Tamil Nadu Urban Habitat Development Board Tender

Search from a plethora of business opportunities for Tamil Nadu tenders posted on the eProcurement TamilNadu website and other online and offline sources. Here, on BidAssist, you can find the best tender opportunities to boost your enterprise by finding work in Tamil Nadu government tenders, PSUs, Municipal Corporations and more. Read on to learn about the bidder registration process, DSC and more.

Tamil Nadu Urban Habitat Development Board - TNUHDB Tender

Works
Civil And Construction
Building Construction
Water Storage And Supply
Electrical Works
Eprocure
Opening Date19 Dec 2024
Closing Date6 Jan 2025
Tender Amount₹ 2,07,21,00,000 
Notes
Download

Costs

Summary

Reconstruction Of 1500 Tenements At East Cemetery Road

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Earth work excavation for foundation with all leads and lifts in all soils and subsoil’s to the required depth as may be directed except hard rock requiring blasting inclusive of shoring strutting and bailing out water wherever necessary refilling the sides of foundation with excavated earth in layers of 15 cm thickness well consolidated depositing the surplus earth in places shown and leveling the site with all initial leads and lifts etc complete complying with relevant standard specification etc complete in all respects as directed by departmental officers.

3835

-

-

... More
Filing in foundation and basement with M-Sand in layers not exceeding 15 cms thick well watered rammed and consolidated complying with relevant standard specification including the cost of Supplying M-Sand etc., complete in all respects as directed by the departmental officers.

330

-

-

... More
Filling in foundation and basement with Quarry dust in layers not exceeding 15 cm thick well watered rammed and consolidated complying with relevant standard specification including the cost of supplying Quarry dust etc., complete in a respects as directed by the departmental officers

4193

-

-

... More
Cement concrete 1:4:8 (one of cement, four of M-sand and eight of hard broken stone) using 40mm size hard broken stone inclusive of shoring, strutting, bailing out water, ramming, curing, etc complete in all respect as directed by the departmental officers.

882

-

-

... More
Supplying fabricating and placing the following kinds of steel grills for reinforcement Fe 500D Grade steel reinforcement bars as per IS 786:1979 for all reinforced cement concrete works such as plinth beam, lintels, beams, sunshade, roof and floor slabs etc., including cost of steel and fabricating the reinforcement grills in position etc., complete in all respect as directed by the departmental officer ( In all floors) (The rate to include the cost of binding wire steel also, steel rods for all sizes)

5866

-

-

... More
Providing form work for centering, shuttering etc., for all reinforced concrete work such as plinth beam, raft beam, raft slab, grade beam etc., including strutting and shuttering wherever required using MS sheets of suitable size of BG 10, stiffened with MS angle of size 25mm x 25mm x 3mm laid over silver oak (Country wood) joists of size 10cm x 6.5 cm (Spaced about 91cm center to center) distance and supported by casurina props of size 10cm-13cm dia (spaced at 75 cm center to center) and removing the same after a specified period without damaging RCC works in all floors etc., complete in all respects as directed by the departmental officer. (for column footing, Grade beam / Plinth beam)

12175

-

-

... More
Providing form work for centering, shuttering etc., for all reinforced concrete work like slab, beams, lintels, loft etc., including shuttering, upto 3.00m high using MS sheet of size 90cm x 60cm and BG 10, stiffened with MS angle of size 25mm x 25mm x 3mm laid over silver oak (Country wood) joists of size 10cm x 6.5 cm (Spaced about 91cm center to center) distance and supported by casurina props of size 10cm-13cm dia (spaced at 75 cm center to center) and removing the same after a specified period without damaging RCC works in all floors etc., complete in all respects as directed by the departmental officer. (For Slabs, Lintels & Lofts)

156276

-

-

... More
Providing form work for centering, shuttering etc., for all reinforced concrete work like lintels, window boxing etc., including shuttering, upto 3.00m high using MS sheet of size 90cm x 60cm and BG 10, stiffened with MS angle of size 25mm x 25mm x 3mm laid over silver oak (Country wood) joist of size 10 cm x 6.5 cm (spaced about 91cm centre to centre) distance and supported by casurina props of size 10cm to 13cm dia (spaced at 75cm centre to centre) and removing the same after a specified period without damaging RCC works in all floors etc complete in all respects as directed by the departmental officer. (Sunshade/Window/Boxing / column)

41090

-

-

... More
Brickwork in cement mortar 1:5 (One of cement and five of M-sand) using fly ash bricks of size 230mm X 110mm X 70mm in foundation and basement including dewatering wherever necessary proper setting and curing etc. complete in all respects as directed by the departmental officer.

700

-

-

... More
Brick Work in Cement Mortar 1:6 (One of cement and Six of M-sand) using fly ash bricks of size 230mm X 110mm X 70mm for superstructure in the following floors including fixing the frames of doors and windows scaffolding, proper setting curing etc., complete in all respect as directed by the departmental officers.

-

-

-

... More
Stilt Floor

18

-

-

... More
First Floor

18

-

-

... More
Second Floor

18

-

-

... More
Third Floor

18

-

-

... More
Fourth Floor

18

-

-

... More
Fifth Floor

18

-

-

... More
Sixth Floor

18

-

-

... More
Seventh Floor

18

-

-

... More
Eighth Floor

18

-

-

... More
Nineth Floor

18

-

-

... More
Tenth Floor

18

-

-

... More
Eleventh Floor

416

-

-

... More
In Terrace Floor

57

-

-

... More
Masonry work using AAC Blocks (Auto Claved Aerated Concrete Blocks) in Cement Mortar 1:6 (One of cement and Six of M-sand) of size 600mm X 200mm X 200mm for superstructure in the following floors including proper setting curing etc., complete in all respect as directed by the departmental officers.

-

-

-

... More
Stilt Floor

545

-

-

... More
First Floor

835

-

-

... More
Second Floor

835

-

-

... More
Third Floor

835

-

-

... More
Fourth Floor

835

-

-

... More
Fifth Floor

835

-

-

... More
Sixth Floor

835

-

-

... More
Seventh Floor

835

-

-

... More
Eighth Floor

835

-

-

... More
Nineth Floor

835

-

-

... More
Tenth Floor

835

-

-

... More
Eleventh Floor

835

-

-

... More
Masonry Walls using AAC Blocks (Auto Claved Aerated Concrete Blocks) in Cement Mortar 1:5 (One of cement five of M-sand) of size 600mm X 200mm X 100mm for superstructure in the following floors including fixing the frames of doors and windows scaffolding, proper setting curing etc., complete in all respect as directed by the departmental officer.

