Tamil Nadu Startup And Innovation Mission Tender

Search from a plethora of business opportunities for Tamil Nadu tenders posted on the eProcurement TamilNadu website and other online and offline sources. Here, on BidAssist, you can find the best tender opportunities to boost your enterprise by finding work in Tamil Nadu government tenders, PSUs, Municipal Corporations and more. Read on to learn about the bidder registration process, DSC and more.

Tamil Nadu Startup And Innovation Mission Tender

Civil And Construction
Building Construction
Eprocure
Opening Date27 May 2023
Closing Date16 Jun 2023
Tender Amount₹ 11,26,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Dismantling of existing Brick/ Stone Masonry in cement mortar walls, add for every additional 3m or part there of over the initial height of 3m including stacking of serviceable materials etc., Complete complying with standard specifications and as directed by the "Engineer-in-charge/Architect".

25

-

-

... More
Dismantling of existing PCC and removing the debris etc., Complete complying with standard specifications and as directed by the "Engineer-in-charge/Architect".

25

-

-

... More
Dismantling of existing RCC and removing the debris etc., Complete complying with standard specifications and as directed by the "Engineer-in-charge/Architect".

25

-

-

... More
Plain Cement Concrete, Centering, RCC and Steel works

-

-

-

... More
Providing and laying plain cement concrete 1:4:8 using 20 mm and below size hard broken stone in the above mentioned pits after erecting the vertical posts in position including vibrating, curing etc., Complete complying with standard specifications and as directed by the "Engineer-in-charge/Architect".

15

-

-

... More
Supplying and erecting centering for sides and soffits including supports and strutting up to 3.30 m height with all cross bracing for plane surfaces as detailed below, using mild steel sheets of 90 X 60 cm 10 gauge stiffened with MS angle of 25 X 25 X 3mm for boarding, laid over adjustable span & jacks and supported by 50mm dia pipes for general pipes scaffolding systems @ a spacing of 1.20m c/c and vertical connected at a height of 2.0m c/c including 'C' & 'U' clamps and base receiver cup at bottom for connecting pipes etc and removable systems etc., Rate to include all materials, labour charges, wastages , placing, transportation, lead & lifts, tools & plants, fuels, fixing in position at all levels, heights, masking tape in sheet joints, consumables etc., Complete complying with standard specifications and as directed by the "Engineer-in-charge/Architect".

-

-

-

... More
For Plane surfaces such as RCC floor slab, roof slab, beams, lintels, bed blocks, landing slab, waist slab, portico slab / beams and such other members

25

-

-

... More
For plane surfaces such as rectangular,square columns and chamfered sunshades, top and bottom slab of boxing, kitchen platform, loft and such other structural members

7

-

-

... More
Providing and Laying M 30 Design Mix for all reinforced cement concrete with minimum cement content conform to IS 456-2000 using ordinary Portland cement of grade 53 from approved manufacturer, manufactured sand, 20 mm and down graded size coarse aggregates, necessary approved admixtures as per requirement. works for Raft, Grade beam, Shear wall, RCC walls, Lift walls, Plinth beams, Column, footings, Grade slab, Roof slab & beam, Curved slab, beam, Column drops, Pergola, Staircase waist and landing slab lintel, Sunshades, parapet Cum drops, Steps, canopy, window boxing slab, Loft, fins, facia Planter box, binders, basement, retaining wall, machine foundation, elevation features and other similar structures etc..excluding necessary centering, shuttering and reinforcement which shall be measured and paid separately under relevant items.

-

-

-

... More
Supplying, fabricating and fixing in position of steel Fe-550D grade Reinforcement for all RCC work with Thermo Mechanically Treated Bars (TMT) conforming to IS 1786 of latest version according tRate to include all designing the mix, batching plant, mechanical mixing, transporting and placing at all levels, leads, lifts, tools & plants, fuels, all materials, labour charges, wastages , laying, pumping the concrete to all levels, providing sleeves / openings in RCC slabs, compaction by vibrator, curing etc., Complete complying with standard specifications and as directed by the "Engineer-in-charge/Architect".o drawings and binding the reinforcement with 18 gauge double fold GI binding wire and providing Concrete / PVC cover blocks to maintain the cover as required. Rate to include all bending, tying grills, placing, transportation, lead & lifts, tools & plants, fuels, all materials, labour charges, wastages , laying at all levels, fixing in position, cost of cover blocks etc., Complete complying with standard specifications and as directed by the "Engineer-in-charge/Architect".

3

-

-

... More
Supplying, fabricating and fixing in position of steel Fe-550D grade Reinforcement for all RCC work with Thermo Mechanically Treated Bars (TMT) conforming to IS 1786 of latest version according to drawings and binding the reinforcement with 18 gauge double fold GI binding wire and providing Concrete / PVC cover blocks to maintain the cover as required. Rate to include all bending, tying grills, placing, transportation, lead & lifts, tools & plants, fuels, all materials, labour charges, wastages , laying at all levels, fixing in position, cost of cover blocks etc., Complete complying with standard specifications and as directed by the "Engineer-in-charge/Architect".

2.5

-

-

... More
Masonry Works

-

-

-

... More
Providing and constructing cement concrete solid block masonry work at all levels in cement mortar 1:3 using standard size of 400 x 200 mm of solid cement concrete blocks of thickness as given below, with minimum compressive strength of 5 N / Sq.mm. conforming to IS 2185 or equivalent BS and Fly ash conforming to IS : 3812 (Part III)-1966* may be used for part replacement of fine aggregate up to a limit of 20 percent. including all scaffolding, staging, curing, all lifts etc. complete and as directed. Concrete blocks manufactured under strict quality control conditions using modern rugged block casting and stripping machine with the latest moulding techniques etc. only shall be used. (Rate to include the column and fixing 200 mm long 50 x 4 mm hick MS bend to shape with anchor bolts at every fifth course the rate is inclusive of case of fabrication structural steel with all leads and lift) Note: All mortar to be machine mixed etc., Complete complying with standard specifications and as directed by the "Engineer-in-charge/Architect".

-

-

-

... More
200mm thick wall

15

-

-

... More
150mm thick wall

15

-

-

... More
100mm thick wall

15

-

-

... More
Providing and constructing Autoclaved Aerated Concrete block masonry work in cement mortar 1:3 using standard size of 600 x 200 mm of AAC blocks. Blocks manufactured under strict quality control conditions confirming to IS standards only shall used

-

-

-

... More
a) Fixing the panels at all levels and supported on slab soffit with suitable arrangement including necessary staging, scaffolding arrangement, alignment and verticality (plumb level) of the walls. Rate Shall also include cutting necessary grooves / chases of required size and at required height for concealing electrical, plumbing, conduits / pipes, holdfasts, bolts etc. and making good surfaces after concealing work is complete.

-

-

-

... More
b) Grouting of cores in blocks to complete course for fixing of frames and all joinery works etc. complete, as directed. All materials required to carry out all related works including specialized work required around and above opening to receive the Frame and to ensure that the load of the panels are not transferred on to the frames or shutters of the doors, windows and ventilators so as to avoid bending of door frames/shutters and affecting the opening / closing operation of the door shutter. etc. complete and as directed.

-

-

-

... More
c) Finished work should be sand papered to receive plaster and any unevenness or undulations on the block should be made good by the application putty.

-

-

-

... More
d) If required to do so the test at an approved laboratory to ensure the compression strength of blocks confirming to IS standards.

-

-

-

... More
Rate shall include accessories for supporting the system into the ceiling with cleats & Anchor fasteners, scaffolding, loading and unloading, lead & Lift, Tools & Plants, curing, cleaning, pointing both sides, racking etc., Complete complying with standard specifications and as directed by the "Engineer-in-charge/Architect".

-

-

-

... More
For 200mm thick AAC block wall

90

-

-

... More
For 150mm thick AAC block wall

15

-

-

... More
For 100mm thick AAC block wall

151

-

-

... More
Providing and constructing of brick work in Cement Mortar 1:5 (One Cement and Five M.sand) using best quality of Second Class Ground Moulded Chamber Burnt Bricks 9" x 4 3/8" x 2 3/4" with minimum compressive strength of 35 Kg per Sqcm for foundation and all floors including curing etc., Complete complying with standard specifications and as directed by the "Engineer-in-charge/Architect".

-

-

-

... More
230 mm thick

4

-

-

... More
Providing and constructing of brick partition walls in Cement Mortar 1:3 (One Cement and Three Sand) using best quality Second Class Ground Moulded Chamber Burnt bricks of size 9" x 4 3/8" x 2 3/4" with hoop iron reinforcement if found necessary including curing etc., Complete complying with standard specifications and as directed by the "Engineer-in-charge/Architect".

-

-

-

... More
115 mm thick

27

-

-

... More
Internal Plastering works

-

-

-

... More
Plastering of 12mm thick plaster on internal surfaces of RCC/brick/block walls in cement mortar 1:5 (1 of Cement : 5 of P.Sand). Rate shall include for scaffolding, drip band / grooves of any size and shape, curing, surface preparation before the application of plaster, providing galvanized mesh to a width of 150mm at the junctions of masonry and concrete works, wherever conduits and pipes are concealed and packed in the wall; and also providing and fixing of galvanised corner beeds for all corners/ edges of columns and walls including tying in position by using suitable nails / clamps / screws and as directed etc. complete at all levels. Rate to include screening and washing of sand and all mortar for plastering to be machine mixed etc., Complete complying with standard specifications and as directed by the "Engineer-in-charge/Architect".

92

-

-

... More
Plastering of 12 mm thick water proof plaster in Toilet internal walls and over head tank with CM 1:3 (1 of cement : 3 of P.Sand) with water proofing compound of CICO No:1 or equivalent as per manufacturer’s specification and roughening the surface in green condition with wire brush and clearing of loose particles with sponge brush (washed sand finish) etc., Complete complying with standard specifications and as directed by the "Engineer-in-charge/Architect".

144

-

-

... More
Plastering of Internal ceiling with cement mortar 1:3, 10 mm thick with a neat floating coat of cement to the finish according to specifications. Rate shall include necessary staging, curing, scaffolding, proper hacking, cleaning, at all levels and elevations etc., Complete complying with standard specifications and as directed by the "Engineer-in-charge/Architect".

25

-

-

... More
Supply and application of 10mm thick Perlite based Gypsum plaster on internal RCC wall, beam, block wall and Ceilings surfaces with Bulk density of 650-710 Kg/m3 and finesses of 95% passing through 150 micron. Rate shall be include for Surface Preparation, filling cracks in the background if any, surface cleaning/curing (if required), finishing of Electrical Switch Boxes, light points, DB’s etc. and necessary staging, scaffolding, GI edge beading, GI plaster mesh at all levels and elevations and also include cost of material, labour, unloading and shifting of material, water etc., Complete complying with standard specifications and as directed by the "Engineer-in-charge/Architect".

133

-

-

... More
Internal Painting works

-

-

-

... More
Providing and finishing the Existing Ceiling surface with necessary grinding, touchup plasteriing, POP works wherever required area to finish etc., Complete complying with standard specifications and as directed by the "Engineer-in-charge/Architect".

686

-

-

... More
Preparing surface, Supply and application of first class POP punning plaster to a thickness of 6-10 mm over exposed plastered wall surface including scaffolding etc. complete. Rate to include for making the wall with plumb line and get smooth surface to receive the paint. Working at all levels and heights etc., Complete complying with standard specifications and as directed by the "Engineer-in-charge/Architect".

5

-

-

... More
Providing and applying two coats of Acrylic emulsion paint with low of approved colour over a coat of water based primer including preparation of surface by thorough cleaning and applying two coats of premixed putty as per manufacturer’s specification fully to give an even shade before painting and curing etc., Complete complying with standard specifications and as directed by the "Engineer-in-charge/Architect".

-

-

-

... More
Walls and Partitions & Gypsum False Ceiling

3973

-

-

... More
Ceilings without putty

25

-

-

... More
Providing and applying Oil based primer finish to walls as the base for Vinyl Wall Paper/ Graphics. Existing wall /gypsum / MDF board surfaces to be prepare by scraping away any loose particles, dust, etc by washing and scrubbing and 2 coats of oil based primer applied. The wall surfaces are then smoothened using chalk putty as directed. Surfaces are then sandpapered to achieve a smooth finish and made ready to receive wallpaper / graphics as directed. Rate should be inclusive of applying Protection/Masking for fixtures & joineries., nearby. Working at all levels and heights etc., Complete complying with standard specifications and as directed by the "Engineer-in-charge/Architect".

5

-

-

... More
Providing and applying of Texture paint of approved make to walls of approved colour over a coat of primer as per manufacture specification. The rate shall be including preparation of surface by thorough cleaning and as per manufacturer’s specification fully to give an even shade as directed etc., Complete complying with standard specifications and as directed by the "Engineer-in-charge/Architect".

80

-

-

... More
Supply and Application of real concrete finish of 1mm , Eco cement achieved by mixing cement and polymer on the desired base for internal walls, over a coat of water base primer and putty done surface. The final coat is achieved with PU sealer. The concrete is made breathable by using the right polymer proportion which makes the material non cracking. The rate shall include of material and application on the prepared surface without undulations by the painter etc., Complete complying with standard specifications and as directed by the "Engineer-in-charge/Architect".

52

-

-

... More
Providing and applying of two coats of Duco paint of approved colour and make over a coat primer including preparation of surface by thorough cleaning as per manufacturer’s specification fully to give an even shade and necessary metal paste putty as required. Rate shall be inclusive of wastage, scaffolding, spray equipment etc. measurement as per SP 1200 guidance etc., Complete complying with standard specifications and as directed by the "Engineer-in-charge/Architect".

5

-

-

... More
Painting two coats with melamine polish of best approved quality complying with standard specification and approved quality etc., Complete complying with standard specifications and as directed by the "Engineer-in-charge/Architect".

