Tidel Park Limited Tender

Search from a plethora of business opportunities for Tamil Nadu tenders posted on the eProcurement TamilNadu website and other online and offline sources. Here, on BidAssist, you can find the best tender opportunities to boost your enterprise by finding work in Tamil Nadu government tenders, PSUs, Municipal Corporations and more. Read on to learn about the bidder registration process, DSC and more.

Tidel Park Limited Tender

Works
Civil And Construction
Eprocure
Opening Date4 Oct 2024
Closing Date6 Nov 2024
Tender AmountRefer Documents 
Notes
Download

Costs

Summary

Construction Of It Office Building Ground Floor Plus 6 Floors Plus Terrace Including Civil Construction Interior Finishing Works Mep Works And Other Allied Development Works At Tiruchirappalli

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Bored cast in situ piles Installation of vertical cast in situ bored piles of following dia using design mix of grade M 40 reinforced cement concrete (using hard broken stone graded chips of size 20mm and less) by setting the bored cast in situ pile equipment's with all accessories and tools at each of locations based on the sequence of operations as directed by the Engineer-in-charge, boring for the piles from ground level in all soils to the required depth below cut off level to carry a safe working load not less than specified using transit bore mud circulation method (using bentonite clay of required density) inclusive of pile driving accessories, temporary casing pipe, bentonite solution of 10% of concrete with required specific density, mobilisation, transferring, installation of pile driving accessories from one location to another, over flow of concrete as minimum 1m from the pile termination level removal of mud from site up to a distance of 5km as directed by the departmental officers, cement is OPC or Sulphur resistance as per design recommendation, the length of pile to be embedded in the pile cap but excluding cost of steel and fabrication of reinforcement grills etc., complete complying with relevant standard specifications and as directed by the departmental officers.

-

-

-

... More
900 mm dia pile

6900

-

-

... More
1000 mm dia pile

2600

-

-

... More
Conducting Routine vertical compression load test for bored cast in situ RCC piles of following dia by direct loading in accordance with IS 2911 (part IV) 1985 dismantling the same after testing, including finishing pile head and supplying and erection of all kentledge of suitable magnitude as specified, labour, excavation, back filling, kentledge arrangements like jack, pump, hose, calibrated pressure gauge, calibrated dial gauges, crane & labours compaction. The test load as per (pile capacity, Test load (2.5 times of pile capacity), Kentledge load (25% of test load as per IS2911 Part IV)) for First test Before conducting test valid calibration submitted to the Engineer in-charge etc., complete complying with relevant standard specifications and as directed by the Engineer-in-Charge.

-

-

-

... More
900mm dia pile

1

-

-

... More
900mm dia pile

4

-

-

... More
1000mm dia pile

1

-

-

... More
1000mm dia pile

1

-

-

... More
Conducting lateral load test for bored cast in situ RCC piles of following dia by direct loading in accordance with IS 2911 ( part IV) dismantling the same after testing, including finishing pile head and supplying and erection of all kentledge of suitable magnitude as specified, labour, excavation, back filling, kentledge arrangements like jack, pump, hose, calibrated pressure gauge, calibrated dial gauges, crane & labours compaction. Before conducting test valid calibration submitted to the Engineer in-charge etc., complete complying with relevant standard specifications and as directed by the Engineer-in-Charge.

-

-

-

... More
900mm dia pile for First test

1

-

-

... More
900mm dia pile for Routine test

4

-

-

... More
1000mm dia pile for First test

1

-

-

... More
1000mm dia pile for Routine test

1

-

-

... More
Conducting Pull out test for bored cast in situ RCC piles of following dia by direct loading in accordance with IS 2911 ( part IV) dismantling the same after testing, including finishing pile head and supplying and erection of all kentledge of suitable magnitude as specified, labour, excavation, back filling, kentledge arrangements like jack, pump, hose, calibrated pressure gauge, calibrated dial gauges, crane & labours compaction. Before conducting test valid calibration submitted to the Engineer in-charge etc., complete complying with relevant standard specifications and as directed by the Engineer-in-Charge.

-

-

-

... More
900mm dia pile for First test

1

-

-

... More
900mm dia pile for Routine test

4

-

-

... More
1000mm dia pile for First test

1

-

-

... More
1000mm dia pile for Routine test

1

-

-

... More
Chipping of RCC pile head of following dia pile to the required cut off level and clearing away the debris from site with an average lead of 5km, the cost including labour charges, hire charges for tools and plants, loading and unloading charges, transportation etc., complete complying with relevant standard specifications and as directed by the Engineer in-charge.

-

-

-

... More
900mm dia pile

800

-

-

... More
1000mm dia pile

400

-

-

... More
Earthwork excavation in all stiff clay, stiff black cotton, hard red earth, shales, murram, gravel, Stoney earth and earth mixed with small size boulders and to the required depth as may be directed except in hard rock requiring blasting inclusive of shoring strutting and baling out water wherever necessary, depositing the surplus earth in places shown by the PMC/ Employer, clearing and levelling the site with an initial lead of 10 meter with in the compound and lifts as specified hereunder etc., all complete in all respects complying with relevant standard specification (excluding refilling)

-

-

-

... More
a)0 to 2 m depth

12800

-

-

... More
b) 2 to 3m depth.

810

-

-

... More
c) 3 to 4m depth.

710

-

-

... More
d) 4 to 5m depth.

510

-

-

... More
e) 5 to 6 m depth

330

-

-

... More
f) 6 to 7m depth

330

-

-

... More
Earth work excavation for foundation in all soils and sub-soils to the required depth as may be directed except in hard rock requiring blasting but inclusive of shoring, strutting, and bailing out water wherever necessary and refilling the sides of foundation with excavated earth in 150mm thick layers well watered rammed and consolidated and depositing the surplus earth in places shown by the PMC/ Employer clearing and levelling the site with an initial lead of 10 metres and lift as specified here under etc. complete in all respects complying with relevant standard specifications (including refilling)

-

-

-

... More
a)0 to 2 m depth

24940

-

-

... More
b) 2 to 3 m depth

2088

-

-

... More
c) 3 to 4 m depth

464

-

-

... More
d) 4 to 5 m depth

229

-

-

... More
Supplying and filling in foundation and basement with Stone dust in layers of 150 mm thickness well watered rammed and consolidated complying with relevant standard specifications including cost of stone dust and as directed by the Engineer in charge.

6519

-

-

... More
Plain cement concrete 1:4:8 (One of cement, four of sand and eight of hard broken stone jelly) for foundation using 20mm gauge hard broken stone jelly inclusive of shoring, strutting, centering and bailing out water wherever necessary ramming, curing etc., complete in all respects complying with relevant standard specifications and as directed by the Departmental officers. (in all heights and all depths) To meet the LEED certification, required ingredients such as fly ash/GGBS to be added in required proportion to meet the strength requirements.

2089

-

-

... More
Refilling with approved excavated earth available at site and depositing the earth as shown by the PMC/Employer in layers of not more than 15 cm thick well rammed, watered and consolidated etc. complete complying with standard specification. This item shall include rate for all soil testing as specified in standard specification.

13240

-

-

... More
Removal of surplus earth available in the site, clearing the earth away 5 Km from the site including conveyance chargesloading, unloading,hire charges for lorry, diesel,charges and labour charges etc all complete and as directed by the departmental officers

14885

-

-

... More
Supply, Filling and levelling, interacting the conveyed earth within a average lead of 25 KM, including necessary excavation, loading in trucks properly with a safer manner and transporting to the required site and unloading at required location, cost of hill earth, spreading in layers of 200 mm thick, mechanical compaction, breaking of clots, removal of foreign materials, / lumps / unwanted vegetation the source of earth consider from gundur etc., watering, including necessary field tests to be carried out as per the direction of Engineer in charge.

115406

-

-

... More
Providing and laying in position, Standardised Concrete Mix M-40 Grade in accordance with IS:456-2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cementcontent of 440 kg/m3 and maximum water cement ratio of 0.40, including admixture (plasticiser / superplasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5.0 cu.m.) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 cu.m.) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m') 7670 kg. of crushed stone sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the PMC/Employer. The coarse and fine aggregates to be used should comply with the requirements of IS Standards and cement is OPC/SRC as per design. (No separate payment will be made by the Department for the excess usage of materials).

-

-

-

... More
Foundation and basement -1.5 to ground floor level

5500

-

-

... More
-1.50m depth and upto -4.5m depth below ground level

3000

-

-

... More
-4.50m depth and upto -9m depth below ground level

300

-

-

... More
Ground floor

3900

-

-

... More
1st Floor

4100

-

-

... More
2nd Floor

4000

-

-

... More
3rd Floor

3950

-

-

... More
4th floor

4100

-

-

... More
5th floor

3800

-

-

... More
6th floor

4200

-

-

... More
7th floor (terrace floor)

500

-

-

... More
8th floor

300

-

-

... More
Supplying and erecting centering for sides and soffits including necessary supports and strutting upto 3.29 M height for plane surfaces as detailed below in all floors with all cross bracings using Mild Steel sheets of size 90 x 60 cm and 10 BG stiffened with welded Mild Steel angle of size 25mm x 25mm x 3 mm for boarding laid over silver oak joists of size 10cm x 6.50 cm spaced at above 90 cm centre to centre and supported by casuarina props of 10cm to 13 cm dia spaced at not more than 75 cm centre to centre in all floor etc., complete complying with the standard specification and as directed by the departmental officers. (Payment for centering shall be given after the concrete is laid)

-

-

-

... More
a) For R.C.C. works in foundation and basement such as grid beam, plinth beam, raft beam, raft slab, column base, column footings, pile cap, and other similar nature of works etc all complete

15960

-

-

... More
b) For plane surfaces such as slab, Lintel, beam, vertical slab, side slabs of boxing, vertical drops, facia, vertical wall, waffle slab etc.

135939

-

-

... More
c) For RCC surface of Square column and in small quantities such as sunshades, parapet cum drops, window boxing in projections and other similar works.

25790

-

-

... More
d) For circular columns

300

-

-

... More
e) Centering for curved surfaces of all RCC items of work

590

-

-

... More
f) For double height roof (slab bottom 8.25m)

1300

-

-

... More
g) Three floor height roof (slab bottom 12.45m)

1300

-

-

... More
h) four floor height roof with waffle slab (slab bottom 16.65m)

2200

-

-

... More
i) Form work for sump Vertical walls

2000

-

-

... More
Providing additional Strutting to centering of R.C.C slab of all surfaces or any other form works required at site during execution of work for every additional 1 metre height or part there of but not less than 30 cm over the initial 3.30 mt height (above 3.1m). complete complying with the standard specification and as directed by the departmental officers. (Payment for centering shall be given after the concrete is laid only for horizontal plain surfaces)

68075

-

-

... More
Supplying, Fabricating and placing in position steel reinforcement grills using M.S. I R.T.S. rods of all sizes of reinforcement for all Reinforced cement: concrete works (for pedestal pillar concrete) including cost and conveyance of steel, binding wire, spacer bars, cover blocks, labour charges for unbending of rods, straightening, cutting, fabricating, tying, lifting, placing in position, overlapping to the required length, No separate payment made for wastage and all other incidental charges etc. complete complying with standard specifications and as directed by "the departmental" officers. (The steel rods must be Fe 500 or Fe 550 grade of approved brand with ISI marking and necessary test certificate to be produced before using it at site)

7127

-

-

... More
POST TENSIONING WORKS : Design and Execution, of post tensioning works, including, decoiling the strands, cutting to the required lengths, supplying laying of HT strands sheathing (GI corrugated ducts 0.3mm thick) jointing with couplers, and inserting the strands, profiling, fixing live end anchorages, including the supply of stressing anchorages, suitable for 5-5 & 5-4 tendons, grout vents, making dead end anchorages, including flowering the strands, fixing tendon support bars, supervising the fixing of anti-bursting reinforcement, stressing the cables, end trimming, grouting the cables, with cement slurry, mixed with admixtures , with required tools, plants, and machineries, and consumables etc. (shuttering, concreting & reinforcement steel, shall be paid under respective items) at all heights including all leads, lifts, coordination, with the post-tensioning agency, preparation of drawings, obtaining approval from the Employer / Architect etc. Rate to include providing water, power, cement and admixture for grouting, packing of sheathing and anchorages blockings, filling of recess pockets after stressing using grouts(cement slurry mixed with approved admixtures) including providing access to post tensioning at all heights including all leads, lifts, scaffolding etc., all complete and as approved and as directed by the Employer /Architect but excluding shuttering, concreting & reinforcement steel which shall be payable under respective items separately

180

-

-

... More
Flyash Brick work in Cement Mortar 1:5 (One of cement and five of M sand) using Flyash bricks of size 9”x4¼”x2¾” (23x11x7cm) for super structure in the following floors including labour for fixing the doors, windows and ventilator frames in position, fixing of hold fasts, scaffoldings, curing etc., complete in all respect complying with relevant standard specifications and drawings.

-

-

-

... More
Foundation and Basement

1106

-

-

... More
Flyash Brick work in Cement Mortar 1:6 (One of cement and six of M sand) using Flyash bricks of size 9”x4¼”x2¾” (23x11x7cm) for super structure in the following floors including labour for fixing the doors, windows and ventilator frames in position, fixing of hold fasts, scaffoldings, curing etc., complete in all respect complying with relevant standard specifications and drawings.

-

-

-

... More
Ground floor

1778

-

-

... More
1st Floor

1510

-

-

... More
2nd Floor

1370

-

-

... More
3rd Floor

1170

-

-

... More
4th floor

1170

-

-

... More
5th floor

1170

-

-

... More
6th floor

1170

-

-

... More
7th floor (Terrace floor)

480

-

-

... More
8th floor

45

-

-

... More
Brick partition wall in Cement Mortar 1:4 (One of cement and four of M-sand) 110mm thick for super structure in the following floors using Flyash bricks of size 9”x4¼”x2¾” (23x11x7cm) including labour for fixing the doors, windows and ventilator frames in position, fixing of hold fasts, scaffoldings, curing etc., complete in all respect complying with relevant standard specifications and drawings

-

-

-

... More
Ground floor

1615

-

-

... More
1st Floor

160

-

-

... More
2nd Floor

160

-

-

... More
3rd Floor

160

-

-

... More
4th Floor

160

-

-

... More
5th Floor

160

-

-

... More
6th Floor

160

-

-

... More
7th Floor (Terrace Floor)

420

-

-

... More
Brick work in Cement Mortar 1:6 (One of cement and six of M sand) using second class chamber burnt bricks of size 9" x 41/2" x 3" for super structure in the following floors including labour for fixing the doors, windows and ventilator frames in position, fixing of hold fasts, scaffoldings, curing etc., complete in all respect complying with relevant standard specifications and drawings.

-

-

-

... More
Ground floor

400

-

-

... More
1st Floor

380

-

-

... More
2nd Floor

380

-

-

... More
3rd Floor

380

-

-

... More
4th floor

380

-

-

... More
5th floor

380

-

-

... More
6th floor

380

-

-

... More
7th floor (Terrace floor)

250

-

-

... More
Providing and fixing A non-load bearing, 90 mm thick, metal framed partition and sound insulation of 37 decibel up to a height of maximum 3.10 meters with Hilux calcium silicate board Specification, the total height of the roof is 4.2m the remaining portion between roof/beam bottom to the partition supported with 50x50x2mm thick ms channel, the 90 mm thick partition comprising of a composite framework which includes a GI 48 mm stud of 1 mm thick and having two unequal flanges of 48 and 50 mm each placed at 610 mm centre to centre in GI 50 mm floor and ceiling channel with two equal flanges of 32 mm each fixed to floor and ceiling at 600 mm centre, with the help of nylon sleeves and wood screws. Two layer of 10 mm thick Hilux Calcium Silicate Boards on either sides then screw fixed to the studs and channels at 200 mm centres on both sides of the frame work, insulation with 25 long self-drilling & tapping screws having Phillips head, This include of Hilux CSB 10mm (2nos each side, 1mm Floor Channel, Ceiling Channel, Stud, Jointing Compound, Jointing Tape, Screws, Labour, the center core filled with noise reduction Additional Support for Switch Box etc., the height of the partition as per drawing, the rate inclusive of all material, labour charges, lifting charges in all floors, joint tape and putty, transportation charges etc., and as per standard specifications.

1850

-

-

... More
Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Louvered Ventilators of from the profile the size of outer frame 60mm x 58mm and shutter profile size of 60 x 78mm both profiles are reinforced with GI/1mm 125GSM and 100% corrosion free, the profile are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with all over the edges of frame and shutter. The corners and joints should be welded and cleaned. Radiations pin headed glass 4mm thick should be provided in the louvers. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The ventilator should be got approved from the the departmental officials before use for work

94

-

-

... More
UPVC Window Specification: Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Windows of casement type from the profile the size of outer frame 60mm x 58mm and shutter profile are reinforcement with GI/1mm 125GSM and 100% corrosion free, the profiles are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with over all the edges of frame and shutter the shutter will be provided with Espag multi power point locks and also it operates as handle. The corners and joints should be welded and cleaned. Radiations free pin headed, plain or brown colour glass 5mm thick should be provided to the shutter and it should not allow leakage of water even at most ranging storms and should have key lockable action, security protective hinges, strong locking systems and as per size for arresting noise and energy loss. The connecting mechanism between sash and outer frame that enables opening of the window. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames.(open / sliding) etc all complete as directed by the Engineer in-charge.

942

-

-

... More
Supplying and fixing mild steel grills for windows, ventilators verandah enclosure, ladder and gate as per the design approved including one coat of primer and labour for fixing in position etc. all complete complying with relevant standard specification and as directed by the departmental officials. (The design of grill should be got approved from the the departmental officials before use)

46080

-

-

... More
Supply and fixing in position Hot rolled structural steel Primary E350 and secondary Members E250 (as per drawing) / Sections at all levels and to any shape & profile consisting of MS joists, channels, hollow sections, angles, GI purlins, GI runners, insert plates, flats and sag rods with necessary sleeves, bolts and nuts, gratings, pipes, edge protection for walls and columns, M.S. base plate, chequered plate of required thickness for duct closing and shafts closing at all floors at all levels with necessary supports such as M.S. angles / M.S. flats, stiffeners to be placed on angle iron frame work including cutting, straightening, welding as per standards for connections including consumables, anchor fastener etc. complete. Rate including all materials, labour charges, scaffolding, staging, transportation, lead & Lifts, wastage, etc,. No separate payment made for bolts, anchor fastener, nuts, washers, welding etc., Rate shall including preparation of surface, all MS members shall be painted with anti corrosive paint, with two coats of 1st class synthetic enamel paint of complete, as directed by the Engineer-in-charge.

175200

-

-

... More
Painting new iron works such as steel doors, window grill, ventilators, window bars, Kerb stone, balustrades etc., with two coats of best approved first quality and colour of synthetic enamel paint over the existing red oxide priming coat in all Floors excluding cost of priming coat etc, all complete complying with standard specifications and as directed by "the departmental" officers. (The make, quality and colour of paint should be got approved by the the departmental officials before use on works.)

3597

-

-

... More
Plastering in C.M 1:3 (one of cement and three of M sand) 10 mm thick for bottom of sunshade, ceiling in all floors, including scaffolding, curing, finishing, etc., complete complying with standard specification and as directed by the departmental officers.

12600

-

-

... More
Plastering with cement mortar 1:5 (One of cement and five of M sand) 12 mm thick finished with neat cement including, 100% Virgin Polypropylene fibres for all brick and RCC joints, providing band cornice, ceiling cornice, inner, outer walls, scaffolding, curing etc., complete complying with standard specification and as directed by the departmental officers.

142920

-

-

... More
Providing and applying 18mm thick Cement Plaster in two coats under layer 12mm thick cement plaster 1:5 (1 cement : 5 coarse sand) and a top layer 6mm thick cement plaster 1:3 (1 cement : 3 coarse sand) finished rough with sponge. The cost to include with drip course/ groove as specified, 100% Virgin Polypropylene fibres for all brick and RCC joints, providing band cornice, ceiling cornice, inner, outer walls, scaffolding, curing etc., complete complying with standard specification and as directed by the departmental officers.

13020

-

-

... More
Plastering with cement mortar 1:3 (One of cement and three of M sand) 12 mm thick finished water proofing compound with neat cement including, 100% Virgin Polypropylene fibres for all brick and RCC joints, providing band cornice, ceiling cornice, inner, outer walls, scaffolding, curing etc., complete complying with standard specification and as directed by the departmental officers., complete complying with standard specification and as directed by the departmental officers.

10820

-

-

... More
Providing Polymer Coating (Water Proof Coating) for sunken portion of toilet with following specification and the surface shall be cleaned to remove all dust, foregin, matters lose materials or any other deposits of contamination by rubbing with wire brush. Slurry: Dry blend and polymer liquid blend shall be mixed into the desired ratio as per recommendation of the supplier. The mix shall be stirred thoroughly until no bubbles remain in the mix. Any lumps found in mix shall be removed. Apply first coat of polymer modified cementitious slurry by brush on wet cleaned surface. After drying, second coat shall be applied on the first coat as directed by the departmental officers etc. The rate inclusive of cost of materials and labour, etc., complete.

5300

-

-

... More
Plastering with cement mortar 1:5 (One cement and five M sand) 20 mm thick mixed with water proofing compound conforming to BIS at 2% by weight of cement used including finishing, curing, etc., complete complying with standard specification and as directed by the departmental officers.

2780

-

-

... More
Painting two coats of newly plastered Internal, external wall, false ceiling surface with plastic emulsion paint of first class quality and of approved colour over a priming coat including thorough scrapping, clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., complete complying with standard specification and as directed by the departmental officers.

182230

-

-

... More
Supplying and applying of Full putty two coats with approved make wall putty for smooth finishing the new cement plastered walls / false ceiling including cost of putty, brushes, watering curing labour charges for apply putty, blade, emery sheet in all size etc., complete as directed by the departmental officers.

159020

-

-

... More
Providing and laying of Dadooing walls with 300mm x 450mm x 10mm designed glazed tiles of approved make of tiles using Cement Mortar 1:2 (One Cement and Two M.sand) 10mm thick and pointing the joints with white cement mixed with colouring pigments at the rate of 0.40 Kg. / sq. m. neatly in all floors, curing, the tile edges finished with necessory PVC trims, spacer, no extra payment made for wastage of materilas, PVC trims all the waste materials are disposed from the site etc., complying with standard specification and as directed by the departmental officers.(basic cost of tile is 45Rs/Sqft)

5525

-

-

... More
Supplying and laying of Ceramic Tiles of minimum size of 305mm x 305mm x 6mm (Anti-skid) laid over 20 mm thick cement mortar 1:3 (One Cement and Three M.sand) base mortar over the existing slab / floor including cutting the tiles to the required size with special cutter wherever necessary, laying in position and pointing with white cement mixed with colouring pigment at the rate of 0.3 Kg. / sq. m. etc., complete complying with standard specification. (basic cost of tile is 40Rs/Sqft)

3306

-

-

... More
Supplying and laying the floor with best quality Nano polish Vitrified Tiles of size 600 x 600 x 8mm thick glossy finish or Mat finish of approved colour, shade and quality laid in cement mortar 1:3 (one cement and three M. Sand) 20mm thick in all floors and the top pointed with the white cement mixed same colour pigments, colour, shade, pattern and finishing of the tile is as per drawing the tile edges finished with necessary PVC trims, spacer. no excess payment made for wastage of materials, all the waste materials are disposed from the site etc., complete complying with standard specification. (The make and brand of the tiles should be got approved by Executive Engineer before use on works) (basic cost of tile is 65 Rs/Sqft)

21470

-

-

... More
Providing 40mm thick granolithic floor finish of the following thickness with plain cement concrete 1:2:4 (One Cement, Two M. Sand and Four aggregate) using 10 to 12mm gauge hard broken stone jelly including laying, finishing and the top rubbed smooth with power trawl, thread lining, curing etc. complete complying with standard specification and as directed by the departmental officers.

29400

-

-

... More
Newly Constructed Roof/Podium with 2K PU Waterproof coating above 2000 Sq.m Providing and Applying two component Polyurethane based cold applied seamless waterproofing coating to the RCC surface like Roof & Podium area applied @ 2.1kg/m2 in single coat using 3mm notched trowel to achieve 1.5mm DFT, including a prime coat of solvent free, medium viscous, epoxy primer @0.2L/m2 and protection with 120gsm Geo-textile over the 7 days cured waterproofing membrane. The Waterproofing material shall have Solids 98%, Tensile strength 6 Mpa, Elongation at break 600% as per ASTM D 412, crack bridging ability (no cracks up to 3.2mm) confirms to ASTM C 1305, Puncture resistance 300N as per ASTM E154, Shore A Hardness 70 as per ASTM D 2240, Adhesion to peel after water immersion as per ASTM C 794 at 5.2N. Resistance to root penetration. The finished cost to include surface preparation, making coving of 50 mm X 50mm at all right angles of wall Junction with Polymer Repair Mortar and lay 60gsm Geo-textile over the angle fillet when the first coat in still wet, treatment of cracks and laying 120GSM Geo-textile as seperation/protective layer over the fully cured PU coating completely as per specification.

11600

-

-

... More
Providing and fixing of 30mm thick Solid PVC Sliding Door shutter conforming to relevant IS standard of best approved quality & superior variety for easy access to physically challenged and differently abled persons including cost of door, rails, hardware materials, labour charges etc., complete and as directed by the departmental officers.

100

-

-

... More
Supply and installation of fire WPC solid door frame extruded with size 75mm x 50mm. The inner core made of rigid WPC compound with minimum shore hardness of 55, and Bulk Density 800 Grms/Cub. Mt. The frame shall be fixed onto the wall using 8 x 100mm long M.S fastener, Screw fitted with polymeric nylon sleeve. A required no's of screws to be provided for each vertical and horizontal member. The cost includes transportation, installation and with all necessary hardware arrangements etc., all complete as directed by the Engineer in-charge.

1261

-

-

... More
Supply & fixing of 25mm (+/- 1mm) thick WPC Decora Door which is extruded as a single core door with Lead-Free compound. The door is designed homogeneously by Smooth Routing and 3D embossed grains on one side. The other side of the door shutter shall be plain mat finish. The door must be completely made by machine, without any post-production fabrication. The Solid WPC board shall have minimum Bulk Density 650 KG/ Cub. Mt. The door is suggested to be hinged to the frame with minimum of 5 inch butt hinges of SS make. The cost includes transportation with tax, installation and all necessary hardware such as (Hinges, Tower bolt, Handle, Indicator lock, Screw, CNC lover). The frame of the doors, the orientation of the doors and the colour of the doors are as per the architectural drawings.

345

-

-

... More
Manufacturing, Supplying and Fixing of Stainless Steel Hand rails for staircase, Ramp using one or two nos of 50mm dia 304L Grade Stainless Steel pipe of 1.60mm thick with support at required locations to a height of 1200mm from finished floor level welded to 38mm dia Stainless Steel pipe (additional top vertical & intermediate for physically challenged where required) post of 1.00mm thick as vertical at 900mm centre with 2 Nos. of 25mm dia intermediate horizontal stainless steel pipe of 1.60mm thick in between. The vertical pipe has to be welded to the 100 X 100 X 6mm MS base plate encased in the base concrete. The rate is inclusive of the charges for cutting, bending, welding, grinding, polishing, conveyance, electrical charges, etc. complete

1060

-

-

... More
Manufacturing, Supplying and Fixing of Stainless Steel Hand rails for staircase near wet riser using 50mm dia 304L Grade Stainless Steel pipe of 1.60mm thick will be provided with tubular supports made of 304L Grade Stainless Steel pipe of 25mm dia of 1.60mm thick welded to the railing. The supports will be grouted into the wall and provided with 93.00mm thick Stainless Steel circular base plate of 304 Grade. The rate shall included for grouting into concrete with necessary supporting arrangements the hand rail in floor polishing buffing, bonding, cutting, grinding, conveyance, welding charges, electrical charges, etc. complete

785

-

-

... More
Finishing the top of Terrace floor with one course of solar reflective water proof, heat proof and cool roof ceramic tiles of size 300mmx240mmx6mm thick of approved quality laid in cement mortar 1:3 (one part of cement and three parts of sand) 20mm thick over base concrete including Base concrete of average thickness of 60mm using 1:2:4 (6-10mm thick metal) cutting the tiles to the required size with special cutter wherever necessary, laying in position and pointing with white cement at the rate of 0.3 Kg. / sq. m. the colour of tile got approval from departmental officers, no excess payment made for wastage of materials, all the waste materials are disposed from the site etc., complete complying with standard specification.

9000

-

-

... More
Supplying and fixing in position FRP (Fiber Reinforced Plastic 10MT) manhole covers with FRP frames of inner opening size 60cm x 60cm of best approved quality as per standard specification including cost of materials, labour charges for fixing and conveyance of material, lifting charges etc., complete complying with standard specifications

32

-

-

... More
Supplying and fixing of 12 mm thick double wall Poly carbonate day light sheet including fixing in position with aluminium strip and rubber work as per standard specification including, fixing of bolts / nuts and including cost of all materials like aluminium strip for joints, joint sealant, labour charges for fixing, etc., all complete including scaffolding wherever necessary and as directed by departmental officers.

1300

-

-

... More
Supplying and fixing of single leaf Solid core flush door shutters using boiled water resistance (BWR) teak wood ply as per IS 303-1989, the cross band and face veneers are to be banded with phenol formaldehyde synthetic resin in hot press both sides and manufacturing the shutter by using quality timber of termite proof and seasoned to moisture content not more than 10%, hot pressed with hydraulic press at a temperature of 150o to the norms as per IS 2002-1983 and TW Ply on Both side with teak wood lipping around, 35mm thick including cost and fixing of Brass furniture fittings such as 5 no's 125x30mm hinges, 1 No of brass Tower bolt 400mm long and 12mm dia, 2 Nos 200mm ornamental brass Handle, Mortice Lock with required screws with 3 Keys With Night latch, 1No 40mm dia & 60mm long rubber bush, 1 no Door stopper with rubber bush, Hydraulic Door Closer (heavy duty) with required Brass screws, labour charges for wrought and put-up and fixing in position of flush shutters and as directed by the departmental officers.

-

-

-

... More
a) Flush door shutter size 1200x2400 (Single leaf)

10

-

-

... More
b) Flush door shutter size 1000x2400 (Single leaf)

30

-

-

... More
c) Flush door shutter size 900x2400 (Single leaf)

35

-

-

... More
Supplying and fixing of Teak Wood wrought and put up for frames of doors, windows, ventilators, cupboard and any other similar joinery works with necessary plugs, rebates for shutters, plaster grooves on all faces etc., including labour charges for fixing hold fasts, complying with relevant standard specifications etc., in all respects.

-

-

-

... More
a) 2 to 3m length

8.45

-

-

... More
b) 0 to 2m length

3.1

-

-

... More
Supplying and fixing of best Ornamental Indian Teak wood panelled door of Double leaves shutters in position using 2 x 2 Nos of 100mmx37.5mm styles and 2x3 Nos. of 150x37.5mm rails (Top, Bottom and Lock rail) and 18.75mm thick planks for panels including cost of all materials and labour for ornamental carving and fixing the Brass furniture fittings such as 10 Nos of 125x30mm brass Butt hinges, 1 No of 400mm brass Tower bolt, 2 Nos of 300mm brass Tower bolt, 4 Nos of 450mm majestic door handle, with 5mm thick vision panel as per drawing and mortice lock with brass handle, 2nos of Hydraulic Door Closer (heavy duty) etc., all complete and as directed by the departmental officers. Door size 1.80m x 2.40m

30

-

-

... More
Providing wooden (Melamine Door) Polish for new wood by removing by blade scrapping the existing dirt from the wooden surface sand paper with M50 and repeat M80 paper to get a smooth surface leaves at least 4hrs drying sand paper and prepare surface by M100 and clear the surface apply one coat of touch wood stainer by brush and leaves for two hrs. for drying prepare the surface by M100 sand paper and apply one coat of ash sanding sealer mixed with approved quality thinner after drying apply one coat of sanding sealer and attend the surface to get thoroughly dried smoother surface with no.220 water emery wood cleaner fill the holes and dots by putty and packing to get the surface clean apply surface by wax emery no.220 apply first coat of melamine sealer with the thinner for preparing the surface and apply second coat of the same by dry aftering drying preparing the surface with water emery no.330 and apply two coats of melamine matt mixed with glazing and thinner 106 prepare the surface water no.320 and apply two coats of same and finally smoother etc., all complete including cost of all materials and labour etc., and as directed by the departmental officers

70

-

-

... More
Painting new wood work with two finishing coats of synthetic enamel ready mixed paint of approved quality and colour over one coat priming coat with necessary putty in all floors including the cost of primer, synthetic enamel ready mixed paint, cotton waste, brush, labour charges etc., complete complying with standard specification the colour and shade got approval from departmental officers and as directed by Engineer in-charge.

480

-

-

... More
Supplying and fixing of approved colour and quality granite for flooring, Kitchen top/top of wall/ steps not less than 18mm thick over cement plastering in CM 1:3 (One of Cement and three of sand) 20 mm tk cost including laying in position cutting the slab to the required size wherever necessary dobule/single nosing, grove making, pointing the joints with coloured cement, curing, cutting the shapes where ever required, in all floors etc all the waste materials are disposed from the site the colour of the granite is Ruby red / Raw silk / Jet Black / Synthetic Grey / Paradise colour. all complete and as directed by the departmental officers (The minimum cost of granite as Rs.170/Sqft)

7110

-

-

... More
Supplying and fixing of Granite Superfine polished with machine cut edges 18 to 20mm thick for wall cladding over cement plastering in CM 1:2 (One of cement and two of sand) 10 mm thick including fixing in position, grove making, nosing, clamps with lockset arrangements, cutting the tiles to the required size wherever necessary, pointing the joints with Grout (Tile joint filler), curing, finishing, in all floors etc., the colour of the granite is Ruby red / Raw silk / Jet Black / Synthetic Grey / Paradise colour etc., all the waste materials are disposed from the site etc., all complete and as directed by the Engineer in charge. (The minimum cost of granite as Rs.170/Sqft)

3200

-

-

... More
Supplying and fixing of Flamed Steel Grey Granite Slab of 18mm Thick slab of approved quality for flooring not less than 18mm thick over cement plastering in CM 1:3 (One of Cement and three of sand) 20 mm tk cost including laying in position cutting the slab to the required size wherever necessary dobule/single nosing, grove making, pointing the joints with coloured cement, curing, cutting the shapes where ever required, in all floors etc all the waste materials are disposed from the site., all complete and as directed by the departmental officers (The minimum cost of granite as Rs.180/Sqft)

3110

-

-

... More
Designing, Supply, Fabrication & fixing structural Glazed fully unitized system to the RC/steel/block works either straight, segmented or skylight as per the drawing consisting of main panel work of vertical & horizontal aluminium sections of 131 x 67 x 3 mm thick; The outer profile shall be of 131 x 38 x 3 mm thick. The glazing panels will be of 67 x 27.5 x 2 mm made from specially designed extruded powder coated aluminium profiles. All the profiles shall be provided with protective tapes. All the bolts nuts and washers used shall be of Galvanized steel, The screws shall be of G.I make, brackets shall be of G.I make as per site requirement EPDM gaskets of suitable profiles shall be provided at all required positions to make the glazing airtight. The glazing shutter panels after being fabricated shall be cleaned for removing any dust and two-sided structural Adhesion tape shall be applied and the glass duly surface cleaned shall be stuck to the glazing panel. Subsequently external grade structural silicone from dow795/v- tech/ meriseal/ joinleader to be used for glazing. The rate inclusive of necessary openable windows in the glazing system. The glazing panel shall be given adequate time for curing in horizontal position. The fixing of the glazed panel to the mullion and transom framework shall be done by inserting the shutter fixing cleat in the shutter profile and fixed with 8 mm x 38 mm screws.

10000

-

-

... More
The grooves between the glazed shutters shall be sealed by inserting bond breaking backer rod and by application of high-performance weather silicone sealant from dow/v-tech/meriseal/joinleader/boss to be used. Heat strengthened glass: 27.52 mm Insulated High Performance glass unit comprising of DGU/SGU glass or equivalent 6 mm tempered + 1.52 PVB laminated + 12 Air gap + 8 mm Tempered. The heat strengthened spandrel glass/ Colour glass consist of U-value ≤ 3.8 W/Sq.mK, Solar factor ≤ 0.23, Shading co-efficient ≤ 0.27. The size of the glass, shape, shade as per the architecture drawing and as per standards. The glass must be griha rated.

-

-

-

... More
Designing, Supply, Fabrication & fixing structural Glazed fully unitized system to the RC/steel/block works either straight, segmented or skylight as per the drawing consisting of main panel work of vertical & horizontal aluminium sections of 131 x 67 x 3 mm thick; The outer profile shall be of 131 x 38 x 3 mm thick. The glazing panels will be of 67 x 27.5 x 2 mm made from specially designed extruded powder coated aluminium profiles. All the profiles shall be provided with protective tapes. All the bolts nuts and washers used shall be of Galvanized steel, The screws shall be of G.I make, brackets shall be of G.I make as per site requirement EPDM gaskets of suitable profiles shall be provided at all required positions to make the glazing airtight. The glazing shutter panels after being fabricated shall be cleaned for removing any dust and two-sided structural Adhesion tape shall be applied and the glass duly surface cleaned shall be stuck to the glazing panel. Subsequently structural external grade silicone from dow 795/v- tech/meriseal/ joinleader to be used for glazing. The glazing panel shall be given adequate time for curing in horizontal position.

3400

-

-

... More
The fixing of the glazed panel to the mullion and transom framework shall be done by inserting the shutter fixing cleat in the shutter profile and fixed with 8 mm x 38 mm screws. The structural glazing is suitable for vertical and horizontal members like portico for portico MS suspended supports pay separately. The grooves between the glazed shutters shall be sealed by inserting bond breaking backer rod and by application of high-performance weather silicone sealant from dow/v-tech/meriseal/joinleader/boss to be used. Heat strengthened glass: 8 mm Insulated High Performance glass unit comprising with noise reduction insulation and of DGU/ SGU glass or equivalent 8 mm tempered. The heat strengthened spandrel glass/ Colour glass consist of U-value ≤ 3.8 W/Sq.mK, Solar factor ≤ 0.23, Shading co-efficient ≤ 0.27. The size of the glass, shape, shade as per the architecture drawing and as per standards. The glass must be griha rated.

-

-

-

... More
MS Tonnage (Considered 15kg/sqm of stick glazing area) : Suspended supports for portico the stick glazing as well as the Unitized Glazing Design, Fabrication, Supply and install required structural steel frame work in line made out of MS pipe sections / I Beams / Channels / Plates / built up sections of approved make make of first quality confirming to IS standard. The steel design shall accommodate thermal stresses resulting from thermal expansion due to surface temperatures. The steel structure shall be finish with the following, i. Surface Preparation – Blast cleaned to Sa 2.5 confirming to BS EN ISO 8501-1 ii. Primer : Zinc Rich Epoxy 75 micron iii. Barrier : Epoxy Mio 125 micron iv. Finish : Polyurethane – 50 Micron (Only for exposed steel)

16000

-

-

... More
Aluminium Composite Panel: Fabrication, supply and fixing of Fire Resistance grade Aluminium Composite Panel of 4 mm thick composed of Magnesium hydroxide filled core sand witched between two skins of each 0.5mm thick aluminium sheet. The grade of Aluminium of AISI 3105/5005 H14. The surface coating should be of PVDF coating. The fire resistance panel should pass the following tests. The test for construction products EN/350/-1:2007 and the fire behaviour should pass A2 standards. The fire propagation fire spread BS 476 part 6 and should pass class "O". Fire resistance USANFPA 285 should pass class A. The fire resistance ACP should pass 2 hrs fire rating with standards ASTME119. The system shall be fixed using 50 x 25 x 3 mm thick, GI the brackets and good quality bolt and all other necessary spring washers and cap nuts, add MS angle or hollow tube as supports from wall to framework as per drawing, pressure lockset work for required locations and all other necessary accessories sealing shall be done using weather sealant of Dow corning 789 make or approved equivalent make the rate inclusive of necessery CNC cutting as per design. The shade and colour of ACP as per architectural drawing, The aluminium section/brackets and ACP should withstand the design wind pressure of 200kg m/sq and all work complete.

9000

-

-

... More
Providing and fixing sensor operated main entrance fully glazed frameless doors with suspended spider glazing façade of approved make point façade, glass bracket-5 no’s PPF G2 point façade wall bracket -2 no’s PPFGT-1 point bracket -12 no’s B2 G.S bracket -5 no’s FHB M2 -Flat head fixed bolt-36 nos. Anchor fasteners HILTI -48 no’s Aluminium U Channel -3 nos. ES 200 easy-operator profile 6250 mm (double leaf door open width - 3.00m & height 2.4m) mechanical components, electrical components on glass mounted with magnet 1 no’s with 12 mm toughened glass & 8+1.52+8 mm toughened + laminated glass for fin.

4

-

-

... More
Providing and fixing sensor controlled sliding door with all tracks, rail, control unit, sliding door leaves, top light or solid panel, safety light barrier, activator or radar motion detectors all fixtures and glass complete . Dimensions will be as per drawing. Height will be measured from the top rail to the floor & width till the end point of the sliding shutter in open condition frosting by stickers are also included in the item. The rate inclusive of all hardware items for fixing and holding the glass, sealant for gaps, patch fittings etc., all complete as directed by the departmental officers

-

-

-

... More
Providing and fixing of fixed glass railing with 12mm thick frosted/plain toughened glass as per architectural drawing with necessary aluminium / stainless steel 304 grade frame, with patch fixtures (ULPT 90, ULPT 92) SS B1 brackets to support the glass on top including sealant the size and shapes of glass, SS frames and balls in hand rail as per drawing etc complete as per specifications and as directed by the Engineer in charge.

700

-

-

... More
Providing and fixing of fixed glass Partition/Roof top with 12mm thick clear toughened glass with patch fixtures (ULPT 90, ULPT 92) SS B1 brackets to support the glass on top from roof including sealant the cost including trasportation, lifting charges, fixing charges etc complete as per Manufacturer’s specifications and as directed by the Engineer in charge.

5720

-

-

... More
Supplying and fixing of 12mm thick toughened frosted/plain glass with top patch, bottom patch, corner lock and SS H type handle 500mm long with required screws, Double Acton Hydraulic Floor Spring and imported SS finish in Single leaf door including labour charges and other fitting, door beading with standard specification, door for all size and floors etc all complete and as directed by the departmental officers.

40

-

-

... More
Supplying and fixing of 12mm thick toughened frosted/plain glass with top patch, bottom patch, corner lock and SS H type handle 500mm long with required screws, Double Acton Hydraulic Floor Spring and imported SS finish in double leaf door including labour charges and other fitting, door beading with standard specification, door for all size and floors etc all complete and as directed by the departmental officers.

520

-

-

... More
Supplying and fixing in position of 10 mm thick Hilux board false ceiling using GI perimeter channel of size 0.55 mm thick (having one flange of 20 mm and another flange of 30 mm and web of 27 mm thick) along with perimeter of ceiling screws fixed with brick wall/ partition/ RCC work with help of nylon sleeves and screws @ 600 mm center to center, then suspending GI intermediate channels 45 mm (0.90 mm thick with two flanges of 15 mm each) from the soffits @ 1220 mm center to center with ceiling angle of width 25x10x0.55 mm thick fixed to soffits with G.I cleat and steel expansion fasteners ceiling section of 0.55 mm thick having knurled web of 51.50 mm and two flanges of 26 mm each with lips of 10.50 mm are fixed to the intermediate channel with the help of connecting clips in direction perpendicular to the intermediate channel at 457 mm centers 10 mm thick tapered edge hilux board (confirming to IS 2035 – 1982) screw fixed to ceiling section with 25 mm dry wall screws @ 230 mm centers screw fixing is done mechanically either with screw driver or drilling machine with suitable attachment. the size and shapes of false ceiling, pattern and drops as per drawing the measurement taken as exterior visible surface only, the rate inclusive of all materials, labour charges, joint putty, down rods with anchor fastener, cloud ceiling scaffolding charges and other hardware items etc all complete and as directed by the Departmental Officer.

14400

-

-

... More
Supplying and Installing Metal False Ceiling using Fire Retardant Galvanized Steel Sheet perforated/ CNC cut curtain / Plain lay in tile size 600mm x 600mm, 0.5mm thick, powder coated on external surface and shall have flange on all four sides to rest on the exposed grids. The system to give 600mm x 600mm centre to centre 'T'. The 'T' shall be not be dipped GI Tee Section 3600mm long main Tee. 24mm wide and cross Tee panels are formed by running main runner of 'T' section of size 30mm x 24mm powder coated at bottom at intervals with powder coating at bottom. Necessary provision of inter locking of 'T' section are made at required intervals not exceeding 600mm. The main runners are suspended from the ceiling by means of 4mm dia. GI rods fixed to the ceiling using anchor fasteners of 50mm x 8mm size with nylon inset and hooked to the main rubbers using clips. The last hangers at end of each rubber should not be greater than 600mm from the adjacent wall. The panel has been plain or perforated as per the drawing. The last panel shall be placed at the side wall using edge profile 'L' Angle of size 20mm x 20mm and fixed to the side wall the false ceiling should be fixed of same level and should present a neat look etc., as per architectural drawings, standard specification and as per the direction of Engineer in-charge.

2900

-

-

... More
Providing & Applying high quality acrylic modified resin based texture of any Pattern with anti algae and UV resistance properties to be applied as intermediate finish in desired pattern @ 43.04 kg/10 sqm to form film of 1- 1.5 mm thickness after scrapping and properly cleaning the surface to remove loose particles from the plaster surface, followed by top coating with Premium Acrylic Smooth interior / exterior paint with Silicone additives of required shade by two or more coats @ 1.43 litre/10 sqm, the colour, shade and pattern as per architectural drawing etc all complete as the direction of Engineer -in- Charge.

7900

-

-

... More
Supply and installation of Anutone (or) Equivalent Brand of Acoustical False Ceiling of Sisoli Serene / Slate Spirts / Slate Polka Mineral Fibre/ GRG Core Ceiling Tiles of size 595 x 595 x 15mm having volume density 270 kgs / m3, weight 4kg / m2 which is suspended by using 0.3mm thick skelet trelis T15 metal grid system. The skelet trelis T15 metal grid system of 600 x 600mm module includes skelet WA15 W30 wall angle with unequal flanges of 15 / 19mm, length 3000mm, fixed along the perimeter of walls with the help of nylon sleeves and suitable fasteners at 300mm centers. Then suspend the skelet MT15 W36 MainT with flange width 15mm, height 32mm and length 3600mm, from the soffit slab with help of soffit cleat and wire rod with leveling spring clip at 1200mm centres. Skelet CT15 W12 Cross T with flange width 15mm, height 26mm and length 1200mm is interlocked into the pre-cut slots in the Main T15 at 600mm centers in the perpendicular direction to the Main T15. Finally skelet CT15 W06 Cross T with flange width 15mm, height 26mm and length 600mm are interlocked into the precut slots in the CT15 W12 Cross T in direction parallel to the Main T15 to result in 600 x 600mm module. Sisoli Serene / Slate Spirts / Slate Polka of size 595 x 595 x 15mm shall be placed into the grid size of 600 x 600mm. The systems to achieve noise reduction coefficient not less than 0.5 NRC, so as to have an neat appearance as directed by the department offices. The cost includes, cost of material, cost of labour, Scaffolding, transportation, conveyance, etc., complying to standard speciation.

4120

-

-

... More
Brick jelly concrete 20mm gauge in pure burnt lime stone slaked and screened (No Sand) over RCC Roof Slab with proportion of brick jelly to lime (fat lime) being 32: 12 1/2 by volume well beaten with wooden beaters for giving the required slope and thickness in all floors complying with relevant standard specification and as directed by the departmental officers.

1900

-

-

... More
Providing and Placing in position suitable PVC water stops conforming to IS:12200 for construction/expansion joints between two RCC members and fixed to the reinforcement with binding wire before pouring concrete etc. complete

1150

-

-

... More
Supply and installation of fire doors single leaf door of dimensions, of Thickness 46mm, Honeycomb In-fill, Door Hinges 4" x 3" x 3mm, Double Ball Ball bearing Butt Hinges Grade SS 304 - Finish SS Dead Lock with both side key Fire rating as 2 Hrs. The shutter thickness 1.00mm Galvanised and frame sheet thickness 1.6mm GI. Honey core as in fillable material and profile 2.52 and 3.15, respectively. Vision Panel 200 x 300mm 2 Hrs. Fire Glass Schott Pyran with Frame the door mounting as brick or concrete. The cost includes transportation, installation, labours, and all necessary hardware such as (Door closer with standard arm srishan, Dead lock with cylinder, D' handle (250mm), Clear glass (200mmx300mm) with foam tape and Installation kit). The frame of the doors, the orientation of the doors and the colour of the doors are as per the architectural drawings.

-

-

-

... More
1.20m x 2.40m

53

-

-

... More
1.00 x 2.10m

74

-

-

... More
Supply and installation of fire doors dobule leaf door of dimensions, of Thickness 46mm, Honeycomb In-fill, Door Hinges 4" x 3" x 3mm, Double Ball Ball bearing Butt Hinges Grade SS 304 - Finish SS Dead Lock with both side key Fire rating as 2 Hrs. The shutter thickness 1.00mm Galvanised and frame sheet thickness 1.6mm GI. Honey core as in fillable material and profile 2.52 and 3.15, respectively. Vision Panel 200 x 300mm 2 Hrs. Fire Glass Schott Pyran with Frame the door mounting as brick or concrete. The cost includes transportation, installation, labours, and all necessary hardware such as (Door closer with standard arm srishan, Dead lock with cylinder, D' handle (250mm), Clear glass (200mmx300mm) with foam tape and Installation kit). The frame of the doors, the orientation of the doors and the colour of the doors are as per the architectural drawings.

-

-

-

... More
1.50m x 2.40m

51

-

-

... More
Supplying and Erecting Pull and Push Type Rolling Shutter with ISI make of approved size and section using 18 GI sheet. The shutter shall be painted with one coat of red oxide primer and the rate is inclusive of hood covers, transportation charges etc Rolling shutters (WITH ISI MONOGRAM) as per the drawing and standard specifications as directed by Engineer in-charge.

-

-

-

... More
a) Gear Operated Type

18

-

-

... More
b) Electrically Operated Type

200

-

-

... More
Supplying and fixing of single leaf Solid Core Flush shutters with commercial ply on both side with teakwood lipping alround 35mm thick both sides finished with 1mm thick laminated sheet and edges are finished with pvc edge banding tape and fixing with Brass furniture fittings such as 5 no's 125x30mm hinges, 1 No of brass Tower bolt 400mm long and 12mm dia, 2 Nos 200mm ornamental brass Handle, Mortice Lock with required screws with 3 Keys With Night latch, 1No 40mm dia & 60mm long rubber bush, 1 no Door stopper with rubber bush, Hydraulic Door Closer (heavy duty) with required Brass screws, labour charges for wrought and put-up and fixing in position of flush shutters, the door with bottom with or without PVC louver arrangement, etc all completed as directed by the departmental officers.

-

-

-

... More
a) Flush door shutter size 900x2400 (Single leaf)

133

-

-

... More
b) Flush door shutter size 1000x2400 (Single leaf)

5

-

-

... More
Supplying and fixing of 20mm thick bituminous expansion joint filler pad of approved quality and make inclusive of conveyance charges, cutting the pad to the required size, cost of materials and labour charges for fixing in position wherever necessary for all floors etc., complete and as directed by the departmental officers.

1789

-

-

... More
Expansion Joint filling with Polysulphide sealant upto 50mm width - Horizontal Providing and laying with two-part elastomeric fuel resistance, UV resistant, Non-toxic once cured, resistant to flame, pouring grade liquid polysulphide sealant to fill the expansion joint, Control joints in parking area, construction joint in airport runway, Tanks, bridges & concrete roads. The sealant shall have Elongation min. 450% confirms to ASTM D 412, movement accommodation for butt joint 25% & for lap joints 50%. The sealant should meets the requirement of BS 5212, BS 4254 & ISO:11600. Ensure that apply a coat of polysulphide sealant primer @0.5L/m2 to get better adhesion on prepared surface before placing the sealant with both side SS 2mm thick L angle 30mm and the top of the expansion joint fixed with 2mm thick and 150mm wide SS/Aluminium sheet one side fixed with screw other side free. The finished cost including surface preparation, filling foam backer rod, applying masking tape on both sides of the joint & polysulphide sealant filling on gap completely as per specification.

1000

-

-

... More
Expansion Joint filling with Polysulphide sealant upto 30mm width - Vertical Providing and laying with two-part elastomeric UV resistant, non-toxic gun grade liquid polysulphide sealant to fill the expansion joint, sealing joints in water retaining structure. The sealant shall have Elongation min. 500% confirms to ASTM D 412, movement accommodation for butt joint 25% & for lap joints 50%. The sealant should meets the requirement of BS 4254 & ISO:12118. Ensure that apply a coat of polysulphide sealant primer @0.5L/m2 to get better adhesion on prepared surface before placing the sealant with both side SS 2mm thick L angle 30mm and the top of the expansion joint fixed with 2mm thick and 150mm wide SS/Aluminium sheet one side fixed with screw other side free. The finished cost including surface preparation, filling foam backer rod, applying masking tape on both sides of the joint & polysulphide sealant filling on gap completely as per specification.

2000

-

-

... More
Design, supplying and fixing of 200*50*2.5mm free standing aluminium fins specially designed extruded powder coated section with necessary back aluminium support to strengthen the fins. The cost including all materials, labour charges, scaffolding charges, higher charges of machinery, tools and plants, necessary hardware items for fixing etc., as per architectural elevation drawing and standard specification, all complete as directed by the Engineer in-charge.

6000

-

-

... More
Supplying and fixing of HPL toilet cubicle unit of Size- 1200mm(W) X 1500mm(D) X 2000mm(H), Thickness of Compact Laminate: 12mm, door Size 600mm * 1783mm with fixing accessories stainless Steel & Aluminium as per drawing SS 304 Gravity hinges SS 304 Coat Hook with door Stopper, SS 304 Doorknob, SS 304 Lockset with indicator, SS 316 Adjustable leg aluminium U channel With SS Finish, aluminium top rail with SS Finish, Aluminium Door Stopper Channel SS Finish, SS 304 Screws and Noise Defending Tape, the cost includes transportation, installation, labours, and all necessary hardware. The colour and shape as per the architectural drawings etc., as per standard specifications.

300

-

-

... More
Manufacturing, supplying and fixing Precast Reinforced Cement Concrete perforated / plain slabs of 100mm thickness and size as per drawing using M25 grade concrete, using following HBGS jelly including cost of reinforcement steel in position but including cost of moulding charges, casting of slab with necessary lifting hook, finishing, curing and fixing in position in all floors steel reinforcement as per structural drawing etc., complete complying with standard specification and as directed.

2130

-

-

... More
Supplying and fixing of dobule leaf Soild core flush door shutters using boiled water resistance (BWR) teak wood ply as per IS 303-1989, the cross band and face veneers are to be banded with phenol formaldehyde synthetic resin in hot press both sides and manufacturing the shutter by using quality timber of termite proof and seasoned to moisture content not more than 10%, hot pressed with hydraulic press at a temperature of 150o to the norms as per IS 2002-1983 and TW Ply on Both side with teak wook lipping around, 35mm thick including cost and fixing of Brass furniture fittings such as 10 nos 125x30mm hinges, 2 No of brass Towerbolt 400mm long and 12mm dia, 4 Nos 200mm ornamental brass Handle, Mortice Lock with required screws with 3 Keys With Night latch, 2No 40mm dia & 60mm long rubber bush, 2 no Door stopper with rubber bush, 2 nos of Hydraulic Door Closer (hevy duty) with required Brass screws, labour charges for wrought and putup and fixing in position of flush shutters and as directed by the departmental officers. Flush door shutter size 1500x2400 (Double leaves)

210

-

-

... More
Supply and laying concrete tiles superior variety such as (Hindustan / Eurocon tiles / Tactile etc.) for flooring in CM 1:3 (One of Cement and three of sand) 20mm thick, including fixing in position, cutting the tiles to the required size wherever necessary, pointing the joints with colour cement, finishing, curing etc complete and as directed by the departmental officers.

1000

-

-

... More
Providing and laying in position, Standardised Concrete Mix M-25 Grade in accordance with IS:456-2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 350 kglms and maximum water cement ratio of 0.45, including admixture (plasticiser / superplasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (0.5 cu.m.) 773 kg. of 20mm machine crushed stone jelly and with about (0.33 cu.m.) 515.6 kg. of 10-12mm machine crushed stone jelly and with about (0.479 cu.m') 767 kg. of sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers. The coarse and fine aggregates to be used should comply with the requirements of IS Standards and cement is OPC/SRC as per design and as directed by the departmental officers. (No separate payment will be made by the Department for the excess usage of materials).To meet the LEED certification, required ingredients such as fly ash/GGBS to be added in required proportion to meet the strength requirements.

-

-

-

... More
a) 1.50m depth and upto 4.5m depth below ground level

316

-

-

... More
b) In foundation and basement (-1.5 to plinth level)

2023

-

-

... More
c) in Ground floor

471

-

-

... More
d) First floor

340

-

-

... More
e)Second floor

340

-

-

... More
White washing two coats with freshly burnt white shell lime in all floors including cost of lime, blue powder fevicol type gum, brushes, scaffolding charges, etc., complete complying with standard specification and as directed.

2900

-

-

... More
Finishing the top of Terrace floor with one course of solar reflective water proof, heat proof and cool roof ceramic tiles of size 300mmx300mmx8mm thick of approved quality laid in cement mortar 1:3 (one part of cement and three parts of sand) 20mm thick cutting the tiles to the required size with special cutter wherever necessary, laying in position and pointing with white cement at the rate of 0.3 Kg. / sq. m. no exces payment made for wastage of materilas, all the waste materials are disposed from the site etc., complete complying with standard specification.

1880

-

-

... More
Plastering in cm 1:5 (One of cement and five of sand) 12mm thick for border finish in all floors for elevation purposes, including scaffolding, curing, finishing etc., all complete.

380

-

-

... More
Providing and Laying Plain Cement Concrete in foundation and basement 1:2:4 (one cement, two M.sand and four hard broken stone jelly) using 20mm jelly inclusive of shoring, strutting, centering and bailing out water wherever necessary ramming, curing etc., complete in all respects complying with relevant standard specifications and as directed by the Departmental officers. (in all heights and all depths) To meet the LEED certification, required ingredients such as fly ash/GGBS to be added in required proportion to meet the strength requirements.

140

-

-

... More
Manufacturing, supplying and fixing Precast Reinforced Cement Concrete perforated / plain slabs of 125mm thickness and size as per drawing using M25 grade concrete, using following HBGS jelly including cost of reinforcement steel in position but including cost of moulding charges, casting of slab with necessary lifting hook, finishing, curing and fixing in position in all floors steel reinforcement as per structural drawing etc., complete complying with standard specification and as directed.

1430

-

-

... More
Supplying and fixing of PVC 110mm dia 6Kg/cm2 pipe of 0.1m to 0.2m length, 1no of CI Grating including cost of labour charges for cutting, fixing and cost of materials etc complete complying with standard specifications and as directed by the departmental officers.

400

-

-

... More
Providing weep holes in stormwater drain with necessary 110mm dia pipe (6kg/m2) 0.20m length, wire mesh screen, necessary filling as per drawing etc complete complying with standard specifications and as directed by the departmental officers.

1890

-

-

... More
Providing rainwater harvesting system as per the drawing with necessary earth work, outer ring, perforated RCC cover slab with removable Ms gratings, filling material like Gravel, loose boulders and aggregate, 300 mm dia boring up to 10.0m depth, providing 160 mm dia pvc slated pipes up to 6.0m with necessary nylon mesh, SS mesh at top, including filling materials as per drawing etc, all complete complying with standard specifications and as directed by departmental officers

90

-

-

... More
Supply and fixing of sheets out of 0.47 mm TCT coated galvalume sheets, rate including all materials, labour charges, scaffolding, staging, transportation, lead & Lifts, wastage, etc,. No separate payment made for bolts, nuts, self driving screws, washers, welding, over lap of sheer as per drawing etc., all complete, as directed by the departmental officers.

350

-

-

... More
Supplying, Fabrication & Fixing of Eaves Gutter made out of 0.50 mm TCT Coated Galvalume sheets with necessary Strips, including cost of necessary fixing accessories, labour charges, scaffolding etc., all complete, as directed by the departmental officers.

46

-

-

... More
Garbage Stroage Bins of capacity 600 liters HDPE/PVC Storage bins with Wheel mounted or trolley mounted. Waste Garbage Bins shall be colour coded & Heavy Duty Sunproof Tight-fitting, overlapping lid to help contain odors. Colour : Green, Blue & Yellow

20

-

-

... More
Garbage Stroage Bins of capacity 120 liters HDPE/PVC Storage bins Waste Garbage Bins shall be colour coded & Heavy Duty Sunproof Tight-fitting, overlapping lid to help contain odors. Colour : Green, Blue & Yellow

20

-

-

... More
Segregation Table As per vendor design to handle the required capacity of daily waste made of Stainless steel

1

-

-

... More
Weighing Scale Electronic Weighing Scale, Capacity 100 Kg

1

-

-

... More
Bag packing Machine: Small bag packing machine to pack compost bag, sutable to pack 25-50 kg bag

1

-

-

... More
Manual Handling Trolley Stainless Steel Platform Trolley Load Capacity 100 to 150 kg Strong, rigid, steel handle for secure maneuvering of loads 4 ball bearing wheels for easy and safe steering. Compact design for easy storage.

1

-

-

... More
Supplying and installation of Chain Link - 2" x 2" using 10 Gauge Galvanised Iron PVC insulated Wire with Barbed Wire - 10 Gauge - Two Ply and Four Pronged (Galvanised) for top, middle and bottom support to hold the chain link fencing including cost of material, labour charges, necessery hardware materials like bolt, nut & washers etc., complete as per standard specificatins and as directed by the departmental officers.

1100

-

-

... More
Supply and planting different varieties of curtain creeper (Vernonia or equivalent) planting in position without damage of roots, excavation of pit size 200mm x200mm x 300mm and backing filling of topsoil or equilent fertile soil, compost,bio-pesticides with proper staking and wrapping. Rate includes plant cost, soil mixtures, transport, supervision and labour charges etc., all complete and as directed by the deparmental officers

1400

-

-

... More
Manufacturing, supplying and fixing in position plain cement concrete precast kerb slab of size 600mm x 300mm x 165mm in Cement Concrete 1:3:6 (One cement, three sand and six jelly) using 20mm HBG stone jelly including cost of moulding charges, casting of slab, finishing, curing, fixing and pointing the slab with CM 1:3 (One Cement and Three Sand) to full depth of slab etc., complete complying with standard specification and as directed by the Engineer in charge

4150

-

-

... More
Construction of Granular Sub - Base (GSB) to the required compacted thickness (Drainage layer) by providing approved Coarse graded material conforming to Grading-V of Table 400 - 1 and satisfying the physical requirement for material for GSB as per Table 400 - 2 of MORTH Rev -5 including screening, spreading in uniform layers with motor grader on prepared surface, watering and premixing by mix in place method with rotavator at OMC, and compacting with Vibratory roller 80 to 100 KN static weight to achieve the desired density and fine dressing to required grade and cross slope as directed by the SIPCOT officers etc., complete including obtaining and transporting all materials from approved quarry site to work site with all lift and lead by mechanical transport, head load or any other mode of transporation including cost and conveyance of all materials, labour charges,hire charges and fuel charges for loader, water tanker with sprinkler,motor grader, vibratory road rollers and all other equipments, tools and plants, safety measures, testing required including all other incidental charges, etc., complete as per the standard specification as per clause 401 of MORTH Rev.-5

7900

-

-

... More
Supplying and laying Interlocking Rubber Moulded Hydraulic Pressed Paver Block 83mm tk Terracotta colour or gray colour paver block with M40 grade cement concrete using 6mm chips including levelling the base preparation of sub base, laying out the paver, cut the places to fit the edge, vibrating the pavers and sweeping the sand (grouting) and transportaion chrges loading and unloading charges, all taxes and laying charges etc., complying with std., specification.,

29000

-

-

... More
Supplying and laying Interlocking Rubber Moulded Hydraulic Pressed Paver Block 63mm tk Terracotta colour or gray colour paver block with M30 grade cement concrete using 6mm chips including levelling the base preparation of sub base, laying out the paver, cut the places to fit the edge, vibrating the pavers and sweeping the sand (grouting) and transportaion chrges loading and unloading charges, all taxes and laying charges etc., complying with std., specification.,

2400

-

-

... More
Providing, laying, spreading and compacting graded stone aggregates for Wet Mix Macadam 250mm thick, including premixing the materials with water at OMC in mechnanical mix plant, conveyance of mixed materials by tipper to site, laying in uniform layers using pavers in Sub Base/ Base course on well prepared surface and compacting with vibratory roller to acheive the desired density including cost of material, labour charges, rentals for machinery, fuel and all other incidental charges etc., complete as per clause 406 of MORTH Rev-5

7900

-

-

... More
Providing and laying in position, Standardised Concrete Mix M-30 Grade in accordance with IS:456-2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 400 kglms and maximum water cement ratio of 0.45, including admixture (plasticiser / superplasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (0.5 cu.m.) 773 kg. of 20mm machine crushed stone jelly and with about (0.33 cu.m.) 515.6 kg. of 10-12mm machine crushed stone jelly and with about (0.479 cu.m') 767 kg. of sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers. The coarse and fine aggregates to be used should comply with the requirements of IS Standards and cement is OPC/SRC as per design and as directed by the departmental officers. (No separate payment will be made by the Department for the excess usage of materials).To meet the LEED certification, required ingredients such as fly ash/GGBS to be added in required proportion to meet the strength requirements.

-

-

-

... More
a. In Foundation and basement below 1.50m depth and upto 4.5m depth below ground level

420

-

-

... More
b. In Foundation and basement

270

-

-

... More
4.50m depth and upto 9m depth below ground level

250

-

-

... More
Ground floor

30

-

-

... More
Providing and fixing of PVC mould CI Steps and having manufacture's permanent identification and ISI mark to be visible even after fixing, including fixing in manholes/ chambers/sump etc. all complete complying with standard specifications

596

-

-

... More
Supply and delivery at site and fixing of SFRC manhole cover with frame arrangement of opening heavy duty to with stand any type of impact load if any, confirming to I.S.I specifications and as directed by the departmental officers

-

-

-

... More
600mm x 600mm

24

-

-

... More
Applying one coat of anticorrosive treatment on steel reinforcement rods (20 ltrs. Of anitcorrosive chemical for one mertic tonne of steel reinforcement rods) at site including a cost of required quantity of anticorrosive chemicals, (best approved quality) cement, consumables such as brushes, gloves and labour for anticorrosive coating etc. complete and as directed by the PMC/Employer. (The Quantity and brand of anticorrosive chemaical should be got approved by the PMC/Employer

90

-

-

... More
Supply & Fixing of MS Handrail of 1.2m height with Vertical support 32mm dia pipe 2.6mm thick at every 0.9m c/c and top horizontal 40mm dia 2.9mm thick pipe, intermediate horizontal and bottom horizontal 32mm dia pipe 2.6mm thick with necessary welding, cost including preparation of surface, all MS members shall be painted with anti corrosive paint, with two coats of 1st class synthetic enamel paint of complete, as directed by the Engineer-in-charge.

25

-

-

... More
Note : 1. "Procurement of items with astehetic value and visibility shall be on prior approval of architect and project office/PMC for specific arae of application."

-

-

-

... More
Supplying and fixing in position white / colour glazed European Water Closet of best quality and approved make with 100 mm "P" or "S" trap connecting with CI pipe of 100mm dia / PVC pipe of 110mm dia, double flapped rigid PVC black seat and seat cover with CP brass hinges including cost of white cement, cement for packing, spun yarn, teak wood plugs, brass screws, etc., including supplying and fixing 10 litres capacity PVC / 12.5 litres capacity porcelin low level flushing tank with a pair of CI brackets, etc., complete with all fittings such as 15mm brass ball valve with polythene float with brass handle, union, coupling connected by means of 40mm white PVC flush hand using Indian adopter joint including all internal fittings such as 15mm brass connections, 15mm GM wheel valve, 15mm brass nipple (2 Nos.), 15mm nylon connection, TW plugs, screws and also giving necessary connection to the PVC pipe including cost of 600mm length of 110mm dia PVC pipe and painting the CI brackets with 2 coats of approved paint over one coat of red oxide primer, dismantling the masonry and re-doing the dismantled masonry to original condition etc. complete complying with standard specifications. (The EWC and flushing tank wiht all accessories should be got approved by the Enginer incharge before use on works) (wall mounted)

255

-

-

... More
Supply and fixing of oval shape wash basin colour of size 550 x 430mm of best approved quality with ISI mark including cost and fixing of bracket, PVC waste pipe, required grating, C.P.trap, Bob cock, PVC connections, C.P.waste plug with aluminium chain including labour charges for fixing clamps screws and solution of white cement etc. all complete in all respects as directed by the complete complying with standard specification and as directed by the PMC/Employer. (The wash hand basin and specials should be got approved by the PMC/Employer before use on works).

320

-

-

... More
Supplying and fixing in position best quality and approved make Indian made Ornamental Type White Glazed Porcelain Corner ‘L’ Type Wash Hand Basin (with pedestal / without pedestal) with a pair of cast iron brackets, including cost 15mm dia brass CP pillar tap, 32mm dia "B" class GI waste pipe with rubber plug and chain, 15mm dia GM wheel valve, 15mm brass nipple, 15mm dia nylone connection, 32mm dia CP brass waste coupling including fixing of wash basin using CI brackets on to the wall in position with TW plugs and screws, rubber washers, white lead and giving necessary water supply connection and painting the brackets with two coat of painting over a priming coat of anti-corrosive paint including testing for leakages etc., complete complying with standard specification and as directed by the PMC/Employer. (The wash hand basin and specials should be got approved by the PMC/Employer before use on works).

2

-

-

... More
Supplying and fixing of Indian Water Closet white glazed (oriya type) of size 580 mm X 440 mm of approved make with ISI mark (to be got approved from EE before use) with PVC SWR grade 'P' or 'S' trap, including concrete filling the sunk portion with brick jelly lime concrete proportion of brick jelly to lime being 32:12½ by volume (32 cft of 20mm gauge brick jelly and 12 ½ cft of slaked lime) (No sand) and top 75mm thick brick jelly concrete in CC 1:8:16 (one of cement, eight of sand and sixteen of broken brick jelly) using 40mm size brick jelly including plastering the sides of sunk portion in Cm 1:3 (one of cement and three of sand) 12mm thick mixed with water proofing compound at 2Kg / m2 and top left rough to receive the floor plastering but including antisyphonage connection, one coat of bitumen for the sides , bottom and curing etc., complete complying with standard specification and as directed by the PMC/Employer. in all floors.

56

-

-

... More
Supplying and fixing of White Glazed Porcelain URS-WHT-13253N Urinal with fixing Accessories, Size: 385x325x635 mm SNR-51097 Sensor Flushing Valve for Urinal with Complete Kit (Battery Operated) (Suitable For Urinal URS-WHT-13255) spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required etc., complete complying with standard specification and as directed by the PMC/Employer.

112

-

-

... More
Fixing & testing of curved shaped urinal partition of size 600 x 1200mm, 12mm thick toughend frosted glass including providing & fixing concealed SS bracket, hire charges for tools and plants, curing, finishing true to plumb etc., all complete in all floors as directed by the departmental officers.

84

-

-

... More
Providing and fixing 15mm dia CP/SS Jet with flexible tube upto 1.2 metre long with ss Triangular plaste to European Type WC of quality & make as approeved by engineer in charge etc., complete complying with standard specification and as directed by the PMC/Employer.

120

-

-

... More
Supply, Installing, testing and commissioning of 15 mm dia CP Two Way Bib Cock with stainless steel Health Faucet of approved make (ISI) and quality. The item rate including all costs towards labour, tools, tackles & machineries, all leads & lifts, work related cleaning, confirming to I.S. specification including cost and labour charges for fixing etc., complete complying with relevent standard specifications complete.

255

-

-

... More
Supplying and fixing of 15mm dia C.P. Angle cock with fittings of approved make (ISI) and quality including cost and labour charges for fixing etc., complete complying with relevent standard specifications complete.

56

-

-

... More
Supply, installation and fixing of Toilet Paper Holder in CP brass on the wall of approved make (ISI) and quality including cost and labour charges for fixing etc., complete complying with relevent standard specifications complete.

283

-

-

... More
Supply, Storing and fixing of ABS body Liquid soap dispenser with SS screws on the wall of approved make (ISI) and quality including cost and labour charges for fixing etc., complete complying with relevent standard specifications complete.

118

-

-

... More
Supply, Storing and fixing of Stainless steel body paper towel dispenser with SS screws on the wall of approved make (ISI) and quality including cost and labour charges for fixing etc., complete complying with relevent standard specifications complete.

118

-

-

... More
Supply and Installation in position Hand Drier, fixed on wooden cleats with CP brass screws and washers including drilling hole in walls with drill gun and making good the walls of approved make (ISI) and quality including cost and labour charges for fixing etc., complete complying with relevent standard specifications complete.

89

-

-

... More
Supplying and fixing best approved best quality brass CP soap tray of size 150 x 150mm including cost of teak wood plugs, brass screws, etc., complete complying with standard specifications. (The soap tray should be got approved by PMC/Employer before use on works). shower area only

2

-

-

... More
Supply, installation and fixing of Robe hook with zelos accessories &. brass screw as required of approved make (ISI) and quality including cost and labour charges for fixing etc., complete complying with relevent standard specifications complete.

283

-

-

... More
Supplying and fixing approved best quality brass CP towel rail 600mm long and 20mm dia with brackets of same materials including cost of teak wood plugs and CP screws, etc., complete complying with standard specifications.(The tower rail should be got approved by PMC/Employer before use on works). shower only

2

-

-

... More
Supply, Installation and Testing of best quality stainless steel single bowl pantry sink single bowl With/without drain board of size 600mm x 600mm x 200mm, inclusive of sink cock, angular stop cock, bottle trap, 40mm dia CP waste coupling, 40mm PVC waste pipe as directed by the Architects / Site Incharge etc., complete complying with relevent standard specifications complete.

1

-

-

... More
Supply, Installation and Testing of best quality stainless steel single bowl With/without drain board fo sink size 600mm x 450mm x 200mm, inclusive of sink cock, angular stop cock, bottle trap, 40mm dia CP waste coupling, 40mm PVC waste pipe as directed by the Architects / Site Incharge etc., complete complying with relevent standard specifications complete.