-

-

-

... More
Stilt Floor

1185

-

-

... More
First Floor

3181

-

-

... More
Second Floor

3181

-

-

... More
Third Floor

3181

-

-

... More
Fourth Floor

3181

-

-

... More
Fifth Floor

3181

-

-

... More
Sixth Floor

3181

-

-

... More
Seventh Floor

3181

-

-

... More
Eighth Floor

3181

-

-

... More
Nineth Floor

3181

-

-

... More
Tenth Floor

3181

-

-

... More
Eleventh Floor

3181

-

-

... More
Plastering the walls with Cement Mortar 1:5 (One of cement and five of P-sand) 12mm thick including providing band cornice, curing, finishing, etc., complete in all respect as directed by the departmental officers.

290677

-

-

... More
Plastering with CM 1:3 (One of cement and Three of P-sand) 20mm thick with necessary water proofing compound at the rate of 1.06 Kg/ 10 M2 of weight of cement including finishing smooth proper setting, curing etc complete in all respects as directed by the departmental officers.

2223

-

-

... More
Plastering with CM 1:4 (One of cement and Four of P-sand) 20mm thick with necessary water proofing compound at the rate of 1.06 Kg/ 10 M2 of weight of cement including finishing smooth proper setting, curing etc complete in all respects as directed by the departmental officers.

3700

-

-

... More
Special ceiling plastering for all RCC works in cement mortar 1:3 (One of cement and three of P-Sand) 10mm thick including hacking the RCC surface, providing necessary water band using the same mix of mortar wherever necessary proper finishing, curing, scaffolding etc., complete with relevant standard specification, complete in all respect as directed by the departmental officer.

57937

-

-

... More
Providing 7 cm thick stair case parapet wall using using Fly ash bricks of size 230x110x70mm in cement mortor 1:4 (one of cement and four of M-sand ) and plastering the hand rail portion only with red oxide plastering in cement mortar 1:4 (one of cement four of P-sand) 20mm thick using 9.80kg of red oxide powder per 10m2 and plastering either side of parapet with cement mortar 1:4 (one of cement and four of P-sand ) 20mm thick including providing skirting, finishing smooth in all floors etc., complete in all respects as directed by the departmental officers. (In All Floors)

905

-

-

... More
Cement concrete 1:5:12.5 (One of cement ,five of M-sand and twelve and half of broken brick jelly ) using 20mm size broken brick jelly inclusive of shoring, strutting, bailing out water ramming curing etc complete in all respect as directed by the departmental officers.

447

-

-

... More
Weathering course in concrete broken brick jelly 20mm size in pure slacked lime over RCC roof slab the proportion being 32:12 1/2 (Thirty two parts of broken brick jelly and twelve and half of slacked lime) laying to a thickness of 110mm and compacted and well beaten to 80mm by using wooden hand beaten of weight not exceeding 2 kg hand beating during liberally with lime water and a small proportion of solution prepared by soaking water in dry nut of kadukka and giving required slope and thickness of roof etc. as directed by the departmental officers.

4791

-

-

... More
Finishing the top of roof slab with one course of pressed tiles 23cm x 23cm x 2cm using cement mortar 1:3 (One of cement and three of P-sand) mixed with water proofing compound at 2% weight of the cement and pointed with the same l mortar etc., complete in all respects.

4947

-

-

... More
White washing two coats using clean shell lime including the cost of lime, gum, brushes and scaffolding etc., complete in all respects as directed by the departmental officers

266008

-

-

... More
Painting the walls with two coats of approved cement paint over one coat of primaring coat of cement paint including the cost of paint, brush, scaffolding etc., complete in all respect as directed by the departmental officers.

83654

-

-

... More
Suplying and fixing UPVC (Un - Plasticized Polyvinyl Chloride ) louvered ventilators of from the profile the size of outer frame 60mm x 58 mm and shutter profile are reinforcement with GI/ 1 mm 125 GSM and 100% corrosion free, the profiles are profile are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with over all edges of frame and shutter the shuttter will be provided with Espag multi power point locks and also it operates as handle. The corners and joints should be welded and cleaned .Radiations free pin headed plain or brown colour glass 4mm thick should be provided to the shutter and it should not allow leakage of water even at most ranging storms and should have key lockable action ,security protective hinges ,strong locking systems and as per size for arresting noise and energy loss.The connecting mechanism netween sash and outer frame that enables opening of the window . The window should be fixed be fixed to the wall with 100% packing with screws and silicon packing all round the frames .The Ventilators should be got approved from the Executive Engineer before use on work.

2142

-

-

... More
Supplying of Door Frame of following Size with required dimensions of size~ 100 mm x 75 mm, with groove of size ~ 30 mm x 20 mm for resting the door shutter & chamfer finish at front using CRCA pressed steel box section 18 gauge or 1.25mm thick for door frames including providing holes and fixing wooden blocks for fixing fixtures and fittings and 4 nos of hold fast using the iron angle of 15cm length with split ends one coat of red oxide primer / Chemical arcylic, Fabrication and Supply of 35mm thick solid core flush door with teak ply on one side and commercial ply on other side with teak wood liping al round with iron oxidized hinges, tower bolts 12" 2 nos with receiver, Al drop 30 cm and handle 1 no for door of following size

-

-

-

... More
For 0.90m X 2.10 m

1435

-

-

... More
For 1.00m X 2.10 m

1500

-

-

... More
Supplying and fixing of solid pvc door shutter using 19gauge 19mmM.S square tube for styles outer frames15mm for M.S square tubes for toplock top and bottom rails. the steel tubes shall be covered with 5 mm thick solid pvc sheets shutter for panelling shall rigidity fixed in positition including necessary furniture fittings.THe over all size of styles shall be 50mmX30mm. The over all styles of top rails bottom rails shall be 75mmX 30mm. The over all size of framesshall be 50mmx 45mm with suitable rebate shutters.size 750X 1980mm.