5

-

-

... More
Water Proofing Works

-

-

-

... More
Supplying and filling the toilet area by BRICK-BATCOBA by adding CICO NO:1 or approved equivalent admixture including applying two coats not less than 2 mm thick of TAPECRETE- Acrylic Polymer Based Waterproof Coating, over the final coat of cement plaster 12 mm thick with cement sand mortar 1:3 mixed with water proofing compound like CICO No.1 at the rate specified in the manufacturer's specification after entire completion of laying pipes, sanitary fittings etc. Rate including all materials, labour charges, wastages with necessary lead and lifts, working at all levels, protecting the laid pipes and sanitary fittings, finishing the surface smooth to receive the top coat of water proofing application etc., Complete complying with standard specifications and as directed by the "Engineer-in-charge/Architect".

3

-

-

... More
Supply and laying water proofing treatment of Toilet, covering the following order and consisting of following operations. The Toilet slab shall be thoroughly cleaned to remove debris and dust . Making V Groove over the construction Joints & filling V Groove with CICO Quick setting Material admixed with Cement & Application of 2 coats of TAPECRETE - Acrylic Polymer Cementitious coating over well prepared surface , followed by a layer of plastering with cement mortar 1:3, 20mm thick admixed with CICO NO:1 @ 2% by weight of cement. (Treatment shall be given up to 1.5 M height around shower area and 1M height at all other vertical area above finished floor lvl) etc., Complete complying with standard specifications and as directed by the "Engineer-in-charge/Architect".

41

-

-

... More
Flooring,Skirting and Dadoing Works

-

-

-

... More
Providing and laying in panels not more than 20 sqm. in plan granolithic flooring with cement concrete 1:1.5:3 by using coarse graded aggregate of 6 to 12 mm size laid monolithic with floor concrete and finished smooth with power trowel including preparation of concrete surface and form work. The screed shall be laid for effective separation of panels not exceeding 20 sqm in plan etc and Unevenness in floor finish shall not exceed +2mm in one square metre area. Including sprinkling of Nitoflor Hardtop Standard evenly a shake on a ready mixed non-metallic monolithic floor hardening compound with very hard granulates of mineral origin over concrete floor when the concrete in green and touch dry condition at the rate of 5 Kgs/Sqm. Nitoflor Hardtop Standard shall possess a compressive strength of 50N/mm² as per IS: 516-1959, Moh's hardness not less than 8, as per specification and instructions of the manufacturer. Rate to include lead , lift at all levels, pumping, placing, necessary formwork, curing etc., Complete complying with standard specifications and as directed by the "Engineer-in-charge/Architect".

-

-

-

... More
Average 70 mm thick.

2028

-

-

... More
Average 50 mm thick.

22

-

-

... More
Supply and Laying flooring with best quality of Granite slab leather finish 18 to 20mm thick (Steel Grey, Sira Grey, Ruby Red, SK Blue, Raw silk, Antique Brown) of size not less than 1200 x 600 mm machine cut with approved pattern in a single colour/multiple colour and set in C.M 1:4 (1 of cement : 4 of sand) 20 mm thick topped with white cement slurry (for surface contact of the bottom of the granite slab) as per approved pattern, including finishing the joints with matching shade, cement slurry, cutting, edge chamfering and polishing rough, medium, nice and tin-oxide polish. Rate shall include wastages, preparation of base surface, cleaning, acid wash over the finished surface, protection with Gypsum / Pop layer over plastic sheet and removing the same before handing over, work at all levels etc., Complete complying with standard specifications and as directed by the "Engineer-in-charge/Architect".

5

-

-

... More
Extra for pre finished nosing to treads of steps, counter, ledge wall top of Granite stone etc., Complete complying with standard specifications and as directed by the "Engineer-in-charge/Architect".

252

-

-

... More
Providing and fixing of flooring with quality approved make of Glazed Vitrified Tiles (GVT) - (seamless joint) confirming to IS 13006/EN 176 Group B1a with technical specification as Mohs scratch hardness minimum 7, Water Absorption of less than 0.5%, Modulus of Rupture greater than 35 N/mm2, Deep Abrasion resistant maximum 175 mm 3 Surface flatness, Straightness of sides ± 0.25%, thickness ± 5% of size of approved colour and size & thick as specified below, set in 20mm thick C.M.1:4(1 cement and 4 manufactured sand ) and pointing with white cement to matching colour shade as per Manufacturer's Specification and as directed. Rate shall include wastages, for preparation of base surface, cleaning, acid wash, and finished surface, protection with Gypsum / Pop layer over Plastic sheet and removing the same before handing over, work at all levels and as directed. Rate shall be inclusive of forming pattern etc., Complete complying with standard specifications and as directed by the "Engineer-in-charge/Architect". Size of tiles shall be - 1200 x 600 x 9mm

103

-

-

... More
Providing flooring with best quality approved make Anti Skid Ceramic tiles ranges, from approved make to the pattern as shown in the Architectural Drawing. The size of tile shall be as per the samples approved, set in CM 1:4, 20mm thick and pointing the joints with white cement to matching colour shade as per Manufacturer's Specification and as directed. Rate shall include for preparation of base surface, and finishing the surface, cleaning the surface, and protecting with Gypsum / POP layer over Plastic sheet and removing the same before handing over, work at all levels etc., Complete complying with standard specifications and as directed by the "Engineer-in-charge/Architect". Size of tiles shall be 300mm x 300mm x 6 to 7mm.

21

-

-

... More
Supply and laying with best quality the following materials of Machine Polished granite slab for counter / wash basin counter top of 18 mm thick (Jet Black) including cutting for wash basin and edge polishing to be set in CM 1:4 (1 of cement : 4 of manufactured sand) 20 mm thick including finishing the joints with white cement slurry, cutting, edge chamfering to approved shape and polishing rough, medium, nice and tin-oxide polish and providing the hole in the granite for fixing the pillar cock tap etc., Complete complying with standard specifications and as directed by the "Engineer-in-charge/Architect".

6

-

-

... More
Providing Sill and Ledge coping with granite of approved shade and to a thickness not less than 18mm, set in cement mortar 1:4 and joint finish with approved grout of matching shade, as per Manufacturer's Specification. Rate shall include for cutting, bull nosing, chamfering, polishing, preparation of base surface, joint finish with approved grout etc., Complete complying with standard specifications and as directed by the "Engineer-in-charge/Architect".

132

-

-

... More
Supplying and laying for flooring with White Marble slab (Adanga) not less than 18mm thick set in appropriate Laticrete adhesive as per approved pattern/design drawing using irrespective of size and shape, including finishing the joints with Laticrete make to matching colour shade. Rate shall include for preparation of base surface, cutting, edge chamfering and polishing rough, medium, nice and acid wash and tin-oxide polish as per manufacturer's Specification and as directed. Rate including all materials, labour charges, working at all levels, loading, unloading, preparation of base surface & finished the surface, protection with Gypsum / Pop layer over Plastic sheet and removing the same before handing over,work at all levels etc., Complete complying with standard specifications and as directed by the "Engineer-in-charge/Architect"

74

-

-

... More
Supply and Laying Glazed Vitrified Tiles (GVT) skirting - 100 mm high of same approved flooring tile set in C.M 1:3 (1 of Cement : 3 of manufactured sand) 12 mm thick and pointing the joints with white cement compound and matching corner tile beading etc., Complete complying with standard specifications and as directed by the "Engineer-in-charge/Architect".

48

-

-

... More
Providing and fixing of Modular Skirting over partition, columns and walls with all accessories. The screws anchored should be recessed and covered with gaskets. Rate should include Covers at corners & ends, screws, wall chipping, plastering, punning., complete at all levels and heights etc., Complete complying with standard specifications and as directed by the "Engineer-in-charge/Architect".

-

-

-

... More
Anodized Aluminum skirting with 50mm height

5

-

-

... More
Anodized Aluminum skirting with 75mm height

1158

-

-

... More
Anodized Aluminum skirting with 100mm height

5

-

-

... More
Supply and Fixing Dadoing with best quality polished vitrified tile of approved make set in C.M 1:3 (1 of Cement : 3 of manufactured sand) 12 mm thick and pointing the joints with white cement compound and matching corner tile beading. Rate including all materials, labour charges, wastages, necessary lead and lifts, working at all levels, transportation charges, loading, unloading, chasing of wall for flushing the tile inline with wall surface, preparation of surface, necessary hacking in RCC surface, cutting of tiles to required shape, edging, tools and plants, fuel, curing, cleaning, acid wash over finished surface, protection with Gypsum / Pop layer over Plastic sheet and removing the same before handing over etc., Complete complying with standard specifications and as directed by the "Engineer-in-charge/Architect" (Toilet - size of Tiles shall be - 300 x 600 x 9mm

5

-

-

... More
Providing Dadoing with best quality Ceramic tile of approved make and size set in cement mortar 1:3 (1 of Cement : 3 of manufactured sand), pointing the joints with white cement compound and matching corner tile beading. Rate including all materials, labour charges, wastages, necessary lead and lifts, working at all levels, transportation charges, loading, unloading, chasing of wall for flushing the tile inline with wall surface, preparation of surface, necessary hacking in RCC surface, cutting of tiles to required shape, edging, tools and plants, fuel, curing, cleaning, acid wash over finished surface, protection with Gypsum/Pop layer over Plastic sheet and removing the same before handing over etc., Complete complying with standard specifications and as directed by the "Engineer-in-charge/Architect" (Kitchen & dish wash-Size of Tiles shall be-450 x 300 / 600 x 300mm x 6 to 7mm).

97

-

-

... More
Supplying and fixing jet black 20 mm thick granite stone 1200 x 600 mm to shape finished with polished on both sides, slab table rubbed, edges rounded, cutting, edge chamfering and polishing etc., for urinal partition and any other partitions. The urinal partitions should be anchored to the wall with two / four numbers of 316 grade SS brackets and with anchor fasteners with SS caps. Quoted rate should be inclusive of all the mentioned works., Working at all levels and heights etc., Complete complying with standard specifications and as directed by the "Engineer-in-charge/Architect"

3

-

-

... More
Supplying and installation of Modular Carpets made with 100% nylon 6 or 6.6 manufactured using digital injection or 100% solution dyeing process. The carpet should have protective treatment for soils, stains and anti microbial additives. The backing shall be with either PVC free PU underscore cushion or recyclable / recycled PET hard backing as per manufacturer's specification and as required by the Engineer-in-charge/Architects/Clients/PMC. Carpet to meet ARR - Severe Rating as per CRI TM 101 and CRI LEED certified. The installation of carpet should be with green adhesive of approved make, all complete as per manufacturer's specifications. Working at all levels and heights etc. The laying pattern should be as per Architect's inputs and approval etc., Complete complying with standard specifications and as directed by the "Engineer-in-charge/Architect". The quoted rate shall be inclusive preparing the surface and laying of carpet tiles optimized for glue-free installation with tactile connectors or with adhesives virtually VOC less than 50 grams/ litre for fixing over existing flooring as per Manufacturer's specification. Method of Measurement: Supply and Installation: Actual laid area will be measured and paid as per the site conditions under the respective items. Attic Stock: Number of factory packed cartons handed over to Clients / PMC which will be measured in Sqm, under the respective items. Warranties: Carpets should have minimum 15 Years warranty against Delamination of backing, Stain resist, antistatic, face fiber wear, dimensional stability, flaAlbansbility, tufted bind, colourfastness to light and atmospheric contaminants etc., Vendor Should submit warranty certificate satisfying the above criteria.

-

-

-

... More
Shape and Size - Square / Plank Construction - Tufted Surface Texture - Textured Patterned Loop / Texture Loop Multilevel Pattern cut /loop pile / Random Tipshear Tufted Face Weight: Not less than 18.0 oz./yd2 Stitches per inch: Not less than 9 Gauge: 1/12" Finished pile thickness: Not less than 0.1" Average Density: In the range of 6000 oz./yd3

1801

-

-

... More
Supplying of 2% Attic stock of carpet. Attic stock has to be handed over to Clients in factory packed condition. Attic stocks to be rounded off to the nearest Square meters that will be accommodated in factory packed cartons etc., Complete complying with standard specifications and as directed by the "Engineer-in-charge/Architect".

38

-

-

... More
Supplying and installation of 6.5mm thick Sports Vinyl flooring of approved make and shade over the existing self leveled floor. The fixing to be done with VOC free water based adhesives and the joints to be neatly welded as per manufacturers methodology. The rate shall include 50mm X50mm PVC cove fillet, wall base transition strip to a height of 100mm, all cuttings, wastages, cutting cost of all materials adhesives, including welding of joints, cleaning the surface, making dust free, including all the materials and labour mentioned above for complete finished work at all levels and heights etc., Complete complying with standard specifications and as directed by the "Engineer-in-charge/Architect".

-

-

-

... More
The sports vinyl flooring must comply with the following standards and specifications. Classification : 34, (EN 685 commercial ) Min. thickness : 5 mm (EN 428) Ware layer : 0.7 mm thick (EN 429) Total weight : 2800 g/m2 (EN 430) Surface Treatment : PUR Reinforced Abrasion Group : Group P: ≤ 27% (EN 14808) Dimensional stability : ≤ 0.10% (EN 434) Reaction to fire : Cfl-s1 (EN 13501-1 ) Friction : 88 (EN 13036-4)

3

-

-

... More
Supplying and installation of 2mm thick Luxury Vinyl flooring of approved make and shade over the existing self leveled floor. The fixing to be done with VOC free water based adhesives and to be laid as per manufacturers methodology. The rate shall include all cuttings, wastages, cost of all materials adhesives, cleaning the surface, making dust free, including all the materials and labour mentioned above for complete finished work. Only laid area will be measured for payment etc., Complete complying with standard specifications and as directed by the "Engineer-in-charge/Architect".

3

-

-

... More
Supplying and installation of 2.0mm thick Anti static Vinyl flooring of approved make and shade over the existing self leveled floor. The fixing to be done with VOC free water based adhesives and to be neatly welded as per manufacturers methodology. The rate shall include all cuttings, wastages, copper strips, cost of all materials adhesives, including welding of joints, cleaning the surface, making dust free, including all the materials and labour mentioned above for complete finished work. Only laid area will be measured for payment etc., Complete complying with standard specifications and as directed by the "Engineer-in-charge/Architect".