56

-

-

... More
Supplying and fixing of 15mm dia CP swan neck tap ornamental type heavy of approved make (ISI) and quality including cost, labour charges for fixing etc all complete and as directed by the Architects / plumbing drawing / Site Incharge etc., complete complying with relevent standard specifications complete.

1

-

-

... More
Supply, installation and fixing testing and commissioning of Horizontal approved make electically operated storage water heater inner container made from copper or stainless steel with Glass Wool / Puf Insulation with230V / 1000W including the remal instalation safety valve, vacuum relief valve, neon lamp, mounting brackets, angle valve, connection hose installing in position with coach screws or bolts, nuts, testing, commissioning (Higher End),etc., complete complying with standard specification and as directed by the PMC/Employer.

-

-

-

... More
a) 25ltrs capacity (Pantry counter)

3

-

-

... More
b) 25ltrs capacity (Dish wash)

2

-

-

... More
Supply and Installation of Grab Bar with 32mm dia, 2mm thick SS-304 grade supported on 5mm thick 76mm dia, SS cover with pre-drilled holes for counter sunk screws the length of grab bar as per plumbing drawing the cost ncluding all materials, labour charges, other hardware items for fixing and redoing the works in original position etc., complete complying with standard specification and as directed by the PMC/Employer.

28

-

-

... More
Supply and Installation of L type Grab Bar with 32mm dia, 2mm thick SS-304 grade supported on 5mm thick 76mm dia, SS cover with pre-drilled holes for counter sunk screws the length of grab bar as per plumbing drawing the cost ncluding all materials, labour charges, other hardware items for fixing and redoing the works in original position etc., complete complying with standard specification and as directed by the PMC/Employer.

28

-

-

... More
Receiving, Storing ing, Installing & testing of completed shower set including wall mixer with diverter, shower arm with sliding Shower rose on a vertical rail the cost ncluding all materials, labour charges, other hardware items for fixing and redoing the works in original position etc., complete complying with standard specification and as directed by the PMC/Employer. Complete set of approved makes.

2

-

-

... More
Supply, storing, insatlling, testing & commissioning of 15mm dia angle cock with Wall Flange the cost ncluding all materials, labour charges, other hardware items for fixing and redoing the works in original position etc., complete complying with standard specification and as directed by the PMC/Employer. Kitchen & Pantry)

7

-

-

... More
Supply, Installing, testing and commissioning of 15m dia CP sink mixer , CP waste coupling, 32mm dia CP bottle trap with extension pipe, and CP wall flanges, the cost ncluding all materials, labour charges, other hardware items for fixing and redoing the works in original position etc., complete complying with standard specification and as directed by the PMC/Employer Flow restrictor(1.4LPM)

1

-

-

... More
Providing, Fixing, Jointing, Testing and Commissioning of Rigid uPVC Pipe for Soil, Waste Installation confirming to IS 4985 Class 3 PN 6 and fitting confirming to IS 7834. Cut to required lengths including all necessary fitting and specials such as bends, junctions, offsets, acess pieces (plain or door). The pipes shall be running over slab (in -filling) / concealed in wall in areas such as toilets, kitchen etc. Cost shall be inclusive of providing and laying 1:2:4 cement concrete below the joints of pipe. Cost shall be inclusive of making maximum of 100mm X 100mm chasing in wall / floors for the pipe; making good the same using 1:1 cement mortar over the embedded pipes and fittings, complete as required. If running through ceiling level cost shall be inclusive of galvanized clamps, hangers, anchor fastners at maximum of 1m interval the cost ncluding all materials, labour charges, other hardware items for fixing and redoing the works in original position etc., all complete complying with standard specification and as directed by the PMC/Employer.

-

-

-

... More
40mm dia

365

-

-

... More
50mm dia

220

-

-

... More
Supplying and fixing the following dia uPVC (SWR) pipe with ISI mark conforming to IS 13952:1992- type 'B' for soil line with relevant specials conforming to IS 14735 including jointing with seal ring conforming to IS 5382, fixing the pipes into walls with necessary wooden plug, screws, holding wherever necessary and making good of the dismantled portion with necessary connections to sanitary fittings, Cut to required lengths including all necessary fitting and specials such as bends, junctions, offsets, access pieces (plain or door), Vent Cowls with brass mosquito proof . Cost shall be inclusive of Fixing / Supporting the Pipes at Wall / Ceiling level supported by galvanized clamps, hangers, angle brackets, anchor fasteners the gaps around the pipes must be filled with filling materials as per the plumbing drawing with minimum warranty period of 10 years etc., all complete complying with standard specification and as directed by the PMC/Employer.

-

-

-

... More
75mm dia

1570

-

-

... More
110mm dia

1550

-

-

... More
Supplying and fixing in position PVC cowls of following dia of best approved quality conforming to BIS, the cost ncluding all materials, labour charges, other hardware items for fixing and redoing the works in original position etc., complete complying with standard specification and as directed by the PMC/Employer. (The PVC cowl should be got approved by the Executive Engineer before use on works).

-

-

-

... More
200mm dia

12

-

-

... More
110mm dia

12

-

-

... More
75mm dia

24

-

-

... More
Providing, fixing and testing C.I multi floor trap of self cleansing design with arm and provision for connection C.I /G.I pipe inlet fitting complete including cost of cutting and making good the walls and floors wherever required. Multifloor trap 75 mm outlet with 100 mm inlet the cost ncluding all materials, labour charges, other hardware items for fixing and redoing the works in original position etc., complete complying with standard specification and as directed by the PMC/Employer

382

-

-

... More
Providing, fixing and testing C.I multi floor trap of self cleansing design with arm and provision for connection C.I /G.I pipe inlet fitting complete including cost of cutting and making good the walls and floors wherever required. Multifloor trap 75 mm outlet with 100 mm inlet the cost ncluding all materials, labour charges, other hardware items for fixing and redoing the works in original position etc., complete complying with standard specification and as directed by the PMC/Employer (URINAL)

56

-

-

... More
Providing and fixing heavy duty S.S. Floor Clean out with frame of approved design including setting in floor with cement motor to match with floor finish the cost ncluding all materials, labour charges, other hardware items for fixing and redoing the works in original position etc., complete complying with standard specification and as directed by the PMC/Employer.

9

-

-

... More
Providing, Fixing, testing and commissioning in position PVC Clean Out with plug suitable for pipe diaMetre with a seal tight cover. Making proper connection with refined drip seal joints, bringing the same in proper condition and shape after placing it in right position complete as required and as per drawingsthe cost ncluding all materials, labour charges, other hardware items for fixing and redoing the works in original position etc., complete complying with standard specification and as directed by the PMC/Employer

-

-

-

... More
110 mm Dia

72

-

-

... More
75 mm Dia

96

-

-

... More
Designing, Providing, fixing, jointing, testing and commissioning of Pre-fabricated HDPE Centralized Grease Separator with BMS compatibility including cutter type submersible pump, medium duty cover, inlet outlet, overflow, sludge suction connection, excavation & backfilling of grease storage tank of cap minimum 400 liters including all accessories complete as required or as per manufacturer specification as and directed by PMC/Employer. suitable for below ground application, conforming to EN 1825 / DIN 4040-100 etc., complete complying with standard specification and as directed by the PMC/Employer

1

-

-

... More
Supply, installation, testing and commissioning of PVC Khurra with CI Grating - L type with necessary accessories to complete the work including threading, cutting and fixing in/on walls under ceiling, on terrace, etc.,. The quoted rate shall include for making necessary chasing, making bores in foundation, walls, slabs, etc., and making good the chased surfaces and bores in cement mortar etc., complete complying with standard specification and as directed by the PMC/Employer

-

-

-

... More
200 mm dia

12

-

-

... More
Drilling with core cutting machine in RCC beams, slabs floors up to slab thickness for laying pipes and rendering the same in RCC 1:2:4, finishing the same to the satisfaction of the owner or his authorized representative etc., including nominal reinforcement wherever required, . The quoted rate shall also include for providing EPOXY based water proofing compound for sealing the joints around the pipes with suitable material, nominal reinforcement wherever required for all levels/ all height, after approval of PMC/Employer etc complete. Measurement shall be taken for the depth of holes in running Metre for specified diaMetre. Holes shall made by authorized approved agency.with suitable material, nominal reinforcement wherever required for all levels/ all height, after approval of PMC/Employer etc complete. Measurement shall be taken for the depth of holes in running Metre for specified diaMetre. Holes shall made by authorized approved agency etc., complete complying with standard specification and as directed by the PMC/Employer

-

-

-

... More
upto 150mm Dia

702

-

-

... More
Supplying, fixing, testing and commissioning of approved make chlorinated polyvinyl chloride (CPVC) pipes, fittings SDR 11 ASTM CTS, for the following dia, pipes with necessary specials elbows, tee, reduce, plug, union, bend, couple, nipple, GM gate valve, GM check, GM Air release valves and GM wheel valve wherever necessary including labour below ground level(or) fixing on walls fully concealed to the proper gradient and alignment etc., complete complying with standard specification and as directed by the PMC/Employer. (Internal DWS & FWS)

-

-

-

... More
25mm Dia

3855

-

-

... More
32mm Dia

250

-

-

... More
Supply, installation and testing of UPVC SCH 80 pipes conforming to ASTM D 1785 and fittings of ASTM D 2467 at 300 psi to 150 psi working pressure. The scope of work including, cutting, cleaning and fixing in/on walls under ceiling, under ground etc.,. The quoted rate shall include for making necessary with necessary specials elbows, tee, reduce, plug, union, bend, couple, nipple, GM gate valve, check, GM Air release valves and GM wheel valve, chasing, making bores in foundation, walls, slabs, etc., and making good the chased surfaces and bores in cement mortar. as specified by the Consultant / Engineer-in-Charge at site inclusive of backfilling with excavated earth with proper compaction etc., below 50dia pipes included valves etc.,complete in all respects and as directed by the departmental officers ( For shaft & external)

-

-

-

... More
25mm Dia

670

-

-

... More
25mm Dia - External

385

-

-

... More
32mm Dia

265

-

-

... More
40mm Dia

1200

-

-

... More
50mm Dia

680

-

-

... More
50mm Dia - External

700

-

-

... More
65mm Dia

405

-

-

... More
65mm Dia - External

275

-

-

... More
80mm Dia

170

-

-

... More
100mm Dia

220

-

-

... More
Supply ,Installing, testing and commissioning Air release valves confirming to IS standard 13039 with necessary flanges, nuts and bolts etc., complete in all respects and as directed by the departmental officers (The item rate shall include all costs towards labour, tools, tackles & machineries, all leads & lifts, work related cleaning.) complete.

-

-

-

... More
25mm Dia

48

-

-

... More
Supply, installation, testing and commissioning approved make CI Non - return valves conforming to IS: 778 with necessary companion flanges, neoprene gaskets(10Kg/sq.cm. pressure rating) nuts and bolts including all the accessories etc.,complete in all respects and as directed by the departmental officers. ( Sample should be got approved )

-

-

-

... More
50mm Dia

2

-

-

... More
65mm Dia

6

-

-

... More
Supply, installation, testing and commissioning approved make CI Y-type Strainer conforming to IS standard with necessary companion flanges, neoprene gaskets(10Kg/sq.cm. pressure rating) nuts and bolts including all the accessories etc.,complete in all respects and as directed by the departmental officers

-

-

-

... More
65mm Dia

2

-

-

... More
80mm Dia

6

-

-

... More
100mm Dia

12

-

-

... More
Supply, fixing, testing and commissioning of CI body slim seal butterfly valves as per detailed specifications complete with vertical/horizontal liver operated unit with handle, companion flanges, gaskets, nuts and bolts etc., complete confirming to IS: 13095. The valve shall be suitable for a working pressure of 16.0 kg/sqcm etc.,complete in all respects and as directed by the departmental officers

-

-

-

... More
50mm Dia

18

-

-

... More
65mm Dia

16

-

-

... More
80mm Dia

8

-

-

... More
100mm Dia

2

-

-

... More
Supplying, installing, testing and commissioning approved make Brass pressure reducing station including pressure reducing valve ,3 Nos Isolation valves, 2 Nos Pressure Gauges with union, flanges etc.,complete in all respects and as directed by the departmental officers

-

-

-

... More
25mm Dia

16

-

-

... More
40mm Dia

4

-

-

... More
50mm Dia

12

-

-

... More
Supply ,Installing, testing and commissioning of PN 10 mechanical type float switch with an isolation valve complete confirming to IS standards, necessary flanges, nuts and bolts etc.,complete in all respects and as directed by the departmental officers (The item rate shall include all costs towards labour, tools, tackles & machineries, all leads & lifts, work related cleaning.) complete.

-

-

-

... More
40mm Dia

8

-

-

... More
Supplying, installing and testing approved make Electromagnetic flow water meter with BMS compatibility including 3 Nos Ball valves for isolation and By pass with unions etc.,complete in all respects and as directed by the departmental officers

-

-

-

... More
65mm Dia

4

-

-

... More
100mm Dia

1

-

-

... More
Fabrication & fixing of hot dip galvanized GI puddle flanges fabricated out of GI pipes and GI plates and duly hot dip galvanized after fabrication. The puddles of various diameter shall be as shown the OHT, rain water, domestic treated water, flush water, HVAC make up water storage, pump room dewatering,drawings etc.,complete in all respects and as directed by the departmental officers

-

-

-

... More
300 mm dia

2

-

-

... More
250 mm dia

4

-

-

... More
150 mm dia

12

-

-

... More
100 mm dia

63

-

-

... More
80 mm dia

8

-

-

... More
65 mm dia

12

-

-

... More
50 mm dia

4

-

-

... More
40 mm dia

16

-

-

... More
25 mm dia

34

-

-

... More
Supplying and fixing testing & commissioning of Galvanized Iron Pipes of ISI marked, I.S.1239 ('C' Class) including all G.I. Heavy duty Fittings like tees, elbows, bends, of approved make, threading, cutting, jointing & testing. Making hole openings in walls & floors. Providing galvanized steel brackets, channels, angles, flats, anchor fasteners, clamps, threaded rods, nuts, bolts washers etc. to complete the work and making good walls & floors etc., all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etccomplete. Painting the exposed G.I. pipes with Two coat of zinc chromate primer with two coats of synthetic enamel paint of approved colour / shade etc.,complete in all respects and as directed by the departmental officers (Header line) - 40mm dia

30

-

-

... More
Supplying, Installing & testing of 3 PC isolation fire proof ball valve with necessary fittings & accessories with ASME IS 17292 etc.,complete in all respects and as directed by the departmental officers

-

-

-

... More
40mm dia

2

-

-

... More
Supplying, Installing & testing of 25mm fire proof solenoid ball valve with necessary fittings & accessories with ASTM A 216 etc.,complete in all respects and as directed by the departmental officers

6

-

-

... More
Supplying, Installing & testing of 25mm pressure gauge(0 to 4 kg) with necessary fittings & accessories etc.,complete in all respects and as directed by the departmental officers

6

-

-

... More
Supplying, Installing & testing of gas leak detector with sensors control panel board, 3.5 core cables with necessary fittings & accessories etc.,complete in all respects and as directed by the departmental officers

5

-

-

... More
Supplying, Installing & testing of PRS - Regulator with inlet & outlet fitingsetc.,complete in all respects and as directed by the departmental officers

6

-

-

... More
Supplying and fixing the following dia PVC (SWR) pipe with ISI mark confirming to IS 13952 :1992 - TYPE B for soil with relevant specials conforming to IS14735 including jointing with seal ring conforming to IS 5382 with leaving a gap about 10mm to allow thermal expansion fixing the pipes into valves with necessary wooden plug, screws, holding wherever necessary and making good of the dismantled portion with necesaary connections to sanitary fittings etc.,complete in all respects and as directed by the departmental officers. (Shaft)

-

-

-

... More
75mm dia - Waste & Vent pipe

950

-

-

... More
110mm dia - Soil pipe

400

-

-

... More
110mm dia - buried pipe

250

-

-

... More
200mm dia - Rain water pipe

400

-

-

... More
200mm dia - Rain water pipe - Buried pipe

210

-

-

... More
Supply and laying of DWC Structured Wall Polyethylene Piping Systems (Pipe with online/offline coupler and elastomeric sealing ring) with required specials non-smooth external annular corrugated and smooth internal surface (Double wall) (SN 8 Class) for non-pressure underground sewerage, drainage application generally as per IS-16098 (Part-2) type B.. (External) with required earthwork excavation, refilling the same to the required level and 100mm thick Msand at bottom of pipe etc.,complete in all respects and as directed by the departmental officers

-

-

-

... More
150mm dia

170

-

-

... More
200mm dia

400

-

-

... More
250mm dia

265

-

-

... More
300mm dia

330

-

-

... More
400mm dia

110

-

-

... More
Providing and fixing square mouth cast iron gully trap complete with RCC Chamber of M25 Grade 900 x 900 mm clear opening depth upto 2000mm i/c necessary excavation, foundation concrete 1:3:6 (1 cement : 3 fine sand : 6 graded stone aggregate 20 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design ricks of class designation 7.5.150 x 150 mm size “P” trap including 450 x 450 mm double seal C.I cover with frame. Note : Cost shall include excavation dewatering and watering proofing of chambers as directed at site

18

-

-

... More
Construction of inspection chamber (Rate Includes IC Cover )with 230mm thick best quality Table moulded bricks in CM 1:4 mixed with water proofing material over a bed of 150mm thick PCC 1:4:8, walls plastered smooth, both inside and outside with CM 1:3, including curing. Excavation in all types of soil, necessary wooden/steel form work, back filling of the chamber sides with the excavated soil, disposing of the surplus earth after back filling with initial lead of 30 meters. including ,lift, benching and channelling shall be finished smooth, in PCC 1:2:4 providing and fixing of 40 Ton SFRC manhole frame and cover ( Weight of frame and cover not less than 105 kgs) with Thermo plastic moulded steps as per specifications and drawings. Depth of chamber not exceeding 1200mm. Size: 600mm x 600mm (internal clear finished dimensions) as directed by the depatmental officers

-

-

-

... More
900 x 800 mm up to 900 mm deep

2

-

-

... More
900 x 1200 mm up to 2500 mm deep

13

-

-

... More
Constructing RCC Inspection Chamber of M25 Grade with Medium duty FRP cover 600mm x 600mm for sluice valve, i/c necessary excavation, foundation concrete 1:3:6 (1 cement : 3 fine sand : 6 graded stone aggregate 20 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design ricks of class designation 7.5

-

-

-

... More
DIA 1200 mm up to 2300 mm deep

9

-

-

... More
DIA 1500 mm above 2300 mm to 3000mm deep

3

-

-

... More
Construction of catch basin(Rate includes CB cover) with 230mm thick walls in well burnt table moulded bricks in CM 1:6 over a bed of 150mm thick PCC 1:4:8 internal walls shall be plastered smooth in CM 1:3 and external walls plastered CM 1:3 with sponge finish. Fixing CI frame and grating conforming to IS 5967 / 1970 The top surface of the catch basin grating shall be flushed to the landscape level and making suitable outlet arrangement to lateral drain with necessary excavation, back filling with the selected earth. with all leads and lifts etc., complete. Depth will vary.

-

-

-

... More
900 x 800 mm

35

-

-

... More
Supplying and laying of RCC Hume NP4 Class conforming to IS:458, with collars and jointing cement soaked Hessian cloth and finished smooth the joint with cement mortar 1:1, including Earth work excavation for the required depth with dewatering if required, laying pipe, providing and laying cement concrete 1:3:6, 75mm thick at the side of joints to the required line, level and slope and backfilling etc., complete (For Road Crossing)

-

-

-

... More
300 mm dia

35

-

-

... More
450 mm dia

375

-

-

... More
Supply, Installation, delivery, testing, commissioning of De-watering submersible pump made of Cast Iron Construction .Impeller shaft shall be S.S construction with mechanical seal suitable for building application. The unit shall include TEFC motor suitable for 415V,3Phase,50Hz & Insulation -Class F,IP 68 Protection and Base plates,Coupling,Nylon ropes for lifting pumps with Automatic ON/OFF Level Switch with common starter panel, each starter consists of suitable MPCB, Contactor, Overload relay, Single Phase Preventer, Push buttons, LED on indicators, all are in Weather Proof box (IP55) and necessary suitable copper cables from starter panel to pump (Appx.20Mtrs/each pump) etc. Pumps shall be IE-3 class rated. complete with necessary accessories. The panel shall have 2nos incomers with auto changeover switch. The panel shall be compatible with BMS (MODBUS RS 485 / MSTP) (For pump room)

-

-

-

... More
Drain water lifting pumps for PHE PUMP Room

1

-

-

... More
Each Pump capacity : 2 LPS

-

-

-

... More
No of Pumps : 1 working + 1 working

-

-

-

... More
Delivery head : 15 m

-

-

-

... More
Drain water lifting pumps for STP Room

1

-

-

... More
Each Pump capacity : 2 LPS

-

-

-

... More
No of Pumps : 1 working + 1 working

-

-

-

... More
Delivery head : 15 m

-

-

-

... More
Supplying, installing, testing, commissioning and Handing over of approved make Rain water filteration for Pressure sand filter of MS construction with Epoxy coating complete with necessary accessories like Frontal piping, valves, suitable supports for mounting, pressure gauge and orifice plate. The filter shall also include initial charge of under bed and multi – grade filter media to suite the requirement complete. Etc. as per the detailed specification for the efficient working of system. The inside of filter should have Food grade Neoprene rubber line of 4mm thick. The cost shall include the inter unit piping with necessary flanges, bolts, nuts, neoprene gaskets, welding wherever necessary, with necessary control valves, non return valves etc., and with one coat of primer and two coats of approved enamel paint etc., complete The maximum working Pressure shall be 3.5 Kg / Sqcm. Capacity : 16.25 Cum / hr

1

-

-

... More
a. Filter Feed Pumps - Horizontal, centrifugal Pumps Self priming type complete with motor, base plate, coupling etc with wetted parts, in CI - 2 Nos. (1W+1S) complete with panel and accessories and shall have dry run protection and weather proof enclosure : 16250Lph @ 15-20m head

-

-

-

... More
b. Hypo Dosing system of electromechanical type pf capacity 0-4 Lph, dosing pump, storage tank of as per suitable capacity

-

-

-

... More
c. Dual media Filter with a filtration rate of 16250LPH, Filter media, Multiport valve and with necessary accessories

-

-

-

... More
Design, engineering, and providing all equipment's, installation and commissioning of equipment's/electrical panel /piping for 150 KLD water treatment plant as description given in below: (8HRS. OPERATION)

1

-

-

... More
a. Filter Feed Pumps - Horizontal, centrifugal Pumps Self priming type complete with motor, base plate, coupling etc with wetted parts, in CI - 2 Nos. (1W+1S) complete with panel and accessories and shall have dry run protection and weather proof enclosure : 19000Lph @ 30-35m head

-

-

-

... More
b. Hypo Dosing system of electromechanical type pf capacity 0-4 Lph, dosing pump, storage tank of as per suitable capacity

-

-

-

... More
c. Supplying, installing, testing, commissioning and Handing over of approved make Pressure sand filter of MS construction with Epoxy coating complete with necessary accessories like Frontal piping, valves, suitable supports for mounting, pressure gauge and orifice plate. The filter shall also include initial charge of under bed and multi – grade filter media to suite the requirement complete. Etc. as per the detailed specification for the efficient working of system. The inside of filter should have Food grade Neoprene rubber line of 4mm thick. The cost shall include the inter unit piping with necessary flanges, bolts, nuts, neoprene gaskets, welding wherever necessary, with necessary control valves, non return valves etc., and with one coat of primer and two coats of approved enamel paint etc., complete The maximum working Pressure shall be 3.5 Kg / Sqcm. Capacity : 19 Cum / hr

-

-

-

... More
d. Supplying, installing, testing and commissioning and handing over of approved make Activated carbon filter of MS construction with Epoxy coating and initial charge and complete with all necessary accessories like Frontal piping, valves, suitable supports for mounting, pressure gauge and orifice plate etc. The filter should comply to all technical specifications for the efficient working of the system. The cost shall include the inter unit piping with necessary flanges, bolts, nuts, neoprene gaskets, welding wherever necessary, with necessary control valves, non return valves etc., and with one coat of primer and two coats of approved enamel paint etc., complete The maximum working Pressure shall be 3.5 Kg / Sqcm. Capacity : 19 Cum / hr.

-

-

-

... More
e. Hardness measuring Kit to measure the hardness of the treated water at the outlet of the filter with necessary connections as required

-

-

-

... More
Design, engineering, and providing all equipment's, installation and commissioning of equipment's/electrical panel /piping for 215 KLD MBR Sewage treatment plant including civil works as per drawing and as description given in below:

1

-

-

... More
Note :

-

-

-

... More
1. Pump capacity / head may vary and bidder to provide as per their design. Should be substantiated during detailed engineering

-

-

-

... More
2. Provision of pump sets can change as per bidders design and hydraulics

-

-

-

... More
3. Necessary lifting arrangement should be provided for submersible pumps and submersible Mixers.

-

-

-

... More
Supply, installation, testing and commissioning of following electro mechanical works and equipments -

-

-

-

... More
 S.S. 316 Manual coarse bar screen in screen chamber for peak flow- 10 mm opening  with suitable lifting arrangements complete as required.(1 no.)

-

-

-

... More
S.S. 316 Manual fine bar screen in screen chamber for peak flow- 6 mm opening  with suitable lifting arrangements complete as required. (1 no.)

-

-

-

... More
Providing & fixing of  MSEP slotted pipe oil skimmer of suitable capacity .Slotted pipe type with necessary arrangements in Oil & Grease Trap. (1 No.)

-

-

-

... More
Equalised Sewage Transfer pumps of 3 Nos. (2W +1S) of duty 6 Cum/Hr @ 15 m head, vertical  submersible pumps with casing/cover of Cast Iron(CI), impeller SS and shaft of SS, suitable for mechanical packed seal complete with base frame, pump driven by electric motor of suitable kW rating and RPM with IP 55 protection and class F insulation, foundation bolts, alongwith lifting arrangement etc. From Equalisation Tank to Fine screen prior to Anoxic tank (Cutter type Pumps) Solid handling capacity shall be 20 mm. (3 Nos.)

-

-

-

... More
Equalised  Sewage Bypass pumps of 2 Nos. (1W +1S) of duty 13 Cum/Hr @ 35 m (approx.) head, vertical  submersible pumps with casing/cover of Cast Iron(CI), impeller SS and shaft of SS, suitable for mechanical packed seal complete with base frame, pump driven by electric motor of suitable kW rating and RPM with IP 55 protection and class F insulation, foundation bolts, etc.  alongwith lifting arrangement etc. From Equalisation Tank to nearest sewer drain during festive season only (Cutter type Pumps) Solid handling capacity shall be 20 mm. (3 Nos.)

-

-

-

... More
Twin lobe type rotary air blowers for Equalisation Tank & Sludge Holding Tank with suitable capacity  with suction & delivery silencer, & all other necessary accessories, gauges etc. - Driven through "V" belt or directly coupled through flexible coupling to a TEFC motor  suitable for 415 + 10% volts, 3 phase, 50 cycles A/C supply, coarse bubble air grid, complete with valves & air distribution grid complete with Acoustic Hood as required. Qty : 2 nos (1W+1S)  

-

-

-

... More
Air supply rate - 0.9 m3 of air per m3 of Volume of the tanks. Common Air blowers shall be used to supply compressed air in Equalisation tank and Sludge Holding tank. 

-

-

-

... More
Coarse bubble air grid for Equalisation tank and Sludge Holding tank ,MOC- UPVC (1 Lot)

-

-

-

... More
Drum Screen prior to Anoxic Tank - 2 mm Punched Hole MOC : Body CS Drum : SS 304 (2 Nos.)

-

-

-

... More
Providing Submersible Mixers and its associated accessories and lifting arrangements etc. all complete in all respect. For Anoxic Tank. MOC : SS 304

-

-

-

... More
Twin lobe type rotary air blowers (VFD Driven) for Aeration Tank As per design (Approximately 100-120 Nm3/hr) with suitable capacity  with suction & delivery silencer, & all other necessary accessories, gauges etc. - Driven through "V" belt or directly coupled through flexible coupling to a TEFC motor of suitable kW Suitable for 415 + 10% volts, 3 phase, 50 cycles A/C, supply of fine bubble membrane type diffusers complete with valves & air distribution grid complete with Acoustic Hood as required. Qty : 3 Nos. (2W +1S).

-

-

-

... More
Non clog type retrievable air  diffuser system tubular type capable of   handling desired flow of air. Air diffuser  grid  shall   be assembled in modular form  so that  they can  be  replaced/ repaired easily from platform at the top. Air  diffuser system shall be provided with fine  air bubble type diffusers for Aeration tank as per Bidders design. MOC- EPDM

-

-

-

... More
Air flow rate per diffuser- 8 m3/hr per diffuser. (1 Lot.)

-

-

-

... More
Nitrifying liquor transfer  pumps of 3 nos. (2W +1S) of duty of suitable capacity Min. 24 m3/hr and 12 m head , horizontal  centrifugal pumps with casing/cover of Cast Iron(CI), impeller SS and shaft of SS, suitable for mechanical packed seal complete with base frame, pump driven by electric motor of suitable kW rating and RPM with IP 55 protection and class F insulation, foundation bolts,. Transferring mix liquor from MBR tank to Anoxic tank.

-

-

-

... More
Providing MBR modules (for 22 hrs operation) submerged type housed in cabinet with membrane add on provision, to handle sewage of 250 KLD flow transmitter, turbidity analyser,automatic cleaning and recovery systems for the membrane, of  Immersed hollow fiber, ultra filtration membrane with SS skid for housing the membranes alongwith Membrane Module Lifting Arrangements. Maximum Flux Permitted : 25 LMH

-

-

-

... More
Membrane MOC : PVDF Braket MOC : SS

-

-

-

... More
Membrane Lifting Arrangements : Monorail and electric hoist with electric travelling trolley of suitable capacity equivalent to 1.5 times the load of equipment to be lifted

-

-

-

... More
Providing twin lobe type rotary air blowers (VFD Driven) for MBR Tank As per design with suitable capacity  with suction & delivery silencer, & all other necessary accessories, gauges etc. - Driven through "V" belt or directly coupled through flexible coupling to a TEFC motor of suitable kW Suitable for 415 + 10% volts, 3 phase, 50 cycles A/C, supply of fine bubble membrane type diffusers complete with valves & air distribution grid complete with Acoustic Hood as required. Qty : 3 Nos. (2W +1S).                   

-

-

-

... More
SPECS FOR ACOUTIC HOOD  - For Air Blowers supplying air to Equalisation Tank & Sludge Holding Tank, Aeration Tank and MBR Tank -Supplying acoustical hood for each blowers in STP. Hood shall be made out of 16G GI sheet with 50mm thick open cell nitrile rubber of density 140-180 kg/cum. Care shall be taken for heat dissipation of motor while enclosed on hood. Openings in hood for piping shall be acoustically closed with fibre glass and silicon sealant etc. all complete in all respect as directed by manufacturer and site in charge.

-

-

-

... More
MBR Permeate pumps (VFD Driven) - 3 Nos. (2W +1S) of duty 6-8 Cum/Hr @ 10 m head, horizontal centrifugal pumps  with casing/cover of Cast Iron(CI), impeller SS and shaft of SS, suitable for mechanical packed seal complete with base frame, pump driven by electric motor of suitable kW rating and RPM with IP 55 protection and class F insulation, foundation bolts, etc. From MBR Tank to MBR Permeate tank and Irrigation tank (For Blending)

-

-

-

... More
Backpulse pumps (VFD Driven) - 3 Nos. (2W +1S) of Suitable capacity - As per Membrane Manufacturer's deign - horizontal centrifugal pumps  with casing/cover of Cast Iron(CI), impeller SS and shaft of SS, suitable for mechanical packed seal complete with base frame, pump driven by electric motor of suitable kW rating and RPM with IP 55 protection and class F insulation, foundation bolts, etc. for Membrane Cleaning

-

-

-

... More
The cost including CTBD Effluent Treatment,RO system as per technical specification and Hypochlorite  Dosing System for Disinfection of Treated Sewage and CTBD Effluent

-

-

-

... More
NaOCl dosing Pumps MOC : PP - 2 Nos. (1 W+1S) pumps with 1 no. HDPE dosing tank of suitable capacity. (1 Set)

-

-

-

... More
Hypochlorite  Dosing System for CIP of Membrane System

-

-

-

... More
NaOCl dosing Pumps MOC : PP - 2 Nos. (1 W+1S) pumps with 1 no. HDPE dosing tank of suitable capacity. (1 Set)

-

-

-

... More
Citric Acid Dosing system along with agitator for CIP of Membrane System

-

-

-

... More
NaOCl dosing Pumps MOC : PP - 2 Nos. (1 W+1S) pumps with 1 no. HDPE dosing tank of suitable capacity with Agitator MOC- SS 304. (1 Set)

-

-

-

... More
Centrifuges shall produce a dewatered sludge cake of no less than 20% dewatered solids. At least 95- 98% of the solids shall be captured in the dewatered cake and less than 2% of the solids shall be in the centrate.

-

-

-

... More
Dewatering Polyelectrolyte (DWPE) Dosing System 

-

-

-

... More
For Poly dosing 2 nos. Dosing pump MOC : PP -(1W+1S) with 1 No. HDPE Tank of suitable capacity with SS Mixer

-

-

-

... More
Dosage : 1.5-2.5 kg / ton of dry solids @ 0.1% solution strength

-

-

-

... More
PIPING

-

-

-

... More
Providing and fixing all piping (as described below) and isolation control Ball / butterfly valves (Min. PN 10) of required sizes and numbers with all accessories, fittings, supports, clamps, double flanged flexicon rubber expansion joint with rubber gasket as per system pressure, nuts, bolts, washers, fasteners, puddle flanges for all tanks, other flanges, all required type of valves such as NRV's, flow control valves, sampling valves, flow measurement device, butterfly valves, ball valves, globe valves etc., SS 304 screen strainers Y type at suction of clear water pumps, for making the system complete in all respects with anti corrosive protection. Details are as follows:

-

-

-

... More
Butterfly Valve : Cast Iron Wafer type butterfly valves  (PN 10) as per IS:13095, with SS disc, SS shaft, SS seating rings, SS internal fastening,  EPDM seat, CS external nuts-bolts.

-

-

-

... More
Check Valve : Cast Iron body  dual plate wafer type check valve (NRV) (PN 10) with SS disc, SS stem,  EPDM seat, spring & pin, SS stem, SS internal fastening, CS external fastening.

-

-

-

... More
PVC Flexible Breaded Hose Pipe : Submerged piping for raw sewage transfer pumps / Submerged piping for diffusers.

-

-

-

... More
Interconnecting pipes with required pipe fittings, control valves, manual valves as per the system design, flange connections, gaskets,GI fasteners, pipe supports etc for making the system completed.

-

-

-

... More
MSEP : All interconnecting piping & Frontal Piping for filters

-

-

-

... More
CI for Pump suction and  discharge

-

-

-

... More
UF System : UPVC

-

-

-

... More
RO High pressure piping - SS 316 with Victaulic coupling

-

-

-

... More
Low pressure piping - uPVC

-

-

-

... More
GI (Class 'C') : Air grid piping-non submerged & UPVC for submerged Piping

-

-

-

... More
INSTRUMENTS

-

-

-

... More
Capacitance type Level Transmitters in Equalisation Tank, MBR Tank, MBR Permeate Tank, CTBD effluent collection Tank, UF Feed Tank, UF Permeate Tank/RO Feed Tank, RO permeate Tank, RO reject tank with provision for alarm at high level in the tank and alarm as well as tripping of pumps at low level.

-

-

-

... More
Level switches in Sludge Holding Tank, Plant Room, Sump, Centrate collection Sump, Pump room all Dosing Tanks with provision for alarm at high level in the tank and alarm as well as tripping of pumps at low level.

-

-

-

... More
DO meter in Aeration tanks

-

-

-

... More
Electro- magnetic Flow transmitter with indicator and totalizer

-

-

-

... More
‒ At the discharge of Equalized sewage transfer Pumps

-

-

-

... More
‒ At the discharge of Equalized sewage Bypass Pumps

-

-

-

... More
‒ At the discharge of MBR Permeate Pumps

-

-

-

... More
‒ At the discharge of MBR Backpulse Pumps

-

-

-

... More
‒ Any location wherever necessary as per bidder’s design

-

-

-

... More
Pressure Transmitter at the discharge Backpulse Pumps

-

-

-

... More
DPS across bag filter, Cartridge Filter, RO system

-

-

-

... More
Pressure switch at the suction & Discharge of RO High Pressure Pump

-

-

-

... More
Turbidity meter on the discharge pipe of MBR Permeate Pumps and UF permeate pumps

-

-

-

... More
Flow Transmitter on RO Reject Line

-

-

-

... More
pH Transmitter at discharge of RO Inlet and RO Permeate Line

-

-

-

... More
Conductivity Transmitter at RO Inlet and Permeate Line

-

-

-

... More
ORP analyser with transmitter and controller

-

-

-

... More
Dump valve & Auto valve for RO system

-

-

-

... More
Pressure gauges

-

-

-

... More
If required, Instrument air compressor with an air receiver tank, air filter-dryer and air filter regulator along with instrument air piping and tubing for pneumatically operated valves

-

-

-

... More
PLC PANEL

-

-

-

... More
Providing Complete instrumentation system including PLC for   Automatic Operation. Vendor Should provide PLC Logic as required to operate their System. PLC controller with SCADA software system should be integrated with BMS through Open protocol including all necessary accessories, material ,tools takcles required to complete the job in all respects alongwith UPS. BMS compatible with any open communication protocol for 3rd party integration.

-

-

-

... More
Supply, installation, testing and commissioning of following electro mechanical works and equipments -

-

-

-

... More
ELECTRICAL INSTALLATION FOR SEWAGE TREATMENT PLANT SYSTEM

-

-

-

... More
LT Panel for Sewage Treatment Plant

-

-

-

... More
Design, Engineering, Manufacture, Supply, Commissioning, Documentation of  LT Switchgears for STP area as per the scope of work  including submission of relevant data, inspection and testing at factory works, packing, transportation from MANUFACTURER works to site, including transportation from store/yard to site at the place of installation, handling equipment , unpacking, assembly, including mounting and wiring of loose parts supplied by equipment vendor, interconnection of shipping sections and requisite inter-panel wiring between shipping sections, including supply of wiring material, installation on foundations or fixing to wall or steel structures, aligning, levelling, grouting, testing, and calibration of relays and metres etc., including all labour and materials, as per approved drawings, specification  of this tender and directions of PMC/Employer  The panel incommer shall not exceed the 400A of MCCB & 25 numbers of outgoing including spare feeder.

-

-

-

-

-

-

... More
Supply, Installation testing & commissioning of local push button with all necessary accessories including all labour and materials required for STP system as per approved drawings, specification  of this tender and directions of PMC/Employer

-

-

-

... More
LT Power & Control Cable

-

-

-

... More
Supply, laying,testing and commissioning of power,control & communication cables along with cable tray and supports of required size for STP System  as per the scope of work.

-

-

-

... More
Cables shall be laid in  cable trays, hume pipe/cable Gallery supported on structure/pull through pipes  including pipes, supply and fixing of Aluminium strip number tags, supply and fixing of GI saddles and saddle bars, supports including anchor fastener,conduits etc. including transportation from owners stores to site. Unpacking, with all labour and material as per specification of this tender and directions of PMC/Employer. (Suitable size of IC/OG cables shall be selected by the Electrical contractor as per Load details.)

-

-

-

... More
Earthing System

-

-

-

... More
Supply, installation and connection of required size of earthing strip required for STP area as per the scope of work including welding at joints, providing anti-corrosive paint or bitumen for welded portion, clamping and necessary hardware for connecting, etc., including all labour and materials,as per specification of this tender and directions of PMC/Employer  (Earthing will be Pipe earthing with 3000mm depth &40 mm Dia pipe, Strip size will be decide as per the fault level calculation.)

-

-

-

... More
Supply and laying of 1000mm wide safety insulation mats of 415V,required for HVAC system  grades required for maintenance of electrical equipment in substation, including cutting to required shape as per IS

-

-

-

... More
ADDITIONAL ITEMS /OTHER WORKS / SYSTEM

-

-

-

... More
Any other items, works, systems not specifically mentioned above but necessary for satisfactory performance of the system the above cost including of all kind of civil works for plant room, treated water sump of minimum capacity 110KL as per the design drawing and the collection sump of 110KL capacity below the last chamber invert level for STP SRC cement used for constuction purpose & steel must be treated with epoxy coated.

-

-

-

... More
Miscellaneous Items

-

-

-

... More
Sewage parameter:

-

-

-

... More
Inlet:

-

-

-

... More
PH = 6.5 - 8.5

-

-

-

... More
TSS (mg/l/) = 150

-

-

-

... More
BOD (mg/l/) = 600

-

-

-

... More
Total nitrogen (mg/l/) = 50

-

-

-

... More
Oil & grease (mg/l/) = 10

-

-

-

... More
Total coliform = 10000

-

-

-

... More
Outlet:

-

-

-

... More
PH = 6.5 - 8.5

-

-

-

... More
TSS (mg/l/) = 20

-

-

-

... More
BOD (mg/l/) = 10

-

-

-

... More
COD (mg/l/) = 50

-

-

-

... More
Total nitrogen (mg/l/) = 10

-

-

-

... More
Oil & grease (mg/l/) = Nil

-

-

-

... More
Total coliform = 100

-

-

-

... More
Supply, delivery, testing, commissioning of Vertical Multi stage Centrifugal Pump with suitable capacity 415V, 3-phase,50Hz motor and coupling with base frame having discharge capacity of 10 Cum/Hr against total head of 25m from all causes, with common starter panel, each starter consists of suitable MPCB, Contactor, Overload relay, Single Phase Preventer, Push buttons, LED on indicators, all are in Weather Proof box (IP55) and necessary suitable copper cables from starter panel to pump (Appx.20Mtrs/each pump) etc. Pumps shall be IE-3 class rated. complete with necessary accessories. The panel shall have 2nos incomers with auto changeover switch. The panel shall be compatible with BMS (MODBUS RS 485 / MSTP) Scope included auto level controller and cable between sump and OHT.

-

-

-

... More
For Domestic water Lifting from sump to OHT

1

-

-

... More
Each Pump capacity : 5 LPS

-

-

-

... More
No of Pumps : 2 working + 1 working

-

-

-

... More
Delivery head : 60-65 m

-

-

-

... More
For Flush water Lifting from sump to OHT

1

-

-

... More
Each Pump capacity : 4 LPS

-

-

-

... More
No of Pumps : 2 working + 1 working

-

-

-

... More
Delivery head : 60-65 m

-

-

-

... More
For Flush water Lifting from sump to Gardening

1

-

-

... More
Each Pump capacity : 3 LPS

-

-

-

... More
No of Pumps : 1 working + 1 working

-

-

-

... More
Delivery head : 25-30 m

-

-

-

... More
For Flush water Lifting from sump to HVAC mackup tank

1

-

-

... More
Each Pump capacity : 5 LPS

-

-

-

... More
No of Pumps : 1 working + 1 working

-

-

-

... More
Delivery head : 60-65 m

-

-

-

... More
OHT & UG SUMP Transfer Pumping System

-

-

-

... More
Automatic Level Control System for the OHTs and UG SUMP.

-

-

-

... More
Supply, Installation, Testing, Commissioning and handing over of automatic tank level controller comprising of the following:Level Control with Motorised valves comprising of following:

-

-

-

... More
Magnetic ball float type Level sensor for tank - High Level & Low level - 1 set. Audco / Kitz / Belimo make valve actuator, suitable for the following ball / butterfly valve. The mechanism shall be of tight shut-off type. - 1 set. Audco / Kitz / Saunders make butterfly / ball valve, with suitable adaptor for the above valve actutaor - 1 no. Wiring with 2C x 2.5 sqmm copper wires in 20-mm GI conduits interconnecting the level sensor and the valve actuator - Assume 20 RMT. Power transformer, if necessary for supplying power to the valve actuator from field available power supply of 230V, 1Ph., 50hz, complete with powder coated, weather proof mounting box, incoming 5A MCB, etc., complete.- 1 set.

-

-

-

... More
For Domestic , Flush ,HVAC MAKEUP Water OHTs & UG SUMP:

-

-

-

... More
a) With 40mm butterfly valve - Domestic & Flush

8

-

-

... More
b) With 50mm butterfly valve - HVAC mackup

1

-

-

... More
Supply, Installation, of Manhole cover 60 X 60 cm Heavy grade with frame (For UG sump & OHT)

34

-

-

... More
Supplying, installing, testing, commissioning and Handing over of approved make RO plant 16KLD

1

-

-

... More
FILTER FEED WATER PUMPS:

-

-

-

... More
Supplying, installing, testing and commissioning of 2 Nos. of transfer pumps (one working + one stand by) for pumping the water from treated water Tank (OHT). The pump shall be coupled to adequate H.P. electrical motor, mounted on a common base frame made out of 'GI' with necessary bolts, nuts,saddle and mesh.. 3cum/hr

-

-

-

... More
Suitable indoor wall mounting type control panel with auto / manual change - over switch including dry run protection arrangement, wiring upto panel, earthing etc. complete.

-

-

-

... More
1 no. pressure gauge 4" dial with needle valve and tee fittings.

-

-

-

... More
2 nos. of UPVC ball valve SCH 40/80 Rating suitable on Suction side.

-

-

-

... More
2 nos. of UPVC ball valve SCH 40/80 Rating suitable on delivery side.

-

-

-

... More
UPVC manifold of suitable dia on Suction & delivery side finished neatly with flanged end on either sides and collar provision for connectivity of above mentioned valves.

-

-

-

... More
MICRON CARTRIDGE FILTER

-

-

-

... More
Supply, installation, testing and commissioning of Micron Cartridge Filter for removal of finer suspended particles in the water. The micron cartridge filter shall be suitable for following requirements / specifications.

-

-

-

... More
Maximum pressure drop across the unit - 0.5 kg / sq.cm

-

-

-

... More
Silt Density Index (SDI) -- less than 5

-

-

-

... More
Micron cartridge filter shall be provided with pressure guage with needle valve 2 nos. (1 on the inlet and 1 on the out let)

-

-

-

... More
HIGH PRESSURE PUMP

-

-

-

... More
Supplying, installing, testing and commissioning of 1 no. vertical type Monobloc in - line High pressure pumps for pumping the water to RO membrane assembly. The pump shall be coupled to the adequate H.P. electrical motor and shall be mounted on a common base frame with SS manifold.

-

-

-

... More
MOC - CI / SS 304

-

-

-

... More
(However, the actual head to be selected by the vendor as per system design requirement and as per "IMS Design" analysis)

-

-

-

... More
The rate quoted shall be inclusive of:

-

-

-

... More
1 no. pressure gauge 4" dial with needle valve and tee fittings.

-

-

-

... More
1 no. of ball valve of brass body nickel plated with stainless steel ball, lever operated (RB/TBS / Cimbrio make) and tested to 20 kg / sq.cm.on Suction side.

-

-

-

... More
1 no. of ball valve of brass body nickel plated with stainless steel ball, lever operated (RB/TBS / Cimbrio make) and tested to 20 kg / sq.cm.on Delivery side.

-

-

-

... More
SS manifold of suitable dia on delivery side with flanged end on either sides and collar provision for connectivity of above mentioned valves.

-

-

-

... More
RO MEMBRANE & PRESSURE VESSEL

-

-

-

... More
Supplying, installing and commissioning of the RO membrane assembly unit with necessary manifold, supporting system, clamps, brackets, interconnecting piping, valves, pressure guages etc., with backish water membrane (filmtec / Hydranautics make) for removal of TDS in the borewell water. (The TDS in raw borewell water is around 2000 PPM and hardness is around 600 PPM). The RO membrane assembly shall be as per the following requirement and specification (However the actual requirement of membrane as per the system design / demand shall be verified by the vendor with respect to "ROSA" Analysis)

-

-

-

... More
Type of Membrane: Brackish

-

-

-

... More
Size of membrane:

-

-

-

... More
No. of pressure vessel / tube - 1 Element

-

-

-

... More
No. of elements in one vessel / tube

-

-

-

... More
Total qty of membrane

-

-

-

... More
Type of pressure vessel / tube - PVC Pipe ( 6 kg - 10 kg/ sq.cm)

-

-

-

... More
RO SKID

-

-

-

... More
Supplying, installing, testing and commissioning of SS 304 SKID with required supports and accessories of Reverse Osmosis Unit. The SS 304 skid should enclose the following:

-

-

-

... More
RO membranes of Total no of Membranes mentioned above

-

-

-

... More
SS 304 Pipe lines for Complete High Pressure lines

-

-

-

... More
UPVC Pipe lines for Complete Low Pressure lines

-

-

-

... More
Two numbers of 4" Dial Glycerin filled Pr.Gauge at RO Feed & RO Reject line of 21 kg/cm2 Pr.rating.

-

-

-

... More
One number of Flowmeter / Rotometer at RO Feed, RO Reject & RO product line

-

-

-

... More
Low pr.switch & High pr.switch at Inlet and outlet

-

-

-

... More
One number of Brine control valve, By pass valve, Chemical cleaning valve at inlet and outlet, required bolts and nuts etc.,

-

-

-

... More
ULTRAVIOLET STERILIZER

-

-

-

... More
Supply, installation, testing and commissioning of the ultraviolet sterilizer suitable for flow rate of 3cu.m / hr. The unit shall be suitable for removing the bacteria in RO Permeate water.

-

-

-

... More
The unit shall comply with the following technical specifications.

-

-

-

... More
The quartz sleeve protection for UV lamp.

-

-

-

... More
Unit shall be suitable for a working pressure of 5 sq.cm

-

-

-

... More
Mounting brackets to be provided.

-

-

-

... More
Suitable for 220V single phase power supply operation.

-

-

-

... More
Stainless steel type 304 electropolished purification chamber.

-

-

-

... More
Single port providing visual indication of lamp.

-

-

-

... More
High instensity UV lamps rated for min of 7500 hours continuous use

-

-

-

... More
MEMBRANE CLEANING SOLUTION TANK

-

-

-

... More
Supply erecting, testing and commissioning of circular double layered HDPE Chemical Cleaning Tank of capacity as mentioned below.Tank with Top Lid.

-

-

-

... More
Storage tank of capacity 200 litres

-

-

-

... More
RO MEMBRANE CLEANING SYSTEM PUMP

-

-

-

... More
Supplying, installing, testing and commissioning of 1 No. of Monobloc type RO membrane cleaning system pumps (One working) for pumping the primary treated water through Micron cartridge filter, high pressure pump.The pump shall be coupled to the adequate H.P. electrical motor and shall be mounted on a common base frame with mani fold.

-

-

-

... More
MOC - SS 316 (Complete parts in SS 316)

-

-

-

... More
The rate quoted shall be inclusive of:

-

-

-

... More
1 no. pressure gauge 4" dial with needle valve and tee fittings.

-

-

-

... More
1 no. of UPVC ball valve SCH 40/80 Rating suitable on Suction side.

-

-

-

... More
1 no. of UPVC ball valve SCH 40/80 Rating suitable on delivery side.

-

-

-

... More
Alarm indication with signal in the event of pump failure etc.

-

-

-

... More
UPVC manifold of suitable dia on delivery side and suction side for connectivity of above mentioned valves.

-

-

-

... More
MCC PANEL

-

-

-

... More
Supply, fabrication, erection, testing and commissioning of control panel (CP) . The panel shall be of "non comparmentalised" for RO Feed Pump, High Pressure Pump & Dosing Pumps. The Panel shall be sheet steel fabricated, finished with powder coating of approved color, and of floor mounted, free standing cubicle type with incoming MCC TP and N bus bars and outgoing with fuse switch units, starter relays, over load,he panel shall have Voltmeter, Ammeter and indicating lamps on the incoming side only indicating lamps for the pumps on outgoing side to indicate the operation mode. The panel shall be complete in all respectsand prior to the supply, fabrication drawing shall be submitted for consultants approval.

-

-

-

... More
The rate quoted shall be inclusive of the following:

-

-

-

... More
Earthing for panels .

-

-

-

... More
Dry run protection arrangement for the following :

-

-

-

... More
RO Feed Pump

-

-

-

... More
High Pressure pump

-

-

-

... More
Dosing pump

-

-

-

... More
Chemical cleaning pump

-

-

-

... More
Audio/visual alarm indication in the event of malfuntioning of RO Plant

-

-

-

... More
RO STORAGE TANK

-

-

-

... More
Storage tank of capacity 16000 litres

-

-

-

... More
Internal & External Electrical arrangements

-

-

-

... More
HT PANEL & YARD WORKS

-

-

-

... More
33 KV Ring Main Gear (RMG) -OutdoorType Design, Manufacture, Assembly, Inspection and Testing before supply, Packing and delivery at Site, erection, Installation, Testing & commissioning of 33KV HT switchgear with all accessories and suitable for installation in three phase, three wire, 33kV,50Hz, A.C.distribution network, complete with all accessories erected in the provided foundation complete as per specfication and standards as directed by PMC/Employer in charge at Site. Outdoor Type Panel 33kV HT Ring Main Gear Comprising of Incomer : 2nos 800A ,26.3 KA, 3sec rating Horizontal Draw out type VCB including metering arrangements (AS PER TANGEDCO NORMS). Outgoings : 1no of 800A, 26.3 KA, 3sec rating Horizontal Draw out type VCB as outgoing including metering arrangements (AS PER TANGEDCO NORMS). Busbars: 33KV,800A,TP,50Hz,26.3 KA, Copper. Busbars MAKES: (SYSTEM CONTROLS / MEGAWIN / SCHNEIDER)

1

-

-

... More
The panel shall be provided with necessary protections, Measuring Instruments, Indicating Instruments, Protection Relays, CTs, PT with necessary control fuses/MCBs,Terminal Blocks,SPD, Earthing, Sign writing and Base channels etc., with complete all accessories as required for satisfactory operations and as per the detailed SIngle line Diagram and Technical specifications, Data sheets and as per TANGEDCO Requirements. The panel suitable for outdoor mounting & terminating of 300 sq.mm. 3 core HT XLPE 33KV as incoming and outgoing, Terminal Blocks, Earthing,Powder coated painting and Base channels etc., with complete all accessories as required for satisfactory operations as directed and approved by PMC/Employer in charge. Inbuilt battery backup needs to be considered. RMG yard Fencing and Foundation related items are covered under relveant items.HT panel yard Fencing and Foundation related items are covered under relveant items. Note: Metering and Protection should be supplied as per TANGEDCO Requirements and Vendor should procure the RMG as per latest amendement from TANGEDCO, no additional payment shall be provided from client.

-

-

-

... More
33 kV HT Panel - Four (4) VCB Panel - Indoor Type Design, Manufacture, Assembly, Inspection and Testing before supply, Packing and delivery at Site, erection, Installation, Testing & commissioning of 33KV HT switchgear with all accessories and suitable for installation in three phase, three wire, 33kV, 50Hz, A.C.distribution network, complete with all accessories erected in the provided foundation complete as per specfication and standards as directed by PMC/Employer in charge at Site. Indoor Type 33kV HT Panel-2 with Comprising of Incomer : 1no 800A ,26.3 KA, 3sec rating Horizontal Draw out type VCB including metering arrangements Outgoings : 3nos of 800A, 26.3 KA, 3sec rating Horizontal Draw out type VCB as outgoing including metering arrangements Busbars: 33KV,800A,TP,50Hz,26.3 KA, Copper. Busbars MAKES: (SYSTEM CONTROLS / MEGAWIN / SCHNEIDER)

1

-

-

... More
The panel shall be provided with necessary protections, Measuring Instruments, Indicating Instruments, Protection Relays, CTs, PT with necessary control fuses/MCBs,Terminal Blocks,SPD, Earthing, Sign writing and Base channels etc., with complete all accessories as required for satisfactory operations and as per the detailed SIngle line Diagram and Technical specifications, Data sheets.. The panel suitable for indoor mounting with Internal Arc & terminating of 300 sq.mm. 3 core HT XLPE 33KV as incoming and outgoing, Terminal Blocks, Earthing,Powder coated painting and Base channels etc., with complete all accessories as required for satisfactory operations as directed and approved by PMC/Employer in charge. Inbuilt battery backup needs to be considered.

-

-

-

... More
Supply & erection of GI. gate of size 1000mm wide & 2100mm height with all accessories,earthing of gates with braided copper including necessary civil works as required as per site condition. The Gate shall be painted with 2 coats of anticorrosive primer & 2 coats of Aluminiun enamel paint. (At RMG HT panel area & Transformer Yard)

4

-

-

... More
Supply & providing of M10 Concrete in the RMG & HT panel -1 yard as per the site conditions. The Rate shall include cleaning & levelling of the yard as required at the site. (At RMG & HT panel-1 area)

45

-

-

... More
Supply & fixing of chain link fencing of height 2meter With all supports necessary clamps,fasteners,binding wires,earthing of fencing at all sides with suitable GI wires including all accessories as required as per site condition. (At RMG & HT panel-1 area)

28

-

-

... More
Charges towards digging, excavation of normal soil to a depth of 1200mm x 600mm width and refilling the same after completion of works.

25

-

-

... More
Supply & fixing of manhole chamber sizes of 1000mm x 1000mm & including necessary four side brick required.

1

-

-

... More
TRANSFORMER

-

-

-

... More
Supply, unloading, handling, safe keeping, Installation, testing and commissioning of 2500kVA, 33KV/433V, DYN11 Outdoor, ONAN type transformer with OLTC & RTCC panel. The tapping on HV for HV variation shall be of (+5)% to (-15)% in step of 1.25% by OLTC. Necssary phase and neutral CTs, control switches and transformer Protection relays should be provided at each Transformer such as Transformer Buchholz relay, OLTC surge relay, Oil temperature relay, winding temperature relay, magnetic oil level gauge and pressure relief valve with NO/NC, Auxiliary relays as per standards. The transformer should be complied Energy efficiency Level-2 as per IS-1180. The primary and secondary winding material shall be of copper. All hardware shall be hot dipped galvanised. The copper flexible strip shall be provided at every gasketted joint for earthing continuity purpose. The Transformer shall be provided with cable termination box on primary side to terminate 3C 300Sqmm XLPE Al. Ar. 33kV HT cable and on secondary side with 4000A Sandwich type aluminium busduct with all accessories as per the detailed specification and drawing enclosed.

2

-

-

... More
HT CABLES

-

-

-

... More
Supply, Laying, Testing & commissioning of 300 sq.mm. 3 core HT XLPE 33KV (E), XLPE Aluminium armoured cable laid in underground upto 1200mm deep / existing concrete trenches / cable trays/ hume pipe , including excavation of trench & minor civil works,covering of exposed portion as per Engineer-in-Charge. recommendation etc. including transportation from stores to site. Unpacking, with all labour and material as per specifications.

80

-

-

... More
Supply, Installation, Testing & commissioning of outdoor cable end termination with heat shrinkable joining kit with all accessories including lugs suitable for 300 sq.mm. 3 core HT Cable Outdoor Terminations XLPE 33KV (E) etc, complete as directed by ENgineer in charge.

2

-

-

... More
Supply, Installation, Testing & commissioning of indoor cable end termination with heat shrinkable joining kit with all accessories including lugs suitable for 300 sq.mm. 3 core HT Cable Indoor Terminations XLPE 33KV (E) etc, complete as directed by ENgineer in charge.

8

-

-

... More
Supply, Installation, Testing & commissioning of indoor cable Staright through joining kit with all accessories including lugs suitable for 300 sq.mm 3 core HT Cable Straight Thorugh Joints 33KV (E) Screened XLPE Cables etc, complete as directed by Engineer in charge.

1

-

-

... More
LT PANEL

-

-

-

... More
MAIN POWER CONTROL CENTER (TTA Panel) with AUTOMATIC FIRE DETECTION AND SUPPRESSION SYSTEM WITH Novec 1230/ FK5-1-12 GAS & Complete

1

-

-

... More
Design, Supply, Installation Testing & Commissioning of Main Power Control Center consist of Length - 21Mtr X 1.5Mtr Deepth X 2.2Mtr Height) suitable for 415Volts 3Phase 4wire system, fabricated from CRCA sheet steel (Doors:2mm Body:2mm Gland:3mm covers and partitions:1.6mm,) single fronted, free standing, front hinged, rear removable, extendable on both sides, dust & vermin proof, cubicle type, floor mounted, undrilled gland plates at top / bottom, complete with internal wiring, ferrules, name plates, painting etc., conforming to the technical specification for panels & comprising of the following. (Refer enclosed SLD) Tinned Copper Busbar with heat shirnkable colour coded sleeve with SMC Bus bar supports Busbar Phase: 3R X 125 X 10mm Neutral : 3R X 125 X 10mm Panel should be fully comply to IEC 61439 part 1 & 2 of type tested assembly (TTA) in addtion to the internal arc test and tempeture rise test at multiple point with necssary test certificate to be submit

-

-

-

... More
Section - A

-

-

-

... More
Incomer - 1 : EB

-

-

-

... More
1 Nos - 4000A, 4P, 65kA Drawout type, motor operated ACB with Microprocessor based releases (with Over current / Earth fault / Short circuit ) & Trip & close Coil with Under Voltage releases, high speed closing feature with earthing, door interlock, automatic safety shutters to shroud the bus bar side and FRP sheet barrier on the incoming & outgoing cable sides of the circuit breaker. (Electrical & mechanical Interlock)

-

-

-

... More
Metering for Each Incomer:

-

-

-

... More
1No - Load Manager with RS485 Interface with Maxmimum Demand Indication + controller

-

-

-

... More
1Sets - Dual Core Cast Resin CTs of ratio 4000/5A, Class 0.5 for metering and class 5P10 for Protection. The CT burden shall be 10VA.

-

-

-

... More
1set - 4000/5A, Cl:0.5 for metering. The CT burden shall be 10VA.Resin cast CT's for APFCR. Except DG incomer

-

-

-

... More
1No - Undervoltage relay with time delay & Earth fault Relay

-

-

-

... More
2 Sets - 63A 4P MCB

-

-

-

... More
1set - RYB LED type indication lamps for Phase

-

-

-

... More
1set - RGA LED type indication lamps for ON/OFF/Trip

-

-

-

... More
1Set - Control MCB with Neutral link

-

-

-

... More
1set - class B(125KA) 3 Numbers of lightning arrester for the connection between Phase and Neutral and one number of lightning arrester between Neutral and Earth

-

-

-

... More
Incomer - 2 : DG

-

-

-

... More
1 Nos - 4000A, 4P, 65kA Drawout type, motor operated ACB with Microprocessor based releases (with Over current / Earth fault / Short circuit ) & Trip & close Coil with Under Voltage releases, high speed closing feature with earthing, door interlock, automatic safety shutters to shroud the bus bar side and FRP sheet barrier on the incoming & outgoing cable sides of the circuit breaker. (Electrical & mechanical Interlock)

-

-

-

... More
Metering for Each Incomer:

-

-

-

... More
1No - Load Manager with RS485 Interface with Maxmimum Demand Indication + controller

-

-

-

... More
1Sets - Dual Core Cast Resin CTs of ratio 4000/5A, Class 0.5 for metering and class 5P10 for Protection. The CT burden shall be 10VA.

-

-

-

... More
1No - Undervoltage relay with time delay & Earth fault Relay

-

-

-

... More
2 Sets - 63A 4P MCB

-

-

-

... More
1set - RYB LED type indication lamps for Phase

-

-

-

... More
1set - RGA LED type indication lamps for ON/OFF/Trip

-

-

-

... More
1Set - Control MCB with Neutral link

-

-

-

... More
Bus coupler:

-

-

-

... More
1No - 4000A, 4P, 65kA Drawout type, motor operated ACB with Microprocessor based releases (without Protection) high speed closing feature with earthing, door interlock, automatic safety shutters to shroud the bus bar side and FRP sheet barrier on the incoming & outgoing cable sides of the circuit breaker.

-

-

-

... More
Section - B

-

-

-

... More
Incomer - 1 : EB

-

-

-

... More
1 Nos - 4000A, 4P, 65kA Drawout type, motor operated ACB with Microprocessor based releases (with Over current / Earth fault / Short circuit ) & Trip & close Coil with Under Voltage releases, high speed closing feature with earthing, door interlock, automatic safety shutters to shroud the bus bar side and FRP sheet barrier on the incoming & outgoing cable sides of the circuit breaker. (Electrical & mechanical Interlock)

-

-

-

... More
Metering for Each Incomer:

-

-

-

... More
1No - Load Manager with RS485 Interface with Maxmimum Demand Indication + controller

-

-

-

... More
1Sets - Dual Core Cast Resin CTs of ratio 4000/5A, Class 0.5 for metering and class 5P10 for Protection. The CT burden shall be 10VA.

-

-

-

... More
1set - 4000/5A, Cl:0.5 for metering. The CT burden shall be 10VA.Resin cast CT's for APFCR. Except DG incomer

-

-

-

... More
1No - Undervoltage relay with time delay & Earth fault Relay

-

-

-

... More
2 Sets - 63A 4P MCB

-

-

-

... More
1set - RYB LED type indication lamps for Phase

-

-

-

... More
1set - RGA LED type indication lamps for ON/OFF/Trip

-

-

-

... More
1Set - Control MCB with Neutral link

-

-

-

... More
1set - class B(125KA) - 3 Numbers of lightning arrester for the connection between Phase and Neutral and one number of lightning arrester between Neutral and Earth

-

-

-

... More
Incomer - 2 : DG

-

-

-

... More
1 Nos - 4000A, 4P, 65kA Drawout type, motor operated ACB with Microprocessor based releases (with Over current / Earth fault / Short circuit ) & Trip & close Coil with Under Voltage releases, high speed closing feature with earthing, door interlock, automatic safety shutters to shroud the bus bar side and FRP sheet barrier on the incoming & outgoing cable sides of the circuit breaker. (Electrical & mechanical Interlock)

-

-

-

... More
Metering for Each Incomer:

-

-

-

... More
1No - Load Manager with RS485 Interface with Maxmimum Demand Indication + controller

-

-

-

... More
1Sets - Dual Core Cast Resin CTs of ratio 4000/5A, Class 0.5 for metering and class 5P10 for Protection. The CT burden shall be 10VA.

-

-

-

... More
1No - Undervoltage relay with time delay & Earth fault Relay

-

-

-

... More
2 Sets - 63A 4P MCB

-

-

-

... More
1set - RYB LED type indication lamps for Phase

-

-

-

... More
1set - RGA LED type indication lamps for ON/OFF/Trip

-

-

-

... More
1Set - Control MCB with Neutral link

-

-

-

... More
Electrical & Mechanical Interlock provided between incomers & Buscouplers with control wiring.

-

-

-

... More
Outgoings

-

-

-

... More
6 Nos - 2500A 50KA 4P Manual Drawout type, ACB with Microprocessor based releases high speed closing feature with earthing, door interlock, automatic safety shutters to shroud the bus bar side and FRP sheet barrier on the incoming & outgoing cable sides of the circuit breaker.

-

-

-

... More
6 Nos - 1600A 50KA 4P Manual Drawout type, ACB with Microprocessor based releases high speed closing feature with earthing, door interlock, automatic safety shutters to shroud the bus bar side and FRP sheet barrier on the incoming & outgoing cable sides of the circuit breaker.

-

-

-

... More
2 Nos - 1250A 50KA Manual Drawout type, ACB with Microprocessor based releases high speed closing feature with earthing, door interlock, automatic safety shutters to shroud the bus bar side and FRP sheet barrier on the incoming & outgoing cable sides of the circuit breaker.

-

-

-

... More
6 Nos - 630A 50KA 4P Microprocessor based MCCB with front drive kit & associated protections MCB's, R,Y,B Phase Indicating lamps and control circuit as required

-

-

-

... More
3 Nos - 400A 50KA 4P Microprocessor based MCCB with front drive kit & associated protections MCB's, R,Y,B Phase Indicating lamps and control circuit as required

-

-

-

... More
1 Nos - 315A 50KA 4P Microprocessor based MCCB with front drive kit & associated protections MCB's, R,Y,B Phase Indicating lamps and control circuit as required

-

-

-

... More
4 Nos - 250A 50KA 4P Microprocessor based MCCB with front drive kit & associated protections MCB's, R,Y,B Phase Indicating lamps and control circuit as required

-

-

-

... More
Doors: 2mm Body: 2mm Gland: 3mm covers and partitions:1.6mm

-

-

-

... More
1Sets - 2NO + 2NC potential free auxiliary contacts with shunt trip coil shall be provided

-

-

-

... More
Panel Size - LENGTH - 21Mtr X 1.5Mtr Deepth X 2.2Mtr Height

-

-

-

... More
Tinned Copper Busbar with heat shirnkable colour coded sleeve with SMC Bus bar supports Busbar Phase: 3R X 125 X 10mm Neutral : 3R X 125 X 10mm

-

-

-

... More
APFC Panel

2

-

-

... More
Design, Supply, Installation Testing & Commissioning of APFC Panel consist of Length - 4Mtr X 1Mtr Deepth X 2.1Mtr Height) suitable for 415Volts 3Phase 4wire system, fabricated from CRCA sheet steel (Doors:2mm Body:2mm Gland:3mm covers and partitions:1.6mm,) single fronted, free standing, front hinged, rear removable, extendable on both sides, dust & vermin proof, cubicle type, floor mounted, undrilled gland plates at top / bottom, complete with internal wiring, ferrules, name plates, painting etc., conforming to the technical specification for panels & comprising of the following. (Refer enclosed SLD) Tinned Copper Busbar with heat shirnkable colour coded sleeve with SMC Bus bar supports Tinned Copper Busbar with heat shirnkable colour coded sleeve with SMC Bus bar supports Busbar Phase: 2R X 125 X 10mm Neutral : 1R X 125 X 10mm Panel should be fully comply to IEC 61439 part 1 & 2 of type tested assembly (TTA) in addtion to the internal arc test and tempeture rise test at multiple point with necssary test certificate to be submit

-

-

-

... More
Incomer:

-

-

-

... More
1no -2500A, 50KA, TPN Manual Drawout type, ACB with Microprocessor based releases high speed closing feature with earthing, door interlock, automatic safety shutters to shroud the bus bar side and FRP sheet barrier on the incoming & outgoing cable sides of the circuit breaker.

-

-

-

... More
Bus bars:

-

-

-

... More
Tinned Copper Busbar with heat shirnkable colour coded sleeve with SMC Bus bar supports Busbar Phase: 2R X 125 X 10mm Neutral : 1R X 125 X 10mm

-

-

-

... More
Outgoings:

-

-

-

... More
All Capacitor Bank with Auto/Manual selector switch, Manual push button with on delay timers, ON/OFF Indication lamps and 7% Detuned Harmonic filter with discharge resistors arrangement to be provided.

-

-

-

... More
5 Sets - Each comprising 400A TP , 35KA MCCB with Capacitor duty contactor, manual over ride circuitary with push buttons & on delay timers in manual circuit, indication lamps for capacitor ON/OFF, three phase delta connected 2x50KVAR, 525Volt Epcos/Meher heavy duty capacitor, with harmonic reactor 7% detuned copper reactor shall be provided

-

-

-

... More
6 Sets - Each comprising 200A TP , 35KA MCCB with Capacitor duty contactor, manual over ride circuitary with push buttons & on delay timers in manual circuit, indication lamps for capacitor ON/OFF, three phase delta connected 2x25KVAR, 525Volt Epcos/Meher heavy duty capacitor, with harmonic reactor 7% detuned copper reactor shall be provided

-

-

-

... More
1 Sets - Each comprising 63A TP , 35KA MCCB with Capacitor duty contactor, manual over ride circuitary with push buttons & on delay timers in manual circuit, indication lamps for capacitor ON/OFF, three phase delta connected 1x25KVAR, 525Volt Epcos/Meher heavy duty capacitor, with harmonic reactor 7% detuned copper reactor shall be provided

-

-

-

... More
1 Sets - Each comprising 63A TP , 35KA MCCB with Capacitor duty contactor, manual over ride circuitary with push buttons & on delay timers in manual circuit, indication lamps for capacitor ON/OFF, three phase delta connected 1x15KVAR, 525Volt Epcos/Meher heavy duty capacitor, with harmonic reactor 7% detuned copper reactor shall be provided

-

-

-

... More
1 Sets - Each comprising 63A TP , 35KA MCCB with Capacitor duty contactor, manual over ride circuitary with push buttons & on delay timers in manual circuit, indication lamps for capacitor ON/OFF, three phase delta connected 1x10KVAR, 525Volt Epcos/Meher heavy duty capacitor, with harmonic reactor 7% detuned copper reactor shall be provided

-

-

-

... More
Doors: 2mm Body: 2mm Gland: 3mm covers and partitions:1.6mm

-

-

-

... More
Approximate Panel Size - LENGTH - 4Mtr X 1Mtr Deepth X 2.1Mtr Height

-

-

-

... More
Busduct Entry: at Top

-

-

-

... More
WATER COOLED CHILLER PANEL

1

-

-

... More
Design, Supply, Installation Testing & Commissioning of WATER COOLED CHILLER Panel (capacity of 375 TR 3 Nos (2W + 1S) consist of Length - 3.Mtr X 1Mtr Deepth X 2.1Mtr Height suitable for 415Volts 3Phase 4wire system, fabricated from CRCA sheet steel (Doors:2mm Body:2mm Gland:3mm covers and partitions:1.6mm,) single fronted, free standing, front hinged, rear removable, extendable on both sides, dust & vermin proof, cubicle type, floor mounted, undrilled gland plates at top / bottom, complete with internal wiring, ferrules, name plates, painting etc., conforming to the technical specification for panels & comprising of the following. (Refer enclosed SLD) Tinned Copper Busbar with heat shirnkable colour coded sleeve with SMC Bus bar supports Tinned Copper Busbar with heat shirnkable colour coded sleeve with SMC Bus bar supports Busbar Phase: 2R X 80 X 10mm Neutral : 1R X 80 X 10mm Panel should be fully comply to IEC 61439 part 1 & 2 of type tested assembly (TTA) in addtion to the internal arc test and tempeture rise test at multiple point with nesssry test certificate to be submit

-

-

-

... More
Incomer:

-

-

-

... More
1No - 1600A, 36KA,4P ATS associated protections MCB's, R,Y,B Phase Indicating lamps and control circuit as required

-

-

-

... More
1No - 1600A, 36KA,4P ACB Manual Drawout type, ACB with Microprocessor based releases high speed closing feature with earthing, door interlock, automatic safety shutters to shroud the bus bar side and FRP sheet barrier on the incoming & outgoing cable sides of the circuit breaker.