4639

-

-

... More
Suplying and fixing UPVC (Un - Plasticized Polyvinyl Chloride) Windows of casement type (open) from the profile the size of outer frame 60mm x 58 mm and shutter profile are reinforcement with GI/ 1 mm 125 GSM and 100% corrosion free, the profiles are profile are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with over all edges of frame and shutter the shuttter will be provided with Espag multi power point locks and also it operates as handle. The corners and joints should be welded and cleaned .Radiations free pin headed plain or brown colour glass 4mm thick should be provided to the shutter and it should not allow leakage of water even at most ranging storms and should have key lockable action ,security protective hinges ,strong locking systems and as per size for arresting noise and energy loss. The connecting mechanism between sash and outer frame that enables opening of the window . The window should be fixed be fixed to the wall with 100% packing with screws and silicon packing all round the frames .The window should be got approved from the Executive Engineer before use on work.

5917

-

-

... More
Supplying and fixing cuddappah slab planks 20mm thick of various size (both sides polished) for cupboard planks in all floors including cost of slab, labour charges for fixing in proper position with necessary bearing packing with Cement Mortar and finishing etc. complete in all respects as directed by the departmental officers.

8903

-

-

... More
Providing Ellis Pattern flooring 20mm thick (Ellis pattern) with layer of cement concrete 1:3 (one of cement and three of hard broken stone) (No sand) using hard blue granite chips of size 3mm to 10mm and surface rendered smooth over RCC slab including supplying and fixing 20mm dia GI pipe outlet etc., complete in all respects.

10654

-

-

... More
Plastering the top of flooring with CM 1:4 (One of cement and four of P-sand) 20mm thick with including finishing smooth proper setting, curing etc complete in all respects as directed by the departmental officers.

2751

-

-

... More
Painting the new wood work with two coat of first class synthetic enamel paint of approved quality and colour in addition over the existing primer coat including the cost of paint patty brushes and scaffolding etc. complete as directed by the departmental officers.

14073

-

-

... More
Paving the floor with best quality of stain free nano polish Vitrified tiles of size 600mm x 600mm x 8mm thick and laying over bed of cement mortar 1:3( one of cement and three of M-sand) , 20mm thick including cutting and laying and pointing with white cement with colouring pigment to match the tile, colour and providing skirting to the required size etc complete in all respect as directed by the departmental officers. (The make and brand of the tiles should be got approved by Executive Engineer before use on works).

36743

-

-

... More
Flooring with ceramic tiles of approved quality,colour and design anti skid type joint free of size 305mm x 305mm x 6mm thick of approved make, quality and colour in all floor over base layer of cement concrete 1:3 , (one cement and three M-sand )20mm thick and laid straight aligment and pointed neatly with colour cement @ .40 kg/m2 in position as per standard specification and complete is all repsect as directed by the departmental officers.

3398

-

-

... More
Dadooing the walls with colour glazed tiles of minimum 15cm x 15cm x 6mm laid in cement mortar 1:2 (one of cement and two of M-sand) 10mm thick and pointing with white cement using 0.40 kg/m2 icluding finishing the joint and pointing flush with tiles surface etc.. complete in all respect as directed by the departmental officers.

17495

-

-

... More
Painting the new iron works of door with one coat of firstclass synthatic enamel paint of approved quality and colour including the costof paint brushes and scaffolding etc., complete as directed by the departmental officers.

12262

-

-

... More
Supplying and fixing in Position White / Colour Glazed model European water closet of best quality and approved make with 100mm "P" or "S" trap connecting with CI pipe of 100mm dia / PVC pipe of 110mm dia, double flapped rigid PVC black seat and seat cover with CP brass hinge including cost of white cement for packing, spun yarn , teak wood plug , brass screws, etc., including supplying and fixing 10 liters capacity PVC / 12.5 liters capacity porcelin low level flushing tank with a pair of CI brackets, etc., complete with all fitting , such as,15mm brass ball valve with polythene float with brass handle , union coupling connected by means of 40mm White PVC flush hand using indian adopter joint including all internal fitting, such as, 15mm bras connections ,15mm GM wheel valve ,15mm bras nipple (2 nos), 15mm nylon connections,TW plugs, screws and also giving necessary connection to the PVC pipe and painting the CI brackets with 2 coats of approved paint over one coat of red oxide primer, dismantling the masonry and re-doing the dismantled masonry to original condition, etc., complete complying with standard specification. (The EWS and flushing tank with all accessories should be got approved by the Executive Engineer before use on works) Floor Fitting

70

-

-

... More
Supplying and fixing of Oriya type water closet 45cm with 'P' or 'S' trap (White glazed) earthern ware best (IN ALL FLOORS OTHER THAN GROUND FLOOR) including concrete packing fixing filling the sink portion with stone jelly lime concrete 32:12 1/2 (Thirty two parts of broken stone jelly and twelve and half of lime (no sand) using 20mm size broken stone jelly and plastering the top of flooring with cement mortor 1:4 (one of cement and four of sand) 12mm thick including plastering the sides of sink portion in cement mortor 1:3 (One of cement and three of sand) 12mm thick mixed with water proofing compound 4 lbs/cft in cement applying one coat of britex solution including curing for the sides and bottom of the sink portion, curing etc., complete as directed by the departmental officers

1430

-

-

... More
Supply and fixing of 110mm dia PVC rain water down fall pipe 4kg/cm2 with 2 nos of PVC bend & pipes with necessary clamps couplers gratings teakwood plug etc., complete including fixing in proper position with solvent cement etc., including making good of the dismantled portion complete to the relevent standard specification etc., complete in all respects as direrct by the departmental officers SWR pipe type A

4974

-

-

... More
Supplying and fixing of 110 mm & 75mm dia UPVC soil pipe of 6kg/cm2 of approved quality ISI 13592/1992 with ISI Monogram packing the joints with hempyarn and cement including fixing into walls with necessary wooden plugs and holding down clamps, dismantling and making good of the dismantled portion with necessary connection to the sanitary fittings painted with two coats of anti-corrisive paint including testing etc., complete in all respects.

-

-

-

... More
110 mm UPVC pipe

5660

-

-

... More
75 mm UPVC pipe

11318

-

-

... More
Supplying, laying the following dia UPVC soil pipe with IS 13592/1992 (Type B) monogram including jointing with solvent properly to gradient necessary connection to the sanitary fittings in water closet room and bath room including texting etc complete in all respects as directed by the departmental officer.