37

-

-

... More
Providing, laying Self Leveling Compound for Vinyl Flooring to average 3mm to 4mm thickness using self leveling compound of approved make below the Vinyl flooring for achieving the smooth, hard and absolutely leveled surface is made available to avoid undulations in the top flooring. The Self leveling shall be laid in accordance with the manufacture guidelines using the tools and accessories recommended, complete as per the drawing at all levels and heights etc., Complete complying with standard specifications and as directed by the "Engineer-in-charge/Architect". Location: Base for Sports flooring, Luxury vinyl and Anti static vinyl flooring

37

-

-

... More
Providing and laying self leveling three component pigmented Epoxy joint less floor topping "Shalideck - SL " - 750 microns or approved equivalent make, over granolithic flooring as per manufacturer's specification. Rate shall includes 100 mm height of wall skirting and including preparation of surface, application, wastage, equipment, tools and plants, work at all levels and heights etc., Complete complying with standard specifications and as directed by the "Engineer-in-charge/Architect".

5

-

-

... More
Supplying and laying of Broad Loom Carpet (42 Oz) are as follows: Broadloom Carpet -Tufted cut pile, min. Gauge 1/10 per inch, Pile material to be 100% Continuos Filament Nylon 6,6 Digital Injection Dyeing/Millitron dyed, Backing- Woven textile as per eTL, dimensions 400 cm as per ISO 3018, total thickness 10 mm, surface pile thickness 7.5 mm, Min 118 tufts per sq. inch (1800 tufts/100 cm2), carpet weight 3200 g/m2, Pile yarn weight 1400 g/m2, surface Pile density- min 5600 oz/ yd3, Soil protection technology inbuilt for Soil Repel, Soil Resist & Soil Release, Antimicrobial Properties technology for lifetime Anti Microbial Treatment to control/ prevent Mold, Moldew & Odour, Texture Appearance Rating: As Per Hexapod Drum Test (ASTM-D5252) Min. for Commercial Heavy usage & Constant Castor Chair usage as per EN 1307, Anti Static Property as per Static Electricity (AATCC-134) 20% R.H.,70° F should be ≤ 3.5 KV, Permanent Conductive Fiber. Manufacturers should certify 10 years Comprehensive Warranty for replacament incase of any manufacturing or latent defect. Acou.insu. from impact noise 29db, acoustical absorption 0.30 aW, Suitable for heated floors as per ISO 8302 / equivalent Indian standard or International standard, Colour fastness to light ISO 105- B02 / equivalent Indian standard or International standard ≥6, Colour fastness to rubbing wet EN ISO 105-X12 / equivalent Indian standard or International standard ≥ 5 Colour fastness to rubbing dry EN ISO 105-X12 / equivalent Indian standard or International standard and minimum “4” rating or higher for color loss using the AATCC Gray Scale (5= no change; 1= severe bleach stain). Fire Ratings: Smoke Density (NFPA-258-T or ASTM-E-662) should be Less Than 450 Flaming & Non-Flaming, Radiant Panel Test. As per FlaAlbansbility (Radiant Panel ASTM-E-648) should be Class l, Greater Than .45 Watts/cm², certified CE Labelling as per EN 14041; Certified Slip resistance as per EN 13893, Indoor climate Air Quality Green Label Plus Approved for GLP2860, Category 1Y, Environment Cradle To Cradle Certified as per silver certified, . Additional Certification: NSF 140 & Declare Smart ® Certified for Interior Finishes etc., Complete complying with standard specifications and as directed by the "Engineer-in-charge/Architect".

30

-

-

... More
Supplying and fixing of Welspun flooring in Greens look as real as natural grass. Ideal for sports arenas, commercial applications, residential terraces and gardens, it is easy on maintenance too. It's easy to install and drains out rain water easily. The installation process for Greens can be broadly classified under 3 different heads, namely - Preparing the area, Installing the base & Installing the lawn etc., Complete complying with standard specifications and as directed by the "Engineer-in-charge/Architect".

-

-

-

... More
Artificial Grass type thickness is 25mm

8

-

-

... More
Artificial Grass type thickness is 35mm

2

-

-

... More
Artificial Grass type thickness is 45mm

2

-

-

... More
Providing and fixing of Access floor systems of approved make confirming to PSA MOB - PF2 PS/SPU, BS 476 - Part 6, ASTM E84 1998 and ASTM E136. System: Access floor system to be installed shall provide a maximum finished floor height as mentioned below. The system shall provide suitable pedestal and under-structure designed to withstand various static loads and rolling loads. The entire Access floor system shall provide adequate fire resistance, acoustic barrier and air leakage resistance. Panels : Access Floor panel of size 600x600 mm shall be all steel welded construction, with an enclosed bottom pan of 64 hemispherical cones and top plain sheet which are fuse welded at minimum 81 locations to form a panel of an overall depth of minimum 29 mm. The inner empty core of the panel is injected with a light weight fire retardant, non combustible cementitious compound at high pressure to fill in all the crevices of the panel and ensures support of not less than 85% of the top surface area of the panel. The panel after cleaning, degreasing, phosphate by 7 tank process is coated with minimum 40 micron epoxy coat and is heated to achieve maximum adhesion and surface resistance. The Panels shall be UL listed / FM approved. The panel is either bare finish or laminated with 1.5 mm thick fire retardant floor grade antistatic laminate / pvc on a semi -automated lamination line to ensure maximum bonding to the steel surface. The edges of the laminated/PVC are protected with black PVC edge trim 5mm wide on all sides. This edge trim is mechanically locked and sealed in place to avoid detachment. Pedestals : Pedestal installed to support the panel shall be suitable to achieve a finished floor height as mentioned below. Pedestal design shall confirm speedy assembly and removal for relocation and maintenance. Pedestal base to be permanently secured to position on the sub floor. Pedestal assembly shall provide for easy adjustment of levelling and accurately align panels to ensure lateral restrain. Pedestals shall support an axial load of 2000 Kgs, without permanent deflection and an ultimate load of 3500 Kgs. Pedestal head shall be designed to avoid any rattle or squeaks. Pedestal Assembly : Consisting of 100 x 100 x 2mm thick galvanized epoxy polyester coated MS Base plate die-pressed orbitally riveted to a 21mm O.D. 2.5mm thick epoxy coated MS pipe to engage the pedestal head assembly. The pedestal head assembly consists of an embossed steel plate having 4 holes with ¼ the tapping for fastening and locating of tile ; orbitally riveted to a corresponding threaded stud 16mmdia. (O.D), length 100mm which is designed to engage the pedestal base assembly. The assembly shall provide a range of height adjustment upto 25mm, with the help of check nuts. Under structure : Under structure system consists of stringers of size 570 x 32x 20 x 1.5mm to form a grid of 600 x 600mm. These stringers are locked into the pedestal head and run both ways. The US system shall provide adequate solid, rigid and quiet support for access floor panels. The US system shall provide a minimum clear, uninterrupted height of 350 mm minimum, between the bottom of the floor and bottom of the access floor for electrical conduiting and wiring. Stringers : Stringer system is all steel construction, rectangular channels 30 x 20 x 1.6mm thick with pre-punched counter sunk holes at both ends for securing the stringers onto the pedestal head ensuring maximum lateral stability in all directions. The grid formed by the pedestal and stringer assembly shall receive the floor panel. Panel Loading: The panel dimensions and performance must confirm with PSA MOB - PF2 PS/SPU standards for a heavy duty panel and must comply with the, Concentrated Point Load : 360 kgs on a 25 x 25 mm square on the center of the panel with a maximum permissible deflecting of not more than 2.5mm & Uniformly Distributed Load (UDL): 1650 kg/M2 with a maximum permissible deflection of not more than 2.0mm. Fire Rating : The Panels shall confirm to Class O & Class 1 Fire Ratings tested as per BS 476 Part 6 & 7. Rate shall include to produce a test certificate for the above load of approved laboratory, preparation of surface, cutting for supply / return Air Grills and for Grommet of required size, wastages, lead & lift, grouting the system with anchor fastener, removing all debris from the premises etc. and for providing and applying of 500 micron Epoxy painting as a sub floor insulation to the entire area of existing floor(Below false flooring) as per manufacturer's specification etc., Complete complying with standard specifications and as directed by the "Engineer-in-charge/Architect".

-

-

-

... More
To a height of 300mm with Antistatic HPL finish

25

-

-

... More
Joinery Works

-

-

-

... More
Providing and fixing of factory finished solid Beech Wooden door Frame as per drawing detail. All the wooden surfaces to be sanded to required level, treated with wood putty and finished with PU polish to the satisfaction of Architects / Client. The wooden frame to be treated and should be resistant to borer, termite and fungus. The rate shall be inclusive of making necessary design as per drawing, in the frame and necessary Hilti fastener and hardware etc,.complete., Working at all levels and heights etc., Complete complying with standard specifications and as directed by the "Engineer-in-charge/Architect". Finishes shall made at Factory only installation at site.

-

-

-

... More
Finished with PU polish

3

-

-

... More
Finished with a coat of wood primer and two coats of wood enamel paint

0.5

-

-

... More
Supplying and fixing Door Frames using Teak Wood of quality and size as per the specification/drawings attached including planning, providing plaster groove, form pockets in Blockwork / fixing anchor fasteners from Hilty or Fischer in RCC, fixing necessary Z clamps made out of 40x6mm MS Flat of 400mm long in frame, fixing frame in position, grouting the pockets using CC 1:1:2, applying two coats solignum paint on surface frame butting on masonry, applying one coat wood primer etc., Complete complying with standard specifications and as directed by the "Engineer-in-charge/Architect"

5

-

-

... More
Supply and Installation of 35mm thick Flush door shutters with or without Vision panel, made of solid core block board type bonded with synthetic resin thermo pressed with 1.5 / 2mm thick PVC edge beading of approved shade. Synthetic resin to comply with IS 848 -2006. The construction procedure of the shutter should be as per IS:2202 - Part1 and 2 and should be fully organic preservative treated as per IS 401. The shutter shall be shop prepared for taking mortise lock or latches suitable with block of wood may be provided for fixing the hardware. The size of block, shall perfectly correspond to the maximum size of lock, covered in IS:2209. All the four edges of the door shutter shall be square. The shutter shall be free from twist or warp in its plane and of required size etc.; complete as directed. The vision panel to be with toughened glass and wooden beadings, all around finished with approved colour paint. Both sides of the door shall be finished with either 4mm thick Veneer or 1.5 mm thick laminate of approved color / pattern. Rate to include installation of door, laminate and veneer with PU polish, necessary accessories for fixing for complete installation., Working at all levels and heights etc., Complete complying with standard specifications and as directed by the "Engineer-in-charge/Architect"

-

-

-

... More
laminate

54

-

-

... More
Veneer finished with PU Polish

2

-

-

... More
Flooring,Skirting and Dadoing Works

-

-

-

... More
Supply & Fixing of Aluminium Glazed Door (Single Leaf) with Glass infill of 10mm thick toughened glass with -100 frames Stiles all around the door. Aluminium Stile to be formed out of 100x45mm of Door Profile frame with clips & seals. For doors part of single/double glazed partiton DP100-SG/DG Door rebate profile to be used. In case of Glass overall panel OHPDP100-SD/DG Over Panel Door profile to be used.The profiles shall be suitable for Glass thickness of 10/12/13.52mm.The Profile shall be matt natural anodized, the Profile Manufacturer to supply all the necessary clips, seals and fixing accessories for the system.All Profiles to be with 2 mm Gauge thickness Excluding 20 Micron of Anodizing etc., Complete complying with standard specifications and as directed by the "Engineer-in-charge/Architect". NOTE: Hardware will be measured seperately and paid under relevant BOQ items.

-

-

-

... More
Single Door - 900mm x 2400mm

27

-

-

... More
Single Door - 1000mm x 2400mm

7

-

-

... More
Single Door - 1200mm x 2400mm

1

-

-

... More
Supply and Installation of minimum Two hours fire rated Hollow metal doors from ISO 9001-2000 certified approved Manufacturer. Fire door should be manufactured and tested in accordance with IS 3614 Part 2, BS 476 Part 20 & 22 for stability and integrity and pressed galvanized steel confirming to IS 277. Fire door shall be tested and certified by a third party evaluation program from approved international agency like CERTIFIRE or CBRI / ARAI and labeled for maximum rating of 2hrs. Labeled doors with certification shall be with vision glass as a part of complete assembly. Manufacturer test certificate shall cover doors both single and double leaf and all doors supplied shall be within the tested specimen, deviation in specification and sheet thickness other than what is mentioned in the test certificates are not allowed. Proper label confirming the type of door and the hourly rating is mandatory. Door frame shall be single / double rebate profile with minimum size of 100 x 55mm made out of minimum 1.60mm (16gauge) thick galvanized steel sheet. Frames shall be mitered and field assembled with self tabs. Frames to have either inbuilt grooved sealing system with fire rated EPDM gasket as standard or shall be without inbuilt groove and sealing to be done as listed in hardware schedule. All provision should be mortised, drilled and tapped for receiving appropriate hardware. Additional reinforcement pads to be provided for hinge jamb, strike jamb and mortar guards. Frames should be provided with minimum 3mm back plate bracket, minimum 6 numbers of anchor fasteners for single leaf and minimum 8 nos anchor fasteners for double leaf doors of minimum 8mm dia, 80mm long for installation on a finished plastered masonry wall opening. Once frame installed should be filled with Fire resistant Polyurethane foam as approved by Client / PMC. After filling the frame, the holes in the frame should be sealed with insert plug as per manufacturer's specification. Door leaf shall be minimum 46mm thick fully flush double skin uninsulated door with minimum 5mm thick fire rated vision lite. Door leaf shall be manufactured from minimum 1.2mm (18guage) thick galvanized steel sheet. The internal construction of the door should be provided with rigid reinforcement pads for receiving appropriate hardware. The infill material shall be resin bonded honeycomb core. All doors shall be factory prepped for receiving appropriate hardware and should be provided with necessary reinforcement for receiving hinges, locks, and door closers. The edges should be interlocked with a bending radius of minimum 1.4mm. For pair of doors astragals has to be provided on the meeting stile for both active and inactive leaf. All doors and frames shall be finished with polyurethane aliphatic grade powder coating minimum 50 microns of approved colour. The door leaf and frame shall have passed minimum 500 hours of salt spray test. Shop drawings with all the fabrication and hardware details to be submitted for Architects approval, before fabrication. Quoted rate to include all the works mentioned above for complete installation of doors. Working at all levels and heights and as directed by Engineer- in- Charge. Necessary Test certificates to be submitted and Quoted rate to include for testing the samples of approved size with hardware, specific to this project. For all access control fire doors with Electric locks, necessary provision to be made for routing of cables. Vendor to get inputs for location of doors from client before procurement etc., Complete complying with standard specifications and as directed by the "Engineer-in-charge/Architect". The door sizes shall be as follows

-

-

-

... More
Single Door - 900mm x 2400mm

3

-

-

... More
Single Door - 1000mm x 2400mm

1

-

-

... More
Double Door - 1500mm x 2400mm

1

-

-

... More
Double Door - 1800mm x 2400mm

1

-

-

... More
Specification same as above, but for Shaft doors with single rebate and Frames all around Including allen key set.