-

-

-

... More
Tinned Copper Busbar with heat shirnkable colour coded sleeve with SMC Bus bar supports Busbar Phase: 2R X 80 X 10mm Neutral : 1R X 80 X 10mm

-

-

-

... More
Common Metering :

-

-

-

... More
1Nos - 96sqmm Digital type . Energy meter RS 485 Port

-

-

-

... More
1set - Current Transformers (Cast resin type) 1600/5A, class 0.5, 10VA

-

-

-

... More
1set - RYB LED type indication lamps for Phase

-

-

-

... More
1set - RGA LED type indication lamps for ON/OFF/Trip

-

-

-

... More
1Set - Control MCB with Neutral link

-

-

-

... More
1Set - Class B+C SPD with control MCB

-

-

-

... More
Outgoings

-

-

-

... More
4 Nos - 630A 25KA 4P Microprocessor based MCCB with front drive kit & associated protections MCB's, R,Y,B Phase Indicating lamps and control circuit as required

-

-

-

... More
4 Nos -80A 25KA 4P MCCB with TM based O/C & S/C Release front drive kit & associated protections MCB's, R,Y,B Phase Indicating lamps and control circuit as required

-

-

-

... More
10 Nos -63A 25KA 4P MCCB with TM based O/C & S/C Release front drive kit & associated protections MCB's, R,Y,B Phase Indicating lamps and control circuit as required

-

-

-

... More
Approximate Panel Size - LENGTH - 3.Mtr X 1Mtr Deepth X 2.1Mtr Height

-

-

-

... More
Doors: 2mm Body: 2mm Gland: 3mm covers and partitions:1.6mm

-

-

-

... More
AIR COOLED CHILLAR PANEL - 1

1

-

-

... More
Design, Supply, Testing & Commissioning of AIR COOLED CHILLER Panel - 1 (capacity of 375 TR 2 Nos (2W) consist of Length - 3.Mtr X 1Mtr Deepth X 2.1Mtr Height suitable for 415Volts 3Phase 4wire system, fabricated from CRCA sheet steel (Doors:2mm Body:2mm Gland:3mm covers and partitions:1.6mm,) single fronted, free standing, front hinged, rear removable, extendable on both sides, dust & vermin proof, cubicle type, floor mounted, undrilled gland plates at top / bottom, complete with internal wiring, ferrules, name plates, painting etc., conforming to the technical specification for panels & comprising of the following. (Refer enclosed SLD) Tinned Copper Busbar with heat shirnkable colour coded sleeve with SMC Bus bar supports Tinned Copper Busbar with heat shirnkable colour coded sleeve with SMC Bus bar supports Busbar Phase: 2R X 125 X 10mm Neutral : 1R X 125 X 10mm Panel should be fully comply to IEC 61439 part 1 & 2 of type tested assembly (TTA) in addtion to the internal arc test and tempeture rise test at multiple point with necessary test certificate to be submit

-

-

-

... More
Incomer:

-

-

-

... More
1No - 2500A, 36KA,4P ATS associated protections MCB's, R,Y,B Phase Indicating lamps and control circuit as required

-

-

-

... More
1No - 2500A, 36KA,4P Manual Drawout type, ACB with Microprocessor based releases high speed closing feature with earthing, door interlock, automatic safety shutters to shroud the bus bar side and FRP sheet barrier on the incoming & outgoing cable sides of the circuit breaker.

-

-

-

... More
Tinned Copper Busbar with heat shirnkable colour coded sleeve with SMC Bus bar supports Busbar Phase: 2R X 125 X 10mm Neutral : 1R X 125 X 10mm

-

-

-

... More
Common Metering :

-

-

-

... More
1Nos - 96sqmm Digital type . Energy meter RS 485 Port

-

-

-

... More
1set - Current Transformers (Cast resin type) 2500/5A, class 0.5, 10VA

-

-

-

... More
1set - RYB LED type indication lamps for Phase

-

-

-

... More
1set - RGA LED type indication lamps for ON/OFF/Trip

-

-

-

... More
1Set - Control MCB with Neutral link

-

-

-

... More
1Set - Class B+C SPD with control MCB

-

-

-

... More
Outgoings

-

-

-

... More
3 Nos - 1000A 25KA 4P Manual Drawout type, ACB with Microprocessor based releases high speed closing feature with earthing, door interlock, automatic safety shutters to shroud the bus bar side and FRP sheet barrier on the incoming & outgoing cable sides of the circuit breaker.

-

-

-

... More
6 Nos - 63A 25KA 4P MCCB with TM based O/C & S/C Release front drive kit & associated protections MCB's, R,Y,B Phase Indicating lamps and control circuit as required

-

-

-

... More
Approximate Panel Size - LENGTH - 2.5Mtr X 1Mtr Deepth X 2.1Mtr Height

-

-

-

... More
Doors: 2mm Body: 2mm Gland: 3mm covers and partitions:1.6mm

-

-

-

... More
AIR COOLED CHILLAR PANEL - 2

1

-

-

... More
Design, Supply, Testing & Commissioning of AIR COOLED CHILLER Panel - 2 (capacity of 150 TR 2 Nos (1W+1S) consist of Length - 2.5Mtr X 1Mtr Deepth X 2.1Mtr Height suitable for 415Volts 3Phase 4wire system, fabricated from CRCA sheet steel (Doors:2mm Body:2mm Gland:3mm covers and partitions:1.6mm,) single fronted, free standing, front hinged, rear removable, extendable on both sides, dust & vermin proof, cubicle type, floor mounted, undrilled gland plates at top / bottom, complete with internal wiring, ferrules, name plates, painting etc., conforming to the technical specification for panels & comprising of the following. (Refer enclosed SLD) Tinned Copper Busbar with heat shirnkable colour coded sleeve with SMC Bus bar supports Tinned Copper Busbar with heat shirnkable colour coded sleeve with SMC Bus bar supports Busbar Phase: 1R X 50 X 10mm Neutral : 1R X 50 X 6mm Panel should be fully comply to IEC 61439 part 1 & 2 of type tested assembly (TTA) in addtion to the internal arc test and tempeture rise test at multiple point with necessary test certificate to be submit

-

-

-

... More
Incomer:

-

-

-

... More
1No - 630A, 36KA,4P ATS associated protections MCB's, R,Y,B Phase Indicating lamps and control circuit as required

-

-

-

... More
1No - 630A, 36KA, 4P Microprocessor based MCCB with front drive kit & associated protections MCB's, R,Y,B Phase Indicating lamps and control circuit as required

-

-

-

... More
Tinned Copper Busbar with heat shirnkable colour coded sleeve with SMC Bus bar supports Busbar Phase: 1R X 50 X 10mm Neutral : 1R X 50 X 6mm

-

-

-

... More
Common Metering :

-

-

-

... More
1Nos - 96sqmm Digital type . Energy meter RS 485 Port

-

-

-

... More
1set - Current Transformers (Cast resin type) 630/5A, class 0.5, 10VA

-

-

-

... More
1set - RYB LED type indication lamps for Phase

-

-

-

... More
1set - RGA LED type indication lamps for ON/OFF/Trip

-

-

-

... More
1Set - Control MCB with Neutral link

-

-

-

... More
1Set - Class B+C SPD with control MCB

-

-

-

... More
Outgoings

-

-

-

... More
3 Nos - 400A 4P MCCB wth TM based O/C & S/C Release (25kA) front drive kit with MFM with RS 485 (C.T.400/1A, CLASS 1.0 10VA) & associated protections MCB's, R,Y,B Phase Indicating lamps and control circuit as required

-

-

-

... More
6 Nos - 40A 4P MCCB wth TM based O/C & S/C Release (25kA) front drive kit with MFM with RS 485 & associated protections MCB's, R,Y,B Phase Indicating lamps and control circuit as required

-

-

-

... More
Approximate Panel Size - LENGTH - 2.5Mtr X 1Mtr Deepth X 2.1Mtr Height

-

-

-

... More
Doors: 2mm Body: 2mm Gland: 3mm covers and partitions:1.6mm

-

-

-

... More
LIFT PANEL - 1 & 2

2

-

-

... More
Design, Supply, Testing & Commissioning of LIFT PANEL - 1 & 2 consist of Length - 1.8Mtr X .45Mtr Deepth X 2.1Mtr Height suitable for 415Volts 3Phase 4wire system, fabricated from CRCA sheet steel (Doors:2mm Body:2mm Gland:3mm covers and partitions:1.6mm,) single fronted, free standing, front hinged, rear removable, extendable on both sides, dust & vermin proof, cubicle type, floor mounted, undrilled gland plates at top / bottom, complete with internal wiring, ferrules, name plates, painting etc., conforming to the technical specification for panels & comprising of the following. (Refer enclosed SLD) Tinned Copper Busbar with heat shirnkable colour coded sleeve with SMC Bus bar supports Tinned Copper Busbar with heat shirnkable colour coded sleeve with SMC Bus bar supports Busbar Phase: 1R X 25 X 10mm Neutral : 1R X 25 X 6mm Panel should be fully comply to IEC 61439 part 1 & 2 of type tested assembly (TTA) in addtion to the internal arc test and tempeture rise test at multiple point with nesssry test certificate to be submit

-

-

-

... More
Incomer:

-

-

-

... More
1No - 250A, 36KA,4P ATS associated protections MCB's, R,Y,B Phase Indicating lamps and control circuit as required

-

-

-

... More
1No - 250A, 36KA, 4P Microprocessor based MCCB with front drive kit & associated protections MCB's, R,Y,B Phase Indicating lamps and control circuit as required

-

-

-

... More
Tinned Copper Busbar with heat shirnkable colour coded sleeve with SMC Bus bar supports Busbar Phase: 1R X 25 X 10mm Neutral : 1R X 25 X 6mm

-

-

-

... More
Common Metering :

-

-

-

... More
1Nos - 96sqmm Digital type . Energy meter RS 485 Port

-

-

-

... More
1set - Current Transformers (Cast resin type) 250/5A, class 0.5, 10VA

-

-

-

... More
1set - RYB LED type indication lamps for Phase

-

-

-

... More
1set - RGA LED type indication lamps for ON/OFF/Trip

-

-

-

... More
1Set - Control MCB with Neutral link

-

-

-

... More
1Set - Class B+C SPD with control MCB

-

-

-

... More
Outgoings

-

-

-

... More
9 Nos - 63A 4P MCCB wth TM based O/C & S/C Release (25kA) front drive kit with MFM with RS 485 (C.T.63/1A, CLASS 1.0 10VA) & associated protections MCB's, R,Y,B Phase Indicating lamps and control circuit as required.

-

-

-

... More
Approximate Panel Size - LENGTH - 1.8Mtr X .45Mtr Deepth X 2.1Mtr Height

-

-

-

... More
Doors: 2mm Body: 2mm Gland: 3mm covers and partitions:1.6mm

-

-

-

... More
KITCHEN PANEL

1

-

-

... More
Design, Supply, Testing & Commissioning of KITCHEN PANEL consist of Length - 1.8Mtr X .45Mtr Deepth X 2.1Mtr Height suitable for 415Volts 3Phase 4wire system, fabricated from CRCA sheet steel (Doors:2mm Body:2mm Gland:3mm covers and partitions:1.6mm,) single fronted, free standing, front hinged, rear removable, extendable on both sides, dust & vermin proof, cubicle type, floor mounted, undrilled gland plates at top / bottom, complete with internal wiring, ferrules, name plates, painting etc., conforming to the technical specification for panels & comprising of the following. (Refer enclosed SLD) Tinned Copper Busbar with heat shirnkable colour coded sleeve with SMC Bus bar supports Tinned Copper Busbar with heat shirnkable colour coded sleeve with SMC Bus bar supports Busbar Phase: 1R X 50 X 10mm Neutral : 1R X 50 X 6mm Panel should be fully comply to IEC 61439 part 1 & 2 of type tested assembly (TTA) in addtion to the internal arc test and tempeture rise test at multiple point with nesssry test certificate to be submit

-

-

-

... More
Incomer:

-

-

-

... More
1No - 630A, 36KA, 4P Microprocessor based MCCB with front drive kit & associated protections MCB's, R,Y,B Phase Indicating lamps and control circuit as required

-

-

-

... More
Tinned Copper Busbar with heat shirnkable colour coded sleeve with SMC Bus bar supports Busbar Phase: 1R X 50 X 10mm Neutral : 1R X 50 X 6mm

-

-

-

... More
Common Metering :

-

-

-

... More
1Nos - 96 sqmm Digital type . Energy meter RS 485 Port

-

-

-

... More
1set - Current Transformers (Cast resin type) 630/5A, class 0.5, 10VA

-

-

-

... More
1set - RYB LED type indication lamps for Phase

-

-

-

... More
1set - RGA LED type indication lamps for ON/OFF/Trip

-

-

-

... More
1Set - Control MCB with Neutral link

-

-

-

... More
1Set - Class B+C SPD with control MCB

-

-

-

... More
Outgoings

-

-

-

... More
9 Nos - 63A 4P MCCB wth TM based O/C & S/C Release (25kA) front drive kit with MFM with RS 485 (C.T.63/1A, CLASS 1.0 10VA) & associated protections MCB's, R,Y,B Phase Indicating lamps and control circuit as required

-

-

-

... More
Doors: 2mm Body: 2mm Gland: 3mm covers and partitions:1.6mm

-

-

-

... More
Note: Refer Tech Specification & SLD for outgoing feeder arrangements

-

-

-

... More
UTILITY PANEL

1

-

-

... More
Design, Supply, Testing & Commissioning of UTILITY PANEL consist of Length - 1.8Mtr X .45Mtr Deepth X 2.1Mtr Height Height suitable for 415Volts 3Phase 4wire system, fabricated from CRCA sheet steel (Doors:2mm Body:2mm Gland:3mm covers and partitions:1.6mm,) single fronted, free standing, front hinged, rear removable, extendable on both sides, dust & vermin proof, cubicle type, floor mounted, undrilled gland plates at top / bottom, complete with internal wiring, ferrules, name plates, painting etc., conforming to the technical specification for panels & comprising of the following. (Refer enclosed SLD) Tinned Copper Busbar with heat shirnkable colour coded sleeve with SMC Bus bar supports Tinned Copper Busbar with heat shirnkable colour coded sleeve with SMC Bus bar supports Busbar Phase: 1R X 32 X 12mm Neutral : 1R X 32 X 6mm Panel should be fully comply to IEC 61439 part 1 & 2 of type tested assembly (TTA) in addtion to the internal arc test and tempeture rise test at multiple point with nesssry test certificate to be submit

-

-

-

... More
Incomer:

-

-

-

... More
1No - 400A, 36KA, 4P Microprocessor based MCCB with front drive kit & associated protections MCB's, R,Y,B Phase Indicating lamps and control circuit as required

-

-

-

... More
Tinned Copper Busbar with heat shirnkable colour coded sleeve with SMC Bus bar supports Busbar Phase: 1R X 32 X 12mm Neutral : 1R X 32 X 6mm

-

-

-

... More
Common Metering :

-

-

-

... More
1Nos - 96sqmm Digital type . Energy meter RS 485 Port

-

-

-

... More
1set - Current Transformers (Cast resin type) 400/5A, class 0.5, 10VA

-

-

-

... More
1set - RYB LED type indication lamps for Phase

-

-

-

... More
1set - RGA LED type indication lamps for ON/OFF/Trip

-

-

-

... More
1Set - Control MCB with Neutral link

-

-

-

... More
1Set - Class B+C SPD with control MCB

-

-

-

... More
Outgoings

-

-

-

... More
3 Nos - 250A 4P MCCB wth TM based O/C & S/C Release (25kA) front drive kit with MFM with RS 485 (C.T.250/1A, CLASS 1.0 10VA) & associated protections MCB's, R,Y,B Phase Indicating lamps, auto/manual selector and control circuit as required

-

-

-

... More
5 Nos - 125A 25KA 4P MCCB wth front drive kit & associated protections MCB's, R,Y,B Phase Indicating lamps, auto/manual selector and control circuit as required

-

-

-

... More
1 Nos - 63A 4P MCCB wth TM based O/C & S/C Release (25kA) front drive kit with MFM with RS 485 (C.T.63/1A, CLASS 1.0 10VA) & associated protections MCB's, R,Y,B Phase Indicating lamps, auto/manual selector and control circuit as required

-

-

-

... More
Doors: 2mm Body: 2mm Gland: 3mm covers and partitions:1.6mm

-

-

-

... More
Approximate Panel Size - LENGTH - 1.8Mtr X .45Mtr Deepth X 2.1Mtr Height

-

-

-

... More
Note: Refer Tech Specification & SLD for outgoing feeder arrangements

-

-

-

... More
COMMON PANEL - 1 & 2

2

-

-

... More
Design, Supply, Testing & Commissioning of COMMON PANEL - 1 & 2 consist of Length - 1.8Mtr X 0.45Mtr Deepth X 2.1Mtr Height Height suitable for 415Volts 3Phase 4wire system, fabricated from CRCA sheet steel (Doors:2mm Body:2mm Gland:3mm covers and partitions:1.6mm,) single fronted, free standing, front hinged, rear removable, extendable on both sides, dust & vermin proof, cubicle type, floor mounted, undrilled gland plates at top / bottom, complete with internal wiring, ferrules, name plates, painting etc., conforming to the technical specification for panels & comprising of the following. (Refer enclosed SLD) Tinned Copper Busbar with heat shirnkable colour coded sleeve with SMC Bus bar supports Tinned Copper Busbar with heat shirnkable colour coded sleeve with SMC Bus bar supports Busbar Phase: 1R X 25 X 6mm Neutral : 1R X 25 X 3mm Panel should be fully comply to IEC 61439 part 1 & 2 of type tested assembly (TTA) in addtion to the internal arc test and tempeture rise test at multiple point with nesssry test certificate to be submit

-

-

-

... More
Incomer:

-

-

-

... More
1No - 160A, 36KA,4P ATS associated protections MCB's, R,Y,B Phase Indicating lamps and control circuit as required

-

-

-

... More
1No - 160A, 36KA, 4P MCCB with TM based O/C & S/C Release (25kA) front drive kit & associated protections MCB's, R,Y,B Phase Indicating lamps, auto/manual selector and control circuit as required

-

-

-

... More
Tinned Copper Busbar with heat shirnkable colour coded sleeve with SMC Bus bar supports Busbar Phase: 1R X 25 X 6mm Neutral : 1R X 25 X 3mm

-

-

-

... More
Common Metering :

-

-

-

... More
1Nos - 96sqmm Digital type . Energy meter RS 485 Port

-

-

-

... More
1set - Current Transformers (Cast resin type) 160/5A, class 0.5, 10VA

-

-

-

... More
1set - RYB LED type indication lamps for Phase

-

-

-

... More
1set - RGA LED type indication lamps for ON/OFF/Trip

-

-

-

... More
1Set - Control MCB with Neutral link

-

-

-

... More
1Set - Class B+C SPD with control MCB

-

-

-

... More
Outgoings

-

-

-

... More
12 Nos - 63A 4P MCCB wth TM based O/C & S/C Release (25kA) front drive kit with MFM with RS 485 (C.T.63/1A, CLASS 1.0 10VA) associated protections MCB's, R,Y,B Phase Indicating lamps, auto/manual selector and control circuit as required

-

-

-

... More
Approximate Panel Size - LENGTH - 2.4Mtr X .45Mtr Deepth X 2.1Mtr Height

-

-

-

... More
Doors: 2mm Body: 2mm Gland: 3mm covers and partitions:1.6mm

-

-

-

... More
Note: Refer Tech Specification & SLD for outgoing feeder arrangements

-

-

-

... More
COMMON PANEL - 3 & 4

2

-

-

... More
Design, Supply, Testing & Commissioning of COMMON PANEL - 3 & 4 consist of Length - 2.4Mtr X .45Mtr Deepth X 2.1Mtr Height suitable for 415Volts 3Phase 4wire system, fabricated from CRCA sheet steel (Doors:2mm Body:2mm Gland:3mm covers and partitions:1.6mm,) single fronted, free standing, front hinged, rear removable, extendable on both sides, dust & vermin proof, cubicle type, floor mounted, undrilled gland plates at top / bottom, complete with internal wiring, ferrules, name plates, painting etc., conforming to the technical specification for panels & comprising of the following. (Refer enclosed SLD) Tinned Copper Busbar with heat shirnkable colour coded sleeve with SMC Bus bar supports Tinned Copper Busbar with heat shirnkable colour coded sleeve with SMC Bus bar supports Busbar Phase: 1R X 25 X 6mm Neutral : 1R X 25 X 3mm Panel should be fully comply to IEC 61439 part 1 & 2 of type tested assembly (TTA) in addtion to the internal arc test and tempeture rise test at multiple point with nesssry test certificate to be submit

-

-

-

... More
Incomer:

-

-

-

... More
1No - 160A, 36KA,4P ATS associated protections MCB's, R,Y,B Phase Indicating lamps and control circuit as required

-

-

-

... More
1No - 160A, 36KA, 4P MCCB with TM based O/C & S/C Release (25kA) front drive kit & associated protections MCB's, R,Y,B Phase Indicating lamps, auto/manual selector and control circuit as required

-

-

-

... More
Tinned Copper Busbar with heat shirnkable colour coded sleeve with SMC Bus bar supports Busbar Phase: 1R X 25 X 6mm Neutral : 1R X 25 X 3mm

-

-

-

... More
Common Metering :

-

-

-

... More
1Nos - 96sqmm Digital type . Energy meter RS 485 Port

-

-

-

... More
1set - Current Transformers (Cast resin type) 160/5A, class 0.5, 10VA

-

-

-

... More
1set - RYB LED type indication lamps for Phase

-

-

-

... More
1set - RGA LED type indication lamps for ON/OFF/Trip

-

-

-

... More
1Set - Control MCB with Neutral link

-

-

-

... More
1Set - Class B+C SPD with control MCB

-

-

-

... More
Outgoings

-

-

-

... More
13 Nos - 63A 4P MCCB wth TM based O/C & S/C Release (25kA) front drive kit with MFM with RS 485 (C.T.63/1A, CLASS 1.0 10VA) & associated protections MCB's, R,Y,B Phase Indicating lamps, auto/manual selector and control circuit as required

-

-

-

... More
Approximate Panel Size - LENGTH - 2.4Mtr X .45Mtr Deepth X 2.1Mtr Height

-

-

-

... More
Doors: 2mm Body: 2mm Gland: 3mm covers and partitions:1.6mm

-

-

-

... More
Note: Refer Tech Specification & SLD for outgoing feeder arrangements

-

-

-

... More
COMMON PANEL - 5 & 6

2

-

-

... More
Design, Supply, Testing & Commissioning of COMMON PANEL - 5 & 6 consist of Length - 2.4Mtr X .45Mtr Deepth X 2.1Mtr Height suitable for 415Volts 3Phase 4wire system, fabricated from CRCA sheet steel (Doors:2mm Body:2mm Gland:3mm covers and partitions:1.6mm,) single fronted, free standing, front hinged, rear removable, extendable on both sides, dust & vermin proof, cubicle type, floor mounted, undrilled gland plates at top / bottom, complete with internal wiring, ferrules, name plates, painting etc., conforming to the technical specification for panels & comprising of the following. (Refer enclosed SLD) Tinned Copper Busbar with heat shirnkable colour coded sleeve with SMC Bus bar supports Tinned Copper Busbar with heat shirnkable colour coded sleeve with SMC Bus bar supports Busbar Phase: 1R X 25 X 6mm Neutral : 1R X 25 X 3mm Panel should be fully comply to IEC 61439 part 1 & 2 of type tested assembly (TTA) in addtion to the internal arc test and tempeture rise test at multiple point with nesssry test certificate to be submit

-

-

-

... More
Incomer:

-

-

-

... More
1No - 160A, 36KA,4P ATS associated protections MCB's, R,Y,B Phase Indicating lamps and control circuit as required

-

-

-

... More
1No - 160A, 36KA, 4P MCCB with TM based O/C & S/C Release (25kA) front drive kit & associated protections MCB's, R,Y,B Phase Indicating lamps, auto/manual selector and control circuit as required

-

-

-

... More
Tinned Copper Busbar with heat shirnkable colour coded sleeve with SMC Bus bar supports Busbar Phase: 1R X 25 X 6mm Neutral : 1R X 25 X 3mm

-

-

-

... More
Common Metering :

-

-

-

... More
1Nos - 96sqmm Digital type . Energy meter RS 485 Port

-

-

-

... More
1set - Current Transformers (Cast resin type) 160/5A, class 0.5, 10VA

-

-

-

... More
1set - RYB LED type indication lamps for Phase

-

-

-

... More
1set - RGA LED type indication lamps for ON/OFF/Trip

-

-

-

... More
1Set - Control MCB with Neutral link

-

-

-

... More
1Set - Class B+C SPD with control MCB

-

-

-

... More
Outgoings

-

-

-

... More
12 Nos - 63A 4P MCCB wth TM based O/C & S/C Release (25kA) front drive kit with MFM with RS 485 (C.T.63/1A, CLASS 1.0 10VA) & associated protections MCB's, R,Y,B Phase Indicating lamps, auto/manual selector and control circuit as required

-

-

-

... More
Approximate Panel Size - LENGTH - 2.4Mtr X .45Mtr Deepth X 2.1Mtr Height

-

-

-

... More
Note: Refer Tech Specification & SLD for outgoing feeder arrangements

-

-

-

... More
COMMON PANEL - 7 & 8

2

-

-

... More
Design, Supply, Testing & Commissioning of COMMON PANEL - 7 & 8 consist of Length - 2.4Mtr X .45Mtr Deepth X 2.1Mtr Height suitable for 415Volts 3Phase 4wire system, fabricated from CRCA sheet steel (Doors:2mm Body:2mm Gland:3mm covers and partitions:1.6mm,) single fronted, free standing, front hinged, rear removable, extendable on both sides, dust & vermin proof, cubicle type, floor mounted, undrilled gland plates at top / bottom, complete with internal wiring, ferrules, name plates, painting etc., conforming to the technical specification for panels & comprising of the following. (Refer enclosed SLD) Tinned Copper Busbar with heat shirnkable colour coded sleeve with SMC Bus bar supports Tinned Copper Busbar with heat shirnkable colour coded sleeve with SMC Bus bar supports Busbar Phase: 1R X 25 X 6mm Neutral : 1R X 25 X 3mm Panel should be fully comply to IEC 61439 part 1 & 2 of type tested assembly (TTA) in addtion to the internal arc test and tempeture rise test at multiple point with nesssry test certificate to be submit

-

-

-

... More
Incomer:

-

-

-

... More
1No - 160A, 36KA,4P ATS associated protections MCB's, R,Y,B Phase Indicating lamps and control circuit as required

-

-

-

... More
1No - 160A, 36KA, 4P MCCB with TM based O/C & S/C Release (25kA) front drive kit & associated protections MCB's, R,Y,B Phase Indicating lamps, auto/manual selector and control circuit as required

-

-

-

... More
Tinned Copper Busbar with heat shirnkable colour coded sleeve with SMC Bus bar supports Busbar Phase: 1R X 25 X 6mm Neutral : 1R X 25 X 3mm

-

-

-

... More
Common Metering :

-

-

-

... More
1Nos - 96sqmm Digital type . Energy meter RS 485 Port

-

-

-

... More
1set - Current Transformers (Cast resin type) 160/5A, class 0.5, 10VA

-

-

-

... More
1set - RYB LED type indication lamps for Phase

-

-

-

... More
1set - RGA LED type indication lamps for ON/OFF/Trip

-

-

-

... More
1Set - Control MCB with Neutral link

-

-

-

... More
1Set - Class B+C SPD with control MCB

-

-

-

... More
Outgoings

-

-

-

... More
13 Nos - 63A 4P MCCB wth TM based O/C & S/C Release (25kA) front drive kit with MFM with RS 485 (C.T.63/1A, CLASS 1.0 10VA)& associated protections MCB's, R,Y,B Phase Indicating lamps, auto/manual selector and control circuit as required.

-

-

-

... More
Doors: 2mm Body: 2mm Gland: 3mm covers and partitions:1.6mm

-

-

-

... More
Approximate Panel Size - LENGTH - 2.4Mtr X .45Mtr Deepth X 2.1Mtr Height

-

-

-

... More
Note: Refer Tech Specification & SLD for outgoing feeder arrangements

-

-

-

... More
COMMON PANEL - 9 & 10

2

-

-

... More
Design, Supply, Testing & Commissioning of COMMON PANEL - 9 & 10 consist of Length - 2.4Mtr X .45Mtr Deepth X 2.1Mtr Height suitable for 415Volts 3Phase 4wire system, fabricated from CRCA sheet steel (Doors:2mm Body:2mm Gland:3mm covers and partitions:1.6mm,) single fronted, free standing, front hinged, rear removable, extendable on both sides, dust & vermin proof, cubicle type, floor mounted, undrilled gland plates at top / bottom, complete with internal wiring, ferrules, name plates, painting etc., conforming to the technical specification for panels & comprising of the following. (Refer enclosed SLD) Tinned Copper Busbar with heat shirnkable colour coded sleeve with SMC Bus bar supports Tinned Copper Busbar with heat shirnkable colour coded sleeve with SMC Bus bar supports Busbar Phase: 1R X 25 X 6mm Neutral : 1R X 25 X 3mm Panel should be fully comply to IEC 61439 part 1 & 2 of type tested assembly (TTA) in addtion to the internal arc test and tempeture rise test at multiple point with nesssry test certificate to be submit

-

-

-

... More
Incomer:

-

-

-

... More
1No - 160A, 36KA,4P ATS associated protections MCB's, R,Y,B Phase Indicating lamps and control circuit as required

-

-

-

... More
1No - 160A, 36KA, 4P MCCB with TM based O/C & S/C Release (25kA) front drive kit & associated protections MCB's, R,Y,B Phase Indicating lamps, auto/manual selector and control circuit as required

-

-

-

... More
Tinned Copper Busbar with heat shirnkable colour coded sleeve with SMC Bus bar supports Busbar Phase: 1R X 25 X 6mm Neutral : 1R X 25 X 3mm

-

-

-

... More
Common Metering :

-

-

-

... More
1Nos - 96sqmm Digital type . Energy meter RS 485 Port

-

-

-

... More
1set - Current Transformers (Cast resin type) 160/5A, class 0.5, 10VA

-

-

-

... More
1set - RYB LED type indication lamps for Phase

-

-

-

... More
1set - RGA LED type indication lamps for ON/OFF/Trip

-

-

-

... More
1Set - Control MCB with Neutral link

-

-

-

... More
1Set - Class B+C SPD with control MCB

-

-

-

... More
Outgoings

-

-

-

... More
13 Nos - 63A 4P MCCB wth TM based O/C & S/C Release (25kA) front drive kit with MFM with RS 485 (C.T.63/1A, CLASS 1.0 10VA)& associated protections MCB's, R,Y,B Phase Indicating lamps, auto/manual selector and control circuit as required.

-

-

-

... More
Doors: 2mm Body: 2mm Gland: 3mm covers and partitions:1.6mm

-

-

-

... More
Approximate Panel Size - LENGTH - 2.4Mtr X .45Mtr Deepth X 2.1Mtr Height

-

-

-

... More
Note: Refer Tech Specification & SLD for outgoing feeder arrangements

-

-

-

... More
COMMON PANEL - 11, 12, 13 & 14

4

-

-

... More
Design, Supply, Testing & Commissioning of COMMON PANEL - 11 to 14 consist of Length - 2.4Mtr X .45Mtr Deepth X 2.1Mtr Height suitable for 415Volts 3Phase 4wire system, fabricated from CRCA sheet steel (Doors:2mm Body:2mm Gland:3mm covers and partitions:1.6mm,) single fronted, free standing, front hinged, rear removable, extendable on both sides, dust & vermin proof, cubicle type, floor mounted, undrilled gland plates at top / bottom, complete with internal wiring, ferrules, name plates, painting etc., conforming to the technical specification for panels & comprising of the following. (Refer enclosed SLD) Tinned Copper Busbar with heat shirnkable colour coded sleeve with SMC Bus bar supports Tinned Copper Busbar with heat shirnkable colour coded sleeve with SMC Bus bar supports Busbar Phase: 1R X 25 X 6mm Neutral : 1R X 25 X 3mm Panel should be fully comply to IEC 61439 part 1 & 2 of type tested assembly (TTA) in addtion to the internal arc test and tempeture rise test at multiple point with nesssry test certificate to be submit

-

-

-

... More
Incomer:

-

-

-

... More
1No - 160A, 36KA,4P ATS associated protections MCB's, R,Y,B Phase Indicating lamps and control circuit as required

-

-

-

... More
1No - 160A, 36KA, 4P MCCB with TM based O/C & S/C Release (25kA) front drive kit & associated protections MCB's, R,Y,B Phase Indicating lamps, auto/manual selector and control circuit as required

-

-

-

... More
Tinned Copper Busbar with heat shirnkable colour coded sleeve with SMC Bus bar supports Busbar Phase: 1R X 25 X 6mm Neutral : 1R X 25 X 3mm

-

-

-

... More
Common Metering :

-

-

-

... More
1Nos - 96sqmm Digital type . Energy meter RS 485 Port

-

-

-

... More
1set - Current Transformers (Cast resin type) 160/5A, class 0.5, 10VA

-

-

-

... More
1set - RYB LED type indication lamps for Phase

-

-

-

... More
1set - RGA LED type indication lamps for ON/OFF/Trip

-

-

-

... More
1Set - Control MCB with Neutral link

-

-

-

... More
1Set - Class B+C SPD with control MCB

-

-

-

... More
Outgoings

-

-

-

... More
13 Nos - 63A 4P MCCB wth TM based O/C & S/C Release (25kA) front drive kit with MFM with RS 485 (C.T.63/1A, CLASS 1.0 10VA)& associated protections MCB's, R,Y,B Phase Indicating lamps, auto/manual selector and control circuit as required.

-

-

-

... More
Doors: 2mm Body: 2mm Gland: 3mm covers and partitions:1.6mm

-

-

-

... More
Approximate Panel Size - LENGTH - 2.4Mtr X .45Mtr Deepth X 2.1Mtr Height

-

-

-

... More
Note: Refer Tech Specification & SLD for outgoing feeder arrangements

-

-

-

... More
OFFICE PANEL - 1 & 2

2

-

-

... More
Design, Supply, Testing & Commissioning of OFFICE PANEL - 1 & 2 consist of Length - 1.8Mtr X .45Mtr Deepth X 2.1Mtr Height suitable for 415Volts 3Phase 4wire system, fabricated from CRCA sheet steel (Doors:2mm Body:2mm Gland:3mm covers and partitions:1.6mm,) single fronted, free standing, front hinged, rear removable, extendable on both sides, dust & vermin proof, cubicle type, floor mounted, undrilled gland plates at top / bottom, complete with internal wiring, ferrules, name plates, painting etc., conforming to the technical specification for panels & comprising of the following. (Refer enclosed SLD) Tinned Copper Busbar with heat shirnkable colour coded sleeve with SMC Bus bar supports Tinned Copper Busbar with heat shirnkable colour coded sleeve with SMC Bus bar supports Busbar Phase: 1R X 25 X 10mm Neutral : 1R X 25 X 6mm Panel should be fully comply to IEC 61439 part 1 & 2 of type tested assembly (TTA) in addtion to the internal arc test and tempeture rise test at multiple point with nesssry test certificate to be submit

-

-

-

... More
Incomer:

-

-

-

... More
1No - 250A, 36KA,4P MTS associated protections MCB's, R,Y,B Phase Indicating lamps and control circuit as required

-

-

-

... More
1No - 250A, 36KA, 4P MCCB with TM based O/C & S/C Release (25kA) front drive kit & associated protections MCB's, R,Y,B Phase Indicating lamps, auto/manual selector and control circuit as required

-

-

-

... More
Tinned Copper Busbar with heat shirnkable colour coded sleeve with SMC Bus bar supports Busbar Phase: 1R X 25 X 10mm Neutral : 1R X 25 X 6mm

-

-

-

... More
Common Metering :

-

-

-

... More
1Nos - 96sqmm Digital type . Energy meter RS 485 Port

-

-

-

... More
1set - Current Transformers (Cast resin type) 250/5A, class 0.5, 10VA

-

-

-

... More
1set - RYB LED type indication lamps for Phase

-

-

-

... More
1set - RGA LED type indication lamps for ON/OFF/Trip

-

-

-

... More
1Set - Control MCB with Neutral link

-

-

-

... More
1Set - Class B+C SPD with control MCB

-

-

-

... More
Outgoings

-

-

-

... More
7 Nos - 125A 4P MCCB wth TM based O/C & S/C Release (25kA) front drive kit with MFM with RS 485 (C.T.125/1A, CLASS 1.0 10VA) & associated protections MCB's, R,Y,B Phase Indicating lamps, auto/manual selector and control circuit as required

-

-

-

... More
Doors: 2mm Body: 2mm Gland: 3mm covers and partitions:1.6mm

-

-

-

... More
Approximate Panel Size - LENGTH - 1.8Mtr X .45Mtr Deepth X 2.1Mtr Height

-

-

-

... More
Note: Refer Tech Specification & SLD for outgoing feeder arrangements

-

-

-

... More
OFFICE PANEL - 3 & 4

2

-

-

... More
Design, Supply, Testing & Commissioning of OFFICE PANEL - 3 & 4 consist of Length - 1.8Mtr X .45Mtr Deepth X 2.1Mtr Height suitable for 415Volts 3Phase 4wire system, fabricated from CRCA sheet steel (Doors:2mm Body:2mm Gland:3mm covers and partitions:1.6mm,) single fronted, free standing, front hinged, rear removable, extendable on both sides, dust & vermin proof, cubicle type, floor mounted, undrilled gland plates at top / bottom, complete with internal wiring, ferrules, name plates, painting etc., conforming to the technical specification for panels & comprising of the following. (Refer enclosed SLD) Tinned Copper Busbar with heat shirnkable colour coded sleeve with SMC Bus bar supports Tinned Copper Busbar with heat shirnkable colour coded sleeve with SMC Bus bar supports Busbar Phase: 1R X 25 X 10mm Neutral : 1R X 25 X 6mm Panel should be fully comply to IEC 61439 part 1 & 2 of type tested assembly (TTA) in addtion to the internal arc test and tempeture rise test at multiple point with nesssry test certificate to be submit

-

-

-

... More
Incomer:

-

-

-

... More
1No - 250A, 36KA,4P MTS associated protections MCB's, R,Y,B Phase Indicating lamps and control circuit as required

-

-

-

... More
1No - 250A, 36KA, 4P MCCB with TM based O/C & S/C Release (25kA) front drive kit & associated protections MCB's, R,Y,B Phase Indicating lamps, auto/manual selector and control circuit as required

-

-

-

... More
Tinned Copper Busbar with heat shirnkable colour coded sleeve with SMC Bus bar supports Busbar Phase: 1R X 25 X 10mm Neutral : 1R X 25 X 6mm

-

-

-

... More
Common Metering :

-

-

-

... More
1Nos - 96sqmm Digital type . Energy meter RS 485 Port

-

-

-

... More
1set - Current Transformers (Cast resin type) 250/5A, class 0.5, 10VA

-

-

-

... More
1set - RYB LED type indication lamps for Phase

-

-

-

... More
1set - RGA LED type indication lamps for ON/OFF/Trip

-

-

-

... More
1Set - Control MCB with Neutral link

-

-

-

... More
1Set - Class B+C SPD with control MCB

-

-

-

... More
Outgoings

-

-

-

... More
7 Nos - 125A 4P MCCB wth TM based O/C & S/C Release (25kA) front drive kit with MFM with RS 485 (C.T.125/1A, CLASS 1.0 10VA) & associated protections MCB's, R,Y,B Phase Indicating lamps, auto/manual selector and control circuit as required

-

-

-

... More
Doors: 2mm Body: 2mm Gland: 3mm covers and partitions:1.6mm

-

-

-

... More
Approximate Panel Size - LENGTH - 1.8Mtr X .45Mtr Deepth X 2.1Mtr Height

-

-

-

... More
Note: Refer Tech Specification & SLD for outgoing feeder arrangements

-

-

-

... More
OFFICE PANEL - 5 & 6

2

-

-

... More
Design, Supply, Testing & Commissioning of OFFICE PANEL - 5 & 6 consist of Length - 1.8Mtr X .45Mtr Deepth X 2.1Mtr Height suitable for 415Volts 3Phase 4wire system, fabricated from CRCA sheet steel (Doors:2mm Body:2mm Gland:3mm covers and partitions:1.6mm,) single fronted, free standing, front hinged, rear removable, extendable on both sides, dust & vermin proof, cubicle type, floor mounted, undrilled gland plates at top / bottom, complete with internal wiring, ferrules, name plates, painting etc., conforming to the technical specification for panels & comprising of the following. (Refer enclosed SLD) Tinned Copper Busbar with heat shirnkable colour coded sleeve with SMC Bus bar supports Tinned Copper Busbar with heat shirnkable colour coded sleeve with SMC Bus bar supports Busbar Phase: 1R X 25 X 10mm Neutral : 1R X 25 X 6mm Panel should be fully comply to IEC 61439 part 1 & 2 of type tested assembly (TTA) in addtion to the internal arc test and tempeture rise test at multiple point with nesssry test certificate to be submit

-

-

-

... More
Incomer:

-

-

-

... More
1No - 250A, 36KA,4P MTS associated protections MCB's, R,Y,B Phase Indicating lamps and control circuit as required

-

-

-

... More
1No - 250A, 36KA, 4P MCCB with TM based O/C & S/C Release (25kA) front drive kit & associated protections MCB's, R,Y,B Phase Indicating lamps, auto/manual selector and control circuit as required

-

-

-

... More
Tinned Copper Busbar with heat shirnkable colour coded sleeve with SMC Bus bar supports Busbar Phase: 1R X 25 X 10mm Neutral : 1R X 25 X 6mm

-

-

-

... More
Common Metering :

-

-

-

... More
1Nos - 96sqmm Digital type . Energy meter RS 485 Port

-

-

-

... More
1set - Current Transformers (Cast resin type) 250/5A, class 0.5, 10VA

-

-

-

... More
1set - RYB LED type indication lamps for Phase

-

-

-

... More
1set - RGA LED type indication lamps for ON/OFF/Trip

-

-

-

... More
1Set - Control MCB with Neutral link

-

-

-

... More
1Set - Class B+C SPD with control MCB

-

-

-

... More
Outgoings

-

-

-

... More
7 Nos - 125A 4P MCCB wth TM based O/C & S/C Release (25kA) front drive kit with MFM with RS 485 (C.T.125/1A, CLASS 1.0 10VA) & associated protections MCB's, R,Y,B Phase Indicating lamps, auto/manual selector and control circuit as required

-

-

-

... More
Doors: 2mm Body: 2mm Gland: 3mm covers and partitions:1.6mm

-

-

-

... More
Approximate Panel Size - LENGTH - 1.8Mtr X .45Mtr Deepth X 2.1Mtr Height

-

-

-

... More
Note: Refer Tech Specification & SLD for outgoing feeder arrangements

-

-

-

... More
OFFICE PANEL - 7 & 8

2

-

-

... More
Design, Supply, Testing & Commissioning of OFFICE PANEL - 7 & 8 consist of Length - 1.8Mtr X .45Mtr Deepth X 2.1Mtr Height suitable for 415Volts 3Phase 4wire system, fabricated from CRCA sheet steel (Doors:2mm Body:2mm Gland:3mm covers and partitions:1.6mm,) single fronted, free standing, front hinged, rear removable, extendable on both sides, dust & vermin proof, cubicle type, floor mounted, undrilled gland plates at top / bottom, complete with internal wiring, ferrules, name plates, painting etc., conforming to the technical specification for panels & comprising of the following. (Refer enclosed SLD) Tinned Copper Busbar with heat shirnkable colour coded sleeve with SMC Bus bar supports Tinned Copper Busbar with heat shirnkable colour coded sleeve with SMC Bus bar supports Busbar Phase: 1R X 25 X 10mm Neutral : 1R X 25 X 6mm Panel should be fully comply to IEC 61439 part 1 & 2 of type tested assembly (TTA) in addtion to the internal arc test and tempeture rise test at multiple point with nesssry test certificate to be submit

-

-

-

... More
Incomer:

-

-

-

... More
1No - 250A, 36KA,4P MTS associated protections MCB's, R,Y,B Phase Indicating lamps and control circuit as required

-

-

-

... More
1No - 250A, 36KA, 4P MCCB with TM based O/C & S/C Release (25kA) front drive kit & associated protections MCB's, R,Y,B Phase Indicating lamps, auto/manual selector and control circuit as required

-

-

-

... More
Tinned Copper Busbar with heat shirnkable colour coded sleeve with SMC Bus bar supports Busbar Phase: 1R X 25 X 10mm Neutral : 1R X 25 X 6mm

-

-

-

... More
Common Metering :

-

-

-

... More
1Nos - 96sqmm Digital type . Energy meter RS 485 Port

-

-

-

... More
1set - Current Transformers (Cast resin type) 250/5A, class 0.5, 10VA

-

-

-

... More
1set - RYB LED type indication lamps for Phase

-

-

-

... More
1set - RGA LED type indication lamps for ON/OFF/Trip

-

-

-

... More
1Set - Control MCB with Neutral link

-

-

-

... More
1Set - Class B+C SPD with control MCB

-

-

-

... More
Outgoings

-

-

-

... More
7 Nos - 125A 4P MCCB wth TM based O/C & S/C Release (25kA) front drive kit with MFM with RS 485 (C.T.125/1A, CLASS 1.0 10VA) & associated protections MCB's, R,Y,B Phase Indicating lamps, auto/manual selector and control circuit as required

-

-

-

... More
Doors: 2mm Body: 2mm Gland: 3mm covers and partitions:1.6mm

-

-

-

... More
Approximate Panel Size - LENGTH - 1.8Mtr X .45Mtr Deepth X 2.1Mtr Height

-

-

-

... More
Note: Refer Tech Specification & SLD for outgoing feeder arrangements

-

-

-

... More
OFFICE PANEL - 9 & 10

2

-

-

... More
Design, Supply, Testing & Commissioning of OFFICE PANEL - 9 & 10 consist of Length - 1.8Mtr X .45Mtr Deepth X 2.1Mtr Height suitable for 415Volts 3Phase 4wire system, fabricated from CRCA sheet steel (Doors:2mm Body:2mm Gland:3mm covers and partitions:1.6mm,) single fronted, free standing, front hinged, rear removable, extendable on both sides, dust & vermin proof, cubicle type, floor mounted, undrilled gland plates at top / bottom, complete with internal wiring, ferrules, name plates, painting etc., conforming to the technical specification for panels & comprising of the following. (Refer enclosed SLD) Tinned Copper Busbar with heat shirnkable colour coded sleeve with SMC Bus bar supports Tinned Copper Busbar with heat shirnkable colour coded sleeve with SMC Bus bar supports Busbar Phase: 1R X 25 X 10mm Neutral : 1R X 25 X 6mm Panel should be fully comply to IEC 61439 part 1 & 2 of type tested assembly (TTA) in addtion to the internal arc test and tempeture rise test at multiple point with nesssry test certificate to be submit

-

-

-

... More
Incomer:

-

-

-

... More
1No - 250A, 36KA,4P MTS associated protections MCB's, R,Y,B Phase Indicating lamps and control circuit as required

-

-

-

... More
1No - 250A, 36KA, 4P MCCB with TM based O/C & S/C Release (25kA) front drive kit & associated protections MCB's, R,Y,B Phase Indicating lamps, auto/manual selector and control circuit as required

-

-

-

... More
Tinned Copper Busbar with heat shirnkable colour coded sleeve with SMC Bus bar supports Busbar Phase: 1R X 25 X 10mm Neutral : 1R X 25 X 6mm

-

-

-

... More
Common Metering :

-

-

-

... More
1Nos - 96sqmm Digital type . Energy meter RS 485 Port

-

-

-

... More
1set - Current Transformers (Cast resin type) 250/5A, class 0.5, 10VA

-

-

-

... More
1set - RYB LED type indication lamps for Phase

-

-

-

... More
1set - RGA LED type indication lamps for ON/OFF/Trip

-

-

-

... More
1Set - Control MCB with Neutral link

-

-

-

... More
1Set - Class B+C SPD with control MCB

-

-

-

... More
Outgoings

-

-

-

... More
7 Nos - 125A 4P MCCB wth TM based O/C & S/C Release (25kA) front drive kit with MFM with RS 485 (C.T.125/1A, CLASS 1.0 10VA) & associated protections MCB's, R,Y,B Phase Indicating lamps, auto/manual selector and control circuit as required

-

-

-

... More
Doors: 2mm Body: 2mm Gland: 3mm covers and partitions:1.6mm

-

-

-

... More
Approximate Panel Size - LENGTH - 1.8Mtr X .45Mtr Deepth X 2.1Mtr Height

-

-

-

... More
Note: Refer Tech Specification & SLD for outgoing feeder arrangements

-

-

-

... More
OFFICE PANEL - 11, 12, 13 & 14

4

-

-

... More
Design, Supply, Testing & Commissioning of OFFICE PANEL - 11 TO 14 consist of Length - 1.8Mtr X .45Mtr Deepth X 2.1Mtr Height suitable for 415Volts 3Phase 4wire system, fabricated from CRCA sheet steel (Doors:2mm Body:2mm Gland:3mm covers and partitions:1.6mm,) single fronted, free standing, front hinged, rear removable, extendable on both sides, dust & vermin proof, cubicle type, floor mounted, undrilled gland plates at top / bottom, complete with internal wiring, ferrules, name plates, painting etc., conforming to the technical specification for panels & comprising of the following. (Refer enclosed SLD) Tinned Copper Busbar with heat shirnkable colour coded sleeve with SMC Bus bar supports Tinned Copper Busbar with heat shirnkable colour coded sleeve with SMC Bus bar supports Busbar Phase: 1R X 25 X 10mm Neutral : 1R X 25 X 6mm Panel should be fully comply to IEC 61439 part 1 & 2 of type tested assembly (TTA) in addtion to the internal arc test and tempeture rise test at multiple point with nesssry test certificate to be submit

-

-

-

... More
Incomer:

-

-

-

... More
1No - 250A, 36KA,4P MTS associated protections MCB's, R,Y,B Phase Indicating lamps and control circuit as required

-

-

-

... More
1No - 250A, 36KA, 4P MCCB with TM based O/C & S/C Release (25kA) front drive kit & associated protections MCB's, R,Y,B Phase Indicating lamps, auto/manual selector and control circuit as required

-

-

-

... More
Tinned Copper Busbar with heat shirnkable colour coded sleeve with SMC Bus bar supports Busbar Phase: 1R X 25 X 10mm Neutral : 1R X 25 X 6mm

-

-

-

... More
Common Metering :

-

-

-

... More
1Nos - 96sqmm Digital type . Energy meter RS 485 Port

-

-

-

... More
1set - Current Transformers (Cast resin type) 250/5A, class 0.5, 10VA

-

-

-

... More
1set - RYB LED type indication lamps for Phase

-

-

-

... More
1set - RGA LED type indication lamps for ON/OFF/Trip

-

-

-

... More
1Set - Control MCB with Neutral link

-

-

-

... More
1Set - Class B+C SPD with control MCB

-

-

-

... More
Outgoings

-

-

-

... More
7 Nos - 125A 4P MCCB wth TM based O/C & S/C Release (25kA) front drive kit with MFM with RS 485 (C.T.125/1A, CLASS 1.0 10VA) & associated protections MCB's, R,Y,B Phase Indicating lamps, auto/manual selector and control circuit as required

-

-

-

... More
Doors: 2mm Body: 2mm Gland: 3mm covers and partitions:1.6mm

-

-

-

... More
Approximate Panel Size - LENGTH - 1.8Mtr X .45Mtr Deepth X 2.1Mtr Height

-

-

-

... More
Note: Refer Tech Specification & SLD for outgoing feeder arrangements

-

-

-

... More
PRESSURIZATION PANEL-1 & 2

2

-

-

... More
Design, Supply, Testing & Commissioning of PRESSURIZATION PANEL-1 & 2 consist of Length - 1.8Mtr X .45Mtr Deepth X 2.1Mtr Height suitable for 415Volts 3Phase 4wire system, fabricated from CRCA sheet steel (Doors:2mm Body:2mm Gland:3mm covers and partitions:1.6mm,) single fronted, free standing, front hinged, rear removable, extendable on both sides, dust & vermin proof, cubicle type, floor mounted, undrilled gland plates at top / bottom, complete with internal wiring, ferrules, name plates, painting etc., conforming to the technical specification for panels & comprising of the following. (Refer enclosed SLD) Tinned Copper Busbar with heat shirnkable colour coded sleeve with SMC Bus bar supports Tinned Copper Busbar with heat shirnkable colour coded sleeve with SMC Bus bar supports Busbar Phase: 1R X 50 X 10mm Neutral : 1R X 50 X 6mm Panel should be fully comply to IEC 61439 part 1 & 2 of type tested assembly (TTA) in addtion to the internal arc test and tempeture rise test at multiple point with nesssry test certificate to be submit

-

-

-

... More
Incomer:

-

-

-

... More
1No - 630A, 36KA, 4P 4P Microprocessor based MCCB with front drive kit & associated protections MCB's, R,Y,B Phase Indicating lamps and control circuit as required

-

-

-

... More
Tinned Copper Busbar with heat shirnkable colour coded sleeve with SMC Bus bar supports Busbar Phase: 1R X 50 X 10mm Neutral : 1R X 50 X 6mm

-

-

-

... More
Common Metering :

-

-

-

... More
1Nos - 96sqmm Digital type . Energy meter RS 485 Port

-

-

-

... More
1set - Current Transformers (Cast resin type) 630/5A, class 0.5, 10VA

-

-

-

... More
1set - RYB LED type indication lamps for Phase

-

-

-

... More
1set - RGA LED type indication lamps for ON/OFF/Trip

-

-

-

... More
1Set - Control MCB with Neutral link

-

-

-

... More
1Set - Class B+C SPD with control MCB

-

-

-

... More
Outgoings

-

-

-

... More
2 Nos - 200A 4P MCCB wth TM based O/C & S/C Release (25kA) front drive kit with MFM with RS 485 C.T. 200/1A, CLASS 1.0 10VA & associated protections MCB's, R,Y,B Phase Indicating lamps and control circuit as required

-

-

-

... More
8 Nos - 40A 4P MCCB wth TM based O/C & S/C Release (25kA) front drive kit with MFM with RS 485 (C.T. 40/1A, CLASS 1.0 10VA) & associated protections MCB's, R,Y,B Phase Indicating lamps and control circuit as required

-

-

-

... More
Doors: 2mm Body: 2mm Gland: 3mm covers and partitions:1.6mm

-

-

-

... More
Approximate Panel Size - LENGTH - 1.8Mtr X .45Mtr Deepth X 2.1Mtr Height

-

-

-

... More
Note: Refer Tech Specification & SLD for outgoing feeder arrangements

-

-

-

... More
Supply, Installation, testing & Commissioning of following 4P MCCB breaker with O/L, S/C & E/F protections in suitable enclosure for local isolation with Phase LED lamp, copper busbar & Breaker ON/OFF/Trip (R/Y/B/R/G). Note: For 630A rating breaker shall be provided with floor mounted type enclosure with enough space for termination of incoming & outgoing cables, necessary mounting arrangements as required.

-

-

-

... More
Supply, Installation, testing & Commissioning of 63A Indoor IP42 TM based O/C & S/C Release (25kA) front drive kit Indoor IP42 with Phase LED lamp, copper busbar & Breaker ON/OFF/Trip (R/Y/B/R/G) with shall be provided with floor mounted type enclosure with enough space for termination of incoming & outgoing cables, necessary mounting arrangements as required.

14

-

-

... More
Supply, Installation, testing & Commissioning of 80A TM based O/C & S/C Release (25kA) front drive kit Indoor IP42 with Phase LED lamp, copper busbar & Breaker ON/OFF/Trip (R/Y/B/R/G) with shall be provided with floor mounted type enclosure with enough space for termination of incoming & outgoing cables, necessary mounting arrangements as required.

1

-

-

... More
Supply, Installation, testing & Commissioning of 100A TM based O/C & S/C Release (36kA) front drive kit Indoor IP42 with Phase LED lamp, copper busbar & Breaker ON/OFF/Trip (R/Y/B/R/G) with shall be provided with floor mounted type enclosure with enough space for termination of incoming & outgoing cables, necessary mounting arrangements as required.

6

-

-

... More
Supply, Installation, testing & Commissioning of 400A 36kA - microprpcessor based O/C & S/C Release (36kA) front drive kit Outdoor IP55 with Phase LED lamp, copper busbar & Breaker ON/OFF/Trip (R/Y/B/R/G) with shall be provided with floor mounted type enclosure with enough space for termination of incoming & outgoing cables, necessary mounting arrangements as required.

1

-

-

... More
Supply, Installation, testing & Commissioning of 630A 36kA - microprpcessor based O/C & S/C Release (36kA) front drive kit Indoor IP42 with Phase LED lamp, copper busbar & Breaker ON/OFF/Trip (R/Y/B/R/G) with shall be provided with floor mounted type enclosure with enough space for termination of incoming & outgoing cables, necessary mounting arrangements as required.

1

-

-

... More
Supply, Installation, testing & Commissioning of following Fully Automatic DOL/ Star Delta starters with features like Local/Remote, Auto/Manual & programmable timer for auto operation. Start delta starters shall be provided 5.5kW and above rating. The necessary NO NC shall be provided with BMS compatibility. The space provision for VFD with bypass facility shall be provided wherever it is specified as below. Starter will be used in case of VFD Panel Maintenance/Failure. The AHU panel to be tripped in case of fire, hence necessary contactors for the same to be provided.

-

-

-

... More
Supply, Installation, testing & Commissioning of 37.5 kW Star Delta Starter with connected acessories The necessary NO NC shall be provided with BMS compatibility. The space provision for VFD with bypass facility shall be provided wherever it is specified as below. Starter will be used in case of VFD Panel Maintenance/Failure. The AHU panel to be tripped in case of fire, hence necessary contactors for the same to be provided.

1

-

-

... More
Supply, Installation, testing & Commissioning of 22 kW Star Delta Starter with connected acessories The necessary NO NC shall be provided with BMS compatibility. The space provision for VFD with bypass facility shall be provided wherever it is specified as below. Starter will be used in case of VFD Panel Maintenance/Failure. The AHU panel to be tripped in case of fire, hence necessary contactors for the same to be provided.

1

-

-

... More
Supply, Installation, testing & Commissioning of 15 kW Star Delta Starter with connected acessories The necessary NO NC shall be provided with BMS compatibility. The space provision for VFD with bypass facility shall be provided wherever it is specified as below. Starter will be used in case of VFD Panel Maintenance/Failure. The AHU panel to be tripped in case of fire, hence necessary contactors for the same to be provided.

1

-

-

... More
Supply, Installation, testing & Commissioning of 9.3 kW Star Delta Starter with connected acessories The necessary NO NC shall be provided with BMS compatibility. The space provision for VFD with bypass facility shall be provided wherever it is specified as below. Starter will be used in case of VFD Panel Maintenance/Failure. The AHU panel to be tripped in case of fire, hence necessary contactors for the same to be provided.

1

-

-

... More
Supply, Installation, testing & Commissioning of 7.5 kW Star Delta Starter with connected acessories The necessary NO NC shall be provided with BMS compatibility. The space provision for VFD with bypass facility shall be provided wherever it is specified as below. Starter will be used in case of VFD Panel Maintenance/Failure. The AHU panel to be tripped in case of fire, hence necessary contactors for the same to be provided.

1

-

-

... More
Supply, Installation, testing & Commissioning of 5.5 kW DOL Starter with connected acessories The necessary NO NC shall be provided with BMS compatibility. The space provision for VFD with bypass facility shall be provided wherever it is specified as below. Starter will be used in case of VFD Panel Maintenance/Failure. The AHU panel to be tripped in case of fire, hence necessary contactors for the same to be provided.

1

-

-

... More
Supply, Installation, testing & Commissioning of 3.7 kW DOL Starter with connected acessories The necessary NO NC shall be provided with BMS compatibility. The space provision for VFD with bypass facility shall be provided wherever it is specified as below. Starter will be used in case of VFD Panel Maintenance/Failure. The AHU panel to be tripped in case of fire, hence necessary contactors for the same to be provided.

1

-

-

... More
Supply, Installation, testing & Commissioning of 2.5 kW DOL Starter with connected acessories The necessary NO NC shall be provided with BMS compatibility. The space provision for VFD with bypass facility shall be provided wherever it is specified as below. Starter will be used in case of VFD Panel Maintenance/Failure. The AHU panel to be tripped in case of fire, hence necessary contactors for the same to be provided.

1

-

-

... More
Supply, Installation, testing & Commissioning of 2.2 kW DOL Starter with connected acessories The necessary NO NC shall be provided with BMS compatibility. The space provision for VFD with bypass facility shall be provided wherever it is specified as below. Starter will be used in case of VFD Panel Maintenance/Failure. The AHU panel to be tripped in case of fire, hence necessary contactors for the same to be provided.

1

-

-

... More
Supply, Installation, testing & Commissioning of 0.5 kW DOL Starter with connected acessories The necessary NO NC shall be provided with BMS compatibility. The space provision for VFD with bypass facility shall be provided wherever it is specified as below. Starter will be used in case of VFD Panel Maintenance/Failure. The AHU panel to be tripped in case of fire, hence necessary contactors for the same to be provided.

1

-

-

... More
RISING MAIN Supply, transport to site, unloading, storing, Installation with all necessary supports, testing & commissioning of Sandwich Maintenance free Rising main with Tap off provision to be made in every 0.75 Mtr/1Mtr with Copper conductors Indoor type, dust and vermin proof. System-415V, 3Phase, 4Wire with 100% Neutral and integral 1/2 Earth, Degree of Protection: IP55(Indoor)/IP65(Outdoor). The rate shall be included of wall frame assembly, all the supports, angles etc. Note: The rate shall be included 2RX25X10mm CU. flat for Earth busbar. The maximum hot spot temperature at any point in the bus bar at the continuous rated current shall not exceed 55 deg above the maximum ambient temperature of 40 deg. Tool Kit 1 set to be included in the offer.

-

-

-

... More
Supply Installation testing commissioning of BBT Straight Run with following details Conductors : Copper Rating : 1250 A,4P 50kA SC for 1 sec Configuration : 3P4W (100% N) Insulation:Class-F IP Rating : IP55 Enclosure : GI 1.6mm thickness, Impulse Withstand Voltage : 8kV Paint Shade : RAL7032 Epoxy Powder Coating

118

-

-

... More
Supply Installation testing commissioning of End Covers

4

-

-

... More
Supply Installation testing commissioning of 1250 A Copper Flexibles

4

-

-

... More
Supply Installation testing commissioning of Terminal flange with adopter box and extention of bus bar for terminating the bus duct.

4

-

-

... More
Supply Installation testing commissioning of Accessories ( including spring hangers, fixing clips, floor seal, Etc.,)

8

-

-

... More
Supplying, installation, testing & commisioning of 1250A 50kA 4P EDO ACB with O/C, S/C, E/F release SC for 1 sec End Feed Unit for the existing Sandwich type rising mains for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply made with 1.6mm thick steel sheet enclosure (IP54) duly powder coated with Cu Busbar Arrangement Complete with Copper busbar , Indication lamps , Multi function meter for ACB with bottom Busduct entry and top Busduct outgoing provision and necessary joints including clamping brackets, angle iron bracket, steel fasteners, connecting to earthing system, with all fixing accessories etc. as required .

4

-

-

... More
Supplying, installation, testing & commisioning of Tap-off boxes with 160A, 36kA 4P MCCB with Dual Source Energy Meter with RS 485 & related CTS on the existing Sandwich type rising mains for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply made with 1.6mm thick sheet steel enclosure (IP54) duly powder coated with MCCB complete etc. as required Provision to be made for BMS Integration. Separate cable alley need to be considered for cable termination considering the cable bending radius.

14

-

-

... More
Supplying, installation, testing & commisioning of Tap-off boxes with 200A, 36kA 4P MCCB with Dual Source Energy Meter with RS 485 & related CTS on the existing Sandwich type rising mains for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply made with 1.6mm thick sheet steel enclosure (IP54) duly powder coated with MCCB complete etc. as required Provision to be made for BMS Integration. Separate cable alley need to be considered for cable termination considering the cable bending radius.

1

-

-

... More
Supplying, installation, testing & commisioning of Tap-off boxes with 250A, 36kA 4P MCCB with Dual Source Energy Meter with RS 485 & related CTS on the existing Sandwich type rising mains for use on 3 phase 4 wire 415 volts, 50Hz A.C. supply made with 1.6mm thick sheet steel enclosure (IP54) duly powder coated with MCCB complete etc. as required Provision to be made for BMS Integration. Separate cable alley need to be considered for cable termination considering the cable bending radius.

14

-

-

... More
BUSDUCTS Supply, transport to site, unloading, storing, Installation with all necessary supports, testing & commissioning of Sandwich Maintenance free busduct with Copper conductors Indoor/Outdoor type, dust and vermin proof transformer/switchgear ends & necessary locations as directed at the site from floor, ceiling, wall etc., The bus duct shall have suitable flange at ends to connect with Transformer, Main LT Panel. System-415V, 3Phase, 4Wire with 100% Neutral and integral 1/2 Earth, Degree of Protection: IP55(Indoor) & IP65 with canopy (Outdoor). The rate shall be included End box, flange connection, wall frame assembly, Phase cross chamber, horizontal & vertical connection, all required bends, end feed, adaptor boxes, flexible links with lugs for termination at the transformer end and LT panel end, supports, angles etc., Note: The rate shall be included 2RX25X10mm Cu. flat for Earth busbar. The maximum hot spot temperature at any point in the bus bar at the continuous rated current shall not exceed 55deg above the maximum ambient temperature of 40 deg. Connectors between the Indoor & Outdoor Busducts need to be considered. Supply of 415V Sandwich construction Busbar trunking system with Multilayer Class-F insulation Conductors : Copper Rating : 4000A Configuration : 3P4W (100% N) IP Rating : IP55/65 Enclosure : GI 1.6mm thickness Impulse Withstand Voltage : 8kV Paint Shade : RAL7032 Epoxy Powder Coating

-

-

-

... More
Supply, transport to site, unloading, storing, Installation with all necessary supports, testing & commissioning of Straight Run - IP55/65 (Transformer and DG)

44

-

-

... More
Supply, transport to site, unloading, storing, Installation with all necessary supports, testing & commissioning of Vertical Bend 90 Degrees Bend

9

-

-

... More
Supply, transport to site, unloading, storing, Installation with all necessary supports, testing & commissioning of Horizontal 90 Degrees Bend

9

-

-

... More
Supply, transport to site, unloading, storing, Installation with all necessary supports, testing & commissioning of Conversion Bend/Box - From Horizontal to vertical busduct and from vertical to Horizontal busduct as per drawing with flexibles and all accessories

6

-

-

... More
Supply, transport to site, unloading, storing, Installation with all necessary supports, testing & commissioning of Terminal flange with adopter box and extention of bus bar for terminating the bus duct.

13

-

-

... More
Supply, transport to site, unloading, storing, Installation with all necessary supports, testing & commissioning of accessories ( like Interconnecting bus bars rubber bellows, Flexible couplers, wall frame assembly, Etc.,)

7

-

-

... More
Supply, transport to site, unloading, storing, Installation with all necessary supports, testing & commissioning of Phase cross over

2

-

-

... More
Supply, transport to site, unloading, storing, Installation with all necessary supports, testing & commissioning of Sandwich Maintenance free busduct with Copper conductors Indoor/Outdoor type, dust and vermin proof transformer/switchgear ends & necessary locations as directed at the site from floor, ceiling, wall etc., The bus duct shall have suitable flange at ends to connect with Transformer, Main LT Panel. System-415V, 3Phase, 4Wire with 100% Neutral and integral 1/2 Earth, Degree of Protection: IP55(Indoor) & IP65 with canopy (Outdoor). The rate shall be included End box, flange connection, wall frame assembly, Phase cross chamber, horizontal & vertical connection, all required bends, end feed, adaptor boxes, flexible links with lugs for termination at the transformer end and LT panel end, supports, angles etc., Note: The rate shall be included 2RX50X10mm GI. flat for Earth busbar. The maximum hot spot temperature at any point in the bus bar at the continuous rated current shall not exceed 55deg above the maximum ambient temperature of 40 deg. Connectors between the Indoor & Outdoor Busducts need to be considered.

-

-

-

... More
Supply Installation testing commissioning of BBT Straight Run with following details Conductors : Copper Rating : 2500 A,4P 50kA SC for 1 sec Configuration : 3P4W (100% N) Insulation:Class-F IP Rating : IP55 Enclosure : GI 1.6mm thickness, Impulse Withstand Voltage : 8kV Paint Shade : RAL7032 Epoxy Powder Coating for APFC Panel

105

-

-

... More
Supply, transport to site, unloading, storing, Installation with all necessary supports, testing & commissioning of Vertical Bend 90 Degrees Bend

17

-

-

... More
Supply, transport to site, unloading, storing, Installation with all necessary supports, testing & commissioning of Horizontal 90 Degrees Bend

5

-

-

... More
Conversion Bend/Box - From Horizontal to vertical busduct and from vertical to Horizontal busduct as per drawing with flexibles and all accessories

17

-

-

... More
Supply, transport to site, unloading, storing, Installation with all necessary supports, testing & commissioning of Terminal flange with adopter box and extention of bus bar for terminating the bus duct.

16

-

-

... More
Supply, transport to site, unloading, storing, Installation with all necessary supports, testing & commissioning of Accessories ( like Interconnecting bus bars rubber bellows, Flexible couplers, wall frame assembly, Etc.,)

8

-

-

... More
Supply, transport to site, unloading, storing, Installation with all necessary supports, testing & commissioning of Phase cross over

2

-

-

... More
MCB DISTRIBUTION BOARDS Supply, Installation, Testing and Commissioning of MCB Distribution board as per approved installation dwgs. Wall mounted MCB DBs with MS wire way box on top / bottom & on sides. MCBs shall be rated for 10kA with current limiting feature. Dummy ways to be covered with blank plates. All out going ways shall be labelled & laminated. Enclosure:1.2mm CRCA Sheet Steel, Powder Coated Door : Double Door Protection : IP 42 Cable Entry : Top & Bottom For UPS distribution RCCB's shall be harmonic resistant (HI/SI type) Bus bar : Shall be tinned Copper and 200% rating for UPS DB Neutral Link MCB's : 10kA 'C' Curve for Lighting & Raw power, 10kA 'D' Curve for UPS Distribution Note: 1) Separate Earth bus/Neutral bus for each phase 2) Each Circuit shall have yellow ferrules with circuit number 3) Accessories required for installation of DB's on Wall/Column/Gyp Board shall be considered 4) DB's shall be covered with powder coated (paint should match with DB Color) wire ways all around and up to ceiling to receive incoming circuits, how ever raceway shall be considered as a separate items 5) Laminated A3 OR A4 size SLD copy shall be pasted inside DB door 6) Safe shroud for Neutral link shall be provided

-

-

-

... More
Supply, Installation, Testing and Commissioning of 7 segment three phase, phase segregated, compartmentalised 6 way MCBDB Double door type, IP 42 powder coated comprising of "C" curve MCB's for LIGHTING DB. Including all fixing hardwares Incomer - 40A 4P MCB - 1 No Phase Incomer - 40A 30mA DP RCBO - 3Nos Outgoings - 10A SP MCB - 18 Nos Cable Adaptor box - TOP & BOTTEM Double earth connections and Including all interconnections & other associated fixing accessories etc as reqd as per the site conditions.

32

-

-

... More
Supply, Installation, Testing and Commissioning of 7 segment three phase, phase segregated, compartmentalised 8 way MCBDB Double door type, IP 42 powder coated comprising of "C" curve MCB's for LIGHTING DB. Including all fixing hardwares Incomer - 40A 4P MCB - 1 No Phase Incomer - 40A 30mA DP RCBO - 3Nos Outgoings - 10A SP MCB - 24 Nos Cable Adaptor box - TOP & BOTTEM Double earth connections and Including all interconnections & other associated fixing accessories etc as reqd as per the site conditions.

8

-

-

... More
Supply, Installation, Testing and Commissioning of Single phase, compartmentalised 12 way SPNDB Single door type, IP 42 powder coated comprising of "D" curve MCB's for LDB. Phase Incomer - 40A 30mA DP RCBO - 1Nos Outgoings - 10A SP MCB - 10 Nos Cable Adaptor box - TOP & BOTTEM Double earth connections and Including all interconnections & other associated fixing accessories etc as reqd as per the site conditions.

4

-

-

... More
Supply, Installation, Testing and Commissioning of 7 segment three phase, phase segregated, compartmentalised 8 way MCBDB Double door type, IP 42 powder coated comprising of "C" curve MCB's for POWER DB. Incommer - 63A 4P MCB - 1 No Phase Incomer - 40A 100mA DP RCBO - 3Nos Outgoings - 16A SP MCB - 24Nos Cable Adaptor box - TOP & BOTTEM Double Earth connections and Including all interconnections & other associated fixing accessories etc as reqd as per the site conditions.

2

-

-

... More
Supply, Installation, Testing and Commissioning of 7 segment three phase, phase segregated, compartmentalised 6 way MCBDB Double door type, IP 42 powder coated comprising of "C" curve MCB's for POWER DB. Incomer - 40A 4P MCB - 1 No Phase Incomer - 40A 100mA DP RCBO - 3Nos Outgoings - 16A SP MCB - 18Nos Double earth connections and Including all interconnections & other associated fixing accessories etc as reqd as per the site conditions.

30

-

-

... More
Supply, Installation, Testing and Commissioning of Single phase ,compartmentalised 12 way SPNDB Single door type, IP 42 powder coated comprising of "D" curve MCB's for POWER DB. Phase Incomer - 40A 30mA DP RCBO - 1Nos Outgoings - 10A SP MCB - 8 Nos Double earth connections and Including all interconnections & other associated fixing accessories etc as reqd as per the site conditions.

2

-

-

... More
Supply, Installation, Testing and Commissioning of Single phase ,compartmentalised 12 way SPNDB Single door type, IP 42 powder coated comprising of "D" curve MCB's forr EMERGENCY LDB. Phase Incomer - 40A 30mA DP RCBO - 1Nos Outgoings - 10A SP MCB - 8 Nos Double earth connections and Including all interconnections & other associated fixing accessories etc as reqd as per the site conditions.

30

-

-

... More
Supply, Installation, Testing and Commissioning of 7 segment three phase, phase segregated, compartmentalised 6 way MCBDB Double door type, IP 42 powder coated comprising of "D" curve MCB's for UPSDB. Incomer - 40A 4P MCB - 1 No Phase Incomer - 32A 100mA DP RCBO - 3Nos Outgoings - 16A SP MCB 'D' Curve - 18Nos Cable Adaptor box - TOP & BOTTEM Double earth connections and Including all interconnections & other associated fixing accessories etc as reqd as per the site conditions.