-

-

-

... More
110 mm Dia of Pipe Type B

1452

-

-

... More
75 mm Dia of Pipe Type B

3325

-

-

... More
Supplying, laying the following UPVC SWR specials (IS14735/1992) including jointing with solvent cement, properly to gradient including excavating and refilling the trenches and curing the cement joints and testing etc., complete in all respects as directed by the departmental officers.

-

-

-

... More
110 mm dia UPVC Vent cowl

130

-

-

... More
110 mm dia UPVC Shoe

130

-

-

... More
110mm Dia UPVC bend

1430

-

-

... More
110mm Dia Y with door.

1430

-

-

... More
75mm Dia UPVC bend.

2134

-

-

... More
75mm Dia UPVC Shoe

194

-

-

... More
75mm Dia Y with door.

2860

-

-

... More
75mm dia UPVC vent Cowl

194

-

-

... More
Supplying and fixing PVC Nahini trap / Floor Trap with PVC grating 100mmx75mm over the bed of brick jelly concrete and fixing in position etc., complete in all respect as directed by departmental officers.

3224

-

-

... More
Supplying, laying and jointing UPVC pipes of approved quality and best variety conforming to BlS of the following dia including cutting, threading and fixing UPVC specials using UPVC adhesives (but excluding cost of such specials) and fixing into wall with teak wood plugs, SS clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges upto 4 metre height above ground level, etc., complete complying with standard specifications. The UPVC pipes shall be got approved by Executive Engineer before use on works as per IS 4985

-

-

-

... More
25mm dia UPVC Pipe

20385

-

-

... More
20mm dia UPVC Pipe

11856

-

-

... More
40mm dia UPVC Pipe

4721

-

-

... More
Supplying of UPVC pipe specials of approved quality suitable to pipe as per table II IS 14735: 1999 at site of work etc complete in all respects as directed by the departmental officers.

-

-

-

... More
25mm dia UPVC Coupler

5928

-

-

... More
25mm dia UPVC Elbow

5928

-

-

... More
25mm dia UPVC Tee

2964

-

-

... More
25mm dia UPVC hex nipple checknuts with washer

4446

-

-

... More
25mm X 20mm Reducer

4446

-

-

... More
15mm dia screw down tap heavy type

4446

-

-

... More
40mm dia Elbow

520

-

-

... More
40mm X 32mm Reducer Tee

130

-

-

... More
32mm dia UPVC Tee

130

-

-

... More
20mm dia UPVC Elbow

5928

-

-

... More
20mm dia UPVC Coupler

5928

-

-

... More
20mm dia Tee

4446

-

-

... More
Supply of 40mm dia pipe GI pipes at inlet and ISS 1239 (medium) screwed at both ends and socketed both ends etc complte in all respect as directed by departmental officers.

585

-

-

... More
Labour charges for laying, fixing,jointing G.I pipes and specials for the following dia meter including cutting and threading the pipes wherever necessary and jointing with white lead, spun yarn, earthwork excavation for laying the pipes wrapping with tarred tape and refilling the trenches where the pipes are laying under ground complete.

-

-

-

... More
40mm dia GI Pipe - Horizontal

260

-

-

... More
Labour charges for cutting and jointing the 40mm dia pipe GI pipe Rigid pipe using required solvent cement with necessary specials the following die above G.L. Including fixing into wall necessary T.W. Plugs screws etc., complete in all respects as directed by departmental officers.

-

-

-

... More
40mm dia GI Pipe - Vertical

325

-

-

... More
Supplying of GI and GM specials confirming to ISI etc.,complete in all respects as directed by departmental officers.

-

-

-

... More
40mm dia GI Elbow

520

-

-

... More
50mm X 40mm dia GI Reducer

130

-

-

... More
25mm GM Wheel valve

850

-

-

... More
40mm GM Gate valve

130

-

-

... More
Construction of Inspection chamber 0.60M x 0.60M for the following depth brick jelly cement concrete 1:5:12 1/2 (One of cement and five of M- and twelve and half of broken brick jelly) using 40mm size brick jelly 15cm thick for foundation 23cm thick Fly Ash brick masonry wall in CM 1:5 (One of cement and five of M-sand) using Fly Ash bricks of size 23x11x7cm and inside plastering with 1:3 (one of cement and three of P-sand) 12mm thick including channeling, benching etc. and top covered with SFRC (medium duty) cover slab and fixing in position and necessary earth work excavation, refilling the sides of foundation in all soils except hard rock requiring blasting etc. complete in all respects as directed by the departmental officers. (Average Depth of .60m)

325

-

-

... More
Construction of Gully chamber 0.23 x 0.23 x 0.30m following depth with brick jelly concrete 1:5:12 1/2 using 40mm size brick jelly 15cm thick for foundation,23cm brick work, masonry wall in CM 1:5 (one of cement and five of sand) using II class ground moulded chamber burnt bricks plastered with CM 1:3 12mm thick including channelling benching and top covered SFRC COVER SLAB but including earth work excavation refilling the sides of foundation in all soils expect hard rock refilling plastering etc., complete in all respects in all respects as directed by the departmental officer.

130

-

-

... More
Supplying & fixing the MS Grill gate of various sizes as per departmental specification including painting with one coat of primer etc. complete in all respects as directed by the departmental officer

184278

-

-

... More
Supplying and fixing in position best quality approved make cudappah sink of size 600 X450 X200mm including cost of 32mm dia ‘B’ class G.I waste pipe & 32mm dia CP waste coupling. Brass Nipple, Plug and chain and testing for leakage etc., complete complying with standard specifications. (The sink and accessories should got approved by the Exe.Engr. Before use on work.)

1500

-

-

... More
Wiring with 2x1.5sqmm PVC insulated single coreunsheathed copper conductor cable of 1100V gradewith ISI mark confirming to IS: 694/1990 in suitablePVC rigid pipe of 1.8mm thick with ISI mark concealedin wall and ceiling with PVC accessories in flushwith wall including the cost of cable, pvc pipe andspecials, ceiling rose, flush type 5ams SP markswitch, PVC junction box, 16gauge MS switch box100mm x 100mm x 75mm covered by laminatedhylem sheet 3mm thick, cement, labour and makinggood of concealed portion with suitable colour forconcealed LIGHT point.