-

-

-

... More
Single Door - 600mm x 1500mm

1

-

-

... More
Single Door - 750mm x 1500mm

1

-

-

... More
Supplying and installation of hardwares for the fire door, Flush Doors, glass doors etc, with necessary accessories. All the Hardware should be Fire rated , CE marked and Certifire approved for Fire rated doors of Dorma or equivalent makes. The hardware details are listed below All the hardware for BS standards doors must comply with the following European standards etc., Complete complying with standard specifications and as directed by the "Engineer-in-charge/Architect". Door Closer - As per EN 1154 - 500000 cycles tested Locks - As per EN 12209 - 200000 cycles tested Hinges- As per EN 1935 - 200000 cycles tested Lever Handle - Confirms to EN 179 and EN 1906 - 200000 cycles tested Panic Bar - Confirms to EN 179 and EN 1125 - 200000 cycles tested PU Foam - tested according to EN1366-4 Door Gasketing seals to confirm BS EN 1634-3

-

-

-

... More
BB 4330 BB Hinges 4"x3"x3mm

96

-

-

... More
BB 3090F BB Hinges 4"x3"x3mm

38

-

-

... More
Flush Hinges 5"x3"x3mm

140

-

-

... More
TS 90 Door Closer

24

-

-

... More
TS 91 Door Closer

42

-

-

... More
TS 92 Door Closer

1

-

-

... More
Pull Handle 22 x 300mm D Type

7

-

-

... More
288A Dead Lock Package

5

-

-

... More
PHA 2000 Single Point Locking Panic Bar

1

-

-

... More
External Trim with Half Cylinder

1

-

-

... More
Offset Pull Handle 25x450mm

34

-

-

... More
917 Narrow Stile Lock Package

34

-

-

... More
Pure 8100 Lever Handle

24

-

-

... More
271 Mortise Lock

24

-

-

... More
60mm - EPC one side key other side thumbturn

24

-

-

... More
Mortice Shaft Dead Bolt 57 mm backset

2

-

-

... More
Flush Pull

2

-

-

... More
Manual Flush Bolt - 300mm

2

-

-

... More
Manual Flush Bolt - 600mm

2

-

-

... More
Raven Door Seal - Single Leaf

2

-

-

... More
Raven Door Seal - Double Seal

2

-

-

... More
Drop Seal - 920mm

1

-

-

... More
Drop Seal - 1070mm

1

-

-

... More
Drop Seal - 1220mm

1

-

-

... More
Partitions and Panelling Works

-

-

-

... More
Providing and fixing of Aluminium base frames as shown in the Architectural Drawing for full height solid drywall partitions, suspended partitions and cladding with Aluminium extruded box sections of size 50 x 25mm x 1.5mm thick in both horizontal and vertical direction at 600 mm c/c spacing. The framework to have 25 x 25x 1.5mm GI 'L' angle cleats fixed to Aluminium box section at the top and bottom. All the vertical frames shall be continuous and should be anchored to the floor and soffit of slab. Alternate vertical frames should be anchored to the soffit of RCC slab with additional 'Y' supports. The cost to include necessary hardware as required to complete the works as per the manufacturer's specification. Actual laid area will be measured and paid. Working at all levels and heights etc., Complete complying with standard specifications and as directed by the "Engineer-in-charge/Architect". Note: 1.Actual laid area will be measured and paid. Doors, glass panels and Windows provided in the partition the area will be deducted. 2. No deductions for service penetrations. 3. Rate to include additional supports for large service openings. 4. Applying acoustic sealant between the floor and floor sections / Ceiling and ceiling sections 5. Necessary Aluminium box section backing to be provided for handing the soft board / white board panels. 6. Vendor to quote only for frames along with accessories as described above. First and second skins will be given under relavent item. 7. Rate to include for curve/ circular and any other shape etc.,

-

-

-

... More
Partitions and Suspended partitions

107

-

-

... More
Column and Wall paneling

157

-

-

... More
Supply and Installation of Dry wall partition as shown in the Architectural Drawing to the thickness and height as mentioned below. But generally the partition shall be with GI stud, flooring and ceiling channels with two layer of tapered edge gypsum board (conforming to IS 2095 Part 1 : 2011) fixed with GI studs on both sides. All drywall partitions should have the duty ratings as specified under BS 5234 part 2. The detail specifications and methodology are listed below. Floor and ceiling channel made of GI steel to be anchored to the floor and true ceiling using HILTI HLC8x40 / HILTI X - GN20MX anchor fasteners at 600mm c/c in zigzag manner. Floor channel to be wrapped with 70μ Self Adhesive LDPE moisture barrier film to further improve corrosion resistance performance. The gaps between floor and flooring channel, true ceiling and ceiling channel should be covered with fire sealant. C stud of 0.5mm thick having one flange of 34mm and another flange of 36mm made of GI Steel to be placed at the spacing specified below, in between floor and ceiling channel. Stud and floor channel are crimped together with crimping tool. Noggin channel of suitable width and 0.5mm thick having two flanges of 40mm each has to be provided at the horizontal joints of outer layer boards screw fixed to the studs using metal to metal flat head screws. 50mm thick Mineral wool or polyester wadding of density not less than 48 kg/m3 shall be placed in metal framework. Holding clip should be used to hold polyester wadding in its position. The gyp boards are to be fixed with Drywall Screws of 25mm and 50mm at minimum spacing of 300mm at Centre and 150mm at periphery of wall to either side of the stud. The gyp boards to be placed vertically to the framework, with joints staggered to avoid leakage through joints. Finally square and tapered edges of the boards are to be jointed and finished so as to have a flush look which includes filling and finishing with Jointing compound confirming to ASTM C 475 and fibre mesh joint tape as per the manufacturer's specifications. Joint finishing to be done for both 1st and 2nd layers of gyp board All the GI channels and sections should be finished with minimum 120 GSM as per IS 277. Coating with AZ150 as per IS 15961 will be added advantage. All dry wall screws should be made of Carbon steel confirming to EN-ISO 7049/50 and finished with Case hardened Grey Phosphating CLASS 48 as per EN 14566. All metal to metal screws should be made of Carbon steel confirming to EN-ISO 7049/50 and finished with minimum Zinc Coating Thickness of 4.14micron.

-

-

-

... More
Note: 1. The junction of the partition with masonry and all penetration through the partition has to be treated with Hilti/Pyroplex acoustic sealant. 2.Vendor has to submit detail specifications with shop drawing for approval. 3. No Deductions for the horizontal service penetrations. 4. Deductions to be considered for Doors and Windows. 5. Control Joint has to be provided at every 10 Mtr. c/c. along the length of wall. 6. Necessary GI stud backing to be provided for handing the soft board / white board panels. 7. Thickness of partition, size of stud and channel to be as listed below 8. The supplier / manufacturer should submit a guarantee certificate for required acoustic performance and stability. 9. The supplier / manufacturer should inspect the site to ensure that the executed works are adhered to the specification and should submit a guarantee certificate for required acoustic rating. 10. Mineral wool or polyester wadding will be paid separately under respective items. 11. Rate to include for curve/ circular and any other shape etc., Rate to include providing GI angle bead at all L-Junctions of partition, Nogging channels at the horizontal joints of each boards, GI stop beads around the door openings, providing necessary GI sections backing / Cutting for switches and sockets, additional supports near the openings, wood inserts for fixing joinery, necessary sound deadening membrane to achieve the required acoustics etc., Quoted rate to be inclusive of all the works mentioned above with standard drywall partitions accessories. Actual laid area from floor to true ceiling will be measured and paid. Working at all levels and heights etc., Complete complying with standard specifications and as directed by the "Engineer-in-charge/Architect". Note: To quote only for GI Sections with necessary accessories as mentioned above

-

-

-

... More
With 50mm floor and ceiling channels and 48mm C stud placed 610mm c/c to a maximum height of 3.6 meters

1710

-

-

... More
First skin / Second Skin : Providing and Fixing of Gypboard to the Aluminium / GI partitions and the joints between the gyp-boards are fixed with 25mm drywall screws at 300mm center to center and are finished flush with jointing compound and paper tape, top coat, necessary accessories and all as per manufacturer’s specification etc. complete and as directed. Rate inclusive of fixing with necessary accessories, cutting for switches and sockets, necessary GI backing etc., Complete complying with standard specifications and as directed by the "Engineer-in-charge/Architect". Mode of measurement - Actual laid area will be measured and paid. Deduction will be made for Writing board / Soft board in the second skins. Note: The second layer should be fixed in staggered pattern to keep away the joints of first and second layer. Note: To quote only for Gypsum boards along with necessary accessories as mentioned in the above description for dry wall partition / paneling works.

-

-

-

... More
12.5mm thick plain gypsum board of density not less than 640 kgs /m3

5000

-

-

... More
12.5mm thick Impact Resistance Gypsum Board of density not less than 640 kgs /m3

536

-

-

... More
First skin / Second Skin : Providing and fixing of exterior grade MDF board., with 25mm drywall screws at 300mm center to center to the Aluminium/ GI Sections in staggered pattern. The joints to be smoothly finished without undulations. Rate inclusive of fixing with necessary accessories, cutting for switches and sockets etc. Working at all levels and heights etc., Complete complying with standard specifications and as directed by the "Engineer-in-charge/Architect".

-

-

-

... More
6mm thick

296

-

-

... More
8mm thick

20

-

-

... More
11mm thick

20

-

-

... More
18mm thick

20

-

-

... More
Specification same as above but the partition shall be of partition / curved partition / circular column paneling with flexi ply of 4mm thick instead of straight etc., Complete complying with standard specifications and as directed by the "Engineer-in-charge/Architect".

132

-

-

... More
First skin / Second Skin : Providing and fixing of exterior grade BWR ply., with 25mm drywall screws at 300mm center to center to the Aluminium/ GI Sections in staggered pattern. The joints to be smoothly finished without undulations. Rate inclusive of fixing with necessary accessories, cutting for switches and sockets etc. Working at all levels and heights etc., Complete complying with standard specifications and as directed by the "Engineer-in-charge/Architect".

-

-

-

... More
6mm thick

236

-

-

... More
9mm thick

27

-

-

... More
12mm thick

434

-

-

... More
16mm thick

20

-

-

... More
19mm thick

20

-

-

... More
Providing and fixing of 1mm thick laminate as shown in the Architectural Drawing from approved color and shade with grooves and lines and in patterns on specified area as instructed by Architect / Client. The cost of necessary hardware's, adhesives, wastages etc., as required for complete the works. Actual visible surfaces only will be measured and paid. Working at all levels and heights etc., Complete complying with standard specifications and as directed by the "Engineer-in-charge/Architect".

-

-

-

... More
1mm thick laminate of approved color and shade

50

-

-

... More
1mm thick laminate of approved color and shade

15

-

-

... More
Providing and fixing of 4mm thick veneer as shown in the Architectural Drawing from approved colour and shade with grooves and lines and in patterns on specified area as instructed by Architect / Client, exposed surfaces of veneer shall be finished with approved Polyurethane polish. The cost of necessary hardware's, adhesives, wastages etc.; as required for complete the works. Actual visible surfaces only will be measured and paid. Working at all levels and heights etc., Complete complying with standard specifications and as directed by the "Engineer-in-charge/Architect".

-

-

-

... More
4mm thick veneer of approved colour and shade

70

-

-

... More
4mm thick decorative veneer of approved colour and shade

20

-

-

... More
Providing and fixing of Magnetic writing board and Wall panels with lacquered glass of approved colour from Saint Gobain or approved equivalent make., over the partition, paneling or wall surfaces as shown in the Architectural Drawing. The glass should be Premium GRIHA rated, PU lacquered and opaque with low VOC, Uniform coating, humidity proof and high durability. The rate shall be inclusive of necessary fixing with SCG Glassmate ultrafix sealant or approved equivalent make as specified by manufacturer. Working at all levels and heights etc., Complete complying with standard specifications and as directed by the "Engineer-in-charge/Architect".

-

-

-

... More
4mm thick Annealed lacquered glass with SGG Planilaque Evolution series or approved equivalent make

19

-

-

... More
6mm thick Annealed lacquered glass with SGG Planilaque Evolution series or approved equivalent make

41

-

-

... More
6mm thick Toughened lacquered glass or approved equivalent make as per manufacturers specification.

13

-

-

... More
6mm thick Annealed lacquered glass with SGG Planilaque Metallic and Pastel series

13

-

-

... More
Supply and installation of acoustic wall panels to a recycled PET/ Wood wool / Polyester fabric, fixed over the existing partitions / walls with adhesives. Spacing between the panels to be as per manufacturer's specification. Rate shall be inclusive of adhesives, brackets, wastages, all accessories and scaffolding at all heights. Rate to include wall mounting hardware with peripheral edge trim - Aluminum Anodised U or T shaped 6mm profile etc., Complete complying with standard specifications and as directed by the "Engineer-in-charge/Architect".