3

-

-

... More
Supply, Installation, Testing and Commissioning of Single phase ,compartmentalised 12 way SPNDB Single door type, IP 42 powder coated comprising of "D" curve MCB's for UPSDB. Phase Incomer - 40A 30mA DP RCBO - 1Nos Outgoings - 10A SP MCB 'D' Curve - 8 Nos Double earth connections and Including all interconnections & other associated fixing accessories etc as reqd as per the site conditions.

1

-

-

... More
Supply, Installation, Testing and Commissioning of Three phase, 4WAY VTPN MCCB DB Double door type, IP 42 powder coated comprising of "C" curve MCB's for TENENT VTPN DB Incomer - 125A 4P MCCB (DPX) - 1 No Outgoings - 63A TP MCB - 4 Nos 1 set of MFM (Multi Function Meter) Cable Adaptor box - TOP & BOTTEM Double earth connections and Including all interconnections & other associated fixing accessories etc as reqd as per the site conditions.

42

-

-

... More
Supply, Installation, Testing and Commissioning of Three phase, 4WAY VTPN MCB DB Double door type, IP 42 powder coated comprising of "C" curve MCB's for Lift VTPN DB Incomer - 63A 4P RCBO 100mA - 1 No Outgoings - 63A TP MCB - 2Nos. & 6A 32A TP MCB - 2Nos. Double earth connections and Including all interconnections & other associated fixing accessories etc as reqd as per the site conditions.

2

-

-

... More
Supply, Installation, Testing and Commissioning of Three phase, 4WAY VTPN MCB DB Double door type, IP 42 powder coated comprising of "C" curve MCB's for MLDB (Main Lighting DB) VTPN DB Incomer - 63A 4P RCBO 30mA - 1 No Outgoings - 40A TP MCB - 4Nos. Including all interconnections and other associated fixing accessories etc as reqd as per the site conditions.

15

-

-

... More
Supply, Installation, Testing and Commissioning of Three phase, Fabricated Outdoor type DB, TPN Vertical bus bar type, Double door , IP 55 powder coated DB comprising of "C" curve MCB's for External Lighting Incomer - 63A 4P MCCB with 63A TP Power contact, 24h timer, ON, OFF Indication lamp, Push button (Start/Stop), 1No. of Auto/Manual selector switch with TB & necessary control protection etc. - 1 No Outgoings - 32A/25A TP MCB - 8Nos. Including all interconnections and other associated fixing accessories etc as reqd as per the site conditions.

1

-

-

... More
Supply, Installation, Testing and Commissioning of Three phase, Fabricated type DB, TPN Vertical bus bar type, Double door , IP 64 powder coated DB comprising of "C" curve MCB's for 2 WHEELER EV CHARGING DB with MS angle iron frame mounting Incomer - 125A 4P MCCB - 1 No Outgoings - 16A SP MCB - 24Nos. Including all interconnections and other associated fixing accessories etc as reqd as per the site conditions.

2

-

-

... More
Supply, Installation, Testing and Commissioning of Three phase, Fabricated type DB, TPN Vertical bus bar type, Double door , IP 64 powder coated DB comprising of "C" curve MCB's for 4 WHEELER EV CHARGING DB with MS angle iron frame mounting Incomer - 250A 4P MCCB - 1 No Outgoings - 63A SP MCB - 24Nos. Including all interconnections and other associated fixing accessories etc as reqd as per the site conditions.

2

-

-

... More
LT CABLES & TERMINATIONS NOTES :- The Quantities (mtrs) given in the BOQ are only approximate and the contractor has to take actual measurements at site for the exact quantities of materials required before purchase of materials required for the work. Supply, laying, testing and commissioning of the following sizes of 1.1KV grade Aluminium / Copper Conductor armoured power cables Insulation of XLPE laid on trays, ceilings, walls trenches, ground etc., with necessary clamps, cable ties, fasteners, identification tags, cable marking as required. The Cost of sand, bricks and excavation should not be included in the rate quoted and measured separately. All cables shall be FRLS.

-

-

-

... More
Supply and laying of 3 1/2C X 400 sqmm A2XFY cable on Wall / Trench with MS clamps

250

-

-

... More
Supply and laying of 3 1/2C X 300 sqmm A2XFY cable on Wall / Trench with MS clamps

6500

-

-

... More
Supply and laying of 3 1/2C X 240 sqmm A2XFY cable on Wall / Trench with MS clamps

2500

-

-

... More
Supply and laying of 3 1/2C X 185 sqmm A2XFY cable on Wall / Trench with MS clamps

1870

-

-

... More
Supply and laying of 3 1/2C X 150 sqmm A2XFY cable on Wall / Trench with MS clamps

160

-

-

... More
Supply and laying of 3 1/2C X 120 sqmm A2XFY cable on Wall / Trench with MS clamps

540

-

-

... More
Supply and laying of 3 1/2 C X 95 sqmm A2XFY cable on Wall / Trench with MS clamps

240

-

-

... More
Supply and laying of 3 1/2 C X 70 sqmm A2XFY cable on Wall / Trench with MS clamps

390

-

-

... More
Supply and laying of 3 1/2C X 50 sqmm A2XFY cable on Wall / Trench with MS clamps

100

-

-

... More
Supply and laying of 3 1/2C X 35 sqmm A2XFY cable on Wall / Trench with MS clamps

3448

-

-

... More
Supply and laying of 4C X 25 sqmm A2XFY cable on Wall / Trench with MS clamps

2340

-

-

... More
Supply and laying of 4C X 16 sqmm A2XFY cable on Wall / Trench with MS clamps

3250

-

-

... More
Supply and laying of 3C X 50 sqmm A2XFY cable on Wall / Trench with MS clamps

10

-

-

... More
Supply and laying of 3C X 16 sqmm A2XFY cable on Wall / Trench with MS clamps

10

-

-

... More
Supply and laying of 3CX2.5sq.mm 2XWY cable on Wall / Trench with MS clamps

10

-

-

... More
Supply and laying of 3CX4sq.mm 2XWY cable on Wall / Trench with MS clamps

10

-

-

... More
Supply and laying of 3CX6sq.mm 2XWY cable on Wall / Trench with MS clamps

630

-

-

... More
Supply and laying of 3CX10sq.mm 2XWY cable on Wall / Trench with MS clamps

84

-

-

... More
Supply and laying off 3CX16sq.mm 2XWY cable on Wall / Trench with MS clamps

1722

-

-

... More
Supply and laying of 3CX25sq.mm 2XWY cable on Wall / Trench with MS clamps

79

-

-

... More
Supply and laying of 3CX35sq.mm 2XWY cable on Wall / Trench with MS clamps

252

-

-

... More
Supply and laying of 4CX6sq.mm 2XWY cable on Wall / Trench with MS clamps

2699

-

-

... More
Supply and laying of 4CX10sq.mm 2XWY cable on Wall / Trench with MS clamps

615

-

-

... More
Supply and laying of 4CX16sq.mm 2XWY cable on Wall / Trench with MS clamps

1176

-

-

... More
Supply and laying of4CX25sq.mm 2XWY cable on Wall / Trench with MS clamps

10

-

-

... More
Supply and laying of 3CX50sq.mm 2XY cable on Wall / Trench with MS clamps

10

-

-

... More
Supply and laying of 3CX16sq.mm 2XY cable on Wall / Trench with MS clamps

210

-

-

... More
Supply and laying of 3CX10sq.mm 2XY cable on Wall / Trench with MS clamps

10

-

-

... More
Supply and laying of 3CX4sq.mm 2XY cable on Wall / Trench with MS clamps

79

-

-

... More
Supply and laying of 1C X 10 sqmm Copper flexible cable cable on Wall / Trench with MS clamps

10

-

-

... More
Supply and laying of 1C X 16 sqmm Copper flexible cable cable on Wall / Trench with MS clamps

373

-

-

... More
Supply and laying of 1C X 25 sqmm Copper flexible cable cable on Wall / Trench with MS clamps

284

-

-

... More
Supply and laying of 4CX2.5 sq.mm 2XWY cable on Wall / Trench with MS clamps

10

-

-

... More
Fire Survival cables: Supply, loading, transportation unloading and storages at site , shifting from storage place to site of following sizes of XLPE insulated PVC sheathed,FireSurvival (FS), Aluminium/Copper conductor armoured power cable of 1.1 KV grade conforming to IS amended upto date and as per specifications.All cables shall be tagged.

-

-

-

... More
Supply and laying of 3 1/2C X 300 sqmm Al. FS cable cable on Wall / Trench with MS clamps

578

-

-

... More
Supply and laying of 3 1/2C X 240 sqmm Al. FS cable cable on Wall / Trench with MS clamps

609

-

-

... More
Supply and laying of 3 1/2C X 185 sqmmAl. FS cable cable on Wall / Trench with MS clamps

10

-

-

... More
Supply and laying of 3 1/2C X 150 sqmm Al. FS cable cable on Wall / Trench with MS clamps

273

-

-

... More
Supply and laying of 3 1/2C X 120 sqmm Al. FS cable cable on Wall / Trench with MS clamps

158

-

-

... More
Supply and laying of 3 1/2C X 50 sqmm Al. FS cable cable on Wall / Trench with MS clamps

10

-

-

... More
Supply and laying of 3 1/2C X 35 sqmm Al. FS cable cable on Wall / Trench with MS clamps

158

-

-

... More
Supply and laying of 4C X 25 sqmm Cu. FS cable cable on Wall / Trench with MS clamps

10

-

-

... More
Supply and laying of 4C X 16 sqmm Cu. FS cable cable on Wall / Trench with MS clamps

10

-

-

... More
Supply and laying of 4C X 10 sqmm Cu. FS cable cable on Wall / Trench with MS clamps

10

-

-

... More
Supply and laying of 4C X 6 sqmm Cu. FS cable cable on Wall / Trench with MS clamps

10

-

-

... More
Supply & end termination of following AL/CU armoured power cables with necessary double compression brass glands, AL/CU. terminal sockets, insulation tapes, fasteners, earthing clips & connecting the clip to main earth bus with suitable bare copper wire complete accessories as required; all outdoor double compression and indoor single compression.

-

-

-

... More
Supply and fixing of brass cable gland and aluminium armoured cable with necessary aluminium cable sockets by crimping etc for 3 1/2C X 400 sqmm A2XFY with earth connection

48

-

-

... More
Supply and fixing of brass cable gland and aluminium armoured cable with necessary aluminium cable sockets by crimping etc for 3 1/2C X 300 sqmm A2XFY with earth connection

88

-

-

... More
Supply and fixing of brass cable gland and aluminium armoured cable with necessary aluminium cable sockets by crimping etc for 3 1/2C X 240 sqmm A2XFY with earth connection

16

-

-

... More
Supply and fixing of brass cable gland and aluminium armoured cable with necessary aluminium cable sockets by crimping etc for3 1/2C X 185 sqmm A2XFY with earth connection

10

-

-

... More
Supply and fixing of brass cable gland and aluminium armoured cable with necessary aluminium cable sockets by crimping etc for 3 1/2C X 150 sqmm A2XFY with earth connection

6

-

-

... More
Supply and fixing of brass cable gland and aluminium armoured cable with necessary aluminium cable sockets by crimping etc for 3 1/2C X 120 sqmm A2XFY with earth connection

12

-

-

... More
Supply and fixing of brass cable gland and aluminium armoured cable with necessary aluminium cable sockets by crimping etc for 3 1/2 C X 95 sqmm A2XFY with earth connection

4

-

-

... More
Supply and fixing of brass cable gland and aluminium armoured cable with necessary aluminium cable sockets by crimping etc for 3 1/2 C X 70 sqmm A2XFY with earth connection

8

-

-

... More
Supply and fixing of brass cable gland and aluminium armoured cable with necessary aluminium cable sockets by crimping etc 3 1/2C X 50 sqmm A2XFY with earth connection

4

-

-

... More
Supply and fixing of brass cable gland and aluminium armoured cable with necessary aluminium cable sockets by crimping etc for 3 1/2C X 35 sqmm A2XFY with earth connection

134

-

-

... More
Supply and fixing of brass cable gland and aluminium armoured cable with necessary aluminium cable sockets by crimping etc for 4C X 25 sqmm A2XFY with earth connection

62

-

-

... More
Supply and fixing of brass cable gland and aluminium armoured cable with necessary aluminium cable sockets by crimping etc for 4C X 16 sqmm A2XFY with earth connection

102

-

-

... More
Supply and fixing of brass cable gland and aluminium armoured cable with necessary aluminium cable sockets by crimping etc for 3C X 50 sqmm A2XFY with earth connection

2

-

-

... More
Supply and fixing of brass cable gland and aluminium armoured cable with necessary aluminium cable sockets by crimping etc for 3C X 16 sqmm A2XFY with earth connection

2

-

-

... More
Supply and fixing of brass cable gland and aluminium armoured cable with necessary aluminium cable sockets by crimping etc for 3CX2.5sq.mm 2XWY with earth connection

2

-

-

... More
Supply and fixing of brass cable gland and aluminium armoured cable with necessary aluminium cable sockets by crimping etc for 3CX4sq.mm 2XWY with earth connection

2

-

-

... More
Supply and fixing of brass cable gland and aluminium armoured cable with necessary aluminium cable sockets by crimping etc for 3CX6sq.mm 2XWY with earth connection

34

-

-

... More
Supply and fixing of brass cable gland and aluminium armoured cable with necessary aluminium cable sockets by crimping etc for 3CX10sq.mm 2XWY with earth connection

4

-

-

... More
Supply and fixing of brass cable gland and aluminium armoured cable with necessary aluminium cable sockets by crimping etc for 3CX16sq.mm 2XWY with earth connection

48

-

-

... More
Supply and fixing of brass cable gland and aluminium armoured cable with necessary aluminium cable sockets by crimping etc for 3CX25sq.mm 2XWY with earth connection

2

-

-

... More
Supply and fixing of brass cable gland and aluminium armoured cable with necessary aluminium cable sockets by crimping etc for 3CX35sq.mm 2XWY with earth connection

14

-

-

... More
Supply and fixing of brass cable gland and aluminium armoured cable with necessary aluminium cable sockets by crimping etc for 4CX6sq.mm 2XWY with earth connection

74

-

-

... More
Supply and fixing of brass cable gland and aluminium armoured cable with necessary aluminium cable sockets by crimping etc for 4CX10sq.mm 2XWY with earth connection

24

-

-

... More
Supply and fixing of brass cable gland and aluminium armoured cable with necessary aluminium cable sockets by crimping etc for 4CX16sq.mm 2XWY with earth connection

30

-

-

... More
Supply and fixing of brass cable gland and aluminium armoured cable with necessary aluminium cable sockets by crimping etc for 4CX25sq.mm 2XWY with earth connection

2

-

-

... More
Supply and fixing of brass cable gland and aluminium armoured cable with necessary aluminium cable sockets by crimping etc for 3CX50sq.mm 2XY with earth connection

2

-

-

... More
Supply and fixing of brass cable gland and aluminium armoured cable with necessary aluminium cable sockets by crimping etc for 3CX16sq.mm 2XYwith earth connection

22

-

-

... More
Supply and fixing of brass cable gland and aluminium armoured cable with necessary aluminium cable sockets by crimping etc for 3CX10sq.mm 2XY with earth connection

2

-

-

... More
Supply and fixing of brass cable gland and aluminium armoured cable with necessary aluminium cable sockets by crimping etc for 3CX4sq.mm 2XY with earth connection

6

-

-

... More
Supply and fixing of brass cable gland and aluminium armoured cable with necessary aluminium cable sockets by crimping etc for 1C X 10 sqmm Copper flexible cable with earth connection

2

-

-

... More
Supply and fixing of brass cable gland and aluminium armoured cable with necessary aluminium cable sockets by crimping etc for 1C X 16 sqmm Copper flexible cable with earth connection

58

-

-

... More
Supply and fixing of brass cable gland and aluminium armoured cable with necessary aluminium cable sockets by crimping etc for 1C X 25 sqmm Copper flexible cable with earth connection

38

-

-

... More
Supply and fixing of brass cable gland and aluminium armoured cable with necessary aluminium cable sockets by crimping etc for 4CX2.5sq.mm 2XWY with earth connection

2

-

-

... More
Supply and fixing of brass cable gland and aluminium armoured cable with necessary aluminium cable sockets by crimping etc for 4C X 10 sqmm A2XFY with earth connection

2

-

-

... More
Supply and fixing of brass cable gland and aluminium armoured cable with necessary aluminium cable sockets by crimping etc for 4C X 6 sqmm 2XWY with earth connection

2

-

-

... More
Fire Survival cable End Termination Supplying and making Flame Proof end termination with brass double compression Flame Proof gland and Aluminium/ copper lugs for following size of PVC insulated and PVC sheathed / XLPE copper conductor cable of 1.1 KV grade as required

-

-

-

... More
Supply and fixing of brass cable gland and aluminium armoured cable with necessary aluminium cable sockets by crimping etc for 3 1/2C X 300 sqmm Al. FS cable with earth connection

2

-

-

... More
Supply and fixing of brass cable gland and aluminium armoured cable with necessary aluminium cable sockets by crimping etc for3 1/2C X 240 sqmm Al. FS cable with earth connection

2

-

-

... More
Supply and fixing of brass cable gland and aluminium armoured cable with necessary aluminium cable sockets by crimping etc for 3 1/2C X 185 sqmmAl. FS cable with earth connection

2

-

-

... More
Supply and fixing of brass cable gland and aluminium armoured cable with necessary aluminium cable sockets by crimping etc for 3 1/2C X 150 sqmm Al. FS cable with earth connection

2

-

-

... More
Supply and fixing of brass cable gland and aluminium armoured cable with necessary aluminium cable sockets by crimping etc for 3 1/2C X 120 sqmm Al. FS cable with earth connection

2

-

-

... More
Supply and fixing of brass cable gland and aluminium armoured cable with necessary aluminium cable sockets by crimping etc for 3 1/2C X 50 sqmm Al. FS cable with earth connection

2

-

-

... More
Supply and fixing of brass cable gland and aluminium armoured cable with necessary aluminium cable sockets by crimping etc for 3 1/2C X 35 sqmm Al. FS cable with earth connection

2

-

-

... More
Supply and fixing of brass cable gland and aluminium armoured cable with necessary aluminium cable sockets by crimping etc for 4C X 25 sqmm Cu. FS cable with earth connection

2

-

-

... More
Supply and fixing of brass cable gland and aluminium armoured cable with necessary aluminium cable sockets by crimping etc forf 4C X 16 sqmm Cu. FS cable with earth connection

2

-

-

... More
Supply and fixing of brass cable gland and aluminium armoured cable with necessary aluminium cable sockets by crimping etc for 4C X 10 sqmm Cu. FS cable with earth connection

2

-

-

... More
Supply and fixing of brass cable gland and aluminium armoured cable with necessary aluminium cable sockets by crimping etc for 4C X 6 sqmm Cu. FS cable with earth connection

2

-

-

... More
LUMINAIRES Supply & Installation, Testing and Commissioning of following Light fixtures and lamps with all accessories, fixing on the wall / ceiling/false ceiling with wooden blocks, screws, hardware's, suspended chain hooks as required as per the site conditions (including the earthing of fixture) Light fixtures complete with accessories like control gear, Drivers, Energy efficient high lumen output LED's, etc., Light Fixtures quoted rate shall include mounting bracket and lamps . Gripple/steel ropes need to be considered for suspended light fixtures Note: Lamp Colour tempature (CCT) shall be as approved by Architect / client/ Consultant. Vendor shall consider necessary fixing hardware like supporting rods, angles etc and components to install light fixtures. The hardware viz., anchor fasteners, suspending GI chains, down rods will not be measured seperately. Vendor shall assume a minimum suspension length of 1.5 Mtrs

-

-

-

... More
Supply & Installation, Testing and Commissioning of 15W, High efficient recess mounted LED round downlighter with white powder coated, pressure die cast aluminium housing. High transmittivity PS diffuser provides soft light. CRI80, IP20, Ambient temp-0 to 45DegC, CCT - 5700K, 50,000 hrs @ L70 life. Driver efficiency85%, THD10%, Powerfactor0.9, Surge protection-2 kV, Multistage Isolated Constant Current-Constant Voltage operated driver with range 90-265V AC and Safety Extra Low Voltage Safe level60V DC as per IEC standard.IP40(Housing),IP20(Driver). Luminaire lumen ≥ 1500 lm. (100 lm/W) - Cutout Dia-ø145mm.

63.8

-

-

... More
Supply & Installation, Testing and Commissioning of 20W High efficient LED batten surface/wall mounted Specially designed extruded Aluminium housing with PC diffuser. In-built electronic driver duly wired up to terminal block.IP20, CRI 80, Temperature range-0 to 50DegC, Driver efficiency86%, Power factor0.95, CCT - 6500K, THD10%, Surge protection 2kV, 50000 burning hours as per L70 Criteria, Multistage Isolated Constant Current operated driver with range 150-270V AC and Safety Extra Low Voltage Safe level60V DC as per IEC standard. Luminaire lumen ≥ 2000 lumens (100 lm/W).

260.4

-

-

... More
Supply & Installation, Testing and Commissioning of Integral, SMD LED, IP40, 40W Surface Mounted LED Batten with System efficacy of more than 110 lm/W. LED luminaire shall have sleek designwith Extruded Aluminum Section. The luminaire shall have High Optically Efficient Polycarbonate Diffuser for Uniform illumination and wider light distribution. Screwless Design ensures ease of maintenance. The LEDs used should be with CCT of 5700 K and CRI of Minimum 80. LED Driver shall be Isolated type, Constant Current topology driver with proper heat sink for heat dissipation suitable to operate in input voltage range of 150V to 270V (nominal rated voltage – 240V) with 3 KV internal surge protection, Power factor greater than 0.95 and total harmonic distortion (THD) of less than 10% should be integral to the luminaire.

149.1

-

-

... More
Supply & Installation, Testing and Commissioning of 18W, High efficient recess mounted LED round downlighter with white powder coated, pressure die cast aluminium housing. High transmittivity PS diffuser provides soft light. CRI80, IP20, Ambient temp-0 to 45DegC, CCT - 5700K, 50,000 hrs @ L70 life.Driver efficiency85%, THD10%, Powerfactor0.9, Surge protection-2 kV, Multistage Isolated Constant Current-Constant Voltage operated driver with range 90-265V AC and Safety Extra Low Voltage Safe level60V DC as per IEC standard.IP40(Housing),IP20(Driver). Luminaire lumen ≥ 1800 lm. (100 lm/W) - Cutout Dia-ø145mm.

533.4

-

-

... More
Supply & Installation, Testing and Commissioning of Non-integral flexible 15W LED strip light, Solid state high brightness SMD led chips, IP20 protected LED Flexible light including driver. The strip can be cut at marked intervals to suit the desired length. CRI80, Luminaire lumen ≥ 720lm.CCT-6500K.

693

-

-

... More
Supply & Installation, Testing and Commissioning of 10W LED Bulkhead fitting with aluminium diecast housing with powder coating, Polycarbonate opal diffuser, Dome with silicon gasket for IP65 Protection, Complete assembly with LED, Driver and accessories pre wired up to terminal block. CRI80,CCT-5700K

140.7

-

-

... More
Supply & Installation, Testing and Commissioning of 80W High efficient LED with aluminium die-cast housing luminaire with unique lens system for enhanced uniform illumination and toughened glass with silicon gasket for IP66 protection.CRI70, IP66, Ambient temp-0 to 45DegC, Driver efficiency87%, THD10%, Powerfactor0.95, Surge protection-3 kV, Multistage Isolated Constant Current-Constant Voltage operated driver with range 150-270V AC and Safety Extra Low Voltage Safe level60V DC as per IEC standard. Colour Temperature - 5700k. Luminaire lumen ≥ 6800 lm.

6.3

-

-

... More
Supply & Installation, Testing and Commissioning of 22W 4ft,width-51mm, High efficiency long life Linear suspended luminaire with white powder coated finish extruded aluminium housing. UGR19. LED driver duly wired up to terminal block for easy installation and long service. Luminous efficacy not less than 110lm/W. CRI80, IP20, Ambient temp-0 to 45DegC, Driver efficiency85%, THD10%, CCT- 5700K, 50,000 hrs @ L70 life, Powerfactor0.95, Surge protection-2 kV, Multistage Isolated Constant Current-Constant Voltage operated driver with range 150-270V AC and Safety Extra Low Voltage Safe level60V DC as per IEC standard.Luminaire lumen ≥ 2200lm

63

-

-

... More
Supply & Installation, Testing and Commissioning of Parking Area Sensor - Mid Range LightSpot is a high-performance, directional presence detector with built-in photocell for use in almost any internal space. With a range of up to 20m by 20m

5

-

-

... More
Supply & Installation, Testing and Commissioning of 30W, 2X2 Clean Room fixture,100Lms/W, Housing made of CRCA & frame in aluminum duly powder coated in white (RAL9016), Slimmest and sleek profile with No visible hardware on external surface, High Efficiency Translucence (HET) diffuser, CCT-5700K, IP20.

2

-

-

... More
Supply & Installation, Testing and Commissioning of 30W IP65 rated pole mounted Aviation Light fixture in the terrace with all mounting accessories

4

-

-

... More
Supply and installation of Architectural LED Light fixture (60W-70W) (Side Mounting), Power Module LED, 4000K,IP 66, 6000lm minimum, Body in circular shape made of die-cast aluminum using pressure die casting process. manufacturer name/logo should be embosed on the body. Prismatic/Frosted screen in Flat tempered glass. Pure polyester powder coating in customised colour Metallaic Grey. Silicone gasket ensures the IP Rating - IP 66. Height – 70mm,Diameter - 420mm,Weight -8Kgs. Power LED Module with Company/brand name printed on PCB with the metal core plate, in compliance with IEC 62031 (Supporting Test Report from UL/UL Authorised/Intertek Laboratory should be submitted). CRI 70. LED Chips of CREE/NICHIA/OSRAM/LUMILEDS make shall be used- same should be supported by LED manufacturer's tech sheet . Electronic Power Supply for LED Module, which offers Protection against Short Circuit, Over- Voltage & Over- Current, with in-built surge protection (an additional surge protection device of 10kV also provided in-built the fixture). Optics with refractive lens in PMMA which should offer all the Type II,III,IV & V distribtuions. LED Lifetime 1,00,000hours@Ts 85°C. LM80 report from LED Manufacturer should be submitted. Safety test report as per IEC 60598 from UL/UL Authorised/Intertek lab should be submitted. LM79 report also should be submitted fromUL/UL Authorised/Intertek Laboratory. Sample should be submitted for approval from concerned engineer-in charge.

26

-

-

... More
Supply and installation of high quality integrated LED post top Luminaire with a system lumen of 4500Lm and system wattage between 60W-70W with an efficiency 100lumen/watt. CCT of 5700K with SDCM of 5 and CRI 70. The housing should be high quality pressure die cast aluminum LM6 Alloy with PF 0.95 & Surge Protection of 4KV Internal & 10 kV External. Input voltage of 140-270V. Operating temperature should be -0 to +50 Deg C. Lifetime of 50K hours @L70. Product should be suitable for continuous operation (8 Hrs. per day). The Ingress protection should be minimum IP 65 with an IK rating of 05. The luminaire should have Integrated optics to provide a high quality glare free lighting system. The luminaire should be of Class B Serviceability, Driver Voltage range 140-270V AC and Safety Extra Low Voltage Safe level60V DC as per IEC standard, high voltage cutoff & auto restart @320V, phase to phase 440V protection upto 8hrs. The luminaire should be compliant to CISPR 15 & IES 61547 (EMC, EMI compliant). The Driver should be potted /encapsulated & should be a BIS approved driver and not a printed circuit board without casing, mounted inside the luminaire. . BIS approval for Both Driver and the luminaire needs to be submitted for records. The Light fixture body colour needs to be customised as per the Mounting pole colour.

5

-

-

... More
Supply & Installation of architectural pole - 6-7M Height Pole made in combination MS Pipe of 89mm dia & top single arm bracket which is made of hot dip galvanised mild steel pipe sections 60mm dian with pleasing aesthetics. The pole to be provided with a suitable size steel base plate. This mounting steel base plate along with foundation bolts of suitable size to be used for ensuring firm grouting into the specially designed RCC foundation. Entire pole & bracket shall be made to provide pleasing aesthetics as approved by Concerned Engineer in-charge. After Fabrication, Entire Pole is hot dip galvanized(60 microns Minimum ) for the effective corrosion resistance . The hot dip Galvanised pole should be provided with an inbuilt junction box to fix 32A connectors and 6A MCB, at the bottom - the inbuilt box should have a flush door of suitable size. wind pressure calculation as per IS 875(part-3) & structural calculation report as per EN40 should be submitted to verify the pole strength. Pole & it's partsare painted in 3 layer coating(coating thickness-100 microns minimum) in which 1st layer with etch primer, 2nd layer with epoxy primer & 3rd final layer with PU paint- Grey colour

47

-

-

... More
Supply and Installation of Architectural Lighting Bollard - (10W-15W) LED - Module, 3000K, IP65 - The Lighting Bollard suitable for on ground installation is made of extruded aluminium, die cast aluminium and hot galvanized steel . It's screen made of acrylic with high impact resistance,in single piece. Pure polyester powder coating in Standard Grey Colour. IP Rating - IP 65. Height – 1000mm, Dia - 127mm LED Module on Printed Circuit Board with metal core plate.Colour Rendering Index: Ra 70.Electronic Power Supply for LED Module, which offers Protection against Short Circuit, Over- Voltage & Over- Current. Estimated LED Lifetime L80 @50,000 hours minimum. Sample should be submitted for approval from concerned engineer-in charge.

101

-

-

... More
SUPPLY & INSTALLATION OF INTERIOR LIGHTING

-

-

-

... More
Supply & Installation, Testing and Commissioning of 18W, High efficient recess mounted LED round downlighter with white powder coated, pressure die cast aluminium housing. High transmittivity PS diffuser provides soft light. CRI80, IP20, Ambient temp-0 to 45DegC, CCT - 4000K, 50,000 hrs @ L70 life.Driver efficiency85%, THD10%, Powerfactor0.9, Surge protection-2 kV, Multistage Isolated Constant Current-Constant Voltage operated driver with range 90-265V AC and Safety Extra Low Voltage Safe level60V DC as per IEC standard.IP40(Housing),IP20(Driver). Luminaire lumen ≥ 1800 lm. (100 lm/W) - Cutout Dia-ø145mm.

45

-

-

... More
Supply & Installation, Testing and Commissioning of 15W, High efficient recess mounted LED round downlighter with white powder coated, pressure die cast aluminium housing. High transmittivity PS diffuser provides soft light. CRI80, IP20, Ambient temp-0 to 45DegC, CCT - 4000K, 50,000 hrs @ L70 life. Driver efficiency85%, THD10%, Powerfactor0.9, Surge protection-2 kV, Multistage Isolated Constant Current-Constant Voltage operated driver with range 90-265V AC and Safety Extra Low Voltage Safe level60V DC as per IEC standard.IP40(Housing),IP20(Driver). Luminaire lumen ≥ 1500 lm. (100 lm/W) - Cutout Dia-ø145mm.

55

-

-

... More
Supply & Installation, Testing and Commissioning of 15W, High efficient recess mounted LED round downlighter with white powder coated, pressure die cast aluminium housing. High transmittivity PS diffuser provides soft light. CRI80, IP20, Ambient temp-0 to 45DegC, CCT - 4000K, 50,000 hrs @ L70 life. Driver efficiency85%, THD10%, Powerfactor0.9, Surge protection-2 kV, Dali Dimmable driver with range 90-265V AC and Safety Extra Low Voltage Safe level60V DC as per IEC standard.IP40(Housing),IP20(Driver). Luminaire lumen ≥ 1500 lm. (100 lm/W) - Cutout Dia-ø145mm.

15

-

-

... More
Supply & Installation, Testing and Commissioning of 20W 4ft,width-51mm, High efficiency long life Linear suspended luminaire with white powder coated finish extruded aluminium housing. UGR19. LED driver duly wired up to terminal block for easy installation and long service. Luminous efficacy not less than 110lm/W. CRI80, IP20, Ambient temp-0 to 45DegC, Driver efficiency85%, THD10%, CCT- 5700K, 50,000 hrs @ L70 life, Powerfactor0.95, Surge protection-2 kV, Multistage Isolated Constant Current-Constant Voltage operated driver with range 150-270V AC and Safety Extra Low Voltage Safe level60V DC as per IEC standard.Luminaire lumen ≥ 2200lm.

25

-

-

... More
Supply & Installation, Testing and Commissioning of 40W 8ft,width-51mm, High efficiency long life Linear suspended luminaire with white powder coated finish extruded aluminium housing. UGR19. LED driver duly wired up to terminal block for easy installation and long service. Luminous efficacy not less than 110lm/W. CRI80, IP20, Ambient temp-0 to 45DegC, Driver efficiency85%, THD10%, CCT- 5700K, 50,000 hrs @ L70 life, Powerfactor0.95, Surge protection-2 kV, Multistage Isolated Constant Current-Constant Voltage operated driver with range 150-270V AC and Safety Extra Low Voltage Safe level60V DC as per IEC standard.Luminaire lumen ≥ 4400lm.

5

-

-

... More
Supply & Installation, Testing and Commissioning of 20W, 80mm diameter, 175mm hieght, LED pendent mounted Cylindrical Down Light with 80lm/W ±10% system efficacy. Luminaire shall be made up of Die Cast powder coated housing. Luminaire shall have Optical Grade shall be provided with clear glass lens with high efficiency & minimum glare to maintain 60 deg beam angle (24 deg beams are also available on request). LM 80-08 compliant, ANSI rated LEDs from reputed makes such as Nichia, Japan / Cree, USA / Bridge lux, USA / Lumiled USA / Citizen Japan should be provided. LEDs must be driven at 70% of maximum rated current for higher reliability in all our products. The LED shall be compliant with LM80-08 standard with Useful L70 life of 50000 Hrs. (Complete LM 80 test report for LED should be submitted). The LEDs used in luminaire should from Mac Adams Step 5 for CCT binning with CCT of 5700K and CRI of Minimum 80.

10

-

-

... More
Supply & Installation, Testing and Commissioning of 30W, 2X2 fixture,100Lms/W, UGR19, Housing made of CRCA & frame in aluminum duly powder coated in white (RAL9016), Slimmest and sleek profile with No visible hardware on external surface, High Efficiency Translucence (HET) diffuser,CCT-5700K, IP20.

66

-

-

... More
Supply & Installation, Testing and Commissioning of 20W 4ft,width-51mm, High efficiency long life Linear Recess mounted luminaire with white powder coated finish extruded aluminium housing. UGR19. LED driver duly wired up to terminal block for easy installation and long service. Luminous efficacy not less than 110lm/W. CRI80, IP20, Ambient temp-0 to 45DegC, Driver efficiency85%, THD10%, CCT- 5700K, 50,000 hrs @ L70 life, Powerfactor0.95, Surge protection-2 kV, Multistage Isolated Constant Current-Constant Voltage operated driver with range 150-270V AC and Safety Extra Low Voltage Safe level60V DC as per IEC standard.Luminaire lumen ≥ 2200lm.

5

-

-

... More
Supply & Installation, Testing and Commissioning of 40W 8ft,width-51mm, High efficiency long life Linear Recess mounted luminaire with white powder coated finish extruded aluminium housing. UGR19. LED driver duly wired up to terminal block for easy installation and long service. Luminous efficacy not less than 110lm/W. CRI80, IP20, Ambient temp-0 to 45DegC, Driver efficiency85%, THD10%, CCT- 5700K, 50,000 hrs @ L70 life, Powerfactor0.95, Surge protection-2 kV, Multistage Isolated Constant Current-Constant Voltage operated driver with range 150-270V AC and Safety Extra Low Voltage Safe level60V DC as per IEC standard.Luminaire lumen ≥ 4400lm.

2

-

-

... More
Digital PIR Regulating presence detection sensor of range Micro Detection - High Sensitivity Range 10 m Dia at height of 2.5 meter ( 7 m dia Micro Sensitivity 3 m macro) to control 10A lighting load. Capable of dimming 15 dimmable DSI/ DALI ballast. To be commissioned by hand held programmer with programmable features of delay time 10sec-96 hrs, photocell and power up (status of luminaires when power is applied). It shall have provision to manually override the luminaires’ ON / OFF / regulate lighting level status using hand held remote control and wired input for One switch control (push switch) to ON / OFF / regulate the lighting level. (PHILIPS / SCHEIDER / HAVELLS)

112

-

-

... More
DECORATIVE LIGHT FIXTURE TYPE -1 Supply & Installation, Testing and Commissioning of Pendant /Suspended Circular luminaire with system power 9- 15W LED , luminous flux of luminaire 1400 lm, Indirect light emission CRI 80, colour temperature of 4000 K, Neutral white, 230 V constant current driver, 70% of luminous flux after 50,000 operating hours, energy-efficient LEDs, luminaire profile in aluminium, Polyester powder Black colored coat applied over a 5- stage pre-treatment, indirect Opal diffuser , ZHLS (Zero Halogen Low Smoke) internal wiring, DALI control gear, Protection class I, IP 20, Ø = 300 mm, H = 150 mm.

20

-

-

... More
DECORATIVE LIGHT FIXTURE TYPE -2 Supply & Installation, Testing and Commissioning of Decorative pendant luminaire with HPE (High Performance Efficiency) LED luminaire lumens not less than 26 W, luminous flux of luminaire 2730 lm with system efficacy of 105 lm/W, Colour temperature of 6500 K, Cool white, CRI 80, 230V constant current driver, 70% of luminous flux after 50,000 operating hours; Energy efficient LEDs, MacAdam 3, Direct light emission, Luminaire housing in aluminium, Polyester powder black or white coloured coat applied over a 5- stage pre-treatment, Opal diffuser for a homogenous light distribution ZHLS (Zero Halogen Low Smoke) internal wiring, Electronic control gear, Protection class I, IP 20, The luminaire Dimesion shall be not less than Ø = 427 mm, H = 227 mm.

42

-

-

... More
DECORATIVE LIGHT FIXTURE TYPE -3 Supply & Installation, Testing and Commissioning of Ceiling Mounted Circuar Decorative light with HPE (High-Performance Efficiency) LED (Light Emitting Diode) system power: 35 W luminous flux of luminaire 3500 lm, Colour temperature of 5700K, cool white CRI 80, 230V constant current driver, 70% of luminous flux after 50,000 operating hours; Energy efficient LEDs, Direct light emission, luminaire housing in aluminium, Polyester powder white coloured coat applied over a 5- stage pre-treatment, pre-wired backplate luminaire, Prismatic diffuser for homogenous light distribution, ZHLS (ZERO HALOGEN LOW SMOKE) internal wiring, DALI control gear, Protection class I, IP20, Ø = 530 mm, H = 110 mm.

12

-

-

... More
DECORATIVE CHANDELIER LIGHT FIXTURE TYPE -4 Supply & Installation, Testing and Commissioning of Square Gold plate and Crystal Flush Mount Ceiling Chandelier. Light source - LED Material: Prefabricated , stainless steel base, Clear crystal pendant Voltage: 220V Installation Type: Flush Mount Switch Type: On/Off Size: 1800mm(L) x 900mm(W) Note: This item shall be got prior approval from client/Architect before fabrication.

5

-

-

... More
DECORATIVE CHANDELIER LIGHT FIXTURE TYPE -5 Supply & Installation, Testing and Commissioning of Square Gold plate and Crystal Flush Mount Ceiling Chandelier. Light source - LED Material: Prefabricated , stainless steel base, Clear crystal pendantt Voltage: 220V Installation Type: Flush Mount Switch Type: On/Off Size: 23M(L) X 1.5M(W) Note: This item shall be got prior approval from client/Architect before fabrication.

2

-

-

... More
DECORATIVE CHANDELIER LIGHT FIXTURE TYPE - 6 Supply & Installation, Testing and Commissioning of Square Gold plate and Crystal Flush Mount Ceiling Chandelier. Light source - LED Material: Prefabricated , stainless steel base, Clear crystal pendantnt Voltage: 220V Installation Type: Flush Mount Switch Type: On/Off Size: 600mm(L) x 600mm(W) Note: This item shall be got prior approval from client/Architect before fabrication.

6

-

-

... More
DECORATIVE CHANDELIER LIGHT FIXTURE TYPE - 7 Supply & Installation, Testing and Commissioning of Square Gold plate and Crystal Flush Mount Ceiling Chandelier. Light source - LED Material: Prefabricated , stainless steel base, Clear crystal pendant Voltage: 220V Installation Type: Flush Mount Switch Type: On/Off Size: 1300mm(L) x 900mm(W) Note: This item shall be got prior approval from client/Architect before fabrication.

5

-

-

... More
DECORATIVE HEXAGONAL SUSPENDED LIGHT FIXTURE TYPE - 8 Supply & Installation, Testing and Commissioning of Suspended continous mounted LED luminaire with wattage of 22W in Hexageon Shape as per false ceiling arrangements . The luminaire shall deliver lumen not less than 2420 lm with system efficacy of 110 lm/W. The Single luminaire dimension shall be not less than 50x85x1120mm (approx). Luminaire Consists of Grey powder coated finish pressure diecast aluminium housing & Special translucent satin finish colour LED PMMA diffuser for only downward distribution. LED make: that satisfies IEC62471 Photobiological/RoHS Standards with and LED Efficacy of 150lm/W, Colour Temperature-6500K or Higher with LED binning as per ANSI Bin C78.377A, 120Deg LED Beam Angle, CRI 80, Life of LED as per L70 50000burning hours, Ambient temp-0 to 50DegC, Driver efficiency85%, THD10%, Power factor0.95, Inbuilt Surge protection in CM ≥ 3.0KV, LED Driver with Voltage range 150-270V AC and Safety Extra Low Voltage Safe level60V DC as per IEC standard, Electrical Safety with Class 1 Insulation

2

-

-

... More
WIRING FOR LUMINAIRES CIRCUIT MAIN (FROM DB TO FIRST POINT) Supply, Laying, Testing and Commissioning of Wiring for Circuit/submains along with earth wire with 2R 2.5Sq.mm + 1R 2.5S.mm FRLS PVC insulated multistrand copper wire in surface /recessed MS conduit with all accessories as required as per site conditions. For concealed conduiting, wall chasing and finishing need to be considered in the quote. Conduit colour to be black in all closed ceiling and white in all open ceiling or as directed by PMC/Employer. Wire`s colour coding should be as per PMC/Employer in charge..

14036

-

-

... More
Supply, Laying, Testing and Commissioning of Wiring for Circuit/submains along with earth wire with 2R 2.5Sq.mm + 1R 2.5S.mm FRLS PVC insulated multistrand copper wire in surface /recessed medium class PVC conduit with all accessories as required as per site conditions. For concealed conduiting, wall chasing and finishing need to be considered in the quote. Wire`s colour coding should be as per PMC/Employer in charge.

-

-

-

... More
Supply, Laying, Testing and Commissioning of Wiring for submains along with earth wire with 2R 1.5Sq.mm + 1R 1.5S.mm FRLS PVC insulated multistrand copper wire in surface /recessed MS conduit with all accessories as required as per site conditions. For concealed conduiting, wall chasing and finishing need to be considered in the quote. Conduit colour to be black in all closed ceiling and white in all open ceiling or as directed by PMC/Employer. Wire`s colour coding should be as per PMC/Employer in charge.

-

-

-

... More
POINT WIRING - SWITCH CONTROL Supply, installation, Testing and Commissioning of point wiring using 2R x 2.5Sq.mm + 1Rx 1.5Sq.mm for Primary & 3R x 1.5 for Secondary wiring FRLS 1100V wire of approved make drawn in 20mm dia GI conduit including all conduit accessories such as bends, junction boxes etc., complete. The wiring shall be complete with ceiling roses, switches and all consumables. The wiring shall be complete with ceiling roses, switches and all consumables. The rate shall include providing mounting boxes with tapped holes for lights switches, moulded front plates with brass screws earthing of all points using third wire Conduit colour to be black in all closed ceiling and white in all open ceiling Point wiring for lights to be with connectors & flexible drops to be with proper sockets Any conduits crossing partitions/walls should have appropriate sleeves with fire sealant (fire sealant shall be in civll vendor scope) For concealed conduiting, wall chasing and finishing need to be considered in the quote.

-

-

-

... More
PRIMARY LIGHT POINT Supply, installation, Testing and Commissioning of point wiring using 2Rx2.5Sq.mm + 1Rx1.5Sq.mm FRLS 1100V wire of approved with 20 mm dia GI conduit including all accessories such as bends, junction boxes etc., complete. The wiring shall be complete with ceiling roses. The rate shall include providing mounting boxes with tapped holes for lights switches, moulded front plates with brass screws earthing of all points using third wire I. Primary light point means wiring from first switch control to the first light outlet. The switch and all necessary accessories would be part of primary point. II. Not to include the incoming lighting circuit from MCB-DB to switch. III. 3 core PVC transparent clear electrical cable flex wire/cable shall be included at the drop of light fixture, flexibles with connectors and adaptors

465.3

-

-

... More
SECONDARY LIGHT POINT I. Secondary light point means extension of light outlet from existing primary point with 20mm dia GI conduit with 3RX1.5 Sqmm FRLS 1100V wire. Same to be controlled by the existing switch of primary point. II. 3 core PVC transparent clear electrical cable flex wire/cable shall be included at the drop of light fixture.

1361.8

-

-

... More
POINT WIRING - SENSOR + SWITCH CONTROL Supply, installation, Testing and Commissioning of point wiring using 2R x 2.5Sq.mm + 1Rx 1.5Sq.mm for Primary & 3R x 1.5 for Secondary wiring FRLS 1100V wire of approved make drawn in 20mm dia MS conduit including all conduit accessories such as bends, junction boxes etc., complete. The wiring shall be complete with ceiling roses, switches and all consumables. The wiring shall be complete with ceiling roses, switches and all consumables. The rate shall include providing mounting boxes with tapped holes for lights switches, moulded front plates with brass screws earthing of all points using third wire Conduit colour to be black in all closed ceiling and white in all open ceiling Point wiring for lights to be with connectors & flexible drops to be with proper sockets Any conduits crossing partitions/walls should have appropriate sleeves with fire sealant (fire sealant shall be in civll vendor scope) For concealed conduiting, wall chasing and finishing need to be considered in the quote.

-

-

-

... More
PRIMARY LIGHT POINT Supply, installation, Testing and Commissioning of point wiring using 2Rx2.5Sq.mm + 1Rx1.5Sq.mm FRLS 1100V wire of approved with 20 mm dia MS conduit including all accessories such as bends, junction boxes etc., complete. The wiring shall be complete with ceiling roses. The rate shall include providing mounting boxes with tapped holes for lights switches, moulded front plates with brass screws earthing of all points using third wire I. Primary light point means wiring from first switch control to the sensor, the first light outlet and to the subsequent next Switch/sensor in that circuit. The switch and all necessary accessories would be part of primary point. II. Not to include the incoming lighting circuit from MCB-DB to switch. III. 3 core PVC transparent clear electrical cable flex wire/cable shall be included at the drop of light fixture, flexibles with connectors and adaptors

96

-

-

... More
SECONDARY LIGHT POINT I. Secondary light point means extension of light outlet from existing primary point with 20mm dia GI conduit with 3RX1.5 Sqmm FRLS 1100V wire. Same to be controlled by the existing switch/Sensor of primary point. II. 3 core PVC transparent clear electrical cable flex wire/cable shall be included at the drop of light fixture.

192

-

-

... More
POINT WIRING - MCB CONTROL Supply, installation, Testing and Commissioning of point wiring using 3R x 1.5Sq.mm for Secondary wiring FRLS 1100V wire of approved make drawn in 20mm dia MS conduit including all conduit accessories such as bends, junction boxes, cieling rose etc., complete. The wiring shall be complete with ceiling roses and all consumables. DB to first light is measured under the circuit main.

-

-

-

... More
SECONDARY LIGHT POINT I. Secondary light point means extension of light outlet from existing primary point with ceiling rose & complete accessories. Same to be controlled by the existing MCB in DB II. 3 core PVC transparent clear electrical cable flex wire/cable shall be included at the drop of light fixture for power wiring

352

-

-

... More
Elevator Shaft Lighting (GF+1F+2F+3F+4F+5F+6FTF) - 8 Floors Consider surface mounted conduiting. comprising of : - a. 12w LED Bulk Head - IP65 Protection b. 6A 3 Pin switched socket outlet c. Wiring for light points controlled by a 6A switch. d. Wiring for pit Power Points using 2 Nos 6A 2 switches. e. Wiring for sets of 6A switch with Light point and 6A switched & socket outlets. consist of followings wire for power circuit : 3 runs of 4.0 sq.mm 6 Module Open Box, 6 Module Front plate and 2 Nos Switches and 2 Nos 6A socket Conduit: 20mm MS Conduit for lighting & 25 mm dia MS Conduit for Power.

14

-

-

... More
WIRING FOR POWER MAIN POWER WIRING

-

-

-

... More
Supply, Laying, Testing and Commisiosning of 2R 6Sqmm + 1R 6 Sq..mm PVC insulated FRLS multistrand copper wire in GI conduit with all accessories as required as per site conditions. For concealed conduiting, wall chasing and finishing need to be considered in the quote.

2040

-

-

... More
Supply, Laying, Testing and Commisiosning of 2R 4Sqmm + 1R 4Sq.mm PVC insulated FRLS multistrand copper wire in GI conduit with all accessories as required as per site conditions. For concealed conduiting, wall chasing and finishing need to be considered in the quote.

14085.5

-

-

... More
Supply, Laying, Testing and Commisiosning of 2R 2.5Sqmm + 1R 2.5Sq.mm PVC insulated FRLS multistrand copper wire in GI conduit with all accessories as required as per site conditions. For concealed conduiting, wall chasing and finishing need to be considered in the quote.

100

-

-

... More
POWER OUTLETS (SOCKETS) Supply, Installation, testing and commissioning of the following Modular / Industrial Switch, sockets with modular front plate and accessories as per the technical specification & drawing details. The quoted rate shall be inclusive of approved make modular switches, accessories, 14SWG back box & shall be covered with removable film coat to protect from scratches and paint.

-

-

-

... More
Supply and fixing of 1 no.6/16A two module 5 pin socket , 1 no. 16A one module switch with module cover plate (plastic) on suitable module concealed Box (GI ) in flush with wall with connections. Higher End

191

-

-

... More
Supply and fixing of 1 no.10A two module 5 pin socket , 1 no. 10A one module switch with module cover plate (plastic) on suitable module concealed Box (GI ) in flush with wall with connections. Higher End

11

-

-

... More
Supply and fixing of 1 no.6/16A two module 5 pin socket , 1 no. 16A one module switch with module cover plate (plastic) on suitable module concealed Box (GI ) in flush with wall with connections. Higher End - Weather Proof (With Back box) - IP66

16

-

-

... More
Supply and fixing of 1 no.6A two module 5 pin socket , 1 no. 6A one module switch with module cover plate (plastic) on suitable module concealed Box (GI ) in flush with wall with connections. Higher End (Without Back box)

80

-

-

... More
Supply and fixing of 2 no.6A two module 5 pin socket , 1 no. 16A one module switch with module cover plate (plastic) on suitable module concealed Box (GI ) in flush with wall with connections. Higher End (Without Back box)

25

-

-

... More
Supply and fixing of 3 no.6A two module 5 pin socket , 1 no. 16A one module switch with module cover plate (plastic) on suitable module concealed Box (GI ) in flush with wall with connections. Higher End (Without Back box)

63

-

-

... More
Supply and fixing of 1 no.6A two module 5 pin socket , 1 no. 6A one module switch with module cover plate (plastic) on suitable module concealed Box (GI ) in flush with wall with connections. Higher End (With Back box)

45

-

-

... More
Supply and fixing of 2 no.6A two module 5 pin socket , 1 no. 16A one module switch with module cover plate (plastic) on suitable module concealed Box (GI ) in flush with wall with connections. Higher End (With Back box)

10

-

-

... More
Supply and fixing of 3 no.6A two module 5 pin socket , 1 no. 16A one module switch with module cover plate (plastic) on suitable module concealed Box (GI ) in flush with wall with connections. Higher End (With Back box)

10

-

-

... More
Supply and installation of 1No. Of 16A 3 pin single phase Industrial type socket with plug top controlled by 16A DP MCB

11

-

-

... More
Supply and installation of 1No. Of 16A 5 pin single phase Industrial type socket with plug top controlled by 16A 4P MCB

6

-

-

... More
Supply and installation of 1No. Of 32A 3 pin single phase Industrial type socket with plug top controlled by 32A DP MCB

5

-

-

... More
Supply and installation of 16A Single pole switch for Tenant area Lighting

41

-

-

... More
Supply, Fixing, Testing and Commissioning of 32A DP MCB enclosed in weather proof MS Enclosure with and other associated accessories as required as per the site conditions (Master Control MCB)

1

-

-

... More
Supply and installation of 20A 3 Pin 1 phase industrial socket controlled by 20A DP MCB for car charging

16

-

-

... More
Supply and installation of 1No. Of 6A socket controlled by 6A SP switch (With Back box)

103.6

-

-

... More
Supply, Fixing, Testing and Commissioning of 3.7kW AC Single phase EV charger with plug top with 5Mtr length cable & all accessories. in weather proof MS Enclosure with angle Iron Frame and other associated accessories as required as per the site conditions

40

-

-

... More
Supply, Fixing, Testing and Commissioning of 11kW AC Three phase EV charger with plug top with 5Mtr Length & all accessories. in weather proof MS Enclosure with angle Iron Frame and other associated accessories as required as per the site conditions

31

-

-

... More
CABLE TRAY Supply, fabrication, installation & painting of Hot Dip galvanized (65 - 70 Micron as per IS2629) Ladder cable racks / trays of up to 300 ( 1.6mm thickness ) & more than 300mm up to 750mm (2 mm thickness) more than or equal to 1000mm ( 2.5 thickness) with necessary painted G.I structural supports in horizontal or vertical formation & single / multitier formation as specified and shown on drawings. Up to 450mm - cable trays shall be supplied along with rod and C channel, refer specifications. Above 450mm cable tray support shall be with suitable angle supports as per specifications. The rate shall include GI supports, bends, Tees, all supporting brackets, anchor fasteners, screws, bolts, nuts etc. The Proper Floor supports need to be considered for the terrace floor cable tray as per the drawing. Supply, fabrication, installation & painting of Hot Dip galvanized (65 - 70 Micron as per IS2629) Ladder cable racks / trays of up to 300 ( 1.6mm thickness ) & more than 300mm up to 750mm (2 mm thickness) more than or equal to 1000mm ( 2.5 thickness) with necessary painted G.I structural supports in horizontal or vertical formation & single / multitier formation as specified and shown on drawings.

-

-

-

... More
Supply, fabrication, installation & painting of Hot Dip galvanized (65 - 70 Micron as per IS2629) Ladder cable racks / trays - 100X50mm Cable Tray

10

-

-

... More
Supply, fabrication, installation & painting of Hot Dip galvanized (65 - 70 Micron as per IS2629) Ladder cable racks / trays - 150X50mm Cable Tray

1753.5

-

-

... More
Supply, fabrication, installation & painting of Hot Dip galvanized (65 - 70 Micron as per IS2629) Ladder cable racks / trays - 200X50mm Cable Tray

10

-

-

... More
Supply, fabrication, installation & painting of Hot Dip galvanized (65 - 70 Micron as per IS2629) Ladder cable racks / trays - 300X50mm Cable Tray

10

-

-

... More
Supply, fabrication, installation & painting of Hot Dip galvanized (65 - 70 Micron as per IS2629) Ladder cable racks / trays - 450X50mm Cable Tray

360.15

-

-

... More
Supply, fabrication, installation & painting of Hot Dip galvanized (65 - 70 Micron as per IS2629) Ladder cable racks / trays - 600X75mm Cable Tray

105

-

-

... More
Supply, fabrication, installation & painting of Hot Dip galvanized (65 - 70 Micron as per IS2629) Ladder cable racks / trays - 750X75mm Cable Tray

504

-

-

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness 65 - 70 Micron as per IS2629) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. as specified and shown on drawings. Up to 450mm - cable trays shall be supplied along with rod and C channel, refer specifications. Above 450mm cable tray support shall be with suitable angle supports as per specifications.

-

-

-

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness 65 - 70 Micron as per IS2629) - 100 mm width X 50 mm depth X 1.6 mm thickness

15

-

-

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness 65 - 70 Micron as per IS2629) - 150 mm width X 50 mm depth X 1.6 mm thickness

10

-

-

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness 65 - 70 Micron as per IS2629) - 225mm width X 50 mm depth X 1.6 mm thickness

18

-

-

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness 65 - 70 Micron as per IS2629) - 300 mm width X 50 mm depth X 1.6 mm thickness

19

-

-

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness 65 - 70 Micron as per IS2629) - 450 mm width X 62.5 mm depth X 2.0 mm thickness

15

-

-

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "bends" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.

-

-

-

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "bends" (galvanisation not less than 50 microns) - 100 mm width X 50 mm depth X 1.6 mm thickness

1

-

-

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "bends" (galvanisation not less than 50 microns) - 150 mm width X 50 mm depth X 1.6 mm thickness

1

-

-

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "bends" (galvanisation not less than 50 microns) - 225mm width X 50 mm depth X 1.6 mm thickness

1

-

-

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "bends" (galvanisation not less than 50 microns) - 300 mm width X 50 mm depth X 1.6 mm thickness

1

-

-

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "bends" (galvanisation not less than 50 microns) - 450 mm width X 62.5 mm depth X 2.0 mm thickness

1

-

-

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Tee" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.

-

-

-

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Tee" (galvanisation not less than 50 microns) - 225mm width X 50 mm depth X 1.6 mm thickness

1

-

-

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Tee" (galvanisation not less than 50 microns) - 300 mm width X 50 mm depth X 1.6 mm thickness

1

-

-

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Tee" (galvanisation not less than 50 microns) - 450 mm width X 62.5 mm depth X 2.0 mm thickness

1

-

-

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Cross member"(galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.

-

-

-

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Cross member"(galvanisation not less than 50 microns) 100 mm width X 50 mm depth X 1.6 mm thickness

20

-

-

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Cross member"(galvanisation not less than 50 microns) 150 mm width X 50 mm depth X 1.6 mm thickness

39

-

-

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Cross member"(galvanisation not less than 50 microns) 225mm width X 50 mm depth X 1.6 mm thickness

13

-

-

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Cross member"(galvanisation not less than 50 microns) 300 mm width X 50 mm depth X 1.6 mm thickness

12

-

-

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Cross member"(galvanisation not less than 50 microns) 450 mm width X 62.5 mm depth X 2.0 mm thickness

20

-

-

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Reducer"(galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.

-

-

-

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Reducer" (galvanisation not less than 50 microns) - 100 mm width X 50 mm depth X 1.6 mm thickness

20

-

-

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Reducer" (galvanisation not less than 50 microns) - 150 mm width X 50 mm depth X 1.6 mm thickness

39

-

-

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Reducer" (galvanisation not less than 50 microns) - 225mm width X 50 mm depth X 1.6 mm thickness

13

-

-

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Reducer" (galvanisation not less than 50 microns) - 300 mm width X 50 mm depth X 1.6 mm thickness

12

-

-

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Reducer" (galvanisation not less than 50 microns) - 450 mm width X 62.5 mm depth X 2.0 mm thickness

20

-

-

... More
RACEWAY - FLOOR Supply & Installation of following size Pregalvanized - GI raceway / wire way with cover, made out of 16 SWG for body and 14 SWG for cover. Junction boxes to be provided with enough supports inside the box. Raceway installed above false ceiling/floor shall include necessary mounting supports, junction boxes and accessories to fix it firmly to the ground/ ceiling. The raceways shall be fixed to the floor with GI/MS (25mm x 3mm) strips so that there is no movement of the channels when civil work (pouring of cement concrete) is being done. Rate includes necessary floor cutting and chipping with machine of minimum 50mm depth, removal of debris out of site and neatly finished with M15 grade concrete up to the finished floor level. Race ways to be covered with Chicken mesh before concreting. Curing compound to be applied after initial setting of the concrete. All edges, cut faces shall be free of burrs & shall be smooth. The channels shall be earthed at the boxes and at the joints with 14 SWG bare copper wire with screws so that earth is continuous. Jointing of the race ways to be done with welding.

-

-

-

... More
Junction boxes - Floor

-

-

-

... More
Supply & Installation of floor Junction box - 90 x 90 x 50mm Size

13

-

-

... More
Supply & Installation of floor Junction box - 110 x 110 x 50mm Size

60

-

-

... More
Supply & Installation of floor Junction box - 160 x 160 x 50mm Size

5

-

-

... More
Supply & Installation of floor Junction box - 210 x 210 x 50mm Size

10

-

-

... More
Supply & Installation of floor Junction box - 260 x 260 x 50mm Size

5

-

-

... More
Supply & Installation of floor Junction box - 310 x 310 x 50mm Size

5

-

-

... More
Supply & Installation of floor Junction box - 410 x 410 x 50mm Size

5

-

-

... More
Floor Raceways : 'Supply & Installation of following size Pre galvanised raceway with above specified worksgiven in item no.28

-

-

-

... More
Supply & Installation of following size Pre galvanised raceway - 50 x 38mm Size

15

-

-

... More
Supply & Installation of following size Pre galvanised raceway - 100 x 38mm Size

120

-

-

... More
Supply & Installation of following size Pre galvanised raceway - 150 x 38mm Size

10

-

-

... More
Supply & Installation of following size Pre galvanised raceway - 200 x 38mm Size

10

-

-

... More
Supply & Installation of following size Pre galvanised raceway - 250 x 38mm Size

10

-

-

... More
Supply & Installation of following size Pre galvanised raceway - 300 x 38mm Size

10

-

-

... More
Supply & Installation of following size Pre galvanised raceway - 400 x 38mm Size

10

-

-

... More
Supply and Installation of Powdered coated box trays made of 2m thick GI sheet and top removable cover with 2mm thick sheet as required. The rate shall include the joint pieces which made of 2mm thick GI sheet as required. The distribution raceways only shall be provided with 25/32/40mm knockouts wherever required. also the cost shall inclusive of necessary fixing accessories. (powdered coated colour shall be approved by architect).

-

-

-

... More
Supply and Installation of Powdered coated box trays made of 2m thick GI sheet and top removable cover for - 150 x 75 x 2 mm

10

-

-

... More
Supply and Installation of Powdered coated box trays made of 2m thick GI sheet and top removable cover for - 200 x 75 x 2 mm

10

-

-

... More
Supply and Installation of Powdered coated box trays made of 2m thick GI sheet and top removable cover for - 300 x75 x 2 mm

10

-

-

... More
ASSOCIATED ACCESSORIES Supply and fixing of 2mm thick PVC & 1.6mm thick MS conduit of various dia., exposed or concealed, with all accessories, Wall chasing, finishing, fish wire, etc., as directed by the departmental officers and the brand should got approval. (Exposed Conduiting - MS & Concealed Conduiting - PVC)

-

-

-

... More
Supply and Fixing of 32mm dia 2mm thickness

50

-

-

... More
Supply and Fixing of 25mm dia 2mm thickness PVC Conduits

50

-

-

... More
Supply and Fixing of 20mm dia 1.6mm thickness MS Conduits

250

-

-

... More
Supply and Fixing of 25mm dia 1.6mm thickness MS Conduits

250

-

-

... More
Supply and Fixing of 32mm dia 1.6mm thickness MS Conduits

175

-

-

... More
Supply, fabrication and installation of MS structural supports including welding, bolting, riveting, supply of necessary anchor bolts and grouting etc, supply of paint and applying one coat of anti rust primer and two finished coats of approved synthetic enamel paint including breaking walls, floors etc. for structures as required including supply of all GI hardware materials, including all labour and materials as per approved drawings, specifications of this tender and directions of Engineer-in-Charge.

3

-

-

... More
Supply and arranging for Temporary Power Supply for lighting and other contract agencies at site including sufficient no of tube light fittings, sufficient no. of plug points with plug tops with adequate distribution boards and all other necessary safety devices like elcb, etc., to ensure safe and continued supply at site. up to end of the project. as directed by the departmental officers and the brand should be got approval.

1

-

-

... More
Supply & installation of 150mm wide x 100mm depth MS Powder coated 18G DB cabinet/Camouflaging

20

-

-

... More
Supply & installation of 150mm Dia Half cut Hume pipe with connected accessories

10

-

-

... More
Supply & installation of 200mm Dia Half cut Hume pipe with connected accessories

80

-

-

... More
Supply & installation of 300mm Dia Half cut Hume pipe with connected accessories

10

-

-

... More
SHOP DRAWINGS, INSPECTION AND APPROVALS

-

-

-

... More
Preparation & submission of applications, Liasioning with EB for getting addtional Load sanction, all necessary co-ordination upto completion of the project.

1

-

-

... More
Preparation of CEIG drawings, Liasioning with CEIG for getting drawing approval, arranging inspection, getting safety certificate & preparation& submission of AS BUILT drawings. Four Sets of paper print of as built drawings& a soft copy of these drawings to be submitted to the clients while completion. (All statutory fees to be paid in this regard will be reimbursed by the client on submission of receipt & should not be included in this item). Including DG sets approvals.

1

-

-

... More
LA & EARTH FLAT BUS

-

-

-

... More
All installation works should be as complete and as directed by Employer / Employer's representative.

-

-

-

... More
The rate includes necessary connected minor civil works if required and necessary supports as required at site. No extra payment will be made for the same.

-

-

-

... More
Supply, fixing of following materials for lightning arrestor system. The rate includes necessary accessories like 'Wood screws, plastic dowels, cross connector, expansion piece, clamps, suitable concrete base part with cover for fixing air terminal, conductors holder at wall / roof/ ACP etc. and all connected minor civil works if required and necessary supports as required at site. No extra payment will be made for the same.

-

-

-

... More
8 mm Aluminium Round Conductor

8600

-

-

... More
Air Terminal 3 Meter

28

-

-

... More
Air Terminal 4 Meter

28

-

-

... More
Down Conductor 8 mm Aluminium

950

-

-

... More
Test link (at every down conductor)

28

-

-

... More
GI Strip (25x6 mm)

780

-

-

... More
Earthing: C-Bar 3/4" dia, UL listed, 3000 mm long + 22.6 Kg GC+ and clamp for termination. Including 750mm x 750mm x 3mtr long excavation and construction of 850mm x 850mm x 300 mm high brick wall chamber with cement mortor. The chamber shall be provided with 450mm x 450mm x 10mm cast iron / RCC cover with frame and lockable facility. The Cover shall be heavy duty to suit heavy vehicle movements.

28

-

-

... More
Supply & Laying of 50x6mm GI. Flat for grounding connections in supports,trays,surface , using necessary fixing materials,insulators at regular intervals as required. The cost shall include minor civil works.

601.5

-

-

... More
Supply & Laying of 50x6mm CU. Flat for grounding connections in supports,trays,surface , using necessary fixing materials,insulators at regular intervals as required. The cost shall include minor civil works.

315

-

-

... More
Supply & Laying of 25x6mm CU. Flat for grounding connections in supports,trays,surface , using necessary fixing materials,insulators at regular intervals as required. The cost shall include minor civil works.

105

-

-

... More
Supply & Laying of 25x3mm GI. Flat for grounding connections in supports,trays,surface , using necessary fixing materials,insulators at regular intervals as required. The cost shall include minor civil works.

100

-

-

... More
Supply & Laying of 25x6mm GI. Flat for grounding connections in supports,trays,surface , using necessary fixing materials,insulators at regular intervals as required. The cost shall include minor civil works.

3318

-

-

... More
Supply & Laying of 6 Sq.mm. Cu. Wire for grounding connections in supports,trays,surface , using necessary fixing materials,insulators at regular intervals as required. The cost shall include minor civil works.

735

-

-

... More
Supply & Installation of Busbar of 0.5 Mtr length made out of 50x6 mm GI strip with drill holes of M8 at 25mm interval mounted on insulators with Enclosure Box with visible glass

0.1

-

-

... More
Supply & Installation of Busbar of 0.5 Mtr length made out of 25x6 mm GI strip with drill holes of M8 at 25mm interval mounted on insulators with Enclosure Box with front visible glass

15

-

-

... More
Supply & Installation of Busbar of 0.5 Mtr length made out of 25x6 mm Cu strip with drill holes of M8 at 25mm interval mounted on insulators with Enclosure Box with front visible glass

14

-

-

... More
Supply,installation, testing and commissioning of GI Pipe Electrode Earthing System:Pipe Earth Electrode using 38 mm dia class B GI pipe complete as per IS 3043 with salt, charcoal, brick masonary chamber with heavy duty RCC cover (suitable to take fire tender load) tender truckmovement) of 450mm x 450mm x 300mm chamber. (Earth strip to be left upto the Earthpit for Connection) The rates shall include excavation of the pit, construction of masonry chamber, providing heavy duty concrete cast slab, painting & making etc.,& as per the technical specification. The supporting pipe, funnel sizes, etc as per NBC. (ASHLOK, CAPE, JEF EARTHING)

52

-

-

... More
Supply,installation, testing and commissioning of Copper plate Electrode Earthing System:Plate Earth Electrode using 19 mm dia  Class B  copper plate of size 600 x 600 x 3 mm thick.with heavy duty RCC cover (suitable to take fire tender truck load) of 450mm x 450mm x 300mm chamber.(Earth strip to be left upto the Earthpit for Connection) The rates shall include excavation of the pit, construction of masonry chamber, providing heavy duty concrete cast slab, painting & making etc.,& as per the technical specification. The supporting pipe, funnel sizes, etc as per NBC.

16

-

-

... More
UPS & BATTERY

-

-

-

... More
Design, manufacture, assembly, supply, installation, testing, delivery and commissioning of 15 kVA (Continuous rating) online, double conversion operating on conventional mode 3 ph input and 3 ph output UPS system with IGBT rectifier without isolation transformer as per technical specifications. complete with all accessories and fire/over temperature detection, control/Display panel & energy optimization feature. The system shall be housed in sheet steel enclosure fabricated out of standard thickness. The enclosure with IP 20 protection shall have ventilation fans on top , provision for cable entry from bottom and remote alarm panel compatibility. The unit shall have BACnet IP communication interface. The quoted rate shall be inclusive of the tests and all other accessories specified in technical specification. The THD of UPS units shall be less than 3%. (For COMMAND CENTER)

2

-

-

... More
Supply, installation, testing and commissioning of Battery banks of requisite quantity and AH rating suitable for 15 kVA (Continuous rating) online, double conversion UPS system with one suitably rated DC circuit breaker on each string with all necessary nterconnecting links and interconnecting copper cables for each of above UPS units with 90 minutes back up at rated load. Battery shall be of the sealed maintenance free Valve Regulated Lead Acid (VRLA) stationary type 12V blocks conforming to technical specification.

2

-

-

... More
Design, manufacture, assembly, supply, installation, testing, delivery and commissioning of 40 kVA (Continuous rating) online, double conversion operating on conventional mode 3 ph input and 3 ph output UPS system with IGBT rectifier without isolation transformer as per technical specifications. complete with all accessories and fire/over temperature detection, control/Display panel & energy optimization feature. The system shall be housed in sheet steel enclosure fabricated out of standard thickness. The enclosure with IP 20 protection shall have ventilation fans on top , provision for cable entry from bottom and remote alarm panel compatibility. The unit shall have BACnet IP communication interface. The quoted rate shall be inclusive of the tests and all other accessories specified in technical specification. The THD of UPS units shall be less than 3%. (For Security & office related power points)

1

-

-

... More
Supply, installation, testing and commissioning of Battery banks of requisite quantity and AH rating suitable for 40 kVA (Continuous rating) online, double conversion UPS system with one suitably rated DC circuit breaker on each string with all necessary nterconnecting links and interconnecting copper cables for each of above UPS units with 30 minutes back up at rated load. Battery shall be of the sealed maintenance free Valve Regulated Lead Acid (VRLA) stationary type 12V blocks conforming to technical specification.

1

-

-

... More
Design, manufacture, assembly, supply, installation, testing, delivery and commissioning of 10 kVA (Continuous rating) online, double conversion operating on conventional mode 3 ph input and 3 ph output UPS system with IGBT rectifier without isolation transformer as per technical specifications. complete with all accessories and fire/over temperature detection, control/Display panel & energy optimization feature. The system shall be housed in sheet steel enclosure fabricated out of standard thickness. The enclosure with IP 20 protection shall have ventilation fans on top , provision for cable entry from bottom and remote alarm panel compatibility. The unit shall have BACnet IP communication interface. The quoted rate shall be inclusive of the tests and all other accessories specified in technical specification. The THD of UPS units shall be less than 3%. (For Emergency lighting )

1

-

-

... More
Supply, installation, testing and commissioning of Battery banks of requisite quantity and AH rating suitable for 10 kVA (Continuous rating) online, double conversion UPS system with one suitably rated DC circuit breaker on each string with all necessary interconnecting links and interconnecting copper cables for each of above UPS units with 90 minutes back up at rated load. Battery shall be of the sealed maintenance free Valve Regulated Lead Acid (VRLA) stationary type 12V blocks conforming to technical specification.

1

-

-

... More
BATTERY RACK Supply and installation of Battery Rack of epoxy painted sheet steel suitable for above mentioned UPS battery banks rating with separate compartment for circuit breaker. Each rack shall be supplied with 150mm high MS base stand . Cost includes of fabricated MS frame approximately 300mm height suitable for UPS Battery. The design of stool shall ensure uniform distribution of weight of 400kg/Sqm

-

-

-

... More
40 KVA

2

-

-

... More
30 KVA

2

-

-

... More
10 KVA

1

-

-

... More
MISCELLANEOUS ITEMS

-

-

-

... More
Supply of AC Chargeable Emergency Lamp 2 x 11W LED Lamp with all connected accessories

1

-

-

... More
Supply and installation of 2m x 1m Rubber Mat suitable for 11 KV installation confirming to IS

14.7

-

-

... More
Supply and installation of framed first aid chart (English & Local language) in panel room

18

-

-

... More
Supply and installation of First Aid Box complete with all First Aid Medicines

18

-

-

... More
Supply and installation of Shock Treatment Chart fixed in glass frame

18

-

-

... More
Supply of Hand Gloves 11KV Grade

3

-

-

... More
Supply & installation of 11 KV Danger boards

11

-

-

... More
Supply & installation of 440V Danger boards

20

-

-

... More
Supply & installation of 4 Nos. Fire Buckets made out of 40 x 40 x 6mm MS Angle

3

-

-

... More
Supply and installation of Fire Extinguisher Co2, 4.5 kg. confirming to TAC Norms

16

-

-

... More
Supply and installation of framed, Laminated SLD in Electrical rooms

18

-

-

... More
Supply & Installation of HT / LT cable route marker complete as per Latest Standards & regulations

21

-

-

... More
Supply of 2 hour fire rated fire retardant material sealing (UL Listed) all electrical ducts and openings made in the slab / wall / partition to take conduits / cable trays / raceways etc as required complete / as directed by the site incharge

36

-

-

... More
Supply & Installation of Double wall corrugated HDPE pipes of 6 Kg/Cm2 working pressure   including all accessories i.e. flanges as required of following sizes

-

-

-

... More
Supply & Installation of Double wall corrugated HDPE pipes of of 6 Kg/Cm2 working pressure   including all accessories i.e. flanges as required of 50 mm OD with 3.6 mm wall

15

-

-

... More
Supply & Installation of Double wall corrugated HDPE pipes of 6 Kg/Cm2 working pressure   including all accessories i.e. flanges as required of 100 mm OD with 5.5 mm wall

50

-

-

... More
Supply & Installation of Double wall corrugated HDPE pipes of 6 Kg/Cm2 working pressure   including all accessories i.e. flanges as required of 160 mm OD with 7.7 mm wall

20

-

-

... More
Supply & Installation of Double wall corrugated HDPE pipes of of 6 Kg/Cm2 working pressure   including all accessories i.e. flanges as required of 300mm OD with 12.0 mm wall

20

-

-

... More
Battery Charger - Indoor Supply, Receive, unloading at site of 3Phase input and Single Phase Output, 110V/24V DC, 40A Battery Charger with Float & Boost charging, 100AH, 2 Volts DC Sealed Maintenance Free Batteries complete with all accessories like insulators, clamps, bimetal connectors, M.S.support rack as required.

