website
http://https://www.hyderabadwater.gov.in/en/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
... More
Replacement of old damaged 100mm dia RCC/AC water supply line;Cutting of 150mm dia D.I. / C.I pipes without water in the main etc., complete as directed by the H.M.W.S.&.S. Board Engineers.
2
276
552.8
... More
Replacement of old damaged 100mm dia RCC/AC water supply line;Labour charges for lowering and keeping in position 100mm dia D.I / C.I. Sluice valves including conveyance of all materials etc., complete as directed by the H.M.W.S.&.S. Board Engineers.
2
255
510.6
... More
Replacement of old damaged 100mm dia RCC/AC water supply line;Jointing 100mm dia D.I. / C.I pipes and specials with S/S ends excluding the cost of joining materials such as lead or lead wool and hump yarn but including sundries such as cost of fuel for melting lead, filling with water and testing to required pressure etc., complete as directed by the H.M.W.S.&.S. Board Engineers.
2
280
560.8
... More
Replacement of old damaged 100mm dia RCC/AC water supply line;Jointing 150mm dia D.I. / C.I pipes and specials with S/S ends excluding the cost of joining materials such as lead or lead wool and hump yarn but including sundries such as cost of fuel for melting lead, filling with water and testing to required pressure etc., complete as directed by the H.M.W.S.&.S. Board Engineers.
2
349
699.4
... More
Replacement of old damaged 100mm dia RCC/AC water supply line;Jointing 100mm dia D.I. / C.I pipes and valves with D/F joints including cost of nuts, bolts, rubber insertion etc., including filling with water and testing to required pressure etc., complete as directed by the H.M.W.S.&.S. Board Engineers.
4
334
1337.2
... More
Replacement of old damaged 100mm dia RCC/AC water supply line;Jointing 150mm dia D.I. / C.I pipes and valves with D/F joints including cost of nuts, bolts, rubber insertion etc., including filling with water and testing to required pressure etc., complete as directed by the H.M.W.S.&.S. Board Engineers.
2
493
986.6
... More
Replacement of old damaged 100mm dia RCC/AC water supply line;Making dummy arrangements to existing 100mm dia WS mai at tail end point with socket tail piece and MS dummy plate, lead joints including including cost and conveyance of all materials including all other incidental and operation charges etc., complete as directed by the HMWS&SB Engineer.
1
3585
3585.36
... More
Replacement of old damaged 100mm dia RCC/AC water supply line;Cutting of open BT road surface including labour charges, all leads and other incidental and operational charges tool and plants etc complete for pipe line trenches as directed by the HMWS&SB Engineers.
11.25
1412
15894.56
... More
Replacement of old damaged 100mm dia RCC/AC water supply line;Labour charges for lowering and keeping in position 150mm dia D.I / C.I. Sluice valves including conveyance of all materials etc., complete as directed by the H.M.W.S.&.S. Board Engineers.
1
432
432.7
... More
Replacement of old damaged 100mm dia RCC/AC water supply line;Jointing 100mm dia D.I. / C.I pipes with plain spigot and modified socket rubber gasket (tyton) joints including all sundries but excluding cost of rubber gaskets etc., complete as directed by the H.M.W.S.&.S. Board Engineers.
25
178
4460
... More
Replacement of old damaged 100mm dia RCC/AC water supply line;Lowering the 100mm dia D.I. / C.I (K7) S/S pipes and specials carefully into the ready made trenches and laying them true to alignment and gradient including all labour charges, all operational charges etc., but excluding conveyance of pipes from Board stores to work site etc., complete as directed by the H.M.W.S.&.S. Board Engineers.
120
64
7752
... More
Replacement of old damaged 100mm dia RCC/AC water supply line;Earthwork excavation and depositing on the bank in all types of soils like black cotton soil, red earth, and ordinary gravel, hard gravelly soils, mixture of gravel, stoney earth and earth mixed with fair size boulders except rock requiring blasting with different lifts as per specifications and drawings and as directed by the departmental officers, including protecting the walls and other structures , existing water supply lines, sewers, power cables, telephone cables/ducts, storm water drains, traffic signals etc., wherever it is possible so as not to distrub the existing utility services etc., taking all precautionary measures in the restricted areas such as urban areas including diversion of the traffic,removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and including backfilling for pipeline trenches for laying Water supply/sewer lines including all incidental and operational charges etc., complete as directed by the HMWS&SB Engineers.. (For pipeline trenches).
76.8
497
38231.04
... More
Replacement of old damaged 100mm dia RCC/AC water supply line;Carting away the surplus excavated materials such as rock / earth from the site to a suitable distance of about 8 Kms including loading, unloading, conveyance charges and dumping the carted material at the contractors cost labour charges, all leads and lifts, all other incidential and operational charges etc., complete. as directed by the H.M.W.S.&. S. Board Engineers.
24.14
186
4512.73
... More
Replacement of old damaged 100mm dia RCC/AC water supply line;Redoing 15mm dia domestic water supply connection including eath work excavation cost of pipes with (MDPE) refilling etc., complete as directed by the H.M.W.S.&.S. Board Engineers.
90
254
22896
... More
Replacement of old damaged 100mm dia RCC/AC water supply line;Cutting of open CC road surface including labour charges, all leads and other incidental and operational charges tool and plants etc complete for pipe line trenches as directed by the HMWS&SB Engineers.
22.08
2939
64910.78
... More
Replacement of old damaged 100mm dia RCC/AC water supply line;Redoing of 100mm domestic sewer line connection including EWE in all available soils and including supply delivery of following dia SWG pipes and including lowering laying and jointing in CM(1:5:1) prop. Etc., complete upto 3' depth abd refilling with water and tampering etc.,Complete as directed by the HMWS&SB Engineers.
45
298
13410
... More
Replacement of old damaged 100mm dia RCC/AC water supply line;Supply and delivery fixing of RCC Precast manhole chambers having the size of 36"x21" dia at top fixing in CC 1:4:8 Prop:along with FRC Cover and frame laying CC 1:2:4 prop: including cost of materials labour charges earth work curing conveyance etc., Complete as directed by the HMWS&SB Engineers
3
6752
20257.2
... More
Replacement of old damaged 100mm dia RCC/AC water supply line;Cutting of 100mm dia D.I. / C.I pipes without water in the main etc., complete as directed by the H.M.W.S.&.S. Board Engineers.
2
147
294.8