-

-

-

... More
6mm thick

282

-

-

... More
12mm thk

29

-

-

... More
Specification same as above but with printed designer or 3D panels.

12

-

-

... More
Supply and fixing of 6 mm thick Acrylic solid surface Band with or without pen tray niche, over 6mm thick exterior grade BWR Ply backing. All the exposed surface to be covered with acrylic solid surface as shown in the drawing. The exposed edges and corners shall be chamfered to a width of 1mm to avoid sharp edges. Rate shall be inclusive of 6mm solid surface, necessary accessories, sealant for joint finish, adhesives for fixing, buffing/ polishing., complete., Working at all levels and heights etc., Complete complying with standard specifications and as directed by the "Engineer-in-charge/Architect". (BWR ply measured under relavent item). Basic Cost of Acrylic solid surface

7

-

-

... More
Specification same as above but 12mm thk Acrylic solid surface Band

17

-

-

... More
Providing and fixing Pinup soft board of as shown in the Architectural Drawing., with 12mm thick soft board panels wrapped with fabric of approved shade. The board shall be fixed on prepared surface with necessary hardware fittings etc. complete. All around the soft board shall be covered with approved 12X12mm Aluminium anodised trims. Rate quoted shall be for the complete finished work, including all the materials and labour mentioned for complete installed work. Working at all levels and heights etc., Complete complying with standard specifications and as directed by the "Engineer-in-charge/Architect".

75

-

-

... More
Designing, supplying and fixing of Digitally reproduced Scotch print decorative 3M graphics wall paper (with controltac & comply feature for direct, bubble-free application on walls) as per the theme selected by clients with UV protective matte over laminate. Customized imagery. The rate shall be inclusive of necessary designing, colour printouts for approval, mockup as required by Engineer-in-charge/Architects/PM/Clients, material, Hardware for fixing, charges etc., Complete complying with standard specifications and as directed by the "Engineer-in-charge/Architect".

52

-

-

... More
Providing and fixing of Niche for TV with 16.5mm thick exterior grade MDF board to the existing Aluminium partition and finished as per detail drawing. Depth shall be maximum 300mm. Rate to include 16.5 MDF, Adhesives, screws and wastages complete., Working at all levels and heights etc., Complete complying with standard specifications and as directed by the "Engineer-in-charge/Architect". Height and width of the niche will be measured and paid.

21

-

-

... More
Supply and Installation of linear wall cladding system made of Aluminium box sections with wood finish. The size of the panel shall be 25 X 100 mm made of 0.5mm thk Aluminium rectangle profiles. The system shall be supported by necessary runners, stiffeners and carriers as per manufacturer's specification etc. The rate quoted for wall panel system shall include scaffolding arrangement, providing necessary supports, cutouts for all fixing light fixtures (all sizes) AC diffuser, and any other openings to be made in wall panel etc., Complete complying with standard specifications and as directed by the "Engineer-in-charge/Architect".

9

-

-

... More
Supply and fixing of wall cladding of panel sizes of 330mmx2650mm x 8mm, resistant to moisture & water. It is durable, scratch resistant EN 438-2 p.25, non-flaAlbansble EN 13501-1 BS 476 part 7, imparct resistance, not less than 3J (23,03), reaction to fire C-s3:d0, in accordance with regulation (EU) no. 305/2011 under the sole responsibility of the manufacturer. Increases the sound insulation EN ISO 140-4 EN ISO 717-1 of the room, thermal conduction EN 12664, UV resistance EN ISO 4892-2 EN 20105-102, Global migration to food substances. Safe in contact with food EN 1186-1 EN 1186-3 EN 1186-14 and does not contain lead and tin.

-

-

-

... More
No Emissions of harmful substances ISO 16000. The panels will be fixed flush fit with tongue and groove system and McCoy Soudal Fix All high tack bonding adhesive seal to ensure proper adhesion to the wall. Should be non toxic substances, and made made of recycledmaterials and 100% suitable for recycling etc., Complete complying with standard specifications and as directed by the "Engineer-in-charge/Architect".

9

-

-

... More
Supply and Installation of 122mm thick Two hours fire rated GI stud partition which includes two layer of tapered edge 12.5mm thick Fire rated gypsum board (conforming to IS 2095 Part 1 : 2011 ) of density not less than 750 kgs /m3 fixed with 70mm GI acoustic studs on both sides. All drywall partitions should have the duty ratings as specified under BS 5234 part 2. The detail specifications and methodology are listed below. Floor and ceiling channel of 72mm width and 0.5mm thick have equal flanges of 32mm made of GI steel to be anchored to the floor and true ceiling using HILTI HLC8x40 / HILTI X - GN20MX anchor fasteners at 600mm c/c in zigzag manner. Floor channel to be wrapped with 70μ Self Adhesive LDPE moisture barrier film to further improve corrosion resistance performance. The gaps between floor / flooring channel, ceiling / ceiling channel should be covered with fire sealant. Acoustic C stud of 0.5mm thick having one flange of 34mm and another flange of 36mm made of GI Steel to be placed at 610mm Centre to Centre in between 72mm floor and ceiling channel. Stud and floor channel are crimped together with crimping tool. Noggin channel of 70mm width and 0.5mm thick having two flanges of 40mm each has to be provided at the horizontal joints of outer layer boards screw fixed to the studs using metal to metal flat head screws. 50mm thick polyester wadding of density not less than 50 kg/m3 shall be placed in metal framework. Holding clip should be used to hold polyester wadding in its position. The fire line gyp boards are to be fixed with Drywall Screws of 25mm and 50mm at minimum spacing of 300mm at Centre and 150mm at periphery of wall to either side of 70mm stud. The gyp boards to be placed vertically to the framework, with joints staggered to avoid leakage through joints. Finally square and tapered edges of the boards are to be jointed and finished so as to have a flush look which includes filling and finishing with Jointing compound confirming to ASTM C 475 and fibre mesh joint tape as per the manufacturer's specifications. Joint finishing to be done for both 1st and 2nd layers of gyp board All the GI channels and sections should be finished with minimum 120 GSM as per IS 277. Coating with AZ150 as per IS 15961 will be added advantage. All dry wall screws should be made of Carbon steel confirming to EN-ISO 7049/50 and finished with Case hardened Grey Phosphating CLASS 48 as per EN 14566. All metal to metal screws should be made of Carbon steel confirming to EN-ISO 7049/50 and finished with minimum Zinc Coating Thickness of 4.14micron etc., Complete complying with standard specifications and as directed by the "Engineer-in-charge/Architect". Note: 1. The junction of the partition with masonry and all penetration through the partition has to be treated with fire sealant. 2.Vendor has to submit detail specifications with shop drawing for approval. 3.The supplier / manufacturer should inspect the site to ensure that the executed works are adhered to the specification and should submit a guarantee certificate for required fire and acoustic rating. 4. No Deductions for the horizontal service penetrations. 5. Deductions to be considered for Doors and Windows. 6. Control Joint has to be provided at every 10 Mtr. c/c. along the length of wall. 7. Necessary GI stud backing to be provided for holding the soft board / white board panels.

-

-

-

... More
Rate to include providing GI angle bead at all L-Junctions of partition, Nogging channels at the horizontal joints of each boards, GI stop beads around the door openings, providing necessary GI sections backing / Cutting for switches and sockets, additional wood inserts near the openings, necessary sound deadening membrane to achieve the required acoustics etc., Quoted rate to be inclusive of all the works mentioned above with standard drywall partitions accessories. Actual laid area from floor to true ceiling will be measured and paid.

10

-

-

... More
Providing and fixing of 50mm thick Rock wool of density 48 kgs/m3 wrapped with 40GSM fiber glass tissue in drywall partition with holding clips to make it as acoustic proof. It shall be placed in the Aluminium frame cavity. The contractor must ensure that the wool is either wire-braced or holded with clips to prevent it from ‘lumping down’ over a period of time. Working at all levels and heights etc., Complete complying with standard specifications and as directed by the "Engineer-in-charge/Architect".

1826

-

-

... More
Providing and fixing louver panelling of full height for existing DB by using MDF16mm board and louver shutter laminated with approved shade with necessary hinges etc., Working at all levels and heights etc., Complete complying with standard specifications and as directed by the "Engineer-in-charge/Architect".

5

-

-

... More
Wooden Acoustic Wall Panels

-

-

-

... More
Supply & installation of Anutone Salon Slats Surco made of pinewood E1 grade fiberboard, melamine laminated finish, groove perforated slats L16-2 - (2mm grooves @16mm pitch with 27% open area), backlined with Soundtexblack acoustical fleece of 0.27mm thick, surface density 63g/m2,rear scoring with perf 10mm at 20mm pitch, tongue-groove edge for a seamless look, flame resistant (BS476 part 7) , of size 128 x2440x16mm, volume density of base board 700Kg/m3, weight 9Kg/m2 (L16), installed by using GI Strut framework system.The GI Strut framework system shall include Strut CC25, fully knurled, sectional thickness 0.45mm, length 3600mm, web 50mm, depth of 25mm and equal flanges 15mm is fastened to the wall positioned horizontally or vertically at every 600mm centres.Anutone Strut CC18,aluminium core cross channel, thickness 0.5mm, length 2400mm, web 15mm & 27mm, depth 18mm and flanges of 7mm with suitable edge & center brackets is then fixed perpendicular to the Strut CC25 with the help of fasteners at every 400mm centers Anutone Slats Surco Plus of size 128x 2440x16mm in then fixed perpendicular to Strut CC18 with suitable edge & centre brackets. The system is backlined with Anutone SynthPF 5x25 adhered on wall with dab spots of Anutone stick S7 adhesive. Technical Parameters Fire (Class) – BS476 part 7 , Acoustics – NRC 0.75, Thermal conductivity (W/mk)– na, Climate (°C, RH) – 50, 70, Light reflectance (%) – 75 (Maple Arce),Green (VOC, RC %) – E1, 25 etc., Complete complying with standard specifications and as directed by the "Engineer-in-charge/Architect".

65

-

-

... More
Supply and installation of Anutone Acoustic wall fabric stretch system by using FR Grade fabric of size 1400mm width, shall be stretched by using CC 25 with infill of synth pf 5X25 mm thick, rigid vinyl Stretch Tracks half wrap/full wrap 15mm (FS15) and Midseam 15mm (FS15), strand board, synth PF infill with requisite accessories & tools. CC 25 mm is first installed on the wall along with ithe marking lines with metal fasteners inserted at 300mm centers . FS15 tracks to be installed on wooden base, after applying Stick S7 adhesive on both surfaces for a true and continuous secure grip, and heavy-duty fasteners at 150mm centers on one/both sides of Stretch Tracks.Strand3 Fibre square edge magnesite bonded pinewood fiber panels of size 600x1200x20mm having density 400kg/m3, weight 4kg which is fixed to wall with suitable fasteners. Synth PF 5x25mm thick adhered on strand panel by using Stick 7 adhesive. Fabric of width 1400mm is then aligned to the Stretch tracks by following the fabric thread line or pattern. The fabric is stretched and tucked into the Stretch tracks and secure into the locking jaws so that it will be smooth, free of wrinkles with the tucking tools. Note -minimum 50mm additional fabric is required for tucking hence maximum module wall fabric width would be 1300mm. Technical parameters : Core - pinewoodfibre & polyfibre, Fire – 1, Acoustics – NRC 0.90, Climate (OC RH) – 49, 90, Termite resistance – Yes, Light reflectance – Colour dependent, Green (RC %) – 25, Hygiene (VoC, Clean room) – Low, Class 1 etc., Complete complying with standard specifications and as directed by the "Engineer-in-charge/Architect".

65

-

-

... More
SINGLE GLAZED TOUGHENED GLASS PARTITIONS - 45 FRAME PROFILES

-

-

-

... More
Supplying and fixing of Slim Glass partition of 10mm Toughened Glass using Dormakaba Alexa System-45 Frames to a height of maximum 3m or as per drawing.The Fixed glass to be fixed using Dormakaba Alexa BP45 Profiles at Top & Bottom & Alexa SP45 at sides. The profile size to be 45x25MM to be fixed on to the floor/wall/ ceiling as per the architect design. Dormakaba Alexa H Junction profile to be used at all Glass to Glass vertical joints, 90 Deg L Junction Profiles and T Junction profiles necessary as per design.In case of Glass overall panel Alexa MP45 & BP45 Overpanel Profile to be used

-

-

-

... More
In case of Open glass edges EP45 End Profile to be used. The Alexa profiles shall be suitable for Glass thickness of 10/12/13.52mm.The Profile shall be matt natural anodized, the Profile Manufacturer to supply all the necessary clips, seals and fixing accessories for the system. All Profiles to be with 2mm Gauge thickness Excluding 20 Micron of Anodizing. Approved Manufacturer: Profiles/Frames: Dormakaba, Glass : Saint Giobain/Asahi etc., Complete complying with standard specifications and as directed by the "Engineer-in-charge/Architect".

143

-

-

... More
Designing, Printing, Supply and Fixing of Frost film to glass partitions using 3M frosted film stickers as per required pattern and shape and as directed. Cost inclusive of designing, mockup and installation with all accessories. The vendor must submit required warranty certificates from the manufacturer. Working at all levels and heights etc., Complete complying with standard specifications and as directed by the "Engineer-in-charge/Architect".

39

-

-

... More
Supply & Installation of 300mm wide Technical Power portal using Double Glazed X-Series partition systems of 105 x 25mm thk section using JEB 1004A as Horizontals at top & Horizontals at bottom and JEB 859 verticals with solid partition from FFL upto 2800mm Complete in all respect considering two layer of using ACP Sheet panel with 9mm Ply Backing with Rock wool & RP Tissue etc., Complete complying with standard specifications and as directed by the "Engineer-in-charge/Architect".