1

-

-

... More
Design, Supply, Loading, Unloading, Installation, Testing & Commissioning of façade lighting

-

-

-

... More
Supply, Installation, Testing and Commissioning of LED Striplight Outdoor RGBW(W=3000K), IP67, 19.2W/m, 5000mmx12mmx2mm, 24V, 19.2W/m, with L7050000 Burning Hours and 5 years Warranty

700

-

-

... More
Supply, Installation, Testing and Commissioning of CV DMX RDM Decoder - 4 channel, 8Amp, DMX512/RDM CV Decoder

279

-

-

... More
Supply of Surface Mount Aluminum Profile and PC diffuser with Endcap and Mounting clip (2 sets/M).W: 16mm X H: 18mm Standard length -3 meter.

1167

-

-

... More
Supply, Installation, Testing and Commissioning of 250W 24V Constant Voltage Outdoor Driver

269

-

-

... More
Supply, Installation, Testing and Commissioning of 75W 24V Constant Voltage Outdoor Driver

10

-

-

... More
Supply, installation, testing and commissioning of compact DMX signal splitter that takes the incoming DMX512/RDM signal and amplify the signal and supporting bi-directional communications for discovery, addressing and DMX control of light fixtures.This unit takes the incoming DMX/RDM signal and splits the signal into six separate output channels allowing for expanding the number of devices controlled from 32 to 6 X 32. The output terminals are electronically isolated from the input & RDM-through port and share a common ground reference. All six output ports have an independent output driver to boost the DMX/RDM signal. The maximum power consumption shall be less than 4.5W and input voltage shall be 12-24V DC.

60

-

-

... More
Design, Supply, Loading, Unloading, Installation, Testing & Commissioning of 130kW SOLAR ROOFTOP SYSTEM

-

-

-

... More
Design, Supply, Loading, Unloading, Installation, Testing & Commissioning of Solar PV Modules of Minimum 550 Wp. It can be either Mono to match the efficiency and Minimum efficiency should be 19%

240

-

-

... More
Design, Supply, Loading, Unloading, Installation, Testing & Commissioning of Solar generation meter - (Unidirectional type, Immediate to LT panel) as per TANGEDCO norms

1

-

-

... More
Design, Supply, Loading, Unloading, Installation, Testing & Commissioning of 33kv net meter (Bidirectional) procurement and approvals as per TANGEDCO norms

1

-

-

... More
Design, Supply, Loading, Unloading, Installation, Testing & Commissioning of Remote Monitoring system of Solar PV Power plant with necessary communication system setup

1

-

-

... More
Design, Supply, Loading, Unloading, Installation, Testing & Commissioning of Inverter- Three Phase, BIS approved - String Inverter, 130kW (Combination of single or multiple Inverter)

1

-

-

... More
Design, Supply, Loading, Unloading, Installation Commissioning of Module Mounting Structure (MMS)-Front and Back post type alongwith HDGI type with GI (Minimum 85 Micros) ,SS fasteners, uPVC Conduit pipes, Cable Tray , MC4 Connectors (pair set) and others like DC+AC Consumables ( Earthing Cables, Cable tie, markers, MC4 Crimping tool, Ferrules etc), Anti corrosion material should be used.

1

-

-

... More
Design, Supply, Loading, Unloading, Installation, Testing & Commissioning of String Cable (Inverter at Roof top itself) - 4 sqmm cable as required

1

-

-

... More
Design, Supply, Loading, Unloading, Installation, Testing & Commissioning of DC Distribution Board /Panel - Based on design, DC Fuse and SPD Type II

1

-

-

... More
Design, Supply, Loading, Unloading, Installation, Testing & Commissioning of AC Distribution Board /Panel - as per design topology, with SPD-AC - Indoor type

1

-

-

... More
Design, Supply, Loading, Unloading, Installation, Testing & Commissioning of Earthing system as required

1

-

-

... More
Design, Supply, Loading, Unloading, Installation, Testing & Commissioning ofAC cable FRLS -3C X 185 sqmm, Aluminium ,XLPE

1

-

-

... More
Design, Supply, Loading, Unloading, Installation, Testing & Commissioning ofEnd termination glands as required as per design

1

-

-

... More
Design, Supply, Loading, Unloading, Commissioning of Civil work for MMS as required as per Site conditions

1

-

-

... More
Safety Items, First Aid Box and Posters

1

-

-

... More
CEIG approval for Solar system

1

-

-

... More
Feasibilty, Statuary approvals and Coordination with TANGEDCO for Solar PV plant till commissioning

1

-

-

... More
SITC OF DG SETS

-

-

-

... More
Supply, Loading, Unloading, Installation & Commissioning as desired by Engineer-in-charge, Testing and Commissioning of 2250 KVA prime rating diesel generating set comprising of radiator cooled engine with electronic governer with synchronisation provision with auto start/stop and with all accessories as per specification coupled to 2250 KVA 0.8PF, 415V, 3 PHASE,4 WIRE, 50HZ brushless type alternator (as per the specification) mounted on common base frme with outdoor acoustic enclosure, suitable exhaust arrangement, Auto start /stop Panel and along with all required accessories. All the gauges - pressure, temperature etc. should be analogue type only with auxiliary output which can be directly monitored on the control and power panel and an external BMS as per the attached specifications and data sheets.1No 4000A TPN 50kA ACB to be provided inside the enclosure as a local isolation with interconnection arrangement with including the following items etc., The D.G. sets shall be inclusive of but not limited to the following standard accessories: Radiator Fan cooling system Fly Wheel to suit flexible/rigid coupling Fly wheel housing complete with starter gear ring and coupling Fuel hoses Electronic Governor Air Cleaner with Vacuum Indicator Fuel and Lube Oil Filter By pass filter Fuel Pump PT Type Water Pump Lube Oil Pump Electric Starter 24 Volts DC Battery Charging Alternator with Built-in-regulator - 24 Volts, 50 Amps. and battery stand

-

-

-

... More
Safety Control against low lube oil pressure, over speed and high cooling water temperature along with tripping Vibration Dampers Lube Oil Cooler Flue pipe of required size from DG set FLUE OUTLET up to Silencer Residential Silencer Expansion bellow -( suitable size SS bellows) Anti Vibration Pads with spring vibration Isolator First fill of Lube Oil (Castrol/HPL/IOCL) and Coolant qty as per engine requirement Control Panel with Synchronisation and load sharing option Sync. Controller & Control Cabling as Standard System Integration (b/w Dg set on Synch controller) Batteries with battery leads along with battery stand

-

-

-

... More
DG SET WITH ACOUSTIC ENCLOSURE Latest CPCB 4+ norms should be followed.

-

-

-

... More
2250 KVA DG SET WITH ACOUSTIC ENCLOSURE

2

-

-

... More
Engine Mounted ACB enclosures:

-

-

-

... More
Design, Supply, Loading, Unloading, Installation, Testing & Commissioning of DG isolator Panel As per SLD shall be mounted on the alternator with necessary supports, anti-vibration connections, mounting brackets, MS stand, clamps etc. and suitable size of flexible copper bus bars / univyn cables between DG alternator terminal to the box along with 4000A 4 Pole ACB.

2

-

-

... More
Design, Supply, Loading, Unloading, Installation, Testing & Commissioning of day fuel tank (990 litres) for each DG set. The day fuel tank shall be fabricated from 2 mm thick MS sheets and shall include the cost of removable cover with locking arrangement, the cost of painting, the cost of providing all the required appurtenances like inlet & outlet connection, float valves, drain connection, oil level indicator and low level/high level alarms and the cost of support arrangement. complete as per specification and as required. Level indicator shall be compatible to BMS integration.

2

-

-

... More
Piping for fuel System:

-

-

-

... More
Suppply & Installation of piping (Heavy Duty Class- 'C') MS ASTM 106 grade B schedule 40 seamless pipe with all accessories/ fittings such as bends,tees unions etc, including necessary G.I. supprts, cutting, welding, Painting with one coat of primer and two coats of enamel paint of approved make. The quoted rate to include all necessary hardware, electrostatic jumpers for all flange joints, Cost of all necessary flanges/matching flanges,Reducers for suction & delivery lines to be included i) G.I. Supports, brackets for piping with all joints, supports etc. ii) installation of pipes in hume pipe laid for road crossing , trenches in DG , External trench with all necessary accesories for its complete installation as per IS standrads.

-

-

-

... More
Suppply & Installation of piping (Heavy Duty Class- 'C') MS ASTM 106 grade B schedule 40 seamless pipe 40 mm dia with all accessories/ fittings such as bends,tees unions etc

20

-

-

... More
Suppply & Installation of piping (Heavy Duty Class- 'C') MS ASTM 106 grade B schedule 40 seamless pipe 50 mm dia with all accessories/ fittings such as bends,tees unions etc

100

-

-

... More
Ball valves

-

-

-

... More
Suppply & Installation of 25 mm Dia Ball Valves with connected all accessories

3

-

-

... More
Suppply & Installation of 50 mm Dia Ball Valves with connected all accessories

15

-

-

... More
Design, Supply, Installation, Testing and Commissioning of Level switch/Transmitter with provision of connect to PLC/BMS system in intermediate /over flow day tanks

-

-

-

... More
Butterfly Valve as per the specification for following dia

-

-

-

... More
Suppply & Installation of 80 mm dia Butterfly Valve with connected all accessories

3

-

-

... More
Suppply & Installation of 65 mm dia Butterfly Valve with connected all accessories

3

-

-

... More
Non Return Valve as per the specification for following dia

-

-

-

... More
Suppply & Installation of 80 mm dia Non Return Valve with connected all accessories

2

-

-

... More
Suppply & Installation of 65 mm dia Non Return Valve with connected all accessories

2

-

-

... More
Suppply & Installation of 50 mm dia Non Return Valve with connected all accessories

2

-

-

... More
Suppply & Installation of 40 mm dia Non Return Valve with connected all accessories

2

-

-

... More
Suppply & Installation of 25 mm dia Non Return Valve with connected all accessories

2

-

-

... More
Suppply & Installation of Strainer with connected all accessories

2

-

-

... More
Suppply & Installation of Flow Meter 38 MM with connected all accessories

2

-

-

... More
Suppply & Installation of Flow Meter 50 mm with connected all accessories

3

-

-

... More
Suppply & Installation of Roto Del GearFlame Proof Motor HG 75 with connected all accessories

2

-

-

... More
Suppply & Installation of High low level Sensor 3 Stage with connected all accessories

4

-

-

... More
Suppply & Installation of High low level Sensor 2 Stage with connected all accessories

4

-

-

... More
FSuppply & Installation of loat Valve with connected all accessories

4

-

-

... More
Retrofit Emission control device suitable for 2250 KVA, 415 Volts prime rating diesel generating set, as per the commission for air quality management and their recent directions, RECD should match the emission control criteria, Smoke shall not exceed prescribe value throughout the operating load points of the test cycle, as per the latest directions by CAQM/State pollution control board/CPCB & NGT suitable for 2250 KVA, 415 volts DG set. RECD shall have no effect on exhaust back pressure. The back pressure shall be maintained within prescribed limit by the manufacturer. There should not be any backflow from RECD to engine exhaust system. Type Approval of RECD for family of DG Sets should be as per CPCB instructions and the same has to be obtained from the CPCB prescribed labs . Any other equipments required with RECD to comply the CAQM criteria required to be consider in this Item only.The RECD shall be certified by one of the approved & recognised agencies by the central air pollution control board. RECD should have IoT based controller to remotly measure the parameters by the pollution control board website directly as and when required, also should have communication port for BMS through backnet over IP with open protocol connectivity. Retrofit Emission Control device (RECD) in suitable weather proof canopy with suitable provision for termination of IN and OUT of exhaust pipes ( including the manifolds if required for connection) to meet the local standards etc. The system shall be complete with all accessories including cabling, termination, outdoor MCC panel including necessary power cabling , earthing etc. as per the technical specification (IF THIS ITEM IS NOT REQUIRED BY THE VENDOR & THEY ARE FULFILLING THE LATEST CAQM CRITERIA OF EMMISSION CONTROL, THEN CONFRIMATION FROM OEM SHALL BE SUBMITTED)

2

-

-

... More
Self-supporting M.S Class B or 5mm thick DG Exhaust Pipes as specified & complete with all M.S supporting structures, sampling point, two coats of red oxide and anti corrosive painting, necessary anti-vibration supports, floor brackets, required insulation of 100mm thickness having density of 48 Kg/ M3 wrapped in chicken mesh and cladding as with 24 gauge alluminium sheet specified including erection. Expansion bellows shall be provided at necessary location. The diameter of the exhaust pipe has to be decided by DG vendors considering the horizontal and vertical length, bends involved to take required height for discharge as per CPCB norms.Back pressure calculation has to be submitted by DG vendor and get approved from Engineers incharge. Latest CPCB norms should be followed.

-

-

-

... More
Suppply & Installation of 400mm dia. Exhaust Pipe

2

-

-

... More
Suppply & Installation of 500mm dia. Exhaust Pipe

2

-

-

... More
Suppply & Installation of 600mm dia. Exhaust Pipe

70

-

-

... More
Supply, Fabrication, Commissioning and Erection of Silencer Insulation 50mm thick lightly resin bonded (LRB) rock wool (64 Kg/m3 density) insulation clad with 26 SWG aluminium sheet cladding.

2

-

-

... More
Supply, Fabrication, Commissioning and Erection of MS steel structure & painting with two coats of primer zinc oxide and two coats of approved enamel paint. All MS supports shall be measured in this line item (Cable tray, DG Stack, DG room Accoustic & DG day tank Supports) Quoted price shall be inclusive of Supporting arrangement at all levels & for the metal deck slab shall be with Wedge/ Gripple / Lindapter / fischer fixing arrangement for TR 60 / TR 80 metal decks. (Vendor has to submit Structural design calculation and all necessary supports within the building area shall be reviewed and confirmed by Consultant before execution.

16

-

-

... More
Supply, Fabrication, Commissioning and Erection of SS flexible bellows-300 mm dia

4

-

-

... More
Supply, Fabrication, Commissioning and Erection of SS flexible bellows-500 mm dia

2

-

-

... More
Design, manufacture, testing at works, Supply, Installation, Testing and Commissioning of Indoor type LT Switchboards, Floor mounting type, Top busduct entry. Enclosure: Compartmentalized CRCA sheet with Single front, free standing, front hinged, rear removable, extendable on both sides, dust & vermin proof, cubicle type, floor mounted (with base channel), undrilled gland plates at top/bottom Doors:2mm Body:2mm Gland:3mm covers and partitions:1.6mm IP class:IP52 for Indoor/IP55 with weather proof enclosure for outdoor Bus bar Material: As per BOQ Bus bar supports: DMC/FRP/SMC Bus bar joints: Shrouded/Tinned Ics=Icu for all breakers Loovers: Busbar chamber shall have louvers with fine mesh inside Shade: Epoxy powder coated RAL 7032 Bus bar insulation: Aluminum bus bars shall be bare with color coding at the ends/Copper shall be bare with color coding at the ends/For Humidified areas the copper bus bars shall be coated with tin. Two dissimillar materials are joined with bi metalic washer.

-

-

-

... More
1. The Panel shall be fully as per the requirement of Electrical Inspectorate/ EB authorities. 2. Auxilliary contactor to be provided along with auto-manual switch where ever required. 3. All feeders shall have LED RYB and 'ON / OFF / TRIP' indications. 4. CTs shall be cast resin type only. 5. All doors to have double rubber gasket with shutter assembly & door seating frame. 6. The current density for Aluminium busbars shall be 0.8/sq.mm only. 7. The current density for Copper busbars shall be 1.2/sq.mm only. 8. All meters shall be Digital type with RS 485 port only. 9. FRLS PVC copper wires shall be used for control wiring 10. SPD shall be class B(125KA) for main panels & Class B+C(40KA) for sub panels of 3phase 4wire system (Phase - Neutral & Neutral to Earth). Class B+C unless otherwise specified as per mentioned in the Panel. 11. Multi function meter with suitable rated CTs should be provided for all outgoing feeders as per mentioned in the Panel SLD. a. 2 No – MFM Meter - Cl1 accuracy with LED Display with RS485 port for I/C feeders (WL 5010 or equivalent) Paramters: 1. 128 samples / cycle b. Running demand, max demand, prediction demand in single page window Features c. V, A, F, kW, KVA, kVAr, kWh, kVAh, kVArh, PF, Runhr, Onhr, Interrupts,Phase angle, THD, Neutral current, Max Demand (with RTC) d. Bi-directional (Import-Export) e. Events (high-low) with time stamp f. Individual Harmonics upto 31st

-

-

-

... More
12. All CTs should be provided for shorting link 13. All incoming and outgoing air circuit breakers shall be placed on middle portion of the vertical in single tier formation. 14) DG Sync. Panel: ACB models shall be as per tender specifications. 15. Panel shall be as per OEM system Integrator ( IEC 61439) type tested approved design. 16. Phase Sequence for DG & Busducts shall be matched with panel complete with flange end. Panel vendor to coordinate with DG & Bus duct vendor for its termination arrangement in Panels, so that appropriate compartment can be designed. 17. Space heater with thermostat needs to be provided for all the panels. 18. Earthing of all components, frame etc. to a common internal earth busbar.

-

-

-

... More
PLC WITH SCADA SYSTEM & HMI

-

-

-

... More
PLC along with 10" HMI display unit shall be considered. The vendor / contractor has to make sure that panel is delivered along with the PLC. No additional cost will be entertained after the delivery of panels. D.G vendor has to download the upgraded software at free of cost (at least 5 times) till 100% load come on the system. The necessity of the upgrading the software and its setting will be depending on the load at which the DG sets synchronize and run. So at different loads the upgraded software has to be uploaded and will be done by the DG vendor at free of cost. The PLC shall include the following functions AMF operation with provision for manual operation PLC shall operate as per the sequence of operation that is indicated in the drawing. Necessary I/0's that are required to function PLC as per the intended operations to be generated by Vendor and approved from consultant. Auto Synchronization Auto Load sharing among DG sets Auto load balancing and load management with Load based Start / Stop Incoming and outgoing breaker interlocking, Neutral contactor interlocking logic & fire interlocks, provision for integration with fire system, and operating logic during fire condition. SCADA system with necessary hardware, graphical software, interface & communication cards and relays, CPU, Monitor, power supply unit cabling from PLC in the DG sync panel to SCADA CPU and monitoring system. All the incoming and outgoing breakers ON/OFF TRIP status, All the meters shall be wired and integrated into the PLC & HMI display unit. A common RS485 comm port shall be provided in the HMI for BMS connectivity. PLC shall be built in one of the vertical section in the DG Synchronizing panel. Suitable built in power supply unit along with battery back up shall be considered for PLC. 20% spare IO's shall be considered in the PLC HMI with touch screen to indicate all breaker status, engine status and including SLD to be part of DG synch. Panel. This touch screen shall have RS485 port for BMS connectivity.

-

-

-

... More
Note : Refer the SLD

-

-

-

... More
Supply, design, testing and installation of Adaptor box suitable for 2250kVA DG set connecting alternator terminals to Isolator incomer by copper flexibles / univyn cables. The adopter box shall have adequate space for mounting CT's for REF & Differential protection relays. The adaptor box shall be mounted on the alternator with necessary supports, anti-vibration connections, mounting brackets, MS stand, clamps etc. to mount the adaptor box shall be included in the price. No extra claim is entertained. Price shall be inclusive of suitable size of flexible copper bus bars / univyn cables between DG alternator terminal to the adapter box. Note : CT's for REF & Differential protection will be loose supply from the DG Vendor Panel manufacturer and installation at DG side shall be carried out by DG vendor.

2

-

-

... More
Supply of CT's for REF (restricted earth flow) & Differential protection at both DG terminals side and DG incomer side in the DG Synchronizing panel. CT's shall be Class PS, 4000/5A, 10VA. Calculations for Vk and Image to be furnished and shall be co-ordinated with CT's in the Synchronizing panel. DG Synch. Panel vendor to supply to DG vendor. DG Vendor to make the space provision for installing the REF CT in neutral terminal and Differential CT's in RYB terminals.

2

-

-

... More
DG Synchronizing Panel including PLC WITH SCADA SYSTEM for auto load sharing, auto synchronizing and mimic diagram.

1

-

-

... More
AUTOMATIC FIRE DETECTION AND SUPPRESSION SYSTEM WITH Novec 1230/ FK5-1-12 GAS & Complete - For DG Synchronizing Panel

1

-

-

... More
CONTROL CABLES

-

-

-

... More
Supply , laying of 1.1KV Grade FRLS Copper armoured Control Cabling inbetween Day oil tanks, DG Sync Panel/DG power Panel, Auxillary power panel, Sensing cables from utility power panels along with its end terminations inclusive of brass double compression glands and copper lugs for complete auto & manual control and logical operations. All necessay control cabling shall be considered under this line Item required for fully auto operation of entire DG & Fuel system. Supply & end termination of following CU FRLS armoured power/ control (shielded Signal) cables with necessary double compression brass glands, CU. terminal sockets, insulation tapes, fasteners, earthing clips & connecting the clip to main earth bus with suitable bare copper wire complete accessories as required

-

-

-

... More
Supply , laying of 24C x 1 sq. mm. YWY cable (From Alternator to DG Sync. Panel) cable on Wall / Trench with MS clamps

240

-

-

... More
Supply and fixing of brass cable gland and aluminium armoured cable with necessary aluminium cable sockets by crimping etc 24C x 1 sq. mm. YWY cable with earth connection

6

-

-

... More
Supply , laying of 12C x 2.5 sq. mm. YWY cable (From PCC to DG Sync. Panel) cable on Wall / Trench with MS clamps

180

-

-

... More
Supply and fixing of brass cable gland and aluminium armoured cable with necessary aluminium cable sockets by crimping etc for 12C x 2.5 sq. mm. YWY cable with earth connection

12

-

-

... More
Supply , laying of 10C x 2.5 sq. mm. YWY cable (From PCC to DG Sync. Panel) cable on Wall / Trench with MS clamps

180

-

-

... More
Supply and fixing of brass cable gland and aluminium armoured cable with necessary aluminium cable sockets by crimping etc for 10C x 2.5 sq. mm. YWY cable with earth connection

12

-

-

... More
Supply , laying of 6C x 2.5 sq. mm. YWY cable (From Alternator to DG Sync. Panel) cable on Wall / Trench with MS clamps with earth connection

180

-

-

... More
Supply and fixing of brass cable gland and aluminium armoured cable with necessary aluminium cable sockets by crimping etc for 6C x 2.5 sq. mm. YWY cable with earth connection

12

-

-

... More
Supply , laying of 4C x 2.5 sq. mm. Cu. Flexible cable (Shielded - From PCC to PCC) cable on Wall / Trench with MS clamps

90

-

-

... More
Supply and fixing of brass cable gland and aluminium armoured cable with necessary aluminium cable sockets by crimping etc for 4C x 2.5 sq. mm. Cu. Flexible cable with earth connection

6

-

-

... More
Supply , laying of 4C x 2.5 sq. mm. YWY cable (From PCC to DG Sync. Panel + From LTA Pump to DG Sync. Panel) cable on Wall / Trench with MS clamps

360

-

-

... More
Supply and fixing of brass cable gland and aluminium armoured cable with necessary aluminium cable sockets by crimping etc 4C x 2.5 sq. mm. YWY cable with earth connection

18

-

-

... More
Supply , laying of 3C x 2.5 sq. mm. YWY cable (From PCC to PCC) cable on Wall / Trench with MS clamps

180

-

-

... More
Supply and fixing of brass cable gland and aluminium armoured cable with necessary aluminium cable sockets by crimping etc 3C x 2.5 sq. mm. YWY cable with earth connection

6

-

-

... More
Supply , laying of 2C x 4 sq. mm. YWY Cable (From Battery to DG Sync. Panel) cable on Wall / Trench with MS clamps

180

-

-

... More
Supply and fixing of brass cable gland and aluminium armoured cable with necessary aluminium cable sockets by crimping etc for 2C x 4 sq. mm. YWY Cable with earth connection

6

-

-

... More
Supply , laying of 2C X 2.5 Sq. mm YWY cable cable on Wall / Trench with MS clamps

90

-

-

... More
Supply and fixing of brass cable gland and aluminium armoured cable with necessary aluminium cable sockets by crimping etc for 2C X 2.5 Sq. mm YWY cable with earth connection

2

-

-

... More
CABLE TRAY

-

-

-

... More
Supply, fabrication, installation & painting of Hot Dip galvanized Ladder cable racks / trays of up to 300 ( 1.6mm thickness ) & more than 300mm up to 750mm (2 mm thickness) more than or equal to 1000mm ( 2.5 thickness) with necessary painted G.I structural supports in horizontal or vertical formation & single / multitier formation as specified and shown on drawings. Up to 450mm - cable trays shall be supplied along with rod and C channel, refer specification. Above 450mm cable tray support shall be as per specification. The rate shall include GI supports, bends, Tees, all supporting brackets, anchor fasteners, screws, bolts, nuts etc. The Proper Floor supports need to be considered for the terrace floor cable tray as per the drawing.

-

-

-

... More
Supply, fabrication, installation & painting of Hot Dip galvanized Ladder cable racks / trays of up to 300 ( 1.6mm thickness ) - 150X50mm Cable Tray

20

-

-

... More
Supply, fabrication, installation & painting of Hot Dip galvanized Ladder cable racks / trays of up to 300 ( 1.6mm thickness ) - 200X50mm Cable Tray

20

-

-

... More
Supply, fabrication, installation & painting of Hot Dip galvanized Ladder cable racks / trays of up to 300 ( 1.6mm thickness ) - 300X50mm Cable Tray

20

-

-

... More
Supply, fabrication, installation & painting of Hot Dip galvanized Ladder cable racks / trays of up to 300 ( 1.6mm thickness ) - 450X50mm Cable Tray

80

-

-

... More
Supply, fabrication, installation & painting of Hot Dip galvanized Ladder cable racks / trays of up to 300 ( 1.6mm thickness ) - 600X75mm Cable Tray

20

-

-

... More
Supply, fabrication, installation & painting of Hot Dip galvanized Ladder cable racks / trays of up to 300 ( 1.6mm thickness ) - 750X75mm Cable Tray

20

-

-

... More
Supply, fabrication, installation & painting of Hot Dip galvanized Perforated cable racks / trays of up to 300 ( 1.6mm thickness ) & more than 300mm up to 750mm (2 mm thickness) more than or equal to 1000mm ( 2.5 thickness) with necessary painted G.I structural supports in horizontal or vertical formation & single / multitier formation as specified and shown on drawings. Up to 450mm - cable trays shall be supplied along with rod and C channel, refer specification. Above 450mm cable tray support shall be as per specification. The rate shall include GI supports, bends, Tees, all supporting brackets, anchor fasteners, screws, bolts, nuts etc. The Proper Floor supports need to be considered for the terrace floor cable tray as per the drawing.

-

-

-

... More
Supply, fabrication, installation & painting of Hot Dip galvanized Ladder cable racks / trays of up to 300 ( 1.6mm thickness ) - 150X50mm Cable Tray

60

-

-

... More
Supply, fabrication, installation & painting of Hot Dip galvanized Ladder cable racks / trays of up to 300 ( 1.6mm thickness ) - 225X50mm Cable Tray

60

-

-

... More
Supply, fabrication, installation & painting of Hot Dip galvanized Ladder cable racks / trays of up to 300 ( 1.6mm thickness ) - 300X50mm Cable Tray

20

-

-

... More
Supply, fabrication, installation & painting of Hot Dip galvanized Ladder cable racks / trays of up to 300 ( 1.6mm thickness ) - 450X50mm Cable Tray

20

-

-

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "bends" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.

-

-

-

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "bends" (galvanisation not less than 50 microns) - 150 mm width X 50 mm depth X 1.6 mm thickness

6

-

-

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "bends" (galvanisation not less than 50 microns) - 225mm width X 50 mm depth X 1.6 mm thickness

6

-

-

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "bends" (galvanisation not less than 50 microns) - 300 mm width X 50 mm depth X 1.6 mm thickness

3

-

-

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "bends" (galvanisation not less than 50 microns) - 450 mm width X 62.5 mm depth X 2.0 mm thickness

3

-

-

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Tee" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.

-

-

-

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Tee" (galvanisation not less than 50 microns) - 150 mm width X 50 mm depth X 1.6 mm thickness

3

-

-

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Tee" (galvanisation not less than 50 microns) - 225mm width X 50 mm depth X 1.6 mm thickness

3

-

-

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Tee" (galvanisation not less than 50 microns) - 300 mm width X 50 mm depth X 1.6 mm thickness

1

-

-

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Tee" (galvanisation not less than 50 microns) - 450 mm width X 62.5 mm depth X 2.0 mm thickness

1

-

-

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Cross member"(galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.

-

-

-

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Cross member"(galvanisation not less than 50 microns) - 150 mm width X 50 mm depth X 1.6 mm thickness

3

-

-

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Cross member"(galvanisation not less than 50 microns) - 225mm width X 50 mm depth X 1.6 mm thickness

3

-

-

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Cross member"(galvanisation not less than 50 microns) - 300 mm width X 50 mm depth X 1.6 mm thickness

1

-

-

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Cross member"(galvanisation not less than 50 microns) - 450 mm width X 62.5 mm depth X 2.0 mm thickness

1

-

-

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Reducer"(galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc as required.

-

-

-

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Reducer"(galvanisation not less than 50 microns) - 150 mm width X 50 mm depth X 1.6 mm thickness

3

-

-

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Reducer"(galvanisation not less than 50 microns) - 225mm width X 50 mm depth X 1.6 mm thickness

3

-

-

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Reducer"(galvanisation not less than 50 microns) - 300 mm width X 50 mm depth X 1.6 mm thickness

1

-

-

... More
Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray "Reducer"(galvanisation not less than 50 microns) - 450 mm width X 62.5 mm depth X 2.0 mm thickness

1

-

-

... More
Supplying and installation of Drip tray for fuel pipes. The cost shall include necessary supports, necessary clamping on each fuel pipe running in the drip tray.200 x 75mm dia floor mounted MS drip tray, running along the length of fuel storage room and as header for pipes to individual DG's. 100 x 75mm dia floor mounted MS drip tray, running from main header to individual DG's in DG room.

30

-

-

... More
VENTILATION / ACOUSTIC TREATMENT, EARTHING & GI EARTHING CONDUCTOR Supply , laying & termination of the following sizes of GI earth flats buried underground at 500mm from ground level / cable trays as per drawing & specification. All joints in the runs of the conductor shall be welded. For earth strips laid below ground, cost shall include necessary excavation, backfilling etc. including associated works

-

-

-

... More
Supply , laying & termination of - 75 x 10 mm GI earth flats

165

-

-

... More
Supply , laying & termination of - 75 x 6mm GI earth flats

30

-

-

... More
Supply , laying & termination of - 50 x 6mm GI earth flats

60

-

-

... More
Supply , laying & termination of - 25 x 6mm GI earth flats

100

-

-

... More
Supply , laying & termination of - 25 x 3mm GI earth flats

20

-

-

... More
CU EARTHING CONDUCTOR

-

-

-

... More
Supply , laying & termination of the following sizes of earth flats buried underground / laid in cable trays as per drawing & specification. All joints in the runs of the conductor shall be Brazed. For Earth strips laid below ground, cost shall include necessary excavation, backfilling etc. including associated works

-

-

-

... More
Supply , laying & termination of 75 x 10mm Cu. strip earth flats

350

-

-

... More
Supply , laying & termination of 50 x 6mm Cu. Strip earth flats

250

-

-

... More
Supply , laying & termination of 1C x 6sqmm MSCC FRLS PVC Copper wires

30

-

-

... More
Supply and installation of Earth pads made out of copper bus bars installed on 1100 V Insulators including hardware and other minor civil works. Associated works.

-

-

-

... More
Supply and installation of Earth pads made out of copper bus bars 500 x 75 x 10mm

3

-

-

... More
Supply and installation of Earth pads made out of copper bus bars 500 x 50 x 10mm

3

-

-

... More
Supply and installation of Earth pads made out of GI bus bars installed on 1100 V Insulators including hardware and other minor civil works. Associated works.

-

-

-

... More
Supply and installation of Earth pads made out of GI bus bars 500 x 75 x 6mm

3

-

-

... More
Supply and installation of Earth pads made out of GI bus bars 500 x 50 x 10mm

3

-

-

... More
Supply and installation of Earth pads made out of GI bus bars 300 x 25 x 6mm

3

-

-

... More
Manufacturing, supplying, fixing, testing and commissioning of automatic organic waste converter of 1000Kg/day Z type Modular Belt Conveyor Length 3000 mm, Width 300 mm MOC: SS frame, 1 HP Transtech Motor and Gear box without VFD with necessary platform and cover, Three phase electrical supply and vent to sewage or STP line, Rain protection. voltage 3pH 415/250 HZ, Power rating 27 Kw, Power Consumption 8. 5 Kw/hr. PLC Control System, Fully Automatic system. ORGANICO CER-250 OWC MACHINE TECHNICAL SPECIFICATIONS External Shredder: Stainless steel shaft with twin blades Grinding mechanism, Capacity: 50 - 250 kg/hr., 5 H.P motor with speed control, Vessel Chamber: Cylindrical vessel with U shaped at bottom Material: SS 304 Shaft: SS 304 with 10-12 rpm Inlet & outlet door: SS 304 Heating: Insulated heat jacket Heating temperature: 50 to 150 deg°Celsius Manure, heating temperature controller & moisture sensor, Aeration Blower Heavy duty motor Power: 0.25 Kw Body: CI (inner), Outer Body: SS outer body, Deodorizer To eliminate the odour Nano fiber Filter with activated carbon Outlet of blower connected to deodorizer SS body, Planetary Gear Box Motor Reduction gear box mechanism Auto lubrication Power rating:0.12KW, Control Panel VFD (variable Frequency Drive) controlled Fully automated PLC Temperature controller Moisture controller Proximity Switches. Warranty: 12 months from the date of supply, the cost including supplying of material, transportation charges, labour for installation etc., all complete.

1

-

-

... More
Supply and fixing of boom barriers combination of 1500 / 3000 / 6000mm boom length for 2W Entry 100% duty cycle, electro-mechanical type 24V Brushless DC Motor, micro-processor based barrier made of galvanised steel with powder coating housing - red housing with top white.using with spare room for devices. Lockable maintenance door and removable cover. It is mountable on the right or left side of the housing which is selectable. dormakaba has an opening/closing time of 1.5 to 5s. CE Certified, 5 Million cycles of operations tested, IP 54 Rated. It is persistent and robust with weather proof. Opening & Closing can be controlled by push button, photoelectric sensor for safety purposes. IN case of power failure, the barrier can be opened/closed mechanically. Operational Temperature - 30 deg C to +55 deg celcius. Power consumption of 40W. Dimensions of boom barrier housing - 340x290x1030mm Dimensions of boom - 3000mm IP rating: IP 54. Duty Cycle - 100%

8

-

-

... More
Supply and installation of 3 Normal lane + 1 Wider lane Sensor Swing Barrier:- (1) Two wings/door leaves are made of transparent polycarbonate with 10 mm thickness, upper edge 900 mm with opening/ closing time of 0.3 seconds minimum, which can be adjusted as per client requirement. (2) Design: The housing and the base columns are made of AISI 304 stainless steel with semigloss. Finish: Stainless steel semi-gloss smooth finish. (3) Function: The sensor barrier is equipped with two servo positioning drives (low energy drives with energy content 1.6 joules) along with Tooth holding brake technology and is electrically controlled in both directions thus guaranteeing a particularly high level of personal safety. The passage area is monitored by a basic sensor system with a short design. It monitors the individual passages in both directions. This sensor system also monitors the swinging area and the blocking elements and acts as a protection device. In the event of a power failure, both directions may be freely accessed. Automatic reset upon resumption of power supply – the unit resets to its regular function without manual intervention.

4

-

-

... More
The access area is secured immediately upon resumption of power supply. The unit can be locked in any position (Tooth Holding Brake Technology) and opens under load (personal safety in case of panic). In basic position, the unit is unlocked to minimise power consumption. Parameters can be set for unit behaviour and each specific customer (e.g. starting behaviour and passage speed). (4) Standard measurements: Total width: 1,070 mm for normal and 1,320mm for wider, passage width: 650 N/900 W mm, interlock height: 945 mm & wings height 900 mm and total length 1660 mm (5) MCBF: Complete swing flap barrier unit/system MCBF (mean cycles between failures) is 10 million for 650 mm passage width and 8 million for 900 mm passage width (6) standby power consumption 17 VA DormaKaba Argus HSB- E07- Normal Lane & Wider lane (HSN Code No IS:84798999)

-

-

-

... More
Passenger lifts 1. Design, supply, installation, testing and commissioning of the passenger lifts as per technical specifications/drawings and as directed by Engineer In Charge. 2. Procurement of items with aesthetic value and visibility shall be on prior approval of Architect and Engineer in charge for specific area of application 3. Passenger lifts (1768kg) - (with Machine room and gear less) having contract speed of 1.50mps serving different floor in the lift shaft as per detailed specifications enclosed and as under: • Load: 1768kg • Capacity: 26 passengers • Speed: 1.50mps • Floor Marking: 7 (G to 6th Floor) • Travel: 29.4mtr • Stops & opening: 7stops/7 opens • Automatic rescue device complete as required • Operation: 3 Car group passenger lifts with DCS. FULL DOAS system with 2 key pads in GF and 2 key pads in all other floors with voice announcement and braille with disabled friendly feature. • Hoistway available: 2650mm W x 3000mm D • Car size: “Min. 1600mm W x 2400mm D x 2200mm H” • Type of doors a. Car Doors: SS Textured Panel with min 2 hrs fire rating (Scratch Proof) b. Landing doors: SS Brushed Finish .1000mm W x 2000mm H Center Opening.

12

-

-

... More
Lift Car Finishes: a. Side & Rear walls - SS Textured Panel (Scratch Proof) b. Ceiling - SS Brushed Finished Panel with protected LED light of indirect lighting with min.150 Lux at 1 meter above floor level. Rectangular grill in ceiling with Exhaust blower fans covering full length width with overhead ventilation grids for optimum air flow. Noise level of ventilation fan shall be limited with 35dB(A) at 1m distance c. Flooring - 25mm recess in platform with Granite finish (As per approval from Architect and Engineer in charge) 4. Kick plate shall be as per Panel Finish with 2-3 inch height. 5. Lift shaft reducing channels to be considered if required. 6. All Finishes shall be to resistant fingerprint marks from constant use for ease cleaning and maintenance. 7. Final finishing selection shall be as per instructions of Architect & Engineer's In-charge 8. Other parameters / requirements should be considered as per detailed specification sheet. 9. All elevators shall be. The regenerative power developed shall be utilised In the elevator system itself. % of energy saving shall be as per OEM design. Bidder to demonstrate the energy saving due to usage of regenerative drives during the commissioning of elevator. 10. Handrail not less than 1200mm long at 900mm above floor level to be fixed adjacent to control panel in lift car. 11. Voice announcement system in the car to announce the position of the lift in the hoist way as the car passes or stops at a floor served by the lift.

-

-

-

... More
Service /Passenger lift 1. Design, Supply, installation, testing and commissioning of the following lifts as per technical specifications/drawings and as directed by Engineer In Charge. 2. Procurement of items with aesthetic value and visibility shall be on prior approval of Architect and Engineer in charge for specific area of application 3. Service / Passenger lifts (1500kg) - (with Machine room and gear less) having contract speed of 1.5mps serving different floor in the lift shaft as per detailed specifications enclosed and as under: • Load: 1500kg • Speed: 1.5mps • Floor Marking: 8 (G to Terrace) • Travel: 33.6mtr • Stops & opening: 8 stops/8 opens • Automatic rescue device complete as required • Operation: Simplex • Hoist way available: 2750mm W x 2500mm D • Car size: “Min 1700mm W x 2000mm D x 2350mm H • Type of doors o Car Doors: SS Textured Panel with min 2 hrs fire rating (Scratch Proof) o Landing doors: SS Brushed Finish .1100mm W x 2000mm H Center Opening. • Lift Car Finishes: o Side & Rear walls - SS Textured Panel (Scratch Proof) o Ceiling - SS Brushed Finished Panel with protected LED light of indirect lighting with min.150 Lux at 1 meter above floor level. Rectangular grill in ceiling with Exhaust blower fans covering full length width with overhead ventilation grids for optimum air flow. Noise level of ventilation fan shall be limited with 35dB(A) at 1m distance o Flooring - 25mm recess in platform with Granite finish (As per approval from Architect and Engineer in charge)

2

-

-

... More
4. Kick plate shall be as per Panel Finish with 2-3 inch height. 5. Lift shaft reducing channels to be considered if required. 6. All Finishes shall be to resistant fingerprint marks from constant use for ease cleaning and maintenance. 7. Final finishing selection shall be as per instructions of Architect & Engineer's In-charge. 8. Other parameters / requirements should be considered as per detailed specification sheet. 9. All elevators shall be provided with regenerative drives. The regenerative power developed shall be utilised in the elevator system itself. % of energy saving shall be as per OEM design. Bidder to demonstrate the energy saving due to usage of regenerative drives during the commissioning of elevator. 10. Handrail not less than 1200mm long at 900mm above floor level to be fixed adjacent to control panel in lift car. 11. Voice announcement system in the car to announce the position of the lift in the hoist way as the car passes or stops at a floor served by the lift

-

-

-

... More
FIRE SAFETY ACCESSORIES & MISCELLANEOUS

-

-

-

... More
Supply, Providing & Fixing the following other miscellaneous items:

-

-

-

... More
Supply and Positioning fire buckets (4 # Fire Sand buckets with 1 # stand as per Electricity rules.)duly signed and fixed on an angle iron frame as per the requirements of local Electricity authorities. The fire buckets shall be painted red from outside and white from inside and shall be provided with extra handle at bottom.

1

-

-

... More
Supply & Fixing in position approved A1 size drawing display board with laminated drawings.

2

-

-

... More
Supply and positioning of Electrical 1.1kV Class-A approved tested quality Rubber mats of 1.8 m length, 0.9 m wide & 5mm thick, installed in front of the power distribution boards and DBs conforming to latest BIS.

5

-

-

... More
Supply & Fixing in position approved shock treatment chart written in English, Hindi & Local language. The chart shall be neatly laminated & suitable for displaying on to the fence.

1

-

-

... More
Providing of position the best quality danger boards of approved shape and size as specified by the local electrical authorities written in Hindi, English and local language.

4

-

-

... More
440V Enamelled Danger Board

4

-

-

... More
Electrical Single Line diagram (As Built drawing) with teakwood frame and glass cover and Soft copy of CD

1

-

-

... More
First Aid Box complete with all standard first aid materials

1

-

-

... More
Providing and Positioning the fire Extinguishers

-

-

-

... More
Supply, lnstallation, testing and Commissioning of Carbon Dioxide (CO2-6kG) type Fire Extinguisher conforming to IS:15683, with ISI marked approved fitted with required accessories including wall suspension brackets as per specification/drawings and as directed by Architect / Engineer in charge .

4

-

-

... More
Supply, lnstallation, testing and Commissioning of ABC Dry Chemical powder Mono-Ammonium Phosphate (MAP)-90% (stored pressure) type - 6 kg Fire Extinguisher conforming to IS:15683, with ISI marked approved fitted with required accessories including wall suspension brackets as per specification/drawings and as directed by Architect / Engineer in charge .

4

-

-

... More
Mobile foam unit of 50 lts. Capacity with water inlet and foam water out let, foam maker, foam branch pipe & hoses etc. complete. Unit shall be fabricated by M.S. sheet with FRP lining inside and whole unit mounted with rubber wheels of suitable size and handle for movements. Make: Gunnebo

2

-

-

... More
Statutory Sign Boards as per Approval requirement

2

-

-

... More
Hand operated fuel transfer pump with flexible hose PVC pipe of 10M length.

2

-

-

... More
LIAISON WORKS

-

-

-

... More
Vendor should coordinate and Obtaining clearance, license and safety certificates from State pollution control board, CEIG ,CCOE (if Applicable) and other local bodies, etc if any applicable for installation and operation of the 2x 2250 kVA DG SET.

1

-

-

... More
ADDRESSABLE FIRE ALARM SYSTEM

-

-

-

... More
Supply,Installation, Testing and Commissioning of Analogue Addressable Intelligent 10 loop Fire alarm control panel including loop card, provision to make with a minimum capacity of 125 devices + 125 modules per loop, with battery back up for 48 Hrs during normal operation and 15 minutes alarm operation, with minimum 160 Character LCD display, necessary interface card to connect a repeater panel,shall have provision for additional loops, each loop shall be 80% loaded, peer to peer networked fire alarm panels and all hardware & software as per specification. (UL and FM approved)

1

-

-

... More
Supply,Installation, Testing and Commissioning of of Bacnet card for BMS integration

1

-

-

... More
Supply,Installation, Testing and Commissioning ofof multi sensor detector (photo+heat) with base,powder coated back box and other accessories as required and Detectors shall be UL listed, -latest edition (ABOVE FALSE CEILING & FALSE FLOOR)UPS Room

16

-

-

... More
Supply of Propose detector to use 2 IR sensor and One UV sensor with different wave length and narrow-band filtering , Uv sensor to be with solar Blind band and a relay out put , The detector suppress the interference of sunlight, Lightning, Electric Welding, Thermal radiation , ElectroMagnetic Interference, Mechanical Vibration and other Interference i order to achieve rapid response of flame signal, These Signal are to be processed by the 32 bit processer and detection angle of 90 Deg for IR and 120 Deg For UV. the longest distance 50 Mtrs max, Design to be suitable for Hazardous area

1

-

-

... More
Supply,Installation, Testing and Commissioning of of Analog Addressable Smoke Detector with programmable for timed automatic sensitivity selection with Standard base and other accessories as required and Detectors shall be UL Listed-latest edition (ABOVE FALSE CEILING / TRUE CEILING)

1280

-

-

... More
Supply Installation of heat detector with base, Junction box and other accessories as required and Detectors shall be UL listed-latest edition ,

3

-

-

... More
Supply, installation, fixing, testing and commissioning of Addressable four-wire 70mtr coverage Beam smoke detector with Single-ended, reflective design, Six user selectable sensitivity levels, Optional integral NFPA 72 sensitivity test feature, Digital display for easy alignment, suitable for operating in temperature range of (-) 22°F to (+) 131°F (UL Listed).It should provided with necessary Power supply units, fixing accessories as required

8

-

-

... More
Supply,Installation, Testing and Commissioning of Analogue Addressable Fault isolator module capable of monitoring shorted loop circuit and automatically restore communications when shorted conditions are corrected. (FIM's are used for every 20 detectors/devices)

83.2

-

-

... More
Supply,Installation, Testing and Commissioning of Analogue Addressable Monitor module operating at 24V DC, 2A, rated at 230V, provided with DPDT contact. (FLOW SWITCH,BB INTEGRATION,PA INTEGRATION,WLD,SPARE) - UL & FM approved

43

-

-

... More
Supply,Installation, Testing and Commissioning of Analogue Addressable Control module operating at 24V DC, 2A, rated at 230V, provided with DPDT contact.(HOOTER) - UL & FM approved

28

-

-

... More
Supply,Installation, Testing and Commissioning of Analogue Addressable Control relay module operating at 24V DC, 2A, rated at 230V, provided with DPDT contact.(AC UNITS ) - UL & FM approved

58

-

-

... More
Supply,Installation, Testing and Commissioning of Addressable Electronic Hooter cum Strobe ceiling mounted. The hooters shall be made of ABS plastic, and have a DB level of85dbA and a multi tone facility. Addressable Control Module shall be fitted in a junction box.

129

-

-

... More
Supply,Installation, Testing and Commissioning of Addressable Manual call point having an integrally mounted addressable module that monitors and reports contact status. (PULL TYPE) UL listed

129

-

-

... More
Supply,Installation, Testing and Commissioning of 2C x 1.5 mm2, Stranded Copper conductor,Type A ST1 PVC insulated,Armoured FRLS CU Cable 650 V as per IS 1554, with GI saddle spacers every 0.3 mtr with Single compression Cable Glands,ABS Junction Boxes (wherever required), terminals,Ferruling complete.

26673

-

-

... More
Supplying, installing, testing and commissioning of approved make FRLS 25mm dia PVC conduits (heavy duty) on ceiling / wall / floor etc. complete with accessories like, Junction boxes, Collars, Bends, clamps, saddles etc. (for MCP)

645

-

-

... More
Supply and laying of MS Powder coated Trunking 300 x 50 mm x 1.2 mm with cover & fixing suppports etc as required (Cable dressing for Fire & PA panel )

112

-

-

... More
Supply and laying of GI enclosed raceway 300 x 50 mm x 1.2mm with cover & fixing suppports etc as required (Cable dressing in common passage between modules) )

105

-

-

... More
Supply,Installation, Testing and Commissioning of of PSU for hooters & AHU tripping (inclusive of Battery ckt & battery) UL listed

28

-

-

... More
PUBLIC ADDRESS SYSTEM

-

-

-

... More
Supply, installation, fixing, testing and commissioning of of 6W RMS True Ceiling Mount Speakers with inbuilt 100V Line Matching Transformer, wide opening angle, optimized for music & speech applications with powder coated back box, supports as per specifications Speakers shll have the tappings at 1.5/3/6 watts

1280

-

-

... More
Supply, installation, fixing, testing and commissioning of of 6 W Wall Mounted Speakers with line matching transformers as specified as per specifications

43

-

-

... More
Supply, installation, fixing, testing and commissioning of of EN-54 Certified IP based EVAC PA controller capable of adding 12 zones in the system and expandable upto 400 zones with 14x 4 Audio matrix with full DSP functionality. 8 audio inputs, 4 audio outputs, 4 channel output matrix. Shall support the following: single line switching or redundant group A/B switching, amplifier redundany, 4 x 100V audio inputs and 12 speaker line outputs. 8000 fault, warning and event conditions log. Built in message manager for 100 emergency/business calls up to 85 minutes. 10 control inputs and 13 control outputs. Impedance measurement and Pilot Tone supervision for speaker line monitoring. The controllers shall be able to exchange audio signals over the network without the need of a running PC/server, software dependent solutions shall not be accepted.The network controllers will be integrated using an interface module which is able to send and receive Dante audio to and from other Controllers.Frequency response (ref. 1 kHz) 20 Hz to 20 kHz (-0.5 dB), Signal-to-noise ratio (A-weighted): Line in to line out: 106 dB typical, THD+N 0.05%, Crosstalk (line level) Line in to line out (0 dB gain): 100 dB at 1 kHz, Sample rate 48 kHz, DSP processing resolution 24-bit linear A/D and D/A conversion, 48-bit processing. The omneo interface unit is able to send and receive Dante audio to and from other PA Controllers with the transmission of up to 16 digital audio input signals and 16 digital audio output channels with low latency shall be possible.Ethernet connectors (Primary /Secondary)100/1000 Mbit/s, RJ-45,integrated transformer isolationSampling rate 48 kHz. Data format 24 Bit. Audio channels Up to 16 ✕ 16 at 48 kHz, Audio flows Up to 16 ✕ 16 simultaneous audio streams,Latency across network 5 ms (typically) Bosch-PAVIRO/Ateis-IDA8/Honeywell-X618

1

-

-

... More
Supply, installation, fixing, testing and commissioning of of EN54 Certified EVAC Router for 24 zones to route 4 channels into 8 100V audio inputs to 24 loudspeaker line outputs. 2-in-6 matrix. 20 Control Inputs, 26 Control Outputs. Shall support single line switching or redundant group A/B switching, amplifier redundancy. Impedance measurement and Pilot Tone supervision for speaker line monitoring. Shall be able to handle up to 4000Watt load. Bosch-PAVIRO/Ateis-IDA8/Honeywell-X618

2

-

-

... More
SITC of EN-54 certified Call Station with extension keypad to serve minimum 12zones, Multilanguage LC display(122 ✕ 32) pixel , gooseneck microphone with supervised electret microphone, pop shield and permanent monitoring, integrated loudspeaker for system sounds. Five menu/function keys, 15 customizable function and speed dial buttons. Possible to use keys (push buttons) for Zone select, source select, level control, emergency on/off, message on/off, failure acknowledge/reset, Switching output trigger on/off or 0 to 10V, select scheduled events, scheduled event on/off. Call Station is completely supervised by system controller. Bosch-PAVIRO/Ateis-IDA8/Honeywell-X618

1

-

-

... More
Supply, installation, fixing, testing and commissioning of of EN-54 certified 2x 500W Class D, high efficiency amplifier. 70/100V loudspeaker output voltages, galvanically separated, 4 automatic selectable audio inputs on RJ45, local input. THD ≤1%. Frequency response, ref. 1 kHz, rated load, -3 dB : 50 Hz to 25 kHz. Signal-to-noise ratio (A-weighted) 104 dB, Output noise (A-weighted) -62 dBu, Crosstalk , ref. 1 kHz -85 dB. Audio input level limiter, RMS output power limiter, high temperature, DC, short circuit, mains undervoltage protection, DC supply undervoltage protection, inrush current limiter, ground fault Bosch-PAVIRO/Ateis-IDA8/Honeywell-X618

9

-

-

... More
2C x 1.5 mm2, Stranded Copper conductor,Type A ST1 PVC insulated,Armoured FRLS Cable 1100 V as per IS 1554, with GI saddle spacers every 0.3 mtr with Single compression Cable Glands,ABS Junction Boxes (wherever required), terminals,Ferruling complete.

7350

-

-

... More
Cable Tray

-

-

-

... More
Supplying and fixing of cable tray of size 300mm X 100mm

96

-

-

... More
SIGNAGE SYSTEM

-

-

-

... More
Supply, installation, fixing, testing and commissioning of " FIRE EXIT " (AUTO GLOW TYPE) - SINGLE SIDE - FOR FIRE EXIT DOORS - 150*300mm with suspension chains (SS)

42

-

-

... More
Supply, installation, fixing, testing and commissioning of "DIRECTIONAL EMERGENCY EXIT " (AUTOGLOW SIGNAGE) - DOUBLE SIDE

273

-

-

... More
Supply, installation, fixing, testing and commissioning of " EXTINGUISHER Signages - Autoglow, with suspension chains (Autoglo signages, size 150 x 300) - double side

342

-

-

... More
Supply, installation, fixing, testing and commissioning of " MCP Signages - Autoglow, with suspension chains (Autoglo signages, size 150 x 300 - double side

129

-

-

... More
Supply, installation, fixing, testing and commissioning of Fire Evacuation Route Map as per following specification Evacuation plan shall be glow in dark. A3 size with 5mm thick rear & 3mm thick front acrylic cover including wall mount supports.

28

-

-

... More
FIRE EXTINGUISHIERS

-

-

-

... More
Supply, installation, fixing, testing and commissioning of of CO2 type Fire Extinguisher ISI marked confirming to IS:15683 latest. Capacity 4.5 Kg. Complete with delivery hose horn, squeeze grip release valve, locking arrangement,operating temperature -30°C to +55°C, supplied with body bearing IS 7285 mark and approved by CCoE tested at 250 kgf/cm2., fitted with ISI marked & CCoE approved valve as per IS 3224. CO2 Gas as per IS: 15222. externally painted with PO Red Shade No. 538 of IS 5, operation manual and floor stand or Wall Mount Bracket including accessories as required as per site condition

18

-

-

... More
Supply, installation, fixing, testing and commissioning of of Powder Fire Extinguisher (Stored Pressure type) (Powder MAP 90 % pressurized with dry nitrogen gas at 15 bar.) capacity: 6kg duly ISI marked conforming to IS: 15683:2006/latest, with IS 14609 ISI marked ABC powder complete with squeeze grip release valve, discharge pipe, locking arrangement, pressure gauge, operation manual,Body Hydrotested at 35 bar, Operating temperature -30°C to +55°C, external epoxy powder coating with PO Red Shade No. 538 of IS 5, and floor stand or Wall Mount Bracket including accessories as required as per site condition

324

-

-

... More
Supply, installation, fixing, testing and commissioning of FE36 Automatic ceiling Mounted Clean agent Extinguisher - 10 Kg with Ceiling mount accessories including nozzle(57 deg), pressure guage. ISI approved - UPS (2),batttery(1), Server(2)

10

-

-

... More
FIRE PUMP ROOM

-

-

-

... More
Supply erection testing and commissioning of Electric Motor Driven Fire Pump set suitable for automatic operation and consisting of following: a. 1 No. horizontal end suction type fire pump capable of delivering 2280 LPM against a total head of 88 meters, so as to ensure a minimum pressure of 3.5 kg. per sq.cm at the farthest top most hydrant / outlet with pump casing of cast iron to grade FG 200, IS 210-1978 and parts like impeller, shaft sleeve, bearing ring etc., of non-corrosive metal either like bronze, brass or gun metal and shaft of stainless steel. b. 1 No. squirrel cage induction motor of required HP, 415 Volt, 3 phase 50Hz rating, conforming to IS:325-1978 with class "F" insulation, totally enclosed, IP 55 for enclosure fan cooled type conforming to relevant protection clause of IS 4691, synchronous speed of 2900 RPM. c. Common bed plate fabricated with MS channel / cast iron type for assembling the pump and motor flexible coupling between the pump and the motor with coupling guard for protection - 1 No. d. Making cement concrete foundation suitable for the above pump set including vibration isolation pads as necessary, foundation bolts, brackets, clamp fixtures, grouting, etc., in accordance with the manufacturer's design and as per standard methods and including conveying, fixing and incidental charges, etc., complete as per standard Specification.Note :The Pump head will be calculated based on the Hydraulic calculation.

2

-

-

... More
Supply, installation, testing and commissioning of Diesel engine driven pump set as per specification. The engine should have RPM between 1800 to 2150. The Pump shall be horizontal end suction, top discharge mounted on common base frame. Pump shall be directly coupled to diesel engine as per system design condition. Engine shall be complete with flywheel, spider coupling, Air cleaners, Water cooled, Heat Exchanger, Corrosion Resistor, Oil Sump with lube at pump. Governor, Fuel Filter, starting motor battery charging alternator & instrument panel suitable for 24 volt DC including starting switches, Diesel tank, lube oil temperature gauge, lube oil pressure & high water temperature including flexible exhaust connection. The pump shall be capable to delivery 2850LPM at 120MWC. Rate shall be inclusive of steel fabricated tank fitted with level indicator with stand, the tank should in elevated level than the Engine so that the fuel is drawn to the Engine due to gravity. Tank shall be designed to hold sufficient fuel oil for minimum eight hour operation.Note :The Pump head will be calculated based on the Hydraulic calculation.

2

-

-

... More
Supply, erection, testing and commissioning of 180 LPM, 88 meters Head Pressurization Pump Vertical Multistage with suitable HP electrical motor of Kirloskar make with suitable base frame including necessary vibration bad mounting etc., including conveying, fixing and incidental charges, etc., complete as per standard specification.Note :The Pump head will be calculated based on the Hydraulic calculation.

2

-

-

... More
Supply, erection, testing and commissioning of fire fighting application monoblock motor pump set of 900 LPM at 40 meters head to develop 3.5 kg/sq.cm at the heightest and farthest hydrant point to make 30 m water jet at the time of fire fighting emergency circumstances, coupled with 11 KW /15 HP rated three phase 414 volts, 50 Hz, 2880 rpm electrical motor the pump with cast ron body, bronze impeller, rope gland packaging, suction size of 80 mm dia. delivery size of 65 mm dia., including the cost of foundation concrete anti vibration mounting, rain safety hood and etc. complete as directed by the Departmental Officers (Kirloskarmake KDS 1555+ or Equivalent)Note :The Pump head will be calculated based on the Hydraulic calculation.

1

-

-

... More
Supply, erecting, testing and commissioning of Fire Fighting Electrical Control Panel of 15 HP, 415 V, 50 Hz Rating Wall Mounted Type fabricated using CRCA sheet, hinged lockable our, dust and vermin proof with following provisions: a. 63 Amps, 4 Pole MCB - Incomer, 6 Amps, 2 Pole MCB for Control Circuit - 1 set b. R, Y, B Phase Indication Lamp, Volt Meter (0 - 500 V),A meter (0 - 50 A), Volt Meter Selector Switch- 1 set c. 32 Amps Power Contactor with 230 V Coil, 14 - 23 Amps Over Load Relay - 1 set d. Single Phase Preventer - 1 No. e. Indication Lamp for Motor ON / OFF / TRIP - 1 set f. AUTO / MANUAL Selector Switch, ON / OFF Push Button - 1set g. Add On Block, Terminal Block, Power Wiring, Control Wiring, Connectors, Cable Lugs, Slotted Cable Cover The above panel mounted on wall using anchor fasteners bolts, plugs, incoming and outgoing cable connection and all works carried out as per standard methods and as directed by the Departmental Officers.

1

-

-

... More
FIRE FIGHTING PANEL (MCC PANEL FOR 1 curtain Pump 2no.s main electrical pumps & 2 Each. jockey pumps).IP 65 Design, Supply, Installation, testing and commissioning of cubicle type floor mounting switch board comprising of the following, the board shall be fabricated as per the detailed specification enclosed. The below mentioned ratings are indicative only however the contractor shall have to select the suitable rating breakers, switches, starters and related all the accessories based on the selected motors Incoming 630A, 36KA, 4P MOT MCCB with all connected accessories - 2 Each. as incomer. Incomers & Bus coupler shall have electrically interlocked with auto manual selector switch Instrument Panel Digital type MFM with RS485 port - 1 No Outgoing 200A TP&N 25kA THERMAL MAGNETIC MCCB with SOFT starter suitable for Electrical Driven Pumps with ON/OFF/TRIP indicating lamps, ON/OFF push buttons and all other required accessories - 3 Each 63A TP&N THERMAL MAGNETIC MCCB 25kA with SOFT starter suitable for Jockey pumps with ON/OFF/TRIP indicating lamps, ON/OFF push buttons and all other required accessories - 3 Each With necessary Aluminum bus bars, interconnections, earthling etc., with required accessories as per the specifications.630 Amps TPN Aluminum bus bars:- All the neutral bus bars shall have the same capacity of phase bus bars Also potential free contacts shall be provided for connecting to the IBMS Note : Incomer capacty to be validated based on selected Pump capacity

1

-

-

... More
DIESEL ENGINE AUTO START PANEL Supply installation testing and commissioning of Auto start panel for the diesel engine complete with auto/manual switch, relay, timers, contactors, rotary switches for AC ON / DC ON, indication lamps, protective fuses with battery charger, suitable of working on 230 V, AC, single phase, enclosure being vermin & dust proof, necessary alarms, different selector switches, push buttons etc. Also potential free contacts shall be provided for connecting to the IBMS. Battery charger with transformer with rectifier resistance DC ammeter, DC voltmeter, Trickle / booster / off selector switch - 2 Each.

2

-

-

... More
Supply and laying of 3 core 185 sq.mm.sizes of Armored Aluminum / Copper Cables for electrical motor, control panel, pressure switch, jockey motor etc., all incidental charges, necessary scaffolding and re-doing the dismantled portions to its original condition wherever found necessary, etc., complete as per standard specification and as directed by the Departmental Officers.

45

-

-

... More
Supply and laying of 4 core 10 sq.mm. armored copper cable for power wiring to the Terrace Pump Motor with runs of 14 SWG TC wire for earthling, providing in wall with suitable size GI clamps, screws, wooden plug, end termination by using suitable size cable glands, copper sockets and etc., as directed by the Departmental Officers.

15

-

-

... More
Supply and laying of 2 core 1.5 sq.mm. armored copper cable for control wiring to the Terrace Pump Motor with runs of 14 SWG TC wire for earthling, providing in wall with suitable size GI clamps, screws, wooden plug, end termination by using suitable size cable glands, copper sockets and etc., as directed by the Departmental Officers.

500

-

-

... More
Design, supply and laying of 50 x 6 mm GI. flat run along the cable tray

-

-

-

... More
Supply, erection of following sizes GI ladder type cable rack system made out of sheet steel folded to required shape with adequate number of supports. The rate shall be inclusive of suitable hanging support

-

-

-

... More
150mm x 75mm x 2.5mm

45

-

-

... More
300mm x 75mm x 2.5mm

20

-

-

... More
Supply and laying of suitable size electrical rubber mats tested to 11KV, with grooved ISI Mark. For pump room

3

-

-

... More
Supply and laying of 8 gauge bare copper wire for Gland earthling, loop earthling in the existing surface/recessed steel conduit, DB earthling and other equipment body earthling as required.

15

-

-

... More
Supply, erection, testing and commissioning of following sizes of Heavy Duty Foot Valve including all accessories, such as, MS flange of table ‘E’, gaskets, bolts & nuts, etc., installed at end of 150 / 200mm dia suction pipe line at sump including conveyance, all incidental charges, necessary scaffolding and re-doing the dismantled portions to its original condition wherever found necessary, etc., complete and as per standard specification and as directed by the Departmental Officers.

-

-

-

... More
100 mm dia

1

-

-

... More
Supplying, fixing, testing & commissioning of Double flanged Sluice valve of rating PN 16 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 14846 / IS 780 of following sizes as required : NOTE : Post Office Red / Fire Red paint shall be as per specification/drawings and as directed by PMC/Employer.

-

-

-

... More
250 mm dia

5

-

-

... More
200 mm dia

1

-

-

... More
150 mm dia

10

-

-

... More
65 mm dia

4

-

-

... More
Providing, installation, testing and commissioning of non-return valve of PN 16 rating of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required : NOTE: Post Office Red / Fire Red shall be as per specification/drawings and as directed by PMC/Employer

-

-

-

... More
200 mm dia

1

-

-

... More
150 mm dia

4

-

-

... More
65 mm dia

2

-

-

... More
Providing, installation, testing and commissioning of Stainless Steel body Y- strainer screen fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with Stainless Steel flange. NOTE: Post Office Red / Fire Red paint shall be as per specification/drawings and as directed by PMC/Employer

-

-

-

... More
150mm dia

1

-

-

... More
250 mm dia

2

-

-

... More
Supplying, fixing, testing and commissioning of Butterfly valve of PN 16 rating with C.I body , Cast Bronze or Stainless Steel disc, stainless steel shaft, Either integral or Nitrile rubber seat , Nitrite/ Silicon O-ring duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : NOTE: Post Office Red / Fire Red shall be as per specification/drawings and as directed by PMC/Employer

-

-

-

... More
200 mm dia

2

-

-

... More
150 mm dia

5

-

-

... More
65 mm dia - Lever Operated

-

-

-

... More
Supply, erection, testing and commissioning of suitable Pressure Switch of reputed make line Indfoss or Donfoss including necessary valves, couplings, etc., connected with electrical main control panel and setup at proper differential so as to auto start and auto stop the electrical motor, jockey motor including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., completed as per standard specification and as directed by the Departmental Officers.

11

-

-

... More
Supplying and fixing air vessel made of 250 mm dia ,8 mm thick MS sheet ,1200 mm in height with air release valve on top and flanged connection to raiser drain arrangement with 25mm dia gun metal wheel valve with rwquired acessorries, pressure gauge and painting with synthetic enamel paint of approved shade as required ,

13

-

-

... More
Supply and installation 150mm venture type flow meter with (flow range 946 - 3785 LPM)

1

-

-

... More
SS 100 mm dial pressure gauge 0-16 bar

15

-

-

... More
Supply, lnstallation, testing and Commissioning heavy duty floating flange EPDM rubber expansion joint with unit control (tie rod & gusset plate) as per manufacturers specifications of standard length complete with all accessories tested to a pressure not less than 15 Kg./sqcm including rubber gaskets, flanges, nuts, bolts & washers complete as required as per specification/drawings and as directed by PMC/Employer.

-

-

-

... More
150 NB

6

-

-

... More
65 NB.

4

-

-

... More
Supply, lnstallation, testing and Commissioning of UL Listed/FM Approved pilot operated Pressure relief valve - of Ductile Iron body,Brass trim,Buna-N Synthetic Rubber with Direct Acting - Precise Pressure Control,Drip Tight Closure,drain arrangement. It shall have adjustable setting in range suitable for operating range of the pump. The relief valve outlet shall be led back to the tank. All accessories nuts, bolts, washer, connector and pipe fittings etc. as per specification/drawings and as directed by PMC/Employer. NOTE: Post Office Red / Fire Red paint shall be as per specification/drawings and as directed by PMC/Employer

-

-

-

... More
150 NB

1

-

-

... More
Supply, lnstallation, testing and Commissioning of spring operated Pressure relief valve - of Ductile Iron body,Brass trim,Buna-N Synthetic Rubber with Direct Acting - Precise Pressure Control,Drip Tight Closure,drain arrangement. It shall have adjustable setting in range suitable for operating range of the pump. The relief valve outlet shall be led back to the tank. All accessories nuts, bolts, washer, connector and pipe fittings etc. as per specification/drawings and as directed by PMC/Employer. NOTE: Post Office Red / Fire Red paint shall be as per specification/drawings and as directed by PMC/Employer

-

-

-

3

-

-

... More
Supply, Installation, of Ultra sonic level indicator Range 0-10 Meter

2

-

-

... More
Supplying, installing, testing and commissioning of Gun metal chrome finished Ball valves with fittings of screwed end type.

-

-

-

3

-

-

5

-

-

... More
Supply, erection, testing and commissioning of following MS ‘C’ Class Heavy Duty Pipe as per IS 1239 to withstand a developing pressure of 10 kg. / sq.cm including necessary fittings like MS flange of table ‘E’, elbows, reducers, gaskets, bolt, nuts with washers & joints as per standard method of arc welding, including one coat metal primer and two coat Post Office Red painting including conveyance, all incidental charges, necessary scaffolding and re-doing the dismantled portions to its original condition wherever found necessary, etc., complete as per standard specification and as directed by the Departmental Officers.

-

-

-

... More
150 mm dia

42

-

-

... More
100 mm dia

12

-

-

... More
80 mm dia

12

-

-

... More
65 mm dia

24

-

-

... More
25 mm dia

60

-

-

... More
20 mm dia

12

-

-

... More
Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including welding, fittings like elbows, teed, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required.

-

-

-

... More
200 mm dia (wall thickness 6.3mm)

30

-

-

... More
250 mm dia (wall thickness 6.3mm)

20

-

-

... More
Providing, fixing pipe supports from columns / wall or suspenders from roof slab to suit various dia of pipes made out of GI / MS adjustable rods threaded for a sufficient length to adjust the height of support along with clamping arrangement for holding pipes of anchor fastening, arrangement design of hanger and should confirm with specification.

400

-

-

... More
EXTERNAL HYDRANT SYSTEM

-

-

-

... More
Supply, erection, testing and commissioning of Fire Fighting 4 Way Fire Brigade Inlet with necessary gun metal 63mm dia non return spring shutter arrangements, so that to control one way flow at the time of emergency water supply by fire and rescue service fire engine entry including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the Departmental Officers

2

-

-

... More
Supply, erection, testing and commissioning of Fire Brigade draw out with foot valve and neccessary fittings / supports complete as per standard specification.

1

-

-

... More
Supply and fixing of Fire fighting application oblique type stainless steel Hydrant Valve of size 63mm dia with oblique type instantaneous coupling with rotating wheel to open and close the valve including MS flange of table “E”, bolts & nuts with washer as per IS 5290 at ring main around the building and wet riser inside the building including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary etc complete as per standard specification and as directed by the Departmental Officers.

20

-

-

... More
Supply, and fixing in position of Fire Fighting Application Hose of 63mm dia of 15 meters length binded by copper wire with 63mm dia stainless steel male and female instantaneous fire fighting special coupling as per IS 901 as directed by the Departmental Officers. Near every hydrant points including conveyance, all incidental charges, necessary scaffolding and re-doing the dismantled portions to its original condition wherever found necessary etc complete as per standard specification and as directed by the Departmental Officers.

40

-

-

... More
Supply, and fixing in position of Fire Fighting Application 63mm dia stainless steel short length Branch Pipe with hexagonal type spray nozzle of 15mm (or) 20mm jet bore. Near every hydrant points including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the Departmental Officers. Make: OMEX / KARTAR / LIFE GUARD / SAFE GUARD / EQUIVALENT.

20

-

-

... More
Supply of Fire Fighting Application MS Hose Box to keep two number of hoses and 1 No. of branch pipe with nozzle having proper glass window type double door with universe open key, painted inside white and outside Post Office Red. Near every hydrant point including conveyance, all incidental charges, necessary scaffolding and re-doing the dismantled portions to its original condition wherever found necessary, etc., complete as per standard specification and as directed by the Departmental Officers.