10510

-

-

... More
Wiring with 2x1.5sqmm PVC insulated single coreunsheathed copper conductor cable of 1100V gradewith ISI mark confirming to IS: 694/1990 in suitablePVC rigid pipe of 1.8mm thick with ISI mark concealedin wall and ceiling with PVC accessories in flush withwall including the cost of cable, pvc pipe and specials, ceiling rose, flush type 5ams SP mark switch, PVCjunction box, 16gauge MS switch box 300mm x200mm x 75mm covered by laminated hylem sheet3mm thick, cement, labour and making good ofconcealed portion with suitable colour for concealed FAN point.

3005

-

-

... More
Supply and fixing water tight Bulk head fitting(heavy type) with guard suitable for 100/60W bulb including the cost of bulb, necessary connection cost of materilas etc. complete in all respects as directed by the departmental officers

315

-

-

... More
Supplying and fixing of 5 A /15A 3 pin flush type wall socket with15A flush type switch concealed in suitable MS box in flush with wall and covered with 3mm thick hylem sheet including cost of wall socket, switch and labour charges fo wall cutting, grouting, flushing and making good, painting with primary and finishing coat for MS box etc., complete in all respects as directed by the departmental officers.

3010

-

-

... More
Wiring with 2 x1.5sqmm PVC insulated single core unsheathed copper conductor cable of 1100V grade with ISI mark insuitable PVC rigid pipe 2mm thick concealed for FOR 5 AMPS 3 PIN C.S.PLUG POINT AT SWITCH BOARD ITSELF including cost of cables, PVC pipe and special, brass screws, flush type 5amp S.P.Mark switch, labour and making good of the concealed portion with suitable colour for concealed PVC plug point etc., complete in all respects as directed by the departmental officers.

1510

-

-

... More
Supplying and fixing of 5 A 3 pin and 2 pin combined flush type wall socket with 5 A flush type switch concealed in suitable MS box in flush with wall and covered with 3mm thick hylem sheet including cost of wall socket, switch and labour charges complete in all respects as directed by the departmental officers.

4510

-

-

... More
Supply and run off 2 of 2.50 sq.mm PVC insulated single core unsheathed copper conductor cable of 1100V grade with ISI mark confirming to IS:694/1990 with continuous earth connection by means of 1.50 sqmm PVC insulated single core unsheathed copper conductor cable confirming to IS:694/1990 in suitable PVC rigid pipe 1.8mm thick concealed on walls and ceiling for mains including the cost of cable, PVC pipes and specials, cement, brass screws, TW plugs, saddles and labour etc., complete in all respects as directed by the departmental officers.

75000

-

-

... More
Earthing as per ISI Specification with an earthelectrode of 2.1mt class 'B' GI pipe of dia not less than40mm and with 20mm dia copper earth flat of size125mm x50mmx6mm, with funneling arrangementusing charcoat, common salt, G.I.reducer, checj nutsetc., and mansonry workand providing RCC coverslab 38mm thick for the Brick mansory including costof steel and fabrication of reinforcement etc.,complete in all respectes as directed by thedepartmental officers. (SD 233)

16

-

-

... More
Supplying and run off 8 SWG copper wire on walls or below ground level with necessary 'U' nail,earth work excavation and refilling inclusive of the costll materials etc complete in all respects as directed by the departmental officers.

460

-

-

... More
Supplying and fixing of 4 way( 6 Module) with 4No's of 6A - 16 A MCB & 32 A DP Isolator includind labour charges etc., complete in all resspcets as directed by the departemental officers

1500

-

-

... More
Supplying and erecting pull and push type rolling shutter with ISI make of approved size and section using 18 GI sheet. The shutter be painted with one coat of red oxide primer and inclusive of hood covers, transportation charges etc complete in all respect as directed by the departmental offices.

25

-

-

... More
Design, Engineering, Supply, Fabrication, Erection, Testing, commissioning and handing over of 1 no of 15 passenger stretcher lift as per the following specifications including taxes and duties.(Gearless lift with machine room) 1.Location:East Cemetery Road, 2.No of lift: 1 no. (Gearless), 3.Type of lift: stretcher lift, 4.Capacity of lift: 15 persons / conforming to 14665 (part 1) 2000, 5.Speed: 1.0 M / Sec, 6.Type of drive: V3F drive with enhanced ride comfort and near zero level functions, 7.No of floors: S+11 Floor, 8.Total travel: 3.0 mts x 12 Landing = 36 mts, 9.Leveling accuracy: high level accuracy with smooth and jerk free stopping, 10. Construction of CAR: No. 4 hardened sheet high quality stainless steel car and hand rail granite flooring and Perspex false ceiling, 11. Position of machine: directly above the lift well., 12. No of landing service: One in the front side- 1 no, 13. No. of car entrance: one in the front side only, 14. Car entrance door: power operated automatic V3F drive center opening sliding SS door, 15. Landing entrance door: power operated V3F drive center opening sliding SS door with provision for emergency exit key at all landings, 16.Lift well :As per structural design conforming to IS 14665(part1) 2000 to be constructed by the Building contractor, 17.Lift pit depth: conforming to 14665 (part 1)2000, 18. Car inner size, Total weight of person and Overhead height : conforming to 14665 (part 1)2000, 19. Car clear opening:conforming to 14665 (part 1)2000, 20.Lift machine room size: as per ISI 14665 (part 1) 2000 to be constructed by the building contractor, 21. Power supply: 400 / 440 v three phase 50 Hz AC supply for power and 230 V 50 Hz single phase power supply for light, 22.Control: micro computer (micro processor):based simplex collective control with / without attendant, 23. Car fittings: CFL lighting with 1 no 300 mm sweep cabin fan, 24. Lift well: RCC construction with brick masonry to be constructed by the building contractor, 25. Induction: UP / DOWN digital direction and floor position indicator for all landings in all floors and inside the car, 26.Emergency alarm bell: battery operated bell to be provided with automatic charging device, 27.Emergency light: battery operated light to be provided with automatic charging device, 28.Fire mans switch: to be provided at the GF, 29. Minor builder works: to be provided by the lift contractor.(S&F of bulk head, 5A switch, light point, wiring 2 of 2.5 sqmm at every floor and machine room lighting, 4way/8way/12 way TPN DB) and other requirements, 30. Scaffoldings: to be provided by the lift contractor. 31. Sill angles and facia plates: SS to be provided by the lift contractor. 32. Steel for lift machinery: to be provided by the lift contractor.33. Servicing and maintenance: free comprehensive servicing and maintenance for one year Guarantee period to be provided by the lift contractor. 34. Automatic rescue device: to facilitate the landing of the nearest floor at the time of power failure this shall consist of suitable battery system with charger inverter under voltage protection system etc. complete with all accessories and single phase preventor specifying to IS norms, 35. Provision for intercom with phone: to be provided by the lift contractor, 36.Lift license: preparation of drawings payment of charges to CEIG and insurance policy for both lift & body if any and obtaining CEIG approval for the lift as per lift act should be done by the lift contractor, 37. Floor position announcer: to be provided by the lift contractor. 38.Special features a) Infra red door sensor with full height screen, b) Full width half height rear panel mirror, c)Tubular SS hand rail in car, d) Stainless steel signal features, e) Vandal proof SS button with SS cover, f) SS door frames for landing doors, g) V3F door operator, h) Call register signal, i) Stainless steel facia plates for car operating panel and landing fixtures, j) Steel ladder for lift machine room, k) On / off switch for fan and light, l) Over load warning indicator with audio announcer, m)Voltage stabilizer for control circuits, n)Braille button, o) Precautionary measures etched in SS plate, 39.Over speed governor phase failure and phase reversal relay alarm bell T guide brackets for car and counter weight rubber padding under the winding unit motor of adequate capacity signal reduction worm gear electromagnetic brake with compression springs car safety gears buffers electro mechanical locks emergency key side supporting angles motor over load protection devices final limit switch main suspension ropes counter weight lifting joist for mounting the machineries, 40. Guarantee: guarantee at least for one year for the material and workman ship of equipments should be offered by the lift contractor. 41. Site testing in accordance with IS 14665 should be carried out at the time of handing over to the user department, 42. Supply operation and maintenance manual and necessary tools for operation and a set of Spare parts required for one year, 43.All the features as per differently abled person Act should be provided, 44. 2 hrs.fire retardent landing doors Stretcher Lift 15 person capacity