2

-

-

... More
Supply and Installation of CNC cut designer board with the materials as listed below. The designer board to be fixed with necessary aluminum supports / suspended hangers, wires etc. Area of the perforated screen will be measured and paid. Design to be approved by Architects. Working at all levels and heights etc., Complete complying with standard specifications and as directed by the "Engineer-in-charge/Architect".

-

-

-

... More
With 12mm thick Acrylic solid surface of approved shade.

2

-

-

... More
With 20mm thick acoustic panels of approved shade and texture.

2

-

-

... More
With 12mm thick acoustic panels of approved shade and texture.

2

-

-

... More
With 24mm thick acoustic panels of approved shade and texture.

2

-

-

... More
Fabricating, supplying and installing of 3mm thick Sintered porcelain slab- PDS Grigia of STONELAM make with factory embeded fibre mesh backing. Sintered porcelain slabs to have 25years warranty against natural degradation. Standard panel size to be 1mtr x 3mtr and will be cut to size as per architectural intent/ approved drawings. Installation system Designed to withstand wind pressure of Kpa. The porcelain stoneware cladding panels are structurally glazed to aluminium frame work with structural sealant of approved make and VHB tape. the glazed panels will be fixed to the aluminium grid work using suitable brackets as indicated in the tender drawings, the aluminium grid work is fixed to the dead wall. beam, column etc. with MS hot dip galvanised brackets at intervals as per structural requirement, the vertical and horizontal grooves will be sealed with weather sealant of approved make as indicated in the tender drawings. All exposed aluminium surface to be with PPC finish matching to the colour of porcelain stoneware, All aluminium to be anodized finish. Rate to include all expenses including wastage/labour/supply and installation as per technical specification and approved shop drawings. Working at all levels and heights etc., Complete complying with standard specifications and as directed by the "Engineer-in-charge/Architect".

-

-

-

... More
False Ceiling Works

-

-

-

... More
Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, Including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification etc., Including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed. but excluding the cost of painting with etc., Complete complying with standard specifications and as directed by the "Engineer-in-charge/Architect".

-

-

-

... More
12.5 mm thick tapered edge gypsum moisture resistant board - Any shape

838

-

-

... More
Providing and Fixing 15 mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per sqm including both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross “T” of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main’T’ at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross ‘T’ of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel of size(24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws @ 230 mm interval and laying 15 mm thick densified edges calicum silicate ceiling tiles of approved texture in the grid, including, cutting/ making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required. Main ‘T’ runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main ‘T’, bottom exposed with 24 mm of all Tsections shall be pre-painted with polyster baked paint, for all heights etc., Complete complying with standard specifications and as directed by the "Engineer-in-charge/Architect".

-

-

-

... More
Note :- Only calcium silicate false ceiling area will be measured from wall to wall. No deduction shall be made for exposed frames/ opening (cut outs) having area less than 0.30 sqm.The calcium silicate ceiling tile shall have NRC value of 0.50 (Minimum), light reflection 85%, non- combustible as per B.S. 476 part IV, 100% humidity resistance and also having thermal conductivity 0.043 w/ mK.

10

-

-

... More
Supply and Installation of Acoustic Mineral Fiber Grid Ceiling tiles with 0.7 NRC with T Grid Sections. The grid sections should be inter locking metal grid of hot dipped galvanised steel regular T grid sections (galvanized @ 90 gsm/sqm) consisting of Main "Tee", size 3600 x 38 x 0.30 mm made from 0.30 mm thick (minimum) sheet spaced at 1200mm center to center and Cross "Tee", size1200 x 38 x 0.30 mm made of 0.30 mm thick (minimum) sheet to be interlocked between the main T runners at the distance of 600mm center to center to create 1200x600mm module. Cross "Tee", size 600 x 38 x 0.30 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600mm module to form grids of 600x600mm to lay ceiling tiles. The perimeter trims to be of 22W x 19H x 3000L mm. Main "Tees" to be suspended from ceiling using GI slotted cleats fixed to ceiling with 6mm dia and 50mm long anchor fasteners, 4.00mm GI adjustable rods with galvanized level clips spaced at 1200mm center to center along the Main Tee. The 4.00mm GI rods should be in accordance to IS 280:2006 and should have a zinc coating of not less than 90 gsm in accordance with IS 4826:1986 and a tensile strength of 300-550 MPa in accordance to IS 1608:2005. The first suspension from the perimeter trim should not exceed 300mm. The bottom exposed width of 15 mm of all T-sections shall be pre-painted with polyester paint. Installation of Mineral Fiber Ceiling Tiles with square edges, 15 mm thick of size 600 x 600 mm with the criteria as listed below. The mineral fiber ceiling tile shall be firmly bonded wet-felt mineral wool tiles ,primed on both sides and appropriately finished on the visible side in white color similar to RAL 9010. The tiles are asbestos and formaldehyde free. The system must comply with Green building norms. NRC -0.7 as per ASTM C 423 Light reflectance - 85% min Humidity resistance - upto 95% RH Sound absorption - αw = 0.9 as per EN ISO 11654(3rd party certificate mandatory) Sound attenuation - Dn,f,w= 38 dB as per EN ISO 10848

-

-

-

... More
The rate quoted for false ceiling system shall include scaffolding arrangement at all levels and heights, providing necessary cut-outs for all fixing light fixtures (all sizes) AC diffuser, AC dampers, AC linear grills, smoke detectors, speakers, etc. and any other openings to be made in false ceiling as directed by the "Engineer-in-charge". Mode of Measurement :Deductions in measurements will be calculated on full tile basis where light fittings & diffusers are installed instead of ceiling tiles. (No detection for sprinkler, fire detector, smoke sensor and other small ceiling mounted equipment) etc., Complete complying with standard specifications and as directed by the "Engineer-in-charge/Architect".

173

-

-

... More
Supply and Installation of Aluminium Perforated metal ceiling System of approved make., consisting of 600x600mm Lay in tiles of pre coated Aluminium in 0.5 mm thickness in white colour with standard perforation of 2.5mm dia & open area of 16% and Freudenberg Soundtex acoustical fleece glued to the back of the tile to be laid on grid systems with 15mm wide T - section flanges having rotary stitching on the Main Runner, 1200 mm & 600 mm Cross Tees. The T Sections have a Galvanizing of 120 grams per M2 & passed through 500 hrs of Salt test. The grid to be formed using hot dipped galvanized steel section, exposed surface chemically cleaned capping pre-finished in baked polyester paint wall angle of size 3000mmx19mmx19mm used in the periphery of the ceiling fixed to the wall partition / RC Column / band walls with the help of screws at 600mm C/C. Main runner spaced at a 1200mm C/C suspended by using 3mm dia G.I. wire hanger securely fixed to soffit if RCC slab. GI hanger to be placed every 1200mm(max) and 1200mm long cross tee to be interlocked between in Main runner at 600mm C/C (max) to form a grid of 1200mmx600mm. 600mm long cross tee fixed in between 1200mm long cross tee for forming a grid of 600mm x 600mm,The tiles should have Humidity Resistance (RH) of 100%, NRC of 0.70, Fire Performance A2-s1.d0 in module size of 600 X 600 mm, suitable for Green Building application, with Recycled content of 50%. The Tile & Grid system used together should carry a 15 year warrantee.

-

-

-

... More
The rate quoted for false ceiling system shall include scaffolding arrangement at all levels and heights, providing necessary cut-outs for all fixing light fixtures (all sizes) AC diffuser, AC dampers, AC linear grills, smoke detectors, speakers, etc. and any other openings to be made in false ceiling as directed by the PMC/Architect. Mode of Measurement :Deductions in measurements will be calculated on full tile basis where light fittings & diffusers are installed instead of ceiling tiles. (No detection for sprinkler, fire detector, smoke sensor and other small ceiling mounted equipment) etc., Complete complying with standard specifications and as directed by the "Engineer-in-charge/Architect".

27

-

-

... More
Supply and Installation of Aluminium open decorative linear ceiling suspension system of Fame line or approved Equivalent make, with wood finish from approved make as shown in the Architectural Drawing. The size of the panel shall be 25 X 100 mm made of 0.5mm thk Aluminium U profiles. The suspended system shall be supported by necessary hangers, carriers made of 0.5mm thk galvanised steel. The suspended supports are fixed at a distance as recommended by manufacturer. The carriers are then fixed to the suspended supports, the panels are then fixed to the carrier with easy clip in method. The system should posses easy removing and refixing method for checking and maintenance purposes.

-

-

-

... More
The rate quoted for false ceiling system shall include scaffolding arrangement, providing necessary cut-outs for all fixing light fixtures (all sizes) AC diffuser, AC dampers, AC linear grills, smoke detectors, speakers, etc. and any other openings to be made in false ceiling, Working at all levels and heights etc., Complete complying with standard specifications and as directed by the "Engineer-in-charge/Architect".

1168

-

-

... More
Acoustic False Ceiling

-

-

-

... More
Supply and Installation of Subtex Ebony square edge Glass fibre core fully encapsulated ceiling tiles of size 595x595x15mm having density 100-120Kgs/m3, weight 1.5-1.8kg/m2 which is suspended by using 0.3mm thick and 15mm wide pre coated metal T15 Ebony grid system.The T15 Ebony Grid system of 600x1200mm module shall include wall angle (WA15B30) with unequal flanges of size 14&20mm wide, length 3000mm, 0.43mm thick fixed along the perimeter of walls with the help of nylon sleeves and suitable fasteners at 300mm centers. Then suspend the Main T15 (MT15B36) having flange width 15mm, height 32mm and length 3600mm from the soffit with help of soffit cleat and wire rod with leveling spring clip at 1200mm c/c. Cross T15 (CT15B12) having flange width 15mm, height 32mm and length 1200mm is then interlocked into the pre-cut slots in the Main T15 at 600mm centers in the direction perpendicular to the MainT15. Subtex Ebony square edge of size 595x595x15mm thick shall be placed into the grid size of 600x600mm. Ensure arrow marks behind subtex panels are oriented in one direction to achieve uniform shade. Technical Parameters Core - Glassfibre, Fire – Class 1 & P, Acoustics – NRC 0.9, Climate (OC RH) – 40, 95, Termite resistance – Yes, Light reflectance – Low , Green (RC %) – 35, Hygiene (VoC, Clean room) – Low, Class 3, Strength, Load capacity (Kg) - Antisag etc., Complete complying with standard specifications and as directed by the "Engineer-in-charge/Architect".

127

-

-

... More
Supply and Installation of custom designed metal baffle ceiling with Spacing – Random Spacing as per Design as shown in the drawing with specifications listed below Supply and Installation of Baffle ceilings with Architect approved Wood Finish of 100mm(Height) x 40mm/ 50mm/ 100mm / 150mm (Mixed Size Base) x 1.2mm thick extruded Aluminium suspended at a center to center distance of 150 mm to the baffle C Carrier. The baffle is connected the Baffle Carrier with a bolt/nut/Spring washer arrangement as per typical detail attached. The baffle C Carrier is suspended at every 1m in general and at 150mm from Baffle Joints. The baffles come at a maximum size upto 4.3m in length. The baffle end with an End Cap made in Aluminium and is with same finish as the baffle panel. Baffle spacing and fixing arrangement is to be done as per architect’s design and approval. The rate quoted for false ceiling system shall include scaffolding arrangement, providing necessary cut-outs for all fixing light fixtures (all sizes) AC diffuser, AC dampers, AC linear grills, smoke detectors, speakers etc and any other openings to be made in false ceiling as directed etc., Complete complying with standard specifications and as directed by the "Engineer-in-charge/Architect".

-

-

-

... More
40mm base

5

-

-

... More
50mm base

5

-

-

... More
100mm base

5

-

-

... More
150mm base

5

-

-

... More
Supply and Installation of Custom Design Baffle ceiling consists of 25x50mm extruded aluminium box section profile with extruded end connector at both ends and a hexagon shaped Extruded aluminium column with six notches along the circumference. The hexagon shaped column is positioned as per size of the equilateral triangle approved and suspended to the true ceilings using 8mm threaded rod and a carrier. The 25x50mm extruded aluminium box sections are cut to required approved size and special extruded end connector is fixed at both the ends of the cut baffles. Each of this box section is then inserted on to the six sides of the column and thereby forming a hexagonal shape as per the drawing. the box sections, columns and end connector are powder coated in solid colour/wood finish to required shade specified by the architect. The entire system consists of all aluminium extruded profile and when so installed form a rigid ceiling detail. Suspension by M6/M8 threaded rods anchored to the ceiling and connected to the extruded aluminium columns at every junction. Hexagon Caps in White colour are fixed at the bottom of the extruded columns to complete the ceilings etc., Complete complying with standard specifications and as directed by the "Engineer-in-charge/Architect".

5

-

-

... More
All the exposed surfaces to be finished with 4mm thick Veneer of approved shade with PU finish. Rate inclusive of Veneer, Adhesives for fixing and PU polish

9

-

-

... More
All the exposed surfaces to be finished with 1mm thick Laminate of approved shade . Rate inclusive of laminate, PVC edge beadings and adhesives

61

-

-

... More
Supply and Installation of Senses Acoustic suspended cloud Ceilings with extra coating for stain resistant as shown in the Architectural Drawing, from Senses Akustik suspended vertically with thickness not less than 35mm of approved colours to be hanged to the ceiling/ soffits etc., Complete complying with standard specifications and as directed by the "Engineer-in-charge/Architect". content : 100% wool felt, flexy ply dimensions : 400mm dia - 1200mm dia thickness :35mm thickness/dimension tolerance : +10% , -10% Hanging system: hardwares / clutch wire environmental 100% wool felt contains no formaldehyde, biodegradable,voc free, no chemical irritants, recyclable and free of harmful substances.acoustics : NRC - 0.85 Environmental - CII greenpro certified product, type 1colour fastness to light :- class 4-5 (40 hours ) .acoustics : nrc - 0.85 environmental - cii greenpro certified product, type 1colour fastness to light :- class 4-5 (40 hours ) .