20

-

-

... More
Supply, erection, testing and commissioning of following MS ‘C’ Class Heavy Duty Pipe as per IS 1239 part 1- 2004 including necessary fittings like MS flange of table ‘E’, elbows, reducers, gaskets, bolt, nuts with washers & joints as per standard method of arc welding, including one coat metal primer and two coat Post Office Red painting including conveyance, all incidental charges, necessary scaffolding and re-doing the dismantled portions to its original condition wherever found necessary, etc., complete as per standard specification and as directed by the Departmental Officers. Price shall be inclysive of wrapping coat 4 mm thickness at under ground laying and road crosssing,

-

-

-

... More
200 mm dia

938

-

-

... More
100 mm dia

12

-

-

... More
Supply, erection, testing and commissioning of stuctural steel for supports

-

-

-

... More
MS supports

300

-

-

... More
Supplying, fixing, testing and commissioning of Butterfly valve of PN 16 rating with C.I body , Cast Bronze or Stainless Steel disc, stainless steel shaft, Either integral or Nitrile rubber seat , Nitrite/ Silicon O-ring duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : NOTE: Post Office Red / Fire Red shall be as per specification/drawings and as directed by PMC/Employer

-

-

-

... More
200 mm dia

12

-

-

... More
INDOOR HYDRANT

-

-

-

... More
Supply, installation of Fire Fighting Application 180 degree swinging type, hose reel drum with 20mm dia braided thermoplastic hose of 30 meters long, so as to extend to necessary distance by self rolling spindle wheel including necessary 20mm dia ball valve and open and close spray nozzle, warm clip, etc., as per the standard pattern of any reputed make at every floor nearer to hydrant valve, including conveyance, all incidental charges, necessary scaffolding and re-doing the dismantled portions to its original condition wherever found necessary., etc., complete as per standard specification and as directed by the Departmental Officers.

78

-

-

... More
Supply and fixing of Fire fighting application oblique type stainless steel Hydrant Valve of size 63mm dia with oblique type instantaneous coupling with rotating wheel to open and close the valve including MS flange of table “E”, bolts & nuts with washer as per IS 5290 at ring main around the building and wet riser inside the building including conveyance, all incidental charges, necessary scaffolding and re-doing the dismantled portions to its original condition wherever found necessary etc complete as per standard specification and as directed by the Departmental Officers.

78

-

-

... More
Supply, and fixing in position of Fire Fighting Application Hose of 63mm dia of 15 meters length binded by copper wire with 63mm dia stainless steel male and female instantaneous fire fighting special coupling as per IS 901 as directed by the Departmental Officers. Near every hydrant points including conveyance, all incidental charges, necessary scaffolding and re-doing the dismantled portions to its original condition wherever found necessary etc complete as per standard specification and as directed by the Departmental Officers.

160

-

-

... More
Supply, and fixing in position of Fire Fighting Application 63mm dia stainless steel short length Branch Pipe with hexagonal type spray nozzle of 15mm (or) 20mm jet bore. Near every hydrant points including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the Departmental Officers. Make: OMEX / KARTAR / LIFE GUARD / SAFE GUARD / EQUIVALENT.

80

-

-

... More
Supply ,installation, testing and commissioning of 25mm diameter Forged Brass Air release valve PN-1.6 BODY - Forged brass 25 mm

10

-

-

... More
Supplying, installing, testing and commissioning of Gun metal chrome finished 25mm dia Ball valves with fittings of screwed end type.

10

-

-

... More
Supply, erection, testing and commissioning of following MS ‘C’ Class Heavy Duty Pipe as per IS 1239 to withstand a developing pressure of 10 kg. / sq.cm including necessary fittings like MS flange of table ‘E’, elbows, reducers, gaskets, bolt, nuts with washers & joints as per standard method of arc welding, including one coat metal primer and two coat Post Office Red painting including conveyance, all incidental charges, necessary scaffolding and re-doing the dismantled portions to its original condition wherever found necessary, etc., complete as per standard specification and as directed by the Departmental Officers.

-

-

-

... More
150 mm dia

320

-

-

... More
80 mm dia

160

-

-

... More
Supply, erection, testing and commissioning of stuctural steel for supports

-

-

-

... More
MS supports

400

-

-

... More
Supplying, fixing, testing and commissioning of Butterfly valve of PN 16 rating with C.I body , Cast Bronze or Stainless Steel disc, stainless steel shaft, Either integral or Nitrile rubber seat , Nitrite/ Silicon O-ring duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : NOTE: Post Office Red / Fire Red shall be as per specification/drawings and as directed by PMC/Employer

-

-

-

... More
150 mm dia

80

-

-

... More
Supply ,installation ,testing and commissioning of Fire Shutter as per approved sample

80

-

-

... More
SPRINKLER SYSTEM

-

-

-

... More
Supplying, installing,hydraulic testing and commissioning of Heavy grade MS Pipes confirming to IS :1239 part - I with malleable specials confirming to IS:1239 part - II, such as Tees, elbows, check nuts, unions, flanges, nipples etc. Including cutting, fixing in / on walls / on Floors, ceiling by using suitable supports such as MS channels ,angles,flats,rods as required at site with anchor fasteners,clamps,threaded rods,nuts,bolts,washers etc...complete. Painting the exposed with one coat of metal zinc chromate primer with two coats of synthetic enamel paint of approved colour / shade etc., complete.The pipe fittings shall be up to threaded 50 mm dia and Weldable type for 65 mm dia & above.

-

-

-

... More
25mm nominal dia

8748

-

-

... More
32mm nominal dia

2132

-

-

... More
40mm nominal dia

2067

-

-

... More
50mm nominal dia

1379

-

-

... More
65mm nominal dia

664

-

-

... More
80mm nominal dia

775

-

-

... More
100mm nominal dia

845

-

-

... More
150mm nominal dia

563

-

-

... More
Supply testing and commissioning of 15 mm gunmetal/chrome quartzoid bulb, standard response sprinkler heads suitable for 68 deg. C, K 80 (UL listed)

-

-

-

... More
Upright - 68deg C

4643

-

-

... More
Providing, fixing, testing & commissioning of Installation control valve of Cast Iron body, 17.5 kg/sq.m brass/bronze working parts comprising of water motor alarm, SS-304 clapper, clapper arm and hydraulically driven mechanical gong bell to sound continuous alarm when the wet riser/sprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box, ball valves, MS pipe of required size, flanges, orifice plate, gasket etc of following sizes as required : NOTE: Post Office Red / Fire Red color paint shall be as per specification/drawings and as directed by PMC/Employer 150 dia

-

-

-

... More
Dial type pressure guage for (0-16 Kg/cm2) with necessary nipple & other fittings, mounting arrangements and with a 15 mm ball valve

20

-

-

... More
Supply, Installation, Testing & Commissioning of 25mm Ball valve with sight glass for Sprinkler test line

28

-

-

... More
Supply, Installation, Testing & Commissioning of 50mm Ball valve for Sprinkler drain line

28

-

-

... More
Supply, Installation, Testing & Commissioning of Flow Switches with two NO and two NC contacts with necessary nipple & other fittings, Flow switch shall be suitable for 150 dia

28

-

-

... More
Supplying, fixing, testing and commissioning of Butterfly valve of PN 16 rating with C.I body , Cast Bronze or Stainless Steel disc, stainless steel shaft, Either integral or Nitrile rubber seat , Nitrite/ Silicon O-ring duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required and with Tamper Switch for Butterfly valves with BMS compatible of the following diameters complete with all necessary accessories, the tamper switch shall be provided with potential free contact with 2 nos. NO/NC as per specification/drawings and as directed by PMC/Employer.

-

-

-

... More
100mm dia

8

-

-

... More
150mm dia

22

-

-

... More
Supply & fixing of approved type rosette plates ( Recessed type, in two piece) for Sprinklers below false ceiling area.

-

-

-

... More
The Rosette shall be fabricated by M.S. plate of 2mm thick and the finish shall be powder coated and color shall be as approved by architects / clients.

100

-

-

... More
Stainless steel corrugated flexible pipe(hose) for dropping sprinklers below false ceiling, pipe shall be UL Listed, 16 bar pressure rating and 1800 mm long 25 mm dia with union / reducer collar, clamps etc. as required. (BRAIDED)

100

-

-

... More
Supply, erection, testing and commissioning of Air Release Valve with ball valve of 20mm dia, so as to release airlock in 150 mm dia MS pipe at top most wet riser, including conveyance, all incidental charges, necessary scaffolding and re-doing the dismantled portions to its original condition wherever found necessary, etc., complete as per standard specification and as directed by the PMC/Employer

4

-

-

... More
ACCESS CONTROL SYSTEM

-

-

-

... More
Supply, Installation, Testing and Commssioining of 2 reader controller, power supply unit, TCP IP connectivity with tamper detection provision as per the tender specifications.Cost shall inclusive of enclosure and power supply unit for controller/EM locks (power supply unit shall inclusive of battery backup 8 hrs). Controller Should Support global Antipass back.

11

-

-

... More
Supply, installation, testing & commissioning of Smart card readers with 2.5mm thick SS front plate as per specification suitable for mounting on metal surface/metal frames or wooden frames wall or as required based on site conditions including all accessories.

22

-

-

... More
Supply, installation, testing and commissioning of Smart Access Cards with Lanyard to hold the cards as per specification.

500

-

-

... More
Supply, Installation, Testing and Commssioining of Electromagnetic Lock with required mounting brackets for single door as per the tender specifications

6

-

-

... More
Supply, Installation, Testing and Commssioining of Electromagnetic Lock with required mounting brackets for double door as per the tender specifications

6

-

-

... More
Supply, Installation, Testing and Commssioining of surface / flush mounted (as required at site) Magnetic Contact (Door position sensor) for access controlled doors as per the tender specifications

18

-

-

... More
Supply,Installation, Testing and Commssioining of the Security Management Server software and also proivde Integrated Access Management 1 Master Software for Access Control & Time & attendance software with alarm monitoring as per the tender specifications Vendor shall consider as per OEM recommendations.

1

-

-

... More
Supply, Installation, Testing and Commssioining of security Management Software PC Server Station with minimum Intel i8 3.1 Ghz processor, 16 GB RAM, Graphics card with 1GB, 500 GB HDD, 24" Color flat panel LED Monitor,500TVL, 1080P HD Resolution, 100/1000Mbps network card with original Microsoft Windows 8 Operating System or higher, antivirus softwares,MS softwares.Vendor shall consider as per OEM recommendations These PC (1#) will be loaded with Security Management Server software Master Software, Access Control & Alarm Monitoring

1

-

-

... More
Supply and laying of 4 core 1.0 Sq mm Un Armoured Shielded, Multistanded Copper Conductor, PVC sheathed Cable with accessories for connecting controller to Lock & door position sensors, Buzzer,BGU,Pushbutton as per the tender specifications

1848

-

-

... More
Supply and laying of 8 core x 1 Sq mm Un Armoured Shielded, Multistanded Copper Conductor, PVC sheathed Cable with accessories for connecting controller to readers as per the tender specifications

1540

-

-

... More
Supply and laying of CAT6 UTP 23AWG solid Unarmoured POE cable Cable shall inclusive of connectors, patch chord and complete with crimping. The cable shall be considered with connectors on both th ends inclusive of necessary accessories

110

-

-

... More
Supply and laying of 1" - 2 mm thick FRLS - PVC Conduits,JB's in wall, columns, ceiling etc., including associated civil works

3498

-

-

... More
Supply, Installation, Testing and Commissioning of Buzzer for access controlled doors as specified in the Tender Specifications

12

-

-

... More
Supply installation, testing, commissioning of EDR (EMERGENCY BREAK GLASS )

12

-

-

... More
Supply and laying of MS Powder coated Trunking 300 x 50 mm x 2mm with cover & fixing suppports etc as required for panel dressing

33

-

-

... More
8 port 10/100/1000 layer 2 , LAN switches with IP multicast snooping and data-driven IGMP support and with minimum two 1000baseT RJ45 uplink ports and two 1000 baseT Fiber uplink ports, patch cords, patch panel and enclosure/rack for switch with mounting supports and all accessories.

10

-

-

... More
Supply, Installation, Testing and Commissioning of 3.5 Mtr straight arm with Reflective stickers and LED Strips wide Motorized Boom Barrier with LED on Front Door (for 4 wheelers) with required stiffeners on the Boom with Dual Eye Photo Sensors, which control electronics, IP 55 rated Housing for motor & electronics and a facility to connect long range readers, 100% duty cycle, the high speed of 4-5 secs door opening time & Not exceeding 2-3 seconds of closing time with mounting accessories etc., as specified in the Tender Specifications

4

-

-

... More
Supply, Installation, Testing and Commissioning of 1.5 Mtr straight arm with Reflective stickers and LED Strips wide Motorized Boom Barrier with LED on Front Door (for 2 wheelers) with required stiffeners on the Boom with Dual Eye Photo Sensors, which control electronics, IP 55 rated Housing for motor & electronics and a facility to connect long range readers, 100% duty cycle, the high speed of 4-5 secs door opening time & Not exceeding 2-3seconds of closing time with mounting accessories etc., as specified in the Tender Specifications

4

-

-

... More
Supplying, installation, testing and commissioning of X-Ray Single Generator Indoor Bagage Scanner with following technical parameters. Tunnel Size: Min 600 mm (W) x 400 mm (H) or Better, Dimensions: Length: Min 2000 mm or Better, Height: Max 1300 mm or Better. Single view of 160KV high energy XBS which provides steel penetration of 34mm Steel block and wire resolution of 38-AWG. 2 built-in Full HD cameras which helps to monitor the Tunnel Entry & Exit. Software with Inbuilt Artificial Intelligence tool that has 24 types of items to display the Scanned images with AI overlay. Single Screen that displays both Scanned images and video surveillance of Fisheye camera simultaneously. Complete with 0.5 meter Discharge SS Tables with dedicated computer for Monitoring, Image storage and archiving with necessary software. Along With Dual Core Processor at min 3.6 GHz, 8GB RAM, 4TB Harddisk, With Wired Mouse & Customised Keyboard with Emergency stop function, Linux OS and CMS to be incorporated for Centralised monitoring at the premises.

1

-

-

... More
Min 1 million images storage along with video recording of Full HD camera, Threat image protection (TIP) enabled in the software with 100 knives, 100 explosives, 100 guns to be loaded in the TIP library which enables the operator to active during security check. HIT, MISS & FALSE Alarm features must be included with different colour code as Green for HIT, Red for MISS and Yellow for FALSE alarm to be enabled in the software. Daily reports to be generated for TIP along with date, time, screener particulars and number of bags screened. Should comply with NABL, CE, FDA, ROHS, FCC, ISO, QCI, NSIC, BS EN 60204-1:2018, EN 61000-6-2-2005, EN 61000-6-3:2007, EN ISO 12100:2010

-

-

-

... More
Supplying, installation, testing and commissioning of Door frame metal detector (DFMD) with Dual side detection, 18 overlapping detector Multi-zones, Displaying panel, Indication of alarm areas, Adjustable area of sensitivity, Two Way operation, Static counting (Directional Counter - In, Out, Net and Alarm), Battery backup 6 to 8 hours. Shall be compatible to integrate with Barriers. Should comply with NABL, CE, FDA, ROHS, FCC, ISO, QCI, NSIC, BS EN 60204-1:2018, EN 61000-6-2-2005, EN 61000-6-3:2007, EN ISO 12100:2010

2

-

-

... More
IP CCTV SYSTEM

-

-

-

... More
IP based IR Dome Indoor Camera: Supply, Installation, Testing & Commissioning of  IP Network TDN, IR Dome Camera, 1/3" 2 MP CMOS , 2 MP @25fps or better , triple stream, Min. Illumination required 0.002ux/F1.5(color, 30IRE) 0Lux/F1.5(IR on), 120dB True WDR, Min. Pixels 1920 × 1080 (2 MP), 2.7mm~13.5mm, MFZ, motorized focus lens Backlight Compensation, Audio Input/Output, Alarm IN/OUT, 3DNR, Privacy Mask, 256GB SD Card support, IR Distance with upto 40m, with inbuilt analtycis Motion Detection, Video Tampering, Scene Changing, Tripwire Intrusion, Compression Technolgy H.265 / H.264 / Smart Codec / MJPEG, 128GB SD card support, IP67 , IK10+B1 , PoE, H.264, MJPEG, PoE IEEE 802.3af Class 0, 12 VDC,  Die-Cast Aluminium Construction, Having Operating temp range : –30°C to 60° C. Certifications: ONVIF Profile S, G, Q, T compliant, UL, CE, FCC,EN compliant. Required wall / ceiling mounting accessories as specified in the Tender Specifications . The camera shall be capable of operating on POE/12VDC/24VAC . The camera shall be certified with CE, FCC, UL and ROHS certifications. Camera shall be supplied along with Suitable adaptor with 3 meter cable and suitable mounting support/back box/MS powder coated pole for suspended cameras.

110

-

-

... More
Supplying, installation, testing and commissioning of IP Based Ultrakey Lite Control keyboard with function key, joystick, LED display, Dedicated Programmable keys for Operations

1

-

-

... More
Supply, Installation, Testing and Commissioning of 5MP IR PTZ Camera with built-in Wiper, Image Sensor:1/2.8" Progressive Scan CMOS, Min. Illumination: Color: 0.1Lux, BW: 0Lux (IR LED On), 30fps, Image Compression H.264 / H.265 / MJPEG or better, White Balance, Noise Reduction: 2D/3D DNR, Blur Detection: Yes, Shutter Speed: 2 - 1/12,000 sec or better, Day & Night: True Day/Night with ICR, Optical Zoom: 30X, Digital Zoom: 12X. Focus Mode: Auto / Manual, Focal Length: 5-150 mm IR Distance: 200 Meter or better built-in wiper, Optimized IR with adjustable intensity, and angle IR or better depending on the zoom ratio, Alarm Trigger: Alarm Input, Video Streams: Minimum 3 Nos, individually configurable streams in H.265@ 8MP resolution & 30 Fps, SD Card: Built in SD card slot with support up to 512GB or higher (inclusive of 1TB memory card), better Hi PoE supported, Working Temperature: -30°C ~ +55°C Protection Level: IP66, IK10, NEMA4X, NEMA-TS 2 (2.2.8, 2.2.9). IPv6, TCP/IP, UDP/IP, RTP(UDP), RTP(TCP), RTCP, RTSP, NTP, HTTP, HTTPS, SSL/TLS, DHCP, PPPoE, FTP, SMTP, ICMP, IGMP, SNMPv1/v2c/v3(MIB-2), ARP, DNS, DDNS, QoS, PIM-SM, UPnP, Bonjour, LLDP IP66, IK10; IP67, IK10, NEMA4X rated. The PTZ Camera shall be powered by POE also the cost shall inclusive of POE injector for required power to energies the PTZ Camera. Other technical detail shall be complied as per the technical specifications.

2

-

-

... More
IP based Bullet Camera: SITC of IP Bullet camera with 1/2.7" 2MP Progressive Scan CMOS, at 1920 x 1080 Resolution, 25 FPS, Triple streaming, min one H.264 stream & one H.264/MPEG 4 stream compression support, 2.8-12mm motorized lens, Color image at 0.01 lux, Tamper detection with built in True WDR of 120DB, BLC/HLC, True Day&Night with ICR, Auto Gain Control, 3D Noise Reduction, ONVIF profile S & G Support, Inbuilt Alarm mode for Network loss, Motion Detection. Required wall / ceiling mounting accessories as specified in the Tender Specifications . The camera shall be capable of operating on POE/12VDC/24VAC . The camera shall be certified with CE, FCC, UL and ROHS certifications. Camera shall be supplied along with Suitable adaptor with 3 meter cable and suitable mounting support/back box/pole/bracket. IP67, IK10 rating The camera shall be equipped with in built 32GB memory card and shall support upto 128GB SD Card which shall be used for recording during periods of server/ network failure.

24

-

-

... More
Mounting Pole: 7.0 Mtrs G.I. Octagonal Pole (70 mm A/F (Top) x 130 mm A/F (Bottom) x 5 mm thick with base plate of 250 x 250 x 16 mm, 4 nos. 600 mm long M20 foundation bolts & hardware (suitable reinforcements to be inserted in the foundation and 40mm x 2 nos. GI pipes for In/Out of main cables) Any other accessories etc. required complete in all respect as per direction of Engineer in charge. The pole shall also be provided with recessed lockable GI junction box of suitable size and flush door at the bottom with proper strengthening for the cutout of the door opening of junction box. Rate shall inclusive of RCC foundation with accessories etc. all complete.

12

-

-

... More
SITC of Network Video Recorder: Supply , Installation , Testing and commissioning of 64 Channel NVR (Network Video Recorder), Up to 32-ch IP cameras can be connected, Incoming Bandwidth 320 Mbps, , SATA Hard Disks with interfaces, ANR Technology, H.265/H.264/MPEG4 video compression, 3 × USB at least 1 × USB with 3.0, upport H.265, MJPEG,Supports RAID0, RAID1, RAID5, RAID6 and RAID10 ,Supports HDD hot swap, , Alarm I/O 16/4, RS-485, RS-232, 2 RJ-45 10 /100/1000 Mbps self-adaptive Ethernet interface, Multiple network monitoring: Web viewer, CE, FCC, UL certified, including fixing accessories and cable termination with required connectors/Jack, complete in all respect as per instruction of engineer in-charge. Storage to be considered at 720P, 15FPS, 60days Storage and 70% motion based recording . HDD Calculation to be submitted & should be approved by consultant. Rate shall be inclusive of required survveillance hard disk (make: Seagate, Western digital)

3

-

-

... More
Supply, Installation, Testing and Commssioining of Monitoing PC Station with the following specification Intel i8 3.4 Ghz processor, 16GB RAM Graphics card with 2GB, 1000 GB HDD, Dual HDMI Output, 4USB ports, 100/1000Mbps network card with original Microsoft Windows 10 Operating System, antivirus softwares,MS softwares,Wire less Keyboard & Mouse etc.or If the above specification is not match the vendor requirement. request vendor to consider as per OEM recommendation

1

-

-

... More
Supply, Installation, Testing & Commissioning of Main Viewing Screens with wall mount 4 x42" 4K UHD LED Screens, with HDMI/VGA outputs, PC inputs. Screens should have 2 ms or better response time, Energy Star compliant & capable to operate for 24x7 operation. It shall come with remote control and shall have various picture mode options for data representation with all necessary fixing accessiories for viewing. Note: The display shall be mounted 3 x 2 matrix and all four screen to be considered as single display screen / monitor. One input from Server / Client / CCTV Client PC shall be interfaced with Monitor Station. All necessary display controller, Encoder, Decoder, Splitter and Display configuration software etc., shall be considered to complete the successful installation of Video Display. Bidders shall be considered the necessary additional equipment cost in this line item. No additional cost shall be provided if will require to comply the above requirement.

1

-

-

... More
SITC OF RACKS for CCTV Equipments as per following specification, Conforms to DIN 41494 Or Equivalent EIA/ISO/EN/CEA Standard Finish - Powder coated finish with Seven tank pretreatment process meeting ASTM standard Color - Black/off white/grey Fan module Mount Provision on top Cover Welded frame with vented top cover with fan mounting provision, Associated Front Glass or perforated Metal Door with lock & Key and Back vented / Perforated metal door with lock & key and partially vented side panels, free standing on floor with 4 No. casters wheels with 2 no with brakes & 2 No. without brakes, cable oraginesers, Levelers with required 16A/5A power strips including accessories. Number of racks shall be as per the design requirement for switches locations and main cctv equipents. vendor to consider required number of racks as per their requirement

1

-

-

... More
POE SWITCHES, CABLING, CABLE TRAY and CONDUITS

-

-

-

... More
8 Port PoE+ Edge / Distribution Switch: Supply, installation, testing and commissioning of Edge Switch shall have minimum 8 *100/1000 RJ45 PoE+ ports and 4 x 1/10G SFP ports with redundant power supply. Minimum required PoE budget (8Port * 30W = 240) 240 Watts. Note: Bidder shall refer the Technical Tender Specifications for details for product compliance accordingly two 1000 baseT Fiber uplink ports, patch cords, patch panel and enclosure/rack for switch with mounting supports and all accessories.

14

-

-

... More
24 Port PoE+ Edge / Distribution Switch:Managaed Supply, installation, testing and commissioning of Edge Switch shall have minimum 24 *100/1000 RJ45 PoE+ ports and 4 x 1/10G SFP ports with redundant power supply. Minimum required PoE budget (24Port * 30W = 720) 720 Watts.

10

-

-

... More
Supply, installation, testing and commissioning of 24 Port SFP+ 2 Port ethernet - Managaed

2

-

-

... More
Supply, installation, testing and commissioning of Fiber otic cable Multimode Sinlgle Fiber

1500

-

-

... More
Supply and laying of CAT6 UTP 23AWG solid Unarmoured POE cable Cable shall inclusive of connectors, patch chord and complete with crimping. The cable shall be considered with connectors on both th ends inclusive of necessary accessories

8450

-

-

... More
Supply and laying of 1" - 2 mm thick FRLS - PVC Conduits,JB's in wall, columns, ceiling etc., including associated civil works

6760

-

-

... More
TALKBACK SYSTEM

-

-

-

... More
Supplying, installing, testing and commissioning of 50 zone selector P.A. console and with CRCA sheet housing and control desk( rack) as required. Console shall have all call / call back facility complete with battery back up and it should also work on AC single phase power.

1

-

-

... More
Supplying, installing, testing and commissioning solid state Amplifier of 160W RMS out put in rack, including necessory control wires, jocks etc. complete.

1

-

-

... More
Supplying, installing, testing and commissioning 6W wall mounted type speakers with talk back facility, in CRCA sheet fabricated housing, complete.

60

-

-

... More
4C X 1.5 Sq mm2, Stranded Copper conductor,Type A ST1 PVC insulated,Armoured FRLS with Single compression Cable Glands,ABS Junction Boxes (wherever required), terminals,Ferruling complete.

3450

-

-

-

-

-

... More
Design, Engineering, Supply, Inspection, testing, erection and commissioning of following items including water and air balancing.

-

-

-

... More
CHILLERS -Design, Supply, delivery, hoisting, including the customs clearance, freight up to site, Insurance, port handling charges, other local duties, loading, transportation, receving at site, unloading, positioning the chiller as per approved shop drawing, installation including supplying & installing all necessary accessories as required for complete and satisfactory operation, testing & commissioning for the following items as shown on the equipment data and drawing for complete and satisfactory operation. Specification to be complied by the vendor to met the performance of chiller as per tender conditions. First chiller shall be factory tested at design conditions at 100%, 75%, 50% and 25% load. (Charges for arranging inspection of chillers for 5 persons, at Manufacturer’s point for witnessing testing the chiller ( 1no. chiller ) at minimum 4 test points .. Clearly indicate the facilities available at manufacturer’s point for testing and also confirm wehther test bed is AHRI approved) All necessary hardwares / software's to integrate the chiller panel to BAS system shall be provided free of cost by chiller manufacturer / supplier. Control panel should be with open protocol like Modbus RTU/ Bacnet/ Lon work for integrating with BAS. Chiller is accepted only based on 100% loading and its performance shall be tested at site against approved data sheet. Any fall back on the performance to be corrected and rechecked and then chiller will be accepted.

-

-

-

... More
WATER COOLED CHILLERS -Supply, Installations, testing, erection and commissioning of WATER COOLED multiple screw compressors SCREW CHILLERS with BMS compatible VFD (Unit mounted factory calibrated. VFD shall be with active harmonic filter with THD not exceeding 5%.VFD shall be liquid cooled only, water/refrigerant cooled as per OEM standard.), IE4 motor, water cooled condenser, insulated chiller, flow switch at chiller and condenser, spring vibration isolators, integral refrigerant piping and wiring, grooved couplings at chilled & condenser water inlets & outlets, marine water box at condenser with hinges, accessories as required and called for, automatic and safety controls mounted in central console panel and all mounted on a steel frame etc. Motor shall be suitable for operating on 415±10% 50 cycles. 3 phase AC supply and soft starter. Refrigerant used shall be Ozone friendly HFC R134a as per specifications. Chiller for air conditioning system shall be selected on the design basis as given below condition. The chiller Microprocessor shall be suitable for BMS integration and provided with suitable protocal. Chillers capacity of each chilling unit will be as follows: Rate shall inclusive of factory witness test as specified in the technical specification. Chiller: Capacity -375TR (2 Working + 1 Stand-by) Chilled Water IN - 54°F . Chilled Water Out - 44°F Chilled Water Flow - 900 USGPM or as required Fouling factor - 0.0001 FPS, Condenser: Condenser Water IN - 87.98 °F, Condenser Water OUT - 96.26 °F Condenser Water Flow - 1313 USGPM or as required Fouling factor - 0.00025 FPS Maximum Power Consumed at above conditions : Not more than 0.63 kW/ TR Minimum IPLV: 0.37 Min COP at AHRI conditions : 6.5 or above

3

-

-

... More
VFD shall be unit mounted and factory fitted. Chiller shall be with factory fitted and unit mounted active harmonic filter with THD of less than 5% or less at all loads. Filter shall be IEEE 519 compliant. THDi should be displayed at the Chiller panel.

-

-

-

... More
Chiller ATC – Supply testing and commissioning of automatic tube cleaning system (ATCS) for 3 No’s chiller (1:1) shall include touch screen graphic PLC, one injection / collection pump, actuator based value shall give single to PLC of their functioning and all process of injection and collection should be shown on the PLC while in operation. The ATCS system can be individual to each chiller or may handle multiple chillers at a time .As per specification drawing and specified drawing and as directed by PMC/Client

-

-

-

... More
AIR COOLED CHILLER - Design, Supply, installation, testing and commissioning of Air COOLED SCREW CHILLER . - multiple screw compressors, energy efficient IE4 motor, Air cooled condenser, flow switch at chiller , spring vibration isolators, integral refrigerant piping and wiring, grooved couplings at chilled water inlets & outlets, accessories as required and called for, automatic and safety controls mounted in central console panel and all mounted on a steel frame etc. Motor shall be suitable for operating on 415±10% 50 cycles. 3 phase AC supply. Refrigerant used shall be Ozone friendly HFC R134a as per specifications. Chiller for air conditioning system shall be selected on the design basis as given below condition. The chiller Microprocessor shall be suitable for BMS integration and provided with suitable protocal. Chillers capacity of each chilling unit will be as follows: Rate shall inclusive of factory witness test as specified in the technical specification. Chiller Capacity : 375 TR at Design Condition ( +/- 2% on capacity) - (2 Working) Chiller Performance: 1.3 kW/TR FL and 1.1 kW/TR IPLV (max) at Design condition Chiller Side: Chiller Water in : 54 Deg F & Chiller Water out: 44 Deg F Ambient air temp 104 deg F Water Flow rate : 900 GPM Fouling factor : 0.0001 hr.sqft.degF/BTU Min COP at AHRI condition: 3.2 or above

2

-

-

... More
VFD shall be unit mounted and factory fitted. Chiller shall be with factory fitted and unit mounted active harmonic filter with THD of less than 5% or less at all loads. Filter shall be IEEE 519 compliant. THDi should be displayed at the Chiller panel.

-

-

-

... More
AIR COOLED CHILLER - Design, Supply, installation, testing and commissioning of Air COOLED SCREW CHILLER . - multiple screw compressors, energy efficient IE4 motor, Air cooled condenser, flow switch at chiller , spring vibration isolators, integral refrigerant piping and wiring, grooved couplings at chilled water inlets & outlets, accessories as required and called for, automatic and safety controls mounted in central console panel and all mounted on a steel frame etc. Motor shall be suitable for operating on 415±10% 50 cycles. 3 phase AC supply. Refrigerant used shall be Ozone friendly HFC R134a as per specifications. Chiller for air conditioning system shall be selected on the design basis as given below condition. The chiller Microprocessor shall be suitable for BMS integration and provided with suitable protocal. Chillers capacity of each chilling unit will be as follows: Rate shall inclusive of factory witness test as specified in the technical specification. Chiller Capacity : 150 TR at Design Condition ( +/- 2% on capacity) - (1 Working + 1 Stand-by) - Ciritical area Chiller Performance: 1.3 kW/TR FL and 1.1 kW/TR IPLV (max) at Design condition Chiller Side: Chiller Water in : 54 Deg F & Chiller Water out: 44 Deg F Ambient air temp 104 deg F Water Flow rate : 360 GPM Fouling factor : 0.0001 hr.sqft.degF/BTU Min COP at AHRI condition: 3.2 or above

2

-

-

... More
VFD shall be unit mounted and factory fitted. Chiller shall be with factory fitted and unit mounted active harmonic filter with THD of less than 5% or less at all loads. Filter shall be IEEE 519 compliant. THDi should be displayed at the Chiller panel.

-

-

-

... More
COOLING TOWER

-

-

-

... More
Design, Supply, installation, testing and commissioning of COOLING TOWER with BMS compatible VFD, Cross Flow or Counterflow, Induced Draft, Vertical Discharge Type, Twin Cell, FRP Cooling Tower complete with multiple motor, fan, film type Fill, other complete accessories as described in the technical specifications. It shall be designed with high efficiency drift eliminator. Vibration Isolators of spring open type designed to minimize any vibration from transmitting to other structures to be included in the scope of supply. Motors shall be suitable for 415 + 10%volt, 50 cycles 3phase power supply and IE4 efficiency type. The power Isolators (lockable type) at cooling tower enclosed in weather proof panel and required length of power cable from the starter panel to the equipment shall also be included. Cooling Tower for air conditioning system shall be selected on the basis of monsoon ambient condition. The heat rejection capacity of the cooling tower must be 1.25 times greater than the chiller capacity. The tower shall be CTI certified. Chiller Capacity : 450TR- (Cooling tower Capacity shall be in HRT) Water Flow Rate : 1313 USGPM Water Temp In & Out : 96.26 °F, & 87.98 °F Design wet bulb : 81 degF Approach : 7.0 Deg F

3

-

-

... More
Chiller Plant Manager (CPM)

-

-

-

... More
Design, Supply, installation, testing and commissioning of Chiller Plant Manager (CPM) for the proposed chiller plant. The chiller plant includes Air cooled Screw chillers , chilled water pumps , motorised valves on both chilled water inlet and outlets, etc. All the field equipments like temperature sensor, pressure sensor, flow switch, level switch, etc and required length of communication cable shall be included in the quoted rate. The detailed I/O summary is attached for the requirements of CPM The rate shall also be inclusive of Integrator for transferring the data available on the Chiller Plant Manager (CPM) to HVAC automation (BAS) system and third party BMS for remote monitoring & operation. All the parameters available on the CPM should be transferred to the BAS System. It shall be possible to monitor and control the system and to alter the Set Point / Vary / switch ON / OFF / Scheduling of equipment as minimum parameters to BAS System

1

-

-

... More
CENTRIFUGAL VERTICAL INLINE PUMPS

-

-

-

... More
PRIMARY PUMPS FOR CHILLER- Supply, erection, testing and commissioning of Single stage centrifugal coupled type INLINE pumpset with axial suction port and discharge port (with Bacnet MS/TP communication protocol), bronze impeller & mechanical seal. The noise level shall be limited to 70 dBA at a distance of 1.5 m, Minimum pump efficieicy should not be less than 85%, Motor efficieny not less than 90% (IE-4). Suitable HP,motor shall be TEFC squirrel cage type motors with IP55 protection. The Coupling shall be rigid spacer type of high tensile aluminum alloy. Couplings shall be split to allow removal from pump and motor shafts, leaving space between the shafts sufficient to replace all mechanical seal components without disturbing the pump or motor.The duty point of the pump shall be defined in the pump curve. (Insulation for chilled water pumps to be 32mm nitrile rubber of minimum density 36kg/m3, thermal conductivity of 0.032W/mK at 25 Deg C, covered with 500 GSM two layer vapour barrier and covered with 26 G Aluminium cladding). Pump design parameter / motor rating furnished in the BOQ is of indicative in nature. If the actual parameter required to meet the proposed HVAC system, then the same shall be provided by HVAC Contractor based on the final pump/motor selection without any cost implication to the Owner. Constant flow primary pump: 900 GPM to be delivered @ 25M head

5

-

-

... More
SECONDARY PUMPS FOR CHILLER: Supply, erection, testing and commissioning of Single stage centrifugal coupled type INLINE pumpset with axial suction port and discharge port with integrated variable speed drive motor(pump mounted) (with Bacnet MS/TP communication protocol), bronze impeller & mechanical seal. The noise level shall be limited to 70 dBA at a distance of 1.5 m, Minimum pump efficieicy should not be less than 85%, Motor efficieny not less than 90% (IE-4). Suitable HP,motor shall be TEFC squirrel cage type motors with IP55 protection. VFD - The variable frequency drive(s) shall be pulse width modulation (PWM) type, microprocessor controlled design.VFD shall be capable of operating in voltage ranges of 380 to 415 V +/- 10% AC, three phase; at frequencies of 48 to 63 Hz. VFD shall be factory fitted and unit mounted. The control should be a low harmonic control with a built-in DC link reactor equivalent in performance to a 5% AC line reactor.VFDs shall comply with IEC 61800-3 & have THD less than 5%. Active / passive filters must be use toachieve desired THD levels which will be in scope of Drive authorized supplier of OEM as per list of approved make. IEEE - 519 - 2014 standard is to be followed for harmonic control. VFDs shall be motor mounted and IP 54 rated.The Coupling shall be rigid spacer type of high tensile aluminum alloy. Couplings shall be split to allow removal from pump and motor shafts, leaving space between the shafts sufficient to replace all mechanical seal components without disturbing the pump or motor.The duty point of the pump shall be defined in the pump curve. The pump selected for variable speed drive shall be capable of performing satisfactorily over a wide range of speed, allowing a speed variation from 30 % to 100 %. The pump matrix also to be filled up for all vendors.(Insulation for chilled water pumps to be 32mm nitrile rubber of minimum density 36kg/m3, thermal conductivity of 0.032W/mK at 25 Deg C, covered with 500 GSM two layer vapour barrier and covered with 26 G Aluminium cladding). Pump design parameter / motor rating furnished in the BOQ is of indicative in nature. If the actual parameter required to meet the proposed HVAC system, then the same shall be provided by HVAC Contractor based on the final pump/motor selection without any cost implication to the Owner. Variable flow Secondary pump: 900 GPM to be delivered @ 50 M head

5

-

-

... More
CONDENSER PUMPS with BMS compatible VFD - Supply, erection, testing and commissioning of Single stage centrifugal coupled type INLINE pumpset with axial suction port and discharge port (with Bacnet MS/TP communication protocol), bronze impeller & mechanical seal. The noise level shall be limited to 70 dBA at a distance of 1.5 m, Minimum pump efficieicy should not be less than 85%, Motor efficieny not less than 90% (IE-4). Suitable HP,motor shall be TEFC squirrel cage type motors with IP55 protection. The Coupling shall be rigid spacer type of high tensile aluminum alloy. Couplings shall be split to allow removal from pump and motor shafts, leaving space between the shafts sufficient to replace all mechanical seal components without disturbing the pump or motor.The duty point of the pump shall be defined in the pump curve. (Insulation for chilled water pumps to be 32mm nitrile rubber of minimum density 36kg/m3, thermal conductivity of 0.032W/mK at 25 Deg C, covered with 500 GSM two layer vapour barrier and covered with 26 G Aluminium cladding). .VFDs shall comply with IEC 61800-3 & have THD less than 5%. Active / passive filters must be use toachieve desired THD levels which will be in scope of Drive authorized supplier of OEM as per list of approved make. IEEE - 519 - 2014 standard is to be followed for harmonic control. Pump design parameter / motor rating furnished in the BOQ is of indicative in nature. If the actual parameter required to meet the proposed HVAC system, then the same shall be provided by HVAC Contractor based on the final pump/motor selection without any cost implication to the Owner. Condenser flow pump: 2100 GPM to be delivered @ 20 M head

3

-

-

... More
Design, Supply, installation, testing and commissioning of chilled water Pump Starter Panel cum Logic controller panel with all necessary power & control circuit breakers, contactors, SPPR, auto/manual selector switches, earthing and internal power & control cabling, terminations with necessary lugs and glands, etc. , Microprocessor based logic controller, integrated Software capable to control frequency based on the inputs from sensors, 4 Nos of differential pressure sensor & transmitters, power cable from panel to pump, ON/OFF push button, communication cable, Communication card (BACnet protocol) to transfer the entire data available on unit mounted VFD ( 5 in Secondary pumps/ 3 in condensor pumps) to the third party BMS System.

1

-

-

... More
PRIMARY PUMPS - Supply, erection, testing and commissioning of Single stage centrifugal coupled type INLINE pumpset with axial suction port and discharge port (with Bacnet MS/TP communication protocol), bronze impeller & mechanical seal. The noise level shall be limited to 70 dBA at a distance of 1.5 m, Minimum pump efficieicy should not be less than 85%, Motor efficieny not less than 90% (IE-4). Suitable HP,motor shall be TEFC squirrel cage type motors with IP55 protection. The Coupling shall be rigid spacer type of high tensile aluminum alloy. Couplings shall be split to allow removal from pump and motor shafts, leaving space between the shafts sufficient to replace all mechanical seal components without disturbing the pump or motor.The duty point of the pump shall be defined in the pump curve. (Insulation for chilled water pumps to be 32mm nitrile rubber of minimum density 36kg/m3, thermal conductivity of 0.032W/mK at 25 Deg C, covered with 500 GSM two layer vapour barrier and covered with 26 G Aluminium cladding). Pump design parameter / motor rating furnished in the BOQ is of indicative in nature. If the actual parameter required to meet the proposed HVAC system, then the same shall be provided by HVAC Contractor based on the final pump/motor selection without any cost implication to the Owner. Constant flow primary pump: 360 GPM to be delivered @ 15M head

2

-

-

... More
SECONDARY PUMPS: Supply, erection, testing and commissioning of Single stage centrifugal coupled type INLINE pumpset with axial suction port and discharge port with integrated variable speed drive motor(pump mounted) (with Bacnet MS/TP communication protocol), bronze impeller & mechanical seal. The noise level shall be limited to 70 dBA at a distance of 1.5 m, Minimum pump efficieicy should not be less than 85%, Motor efficieny not less than 90% (IE-3). Suitable HP,motor shall be TEFC squirrel cage type motors with IP55 protection. VFD - The variable frequency drive(s) shall be pulse width modulation (PWM) type, microprocessor controlled design.VFD shall be capable of operating in voltage ranges of 380 to 415 V +/- 10% AC, three phase; at frequencies of 48 to 63 Hz. VFD shall be factory fitted and unit mounted. The control should be a low harmonic control with a built-in DC link reactor equivalent in performance to a 5% AC line reactor. VFDs shall be motor mounted and IP 66 rated .VFDs shall comply with IEC 61800-3 & have THD less than 5%. Active / passive filters must be use toachieve desired THD levels which will be in scope of Drive authorized supplier of OEM as per list of approved make. IEEE - 519 - 2014 standard is to be followed for harmonic control..The Coupling shall be rigid spacer type of high tensile aluminum alloy. Couplings shall be split to allow removal from pump and motor shafts, leaving space between the shafts sufficient to replace all mechanical seal components without disturbing the pump or motor.The duty point of the pump shall be defined in the pump curve. The pump selected for variable speed drive shall be capable of performing satisfactorily over a wide range of speed, allowing a speed variation from 30 % to 100 %. The pump matrix also to be filled up for all vendors.(Insulation for chilled water pumps to be 32mm nitrile rubber of minimum density 36kg/m3, thermal conductivity of 0.032W/mK at 25 Deg C, covered with 500 GSM two layer vapour barrier and covered with 26 G Aluminium cladding). Pump design parameter / motor rating furnished in the BOQ is of indicative in nature. If the actual parameter required to meet the proposed HVAC system, then the same shall be provided by HVAC Contractor based on the final pump/motor selection without any cost implication to the Owner. Variable flow Secondary pump: 360 GPM to be delivered @ 25M head

2

-

-

... More
Design, Supply, installation, testing and commissioning of air cooled chilled water Pump Starter Panel cum Logic controller panel with all necessary power & control circuit breakers, contactors, SPPR, auto/manual selector switches, earthing and internal power & control cabling, terminations with necessary lugs and glands, etc. , Microprocessor based logic controller, integrated Software capable to control frequency based on the inputs from sensors, 4 Nos of differential pressure sensor & transmitters, power cable from panel to pump, ON/OFF push button, communication cable, Communication card (BACnet protocol) to transfer the entire data available on unit mounted VFD (2 in Secondary pumps) to the third party BMS System.

1

-

-

... More
FLOOR MOUNTED AIR HANDLING UNITS:

-

-

-

... More
Supply, installation testing & commissioning EUROVENT CERTIFIED Horizontal / vertical floor mount Airhandling units having following specifications. Frame Structure consisting of 45mm Extruded Aluminium Thermal break profile Panel: 45mm +/- 2mm thick double skin sandwich panels with Puff insulation of density 48 kg/cum , The sheet thickness shall be minimum 0.8 mm for the outer skin and 0.8 mm thickness for the inner skin of GI . Filtration Section shall be provided with 2 stage washable type of 'MERV8 ' first stage and 'MERV13' final stage. Coil Section: Chilled water coil Minimum 6 row deep constructed with Aluminium fins of minimum 0.11mm thickness and copper tubes of minimum 29Guage thickness. Copper tube shall be 9.6mm or 12.5mm diameter. The coil face area shall not exceed 2.5m/sec. Coil shal be provided with copper header. Inbuilt UV Lamp to be considered upstream or downstream of the coil based on OEM recommendation with necessary interlock with the AHU whenver the AHU is shutoff, UV lamp shall be off and vice versa. Drain Pan: Condensate drain pan shall be fabricated from 20 G SS 304 powder coated, insulated with 19 mm thick closed cell elastomeric insulation. Fan Section: Direct drive backward curved EC fan ( Electronically commutated ) with permanent magnet brushless DC motor for stepless variation of speed of fan based on temperature sensor inputs. The fan section shall be provided with limt switch for safety to shut off fan during Opening of access door.

-

-

-

... More
AHU mounted graphical display with starter Panel with Auto /Manual switch and incomer power terminal. all internal cablings between panel and motor/ door interlocks / marine lamp etc should be considered Instrumentation Kit to be provided to give out the following option 1. Supply air temperature 2. Return air temperature 3. Chilled water in temperature 4. Chilled water out temperatue 5. DP switch across filter for fitler clog Controller module with RS 485 port compatible with BMS, on board protocol with touch screen to display following 1. EC fan operation status 2. Chilled water valve operation status 3. AHU Airflow ( CFM) 4. AHU power consumption 5. Chilled water in/out Temp 6. Common Alarm Controller shall also have fire trip alarm to shut AHU incase of signal from fire panel

-

-

-

... More
8.0 TR (3000 CFM) ESP 20 MM

1

-

-

... More
Supply, installation testing & commissioning EUROVENT CERTIFIED Horizontal / vertical floor mount Airhandling units having following specifications. Frame Structure consisting of 45mm Extruded Aluminium Thermal break profile Panel: 45mm +/- 2mm thick double skin sandwich panels with Puff insulation of density 48 kg/cum , The sheet thickness shall be minimum 0.8 mm for the outer skin and 0.8 mm thickness for the inner skin of GI . Filtration Section shall be provided with 2 stage washable type of 'MERV8 ' first stage and 'MERV13' final stage. Coil Section: Chilled water coil Minimum 6 row deep constructed with Aluminium fins of minimum 0.11mm thickness and copper tubes of minimum 29Guage thickness. Copper tube shall be 9.6mm or 12.5mm diameter. The coil face area shall not exceed 2.5m/sec. Coil shal be provided with copper header. Inbuilt UV Lamp to be considered upstream or downstream of the coil based on OEM recommendation with necessary interlock with the AHU whenver the AHU is shutoff, UV lamp shall be off and vice versa. Drain Pan: Condensate drain pan shall be fabricated from 20 G SS 304 powder coated, insulated with 19 mm thick closed cell elastomeric insulation. Fan Section: Direct drive backward curved EC fan ( Electronically commutated ) with permanent magnet brushless DC motor for stepless variation of speed of fan based on temperature sensor inputs. The fan section shall be provided with limt switch for safety to shut off fan during Opening of access door.

-

-

-

... More
AHU mounted graphical display with starter Panel with Auto /Manual switch and incomer power terminal. all internal cablings between panel and motor/ door interlocks / marine lamp etc should be considered Instrumentation Kit to be provided to give out the following option 1. Supply air temperature 2. Return air temperature 3. Chilled water in temperature 4. Chilled water out temperatue 5. DP switch across filter for fitler clog Controller module with RS 485 port compatible with BMS, on board protocol with touch screen to display following 1. EC fan operation status 2. Chilled water valve operation status 3. AHU Airflow ( CFM) 4. AHU power consumption 5. Chilled water in/out Temp 6. Common Alarm Controller shall also have fire trip alarm to shut AHU incase of signal from fire panel

-

-

-

... More
10.0 TR (4000 CFM) ESP 20 MM

8

-

-

... More
Supply, installation testing & commissioning EUROVENT CERTIFIED Horizontal / vertical floor mount Airhandling units having following specifications. Frame Structure consisting of 45mm Extruded Aluminium Thermal break profile Panel: 45mm +/- 2mm thick double skin sandwich panels with Puff insulation of density 48 kg/cum , The sheet thickness shall be minimum 0.8 mm for the outer skin and 0.8 mm thickness for the inner skin of GI . Filtration Section shall be provided with 2 stage washable type of 'MERV8 ' first stage and 'MERV13' final stage. Coil Section: Chilled water coil Minimum 6 row deep constructed with Aluminium fins of minimum 0.11mm thickness and copper tubes of minimum 29Guage thickness. Copper tube shall be 9.6mm or 12.5mm diameter. The coil face area shall not exceed 2.5m/sec. Coil shal be provided with copper header. Inbuilt UV Lamp to be considered upstream or downstream of the coil based on OEM recommendation with necessary interlock with the AHU whenver the AHU is shutoff, UV lamp shall be off and vice versa. Drain Pan: Condensate drain pan shall be fabricated from 20 G SS 304 powder coated, insulated with 19 mm thick closed cell elastomeric insulation. Fan Section: Direct drive backward curved EC fan ( Electronically commutated ) with permanent magnet brushless DC motor for stepless variation of speed of fan based on temperature sensor inputs. The fan section shall be provided with limt switch for safety to shut off fan during Opening of access door.

-

-

-

... More
AHU mounted graphical display with starter Panel with Auto /Manual switch and incomer power terminal. all internal cablings between panel and motor/ door interlocks / marine lamp etc should be considered Instrumentation Kit to be provided to give out the following option 1. Supply air temperature 2. Return air temperature 3. Chilled water in temperature 4. Chilled water out temperatue 5. DP switch across filter for fitler clog Controller module with RS 485 port compatible with BMS, on board protocol with touch screen to display following 1. EC fan operation status 2. Chilled water valve operation status 3. AHU Airflow ( CFM) 4. AHU power consumption 5. Chilled water in/out Temp 6. Common Alarm Controller shall also have fire trip alarm to shut AHU incase of signal from fire panel

-

-

-

... More
12.0 TR (4800 CFM) ESP 30 MM

10

-

-

... More
Supply, installation testing & commissioning EUROVENT CERTIFIED Horizontal / vertical floor mount Airhandling units having following specifications. Frame Structure consisting of 45mm Extruded Aluminium Thermal break profile Panel: 45mm +/- 2mm thick double skin sandwich panels with Puff insulation of density 48 kg/cum , The sheet thickness shall be minimum 0.8 mm for the outer skin and 0.8 mm thickness for the inner skin of GI . Filtration Section shall be provided with 2 stage washable type of 'MERV8 ' first stage and 'MERV13' final stage. Coil Section: Chilled water coil Minimum 6 row deep constructed with Aluminium fins of minimum 0.11mm thickness and copper tubes of minimum 29Guage thickness. Copper tube shall be 9.6mm or 12.5mm diameter. The coil face area shall not exceed 2.5m/sec. Coil shal be provided with copper header. Inbuilt UV Lamp to be considered upstream or downstream of the coil based on OEM recommendation with necessary interlock with the AHU whenver the AHU is shutoff, UV lamp shall be off and vice versa. Drain Pan: Condensate drain pan shall be fabricated from 20 G SS 304 powder coated, insulated with 19 mm thick closed cell elastomeric insulation. Fan Section: Direct drive backward curved EC fan ( Electronically commutated ) with permanent magnet brushless DC motor for stepless variation of speed of fan based on temperature sensor inputs. The fan section shall be provided with limt switch for safety to shut off fan during Opening of access door.

-

-

-

... More
AHU mounted graphical display with starter Panel with Auto /Manual switch and incomer power terminal. all internal cablings between panel and motor/ door interlocks / marine lamp etc should be considered Instrumentation Kit to be provided to give out the following option 1. Supply air temperature 2. Return air temperature 3. Chilled water in temperature 4. Chilled water out temperatue 5. DP switch across filter for fitler clog Controller module with RS 485 port compatible with BMS, on board protocol with touch screen to display following 1. EC fan operation status 2. Chilled water valve operation status 3. AHU Airflow ( CFM) 4. AHU power consumption 5. Chilled water in/out Temp 6. Common Alarm Controller shall also have fire trip alarm to shut AHU incase of signal from fire panel

-

-

-

... More
14.0 TR (5600 CFM) ESP 30 MM

1

-

-

... More
AHU mounted graphical display with starter Panel with Auto /Manual switch and incomer power terminal. all internal cablings between panel and motor/ door interlocks / marine lamp etc should be considered Instrumentation Kit to be provided to give out the following option 1. Supply air temperature 2. Return air temperature 3. Chilled water in temperature 4. Chilled water out temperatue 5. DP switch across filter for fitler clog Controller module with RS 485 port compatible with BMS, on board protocol with touch screen to display following 1. EC fan operation status 2. Chilled water valve operation status 3. AHU Airflow ( CFM) 4. AHU power consumption 5. Chilled water in/out Temp 6. Common Alarm Controller shall also have fire trip alarm to shut AHU incase of signal from fire panel

-

-

-

... More
15.0 TR (6750 CFM) ESP 30 MM

2

-

-

... More
Supply, installation testing & commissioning EUROVENT CERTIFIED Horizontal / vertical floor mount Airhandling units having following specifications. Frame Structure consisting of 45mm Extruded Aluminium Thermal break profile Panel: 45mm +/- 2mm thick double skin sandwich panels with Puff insulation of density 48 kg/cum , The sheet thickness shall be minimum 0.8 mm for the outer skin and 0.8 mm thickness for the inner skin of GI . Filtration Section shall be provided with 2 stage washable type of 'MERV8 ' first stage and 'MERV13' final stage. Coil Section: Chilled water coil Minimum 6 row deep constructed with Aluminium fins of minimum 0.11mm thickness and copper tubes of minimum 29Guage thickness. Copper tube shall be 9.6mm or 12.5mm diameter. The coil face area shall not exceed 2.5m/sec. Coil shal be provided with copper header. Inbuilt UV Lamp to be considered upstream or downstream of the coil based on OEM recommendation with necessary interlock with the AHU whenver the AHU is shutoff, UV lamp shall be off and vice versa. Drain Pan: Condensate drain pan shall be fabricated from 20 G SS 304 powder coated, insulated with 19 mm thick closed cell elastomeric insulation. Fan Section: Direct drive backward curved EC fan ( Electronically commutated ) with permanent magnet brushless DC motor for stepless variation of speed of fan based on temperature sensor inputs. The fan section shall be provided with limt switch for safety to shut off fan during Opening of access door.

-

-

-

... More
AHU mounted graphical display with starter Panel with Auto /Manual switch and incomer power terminal. all internal cablings between panel and motor/ door interlocks / marine lamp etc should be considered Instrumentation Kit to be provided to give out the following option 1. Supply air temperature 2. Return air temperature 3. Chilled water in temperature 4. Chilled water out temperatue 5. DP switch across filter for fitler clog Controller module with RS 485 port compatible with BMS, on board protocol with touch screen to display following 1. EC fan operation status 2. Chilled water valve operation status 3. AHU Airflow ( CFM) 4. AHU power consumption 5. Chilled water in/out Temp 6. Common Alarm Controller shall also have fire trip alarm to shut AHU incase of signal from fire panel

-

-

-

... More
17.0 TR (7650 CFM) ESP 30 MM

3

-

-

... More
Supply, installation testing & commissioning EUROVENT CERTIFIED Horizontal / vertical floor mount Airhandling units having following specifications. Frame Structure consisting of 45mm Extruded Aluminium Thermal break profile Panel: 45mm +/- 2mm thick double skin sandwich panels with Puff insulation of density 48 kg/cum , The sheet thickness shall be minimum 0.8 mm for the outer skin and 0.8 mm thickness for the inner skin of GI . Filtration Section shall be provided with 2 stage washable type of 'MERV8 ' first stage and 'MERV13' final stage. Coil Section: Chilled water coil Minimum 6 row deep constructed with Aluminium fins of minimum 0.11mm thickness and copper tubes of minimum 29Guage thickness. Copper tube shall be 9.6mm or 12.5mm diameter. The coil face area shall not exceed 2.5m/sec. Coil shal be provided with copper header. Inbuilt UV Lamp to be considered upstream or downstream of the coil based on OEM recommendation with necessary interlock with the AHU whenver the AHU is shutoff, UV lamp shall be off and vice versa. Drain Pan: Condensate drain pan shall be fabricated from 20 G SS 304 powder coated, insulated with 19 mm thick closed cell elastomeric insulation. Fan Section: Direct drive backward curved EC fan ( Electronically commutated ) with permanent magnet brushless DC motor for stepless variation of speed of fan based on temperature sensor inputs. The fan section shall be provided with limt switch for safety to shut off fan during Opening of access door.

-

-

-

... More
AHU mounted graphical display with starter Panel with Auto /Manual switch and incomer power terminal. all internal cablings between panel and motor/ door interlocks / marine lamp etc should be considered Instrumentation Kit to be provided to give out the following option 1. Supply air temperature 2. Return air temperature 3. Chilled water in temperature 4. Chilled water out temperatue 5. DP switch across filter for fitler clog Controller module with RS 485 port compatible with BMS, on board protocol with touch screen to display following 1. EC fan operation status 2. Chilled water valve operation status 3. AHU Airflow ( CFM) 4. AHU power consumption 5. Chilled water in/out Temp 6. Common Alarm Controller shall also have fire trip alarm to shut AHU incase of signal from fire panel

-

-

-

... More
20.0 TR (8000 CFM) ESP 30 MM

6

-

-

... More
Supply, installation testing & commissioning EUROVENT CERTIFIED Horizontal / vertical floor mount Airhandling units having following specifications. Frame Structure consisting of 45mm Extruded Aluminium Thermal break profile Panel: 45mm +/- 2mm thick double skin sandwich panels with Puff insulation of density 48 kg/cum , The sheet thickness shall be minimum 0.8 mm for the outer skin and 0.8 mm thickness for the inner skin of GI . Filtration Section shall be provided with 2 stage washable type of 'MERV8 ' first stage and 'MERV13' final stage. Coil Section: Chilled water coil Minimum 6 row deep constructed with Aluminium fins of minimum 0.11mm thickness and copper tubes of minimum 29Guage thickness. Copper tube shall be 9.6mm or 12.5mm diameter. The coil face area shall not exceed 2.5m/sec. Coil shal be provided with copper header. Inbuilt UV Lamp to be considered upstream or downstream of the coil based on OEM recommendation with necessary interlock with the AHU whenver the AHU is shutoff, UV lamp shall be off and vice versa. Drain Pan: Condensate drain pan shall be fabricated from 20 G SS 304 powder coated, insulated with 19 mm thick closed cell elastomeric insulation. Fan Section: Direct drive backward curved EC fan ( Electronically commutated ) with permanent magnet brushless DC motor for stepless variation of speed of fan based on temperature sensor inputs. The fan section shall be provided with limt switch for safety to shut off fan during Opening of access door.

-

-

-

... More
AHU mounted graphical display with starter Panel with Auto /Manual switch and incomer power terminal. all internal cablings between panel and motor/ door interlocks / marine lamp etc should be considered Instrumentation Kit to be provided to give out the following option 1. Supply air temperature 2. Return air temperature 3. Chilled water in temperature 4. Chilled water out temperatue 5. DP switch across filter for fitler clog Controller module with RS 485 port compatible with BMS, on board protocol with touch screen to display following 1. EC fan operation status 2. Chilled water valve operation status 3. AHU Airflow ( CFM) 4. AHU power consumption 5. Chilled water in/out Temp 6. Common Alarm Controller shall also have fire trip alarm to shut AHU incase of signal from fire panel

-

-

-

... More
20.0 TR (9000 CFM) ESP 30 MM

3

-

-

... More
Supply, installation testing & commissioning EUROVENT CERTIFIED Horizontal / vertical floor mount Airhandling units having following specifications. Frame Structure consisting of 45mm Extruded Aluminium Thermal break profile Panel: 45mm +/- 2mm thick double skin sandwich panels with Puff insulation of density 48 kg/cum , The sheet thickness shall be minimum 0.8 mm for the outer skin and 0.8 mm thickness for the inner skin of GI . Filtration Section shall be provided with 2 stage washable type of 'MERV8 ' first stage and 'MERV13' final stage. Coil Section: Chilled water coil Minimum 6 row deep constructed with Aluminium fins of minimum 0.11mm thickness and copper tubes of minimum 29Guage thickness. Copper tube shall be 9.6mm or 12.5mm diameter. The coil face area shall not exceed 2.5m/sec. Coil shal be provided with copper header. Inbuilt UV Lamp to be considered upstream or downstream of the coil based on OEM recommendation with necessary interlock with the AHU whenver the AHU is shutoff, UV lamp shall be off and vice versa. Drain Pan: Condensate drain pan shall be fabricated from 20 G SS 304 powder coated, insulated with 19 mm thick closed cell elastomeric insulation. Fan Section: Direct drive backward curved EC fan ( Electronically commutated ) with permanent magnet brushless DC motor for stepless variation of speed of fan based on temperature sensor inputs. The fan section shall be provided with limt switch for safety to shut off fan during Opening of access door.

-

-

-

... More
AHU mounted graphical display with starter Panel with Auto /Manual switch and incomer power terminal. all internal cablings between panel and motor/ door interlocks / marine lamp etc should be considered Instrumentation Kit to be provided to give out the following option 1. Supply air temperature 2. Return air temperature 3. Chilled water in temperature 4. Chilled water out temperatue 5. DP switch across filter for fitler clog Controller module with RS 485 port compatible with BMS, on board protocol with touch screen to display following 1. EC fan operation status 2. Chilled water valve operation status 3. AHU Airflow ( CFM) 4. AHU power consumption 5. Chilled water in/out Temp 6. Common Alarm Controller shall also have fire trip alarm to shut AHU incase of signal from fire panel

-

-

-

... More
21.0 TR (8400 CFM) ESP 35 MM

1

-

-

... More
Supply, installation testing & commissioning EUROVENT CERTIFIED Horizontal / vertical floor mount Airhandling units having following specifications. Frame Structure consisting of 45mm Extruded Aluminium Thermal break profile Panel: 45mm +/- 2mm thick double skin sandwich panels with Puff insulation of density 48 kg/cum , The sheet thickness shall be minimum 0.8 mm for the outer skin and 0.8 mm thickness for the inner skin of GI . Filtration Section shall be provided with 2 stage washable type of 'MERV8 ' first stage and 'MERV13' final stage. Coil Section: Chilled water coil Minimum 6 row deep constructed with Aluminium fins of minimum 0.11mm thickness and copper tubes of minimum 29Guage thickness. Copper tube shall be 9.6mm or 12.5mm diameter. The coil face area shall not exceed 2.5m/sec. Coil shal be provided with copper header. Inbuilt UV Lamp to be considered upstream or downstream of the coil based on OEM recommendation with necessary interlock with the AHU whenver the AHU is shutoff, UV lamp shall be off and vice versa. Drain Pan: Condensate drain pan shall be fabricated from 20 G SS 304 powder coated, insulated with 19 mm thick closed cell elastomeric insulation. Fan Section: Direct drive backward curved EC fan ( Electronically commutated ) with permanent magnet brushless DC motor for stepless variation of speed of fan based on temperature sensor inputs. The fan section shall be provided with limt switch for safety to shut off fan during Opening of access door.

-

-

-

... More
AHU mounted graphical display with starter Panel with Auto /Manual switch and incomer power terminal. all internal cablings between panel and motor/ door interlocks / marine lamp etc should be considered Instrumentation Kit to be provided to give out the following option 1. Supply air temperature 2. Return air temperature 3. Chilled water in temperature 4. Chilled water out temperatue 5. DP switch across filter for fitler clog Controller module with RS 485 port compatible with BMS, on board protocol with touch screen to display following 1. EC fan operation status 2. Chilled water valve operation status 3. AHU Airflow ( CFM) 4. AHU power consumption 5. Chilled water in/out Temp 6. Common Alarm Controller shall also have fire trip alarm to shut AHU incase of signal from fire panel

-

-

-

... More
21.0 TR (9450 CFM) ESP 35 MM

6

-

-

... More
Supply, installation testing & commissioning EUROVENT CERTIFIED Horizontal / vertical floor mount Airhandling units having following specifications. Frame Structure consisting of 45mm Extruded Aluminium Thermal break profile Panel: 45mm +/- 2mm thick double skin sandwich panels with Puff insulation of density 48 kg/cum , The sheet thickness shall be minimum 0.8 mm for the outer skin and 0.8 mm thickness for the inner skin of GI . Filtration Section shall be provided with 2 stage washable type of 'MERV8 ' first stage and 'MERV13' final stage. Coil Section: Chilled water coil Minimum 6 row deep constructed with Aluminium fins of minimum 0.11mm thickness and copper tubes of minimum 29Guage thickness. Copper tube shall be 9.6mm or 12.5mm diameter. The coil face area shall not exceed 2.5m/sec. Coil shal be provided with copper header. Inbuilt UV Lamp to be considered upstream or downstream of the coil based on OEM recommendation with necessary interlock with the AHU whenver the AHU is shutoff, UV lamp shall be off and vice versa. Drain Pan: Condensate drain pan shall be fabricated from 20 G SS 304 powder coated, insulated with 19 mm thick closed cell elastomeric insulation. Fan Section: Direct drive backward curved EC fan ( Electronically commutated ) with permanent magnet brushless DC motor for stepless variation of speed of fan based on temperature sensor inputs. The fan section shall be provided with limt switch for safety to shut off fan during Opening of access door.

-

-

-

... More
AHU mounted graphical display with starter Panel with Auto /Manual switch and incomer power terminal. all internal cablings between panel and motor/ door interlocks / marine lamp etc should be considered Instrumentation Kit to be provided to give out the following option 1. Supply air temperature 2. Return air temperature 3. Chilled water in temperature 4. Chilled water out temperatue 5. DP switch across filter for fitler clog Controller module with RS 485 port compatible with BMS, on board protocol with touch screen to display following 1. EC fan operation status 2. Chilled water valve operation status 3. AHU Airflow ( CFM) 4. AHU power consumption 5. Chilled water in/out Temp 6. Common Alarm Controller shall also have fire trip alarm to shut AHU incase of signal from fire panel

-

-

-

... More
22.0 TR (8800 CFM) ESP 35 MM

5

-

-

... More
Supply, installation testing & commissioning EUROVENT CERTIFIED Horizontal / vertical floor mount Airhandling units having following specifications. Frame Structure consisting of 45mm Extruded Aluminium Thermal break profile Panel: 45mm +/- 2mm thick double skin sandwich panels with Puff insulation of density 48 kg/cum , The sheet thickness shall be minimum 0.8 mm for the outer skin and 0.8 mm thickness for the inner skin of GI . Filtration Section shall be provided with 2 stage washable type of 'MERV8 ' first stage and 'MERV13' final stage. Coil Section: Chilled water coil Minimum 6 row deep constructed with Aluminium fins of minimum 0.11mm thickness and copper tubes of minimum 29Guage thickness. Copper tube shall be 9.6mm or 12.5mm diameter. The coil face area shall not exceed 2.5m/sec. Coil shal be provided with copper header. Inbuilt UV Lamp to be considered upstream or downstream of the coil based on OEM recommendation with necessary interlock with the AHU whenver the AHU is shutoff, UV lamp shall be off and vice versa. Drain Pan: Condensate drain pan shall be fabricated from 20 G SS 304 powder coated, insulated with 19 mm thick closed cell elastomeric insulation. Fan Section: Direct drive backward curved EC fan ( Electronically commutated ) with permanent magnet brushless DC motor for stepless variation of speed of fan based on temperature sensor inputs. The fan section shall be provided with limt switch for safety to shut off fan during Opening of access door.

-

-

-

... More
AHU mounted graphical display with starter Panel with Auto /Manual switch and incomer power terminal. all internal cablings between panel and motor/ door interlocks / marine lamp etc should be considered Instrumentation Kit to be provided to give out the following option 1. Supply air temperature 2. Return air temperature 3. Chilled water in temperature 4. Chilled water out temperatue 5. DP switch across filter for fitler clog Controller module with RS 485 port compatible with BMS, on board protocol with touch screen to display following 1. EC fan operation status 2. Chilled water valve operation status 3. AHU Airflow ( CFM) 4. AHU power consumption 5. Chilled water in/out Temp 6. Common Alarm Controller shall also have fire trip alarm to shut AHU incase of signal from fire panel

-

-

-

... More
22.0 TR (9900 CFM) ESP 35 MM

5

-

-

... More
Supply, installation testing & commissioning EUROVENT CERTIFIED Horizontal / vertical floor mount Airhandling units having following specifications. Frame Structure consisting of 45mm Extruded Aluminium Thermal break profile Panel: 45mm +/- 2mm thick double skin sandwich panels with Puff insulation of density 48 kg/cum , The sheet thickness shall be minimum 0.8 mm for the outer skin and 0.8 mm thickness for the inner skin of GI . Filtration Section shall be provided with 2 stage washable type of 'MERV8 ' first stage and 'MERV13' final stage. Coil Section: Chilled water coil Minimum 6 row deep constructed with Aluminium fins of minimum 0.11mm thickness and copper tubes of minimum 29Guage thickness. Copper tube shall be 9.6mm or 12.5mm diameter. The coil face area shall not exceed 2.5m/sec. Coil shal be provided with copper header. Inbuilt UV Lamp to be considered upstream or downstream of the coil based on OEM recommendation with necessary interlock with the AHU whenver the AHU is shutoff, UV lamp shall be off and vice versa. Drain Pan: Condensate drain pan shall be fabricated from 20 G SS 304 powder coated, insulated with 19 mm thick closed cell elastomeric insulation. Fan Section: Direct drive backward curved EC fan ( Electronically commutated ) with permanent magnet brushless DC motor for stepless variation of speed of fan based on temperature sensor inputs. The fan section shall be provided with limt switch for safety to shut off fan during Opening of access door.

-

-

-

... More
AHU mounted graphical display with starter Panel with Auto /Manual switch and incomer power terminal. all internal cablings between panel and motor/ door interlocks / marine lamp etc should be considered Instrumentation Kit to be provided to give out the following option 1. Supply air temperature 2. Return air temperature 3. Chilled water in temperature 4. Chilled water out temperatue 5. DP switch across filter for fitler clog Controller module with RS 485 port compatible with BMS, on board protocol with touch screen to display following 1. EC fan operation status 2. Chilled water valve operation status 3. AHU Airflow ( CFM) 4. AHU power consumption 5. Chilled water in/out Temp 6. Common Alarm Controller shall also have fire trip alarm to shut AHU incase of signal from fire panel

-

-

-

... More
23.0 TR (9200 CFM) ESP 35 MM

4

-

-

... More
Supply, installation testing & commissioning EUROVENT CERTIFIED Horizontal / vertical floor mount Airhandling units having following specifications. Frame Structure consisting of 45mm Extruded Aluminium Thermal break profile Panel: 45mm +/- 2mm thick double skin sandwich panels with Puff insulation of density 48 kg/cum , The sheet thickness shall be minimum 0.8 mm for the outer skin and 0.8 mm thickness for the inner skin of GI . Filtration Section shall be provided with 2 stage washable type of 'MERV8 ' first stage and 'MERV13' final stage. Coil Section: Chilled water coil Minimum 6 row deep constructed with Aluminium fins of minimum 0.11mm thickness and copper tubes of minimum 29Guage thickness. Copper tube shall be 9.6mm or 12.5mm diameter. The coil face area shall not exceed 2.5m/sec. Coil shal be provided with copper header. Inbuilt UV Lamp to be considered upstream or downstream of the coil based on OEM recommendation with necessary interlock with the AHU whenver the AHU is shutoff, UV lamp shall be off and vice versa. Drain Pan: Condensate drain pan shall be fabricated from 20 G SS 304 powder coated, insulated with 19 mm thick closed cell elastomeric insulation. Fan Section: Direct drive backward curved EC fan ( Electronically commutated ) with permanent magnet brushless DC motor for stepless variation of speed of fan based on temperature sensor inputs. The fan section shall be provided with limt switch for safety to shut off fan during Opening of access door.

-

-

-

... More
AHU mounted graphical display with starter Panel with Auto /Manual switch and incomer power terminal. all internal cablings between panel and motor/ door interlocks / marine lamp etc should be considered Instrumentation Kit to be provided to give out the following option 1. Supply air temperature 2. Return air temperature 3. Chilled water in temperature 4. Chilled water out temperatue 5. DP switch across filter for fitler clog Controller module with RS 485 port compatible with BMS, on board protocol with touch screen to display following 1. EC fan operation status 2. Chilled water valve operation status 3. AHU Airflow ( CFM) 4. AHU power consumption 5. Chilled water in/out Temp 6. Common Alarm Controller shall also have fire trip alarm to shut AHU incase of signal from fire panel

-

-

-

... More
23.0 TR (10350 CFM) ESP 35 MM

1

-

-

... More
Supply, installation testing & commissioning EUROVENT CERTIFIED Horizontal / vertical floor mount Airhandling units having following specifications. Frame Structure consisting of 45mm Extruded Aluminium Thermal break profile Panel: 45mm +/- 2mm thick double skin sandwich panels with Puff insulation of density 48 kg/cum , The sheet thickness shall be minimum 0.8 mm for the outer skin and 0.8 mm thickness for the inner skin of GI . Filtration Section shall be provided with 2 stage washable type of 'MERV8 ' first stage and 'MERV13' final stage. Coil Section: Chilled water coil Minimum 6 row deep constructed with Aluminium fins of minimum 0.11mm thickness and copper tubes of minimum 29Guage thickness. Copper tube shall be 9.6mm or 12.5mm diameter. The coil face area shall not exceed 2.5m/sec. Coil shal be provided with copper header. Inbuilt UV Lamp to be considered upstream or downstream of the coil based on OEM recommendation with necessary interlock with the AHU whenver the AHU is shutoff, UV lamp shall be off and vice versa. Drain Pan: Condensate drain pan shall be fabricated from 20 G SS 304 powder coated, insulated with 19 mm thick closed cell elastomeric insulation. Fan Section: Direct drive backward curved EC fan ( Electronically commutated ) with permanent magnet brushless DC motor for stepless variation of speed of fan based on temperature sensor inputs. The fan section shall be provided with limt switch for safety to shut off fan during Opening of access door.