5

-

-

... More
Design, Engineering, Supply, Fabrication, Erection, Testing, commissioning and handing over of 1 no of 08 passenger lift as per the following specifications including taxes and duties.(Gearless lift with machine room) 1.Location:East Cemetery Road, 2.No of lift: 1 no. (Gearless), 3.Type of lift: Passenger lift, 4.Capacity of lift: 08 persons / conforming to 14665 (part 1) 2000, 5.Speed: 1.0 M / Sec, 6.Type of drive: V3F drive with enhanced ride comfort and near zero level functions, 7.No of floors: S+11 Floor, 8.Total travel: 3.0 mts x 12 Landing = 36 mts, 9.Leveling accuracy: high level accuracy with smooth and jerk free stopping, 10. Construction of CAR: No. 4 hardened sheet high quality stainless steel car and hand rail granite flooring and Perspex false ceiling, 11. Position of machine: directly above the lift well., 12. No of landing service: One in the front side- 1 no, 13. No. of car entrance: one in the front side only, 14. Car entrance door: power operated automatic V3F drive center opening sliding SS door, 15. Landing entrance door: power operated V3F drive center opening sliding SS door with provision for emergency exit key at all landings, 16.Lift well :As per structural design conforming to IS 14665(part1) 2000 to be constructed by the Building contractor, 17.Lift pit depth: conforming to 14665 (part 1)2000, 18. Car inner size, Total weight of person and Overhead height : conforming to 14665 (part 1)2000, 19. Car clear opening:conforming to 14665 (part 1)2000, 20.Lift machine room size: as per ISI 14665 (part 1) 2000 to be constructed by the building contractor, 21. Power supply: 400 / 440 v three phase 50 Hz AC supply for power and 230 V 50 Hz single phase power supply for light, 22.Control: micro computer (micro processor):based simplex collective control with / without attendant, 23. Car fittings: CFL lighting with 1 no 300 mm sweep cabin fan, 24. Lift well: RCC construction with brick masonry to be constructed by the building contractor, 25. Induction: UP / DOWN digital direction and floor position indicator for all landings in all floors and inside the car, 26.Emergency alarm bell: battery operated bell to be provided with automatic charging device, 27.Emergency light: battery operated light to be provided with automatic charging device, 28.Fire mans switch: to be provided at the GF, 29. Minor builder works: to be provided by the lift contractor.(S&F of bulk head, 5A switch, light point, wiring 2 of 2.5 sqmm at every floor and machine room lighting, 4way/8way/12 way TPN DB) and other requirements, 30. Scaffoldings: to be provided by the lift contractor. 31. Sill angles and facia plates: SS to be provided by the lift contractor. 32. Steel for lift machinery: to be provided by the lift contractor.33. Servicing and maintenance: free comprehensive servicing and maintenance for one year Guarantee period to be provided by the lift contractor. 34. Automatic rescue device: to facilitate the landing of the nearest floor at the time of power failure this shall consist of suitable battery system with charger inverter under voltage protection system etc. complete with all accessories and single phase preventor specifying to IS norms, 35. Provision for intercom with phone: to be provided by the lift contractor, 36.Lift license: preparation of drawings payment of charges to CEIG and insurance policy for both lift & body if any and obtaining CEIG approval for the lift as per lift act should be done by the lift contractor, 37. Floor position announcer: to be provided by the lift contractor. 38.Special features a) Infra red door sensor with full height screen, b) Full width half height rear panel mirror, c)Tubular SS hand rail in car, d) Stainless steel signal features, e) Vandal proof SS button with SS cover, f) SS door frames for landing doors, g) V3F door operator, h) Call register signal, i) Stainless steel facia plates for car operating panel and landing fixtures, j) Steel ladder for lift machine room, k) On / off switch for fan and light, l) Over load warning indicator with audio announcer, m)Voltage stabilizer for control circuits, n)Braille button, o) Precautionary measures etched in SS plate, 39.Over speed governor phase failure and phase reversal relay alarm bell T guide brackets for car and counter weight rubber padding under the winding unit motor of adequate capacity signal reduction worm gear electromagnetic brake with compression springs car safety gears buffers electro mechanical locks emergency key side supporting angles motor over load protection devices final limit switch main suspension ropes counter weight lifting joist for mounting the machineries, 40. Guarantee: guarantee at least for one year for the material and workman ship of equipments should be offered by the lift contractor. 41. Site testing in accordance with IS 14665 should be carried out at the time of handing over to the user department, 42. Supply operation and maintenance manual and necessary tools for operation and a set of Spare parts required for one year, 43.All the features as per differently abled person Act should be provided, 44. 2 hrs.fire retardent landing doors SPassenger Lift 08 Person Capacity