-

-

-

... More
Hexagon of Sides 600mm with approved colour

5

-

-

... More
Circular type

-

-

-

... More
450mm dia

3

-

-

... More
600mm dia

15

-

-

... More
800mm dia

3

-

-

... More
900mm dia

2

-

-

... More
1200mm dia

2

-

-

... More
Supply and Installation of Acoustic suspended Baffle Ceilings as shown in the Architectural Drawing, from Senses Akoutik or approved equivalent make, suspended vertically with thickness not less than 20mm of approved colours to be hanged to the ceiling/ soffits. Baffles should be made up of Recycled PET or felt. The length of each baffle to be as per drawings and the spacing as per manufacturers specification or as directed etc., Complete complying with standard specifications and as directed by the "Engineer-in-charge/Architect". Must comply with the following criteria Sound absorption Test according to EN ISO 354 Sound absorption co efficient according to EN ISO 11654 NRC ratings according to ASTM C 423 Certificate for indoor climate labeling

-

-

-

... More
The rate quoted for baffle ceiling system shall include necessary cables, hangers, clips, anchor bolts, connecting clips and other accessories for hanging, scaffolding arrangement, wastages etc, Working at all levels and heights and as directed by Engineer- in- Charge. The length and height of the baffles will be measured and paid.

3

-

-

... More
Supply and Installation of Anutone Strand 1 color Magnesite bonded pinewood fibre core ceiling planks of size 600x1200x20mm having density 400 kgs/m3, weight 8kg/m2 which is fixed by using concealed ceiling framework system. Planks are factory-painted.The concealed ceiling system shall include GI Wall channel (WC22) having thickness 0.45mm, length 3600mm, unequal flanges of 20 & 30mm and web of 25mm should be fixed along the perimeters of the wall with nylon sleeves and suitable fasteners at every 300mm centers. Then suspend Main channels (MC45) having thickness 0.8mm, length 3600mm, equal flanges of 15mm and web 45mm from the soffit at every 1200mm centers with Suspender angle (SA25) having thickness 0.45mm, unequal flanges of 25 & 10mm. GI Cross channel (CC25) having thickness 0.45mm, length 3600mm, knurled web 50mm, depth of 25mm and equal flanges 9.5mm is fastened to the Main channel in the direction perpendicular to the Main Channel at every 600mm centers. Then panels to be screw fixed to the Cross channels.Technical parameter etc., Complete complying with standard specifications and as directed by the "Engineer-in-charge/Architect".

5

-

-

... More
Providing and Fixing of Click-Trap Access Panel of approved make., with unique locking system in ceiling. In general, exterior and interior framework made of stable Aluminium profile placed at bottom of the Gypsum ceiling level and shall be fixed using suitable metal drywall screws with nylon plugs etc complete. The access panel to have a 12mm thk fiber cement board door to receive paint (low VOC) or laminate finish & entire perimeter equipped with hard wearing insulating/ sealant tape and should be fixed in line with the nearby false ceiling. The rate shall be inclusive of all necessary accessories, hardware's like snap lock with spring loaded bolt of galvanised steel body, gypsum board with approved paint finish, laminate of approved shade, safety steel wire 1mm thk to prevents the door from falling, wastage etc, as required ,transport charges, handling, loading and unloading, Installation etc. Working at all levels and heights etc., Complete complying with standard specifications and as directed by the "Engineer-in-charge/Architect".

-

-

-

... More
Size 300mm x 300mm

17

-

-

... More
Size 450mm x 450mm

27

-

-

... More
Size 600mm x 600mm

21

-

-

... More
Size 1200mm x 600mm

4

-

-

... More
Providing and fixing of Axiom Perimeter trim of Armstrong or approved equivalent make with 150mm wide all around the suspended metal ceiling areas. The trims to be finished with factory made polyester paint of 50 microns minimum. Rate inclusive of all accessories like hangers, corner trims, splice plates, T bar connection clips for complete installation for the system including all accessories etc. Working at all levels and heights etc., Complete complying with standard specifications and as directed by the "Engineer-in-charge/Architect".

30

-

-

... More
Miscellaneous Works: Expansion Joints

-

-

-

... More
Supplying and applying of " CS" make line, this surface-mounted metal floor cover is designed for interior, new applications requiring movements up to 100%. The self-centering aluminum cover plate allows for thermal movement and seismic movement. with EPDM moisture barrier. Internal Floor to Floor / Floor to Wall expansion joints - 100mm wide. • Extrusion: model is extruded with 6063-T5, ASTM B221 • Sheet – 6061-T6, 3003-H14, 5005-H34, ASTM B209 • CS standard protective coating on aluminum surfaces to be placed in contact with Floor-to-Floor / Floor to Wall Joint Systems: 1. Basis-of-Design Product: Construction Specialties, Inc. model RFI 400 2. Type: Cover plate. 3. Cover Plate Design: Plain 4. Attachment Method: Mechanical anchors. 5. Load Capacity: Standard Duty 6. Moisture Barrier: EPDM Sheet.

12

-

-

... More
Supplying and applying of " CS" make line, this surface-mounted metal floor cover is designed for interior, new applications requiring movements up to 100%. The self-centering aluminum cover plate allows for thermal movement and seismic movement. with EPDM moisture barrier. Internal Floor to Floor / Floor to Wall expansion joints - 150mm wide • Extrusion: model is extruded with 6063-T5, ASTM B221 • Sheet – 6061-T6, 3003-H14, 5005-H34, ASTM B209 • CS standard protective coating on aluminum surfaces to be placed in contact with Floor-to-Floor Joint Systems: 1. Basis-of-Design Product: Construction Specialties, Inc. model RFI 600 2. Type: Cover plate. 3. Cover Plate Design: Plain 4. Attachment Method: Mechanical anchors. 5. Load Capacity: Standard Duty 6. Moisture Barrier: EPDM Sheet.

12

-

-

... More
Supplying and applying of " CS" make line, this surface-mounted metal floor cover is designed for interior, new applications requiring movements up to 100%. The self-centering aluminum cover plate allows for thermal movement and seismic movement. with EPDM moisture barrier. Internal Floor to Floor / Floor to Wall expansion joints - 200mm wide • Extrusion: model is extruded with 6063-T5, ASTM B221 • Sheet – 6061-T6, 3003-H14, 5005-H34, ASTM B209 • CS standard protective coating on aluminum surfaces to be placed in contact with Floor-to-Floor Joint Systems: 1. Basis-of-Design Product: Construction Specialties, Inc. model RFI 800 2. Type: Cover plate. 3. Cover Plate Design: Plain 4. Attachment Method: Mechanical anchors. 5. Load Capacity: Standard Duty 6. Moisture Barrier: EPDM Sheet.

16

-

-

... More
Supplying and applying of " CS" make line, this surface-mounted metal floor cover is designed for interior, new applications requiring movements up to 100%. The self-centering aluminum cover plate allows for thermal movement and seismic movement. with EPDM moisture barrier. Internal Floor to Floor / Floor to Wall expansion joints - 300mm wide • Extrusion: model is extruded with 6063-T5, ASTM B221 • Sheet – 6061-T6, 3003-H14, 5005-H34, ASTM B209 • CS standard protective coating on aluminum surfaces to be placed in contact with Floor-to-Floor Joint Systems: 1. Basis-of-Design Product: Construction Specialties, Inc. model SJPF 1200 2. Type: Cover plate. 3. Cover Plate Design: Plain 4. Attachment Method: Mechanical anchors. 5. Load Capacity: Standard Duty 6. Moisture Barrier: EPDM Sheet.

42

-

-

... More
Providing and fixing of 50mmx50mm size Column Corner Guard of approved make for vertical corner's of RCC columns, Brick pillars, Brick walls, Partitions, using sub frame of 1.5mm thick aluminium profile fixed in to the above corner surfaces by using anchor fasteners. Then the top covering with Rigid PVC panel profile is to be fixed on the sub frame by interlocking. The rate shall be inclusive of necessary hardware's etc., Complete complying with standard specifications and as directed by the "Engineer-in-charge/Architect".

119

-

-

... More
Supply and installation of Transition trims for walls at the junction of the glass / writing board / soft board / Wall paper as per detail drawing. The shape of trim shall be "U", "J", "T" or as per samples approved. Rate inclusive of cutting, necessary wastages and sealant/ adhesives for bonding. Sample to be submitted and approved before procuring. Finishing of trim as per drawing / Architect's approval etc., Complete complying with standard specifications and as directed by the "Engineer-in-charge/Architect".

-

-

-

... More
Aluminium anodised "T" shaped 5mm X 14mm (PCP135)

147

-

-

... More
Aluminium anodised "U" shaped 5mm X 14mm

174

-

-

... More
Aluminium anodised "L" shaped 5mm X 12.5mm (PFP124)

55

-

-

... More
Providing and fixing floor transition profiles for floors of approved make with sample section for the junction of tiles/ granite / Italian marble flooring / carpet to accommodate level variation. The top profile should be of approved shade. The base shall be screwed neatly to the flooring with SS screws and the top profile to be fixed as per manufacturers methodology. Finishing of trim as per drawing / Architect's approval etc., Complete complying with standard specifications and as directed by the "Engineer-in-charge/Architect".

-

-

-

... More
Minimum 20mm wide Aluminium anodised profiles

17

-

-

... More
Aluminium stair nosing - 24mmx9mm (SNP091)

13

-

-

... More
Providing and fixing of Barrier mat for DUST–BUSTER RECESS-ALUMINIUM MATTING (OPTIONS-GREY CARPET, BROWN CARPET) Model no 5014 from Euronics or Equivalent etc., Complete complying with standard specifications and as directed by the "Engineer-in-charge/Architect".

12

-

-

... More
Providing and fixing Pelmet made to shape and sizes as given in below, but in general it shall be made out of 18mm prelaminated MDF finished with white laminate or approved colour as directed. The rate shall be inclusive of necessary accessories like hangers rods/ Hilti anchor fasteners, sunken screws, all factory finished etc., Complete complying with standard specifications and as directed by the "Engineer-in-charge/Architect".

-

-

-

... More
Size of the pelmet shall be 200 X 200mm

75

-

-

... More
Providing and Fixing of Roller Blind should have sturdy aluminium top tube of 38mm diameter, powder coated bottom bar, with suitable roller clutch mechanism and plastic ball chain. The Roller Blind fabric should possess the below mentioned specifications etc., Complete complying with standard specifications and as directed by the "Engineer-in-charge/Architect".

-

-

-

... More
a) Openness factor - 5% b) Composition –35% fiberglass and 64% vinyl on polyester c) Core yarn should be Fiberglass d) Fabric thickness –0.43mm e) UV blockage – 95% f) MIF seal of approval g) Lead-free certified – RoHS compliant h) Flame Retardant – NFPA 701 and California US title 19 i) Anti-fungal / Anti-bacterial for lifetime – MICROBAN®product protection j) Environmental certification – GREENGUARD Gold certified k) Warranty – 10 years l) Approved make – Phifer

186

-

-

... More
Supplying and fixing the 5mm groove profile to differentitate the laminated sheet colours at wooden partition wall.The rate including supplying,cutting,grouve cutting pasting and fixing etc., Complete complying with standard specifications and as directed by the "Engineer-in-charge/Architect".

24

-

-

... More
Supply and Fixing Mirror as per drawing, in general 6mm thick mirror with aluminium frame at 600 mm c/c both ways for backing frame fixing with 12MM thick BWR ply and fixing with stainless steel studs. Rate quoted shall be for the complete item including all the materials and labour mentioned above. Rate to including all materials, labour changes, transportation, lead & Lifts, wastage etc., Complete complying with standard specifications and as directed by the "Engineer-in-charge/Architect".

14

-

-

... More
Standlone Indoor Planter

-

-

-

... More
Supply and fixing of indoor plants at 300mm dia FRP container with stand ,suitable weightless planting media , pebbles.cost includes indoor plants, planting media FRP container etc., Complete complying with standard specifications and as directed by the "Engineer-in-charge/Architect".

32

-

-

... More
Design, Supplying and Fixing of various signages are described below. The Colour, Font and Size should be approved by the Clients. Vendor to submit the samples required by Client for review and approval. The quoted rate shall be inclusive of required suitable fixing accessories and double sided adhesive tapes of 3M make or equivalent etc., Complete complying with standard specifications and as directed by the "Engineer-in-charge/Architect". Note: Please note that the proposal given are only for vinyl stickering with ACP / Acrylic base in consideration. However, should there be a requirement from the client end on the material finishes of the base, such as SS base / embossed and Size of the signboards, according to corporate identity there will be a variation in cost.

-

-

-

... More
Name and Numbers for Cabins, 4 Pax, 6 Pax, Server, UPS, Hub room Size: 12” x 3”, SS brush finish to be fixed double side 3M tape and with provision for slide on.

52

-

-

... More
Work Station signs: Size: 3" x 1.5". WS numbers Printed in Vinyl sticker.

13

-

-

... More
Server room signage Size: 12” x 4”, Foam Base vinyl sticker in colour as per design mounted on door with SS screws/ double side tape.

3

-

-

... More
Toilet sign: Size: 6” x 9”, Fabricated in Silver ACP Base with vinyl sticker with the Gents/Ladies pictograph

7

-

-

... More
Direction signs: Size: 12” x 4”, With clear Acrylic base Single sides sign of approved colour and Green base signs with electrical illumination with battery backup, to be hung by SS chain :

2

-

-

... More
PUSH, PULL Signage: Size 1.25" x 5", Brushed Stainless Steel Plate with the font embossed for all cabin doors

118

-

-

... More
Supply and Fixing of signage at entrance. Signage to be made of SS Plate with acid itch letter fixed with SS studs in main entrance. Size - 56" x 16" with necessary concealed fixtures.

1

-

-

... More
Supply, fabrication and installation of Logo at Reception based on the design intend. Cost to include for complete supply and installation including the light fixtures as per intend.