-

-

-

... More
AHU mounted graphical display with starter Panel with Auto /Manual switch and incomer power terminal. all internal cablings between panel and motor/ door interlocks / marine lamp etc should be considered Instrumentation Kit to be provided to give out the following option 1. Supply air temperature 2. Return air temperature 3. Chilled water in temperature 4. Chilled water out temperatue 5. DP switch across filter for fitler clog Controller module with RS 485 port compatible with BMS, on board protocol with touch screen to display following 1. EC fan operation status 2. Chilled water valve operation status 3. AHU Airflow ( CFM) 4. AHU power consumption 5. Chilled water in/out Temp 6. Common Alarm Controller shall also have fire trip alarm to shut AHU incase of signal from fire panel

-

-

-

... More
24.0 TR (9600 CFM) ESP 35 MM

1

-

-

... More
Supply, installation testing & commissioning EUROVENT CERTIFIED Horizontal / vertical floor mount Airhandling units having following specifications. Frame Structure consisting of 45mm Extruded Aluminium Thermal break profile Panel: 45mm +/- 2mm thick double skin sandwich panels with Puff insulation of density 48 kg/cum , The sheet thickness shall be minimum 0.8 mm for the outer skin and 0.8 mm thickness for the inner skin of GI . Filtration Section shall be provided with 2 stage washable type of 'MERV8 ' first stage and 'MERV13' final stage. Coil Section: Chilled water coil Minimum 6 row deep constructed with Aluminium fins of minimum 0.11mm thickness and copper tubes of minimum 29Guage thickness. Copper tube shall be 9.6mm or 12.5mm diameter. The coil face area shall not exceed 2.5m/sec. Coil shal be provided with copper header. Inbuilt UV Lamp to be considered upstream or downstream of the coil based on OEM recommendation with necessary interlock with the AHU whenver the AHU is shutoff, UV lamp shall be off and vice versa. Drain Pan: Condensate drain pan shall be fabricated from 20 G SS 304 powder coated, insulated with 19 mm thick closed cell elastomeric insulation. Fan Section: Direct drive backward curved EC fan ( Electronically commutated ) with permanent magnet brushless DC motor for stepless variation of speed of fan based on temperature sensor inputs. The fan section shall be provided with limt switch for safety to shut off fan during Opening of access door.

-

-

-

... More
AHU mounted graphical display with starter Panel with Auto /Manual switch and incomer power terminal. all internal cablings between panel and motor/ door interlocks / marine lamp etc should be considered Instrumentation Kit to be provided to give out the following option 1. Supply air temperature 2. Return air temperature 3. Chilled water in temperature 4. Chilled water out temperatue 5. DP switch across filter for fitler clog Controller module with RS 485 port compatible with BMS, on board protocol with touch screen to display following 1. EC fan operation status 2. Chilled water valve operation status 3. AHU Airflow ( CFM) 4. AHU power consumption 5. Chilled water in/out Temp 6. Common Alarm Controller shall also have fire trip alarm to shut AHU incase of signal from fire panel

-

-

-

... More
24.0 TR (10800 CFM) ESP 35 MM

6

-

-

... More
Supply, installation testing & commissioning EUROVENT CERTIFIED Horizontal / vertical floor mount Airhandling units having following specifications. Frame Structure consisting of 45mm Extruded Aluminium Thermal break profile Panel: 45mm +/- 2mm thick double skin sandwich panels with Puff insulation of density 48 kg/cum , The sheet thickness shall be minimum 0.8 mm for the outer skin and 0.8 mm thickness for the inner skin of GI . Filtration Section shall be provided with 2 stage washable type of 'MERV8 ' first stage and 'MERV13' final stage. Coil Section: Chilled water coil Minimum 6 row deep constructed with Aluminium fins of minimum 0.11mm thickness and copper tubes of minimum 29Guage thickness. Copper tube shall be 9.6mm or 12.5mm diameter. The coil face area shall not exceed 2.5m/sec. Coil shal be provided with copper header. Inbuilt UV Lamp to be considered upstream or downstream of the coil based on OEM recommendation with necessary interlock with the AHU whenver the AHU is shutoff, UV lamp shall be off and vice versa. Drain Pan: Condensate drain pan shall be fabricated from 20 G SS 304 powder coated, insulated with 19 mm thick closed cell elastomeric insulation. Fan Section: Direct drive backward curved EC fan ( Electronically commutated ) with permanent magnet brushless DC motor for stepless variation of speed of fan based on temperature sensor inputs. The fan section shall be provided with limt switch for safety to shut off fan during Opening of access door.

-

-

-

... More
AHU mounted graphical display with starter Panel with Auto /Manual switch and incomer power terminal. all internal cablings between panel and motor/ door interlocks / marine lamp etc should be considered Instrumentation Kit to be provided to give out the following option 1. Supply air temperature 2. Return air temperature 3. Chilled water in temperature 4. Chilled water out temperatue 5. DP switch across filter for fitler clog Controller module with RS 485 port compatible with BMS, on board protocol with touch screen to display following 1. EC fan operation status 2. Chilled water valve operation status 3. AHU Airflow ( CFM) 4. AHU power consumption 5. Chilled water in/out Temp 6. Common Alarm Controller shall also have fire trip alarm to shut AHU incase of signal from fire panel

-

-

-

... More
25.0 TR (12000 CFM) ESP 35 MM

1

-

-

... More
Supply, installation testing & commissioning EUROVENT CERTIFIED Horizontal / vertical floor mount Airhandling units having following specifications. Frame Structure consisting of 45mm Extruded Aluminium Thermal break profile Panel: 45mm +/- 2mm thick double skin sandwich panels with Puff insulation of density 48 kg/cum , The sheet thickness shall be minimum 0.8 mm for the outer skin and 0.8 mm thickness for the inner skin of GI . Filtration Section shall be provided with 2 stage washable type of 'MERV8 ' first stage and 'MERV13' final stage. Coil Section: Chilled water coil Minimum 6 row deep constructed with Aluminium fins of minimum 0.11mm thickness and copper tubes of minimum 29Guage thickness. Copper tube shall be 9.6mm or 12.5mm diameter. The coil face area shall not exceed 2.5m/sec. Coil shal be provided with copper header. Inbuilt UV Lamp to be considered upstream or downstream of the coil based on OEM recommendation with necessary interlock with the AHU whenver the AHU is shutoff, UV lamp shall be off and vice versa. Drain Pan: Condensate drain pan shall be fabricated from 20 G SS 304 powder coated, insulated with 19 mm thick closed cell elastomeric insulation. Fan Section: Direct drive backward curved EC fan ( Electronically commutated ) with permanent magnet brushless DC motor for stepless variation of speed of fan based on temperature sensor inputs. The fan section shall be provided with limt switch for safety to shut off fan during Opening of access door.

-

-

-

... More
AHU mounted graphical display with starter Panel with Auto /Manual switch and incomer power terminal. all internal cablings between panel and motor/ door interlocks / marine lamp etc should be considered Instrumentation Kit to be provided to give out the following option 1. Supply air temperature 2. Return air temperature 3. Chilled water in temperature 4. Chilled water out temperatue 5. DP switch across filter for fitler clog Controller module with RS 485 port compatible with BMS, on board protocol with touch screen to display following 1. EC fan operation status 2. Chilled water valve operation status 3. AHU Airflow ( CFM) 4. AHU power consumption 5. Chilled water in/out Temp 6. Common Alarm Controller shall also have fire trip alarm to shut AHU incase of signal from fire panel

-

-

-

... More
26.0 TR (11700 CFM) ESP 35 MM

3

-

-

... More
Supply, installation testing & commissioning EUROVENT CERTIFIED Horizontal / vertical floor mount Airhandling units having following specifications. Frame Structure consisting of 45mm Extruded Aluminium Thermal break profile Panel: 45mm +/- 2mm thick double skin sandwich panels with Puff insulation of density 48 kg/cum , The sheet thickness shall be minimum 0.8 mm for the outer skin and 0.8 mm thickness for the inner skin of GI . Filtration Section shall be provided with 2 stage washable type of 'MERV8 ' first stage and 'MERV13' final stage. Coil Section: Chilled water coil Minimum 6 row deep constructed with Aluminium fins of minimum 0.11mm thickness and copper tubes of minimum 29Guage thickness. Copper tube shall be 9.6mm or 12.5mm diameter. The coil face area shall not exceed 2.5m/sec. Coil shal be provided with copper header. Inbuilt UV Lamp to be considered upstream or downstream of the coil based on OEM recommendation with necessary interlock with the AHU whenver the AHU is shutoff, UV lamp shall be off and vice versa. Drain Pan: Condensate drain pan shall be fabricated from 20 G SS 304 powder coated, insulated with 19 mm thick closed cell elastomeric insulation. Fan Section: Direct drive backward curved EC fan ( Electronically commutated ) with permanent magnet brushless DC motor for stepless variation of speed of fan based on temperature sensor inputs. The fan section shall be provided with limt switch for safety to shut off fan during Opening of access door.

-

-

-

... More
AHU mounted graphical display with starter Panel with Auto /Manual switch and incomer power terminal. all internal cablings between panel and motor/ door interlocks / marine lamp etc should be considered Instrumentation Kit to be provided to give out the following option 1. Supply air temperature 2. Return air temperature 3. Chilled water in temperature 4. Chilled water out temperatue 5. DP switch across filter for fitler clog Controller module with RS 485 port compatible with BMS, on board protocol with touch screen to display following 1. EC fan operation status 2. Chilled water valve operation status 3. AHU Airflow ( CFM) 4. AHU power consumption 5. Chilled water in/out Temp 6. Common Alarm Controller shall also have fire trip alarm to shut AHU incase of signal from fire panel

-

-

-

... More
28.0 TR (11200 CFM) ESP 35 MM

2

-

-

... More
Supply, installation testing & commissioning EUROVENT CERTIFIED Horizontal / vertical floor mount Airhandling units having following specifications. Frame Structure consisting of 45mm Extruded Aluminium Thermal break profile Panel: 45mm +/- 2mm thick double skin sandwich panels with Puff insulation of density 48 kg/cum , The sheet thickness shall be minimum 0.8 mm for the outer skin and 0.8 mm thickness for the inner skin of GI . Filtration Section shall be provided with 2 stage washable type of 'MERV8 ' first stage and 'MERV13' final stage. Coil Section: Chilled water coil Minimum 6 row deep constructed with Aluminium fins of minimum 0.11mm thickness and copper tubes of minimum 29Guage thickness. Copper tube shall be 9.6mm or 12.5mm diameter. The coil face area shall not exceed 2.5m/sec. Coil shal be provided with copper header. Inbuilt UV Lamp to be considered upstream or downstream of the coil based on OEM recommendation with necessary interlock with the AHU whenver the AHU is shutoff, UV lamp shall be off and vice versa. Drain Pan: Condensate drain pan shall be fabricated from 20 G SS 304 powder coated, insulated with 19 mm thick closed cell elastomeric insulation. Fan Section: Direct drive backward curved EC fan ( Electronically commutated ) with permanent magnet brushless DC motor for stepless variation of speed of fan based on temperature sensor inputs. The fan section shall be provided with limt switch for safety to shut off fan during Opening of access door.

-

-

-

... More
AHU mounted graphical display with starter Panel with Auto /Manual switch and incomer power terminal. all internal cablings between panel and motor/ door interlocks / marine lamp etc should be considered Instrumentation Kit to be provided to give out the following option 1. Supply air temperature 2. Return air temperature 3. Chilled water in temperature 4. Chilled water out temperatue 5. DP switch across filter for fitler clog Controller module with RS 485 port compatible with BMS, on board protocol with touch screen to display following 1. EC fan operation status 2. Chilled water valve operation status 3. AHU Airflow ( CFM) 4. AHU power consumption 5. Chilled water in/out Temp 6. Common Alarm Controller shall also have fire trip alarm to shut AHU incase of signal from fire panel

-

-

-

... More
26.0 TR (11700 CFM) ESP 35 MM

3

-

-

... More
Supply, installation testing & commissioning EUROVENT CERTIFIED Horizontal / vertical floor mount Airhandling units having following specifications. Frame Structure consisting of 45mm Extruded Aluminium Thermal break profile Panel: 45mm +/- 2mm thick double skin sandwich panels with Puff insulation of density 48 kg/cum , The sheet thickness shall be minimum 0.8 mm for the outer skin and 0.8 mm thickness for the inner skin of GI . Filtration Section shall be provided with 2 stage washable type of 'MERV8 ' first stage and 'MERV13' final stage. Coil Section: Chilled water coil Minimum 6 row deep constructed with Aluminium fins of minimum 0.11mm thickness and copper tubes of minimum 29Guage thickness. Copper tube shall be 9.6mm or 12.5mm diameter. The coil face area shall not exceed 2.5m/sec. Coil shal be provided with copper header. Inbuilt UV Lamp to be considered upstream or downstream of the coil based on OEM recommendation with necessary interlock with the AHU whenver the AHU is shutoff, UV lamp shall be off and vice versa. Drain Pan: Condensate drain pan shall be fabricated from 20 G SS 304 powder coated, insulated with 19 mm thick closed cell elastomeric insulation. Fan Section: Direct drive backward curved EC fan ( Electronically commutated ) with permanent magnet brushless DC motor for stepless variation of speed of fan based on temperature sensor inputs. The fan section shall be provided with limt switch for safety to shut off fan during Opening of access door.

-

-

-

... More
AHU mounted graphical display with starter Panel with Auto /Manual switch and incomer power terminal. all internal cablings between panel and motor/ door interlocks / marine lamp etc should be considered Instrumentation Kit to be provided to give out the following option 1. Supply air temperature 2. Return air temperature 3. Chilled water in temperature 4. Chilled water out temperatue 5. DP switch across filter for fitler clog Controller module with RS 485 port compatible with BMS, on board protocol with touch screen to display following 1. EC fan operation status 2. Chilled water valve operation status 3. AHU Airflow ( CFM) 4. AHU power consumption 5. Chilled water in/out Temp 6. Common Alarm Controller shall also have fire trip alarm to shut AHU incase of signal from fire panel

-

-

-

... More
28.0 TR (12600 CFM) ESP 35 MM

1

-

-

... More
Supply, installation testing & commissioning EUROVENT CERTIFIED Horizontal / vertical floor mount Airhandling units having following specifications. Frame Structure consisting of 45mm Extruded Aluminium Thermal break profile Panel: 45mm +/- 2mm thick double skin sandwich panels with Puff insulation of density 48 kg/cum , The sheet thickness shall be minimum 0.8 mm for the outer skin and 0.8 mm thickness for the inner skin of GI . Filtration Section shall be provided with 2 stage washable type of 'MERV8 ' first stage and 'MERV13' final stage. Coil Section: Chilled water coil Minimum 6 row deep constructed with Aluminium fins of minimum 0.11mm thickness and copper tubes of minimum 29Guage thickness. Copper tube shall be 9.6mm or 12.5mm diameter. The coil face area shall not exceed 2.5m/sec. Coil shal be provided with copper header. Inbuilt UV Lamp to be considered upstream or downstream of the coil based on OEM recommendation with necessary interlock with the AHU whenver the AHU is shutoff, UV lamp shall be off and vice versa. Drain Pan: Condensate drain pan shall be fabricated from 20 G SS 304 powder coated, insulated with 19 mm thick closed cell elastomeric insulation. Fan Section: Direct drive backward curved EC fan ( Electronically commutated ) with permanent magnet brushless DC motor for stepless variation of speed of fan based on temperature sensor inputs. The fan section shall be provided with limt switch for safety to shut off fan during Opening of access door.

-

-

-

... More
AHU mounted graphical display with starter Panel with Auto /Manual switch and incomer power terminal. all internal cablings between panel and motor/ door interlocks / marine lamp etc should be considered Instrumentation Kit to be provided to give out the following option 1. Supply air temperature 2. Return air temperature 3. Chilled water in temperature 4. Chilled water out temperatue 5. DP switch across filter for fitler clog Controller module with RS 485 port compatible with BMS, on board protocol with touch screen to display following 1. EC fan operation status 2. Chilled water valve operation status 3. AHU Airflow ( CFM) 4. AHU power consumption 5. Chilled water in/out Temp 6. Common Alarm Controller shall also have fire trip alarm to shut AHU incase of signal from fire panel

-

-

-

... More
32.0 TR (14400 CFM) ESP 35 MM

2

-

-

... More
Supply, installation testing & commissioning EUROVENT CERTIFIED Horizontal / vertical floor mount Airhandling units having following specifications. Frame Structure consisting of 45mm Extruded Aluminium Thermal break profile Panel: 45mm +/- 2mm thick double skin sandwich panels with Puff insulation of density 48 kg/cum , The sheet thickness shall be minimum 0.8 mm for the outer skin and 0.8 mm thickness for the inner skin of GI . Filtration Section shall be provided with 2 stage washable type of 'MERV8 ' first stage and 'MERV13' final stage. Coil Section: Chilled water coil Minimum 6 row deep constructed with Aluminium fins of minimum 0.11mm thickness and copper tubes of minimum 29Guage thickness. Copper tube shall be 9.6mm or 12.5mm diameter. The coil face area shall not exceed 2.5m/sec. Coil shal be provided with copper header. Inbuilt UV Lamp to be considered upstream or downstream of the coil based on OEM recommendation with necessary interlock with the AHU whenver the AHU is shutoff, UV lamp shall be off and vice versa. Drain Pan: Condensate drain pan shall be fabricated from 20 G SS 304 powder coated, insulated with 19 mm thick closed cell elastomeric insulation. Fan Section: Direct drive backward curved EC fan ( Electronically commutated ) with permanent magnet brushless DC motor for stepless variation of speed of fan based on temperature sensor inputs. The fan section shall be provided with limt switch for safety to shut off fan during Opening of access door.

-

-

-

... More
AHU mounted graphical display with starter Panel with Auto /Manual switch and incomer power terminal. all internal cablings between panel and motor/ door interlocks / marine lamp etc should be considered Instrumentation Kit to be provided to give out the following option 1. Supply air temperature 2. Return air temperature 3. Chilled water in temperature 4. Chilled water out temperatue 5. DP switch across filter for fitler clog Controller module with RS 485 port compatible with BMS, on board protocol with touch screen to display following 1. EC fan operation status 2. Chilled water valve operation status 3. AHU Airflow ( CFM) 4. AHU power consumption 5. Chilled water in/out Temp 6. Common Alarm Controller shall also have fire trip alarm to shut AHU incase of signal from fire panel

-

-

-

... More
34.0 TR (13600 CFM) ESP 35 MM

1

-

-

... More
Supply, installation testing & commissioning EUROVENT CERTIFIED Horizontal / vertical floor mount Airhandling units having following specifications. Frame Structure consisting of 45mm Extruded Aluminium Thermal break profile Panel: 45mm +/- 2mm thick double skin sandwich panels with Puff insulation of density 48 kg/cum , The sheet thickness shall be minimum 0.8 mm for the outer skin and 0.8 mm thickness for the inner skin of GI . Filtration Section shall be provided with 2 stage washable type of 'MERV8 ' first stage and 'MERV13' final stage. Coil Section: Chilled water coil Minimum 6 row deep constructed with Aluminium fins of minimum 0.11mm thickness and copper tubes of minimum 29Guage thickness. Copper tube shall be 9.6mm or 12.5mm diameter. The coil face area shall not exceed 2.5m/sec. Coil shal be provided with copper header. Inbuilt UV Lamp to be considered upstream or downstream of the coil based on OEM recommendation with necessary interlock with the AHU whenver the AHU is shutoff, UV lamp shall be off and vice versa. Drain Pan: Condensate drain pan shall be fabricated from 20 G SS 304 powder coated, insulated with 19 mm thick closed cell elastomeric insulation. Fan Section: Direct drive backward curved EC fan ( Electronically commutated ) with permanent magnet brushless DC motor for stepless variation of speed of fan based on temperature sensor inputs. The fan section shall be provided with limt switch for safety to shut off fan during Opening of access door.

-

-

-

... More
AHU mounted graphical display with starter Panel with Auto /Manual switch and incomer power terminal. all internal cablings between panel and motor/ door interlocks / marine lamp etc should be considered Instrumentation Kit to be provided to give out the following option 1. Supply air temperature 2. Return air temperature 3. Chilled water in temperature 4. Chilled water out temperatue 5. DP switch across filter for fitler clog Controller module with RS 485 port compatible with BMS, on board protocol with touch screen to display following 1. EC fan operation status 2. Chilled water valve operation status 3. AHU Airflow ( CFM) 4. AHU power consumption 5. Chilled water in/out Temp 6. Common Alarm Controller shall also have fire trip alarm to shut AHU incase of signal from fire panel

-

-

-

... More
40.0 TR (17400 CFM) ESP 35 MM

2

-

-

... More
Supply, installation testing & commissioning EUROVENT CERTIFIED Horizontal / vertical floor mount Airhandling units having following specifications. Frame Structure consisting of 45mm Extruded Aluminium Thermal break profile Panel: 45mm +/- 2mm thick double skin sandwich panels with Puff insulation of density 48 kg/cum , The sheet thickness shall be minimum 0.8 mm for the outer skin and 0.8 mm thickness for the inner skin of GI . Filtration Section shall be provided with 2 stage washable type of 'MERV8 ' first stage and 'MERV13' final stage. Coil Section: Chilled water coil Minimum 6 row deep constructed with Aluminium fins of minimum 0.11mm thickness and copper tubes of minimum 29Guage thickness. Copper tube shall be 9.6mm or 12.5mm diameter. The coil face area shall not exceed 2.5m/sec. Coil shal be provided with copper header. Inbuilt UV Lamp to be considered upstream or downstream of the coil based on OEM recommendation with necessary interlock with the AHU whenver the AHU is shutoff, UV lamp shall be off and vice versa. Drain Pan: Condensate drain pan shall be fabricated from 20 G SS 304 powder coated, insulated with 19 mm thick closed cell elastomeric insulation. Fan Section: Direct drive backward curved EC fan ( Electronically commutated ) with permanent magnet brushless DC motor for stepless variation of speed of fan based on temperature sensor inputs. The fan section shall be provided with limt switch for safety to shut off fan during Opening of access door.

-

-

-

... More
AHU mounted graphical display with starter Panel with Auto /Manual switch and incomer power terminal. all internal cablings between panel and motor/ door interlocks / marine lamp etc should be considered Instrumentation Kit to be provided to give out the following option 1. Supply air temperature 2. Return air temperature 3. Chilled water in temperature 4. Chilled water out temperatue 5. DP switch across filter for fitler clog Controller module with RS 485 port compatible with BMS, on board protocol with touch screen to display following 1. EC fan operation status 2. Chilled water valve operation status 3. AHU Airflow ( CFM) 4. AHU power consumption 5. Chilled water in/out Temp 6. Common Alarm Controller shall also have fire trip alarm to shut AHU incase of signal from fire panel

-

-

-

... More
58.0 TR (17400 CFM) ESP 45 MM

2

-

-

... More
CEILING MOUNTED AIR HANDLING UNITS:

-

-

-

... More
Supply, installation testing & commissioning EUROVENT CERTIFIED Ceiling Suspended Airhandling units having following specifications. Frame Structure consisting of 45mm Extruded Aluminium Thermal break profile Panel: 45mm +/- 2mm thick double skin sandwich panels with Puff insulation of density 48 kg/cum , The sheet thickness shall be minimum 0.8 mm for the outer skin and 0.8 mm thickness for the inner skin of GI . Filtration Section shall be provided with 2 stage washable type of 'MERV8 ' first stage and 'MERV13' final stage. Coil Section: Chilled water coil Minimum 6 row deep constructed with Aluminium fins of minimum 0.11mm thickness and copper tubes of minimum 29Guage thickness. Copper tube shall be 9.6mm or 12.5mm diameter. The coil face area shall not exceed 2.5m/sec. Coil shal be provided with copper header. Inbuilt UV Lamp to be considered upstream or downstream of the coil based on OEM recommendation with necessary interlock with the AHU whenver the AHU is shutoff, UV lamp shall be off and vice versa. Drain Pan: Condensate drain pan shall be fabricated from 20 G SS 304 powder coated, insulated with 19 mm thick closed cell elastomeric insulation.

-

-

-

... More
Fan Section: Direct drive backward curved EC fan ( Electronically commutated ) of approved make with permanent magnet brushless DC motor for stepless variation of speed of fan based on temperature sensor inputs. The fan section shall be provided with limt switch for safety to shut off fan during Opening of access door. starter Panel with Auto /Manual switch and incomer power terminal. all internal cablings between panel and motor/ door interlocks / marine lamp etc should be considered Instrumentation Kit to be provided to give out the following option 1. Supply air temperature 2. Return air temperature 3. Chilled water in temperature 4. Chilled water out temperatue 5. DP switch across filter for fitler clog Controller module with RS 485 port compatible with BMS, on board protocol with touch screen to display following. Control module shall be located in a sperate control panel located on the nearest wall or at the location as defined by client /PMC 1. EC fan operation status 2. Chilled water valve operation status 3. AHU Airflow ( CFM) 4. AHU power consumption 5. Chilled water in/out Temp 6. Common Alarm Controller shall also have fire trip alarm to shut AHU incase of signal from fire panel ,Unit height should not exceed 750 mm, accordinlgy CSU dimension and fan selection to be considered.

-

-

-

... More
5.0 TR (2000 CFM) ESP 15 MM

1

-

-

... More
Supply, installation testing & commissioning EUROVENT CERTIFIED Ceiling Suspended Airhandling units having following specifications. Frame Structure consisting of 45mm Extruded Aluminium Thermal break profile Panel: 45mm +/- 2mm thick double skin sandwich panels with Puff insulation of density 48 kg/cum , The sheet thickness shall be minimum 0.8 mm for the outer skin and 0.8 mm thickness for the inner skin of GI . Filtration Section shall be provided with 2 stage washable type of 'MERV8 ' first stage and 'MERV13' final stage. Coil Section: Chilled water coil Minimum 6 row deep constructed with Aluminium fins of minimum 0.11mm thickness and copper tubes of minimum 29Guage thickness. Copper tube shall be 9.6mm or 12.5mm diameter. The coil face area shall not exceed 2.5m/sec. Coil shal be provided with copper header. Inbuilt UV Lamp to be considered upstream or downstream of the coil based on OEM recommendation with necessary interlock with the AHU whenver the AHU is shutoff, UV lamp shall be off and vice versa. Drain Pan: Condensate drain pan shall be fabricated from 20 G SS 304 powder coated, insulated with 19 mm thick closed cell elastomeric insulation.

-

-

-

... More
Fan Section: Direct drive backward curved EC fan ( Electronically commutated ) of approved make with permanent magnet brushless DC motor for stepless variation of speed of fan based on temperature sensor inputs. The fan section shall be provided with limt switch for safety to shut off fan during Opening of access door. starter Panel with Auto /Manual switch and incomer power terminal. all internal cablings between panel and motor/ door interlocks / marine lamp etc should be considered Instrumentation Kit to be provided to give out the following option 1. Supply air temperature 2. Return air temperature 3. Chilled water in temperature 4. Chilled water out temperatue 5. DP switch across filter for fitler clog Controller module with RS 485 port compatible with BMS, on board protocol with touch screen to display following. Control module shall be located in a sperate control panel located on the nearest wall or at the location as defined by client /PMC 1. EC fan operation status 2. Chilled water valve operation status 3. AHU Airflow ( CFM) 4. AHU power consumption 5. Chilled water in/out Temp 6. Common Alarm Controller shall also have fire trip alarm to shut AHU incase of signal from fire panel ,Unit height should not exceed 750 mm, accordinlgy CSU dimension and fan selection to be considered.

-

-

-

... More
8.0 TR (3200 CFM) ESP 15 MM

1

-

-

... More
Supply, installation testing & commissioning EUROVENT CERTIFIED Ceiling Suspended Airhandling units having following specifications. Frame Structure consisting of 45mm Extruded Aluminium Thermal break profile Panel: 45mm +/- 2mm thick double skin sandwich panels with Puff insulation of density 48 kg/cum , The sheet thickness shall be minimum 0.8 mm for the outer skin and 0.8 mm thickness for the inner skin of GI . Filtration Section shall be provided with 2 stage washable type of 'MERV8 ' first stage and 'MERV13' final stage. Coil Section: Chilled water coil Minimum 6 row deep constructed with Aluminium fins of minimum 0.11mm thickness and copper tubes of minimum 29Guage thickness. Copper tube shall be 9.6mm or 12.5mm diameter. The coil face area shall not exceed 2.5m/sec. Coil shal be provided with copper header. Inbuilt UV Lamp to be considered upstream or downstream of the coil based on OEM recommendation with necessary interlock with the AHU whenver the AHU is shutoff, UV lamp shall be off and vice versa. Drain Pan: Condensate drain pan shall be fabricated from 20 G SS 304 powder coated, insulated with 19 mm thick closed cell elastomeric insulation.

-

-

-

... More
Fan Section: Direct drive backward curved EC fan ( Electronically commutated )of approved make with permanent magnet brushless DC motor for stepless variation of speed of fan based on temperature sensor inputs. The fan section shall be provided with limt switch for safety to shut off fan during Opening of access door. starter Panel with Auto /Manual switch and incomer power terminal. all internal cablings between panel and motor/ door interlocks / marine lamp etc should be considered Instrumentation Kit to be provided to give out the following option 1. Supply air temperature 2. Return air temperature 3. Chilled water in temperature 4. Chilled water out temperatue 5. DP switch across filter for fitler clog Controller module with RS 485 port compatible with BMS, on board protocol with touch screen to display following. Control module shall be located in a sperate control panel located on the nearest wall or at the location as defined by client /PMC 1. EC fan operation status 2. Chilled water valve operation status 3. AHU Airflow ( CFM) 4. AHU power consumption 5. Chilled water in/out Temp 6. Common Alarm Controller shall also have fire trip alarm to shut AHU incase of signal from fire panel ,Unit height should not exceed 750 mm, accordinlgy CSU dimension and fan selection to be considered.

-

-

-

... More
10.0 TR (4000 CFM) ESP 20 MM

1

-

-

... More
Supply, installation testing & commissioning EUROVENT CERTIFIED Ceiling Suspended Airhandling units having following specifications. Frame Structure consisting of 45mm Extruded Aluminium Thermal break profile Panel: 45mm +/- 2mm thick double skin sandwich panels with Puff insulation of density 48 kg/cum , The sheet thickness shall be minimum 0.8 mm for the outer skin and 0.8 mm thickness for the inner skin of GI . Filtration Section shall be provided with 2 stage washable type of 'MERV8 ' first stage and 'MERV13' final stage. Coil Section: Chilled water coil Minimum 6 row deep constructed with Aluminium fins of minimum 0.11mm thickness and copper tubes of minimum 29Guage thickness. Copper tube shall be 9.6mm or 12.5mm diameter. The coil face area shall not exceed 2.5m/sec. Coil shal be provided with copper header. Inbuilt UV Lamp to be considered upstream or downstream of the coil based on OEM recommendation with necessary interlock with the AHU whenver the AHU is shutoff, UV lamp shall be off and vice versa. Drain Pan: Condensate drain pan shall be fabricated from 20 G SS 304 powder coated, insulated with 19 mm thick closed cell elastomeric insulation.

-

-

-

... More
Fan Section: Direct drive backward curved EC fan ( Electronically commutated ) of approved make with permanent magnet brushless DC motor for stepless variation of speed of fan based on temperature sensor inputs. The fan section shall be provided with limt switch for safety to shut off fan during Opening of access door. starter Panel with Auto /Manual switch and incomer power terminal. all internal cablings between panel and motor/ door interlocks / marine lamp etc should be considered Instrumentation Kit to be provided to give out the following option 1. Supply air temperature 2. Return air temperature 3. Chilled water in temperature 4. Chilled water out temperatue 5. DP switch across filter for fitler clog Controller module with RS 485 port compatible with BMS, on board protocol with touch screen to display following. Control module shall be located in a sperate control panel located on the nearest wall or at the location as defined by client /PMC 1. EC fan operation status 2. Chilled water valve operation status 3. AHU Airflow ( CFM) 4. AHU power consumption 5. Chilled water in/out Temp 6. Common Alarm Controller shall also have fire trip alarm to shut AHU incase of signal from fire panel ,Unit height should not exceed 750 mm, accordinlgy CSU dimension and fan selection to be considered.

-

-

-

... More
13.0 TR (5850 CFM) ESP 20 MM

1

-

-

... More
CHILLED WATER CASSETTE UNIT

-

-

-

... More
CHILLED WATER CASSETTES along with Chilled Water Valve package consisting of Ball valve with and without strainer and PIBCV self dynamic balancing cum control valve for CHW flow control and all accessories required shall be part of scope. MS to Copper connectors required to connect from the main CHW MS pipeline before connecting to unit. Dgital wireless remote shall be part of scope. Factory assembled valve station of Linear Characteristic PICV as per required dia with PT port & diaphragm, Test Point, Filter Ball Valve & Bypass Valve arrangement with Insulation Kit & Modulating Electromotive Actuator (Non Spring Return) with BMS Compatible & with Flexible Hoses Valve staton shall be located in a drip tray made of 22 G GI sheet insulated from the bottom of the sheet, tray shall be provided with a height of 50 mm minum and length/width shall be able to cover the entire valve station. UNIT shall be wth inbuilt BMS compatibility with Modbus RS485 protocol output. Unit shall swicth on/off based on remote on/off command & status ( EUROVENT CERTIFIED)

-

-

-

... More
1.0 TR ( Four way cassette)

7

-

-

... More
CHILLED WATER CASSETTES along with Chilled Water Valve package consisting of Ball valve with and without strainer and PIBCV self dynamic balancing cum control valve for CHW flow control and all accessories required shall be part of scope. MS to Copper connectors required to connect from the main CHW MS pipeline before connecting to unit. Dgital wireless remote shall be part of scope. Factory assembled valve station of Linear Characteristic PICV as per required dia with PT port & diaphragm, Test Point, Filter Ball Valve & Bypass Valve arrangement with Insulation Kit & Modulating Electromotive Actuator (Non Spring Return) with BMS Compatible & with Flexible Hoses Valve staton shall be located in a drip tray made of 22 G GI sheet insulated from the bottom of the sheet, tray shall be provided with a height of 50 mm minum and length/width shall be able to cover the entire valve station. UNIT shall be wth inbuilt BMS compatibility with Modbus RS485 protocol output. Unit shall swicth on/off based on remote on/off command & status ( EUROVENT CERTIFIED)

-

-

-

... More
1.5 TR ( Four way cassette)

10

-

-

... More
CHILLED WATER CASSETTES along with Chilled Water Valve package consisting of Ball valve with and without strainer and PIBCV self dynamic balancing cum control valve for CHW flow control and all accessories required shall be part of scope. MS to Copper connectors required to connect from the main CHW MS pipeline before connecting to unit. Dgital wireless remote shall be part of scope. Factory assembled valve station of Linear Characteristic PICV as per required dia with PT port & diaphragm, Test Point, Filter Ball Valve & Bypass Valve arrangement with Insulation Kit & Modulating Electromotive Actuator (Non Spring Return) with BMS Compatible & with Flexible Hoses Valve staton shall be located in a drip tray made of 22 G GI sheet insulated from the bottom of the sheet, tray shall be provided with a height of 50 mm minum and length/width shall be able to cover the entire valve station. UNIT shall be wth inbuilt BMS compatibility with Modbus RS485 protocol output. Unit shall swicth on/off based on remote on/off command & status ( EUROVENT CERTIFIED)

-

-

-

... More
2.0 TR ( Four way cassette)

6

-

-

... More
CHILLED WATER CASSETTES along with Chilled Water Valve package consisting of Ball valve with and without strainer and PIBCV self dynamic balancing cum control valve for CHW flow control and all accessories required shall be part of scope. MS to Copper connectors required to connect from the main CHW MS pipeline before connecting to unit. Dgital wireless remote shall be part of scope. Factory assembled valve station of Linear Characteristic PICV as per required dia with PT port & diaphragm, Test Point, Filter Ball Valve & Bypass Valve arrangement with Insulation Kit & Modulating Electromotive Actuator (Non Spring Return) with BMS Compatible & with Flexible Hoses Valve staton shall be located in a drip tray made of 22 G GI sheet insulated from the bottom of the sheet, tray shall be provided with a height of 50 mm minum and length/width shall be able to cover the entire valve station. UNIT shall be wth inbuilt BMS compatibility with Modbus RS485 protocol output. Unit shall swicth on/off based on remote on/off command & status ( EUROVENT CERTIFIED)

-

-

-

... More
2.65 TR ( Four way cassette)

5

-

-

... More
CHILLED WATER CASSETTES along with Chilled Water Valve package consisting of Ball valve with and without strainer and PIBCV self dynamic balancing cum control valve for CHW flow control and all accessories required shall be part of scope. MS to Copper connectors required to connect from the main CHW MS pipeline before connecting to unit. Dgital wireless remote shall be part of scope. Factory assembled valve station of Linear Characteristic PICV as per required dia with PT port & diaphragm, Test Point, Filter Ball Valve & Bypass Valve arrangement with Insulation Kit & Modulating Electromotive Actuator (Non Spring Return) with BMS Compatible & with Flexible Hoses Valve staton shall be located in a drip tray made of 22 G GI sheet insulated from the bottom of the sheet, tray shall be provided with a height of 50 mm minum and length/width shall be able to cover the entire valve station. UNIT shall be wth inbuilt BMS compatibility with Modbus RS485 protocol output. Unit shall swicth on/off based on remote on/off command & status ( EUROVENT CERTIFIED)

-

-

-

... More
3.0 TR ( Four way cassette)

13

-

-

... More
FAN COIL UNIT

-

-

-

... More
Supply, Installation, testing & commissioning of fan coil units as specified and shown in the drawing, data sheets etc. consisting of: i) Supply & Installation of 2-way motorized PIBC valve with actuator, 2 Nos ball valves, one of them with strainer ii) Supply & Installation of compatible room thermostat iii) Supply & Installation of Power wiring from the 5A switch socket within 2 meter along with a 5A plug top iv) Supply & Installation of Halogen Free control wiring (10C, 1.5 sq.mm) between the unit and thermostat including 25mm dia pvc conduit v) Supply & Installation of Supporting frame and suspenders vi) Supply & Installation of Earthing of motor and unit. vii) Installation of pipe (CHWS & CHWR) & 19mm thk Class 0 nitrile rubber insulation from main riser / header to the unit viii) Extended drain pan SS316, double skin with insulation. ix) Canvas connection (Fire retardant) at FCU outlet. x) 4-speed DC motor with direct drive

-

-

-

... More
1.0 TR Fan Coil Units covering all the above items High static

1

-

-

... More
Supply, Installation, testing & commissioning of fan coil units as specified and shown in the drawing, data sheets etc. consisting of: i) Supply & Installation of 2-way motorized PIBC valve with actuator, 2 Nos ball valves, one of them with strainer ii) Supply & Installation of compatible room thermostat iii) Supply & Installation of Power wiring from the 5A switch socket within 2 meter along with a 5A plug top iv) Supply & Installation of Halogen Free control wiring (10C, 1.5 sq.mm) between the unit and thermostat including 25mm dia pvc conduit v) Supply & Installation of Supporting frame and suspenders vi) Supply & Installation of Earthing of motor and unit. vii) Installation of pipe (CHWS & CHWR) & 19mm thk Class 0 nitrile rubber insulation from main riser / header to the unit viii) Extended drain pan SS316, double skin with insulation. ix) Canvas connection (Fire retardant) at FCU outlet. x) 4-speed DC motor with direct drive

-

-

-

... More
1.5 TR Fan Coil Units covering all the above items High static

1

-

-

... More
Supply, Installation, testing & commissioning of fan coil units as specified and shown in the drawing, data sheets etc. consisting of: i) Supply & Installation of 2-way motorized PIBC valve with actuator, 2 Nos ball valves, one of them with strainer ii) Supply & Installation of compatible room thermostat iii) Supply & Installation of Power wiring from the 5A switch socket within 2 meter along with a 5A plug top iv) Supply & Installation of Halogen Free control wiring (10C, 1.5 sq.mm) between the unit and thermostat including 25mm dia pvc conduit v) Supply & Installation of Supporting frame and suspenders vi) Supply & Installation of Earthing of motor and unit. vii) Installation of pipe (CHWS & CHWR) & 19mm thk Class 0 nitrile rubber insulation from main riser / header to the unit viii) Extended drain pan SS316, double skin with insulation. ix) Canvas connection (Fire retardant) at FCU outlet. x) 4-speed DC motor with direct drive

-

-

-

... More
2.0 TR Fan Coil Units covering all the above items High static

1

-

-

... More
Supply, Installation, testing & commissioning of fan coil units as specified and shown in the drawing, data sheets etc. consisting of: i) Supply & Installation of 2-way motorized PIBC valve with actuator, 2 Nos ball valves, one of them with strainer ii) Supply & Installation of compatible room thermostat iii) Supply & Installation of Power wiring from the 5A switch socket within 2 meter along with a 5A plug top iv) Supply & Installation of Halogen Free control wiring (10C, 1.5 sq.mm) between the unit and thermostat including 25mm dia pvc conduit v) Supply & Installation of Supporting frame and suspenders vi) Supply & Installation of Earthing of motor and unit. vii) Installation of pipe (CHWS & CHWR) & 19mm thk Class 0 nitrile rubber insulation from main riser / header to the unit viii) Extended drain pan SS316, double skin with insulation. ix) Canvas connection (Fire retardant) at FCU outlet. x) 4-speed DC motor with direct drive

-

-

-

... More
2.5 TR Fan Coil Units covering all the above items High Static

1

-

-

... More
HI-WALL UNIT

-

-

-

... More
Supply, installation, testing & commissioning of Chilled water type Hi-wall unit with Fan, Motor having Hi-medium-Low speed,, CHW cooling Coil of sutable RD ,Filter , controls, decorative panel & power wiring from nearest power socket to indoor unit.The units should be suitable for 10 ºF Δ T ( CHW inlet temperature should be 44 ºF and outlet should be 54 ºF, Should be inclusive with valve Kit (1 Ball valve with y strainer in the supply side & 1 Ball valve with 2 Way Control Valve in the Return Line) & should include flexible CU hose to connect the chilled water pipe line to the valve Kit.

-

-

-

... More
0.8 TR Hi wall unit

1

-

-

... More
Supply, installation, testing & commissioning of Chilled water type Hi-wall unit with Fan, Motor having Hi-medium-Low speed,, CHW cooling Coil of sutable RD ,Filter , controls, decorative panel & power wiring from nearest power socket to indoor unit.The units should be suitable for 10 ºF Δ T ( CHW inlet temperature should be 44 ºF and outlet should be 54 ºF, Should be inclusive with valve Kit (1 Ball valve with y strainer in the supply side & 1 Ball valve with 2 Way Control Valve in the Return Line) & should include flexible CU hose to connect the chilled water pipe line to the valve Kit.

-

-

-

... More
1 TR Hi wall unit

1

-

-

... More
Supply, installation, testing & commissioning of Chilled water type Hi-wall unit with Fan, Motor having Hi-medium-Low speed,, CHW cooling Coil of sutable RD ,Filter , controls, decorative panel & power wiring from nearest power socket to indoor unit.The units should be suitable for 10 ºF Δ T ( CHW inlet temperature should be 44 ºF and outlet should be 54 ºF, Should be inclusive with valve Kit (1 Ball valve with y strainer in the supply side & 1 Ball valve with 2 Way Control Valve in the Return Line) & should include flexible CU hose to connect the chilled water pipe line to the valve Kit.

-

-

-

... More
1.5 TR Hi wall unit

1

-

-

... More
INSULATED CHILLED WATER PIPE AND VALVES FOR CHILLED WATER PIPES

-

-

-

... More
Supply, erection, testing and commissioning of pre-insulated pipes for Chilled water circulation pipes. Pipes will be of Mild Steel (pipe wall thickness as indicated below) and insulation material shall be PUF as per the specification. The pre-insulated pipe shall be covered with 24 Gauge aluminium spiral casing. MS 'C' class pipes as per IS 1239 / IS 3589 with specified wall thickness cut to required lengths and installed with all Accessories Class of Pipe:- Sizes up to 150 mm shall confirm to IS 1239 Sizes above 150 mm shall confirm to IS 3589 MS 'C' class pipes up to 150 mm dia Pipe dia – mm Thickness - upto 200 mm dia - 5 mm thickness 250 mm to 350 mm dia - 6 mm thickness. above 350 mm dia - 8 mm thickness insulation details Up to 32 mm : 30mm thick 49 mm to 100 mm : 40mm thick 125mm up to 300 mm : 50 mm thick 350 & above : 75 mm thick All GI / MS supports along with accessories for a maximum height of 2-3 mtr either from the ceiling slab or floor slab shall be considered in this item.

-

-

-

... More
400 mm dia

350

-

-

... More
350 mm dia

230

-

-

... More
300 mm dia

200

-

-

... More
250 mm dia

200

-

-

... More
200 mm dia

330

-

-

... More
150 mm dia

450

-

-

... More
125 mm dia

650

-

-

... More
100 mm dia

550

-

-

... More
80 mm dia

500

-

-

... More
65 mm dia

550

-

-

... More
50 mm dia

1150

-

-

... More
40 mm dia

1150

-

-

... More
32 mm dia

1450

-

-

... More
25 mm dia

1500

-

-

... More
Supply and erection of Pre-insulated Butterfly valves (with RPUF material similar to CHW pipe insulation specifications) complete with pre-insulated end flanges / matching flanges, additional supports, fixing accessories, etc. The valve shall be gear operated for 200NB and above.

-

-

-

... More
400mm dia

6

-

-

... More
350mm dia

4

-

-

... More
300 mm dia

4

-

-

... More
250 mm dia

12

-

-

... More
200 mm dia

20

-

-

... More
150 mm dia

20

-

-

... More
125 mm dia

10

-

-

... More
100 mm dia

26

-

-

... More
80 mm dia

26

-

-

... More
65 mm dia

40

-

-

... More
50 mm dia

190

-

-

... More
40 mm dia

110

-

-

... More
32 mm dia

150

-

-

... More
25 mm dia

175

-

-

... More
Supply and erection of Pre-insulated Dual plate Check valves (with RPUF material similar to CHW pipe insulation specifications) complete with pre-insulated end flanges/matching flanges, additional supports, fixing accessories, etc.

-

-

-

... More
300 mm dia

2

-

-

... More
250 mm dia

2

-

-

... More
200 mm dia

8

-

-

... More
150 mm dia

6

-

-

... More
125 mm dia

6

-

-

... More
100 mm dia

2

-

-

... More
Design, Supply, installation, testing and commissioning of Pre-Insulated Balancing Valve (with RPUF material similar to CHW pipe insulation specifications) shall be of factory calibrated direct, acting, automatic pressure compensation type. Each valve shall limit flow rates to within ± 5 % accuracy, regardless of the system pressure fluctuations. Rate shall inclusive of additional supports, fixing accessories, thermal insulation, etc.

-

-

-

... More
300 mm dia

6

-

-

... More
250 mm dia

6

-

-

... More
200 mm dia

12

-

-

... More
150 mm dia

10

-

-

... More
125 mm dia

8

-

-

... More
100 mm dia

4

-

-

... More
80 mm dia

4

-

-

... More
Supply and erection of Pre-insulated ‘Y’ type strainer (with RPUF material similar to CHW pipe insulation specifications) with removable stainless steel screen with 3mm perforation and permanent magnet, drain piping. Rate shall inclusive of pre-insulated end flanges/matching flanges, additional supports, fixing accessories, etc.

-

-

-

... More
400 mm dia

1

-

-

... More
300 mm dia

1

-

-

... More
250 mm dia

1

-

-

... More
200 mm dia

6

-

-

... More
150 mm dia

4

-

-

... More
125 mm dia

4

-

-

... More
100 mm dia

6

-

-

... More
80 mm dia

4

-

-

... More
65 mm dia

45

-

-

... More
50 mm dia

32

-

-

... More
40 mm dia

25

-

-

... More
32 mm dia

35

-

-

... More
Design, Supply, installation, testing and commissioning of Pre-insulated Two way motorized Valves (ON / OFF Type) provided with spring return function in chilled water lines at chillers and condenser water line at cooling towers. The BMS compatible actuator of the motorized valve (with RPUF material similar to CHW pipe insulation specifications) shall have required torque, the actuator with 220 V / 24 V transformer duly encased and wired. The motorized valve & actuator shall be provided with necessary communication cables, hardware, converter, pre-insulated end flanges/matching flanges, weather proof construction, etc

-

-

-

... More
300 mm dia

1

-

-

... More
200 mm dia

3

-

-

... More
150 mm dia

2

-

-

... More
125 mm dia

2

-

-

... More
100 mm dia

1

-

-

... More
Design, Supply, Installation, testing and commissioning of Pre-insulated Flow Control Valve - Pressure independent type with Dynamic Balancing Cum 2 Way modulating valves (with RPUF material similar to CHW pipe insulation specifications) for AHUs with actuator in a single Unit of Valve provided with spring return function. The valve shall be suitable for standalone operation. Valve shall be of PN16 Rating. The BMS compatible actuator shall be supplied by the valve manufacturer and capable of accepting 2-10VDC / 4- 20 mA electric signal and shall provide similar transduced feedback output signal to control system. The minimum close off Pressure of actuator must be 1.5 times shut off head of pump as per specifications. Rate shall be inclusive of stepdown transformer, digital thermostat (modulation type) suitable for the given actuator, required length of 2Cx1.5Sqmm shielded communication cable, end flanges/matching flanges, additional supports, fixing accessories, dismantling the existing valves, thermal insulation, etc

-

-

-

... More
100 mm dia

6

-

-

... More
80 mm dia

4

-

-

... More
65 mm dia

45

-

-

... More
50 mm dia

32

-

-

... More
40 mm dia

25

-

-

... More
32 mm dia

35

-

-

... More
Supply and erection of Ball valves as per specification complete with end flanges / matching flanges, additional supports, fixing accessories, thermal insulation, etc.

-

-

-

... More
32 mm dia

18

-

-

... More
25 mm dia

171

-

-

... More
Supply, installation, testing & commissioning of Closed expansion tank with Pressurization Unit as per standards & requirements. Capacity 2000 Ltrs. Tank shall be complete with 0.5 HP Pumps required in the configuration of 1 working + 1 Stand By. The cost shall include necessary valve package & control logic panel for pump automation

2

-

-

... More
Supply, installation testing & commissioning of Bourdan Tube Pressure Guages (ALL SS TYPE) Pressure guages shall be of Bourdon (100 mm) type with range selected so that normal operation is near to middle of the scale. Syphons and cocks to be provided along with SS snubber.

250

-

-

... More
Supply, installation testing & commissioning of Thermometers - Dial Type - 4" Dia (ALL SS TYPE) Thermometers of approved make & shall be of mercury in steel type with range suitable for the temperature services. It should be installed in the thermowells as explained in the tender specifications. Extension nipple shall be provided for a minimum depth of 100 mm.

200

-

-

... More
Supply, installation testing & commissioning of Automatic Air Vents with Ball valve shall be installed at all high sections of piping as well as in the AHU room piping. The discharge from this air vents shall be piped via copper tubes of appropriate size to the nearest waste drain pipe.

200

-

-

... More
Supply, installation testing & commissioning of Gate Valves for Drain:

-

-

-

... More
32 mm dia

150

-

-

... More
25 mm dia

50

-

-

... More
19 mm dia

50

-

-

... More
Supply and installation of Insulatted Air Separators of size suitable 300NB to remove the dissolved air / gases from the chilled water loop with necessary flanges, washers, painting, etc. complete as required for Water cooled chiller

1

-

-

... More
Supply and installation of Insulatted Air Separators of size suitable 125NB to remove the dissolved air / gases from the chilled water loop with necessary flanges, washers, painting, etc. complete as required for Air cooled chiller

1

-

-

... More
CONDENSER WATER PIPE AND VALVES

-

-

-

... More
Condenser Water Piping.Suppling, fixing testing & commissioning of condenser water pipes of following sizes of MS C' Class along with nececessary clamps, vibration isolators and fittings sich as bends, tees etc. but excluding valves, strainers, gauges etc, adequately supported on rigid supports duly painted/buried in ground excavation and refilling etc, as per slecification and as required complete in all respect. Note: The pipes size 150mm & below shall be M.S C class as per IS : 1239 and pipe size above 150mm shall be welded black steel pipe heavy class as per IS : 3589, from minimum 6.35mm thick M.S. sheet for pipe upto 350mm dia. And from minimum 7mm thick MS sheet for pipes of 400mm dia and above.

-

-

-

... More
450mm dia

100

-

-

... More
400mm dia

200

-

-

... More
300 mm dia

25

-

-

... More
250 mm dia

100

-

-

... More
200 mm dia

50

-

-

... More
150 mm dia

20

-

-

... More
100 mm dia

45

-

-

... More
80 mm dia

15

-

-

... More
65 mm dia

20

-

-

... More
50 mm dia

25

-

-

... More
40 mm dia

15

-

-

... More
Supply fixing testing and commissioning of following valves, gauges and strainers for condenser water circulation as per specification.Butterfly valveManual) with C I body SS disc nitrile sheet % O - ring & PN 16 pressure rating as per specified.

-

-

-

... More
400 mm dia

3

-

-

... More
400 mm dia

3

-

-

... More
350 mm dia

1

-

-

... More
300 mm dia

1

-

-

... More
250 mm dia

18

-

-

... More
200 mm dia

5

-

-

... More
150 mm dia

1

-

-

... More
125 mm dia

3

-

-

... More
100 mm dia

5

-

-

... More
80 mm dia

1

-

-

... More
65 mm dia

2

-

-

... More
50 mm dia

5

-

-

... More
40 mm dia

1

-

-

... More
Supply fixing testing and commissioning of following valves, gauges and strainers for condenser water circulation as per specification. Non-Return Valve with dual plate of C I body SS plates vulcanized NBR seal flanged end & PN 16 pressure rating as specified.

-

-

-

... More
300 mm dia

3

-

-

... More
250 mm dia

3

-

-

... More
200 mm dia

1

-

-

... More
Design, Supply, installation, testing and commissioning of Balancing Valve shall be of factory calibrated direct, acting, automatic pressure compensation type. Each valve shall limit flow rates to within ± 5 % accuracy, regardless of the system pressure fluctuations. Rate shall inclusive of additional supports, fixing accessories, thermal insulation, etc.

-

-

-

... More
300 mm dia

3

-

-

... More
250 mm dia

9

-

-

... More
200 mm dia

4

-

-

... More
Supply and erection of ‘Y’ type strainer with removable stainless steel screen with 3mm perforation and permanent magnet, drain piping. Rate shall inclusive of matching flanges, additional supports, fixing accessories, thermal insulation, etc.

-

-

-

... More
300 mm dia

3

-

-

... More
250 mm dia

3

-

-

... More
200 mm dia

1

-

-

... More
Supplying, fixing, testing and commissioning of following sizes Motorized butterfly valve with CI Boddy, SS Disc, O-ring and minimum PN-16 pressure rating, conforming to BS 5155, IS 13095, with IP-55 actuator, capable of accepting upto 10V DC, and upto 20mA electric signal and providing simillar transduced feedback output to control system as required.

-

-

-

... More
300 mm dia

3

-

-

... More
250 mm dia

9

-

-

... More
200 mm dia

4

-

-

... More
Supply and installation of Pot strainer of size suitable for 400NB pipeline to remove the dirt particles in the condenser water loop with necessary flanges, washers, painting, etc. complete as required

1

-

-

... More
Supply, installation testing & commissioning of Flow Switch

-

-

-

... More
Flow switchsuitable for 300 mm dia pipe

3

-

-

... More
Flow switchsuitable for 250 mm dia

6

-

-

... More
Flow switchsuitable for 150 mm dia

4

-

-

... More
Flow switchsuitable for 125 mm dia

2

-

-

... More
Supply, installation testing & commissioning of Flexible connections rubber belows at Chiller Outelet, inlet & also at pump discharge as per the following sizes (In mm dia). Pressure rating of PN16 to be considered.

-

-

-

... More
300 mm dia

6

-

-

... More
250 mm dia

10

-

-

... More
200 mm dia

18

-

-

... More
150 mm dia

10

-

-

... More
125 mm dia

12

-

-

... More
Supply, installation testing & commissioning of Thermowells. Extension shall be provided for a minimum depth of 100 mm. There should be a minimum projection of 25 mm over and above insulated pipe.

4

-

-

... More
Supply, installation testing & commissioning of Binder type Test Points. Extension nipple shall be provided for a minimum depth of 100 mm. There should be a minimum projection of 25 mm over and above insulated pipe.

10

-

-

... More
DRAIN PIPE WITH INSULATIONS

-

-

-

... More
Supply Insulated PVC Condensate Drain piping as per specification as mentioned in the document insulated same as chilled water piping but without polyshield covering.Consider drip pans with drian pipe .Entire draine pipe needs to be insulated with 6mm thick closed cell Nitrile rubber. 65 mm dia

330

-

-

... More
Supply Insulated PVC Condensate Drain piping as per specification as mentioned in the document insulated same as chilled water piping but without polyshield covering.Consider drip pans with drian pipe .Entire draine pipe needs to be insulated with 6mm thick closed cell Nitrile rubber. 50 mm dia

330

-

-

... More
Supply Insulated PVC Condensate Drain piping as per specification as mentioned in the document insulated same as chilled water piping but without polyshield covering.Consider drip pans with drian pipe .Entire draine pipe needs to be insulated with 6mm thick closed cell Nitrile rubber. 40 mm dia

330

-

-

... More
Supply Insulated PVC Condensate Drain piping as per specification as mentioned in the document insulated same as chilled water piping but without polyshield covering.Consider drip pans with drian pipe .Entire draine pipe needs to be insulated with 6mm thick closed cell Nitrile rubber. 32 mm dia

250

-

-

... More
Supply Insulated PVC Condensate Drain piping as per specification as mentioned in the document insulated same as chilled water piping but without polyshield covering.Consider drip pans with drian pipe .Entire draine pipe needs to be insulated with 6mm thick closed cell Nitrile rubber. 25 mm dia

175

-

-

... More
Supply Insulated PVC Condensate Drain piping as per specification as mentioned in the document insulated same as chilled water piping but without polyshield covering.Consider drip pans with drian pipe .Entire draine pipe needs to be insulated with 6mm thick closed cell Nitrile rubber. 19 mm dia

20

-

-

... More
BTU METER AND TENNANT BILLING SYSTEM

-

-

-

... More
Supply, installation, testing and commissioning of BTU Meter - to measure the HVAC Consumption Purpose. The Unit shall include an Heat Meter Integrator, Ultrasonic type Flow meter, matched pair of Temperature Sensors (along with the protection pockets). The Integrator shall have Battery backup for 12 years, Data Logging for 15 years, 230V AC power supply provision, 8 Digit LCD Display The Unit should be capable of displaying the CHW Flow Rate, BTU / Hr, KWH, CHW Temperature. The Unit shall be with IP55 grade of protection ( Maximum Pressure drop across BTU meter 0.2 WC) The BTU Meter shall be MID approved In-Line Flange Connection type . The Integrators shall be capable of communicating on a communication bus to the BMS on one of Standard Open Protocols such as MODBUS / LON etc a) Inline Flow Meter, b) Match Pair Sensors c) Heat Integrator d) Minimum 4 Data / Meter to Master Contoroller - T1 / T2 / Flow / KWH - with 2 mtr 2C shielded communication cable

-

-

-

... More
Btu Transmitters as per the specification for tenant billing. Btu Meters shall consist of following items of following sizes:-

-

-

-

... More
300 mm dia

1

-

-

... More
250 mm dia

1

-

-

... More
200 mm dia

4

-

-

... More
150 mm dia

2

-

-

... More
125 mm dia

6

-

-

... More
100 mm dia

14

-

-

... More
80 mm dia

6

-

-

... More
65 mm dia

5

-

-

... More
50 mm dia

66

-

-

... More
40 mm dia

21

-

-

... More
32 mm dia

9

-

-

... More
25 mm dia

15

-

-

... More
Power supply cable for BTU Meters - 3 core 1.5 sqmm shielded FRLS cable including glands along with 25 mm pvc conduit

6000

-

-

... More
INTEGRATORS

-

-

-

... More
Integrators to connect all Btu/Kwh Meters to PC billing software

1

-

-

... More
Integrators to connect all Energy meters to PC with billing software

1

-

-

... More
5 KVA UPS with 30 min's Backup along with distribution Board for BTU Meters

1

-

-

... More
Power supply cable for BTU Meters - 3 core 1.5 sqmm shielded FRLS cable including glands along with 25 mm pvc conduit

6000

-

-

... More
2 Core 1.5 Sq.mm GI twisted pair shielded FRLS cable including glands along with 25 mm pvc conduit

10000

-

-

... More
CHEMICAL DOSING SYSTEM

-

-

-

... More
AUTOMIZED CHEMICAL DOZING SYSTEM - FOR OPEN LOOP (CONDENSER WATER CIRCUIT). Below are the plant room details. (refer Schematic layout and Plant room layout for additional info) 1. 375 TR X 3 Nos Water cooled chillers 2. Flow rate across condenser / cooling tower - 1312 GPM each 3. chiller located on podium-01 and cooling tower located on terrace. System shall consist of all associated accessories as per below list as minimum for effective performance

-

-

-

... More
pH Control System, Acid Dosing with following components

-

-

-

... More
pH Sensor, range: 0-14, output: mV, Body MOC: PVC

-

-

-

... More
pH Transmitter,Power: 24V DC ; Output: 4-20mA

-

-

-

... More
Metering Pumps, Max. Flow: 4LPH, Max. Injection Pressure: 5.5kg/cm2, PP/Teflon Liquidend, with accessories like foot valve, strainer, injection valve, antisyphon valve.

-

-

-

... More
PE/FRP Storage Tank, 60lts, lid with facility to mount the metering pump

-

-

-

... More
LDPE Tubing from Dosing Pump to Sampling Line Dosing Point.

-

-

-

... More
ORP Control System, Hypo Dosing with following components

-

-

-

... More
ORP Sensor, range: -1000-1000mV, output: mV, Body MOC: PVC

-

-

-

... More
ORP Transmitter; Power: 24V DC ; Output: 4-20mA

-

-

-

... More
Metering Pumps, Max. Flow: 4LPH, Max. Injection Pressure: 5.5kg/cm2, PP Liquidend, with accessories like foot valve, strainer, injection valve, antisyphon valve.

-

-

-

... More
PE Storage Tank, 60lts, lid with facility to mount the metering pump

-

-

-

... More
LDPE Tubing from Dosing Pump to Sampling Line Dosing Point

-

-

-

... More
Conductivity Control System with following components

-

-

-

... More
a. Conductivity Sensor; Wetted materials – PVC b. Electrodes – SS c. Conductivity Transmitter, Power: 24V DC ; Output: 4-20mA Blowdown Control Valve, 2” Size, Antiscalant Dosing System with following components: Metering Pumps, Max. Flow: 4LPH, Max. Injection Pressure: 5.5kg/cm2, PP Liquidend, with accessories like foot valve, strainer, injection valve, antisyphon valve. PE Storage Tank, 60lts, lid with facility to mount the metering pump LDPE Tubing from Dosing Pump to Sampling Line Dosing Point. Non – Oxidising Biocide Dosing System with following components: Metering Pumps, Max. Flow: 4LPH, Max. Injection Pressure: 5.5kg/cm2, PP Liquidend, with accessories like foot valve, strainer, injection valve, antisyphon valve. PE Storage Tank, 60lts, lid with facility to mount the metering pump LDPE Tubing from Dosing Pump to Sampling Line Dosing Point.Bio-Dispersant Dosing System with following components: Metering Pumps, Max. Flow: 4LPH, Max. Injection Pressure: 5.5kg/cm2, PP Liquidend, with accessories like foot valve, strainer, injection valve, antisyphon valve. PE Storage Tank, 60lts, lid with facility to mount the metering pump LDPE Tubing from Dosing Pump to Sampling Line Dosing Point.Corrosion Inhibitor Dosing System with following components: Metering Pumps, Max. Flow: 4LPH, Max. Injection Pressure: 5.5kg/cm2, PP Liquidend, with accessories like foot valve, strainer, injection valve, antisyphon valve. PE Storage Tank, 60lts, lid with facility to mount the metering pump LDPE Tubing from Dosing Pump to Sampling Line Dosing Point.Electrical Control Panel comprising of Controller with RS 485 Port Safety Circuits and Terminals for cable connections.

-

-

-

... More
Control Skid To house the above mentioned items along with required piping and internal cabling

1

-

-

... More
COOLING TOWER CIRCUIT & CHILLED WATER CIRCUIT DOSING SYSTEM

-

-

-

... More
Pre-Cleaning & Passivation with chemicals For open loop

5

-

-

... More
Surfactant clenaing with VOD 10

20

-

-

... More
Bioflushing with BIONIL 9120

35

-

-

... More
Low pH clenaing with SCALNOR

85

-

-

... More
Passivation with CORROCIL 9330

35

-

-

... More
Service charges

1

-

-

... More
Regular treatment for open loop system (quantities are for 1 year)

-

-

-

... More
For open loop

5

-

-

... More
Phosphanate based anti scalent SCACIL 9800

900

-

-

... More
Corrosion inhibitor CORROCIL 9330

150

-

-

... More
Bio-dispersant SCACIL 9010

75

-

-

... More
Oxydizing chloro bromin based biocide

120

-

-

... More
Non-oxidizing isothozilin based biocide BIONIL 9120

200

-

-

... More
PH corrector- 98% concentration H2SO4

1600

-

-

... More
LOWDISE DUCTING WORKS

-

-

-

... More
SHEET METAL DUCTING Supply, installation balacing and commissoning of factroy fabricated GSS sheet metel rectangular/ round duct complete with neoprene rubber gaskets, elbows, spliter dampers, vanes, hangers suppots, etc. As per approved drawings and specifications of follwing sheet thickness complete as required.Duct pressure test to be considered (0-500 Psi) with nessarry supporting materials part of this item (Vendor need to be submit detailed report before appling insulationThird party air balancing to be considered part of this item.

-

-

-

... More
0.63 MM ( With Ductmate Flanges)

3200

-

-

... More
0.8 MM ( With Ductmate Flanges)

1800

-

-

... More
1.0 MM ( With Ductmate Flanges)

1200

-

-

... More
1.25 MM (With Ductmate Flanges)

750

-

-

... More
Supply and installations of factory made Powder coated sheet metal Flat oval Spiral ducting with (factory made internal thermal insulation -9 mm thick closed cell material to be considered cost of this shall be inclusive of this item) fittings, Wire supports, The factor of wire to suit to duct weight, with necessary anchor fasteners and hook arrangements with suitable rod thickness,etc., confirming SMACNA standards. Duct should be fabricated by using CNC machines, Including necessary civil works as per site condition. Exposed ducts color to match interior requirement. Colour shall be confirmed by Architect. The joints shall be 100% leak proof. The duct should be factory made internally insulated with 9mm thick antimicrobial nitrile rubber. (Light test need to considered for elliptical ducts)

-

-

-

... More
24 G ( With Ductmate Flanges)

200

-

-

... More
22 G ( With Ductmate Flanges)

250

-

-

... More
20 G (With Ductmate Flanges)

250

-

-

... More
18 G (With Ductmate Flanges)

150

-

-

... More
LOWDISE AIRTERMINAL WORKS

-

-

-

... More
Double Skin plenum Supply and installations of 25 thick double skin plenum along with nessarry supporting meaterial

50

-

-

... More
AIR TERMINAL DEVICES Supply, fixing testing commissioning of Return air diffusers of powder coated aluminium without volume control dampers with anti smudge ring and removable core.

50

-

-

... More
Supply and installation of Powder coated extruded aluminium continuous linear grilles as per specifications. The rate shall inclusive without collar damper, necessary fixing and supporting arrangement for the grilles

200

-

-

... More
Supply and installations of Powder Coated Curved grilles with collar damper for supply distribution in Oval duct ( colour for the grill to b confirmed by Arch/ PMC team before placing the order) . Deflection of the grille shall be 0 / 15 / 30. same will be confirmed later.

40

-

-

... More
Supply, installation of Collar Dampers of opposed blade type made out of Aluminium alloy extrusion with anodised matt black finish (quantity including for diffusers & grills)

50

-

-

... More
Supply, installation of Fresh air / Exhaust Louvers with bird wire mesh

45

-

-

... More
Supply and installation of Powder coated extruded aluminium Disc Valve of the following diameter for exhaust air. The rate shall be inclusive of volume control damper and necessary fixing and supporting arrangement for the valve. Size: 150mm Dia neck

336

-

-

... More
4 / 2 Way Square Diffusers Powder coated, extruded aluminium, removable center core type, supply / return air diffusers without volume control dampers of aluminium construction of the following neck sizes. The diffuser shall be mounted in the GI box ( in scope), with inlet connector suitable for flexible duct. GI Box & Flexible duct quantified seperately. The diffuser can be either 4-way / 2-Way based on decision which shall be taken at a later date - Without Neck Damper. Measurement shall be based on outer to outer size of the air terminal device

100

-

-

... More
Supply, installation of JET NOZZLES for supply air distribution - adjustable type

-

-

-

... More
350 mm dia

30

-

-

... More
300 mm dia

20

-

-

... More
250 mm dia

15

-

-

... More
Supply, installation of Insulated Flexible Ducting Factory Fabricated Insulated Flexible made out aluminium for connecting from main duct to diffuser box. The length of the flexible duct shall be around 1.0 to 1.8 mtr. The flexible duct shall me made of triple lamination of aluminium foil, polyester and metalised polyester film permanently bonded to a coated spring steel wire helix. The exterior shal be wrapped with 25mm thick 16 kg / cum fibreglass insulation. The outer insulation jacket / vapour barrier made of fibreglass reinforced metalised polyester film laminate.

-

-

-

... More
150 mm dia

504

-

-

... More
250 mm dia

100

-

-

... More
300 mm dia

30

-

-

... More
Supply installations of Butterfly Dampers made out of 20G GI sheets similar duct specifications

-

-

-

... More
150mm dia

336

-

-

... More
200 mm dia

10

-

-

... More
250mm dia

150

-

-

... More
300mm dia

45

-

-

... More
Supply and installations of low leakage Volume Control Dampers with TDF flanges having Square slot for Carriage Bolt fixing suitable for connecting to the ducts on both sides. Completely factory - made, 1.6 mm thick opposed blade GSS interlocking blades, 1.6 mm thick GSS frame, High quality plastic bushes, Embossed Lettering on Handle plate for Blade open level indication. The pressure drop across the dampers shall not exceed 1.5 mm of wg at 1500 fpm for the cross section area of 1 sqm.

50

-

-

... More
Supply, installation, testing and balancing of GSS OVAL shape Volume Control Dampers all dampers should of robust construction with multi opposed blade construction of low leakage type. The outer casing shall be made out of 1.6mm.thick GI welded frame with flat type 1.6mm with operating handle for Supply air duct branches in accordance with the approved shop drawings.

10

-

-

... More
Supply, installation, testing and balancing of Pressure Relief Dampers made out of 1.6 mm thick galvanized sheet steel frame and blades of 1.6 mm galvanised sheet steel with linkages capable of maintaining constant pressure at various airflows & close upon decrease in differential pressure. The damper shall be designed to provide pressure relief at 50 Pascals & 15 m/s velocity.

5

-

-

... More
Supply and installations Motorised On/off type volume Control Dampers made out of 100 x 40 x 1.55 mm thick galavanised steel frame and blades of 1.55 mm galavanised sheet steel

6

-

-

... More
Supply & installation of spring return type damper actuator with control panel along with BMS compatability for switch On/Off, Torque to be selected based on Damper size in NM.

10

-

-

... More
Supply and installations Motorized Modulating type low leakage air dampers made out of 100x40x1.55mm thick galvanised steel frame & blade for fresh air modulation with actuator complete with all accessories like Actuator,control panel etc and any necessary requirement which can perform the controlling the Damper. It shall be integrated with Co2 sensor and based on CO2 levels, damper shall be modulate. (Co2 sensor provided by BMS scope). The damper shall be set at minimum 100 % fresh air supply and it shall modulate from 100 to 130 % fresh air supply as per the signals recieved from the CO2 sensor.

38

-

-

... More
Supply and installations testing & commissioning of actuator with control panel should be compatible for third party BMS integration .necessary fire integrator should be consider in part HVAC vendor scope

80

-

-

... More
Supply,installation,testing & comissioning of 525 x 525 x 450 mm High Sheet Metal Spill air boxes made out of 26 GI sheet for connecting the diffuser outlet & flexible connection from the main duct. Plenum box shall be internally insulated with 6mm thick class O closed cell nitrile rubber insulation. Cost of insulation shall be included is this item only. Spill air boxes shall be constructed with Cross mark grooves for additional stability

5

-

-

... More
Supply,installation,testing & comissioning of 1000 x 150 x 450 mm High Sheet Metal Spill air boxes made out of 26 GI sheet for connecting the diffuser outlet & flexible connection from the main duct. Plenum box shall be internally insulated with 6mm thick class O closed cell nitrile rubber insulation. Cost of insulation shall be included is this item only. Spill air boxes shall be constructed with Cross mark grooves for additional stability

5

-

-

... More
Fire Damper

-

-

-

... More
Supply, installation, testing and commissioning of UL555 Listed and certified classified dynamic rated combination fire smoke damper. Damper shall be Multi-blade type damper with 180 minutes fire rating. Damper construction shall include 16 gauge galvanized steel frames and blades, Resettable resuable link, SS jamb seals and axle bearings, Silicon blade seals, steel axle. Blade type shall be 3V or Airfoil type. UL 555S Leakage Rating Leakage Class: I All dampers shall bear the AMCA Certified Ratings Program seal for Air Performance.

45

-

-

... More
Supply and installations of Actuators for above fire dampers- HIGH TORQUE TYPE-10 NM.

50

-

-

... More
Supply and installations of Actuators for fire dampers- MEDIUM TORQUE TYPE 5 NM.