8

-

-

... More
Earthing arrangements with GI Earth Plate including charcoal and salt with necessary excavation in all soils and to full depth as may be required and masonry work, re-filling the sides of foundation with excavated earth as per the standard specification etc complete in all respects as directed by the Departmental Officers

26

-

-

... More
Supply and laying of 31/2 x 50 sq.mm pvc armoured Aluminium LT UG cable of approved brand having ISI mark on post or wall with M.S clamps etc complete in all respects as directed by the Departmental Officers

260

-

-

... More
Supplyandrunof 25mmx6mmGI strip FlatDownCondutorwith necessaryclamps/supportsonwall / floor /groundforearth connection etc complete in all respects as directed by the Departmental Officers

1040

-

-

... More
Supply, erection testing, commissioning and handing over of 1No,58.5 KVA diesel generator set 0.80 P.F, 3phase, 415v/420 Volts, 50c/s, 1500 RPM complete in all respects as detailed below.CPCB IV complaint DG set . A.Engine Liquid Cooled / Water cooled diesel engine suitable for generator application with a shaft out put of ( 84HP/50KW with respect to the make of generator) suitable at 1500 RPM under NTP conditions as per BSS 5414-ISO 10000. The engine shall comprise the following standard scope of supply: (Make Kirloskar/ Cummins/ Ashok Leyland/ Greaves/ Equivalent) 1) Dry type Air cleaner 2) Expansion bellow 3) Radiator, radiator fan and mounting 4) Air to air charge cooler 5) Exhaust gas turbo charger 6) Lube oil cooler and lube oil filter filter 7) Fuel filter (pre and micro) 8) In-line mono-block fuel injection pump with governor and fuel feed pump 9) Mechanical / Electronic governor 10) 12V / 24V battery charging alternator 11) 12V / 24V Volt electric starter motor 12) Engine test certificate 13) Residential Mufler 14) Fly wheel with starter ring. (B)ENGINE INSTRUMENT PANEL MOUNDING Engine instrument panel /mounted engine control panel consisting of ON/OFF/START/KEY, lube oil pressure gauge, oil temperature gauge, high water temperature gauge and electronic hour Mtr and RPM indicator. Safety system of Engine: The engine shall trip for the following conditions with Visual alarm device. 1) Low lubricating oil pressure 2) High water temperature 3) Vee- belt failure and over speed 4) Low battery indicationThe Engine should be capable of Providing 10% over load for one hour for every 11 hours Continuous Running at full load. (C) ALTERNATOR: 58.5 KVA capacity of brushless alternator AC 3 phase 50 c/s 415 volts, 0.8 PF 1500 RPM under NTP conditions confirming to IS 13364 (part II) 1992 to be means of coupling. (D)ACOUSTIC ENGLOSURE : Acoustic enclosure shall be powder coated and fabricated out of 16 SWG CRCA MS Sheet . The silent canopy shall be of nut bolt type construction. Critical processes of punching are done on CNC machines to maintain dimensional accuracy of holes within 0.1 mm . Power coating is done after seven – tank surface preparation process of sheet metal canopy panel and doors shall have inside lining of Fire Retardant 64 Kg / Cu Mt Density Mineral wool of 100 mm thick ness as acoustic material . Four hinged doors shall be provided to canopy. The emergency stop should be available on the enclosure panel The Engine Manufacturer of the Engine provided for diesel Generator sets mounted inside and should be to the satisfaction of inspection / testing authority concern. SURFACE TREATMENT – PAINTING The enclosure surface hall be suitably treated for degreasing . degusting and posphating . The canopies are passed thought seven – tank treatment thoroughly. ADDITIONAL FEATURES OF CANOPIES :- Canopy fabricated on CNC machine with dimensional accuracy of 0.1 mm so as to increase its durability . special designed supporting rips / structures are used in canopies so as to give sturdiness and to reduce the vibrations of the DG sets if any. WORLD CLASS COOLING PACKAGE:- Canopies shall have cooling package for which it can also perform at 45 deg c / ambient Temperature. No grouting required on the ground , only a level surface capable of with standing the DG weight . Lifting hooks shall be provided for the acoustic enclosure , which should unloaded independent of the DG set . the Gen set base frame shall also provided with hooks for unloading. TEMPERATURE RISE INSIDE THE CANOPY Canopies shall be designed so as to maintain the temperature difference between ambient and air inlet at air cleaner with the enclosure well within 5 – 7 Degree Centigrade.(G)BASS FRAME: Base frame should be fabricated MS Channel sheet Metal , The base frame is rigged in construction and designed for mounting engine and brush less alternator closely coupled . with cross members mounted on AVM . The base frame shall have provision for mounting of acoustic enclosure on it . The supply of Gen set includes loading , unloading and transportation charges. 6) Fuel Tank 100 Ltrs. and above (with respect to the make of generator) Removable Fuel tank shall be fabricated out of 14 SWG CRCA MS sheet and is part of base frame. It is duly painted and fitted with inlet an outlet connections and mechanical fuel gauge. Fuel tank can be easily removed for cleaning or any maintenance.. 7) Battery 12V 100 AH battery-1 NO

7

-

-

... More
Supplying and laying the rubber Moulded Hydraulic Pressed machine made 63mm thick inter locking concrete paver block made out of M20 grade concrete of approved design in colour over the bed of M-sand filling including labour for laying, hand packing and compaction etc complete in all respects as directed by the departmental officers

1486

-

-

... More
Earth work excavation for foundation with all leads and lifts in all soils and subsoil’s to the required depth as may be directed except hard rock requiring blasting inclusive of shoring strutting and bailing out water wherever necessary refilling the sides of foundation with excavated earth in layers of 15 cm thickness well consolidated depositing the surplus earth in places shown and leveling the site with all initial leads and lifts etc complete complying with relevant standard specification etc complete in all respects as directed by departmental officers.

88

-

-

... More
Cement concrete 1:3:6 (one of cement, Three of M-sand and Six of hard broken stone) using 20mm size hard broken stone inclusive of shoring, strutting, bailing out water, ramming, curing, etc complete in all respect as directed by the departmental officers.