10

-

-

... More
AHU room - Fire damper control panel with Modbus over RS485 output for BMS compatibility. Each panel shall be located in AHU room and shall control 4 to 6 fire dampers. It should take one fire input and from the FD panel, output to be provided to trip the dampers, AHU & TFA. (If the fire damper panel is off then AHU & TFA should not turn ON). - This shall be BMS compatible with Modbus over RS485 output

10

-

-

... More
UPS & Server Room- Fire damper control panel with Modbus over RS485 output for BMS compatibility. Each panel shall be located in UPS room and shall control 3 or 5 fire dampers. It should take one fire input and from the FD panel, output need to provided to trip the dampers - This shall be BMS compatible with Modbus over RS485 output

4

-

-

... More
Supply, installation, testing and commissioning of Fusible link type Fire Damper of 180 minutes fire resistant complete with all standard accessories. Fire damper as per UL 555-S, outer shell constructed with 1.6mm thick galvanized steel frame and the blade/Leaf with 1.6mm thick GSS in accordance with the GFC/ shop drawings

4

-

-

... More
Supply, laying, testing & commissioning of MS insulated MS sheathed, steel armoured ,aluminium conductors 1100 V grade power cables. The cables shall be laid in tray built up trench etc., Rate shall exclude the cost of tray. '3 runs of 2.5 sq.mm HFLS Cu Wire in 19 mm dia MS Conduit for damper panel to Fire dampers

350

-

-

... More
Canvas connection : Supply, installation of Heavy duty double layered Canvas connection consisting of a flame retardnat fabric secured between galvanized sheet metal on either side by a double lock seam inserted between the equipment / Duct to provide wear resistant air tight flexible connection to eliminat vibrations, noise and rattles with fire rating EN532 and 533

29

-

-

... More
Supply, installation of Uninsulated Flexible duct - 150 mm dia for toilet disc valve connection

510

-

-

... More
Supply, installation of Back Draft Dampers made out of 100 x 40 x 1.55 mm thick galvanised steel frame and blades of 1.55 mm galvanised sheet steel

47

-

-

... More
LOWSIDE DUCT INSULATION MATERIALS

-

-

-

... More
Supply and installation of (Accoustic) Duct liner (Insulation) of specified thickness of Elastromeric Rubber Insulation manafactured as per ASTM E 84 test & which should also meet NFPA 90A supplementary materials for air distribution system which should not absorbs less 0.2% water by volume (ASTM c 209), should not support microbial growth (ASTM C1071, G21, G22) and should emit objectionable odors (ASTM C 665) and should have thermal conductivity of 0.27 ( R - 2.78 in 3.4" thickness) and water vapor permeance of 0.10. - Class "1" Material-.All joints of the Insulation material should be further covered with 50 mm wide 3 mm thick self adhesive tape made of similar material & Black Cotton Tape shall not be used. 15mm Thick

3500

-

-

... More
Supply and installation Thermal (Insulation) of specified thickness of Elastomeric Rubber Insulation manufactured as per ASTM E 84 test & which should also meet NFPA 90A supplementary materials for air distribution system which should not absorbs less 0.2% water by volume (ASTM c 209), should not support microbial growth (ASTM C1071, G21, G22) and should emit objectionable odors (ASTM C 665) and should have thermal conductivity of 0.27 ( R - 2.78 in 3.4" thickness) and water vapor permeance of 0.10. Joints should be sealed with 100 mm wide 3mm thick self adhesive tape (Black Cotton Tape not acceptable). Class "O" Material-Material should be FM approved. For internal ducts ,insulation should be provided without any patches . For under deck insulation, surface should be dust free .One coat adhesive to be provide on surface & material should be provided. 9mm Thick

5000

-

-

... More
Supply and installation Thermal (Insulation) of specified thickness of Elastomeric Rubber Insulation manufactured as per ASTM E 84 test & which should also meet NFPA 90A supplementary materials for air distribution system which should not absorbs less 0.2% water by volume (ASTM c 209), should not support microbial growth (ASTM C1071, G21, G22) and should emit objectionable odors (ASTM C 665) and should have thermal conductivity of 0.27 ( R - 2.78 in 3.4" thickness) and water vapor permeance of 0.10. Joints should be sealed with 100 mm wide 3mm thick self adhesive tape (Black Cotton Tape not acceptable). Class "O" Material-Material should be FM approved. For internal ducts ,insulation should be provided without any patches . For under deck insulation, surface should be dust free .One coat adhesive to be provide on surface & material should be provided. 13mm Thick

1300

-

-

... More
Supply and erection of Thermal Insulation with Protection against UV / Mechanical damage of exposed duct. The insulation shall be closed cell nitrile rubber with treated woven glass fibre covering. Rate shall inclusive of Two coats of synthetic enamel weather proof paint shall be applied over the insulation and the adhesive as per manufacturers recommendation. 19mm thickness of the insulation.

500

-

-

... More
Supply and erection of Thermal Insulation with Protection against UV / Mechanical damage of exposed duct. The insulation shall be closed cell nitrile rubber with treated woven glass fibre covering. Rate shall inclusive of Two coats of synthetic enamel weather proof paint shall be applied over the insulation and the adhesive as per manufacturers recommendation. 25mm thickness of the insulation.

2500

-

-

... More
SITC of underdeck insulation for all AC areas exposed to directly Sun shall be provided with 50 mm thick TF quality Expanded Polystyrene slab or material of equivalent u value. The material shall be conform to IS:4671 & shall be of type ‘N’ unless specified otherwise. The apparent density shall be of 24 Kg/m³. The thickness of the material to be of 50mm. The vendor to include the cost of all material related to installation of the same for the top slab level with cleaning and making surface dust free, applying adhesive and providing 600x600 mm wire mesh grid with 26 G GI wire along with EPS slabs pasting on the surface. Vendor to ensure the installation as per engineer IN charges satisfaction.

10

-

-

... More
Supplying ,fixing acoustic lining on wall and ceiling of AHU/ Chiller Plant room with 50mm thick density 32kg/cu.m resin bonded glass fiber insullation friction fixed in 610mmx610mm frame work made of 25x50x50x50x25mm made out of 0.6mm thick GI sheet U shaped channel and covered with reinforced fiber glass tissue and finished with 0.8mm perforated alumimuim sheet etc. complete as required as per specification

1000

-

-

... More
Kitchen exhaust ducting and accessories

-

-

-

... More
MS Ducting - SS304 grade material 16 G with complete joints, & MS supports at every 1.5 mts capable of taking 600 kgs point load - Floor,Shaft & Terrace Area. Necessary scafollding required for erecting above within the shafts from 16th floor to terrace should be considered in the scope of works. Fire rated gasket material to be used for duct joining. Mockup to be provided for the duct support arrangement along with duct joints before going ahead.

400

-

-

... More
Grease Collection Box near the unit. Construction of Grease Collection Box should be similar to same as Ducting specified above

2

-

-

... More
20 Inches x 20 Inches Trap Door fabricated of same material / specs as Ducting specified above. Acess panel shall have a gasket which can sustain 1500 deg F (815 deg C) temperature. Same need to be located in the kitchen area, shafts , units etc

2

-

-

... More
Volume control Damper made out of MS material (higher than ducting material) for air balancing. Frame: High quality Stainless Steel sheet (Grade 304/316L) of thickness 16 G depending on size Frame shall be made of 125mm depth and standard flange height of 25mm. Blades shall be single skin ridge shaped blade constructed out of 16G thick S.S sheet as standard.

5

-

-

... More
Pressure relief damper for kitchen exhaust duct. In case of pressure build up in the kitchen, the damper shall release the pressure to the atmosphere. Needs to fixed on the exhaust duct near the exhaust fan with all accessories, supports, etc. Shall be made of 16 G GI of the following sizes.

1

-

-

... More
MS duct insulation with Al. Foil faced fibre glass wool 25 mm thick, 32 kg /m3 density

600

-

-

... More
VENTILATION WORKS

-

-

-

... More
Supply installation testing & commissioning of Fire Rated Tube axial exhaust Fan with motor including casing made of Hot dipped Galvanized Iron, motor, with adjustable pitch die cast aluminium impeller (Hub and blades) Casing position shall be as per the job requirement and shall be marked on the fan assembly of the following capacities. Note: The Fan assemble along with motors should be tested for Temperature range: 300 deg C/2Hours for Smoke Evacuation.Cost inclusive of proposed fan motor suitable KW Starter panel for exhaust fan with allother associated accessories as required as per the site conditions with 2NO + 2NC potential free contacts, connectors, contactors with wiring etc are to be provided for ON /OFF & indication for ON OFF & TRIP to be provided. (IE-4 Motor)

-

-

-

... More
16000Cfm,40mm ESP - Smoke Extraction ( For Atrium)

8

-

-

... More
Supply installation testing & commissioning Ductable axial flow units incorporated with/without sound attenuators , flow straighteners according to the type, bird screen and cowl and suitable for outdoor installation and mounted on a steel frame work with vibration isolation cushy foot mountings of following capacitie.Cost inclusive of proposed fan motor suitable KW Starter panel for exhaust fan with allother associated accessories as required as per the site conditions with 2NO + 2NC potential free contacts, connectors, contactors with wiring etc are to be provided for ON /OFF & indication for ON OFF & TRIP to be provided. (IE-4 Motor)

-

-

-

... More
16500Cfm, 25mm ESP - Stairwell

4

-

-

... More
10500Cfm, 25mm ESP - Service Lift Lobby

2

-

-

... More
24000Cfm, 25mm ESP - Lift Well

4

-

-

... More
5500Cfm, 25mm ESP, Noise level of the fan should be less than 65dba@3M distance- Electrical Room Exhaust (With attenuator)

3

-

-

... More
20000Cfm, 25mm ESP Noise level of the fan should be less than 65dba@3M distance- STP & Pump Room Exhaust (With attenuator)

3

-

-

... More
7500Cfm, 25mm ESP Noise level of the fan should be less than 65dba@3M distance- Plant Room Exhaust (With attenuator)

2

-

-

... More
Supply, Installation, Testing and Commissioning of Double skin cabinet type, inner skin and outer skin shall be minimum 1 mm thick pre-coated and pre plasticized sheets, Puff panel of 25 mm(+/-1mm) thickness, density of insulation shall be 48 Kg/sq.m, DIDW/SISW backward curve fan with motor shall be IE 4 type fan motor to suitable for VFD to rampup & ramp down the motor speed, (VFD in seperate line item) Fan total efficiency shall be minimum 75%, unit base with suitable size of coushy foot mounting, Motor winding shall be vacuum pressure impregnated for all motors. Insulated bearing on non-drive end for Motor frame of 315 and above shall be provided. fans are rated and tested in accordance with AMCA standard to meet the air and sound performance requirements, Selected Motor rating shall be minimum 15% above BKW.Cost inculde at site perfromance test with OEM Engineer. Weather proof canopy should be provided for all units located on terrace. An extended canopy of 150 mm all around the unit to be considered.Cost inclusive of proposed fan motor suitable KW starter panel with DOL/Star-Delta starter and BMS compatible Variable Frequency Drive with controller with auto bye pass arrangement. The VFD shall have Frequency controller, Microprocessor based logic controller, integrated Software capable to control frequency based on the inputs from sensors, power cable from VFD to AHU, communication cable, Communication card (BACnet protocol) to transfer the entire data available on VFD to the third party BMS System. The VFD shall have IP-20 protection and panel shall have IP65 protection. (Outdoor mount type) - (IE-4 Motor)

-

-

-

... More
Capacity of 9000 cfm Exhaust air unit- ESP 60mm Toilet Exhaust (DIDW Fans)

8

-

-

... More
Capacity of 10000 cfm Exhaust air unit- ESP 60mm Electrical room Exhaust (DIDW Fans)

2

-

-

... More
Capacity of 7000 cfm Exhaust air unit- ESP 125mm WITH SISW backward curved fan Kitchen Exhaust. Fan motor shall be outside the air stream.

2

-

-

... More
Capacity of 2750 cfm Exhaust air unit- ESP 40mm General Exhaust (DIDW Fans)

2

-

-

... More
Capacity of 5000 cfm Exhaust air unit- ESP 25mm with 10Micron Prefilter for Electrica; Room Fresh air (DIDW Fans). Fan shall be ceiling suspended type

2

-

-

... More
Capacity of 17000 cfm Exhaust air unit- ESP 25mm with 10Micron Prefilter for STP & Pump Room Fresh air (DIDW Fans). Fan shall be ceiling suspended type

3

-

-

... More
Outdoor mount Dry Scubber (7000 CFM each). The Scrubber shall be Electrostatic precipitation technology based dry type air cleaner to remove oil, smoke & fumes from the Kitchen exhaust air. Unit shall be made of 18 gauge galvanized sheet, high bake epoxy powder coated. having prefilter, tungsten wire ionizers & collector plates and having a average effeciency of 90% to 95%. The control panel must have provision for auto restart in case of power failure, short circuit arc protection with automatic power restoration to prevent overloading & 'NO' potential free contact for monitoring on BMS system. The units must be selected to not exceed face velocity of 550 FPM & must have passed third party ASHRAE testing for similar capacities. MS angle supports to be considered for supporting the dry scrubbers on the terrace. vertical stacking arrangement to be considered to locate 3 nos of dry scrubbers one above the other.

2

-

-

... More
DUCT MOUNTED RECTANGULAR IN LINE FAN UNIT:

-

-

-

... More
All sheet metal Double Skin Rectangular In Line Centrifugal Fans fabricated out of 1 mm thick Galvanized Steel for use as Exhaust/Outside Air or fresh air Unit. The unit shall be complete with flanged connection on either side, fixing bracket, fan motor assembly, power cabling with required plug of around 5m length from the unit to power socket provided by other agencies etc.. suitable for operation through on 220 V, 1 Ph, 50 Hz AC supply.The noise from Inline Fan shall not exceed 50 dbA.The cost of the Inline Fan also includes DOL Starter with On/off push button staton, A/M Status and PF/relays etc for BMs integration and along with inbuilt fan regulator.

-

-

-

... More
300 Cfm exhaust fan - 10 mm external static Inline fan with all necessary supports. Unit shall be provided along with fire retardant flexible canvass with Zip, Cowl piece with bird mesh and supporting arrangements.

1

-

-

... More
200 Cfm exhaust fan - 10 mm external static Inline fan with all necessary supports. Unit shall be provided along with fire retardant flexible canvass with Zip, Cowl piece with bird mesh and supporting arrangements.

1

-

-

... More
1200 Cfm toilet exhaust fan - 20 mm external static Inline fan with all necessary supports. Unit shall be provided along with fire retardant flexible canvass with Zip, Cowl piece with bird mesh and supporting arrangements.

48

-

-

... More
800 Cfm battery exhaust fan - 20 mm external static Inline fan with all necessary supports. Unit shall be provided along with fire retardant flexible canvass with Zip, Cowl piece with bird mesh and supporting arrangements.

1

-

-

... More
Supply fixing testing & commissioning of Hyderagen sensor with sequential timer suitable control panel to operate Battery room exhaust fan at regular 2hrs interval fan run 5.0 minutes and when increse the Hyderagen level above 1% switch ON the fan. Controller shall have bypass mode to switch ON / OFF manually with necessary control wiring. panel shall provided with BMS compartability via Modbus over RS485.

1

-

-

... More
1800 Cfm exhaust fan - 20 mm external static Inline fan with all necessary supports. Unit shall be provided along with fire retardant flexible canvass with Zip, Cowl piece with bird mesh and supporting arrangements.

1

-

-

... More
250 Cfm fresh air fan with inbuilt MERV-8 & MERV-13 filters and 25 mm external static Inline fan with all necessary supports. Unit shall be provided along with fire retardant flexible canvass with Zip, Cowl piece with bird mesh and supporting arrangements.

1

-

-

... More
600 Cfm fresh air fan with inbuilt MERV-8 & MERV-13 filters and 25 mm external static Inline fan with all necessary supports. Unit shall be provided along with fire retardant flexible canvass with Zip, Cowl piece with bird mesh and supporting arrangements.

1

-

-

... More
Treated Fresh air unit

-

-

-

... More
Supply, installation testing & commissioning EUROVENT CERTIFIED Floor mounted Treated fresh air units having following specifications. Frame Structure consisting of 45mm Extruded Aluminium Thermal break profile: Capacity Panel: 45mm +/- 2mm thick double skin sandwich panels with Rockwool insulation of density 60 kg/cum , The sheet thickness shall be minimum 0.8 mm for the outer skin and 0.8 mm thickness for the inner skin of GI . with Plenum box for fresh air intake. Filtration Section shall be provided with 2 stage washable type of 'MERV8 ' first stage and 'MERV14' final stage. Coil Section: Chilled water coil Minimum 8 row deep constructed with Aluminium fins of minimum 0.11mm thickness and copper tubes of minimum 29Guage thickness. Copper tube shall be 9.6mm or 12.5mm diameter. The coil face area shall not exceed 2.5m/sec. Coil Section is Equipped with Factory Fitted Energy Valve / PIBV , UV Lamp considered along with the unit. Drain Pan: Condensate drain pan shall be fabricated from 20 G SS 304 powder coated, insulated with 19 mm thick closed cell elastomeric insulation. Fan Section: Direct drive backward curved EC fan ( Electronically commutated ) with permanent magnet brushless DC motor for stepless variation of speed of fan based on temperature sensor inputs. The fan section shall be provided with limt switch for safety to shut off fan during Opening of access door. Electrical starter Panel with Auto /Manual switch and incomer power terminal along with provision for fire damper on/ off withinAHU room. Instrumentation Kit to be provided to give out the following option.

-

-

-

... More
95 TR /17050 CFM with 40mm ESP ( Office Area Fresh air)

1

-

-

... More
Supply, installation testing & commissioning EUROVENT CERTIFIED Floor mounted Treated fresh air units having following specifications. Frame Structure consisting of 45mm Extruded Aluminium Thermal break profile: Capacity Panel: 45mm +/- 2mm thick double skin sandwich panels with Rockwool insulation of density 60 kg/cum , The sheet thickness shall be minimum 0.8 mm for the outer skin and 0.8 mm thickness for the inner skin of GI . with Plenum box for fresh air intake. Filtration Section shall be provided with 2 stage washable type of 'MERV8 ' first stage and 'MERV14' final stage. Coil Section: Chilled water coil Minimum 8 row deep constructed with Aluminium fins of minimum 0.11mm thickness and copper tubes of minimum 29Guage thickness. Copper tube shall be 9.6mm or 12.5mm diameter. The coil face area shall not exceed 2.5m/sec. Coil Section is Equipped with Factory Fitted Energy Valve / PIBV , UV Lamp considered along with the unit. Drain Pan: Condensate drain pan shall be fabricated from 20 G SS 304 powder coated, insulated with 19 mm thick closed cell elastomeric insulation. Fan Section: Direct drive backward curved EC fan ( Electronically commutated ) with permanent magnet brushless DC motor for stepless variation of speed of fan based on temperature sensor inputs. The fan section shall be provided with limt switch for safety to shut off fan during Opening of access door. Electrical starter Panel with Auto /Manual switch and incomer power terminal along with provision for fire damper on/ off withinAHU room. Instrumentation Kit to be provided to give out the following option.

-

-

-

... More
68TR /12150CFM with 65mm ESP ( Office Area Fresh air)

2

-

-

... More
Supply, installation testing & commissioning EUROVENT CERTIFIED Floor mounted Treated fresh air units having following specifications. Frame Structure consisting of 45mm Extruded Aluminium Thermal break profile: Capacity Panel: 45mm +/- 2mm thick double skin sandwich panels with Rockwool insulation of density 60 kg/cum , The sheet thickness shall be minimum 0.8 mm for the outer skin and 0.8 mm thickness for the inner skin of GI . with Plenum box for fresh air intake. Filtration Section shall be provided with 2 stage washable type of 'MERV8 ' first stage and 'MERV14' final stage. Coil Section: Chilled water coil Minimum 8 row deep constructed with Aluminium fins of minimum 0.11mm thickness and copper tubes of minimum 29Guage thickness. Copper tube shall be 9.6mm or 12.5mm diameter. The coil face area shall not exceed 2.5m/sec. Coil Section is Equipped with Factory Fitted Energy Valve / PIBV , UV Lamp considered along with the unit. Drain Pan: Condensate drain pan shall be fabricated from 20 G SS 304 powder coated, insulated with 19 mm thick closed cell elastomeric insulation. Fan Section: Direct drive backward curved EC fan ( Electronically commutated ) with permanent magnet brushless DC motor for stepless variation of speed of fan based on temperature sensor inputs. The fan section shall be provided with limt switch for safety to shut off fan during Opening of access door. Electrical starter Panel with Auto /Manual switch and incomer power terminal along with provision for fire damper on/ off withinAHU room. Instrumentation Kit to be provided to give out the following option.

-

-

-

... More
54TR / 9650CFM with 65mm ESP ( Office Area Fresh air)

2

-

-

... More
Supply, installation testing & commissioning EUROVENT CERTIFIED Floor mounted Treated fresh air units having following specifications. Frame Structure consisting of 45mm Extruded Aluminium Thermal break profile: Capacity Panel: 45mm +/- 2mm thick double skin sandwich panels with Rockwool insulation of density 60 kg/cum , The sheet thickness shall be minimum 0.8 mm for the outer skin and 0.8 mm thickness for the inner skin of GI . with Plenum box for fresh air intake. Filtration Section shall be provided with 2 stage washable type of 'MERV8 ' first stage and 'MERV14' final stage. Coil Section: Chilled water coil Minimum 8 row deep constructed with Aluminium fins of minimum 0.11mm thickness and copper tubes of minimum 29Guage thickness. Copper tube shall be 9.6mm or 12.5mm diameter. The coil face area shall not exceed 2.5m/sec. Coil Section is Equipped with Factory Fitted Energy Valve / PIBV , UV Lamp considered along with the unit. Drain Pan: Condensate drain pan shall be fabricated from 20 G SS 304 powder coated, insulated with 19 mm thick closed cell elastomeric insulation. Fan Section: Direct drive backward curved EC fan ( Electronically commutated ) with permanent magnet brushless DC motor for stepless variation of speed of fan based on temperature sensor inputs. The fan section shall be provided with limt switch for safety to shut off fan during Opening of access door. Electrical starter Panel with Auto /Manual switch and incomer power terminal along with provision for fire damper on/ off withinAHU room. Instrumentation Kit to be provided to give out the following option.

-

-

-

... More
38TR/6850CFM with 65mm ESP ( Office Area Fresh air)

4

-

-

... More
Supply, installation testing & commissioning EUROVENT CERTIFIED Floor mounted Treated fresh air units having following specifications. Frame Structure consisting of 45mm Extruded Aluminium Thermal break profile: Capacity Panel: 45mm +/- 2mm thick double skin sandwich panels with Rockwool insulation of density 60 kg/cum , The sheet thickness shall be minimum 0.8 mm for the outer skin and 0.8 mm thickness for the inner skin of GI . with Plenum box for fresh air intake. Filtration Section shall be provided with 2 stage washable type of 'MERV8 ' first stage and 'MERV14' final stage. Coil Section: Chilled water coil Minimum 8 row deep constructed with Aluminium fins of minimum 0.11mm thickness and copper tubes of minimum 29Guage thickness. Copper tube shall be 9.6mm or 12.5mm diameter. The coil face area shall not exceed 2.5m/sec. Coil Section is Equipped with Factory Fitted Energy Valve / PIBV , UV Lamp considered along with the unit. Drain Pan: Condensate drain pan shall be fabricated from 20 G SS 304 powder coated, insulated with 19 mm thick closed cell elastomeric insulation. Fan Section: Direct drive backward curved EC fan ( Electronically commutated ) with permanent magnet brushless DC motor for stepless variation of speed of fan based on temperature sensor inputs. The fan section shall be provided with limt switch for safety to shut off fan during Opening of access door. Electrical starter Panel with Auto /Manual switch and incomer power terminal along with provision for fire damper on/ off withinAHU room. Instrumentation Kit to be provided to give out the following option.

-

-

-

... More
32TR/5600CFM with 65mm ESP ( Office Area & Kitchen area Fresh air)

2

-

-

... More
Supply, installation, testing and commissioing of Suitable IP55 VFD & PID controller (A0-2.Ai-4, DO-5,DI -5) with by pass star delta starter for operation of Ahus Supply air fan, auto/manual switch, saftey switch, ammeter, voltmer and energy meter, disconnet switch VFD/star delta units shall be provided with factory fitted Active Harmonic Filters meeting IEEE 519 standards and THDI not exceeding 5%, panel shall be as per the IS standard of electrial standard and, CRCA-14 G / 2mm thick Sheet steel enclosed, indoor floor mounted free standing cubicle type & CNC fabricated, required BMS compatable for the above operation.

1

-

-

... More
Supply, installation, testing and commissioing of suitable fire rated Double compression cable gland for the above both the end termination

650

-

-

... More
Supply, installation, testing and commissioing of Emergency Lockable Push button station for the above, Fire rated type with required GI angle iron support

15

-

-

... More
Supply, installation, testing and commissioing of Emergency Lockable Push button station cabling for the above, 3 core 1.5 square XLPE copper armoud fire rated cable length shall be 20rmt between motor to Push button

150

-

-

... More
Supply, installation, testing and commissioing of MS channel support with two coat of enamal painting for Unit supports, Support shall be with cushy foot mounting or spring mounting as per the manufacter standard Extra supports otherthan installation drawing. Consider this line item.

1000

-

-

... More
Supply, installation and commissioning of Air curtains suitable for 230V/50Hz/AC power supply complete with aluminimum centrifugal flow fans wheel and double shaft motors, heavy duty to suit the following sizes of Rolling shutter/Door for dust barrier and for a minimum inside temperature of 29ºC internal barrier and noise level should not exceed more than 55dB (A). 6 feet length, Air Flow: 1300 m3/hr, Air Velocity : 21-25 m/s ; Noise level 60DB for (Door Ht. - 3.5 mtrs.)

4

-

-

... More
Supply, installation and commissioning of Air curtains suitable for 230V/50Hz/AC power supply complete with aluminimum centrifugal flow fans wheel and double shaft motors, heavy duty to suit the following sizes of Rolling shutter/Door for dust barrier and for a minimum inside temperature of 29ºC internal barrier and noise level should not exceed more than 55dB (A). 4 feet length, Air Flow: 1300 m3/hr, Air Velocity : 21-25 m/s ; Noise level 60DB for (Door Ht. - 3.5 mtrs.)

4

-

-

... More
LT CABLES & END TERMINATIONS

-

-

-

... More
Supply, laying, testing & commissioning of the following sizes of 1.1KV grade Copper Conductor armoured power cables Insulation of XLPE above 25Sqmm and Class A PVC below 25Sqmm laid on trays, ceilings, walls trenches, ground etc., with necessary clamps, cable ties, fasteners, identification tags, cable marking as required. Cost of sand, bricks, excavation should not be included in the rate quoted & measured separately.

-

-

-

... More
1C X 185 sqmm Copper flexible cable

1200

-

-

... More
1C X 150 sqmm Copper flexible cable

500

-

-

... More
1C X120 sqmm Copper flexible cable

10

-

-

... More
1C X95 sqmm Copper flexible cable

10

-

-

... More
1C X 25 sqmm Copper flexible cable

500

-

-

... More
1C X 16 sqmm Copper flexible cable

500

-

-

... More
1C X 10sqmm Copper flexible cable

500

-

-

... More
1C X 6sqmm Copper flexible cable

120

-

-

... More
4CX16sq.mm 2XWY

50

-

-

... More
4CX10sq.mm 2XWY

50

-

-

... More
4CX6sq.mm 2XWY

50

-

-

... More
Supply & end termination of following CU armoured power cables with necessary double compression brass glands, CU. terminal sockets, insulation tapes, fasteners, earthing clips & connecting the clip to main earth bus with suitable bare copper wire complete accessories as required; all outdoor double compression and indoor single compression

-

-

-

... More
1C X 185 sqmm Copper flexible cable

85

-

-

... More
1C X 150 sqmm Copper flexible cable

50

-

-

... More
1C X120 sqmm Copper flexible cable

10

-

-

... More
1C X95 sqmm Copper flexible cable

10

-

-

... More
1C X 25 sqmm Copper flexible cable

60

-

-

... More
1C X 16 sqmm Copper flexible cable

60

-

-

... More
1C X 10sqmm Copper flexible cable

55

-

-

... More
1C X 6sqmm Copper flexible cable

10

-

-

... More
4CX16sq.mm 2XWY

10

-

-

... More
4CX10sq.mm 2XWY

180

-

-

... More
4CX6sq.mm 2XWY

250

-

-

... More
FIRE SEALENT

-

-

-

... More
Supply and installation of Acrylic fire stop sealant CP606 or Approved Equivalent )with minimum 2 hours fire rating when tested in accordance with UL 1479 standards, shall be used along the periphery of ducts & chiller pipes without insulation passing through fire rated walls and floors made of concrete, masonry, metal, gypsum construction to provide up to 2 hours insulation and integrity when subject to the test conditions of UL 1479 standards. The product shall also be age tested as per DafStb guidelines. Sealant to provide sufficient MAF, water and gas tight seal apart from providing an airborne sound transmission reduction (STC of 50) and shall be tested as per DIN 52210 for sound insulation . The product should be tested for mold resistance rating of 0 as determined by ASTM G21-96 and should have a VOC content of approx. 75 g/l as per LEED 2009. The sealant shall be FM approved. All installations to be in full accordance with the manufacturer. The sealant should be tested in accordance with IEC 60068-2-57:1999-11 (Environmental Testing) as per Part 2-57: Test for Vibration-Time-history method and VERTEQII for seismic zone 4. The product shall bear the UL and FM approval logo on the packing where applicable. The rate shall include the mineral wool backing material and other miscellaneous items etc.., Assumed 15% Penetrants Ocupancy. Firestop installation should be done by HAFSC ( Accredated Firestop Speciality Contractor by providing complete installation report using CFS DM). Or using FIT (Firestop Installer Training) Program. As per IFC Guideliness EJ is recomended for non standard openings.-( supply & return air ducts.)

100

-

-

... More
ASSOCIATED CIVIL WORKS

-

-

-

... More
Pedestals : Providing & Laying of Reinforced cement concrete of M20 grade at the level given below, using river sand, 20 mm as down size coarse aggregates, application of necessary admixtures as specified by consultants inclding all leads and lifst, scaffolding wheever necessary, curing as directed, including the cost of shuttering, centering and staging for required height.

70

-

-

... More
Chipping, chassing & Plastering the wall openings in cement mortor 1:6 of 15 mm thick finishing to line and level with sand faced finshing at all levels, including all leads & lifts, scaffolding, curing etc complete

75

-

-

... More
MS RELATED WORKS

-

-

-

... More
Supply,installation.testing of MS related works with nessarry supporting materials for Basement-01 & Basement-02

7500

-

-

... More
ASSOCIATED CIVIL WORKS

-

-

-

... More
Indoor Air quality testing (IAQ testing) for Parameter Such as VOC, CO2 and Bacteria Count After the installation of HVAC indoor units

1

-

-

... More
VARIABLE REFRIGERANT FLOW UNITS

-

-

-

... More
(100% INVERTER TYPE ONLY TO BE QUOTED) - R410A Refrigerant

-

-

-

... More
Supply & Installation of VRV /VRF airconditioning system comprising of Modular type high efficiency Twin Rotary Multiple Compressor with inverter, High efficiency heat transfer Cooling Coil suitable for Environment friendly R410a refrigerant,Air cooled propeller type condenser fan with DC motor drive,interconnecting piping, suction line insulation etc., Micro-processor control panel suitable for automatic operation,High speed calculation inverter control, active oil control mechanism incorporating all safety functions as per equipment specifications & other points as listed below:

-

-

-

... More
The unit mounted starter panel shall be complete with IP-55 protection consisting of power disconnecting switches with fuses, soft starters, for compressor motors, under/over voltage trip, single phase preventers, communication card which can accept 4-20 mA or 2-10 Vdc analog signal.

-

-

-

... More
All components shall be mounted on welded steel base frame, structural steel profiles/panels made out of galvanized sheet steel, protected with primary coat & finished with epoxy paint.

-

-

-

... More
Modular type outdoor units equipped with highly efficient scroll compressors, with inverter type compressor(s),special acryl precoated heat exchanger,low noise condenser fan,auto check function for connection error, auto address & UNIT Price shall be inclusive of outdoor stand price. Shifting & Installing of ODU as per shop drawing is part VRV vendor scope.(ODU Location & Capacity mentioned below). Shifting of Out door units from GF to repective location is part of VRF vendor scope . ODUs shall have service valve station for easy operations and monitoring of system

-

-

-

... More
All VRV units should be compatible for third party BMS integration .necessary integrator should be consider in part HVAC/VRF vendor scope (Bacnet over MSTP protocol to be considered for BMS compatibility requirement). Centralized controller shall be considered combined for all the VRF indoor and outdoor units and same to be located in a specific location as per client requirement.

-

-

-

... More
Factory acceptance test to be conducted for all the units and cost of the same to be included

-

-

-

... More
Testing tools and instruments of approved make and required quantity tobe maintained by Contractor

-

-

-

... More
Contractor shall engage dedicated commissioning manager for project and shall coordinate for all testing activities and documentations

-

-

-

2

-

-

... More
INDOOR UNITS / Ms Stands / Gas

-

-

-

... More
Indoor Unit (IDU): Cooling type All the units should be supplied with Cordless remote control. The following Indoor unit capacities are required for each type of Room. Drycontact should be considered for Auto change over,failure status,overload sequencing etc..

-

-

-

... More
Ductable units

-

-

-

... More
Serving Area: 4 TR Ductable unit

2

-

-

... More
Serving Area: 6TR Ductable unit

2

-

-

... More
Serving Area: 8 TR Ductable unit

2

-

-

... More
Supply & providing of MS stand for VRV ODU along with proper supports-suitable for above configuration

2

-

-

... More
Filling, testing, commissioning including topping up of R410 A Refrigerant.

1

-

-

... More
REFRIGERANT PIPING & REFNET JOINTS

-

-

-

... More
Insulated Refrigerant piping between the indoor units and the outdoor units with minimum pipe thickness of 1.6 mm. The Route length of Refrigerant piping between the outdoor units & Indoor units shall be as per the drawings furnished. The price quoted shall include liquid receiver, on-line accumulator, oil separator & other safety devices for required for total nos of circuits, if required for long distance and first charge of refrigerant & oil for the complete system including piping length required.

-

-

-

... More
All refrigerant pipes shall be of hard drawn pipes in straight lengths shall be used. Wall thickness of all piping shall be 16 guage, 1.6 mm thick

-

-

-

... More
Thick Thermal Insulation of VRV/VRF piping should be Closed cell Elastomeric Nitrile Rubber Insulation. Thermal conductivity of the insulation material shall not exceed 0.035 W/mºK at an average temperature of 0ºC.The product shall have temperature range of -50 ºC to 104ºC. The insulation material shall be fire rated for Class O as per BS 476 Part 6 : 1989 for fire propagation test and for Class 1 as per BS 476 Part 7, 1987 for surface spread of flame test. Water vapour permeability shall be not less than 0.024 perm inch. The density of core Insulation shall be 40 to 60 kg/m3. The Insulation shall be factory finished with Co-extruded UV polymer flexible covering with fire resistance of ASTM E84. Water Vapour permeability as per ASTM E96 for the Jacket Materials 0.05 perm in. UV Resistance (Artifiacial Aging) of the Jacket Material should be complying to ASTM G153.

-

-

-

... More
34.3mm OD (insulation =19 mm thick)

75

-

-

... More
28.6mm OD (insulation =19 mm thick)

75

-

-

... More
22.2mm OD (insulation =13 mm thick)

75

-

-

... More
19.1mm OD (insulation =13 mm thick)

75

-

-

... More
15.9mm OD (insulation =13 mm thick)

50

-

-

... More
12.7mm OD (insulation =13 mm thick)

75

-

-

... More
9.5mm OD (insulation =13 mm thick)

60

-

-

... More
Imported fittings like Y-Joints and headers etc as per the layout( additional supports should consider for both ends of the Y joint)

3

-

-

... More
CABLING & CABLE TRAY

-

-

-

... More
Electrical Cable between Isolator to ODU.Suitable size copper flexible cable with necessary earthing insulation

10

-

-

... More
Providing & fixing of 2 Cx 1.5 sqmm cu. cable for control cum trans-mission between Indoor unit and Out Door Unit through PVC Conduit.

270

-

-

... More
Note:Cable from Electrical panel to isolator excluded in VRV vendor scope.same should capture in Electrical vendor scope. Cable from Isolator to ODU is part of VRV Vendorscope.

-

-

-

... More
Control cabling between the indoor unit, outdoor unit. The cables shall be armoured copper cable and shall be clamped to the wall / truss heavy duty GI clamps.

-

-

-

... More
CABLE TRAY

-

-

-

... More
Factory Fabricated Perforated Cable tray made out of 1.6 mm thick galvanized sheet. for housing copper pipes & drain pipe from Indoor unit to Out door unit & drain pipe terminations at AHU room /PHE drain area .

-

-

-

... More
Quoted rate for installation shall include necessary supports,bends,T joints, anchor fasteners and fixing for supporting the cable tray.

-

-

-

... More
size:150x 50mm

75

-

-

... More
size:300x 50mm

40

-

-

... More
cover for the tray in the balcony/exposed area (similar to the cable tray specifications)

-

-

-

... More
DRAIN PIPING

-

-

-

... More
Supply, and installation insulated CPVC medium class Condensate drain piping with 8 kg/cm2 density, cut to required lengths and installed with all solvent joints, providing and fixing the necessary fittings like flanges,elbows tees, reducers, etc. Supporting arrangements as per site conditions.

-

-

-

... More
The rate quoted shall include the cost of nitrile rubber insulation for pipes running in unconditioned space of 9 mm thick.

-

-

-

... More
50 mm dia

15

-

-

... More
40 mm dia

15

-

-

... More
32 mm dia

15

-

-

... More
25 mm dia

20

-

-

... More
CONDENSATE DRAIN PUMP

-

-

-

... More
Drain Pump Kit with 4 litre storage tank, consisting of Pumps (1W+1SB) suitable for pumping water for a vertically 10m. Each condensate pump should have a 2 litre capacity tank and be capable of pumping water to a height of 6m and a maximum flow of 1250L/hour. It should run continuous and be rated at 0.38A, with a normally closed, 4.0A safety cut out switch wired to the AC unit. The outlet should be 10mm with a non-return valve fitted. In case of failure pump, the alarm should be generated. Non retrun vaves of suitable dia to be provided at the end of each pipe outlet (2 Nos) from the tank. It shall have a control panel which shall have BMS compatibility with Modbus over RS485 output

1

-

-

... More
AUTO SYNCHORINIZATION PANEL

-

-

-

... More
Synchoronization Panel capable of sychronizing Indoor Units to Operate based on the set number of hours, switch ON / OFF in the event of rise in temperature, failure of equipment, schedule change-over.

2

-

-

... More
A / C units should be able to restart automatically after power failure / Interruption

-

-

-

... More
Automatic fault chnageover in case working unit fault

-

-

-

... More
Sequential changeover of operating units with specified timings

-

-

-

... More
Monitoring of high and low temperature conditions

-

-

-

... More
The panel should be provided with potential free contact for fire integration

-

-

-

... More
It Should generate an alarm if the unit trips or the room temperature goes beyond the set point, power fail, HP, LP trip

-

-

-

... More
The panel should be provided with Rs 485 / modbus connectivity for BMS integration

-

-

-

... More
Panel should be SMS module option

-

-

-

... More
Panel should be compatible for 2 Nos of MCB's status

-

-

-

... More
It should give Alarm in form of audible buzzer and indication light and SMS

-

-

-

... More
This controller should monitor low pressure and high pressure of Units

-

-

-

... More
Control cabling of 50 mtr to be considered fror each controller.

-

-

-

... More
The rate quoted shall included the cost of BMS connectivity with RS-485 port.

-

-

-

... More
BUILDING MANAGEMENT SYSTEM (Design, Engineering, Supply, Inspection, testing, erection and commissioning of following items)

-

-

-

... More
MAIN IBMS SERVER HARDWARE (1 MAIN + 1 STANDBY) Supply, Inspection, testing, erection and commissioning Main IBMS Server Hardware (1Working+1Standby) 4th Gen Intel Xeon Scalable (1.9 GHZ / 6-CORE / 15MB / 85W) PROCESSOR , 8 DIMM SLOTS 2Nos. of 8GB DDR4 RAM , WITH NVIDIA GRAPHIC CARD, 8 LFF (3.5INCH) HOT PLUG SAS/SATA OPEN BAY 4 Nos. of HP 2TB 6G SATA 7.2K 3.5IN MDL SC HDD SAS/SAT H240 SMART HBA WITH ENCRYPTION KEY EXTERNAL DVD R/W 1 x 800W/900W GOLD HT PLG PWR ETHERNET 1GB 2-PORT 36I ADAPTER HP ILO (FIRMWARE: HP ILO 4) WITH 2GB NAND + HP STANDARD KEYBOARD & MOUSE + MICROSOFT WINDOWS SERVER 2012 STANDARD WITH ANTIVIRUS AND MS SQL SERVER LICENSE + The Communication protocol shall be one of the Industry Standard Open Protocols such as BACNet, MODBUS etc. System should be scalable.

1

-

-

... More
Supply, installation, testing and commissioning of 3D User Friendly Realtime Graphical User Interface (GUI) BMS Head-End Software. The system should be accessible from anywhere on LAN or WAN or Ethernet without additional licenses. The Communication protocol shall be one of the Industry Standard Open Protocols such as BACNet/IP, Modbus, LonWorks, KNX etc. Software should be scalable & no extra communication driver license required shall be acceptable. The Cost of the Software shall have a inbuilt Server licenses. (Main + Cloud Server) and 5 concurrent user client licenses with upgradable to unlimited web user license. 1. The rate shall inclusive of BTU billing software capable of generating necessary report/billing format for direct billing to the tenants. Provision for Customisation of Software as per customer. Thrd party software shall be accepted for BTU Billing activities. However the same software shall be proven technology in India Market and the OEM of BTU Meter Billing Software must submit the completion certificate and healthy certificate of the Software functional from Multi-User Tenant Corporate Customer. 2. The BMS Head End Software shall have an inbuilt EV Charging Consumption Bill Generation Software Module. The same shall be accepted from 3rd party OEM. However, the rate shall inclusive all the requirement of EV Charging Consumption Bill Generation Software. 3. The rate shall inclusive of all the furnished IO points as per the BMS IO Data Summary with inbuilt soft integration modules for 3rd party equipments integration. The Proposing 3D Graphical User Interface Software shall have a 4500 Hard wired interface points and 18000 3rd Party Integration soft points as per the IO Summary. 4. The software shall have a own property of End User Customer and there is no legal rights to claim from the OEM after successful installation.

1

-

-

... More
Supply, Inspection, testing, erection and commissioning A4 size Laserjet Printer suitable for the application, with driver software.

1

-

-

... More
Supply, installation, testing and commissioning of Client Workstation Intel core 9th Generation Intel Core i9 Processor by latest generation or better, 16GB DDR3 RAM, 64-bit operating system, 1TB SSD for OS and Security Center applications, with a minimum of 16 GB of free disk space to install the Security Center Client Application, 1TB SATA Hard Disk Drive with 7200rpm, GbE Network Interface Card, DVD-RW Standard Keyboard & Mouse with Dual NVIDIA GeForce RTX 2080 Video Card with 21" 4K UHD LED Monitor. Minimum 4 HDMI,1 parallel, 8 USB 2.0, 1 serial, 2 Ultra ATA/100, 2 Optional IEEE1394, 1 USB Keyboard, 1 USB Mouse, 1 Video, 1 Microphone Jack, 1 Line-in jack, 2 x 1GBPS RJ-45 Interface Port. Note: The Configuration mentioned is only Minimum requirement. Vendor to consider as per OEM recommendations in case of higher configurations shall be required as per project functional requirements and the bidder to consider the cost for the same & quote accordingly. The bidder needs to consider the same configuration if OEM will not have an objection for the mentioned specifications. No deviation shall be accepeted.

2

-

-

... More
IP DDC CONTROLLERS WITH NATIVE BACNet / IP CONFIGURABLE: DSupply, installation, testing and commissioning of DDC Controllers, Standalone and Networkable 32 Bit DDC Controllers with I/O module as per enclosed IO List. The controllers shall be capable of standalone operation with real time clock and historical database. The DDC's shall be capable of peer to peer communication without help of system interface controller or PC. The DDCs shall be with suitable IP 55 enclosure for indoor mounted type. DDC Controller must have a inbuilt IoT enabled communication protocol to connect and configuring directly with Cloud BMS Server. Bidder shall Quote Accordingly. Gateway controllers shall not be accepted. The IO Count shall be referred from the IO Data Summary

-

-

-

... More
DDC - TYPE - 01(Refer IO Summary) for Ground Floor Atrium South West Ahu Room

1

-

-

... More
DDC - TYPE - 02(Refer IO Summary) for Ground Floor Atrium North West Ahu Room

1

-

-

... More
DDC - TYPE - 03(Refer IO Summary) for Ground Floor Atrium North East Ahu Room

1

-

-

... More
DDC - TYPE - 04(Refer IO Summary) for Ground Floor Atrium South East Ahu Room

1

-

-

... More
DDC - TYPE - 05(Refer IO Summary) for Ground Floor Cafeteria

1

-

-

... More
DDC - TYPE - 06(Refer IO Summary) for Ground Floor Hub, Cassette, Bank & Coworking space CSU unit

1

-

-

... More
DDC - TYPE - 07(Refer IO Summary) for First Floor Banquet Hall / Multipurpose Hall Ahu

1

-

-

... More
DDC - TYPE - 08(Refer IO Summary) for First Floor Atrium south west & Coworking space Ahu

1

-

-

... More
DDC - TYPE - 09(Refer IO Summary) for First Floor Small Tenant 1A & North west Atrium ,

1

-

-

... More
DDC - TYPE - 10(Refer IO Summary) for First Floor Small Tenant 1B & 1C.

1

-

-

... More
DDC - TYPE - 11(Refer IO Summary) for First Floor Small Tenant 1F & 1G.

1

-

-

... More
DDC - TYPE - 12(Refer IO Summary) for First Floor Atrium North East Ahu Room

1

-

-

... More
DDC - TYPE - 13(Refer IO Summary) for First Floor Dinning Ahu rooms

1

-

-

... More
DDC - TYPE - 14(Refer IO Summary) for First Floor Small Tenant 1D.

1

-

-

... More
DDC - TYPE - 15(Refer IO Summary) for First Floor Small Tenant 1E & South East Atrium ,

1

-

-

... More
DDC - TYPE - 16(Refer IO Summary) for Second Floor Small Tenant 2A

1

-

-

... More
DDC - TYPE - 17(Refer IO Summary) for Second Floor Atrium south west & Small tenant 2F

1

-

-

... More
DDC - TYPE - 18(Refer IO Summary) for Second Floor North west Atrium ,

1

-

-

... More
DDC - TYPE - 19(Refer IO Summary) for Second Floor Small Tenant 2B & 2C.

1

-

-

... More
DDC - TYPE - 20(Refer IO Summary) for Second Floor Small Tenant 2D & 2E.

1

-

-

... More
DDC - TYPE - 21(Refer IO Summary) for Second Floor Atrium North East Ahu Room

1

-

-

... More
DDC - TYPE - 22(Refer IO Summary) for Second Floor Anchore Tenant 2A

1

-

-

... More
DDC - TYPE - 23(Refer IO Summary) for Second Floor Anchore Tenant 2A & South East Atrium ,

1

-

-

... More
DDC - TYPE - 24(Refer IO Summary) for Third Floor Medium Tenant 3A

1

-

-

... More
DDC - TYPE - 25(Refer IO Summary) for Third Floor Atrium south west & Medium tenant 3A

1

-

-

... More
DDC - TYPE - 26(Refer IO Summary) for Third Floor North west Atrium ,

1

-

-

... More
DDC - TYPE - 27(Refer IO Summary) for Third Floor Small Tenant 3A & 3B.

1

-

-

... More
DDC - TYPE - 28(Refer IO Summary) for Third Floor Small Tenant 3C & 3D.

1

-

-

... More
DDC - TYPE - 29(Refer IO Summary) for Third Floor Atrium North East Ahu Room

1

-

-

... More
DDC - TYPE - 30(Refer IO Summary) for Third Floor Medium Tenant 3B

1

-

-

... More
DDC - TYPE - 31(Refer IO Summary) for Third Floor Medium Tenant 3B & South East Atrium ,

1

-

-

... More
DDC - TYPE - 32(Refer IO Summary) for Fourth Floor Small Tenant 4A

1

-

-

... More
DDC - TYPE - 33(Refer IO Summary) for Fourth Floor Atrium south west & Small tenant 4C

1

-

-

... More
DDC - TYPE - 34(Refer IO Summary) for Fourth Floor North west Atrium ,

1

-

-

... More
DDC - TYPE - 35(Refer IO Summary) for Fourth Floor Anchore Tenant 4A

1

-

-

... More
DDC - TYPE - 36(Refer IO Summary) for Fourth Floor Medium Tenant 4A & 4B.

1

-

-

... More
DDC - TYPE - 37(Refer IO Summary) for Fourth Floor Atrium North East Ahu Room

1

-

-

... More
DDC - TYPE - 38(Refer IO Summary) for Fourth Floor Small Tenant 4B

1

-

-

... More
DDC - TYPE - 39(Refer IO Summary) for Fourth Floor South East Atrium ,

1

-

-

... More
DDC - TYPE - 40(Refer IO Summary) for Fifth Floor Small Tenant 5D

1

-

-

... More
DDC - TYPE - 41(Refer IO Summary) for Fifth Floor Atrium south west

1

-

-

... More
DDC - TYPE - 42(Refer IO Summary) for Fifth Floor North west Atrium & Small Tenant 5A ,

1

-

-

... More
DDC - TYPE - 43(Refer IO Summary) for Fifth Floor Anchore Tenant 5A

1

-

-

... More
DDC - TYPE - 44(Refer IO Summary) for Fifth Floor Medium Tenant 5A & 5B.

1

-

-

... More
DDC - TYPE - 45(Refer IO Summary) for Fifth Floor Atrium North East Ahu Room

1

-

-

... More
DDC - TYPE - 46(Refer IO Summary) for Fifth Floor Small Tenant 5B

1

-

-

... More
DDC - TYPE - 47(Refer IO Summary) for Fifth Floor South East Atrium & Small tenant 5C ,

1

-

-

... More
DDC - TYPE - 48(Refer IO Summary) for Sixth Floor Small Tenant 6D

1

-

-

... More
DDC - TYPE - 49(Refer IO Summary) for Sixth Floor Atrium south west

1

-

-

... More
DDC - TYPE - 50(Refer IO Summary) for Sixth Floor North west Atrium & Small Tenant 6A ,

1

-

-

... More
DDC - TYPE - 51(Refer IO Summary) for Fifth Floor Anchore Tenant 6A

1

-

-

... More
DDC - TYPE - 52(Refer IO Summary) for Fifth Floor Medium Tenant 6A & 6B.

1

-

-

... More
DDC - TYPE - 53(Refer IO Summary) for Fifth Floor Atrium North East Ahu Room

1

-

-

... More
DDC - TYPE - 54(Refer IO Summary) for Fifth Floor Small Tenant 6B

1

-

-

... More
DDC - TYPE - 55(Refer IO Summary) for Fifth Floor South East Atrium & Small tenant 6C ,

1

-

-

... More
DDC - TYPE - 65(Refer IO Summary) for Utility Building Fire, PHE Pumps and Tanks, DDC located at Pump Room

1

-

-

... More
DDC - TYPE - 66(Refer IO Summary) for Utility Building Pumps room ventilation fans, DDC located at Pump Room

1

-

-

... More
DDC - TYPE - 67(Refer IO Summary) for Utility Building Chiller Plant & Electrical room ventilation fans, DDC located at Pump Room

1

-

-

... More
IP DDC CONTROLLERS WITH NATIVE BACNet / IP CONFIGURABLE: DSupply, installation, testing and commissioning of DDC Controllers, Standalone and Networkable 32 Bit DDC Controllers with I/O module as per enclosed IO List. The controllers shall be capable of standalone operation with real time clock and historical database. The DDC's shall be capable of peer to peer communication without help of system interface controller or PC. The DDCs shall be with suitable outdoor type controllers it shall be IP66 complete with all wiring and accessories. DDC Controller must have a inbuilt IoT enabled communication protocol to connect and configuring directly with Cloud BMS Server. Bidder shall Quote Accordingly. Gateway controllers shall not be accepted. The IO Count shall be referred from the IO Data Summary

-

-

-

... More
DDC - TYPE - 56(Refer IO Summary) for Terrace Floor TFA, Toilet & Electrical room Exhaust fan DDC located at 6F South west Atrium Ahu Room

1

-

-

... More
DDC - TYPE - 57(Refer IO Summary) for Terrace Floor TFA, Toilet & Electrical room Exhaust fan DDC located at 6F North west Atrium Ahu Room

1

-

-

... More
DDC - TYPE - 58(Refer IO Summary) for Terrace Floor TFA, Toilet & Electrical room Exhaust fan DDC located at 6F South East Atrium Ahu Room

1

-

-

... More
DDC - TYPE - 59(Refer IO Summary) for Terrace Floor TFA, Toilet & Electrical room Exhaust fan DDC located at 6F North East Atrium Ahu Room

1

-

-

... More
DDC - TYPE - 60(Refer IO Summary) for Terrace Floor TFA, Toilet & Electrical room Exhaust fan DDC located at 6F North East Atrium Ahu Room

1

-

-

... More
DDC - TYPE - 61(Refer IO Summary) for Terrace Floor TFA unit, DDC located at 6F - 6A Anchore Ahu Room

1

-

-

... More
DDC - TYPE - 62(Refer IO Summary) for Terrace Floor Pressurization unit (lift well, Lift lobby & stairwell), DDC located at 6F - Atrium Ahu Room

1

-

-

... More
DDC - TYPE - 63(Refer IO Summary) for Terrace Floor critical room air cooled chiller, DDC located at 6F - Ahu Room

1

-

-

... More
DDC - TYPE - 64(Refer IO Summary) for Terrace Floor fire Booster Pump & OHT Tanks, DDC located at 6F - Ahu Room

1

-

-

... More
PORTABLE OPERATOR TERMINAL: Portable Operator Terminal : capable of connecting to one of the Controllers on the Communication bus and view parameters of the complete system. The Terminal should be capable of viewing / changing parameters and trend the specified parameters as per requirement

2

-

-

... More
Supply installation testing and commissioning of SMS & E- Mail alram notification module with unlimited user capability , SMS paging and Email facility for tranmitting specified alarm to designated proposal.

1

-

-

... More
THIRD PARTY SOFT INTEGRATION: Supply, installation, testing and commissioning of Required Gateways / Open Protocol Software for integrating the foll third party system communicating on one of the Standard Open Protocols such as BACNet, ModBus, M-Bus, J-Bus etc - Vendor to considered required No. of Integrators for soft point qty's mentioned in IO summary. Maximum qty in one loop cannot exceed 20 nos. Accordingly integrator qty to be selected. a. Energy Meters (180 meters - 7 points each - Total 1260 points - Modbus over RS485 protocol) b. DG / Transformer Sync panel - Total 200 points - Modbus over RS485 protocol) c. UPS - (40 points - Modbus over RS485 protocol / BACnet over MSTP) d. Secondary pump PLC panel (100 points - Modbus over RS485 protocol / BACnet over MSTP) e. EC fan (80 Nos- 10 points each - Total 800 points - Modbus over RS485 protocol / BACnet over MSTP) f. VFD (15 Nos- 10 points each - Total 150 points - Modbus over RS485 protocol) g. Fire alarm panels & MCC panel for pumps (5000 points - Modbus over RS485 protocol / BACnet over MSTP) h. CHW cassette / Hi wall units (30 Nos -5 points each - Total 150 points - Modbus over RS485 protocol) i. Water meter integration (10 Nos - 5 points per meter - total 50 points - Modbus over RS485 protocol / BACnet over MSTP) j. Elevator monitoring system - ( 14 Nos - 5 points each - total 70 points - Modbus over RS485 protocol / BACnet over MSTP) k. Tenent Billing system - (1350 points - M-Bus / Modbus over RS485 protocol / BACnet over MSTP) l. Chiller plant Manager - (120point per chiller, total-480 points- Modbus over RS485 protocol / BACnet over MSTP) m. VRV system - 10point per each unit, total - 80points - Modbus over RS485 protocal / BACnet over MSTP n. PHE PUMP PLC - (100 points - Modbus over RS485 protocol / BACnet over MSTP) o. Solar System Panel Integration - (100 points - Modbus over RS485 protocol / BACnet over MSTP)

1

-

-

... More
Temperature Sensors - Duct Type - Indoor. Supply, installation, testing and commissioning of Temperature sensor shall be of the Resistance Temperature detector (RTD) type or thermistor. These shall be two wire type . It shall be with rigid stem and of averaging type. These shall be suitable for duct installation. Accuracy shall be ± 2 deg C. Temperature range shall be 0 -50 deg C.

101

-

-

... More
Temperature Sensors - Immersion type - Cold Water - Indoor Supply, installation, testing and commissioning of Temperature sensor shall be of the Resistance Temperature detector (RTD) type or thermistor. These shall be two wire type. It shall be provided with separate Brass thermo well. These shall be manufactured from bar stock with hydrostatic pressure rating of at least 10 kgf/cm2. Accuracy shall be ± 2 deg C. Temperature range shall be 0 -50 deg C.

262

-

-

... More
Temperature & RH Sensors - Wall Mount type - Outdoor (For Ambient T & RH). Supply, installation, testing and commissioning of Sensor shall be provided with a sun shield. Sensors shall be of capacitance type with an effective sensing range of 0% to 93% RH. Accuracy shall be + 2% or better. Duct mounted humidity sensors shall be provided with a sampling chamber. Sensors shall be provided with a housing. Temperature range shall be 0 -50 deg C and accuracy shall be ± 2 deg C. Temperature sensor shall be of the Resistance Temperature detector (RTD) type or thermistor

1

-

-

... More
Temperature & RH Sensors - Wall Mount type - Indoor (For Room T & RH) with display Supply, installation, testing and commissioning of Sensors shall be of capacitance type with an effective sensing range of 0% to 93% RH. Accuracy shall be + 2% or better. Duct mounted humidity sensors shall be provided with a sampling chamber. Temperature range shall be 0 -50 deg C and accuracy shall be ± 2 deg C. Temperature sensor shall be of the Resistance Temperature detector (RTD) type or thermistor

19

-

-

... More
Temperature & RH Sensors - Duct Mount type - Indoor (For Room T & RH) Supply, installation, testing and commissioning of Sensors shall be of capacitance type with an effective sensing range of 0% to 93% RH. Accuracy shall be + 2% or better. Duct mounted humidity sensors shall be provided with a sampling chamber. Temperature range shall be 0 -50 deg C and accuracy shall be ± 2 deg C. Temperature sensor shall be of the Resistance Temperature detector (RTD) type or thermistor

69

-

-

... More
Velocity Sensors - Duct Mount type - Indoor Supply, installation, testing and commissioning of Air Velocity Sensor shall be integrated Surface / Duct mounted type on the field. These shall work on 24V AC/DC supply with +/- 10% variation the output being standard type i.e. 4-20 mA / 0- 10 Volts etc with an accuracy of +/- 3%

89

-

-

... More
Duct Static Pressure Sensor (For AHU static pressure monitoring). Supply, installation, testing and commissioning of Range shall be 0-500 Pa, Accuracy at ±1% FS, It shall be IP54 rated. Vertically mounted with pressure connections pointing downwards.

92

-

-

... More
Differential Pressure Switch for Fan Status (Outdoor type) Supply, installation, testing and commissioning of These shall be diaphragm operated. Switches shall be supplied with air connections permitting their use as static or differential pressure switches. The switch shall be of differential pressure type complete with connecting tube and metal bends for connections to the duct. The housing shall be IP 67 rated.

24

-

-

... More
Differential Pressure Switch for Fan Status (Indoor type) Supply, installation, testing and commissioning of These shall be diaphragm operated. Switches shall be supplied with air connections permitting their use as static or differential pressure switches. The switch shall be of differential pressure type complete with connecting tube and metal bends for connections to the duct

2

-

-

... More
Differential Pressure Switch - Filter Status (Outdoor type) Supply, installation, testing and commissioning of These shall be diaphragm operated. Switches shall be supplied with air connections permitting their use as static or differential pressure switches. The switch shall be of differential pressure type complete with connecting tube and metal bends for connections to the unit. The housing shall be IP 67 rated.

24

-

-

... More
Differential Pressure Switch - Filter Status (Indoor type) Supply, installation, testing and commissioning of These shall be diaphragm operated. Switches shall be supplied with air connections permitting their use as static or differential pressure switches. The switch shall be of differential pressure type complete with connecting tube and metal bends for connections to the unit

163

-

-

... More
Water Level Switch Supply, installation, testing and commissioning of These shall be paddle type and suitable for the type of liquid flowing in the line. Output shall be 1NO/1NC potential free

6

-

-

... More
Hydrogen Sensor: upply, installation, testing and commissioning of Wall Mount type - Indoor - It shal be flame proof type. Accuracy shall be +/- 10% FSD of H2%. Response time shall be less than 3 seconds

1

-

-

... More
CO2 Sensor - Duct Type - Indoor (in AHU Room Return Air path) Supply, installation, testing and commissioning of These shall work on 24V AC/DC supply with the output being standard type i.e. 4-20 mA / 0- 10 Volts etc. Response time of the detector shall be 10 minutes. Range of the sensor shall be 0 to 2000 PPM

76

-

-

... More
Supplying, laying, termination, testing and commissioning of signal cables. 2 Core x 1.0 Sqmm, PVC insulated, tinned copper conductor cable Armoured Shielded ATC FRLS cable.

13338

-

-

... More
Supplying, laying, termination, testing and commissioning of signal cables. 4 Core x 1.0 Sqmm, PVC insulated, tinned copper conductor cable Armoured Shielded ATC FRLS cable.

15620

-

-

... More
Supplying, laying, termination, testing and commissioning of signal cables. 2 Core x 1.5 Sqmm, PVC insulated, tinned copper conductor cable Armoured Shielded ATC FRLS cable.

6000

-

-

... More
Supplying, laying, termination, testing and commissioning of signal cables. 3 Core x 1.5 Sqmm, PVC insulated, copper conductor cable Un-Armoured / Flexible FRLS cable.

501

-

-

... More
Supplying, laying, testing and commissioning FRLS PVC conduit with junction boxes, saddles, clamps, bends, fittings, etc. for communication cables, control cables, wires, etc. 20mm PVC Conduit.

2837

-

-

... More
Supplying, laying, testing and commissioning FRLS PVC conduit with junction boxes, saddles, clamps, bends, fittings, etc. for communication cables, control cables, wires, etc. 25mm PVC Conduit.

5319

-

-

... More
Supplying, installing, testing and commissioning of 2 mm thick Hot dip Galvanised GI perforated cable trays of the following sizes complete with angle iron supports/hanging arrangement etc. Wedge supports shall be considered. All supports shall be Unistrut supports. 2 mm thick powder coated cable tray cover shall be considered. All bends, fittings, offsets, etc. shall be factory fabricated only. Site fabrication is not allowed. 300mmX50mmX2mm

1900

-

-

... More
Supplying, installing, testing and commissioning of 2 mm thick Hot dip Galvanised GI perforated cable trays of the following sizes complete with angle iron supports/hanging arrangement etc. Wedge supports shall be considered. All supports shall be Unistrut supports. 2 mm thick powder coated cable tray cover shall be considered. All bends, fittings, offsets, etc. shall be factory fabricated only. Site fabrication is not allowed. 150mmX50mmX2mm

375

-

-

... More
Supplying, installing, testing and commissioning of 2 mm thick Hot dip Galvanised GI perforated cable trays of the following sizes complete with angle iron supports/hanging arrangement etc. Wedge supports shall be considered. All supports shall be Unistrut supports. 2 mm thick powder coated cable tray cover shall be considered. All bends, fittings, offsets, etc. shall be factory fabricated only. Site fabrication is not allowed. 100mmX50mmX2mm

1320

-

-

... More
Supply and providing of PVC cable truf complete with all fittings and accessories 100mm (W) x 75mm (D)

660

-

-

... More
DATA NETWORKING & TELECOM SYSTEM (ICT)

-

-

-

... More
Supply, installation, testing and commissioning of Core Switch shall have minimum 48 x 1/10 SFP, 4*1/10G SFP Ports. Note: Bidder shall refer the Technical Tender Specifications for details for product compliance accordingly.

2

-

-

... More
Supply, installation, testing and commissioning of 1G SFP Transceiver Module for Uplink for Segment / Distribution POE switch

100

-

-

... More
Supply, installation, testing and commissioning of 10G SFP Transceiver Module for Uplink / Downlink for Core switch

4

-

-

... More
48 Port PoE+ Edge / Distribution Switch: Supply, installation, testing and commissioning of Edge Switch shall have minimum 48 *100/1000 RJ45 PoE+ ports and 4 x 1/10G SFP ports with redundant power supply. Minimum required PoE budget (48Port * 30W = 1440) 1440 Watts. Note: Bidder shall refer the Technical Tender Specifications for details for product compliance accordingly.

18

-

-

... More
24 Port PoE+ Edge / Distribution Switch: Supply, installation, testing and commissioning of Edge Switch shall have minimum 24 *100/1000 RJ45 PoE+ ports and 4 x 1/10G SFP ports with redundant power supply. Minimum required PoE budget (24Port * 30W = 720) 720 Watts. Note: Bidder shall refer the Technical Tender Specifications for details for product compliance accordingly.

5

-

-

... More
8 Port PoE+ Edge / Distribution Switch: Supply, installation, testing and commissioning of Edge Switch shall have minimum 8 *100/1000 RJ45 PoE+ ports and 4 x 1/10G SFP ports with redundant power supply. Minimum required PoE budget (8Port * 30W = 240) 240 Watts. Note: Bidder shall refer the Technical Tender Specifications for details for product compliance accordingly. The rate shall inclusive of necessary 16A Power Socket, Switch, LIU, Patch Panel, IP65 Rating weather proof Enclosure Box with DIN rail Mount arrangement to mount the Network Switch, LIU, Patch Panel etc.

6

-

-

... More
Wi-Fi Manager / Controller: Supply, installation, testing and commissioning of Centralized management Wi-Fi Manager / Controller Note: Bidder shall refer the Technical Tender Specifications for details for product compliance accordingly.

1

-

-

... More
Wi-Fi Access Points: Supply, installation, testing and commissioning of Wi-Fi Access Points Note: Bidder shall refer the Technical Tender Specifications for details for product compliance accordingly.

16

-

-

... More
Supply, installation, Testing and Commissioning of Firewall and the key features are highlighted below and the detail technical requirement shall be refered in Tender Technical Specifications and the same shall be complied with no deviation. a. Major supported features: b. Anti-Virus c. Intrusion Prevention System (IPS) d. Web filtering e. E-mail filtering, including protection against spam and grayware f. Data Leak Prevention (DLP) g. Application Control h. Traffic inspection i. Content inspection and filtering j. Security Profiles components k. Security Profiles/lists/sensors l. Logging and reporting

1

-

-

... More
Supply, installation, Testing and Commissioning of Enterprises Network Management System (EMS) and the same shall be subcription shall be considered for 36 months from the handing over the project. The Key Features are highlighted below and the detail technical requirement shall be refered in Tender Technical Specifications and the same shall be complied with no deviation. To ensure that ICT systems are delivered at the performance level envisaged, it is important that an effective monitoring and management system be put in place. It is thus proposed that a proven Enterprise Management System (EMS) is proposed by the bidder for efficient management of the system, reporting, SLA monitoring and resolution of issues. Various key components of the EMS to be implemented as part of this engagement are a. Network Monitoring System b. Server Monitoring System c. Helpdesk System d. The solution should provide a unified web-based console which allows role-based access to the users.

1

-

-

... More
Supply, installation, Testing and Commissioning of Network Managment System Server with the following configuration for Enterprises Network Management System for Building Operations: Netowrk Management Server machine: Includes Server, Windows Server Standard, SQL Server Standard. Intel Xeon Silver 3104 Processor, 8 MB L3 Cache, 6 Cores, 6 Threads 3 x 8GB RDIMM, 2666MT/s 1 x 1TB 10K RPM SAS 2.5in Hot-plug Hard Drive 2GB Network Card Windows Server 2016/2019 Standard , 104, 12 function key DD, 21" LCD Monitor, Wireless Mouse, USB Keyboard, CD/DVD Combo Writer, TCP/IP Connection. Note: The Configuration mentioned is only Minimum requirement. Vendor to consider as per OEM recommendations in case of higher configurations shall be required as per project functional requirements and the bidder to consider the cost for the same & quote accordingly. The bidder needs to consider the same configuration if OEM will not have an objection for the mentioned specifications. No deviation shall be accepeted. The Server shall be Balde Type and its should be Rack mounted. Tower type shall not be accepted

1

-

-

... More
Supply, laying, termination of both end (Field & Rack end) and Testing of Cat 6A U/FTP Cable, 4 pair, 23 AWG & UL listed and ETL tested. Bidder shall refer the Technical Tender Specifications for details for product compliance accordingly. Note: 25 Years warranty certification by OEM with Fluke test report shall be provided by the contractor to Employer. There no additional cost shall be provided for Fluke test and certifications.

32358

-

-

... More
Supply, Installation, Testing & Commissioning of 4 Pair Un-armoured 0.5mm Cable - Telephone

7528

-

-

... More
Supply, Installation, Testing & Commissioning CAT 6A Modular 24 Port Patch Panel fully loaded (Tool Less) - with Cable Manager

41

-

-

... More
Supply, Installation, Testing & Commissioning of Tool-less Cat 6A UTP Information Outlet with shutter or integrated dustcover

337

-

-

... More
Supply, Installation, Testing & Commissioning of RJ 11 Information Outlet with shutter or integrated dustcover

155

-

-

... More
Supply, Installation, Testing & Commissioning of Single / Dual Face plate for Field side, the rate shall inclusive of Flush Box - 3 Module to mount the face plate in surface, conseal, ceiling etc.

492

-

-

... More
Supply, Installation, Testing & Commissioning of Cat 6A - RJ 45 IDC plug / CCA connector UL listed and ETL tested for CCTV - Camera Side

446

-

-

... More
Supply, Installation, Testing & Commissioning of CAT 6A UTP LSZH Patch card - 1 M length

779

-

-

... More
Supply, Installation, Testing & Commissioning of CAT 6A UTP LSZH Patch card - 2 M length

283

-

-

... More
Supply, laying, termination of both end (Field & Rack end) and Testing of 12 Core OM4 Multi Mode fiber, Outdoor ECCS Armoured Unitube - LSZH outer sheath, 1500N Tensile Strength, 2000N Crush Resistance and OD 9mm. Bidder shall refer the details of technical requirement in Technical Specifications document. Note: 25 Years warranty certification by OEM with Fluke test report shall be provided by the contractor to Employer. There no additional cost shall be provided for Fluke test and certifications.

2895

-

-

... More
Supply, Installation, Testing & Commissioning of 1U Sliding Fibre panel (LIU) rack-mount 24 Fiber with splice holder, cable spool and loaded with LC Adapter and LC OM4 Pigtail at Each HUB Room

20

-

-

... More
Supply, Installation, Testing & Commissioning of LC/LC Single Mode / Multi mode Patch Cord MM OM4 bending insensitivity - 2M

84

-

-

... More
Supply and Installation of 19", 42U Rack, 800mm(W) x 800mm (D) with Front & Rear Perforated Door with lock, 1 Shelf 575 mm, castors and mounting hardware packet of 20, PDU 6 x 5/15 A(1) and 4 Nos Exhaust Fans Note: Bidder shall refer the details of technical requirement in Technical Specifications document.

9

-

-

... More
Supply and Installation of 19", 32U Rack, 800mm(W) x 800mm (D) with Front & Rear Perforated Door with lock, 1 Shelf 575 mm, castors and mounting hardware packet of 20, PDU 6 x 5/15 A(1) and 4 Nos Exhaust Fans Note: Bidder shall refer the details of technical requirement in Technical Specifications document.

7

-

-

... More
Supply and Installation of 19", 12U Rack, 600mm(W) x 600mm (D) with Front & Rear Perforated Door with lock, 1 Shelf 575 mm, castors and mounting hardware packet of 5, PDU 6 x 5/15 A(1) and 2 Nos Exhaust Fans Note: Bidder shall refer the details of technical requirement in Technical Specifications document.

5

-

-

... More
Supply and Installation of 19", Rack 9U, 600mm(W) x 600mm (D) with Front & Rear Perforated Door with lock, 1 Shelf 575 mm, castors and mounting hardware packet of 5, PDU 6 x 5/15 A(1) and 2 Nos Exhaust Fans Note: Bidder shall refer the details of technical requirement in Technical Specifications document.

3

-

-

... More
Supply, Installation, Testing & Commissioning of Server Gateway like Architecture VoIP Based IP PBX, with Industry Standard CPU based on IP at core with support for hot redundant configuration. IP PBX System Machine should be inbuilt 256 Analog and 100 IP Extensions and it can be expandable upto 896 Analog & 400 IP Extensions, 8 Trunk line + 30 SIP Trunk + 8 Digital Extension. Note: Software shall be installed in Access Control System Servers and Client licenses to be installed in Access Control System Workstation.

1

-

-

... More
Supply, Installation, Testing & Commissioning of 24 Key Digital phone - Operator phone, 480 x 272 pixels back light color display or better with LCD Display

2

-

-

... More
Supply, Installation, Testing & Commissioning of IP Phone: Display Size: 2.8 Inch, 320x240 Color Display Gigabit Ethernet Port

51

-

-

... More
Supply, Installation, Testing & Commissioning of Caller ID Telephone with Speaker

14

-

-

... More
Supply, Installation, Testing & Commissioning of 10 Pair Un-armoured 0.5mm Cable - Telephone

1615

-

-

... More
Supply, Installation, Testing & Commissioning of 20 Pair Un-armoured 0.5mm Cable - Telephone

65

-

-

... More
Supply, Installation, Testing & Commissioning of 50 Pair Un-armoured 0.5mm Cable - Telephone

65

-

-

... More
Supplying and fixing of following sizes of Medium Class PVC conduit along with accessories in surface / recess including cutting the wall and making good the same in case recessed conduit as required 25mm PVC Conduit.

21823

-

-

... More
Supplying and Laying of following Size DWC HDPE pipe ISI Marked along with all accessories like socket, bend, coupler etc., confirming to IS 14930 Part II complete with fitting, cutting and joining etc., direct in ground (750mm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required 63mm dia (OD-63mm & ID-51mm Nominal) Note: OD - Outer Diameter & ID - Inner Diameter

950

-

-

... More
Supply, Installation, Testing & Commissioning of 10 pair Floor MDF Box with krone module with Accessories to compete the work. The rate shall inclusive of All necessary jumper cables from IP-ABX Machine and interconnection tags, IP 55 Enclosures, Lock and keys etc.

5

-

-

... More
Supply, Installation, Testing & Commissioning of 20 pair Floor MDF Box with krone module with Accessories to compete the work. The rate shall inclusive of All necessary jumper cables from IP-ABX Machine and interconnection tags, IP 55 Enclosures, Lock and keys etc.

11

-

-

... More
Supply, Installation, Testing & Commissioning of 50 pair Floor MDF Box with krone module with Accessories to compete the work. The rate shall inclusive of All necessary jumper cables from IP-ABX Machine and interconnection tags, IP 55 Enclosures, Lock and keys etc.

1

-

-

... More
Supply, Installation, Testing & Commissioning of 500 (250 + 250) pair Master MDF Box with krone module with Accessories to compete the work. The rate shall inclusive of All necessary jumper cables from IP-ABX Machine and interconnection tags, IP 55 Enclosures, Lock and keys etc.

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.