106

-

-

... More
Sectioning the site including cutting and filling the undulations upto 15cm thick and levelling etc., complete in all respects as directed by the departmental officers.

2232

-

-

... More
Providing and laying sand gravel mix 1:1 (one of sand and one of gravel) to the 150 mm thickness to be laid two layers to give a minimum soaked CBR value as per IRC 37-1984 including cost and conveyance of sand and gravel to the work site and stacking them to the standard departmental metric gauge , labour charges for mixing the required quantities of sand and gravel spreading, watering and compacting the mix in layers of thickness not exceeding 10mm compacted thickness by 80-100KN power roller rolling to achieve the required proctor density including the labuor charges for mixing spreading and all other tools and plants and other incidental charges., complete as per standard specification.

335

-

-

... More
Providing and laying water bound macadam for 75mm consolidated thickness with Grade II metal confirming MOST specification using 0.41m3 of 63mm, 39 m3 of 53mm and 0.2m3 of 45mm IRC metal with 0.24m3 of gravel for blindage for 10 sqm including the cost and conveyance of material from approved quarry to road site and stacking them to the departmental gauge for pre-measurement, labour charges for spreading in layers, hand packing to camber, dryrolling, watering, blindage including cost and conveyance for good water, forming edge bunds, slurrying and consolidation by power roller hire, running slurrying and fuel charges for power roller, water sprinkler and other tools and plants employed for the work including all other incidental charges such as barricading and providing danger lights etc.complete as per standard specification of 404 of MOST.

2232

-

-

... More
Providing and laying water bound macadam for 75mm consolidated thickness with grade III metal confirming MOST specification using 0.36 of 53 mm , 0.35 cum of 45mm and 0.29 cum of 26.5mm IRC size HBGmetal with 0.24 cum of gravel as screening whose P.H.Value is less than 6 for blindage for 10 sqm including cost and conveyance of material the departmental gauge for premeasurement labour to camber, dryrolling, watering, blindage including cost and conveyance for good water, forming edge bunds,slurrying and consolidation by power roller to achieve the specified compaction including all labour water sprinkler and other tools and plants employed for the work including all other incidental charges such as barricading and providing danger lights etc.completeas per standard specification of 404 of MOST

2232

-

-

... More
Applying tack coat over un primed WBM surface using 4kg of bitumen Emulsion for 10m2 including cost of bitumen conveyance to site handing charges including labour charges for brushing, cleaning and preparing the surface for laying the coat and labour charges for applying the required quantity of bitumen including hire and fuel charges for tools and plants etc., complete in all respects as directed by the depaprtmental officers

2232

-

-

... More
Providing and laying of open graded premix carpet with seal coat TYPE - "B' for 20mm consolidated thickness using 0.18 m3 of 13.2mm IRCsize HBG crusher metal and 0.09m3 of 11.2mm IRC size HBG crusher metal with 14.60 kg of bitumen of 80\100 grade for pre mixing for 10 m2 of premix carpet and 0.06m3 of clean good sand with 6.8 kg of bitumen for 10 m2 for seal coat Type - B including cost and conveyance of metal and chips to the work site and stacking them to departmental metric gauge for premeasurement including cost of bitumen and all taxes payable which will be procured and supplied by the contractor himself including cost of conveyance of 80/100 grade bitumen to work site and all incidental charges such as storage, handling charges etc. including mixing the materials in the mini hot mix plant for premix carpet only including spreading and consolidation by power roller, rolling including labour, hire and fuel charges for mini hot mix plant and other tools and plants employed etc. cost of all materials labour charges etc. complete as per clause 509 of Most specification.

2232

-

-

... More
Providing rain water harvesting in all soils and sub soils with RCC well rings of size 0.90m internal dia and 5cm wall thickness to the required depth of 0.90m and providing circular RCC perforated cover slab of 1m dia and 5cm thickness laid over the top most well rings excluding cost of steel fabrication of reinforcement grills in position at site of work for circular rings and for perforated cover slab in a places as directed by the departmental officers including necessary earthwork excavation of 1m dia to a depth of 0.90m and filling inside the well rings with 40mm size hard broken stone jelly without causing any damages to the rings etc., complete in all respects as directed by the departmental officers.

130

-

-

... More
Supplying and laying of UPVC -non pressure pipes as per IS 15328/2003 [SN8-SDR (S 16.5)] and laying and jointing of UPVC pipes to the proper grade and aligment as indicated in drawing / design and hydraulically testing of the pip[e line. The rate shall include cost of all necessary jointing materials testing charges with water conveyed within a lead of 1km, labour etc. complete in all respects as directed by the departmental officers.

-

-

-

... More
160 mm dia UPVC Pipe

1699

-

-

... More
200mm Dia UPVC Pipe

623

-

-

... More
Construction of circular RCC manhole of 1.2m internal dia with Reinforced cement concrete wall of 15cm thick and base slab of 15cm thick of 1:4:8 proportion (One of cement, four of M-Sand and eight of hard broken granite stones ) using 40mm gauge hard broken granite stones including the cost of steel and fabrication of reinforcement grills in position shutterring centering etc., including channeling benching etc., and top covered with extra heavy duty cover slab SFRC slab with frame 600mm(clear opening) including casting and fixing in position and necessary earth work excavation, refilling the sides of foundation in all soils except hard rock requiring blasting etc., complete in all respects as directed by the departmental officer.

-

-

-

... More
0.90m Depth

30

-

-

... More
1.20m Depth

10

-

-

... More
1.50m Depth

10

-

-

... More
2.00m depth

10

-

-

... More
Construction of Inspection chamber 0.60M x 0.60M for the following depth brick jelly cement concrete 1:5:12 1/2 (One of cement and five of M- and twelve and half of broken brick jelly) using 40mm size brick jelly 15cm thick for foundation 23cm thick Fly Ash brick masonry wall in CM 1:5 (One of cement and five of M-sand) using Fly Ash bricks of size 23x11x7cm and inside plastering with 1:3 (one of cement and three of P-sand) 12mm thick including channeling, benching etc. and top covered with SFRC (medium duty) cover slab and fixing in position and necessary earth work excavation, refilling the sides of foundation in all soils except hard rock requiring blasting etc. complete in all respects as directed by the departmental officers. (Average Depth of 0.90m)

30

-

-

... More
GST @ 18 %

18

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.