3

-

-

... More
Custom Made Furnitures

-

-

-

... More
Supply, Installation and positioning of Reception table made to shape and pattern as shown in the detail Architectural Drawing. The table top at 750mm with two layers of 12mm MDF backing and finished with 12mm thick Acrylic solid surface of approved shade. Sides, front and rear side shall be 1050mm height, made of two layers of 12 mm thick MDF board with adequate supports as directed in both horizontal and vertical directions and finished with Laminate. Approved laminate finish below the table top areas as shown in the drawing. The reception table to have extended table top to a length of 300mm on one side with vertical sides finished with 12mm acrylic solid surface of approved shade on both sides. The table to have two storage units with Box / Box drawer and file storage below with openable shutters as shown in the drawing. The table sides, storages and shutter are finished with veneer of approved shade. The inside storage units shall be finished with laminate and the exposed surfaces with Veneer. All the veneer to be finished with PU polish . The edges are finished with teakwood beading of approved shade. The table sides, storages and shutter are finished with veneer of approved shade. The inside storage units shall be finished with laminate and the exposed surfaces with Veneer. All the veneer to be finished with PU polish. The edges are finished with teakwood beading of approved shade. Table Size: 3500x750x900mm height Veneer, Laminate, & Acrylic Solid Surface

-

-

-

... More
Rate shall be inclusive of cutouts for electrical and data networks, wire manager, necessary wastages, hardware's like sliding runners, auto closing hinges, locking facility with three sets of keys for drawers and storage, PU polish, laminates, adhesive, buffing polishing etc., for complete installation as shown in the drawing etc., Complete complying with standard specifications and as directed by the "Engineer-in-charge/Architect".

1

-

-

... More
Supply and installation of Counter for Pantry and Cafeteria, with 12mm thick acrylic solid surface to a width not less than 750 mm and to a height as shown in drawing. The storage of countertop to be made of 19mm BWR ply with necessary stiffeners to withstand without sagging. The storages to be with minimum two rows of shelves, made of 12mm thick BWR ply with swing shutters with all necessary accessories like concealed auto closing SS hinges, tower bolts, locks (multi-purpose), ball catches, Aluminum profile recessed handle all complete., as directed. The all the exposed surfaces of storage should be finished with 1mm thick laminate of approved shade. PVC edge and corner beading of approved colour to be provided. Cost to include antitermite treatment / borer treatment. Rate to include all the works mentioned above including buffing, polishing, front facia, back splash, wastages cutting for the sanitary ware and fixtures, applying external grade colourless sealant in the joints between the wash basin / sink and granite, nosing, polishing at all heights and levels etc., Complete complying with standard specifications and as directed by the "Engineer-in-charge/Architect". Laminate: Acrylic solid surface -

-

-

-

... More
Mode of measurement: Length and Height will be measured and Paid

8

-

-

... More
Supply and installation of Running Counters as shown in the detail Architectural Drawing, The counter top to be 19 mm thick BWR plywood of approved shade with matching colour. The Counter top to be at 1050mm height, supported with epoxy powder coated MS Brackets and stiffeners with necessary accessories of approved colour. All the exposed & inner surfaces to be finished with 1mm thk laminate of approved shade with 1.5mm thick PVC edge banding. Working at all levels and Heights etc., Complete complying with standard specifications and as directed by the "Engineer-in-charge/Architect". Quoted rate to include all works mentioned above and as indicated in the drawing. Length and Depth of counter will be measured and paid

2

-

-

... More
Providing and fixing of Printer storage of 600mm depth with laminate storages below. The storage and supporting members to be made of Exterior grade MDF. Counter top with 25mm thick prelaminated ext grade MDF, Shutter and shelves with 12mm thick prelaminated ext grade MDF. The storages to have swing shutter, adjustable shelves, self closing hinges, recessed handles, lock etc., Quoted rate to include all the works mentioned above. Height and length will be measured and paid etc., Complete complying with standard specifications and as directed by the "Engineer-in-charge/Architect".

2

-

-

... More
Supply and installation of Over head storage as shown in the detail Architectural Drawing 400mm deep made of 18 mm exterior grade BWY ply. Storage to have necessary shelves and back of storage to be formed of 18mm exterior grade BWR ply with approved laminate. Swing Shutter made of 18mm exterior grade BWR ply with 2mm PVC lipping. Shutters to be provided with necessary hardware like spring loaded hinges, tower bolts, recessed handle, magnetic catchers, locks and three sets of keys etc., of approved make. The unit to be hung on the walls / partitions. All the exposed & inner surfaces to be finished with 1mm thk laminate. Cost to include antitermite treatment / borer treatment including primer and one coat of enamel paint. Quoted rate to include all the works mentioned above complete installation. Working at all levels and heights. Mode of Measurement : Height and length of OH Storage will be measured and paid etc., Complete complying with standard specifications and as directed by the "Engineer-in-charge.

107

-

-

... More
Providing and fixing Storage unit to a width of 600mm and height as per detailed drawing but in general, it shall be made out of 18 mm thick BWR plywood on all sides including top, with intermediate shelves to accommodate box files with necessary teakwood supports and the openable shutter shall be made out of 18mm thick BWR plywood etc. complete. All exposed surfaces shall be finished with 1mm thick approved laminate of approved shade and all inner / recessed surfaces shall have laminated with 1mm matching laminate. Rate to include all hardware's, auto closing cabinet heavy duty hinges, magnetic latch, SS handles - of approved make, including locking arrangements with master key of approved make etc., Complete complying with standard specifications and as directed by the "Engineer-in-charge/Architect". All factory finished. Height and Length will be measured and paid

22

-

-

... More
Providing, fabricating and fixing of stepped seating formed of 50mm x 50mm x 3mm MS framework placed at regular intervals (Horizontally, vertically, intermediately) as per site condition & as per details. Framework to be cladded with 19mm thick & ply surface finished with 4mm thick veneer of approved shade. Veneer surface to be finished with PU coat / polish of approved shade vertical side & front vertical side as per details. Necessary support take from true flooring and Wall surface as per site conditions. (Design / Profile as per drawing). All veneer surface to be finished with PU coat of approved shade as per details. i)Step Seating to be at 4 difference levels as per details Mode of Measurement only horizontal top surface will be measured in sqmt (L x W in Sqmt) and Veneer finished with PU coat / Polish of approved shade etc., Complete complying with standard specifications and as directed by the "Engineer-in-charge/Architect".

17

-

-

... More
Supplying and fixing of Booth Seating are as follows. Complete complying with standard specifications and as directed by the "Engineer-in-charge/Architect". Upholstery seating finished with leatherette - 600mm deep & 450mm height

-

-

-

... More
Providing, Fabricating and fixing of upholstery seating of size 600mm deep, 450mm height formed of 50mm x 50mm x 2mm thk aluminium / MS framework & cladded with 19mm thick BWP ply (Both horizontal & vertical surfaces / inclined surface) as per details. Seating top surface to be cladded with 100mm thick high density foam wrapped with leatherette of approved shade & glued to the boxing as per details. all vertical side to be finished with laminate of approved shade. Cost to include Scotchgard for leatherette & upholstery protector from 3M as per architects approval (Profile and Design as per drawings). Rate to include necessary support taken from true floor as per details.

6

-

-

... More
Back rest finished with Fabric - 100mmm thick (Cut to Inclined profile) - 1500mm height

-

-

-

... More
Providing, Fabricating and fixing of back rest formed of 19mm thk ply backing with necessary support as per details. Ply surface to be cladded with 100mm thick high density foam wrapped with leatherette of approved shade & make and to be fixed as per details. Cost to include Scotchgard for leatherette & upholstery protector from 3M as per architects approval (Profile and Design as per drawings). Back rest glued to the boxing as per details.

35

-

-

... More
Ply boxing partitions finished with laminate of approved shade on both sides (Inclined)

-

-

-

... More
Providing, Fabricating and fixing of ply boxing portal formed of 50mm x 50mm x 1.5mm thk concealed aluminium frame vertically and horizontally & frame work to be cladded with 12mm thick ply board on all exposed surface as per details. All exposed ply board surface finished with laminate approved shade & as per details. Rate to include necessary support from true floor as per site conditions. All the surface to be finished with laminate of approved shade as per details.

2

-

-

... More
Centre table of size - 1600mm (L) x 760mm (D) x 750mm (H) - Prelaminated finish

-

-

-

... More
Providing and fixing of centre table top formed of 25mm thick pre laminated ply board with necessary edge banding as per details. Table top support supported with 4 Nos of 50mm dia MS powder coated vertical leg support with powder coated MS base plate as per design as per detail drawings.

2

-

-

... More
Supplying and fixing of Bench Seating are as follows. Complete complying with standard specifications and as directed by the "Engineer-in-charge/Architect". Upholstery seating finished with leatherette - 600mm deep & 450mm height

-

-

-

... More
Providing, Fabricating and fixing of upholstery seating of size 600mm deep, 450mm height formed of 50mm x 50mm x 2mm thk aluminium / MS framework & cladded with 19mm thick BWP ply (Both horizontal & vertical surfaces / inclined surface) as per details. Seating top surface to be cladded with 100mm thick high density foam wrapped with leatherette of approved shade & glued to the boxing as per details. all vertical side to be finished with laminate of approved shade. Cost to include Scotchgard for leatherette & upholstery protector from 3M as per architects approval (Profile and Design as per drawings). Rate to include necessary support taken from true floor as per details.

18

-

-

... More
Lockers: Providing and fixing 4 level storage unit to a width of 450mm and 1880mm height as per drawing but in general, it shall be made out of 9 mm thick HPL board on all sides and intermediate shelves with necessary screws and the openable shutter shall be made out of 9mm thick HPL board with necessary Aluminium Anodised U & F Channels supports etc complete. Rate to include 80mm skirting and all hardware's, auto closing cabinet heavy duty stainless stell hinges, handles - of approved make, including locking arrangements with master key of approved make etc. complete.

7

-

-

... More
Lockers: Providing and fixing 6 level storage unit to a width of 450mm and 1880mm height as per drawing but in general, it shall be made out of 9 mm thick HPL board on all sides and intermediate shelves with necessary screws and the openable shutter shall be made out of 9mm thick HPL board with necessary Aluminium Anodised U & F Channels supports etc complete. Rate to include 80mm skirting and all hardware's, auto closing cabinet heavy duty stainless stell hinges, handles - of approved make, including locking arrangements with master key of approved make etc. complete.

2

-

-

... More
Providing and fixing full height open steel slotted angle racks of 450mm deep with powder coated finish. Each shelve to have a load carrying capacity of 50 kgs. The angles shall be of 60 x 40mmx 3mm thick. Rate to include for providing necessary rack panels of 18 gauge in CRC, screws, hardware, face plates, corner brackets, interconnection for stability with PVC bush., etc.,The cupboard shall be finished with approved shade powder coating of thickness minimum 40 microns etc., Complete complying with standard specifications and as directed by the "Engineer-in-charge/Architect".

2

-

-

... More
Providing and fixing janitory closet for janitorial Services with 3m height etc., Complete complying with standard specifications and as directed by the "Engineer-in-charge/Architect".

1

-

-

... More
Providing and fixing of Cafe Designer Table of 850mm height & 450mm depth. Table top made of 25mm ply finsihed with approved Laminate as per detail drawing. Table top support supported with 25mm thick ply finished with approved laminate on both side vertical leg support as per design. Rate to include provision for placing the artificial tree at the centre etc., Complete complying with standard specifications and as directed by the "Engineer-in-charge/Architect".

1

-

-

... More
ELECTRICAL WORKS

-

-

-

... More
SUPPLY & INSTALLATION OF LUMINAIRES

-

-

-

... More
Supply, Installation, Testing & Commissioning of LED Recessed Full Glow (2X2) Luminaire with a nominal system lumen output of 3600 Lumens (130Lm/W) and a Luminaire Wattage should not exceed 28W with Electronic driver. Also Operating voltage of 140-270V with cut off and auto restart feature @325V. Power factor should be 0.95 & THD should be 10% & CRI80. Color temperature – 5700K. LED Life should be 50,000Hrs. The luminaire housing should be made of powder coated metallic CRCA with high efficiency PS diffuserwith 0-10V Analog dimmable driver . "Dimension :Length = 595 mm , Width = 595mm, Height= 45mm .The supply of accessories like clamps, supporting brackets and hardwares as required and interconnecting with 3 core 1.5 sqmm PVC insulated FRLS copper wire with all accessories required as per site conditions similier to Philips Model No : RC380B LED36S -5700 G5 L60 W60 PSU OD of approved brand as directed by the PMC

35

-

-

... More
Supply, Installation, Testing & Commissioning of LED Recessed Downlighter with a nominal system lumen output of 1500 lumens (110Lm/W) and Luminaire wattage should not exceed 13.5W Also Safe operating voltage 140-270V AC. Power factor should be 0.95 & THD should be 10% & CRI80. Color temperature – 5700K. LED Life should be 50,000Hrs with 2.5KV Surge Protection. Dimension: ø = 140 mm Cutout ø = 110 mm , H=38mm. And its should be Pressuer Die-Cas Al.Housing with PC Diffuser.The supply of accessories like clamps, supporting brackets and hardwares as required and interconnecting with 3 core 1.5 sqmm PVC insulated FRLS copper wire with all accessories required as per site conditions similier to Philips Model No : DN295B LED15S-5700 PSU WHof approved brand as directed by the PMC.

60

-

-

... More
Supply, Installation, Testing and Commisioining of surface mounted 20W Linear LED Fittings with all accessories and fixing the same in the ceiling with wooden blocks, screws ,hardwaresas required as per the site conditions) TWIN GLOW of approved brand as directed by the PMC.

50

-

-

... More
Supply, Installation, Testing & Commissioning of LED COB Type Surface/Suspended Downlighter with a nominal system lumen output of 1500 lumens (1100Lm/W) and Luminaire wattage should not exceed 15W Also Safe operating voltage 140-270V AC. Power factor should be 0.95 & THD should be 10% & CRI80. Color temperature – 5700K. SPD Should be 2.5KV Surge Protection. Dia : 80MM Height ; 170MM And its should be Extruded Al.Housing.The supply of accessories like clamps, supporting brackets and hardwares as required and interconnecting with 3 core 1.5 sqmm PVC insulated FRLS copper wire with all accessories required as per site conditions similier to Philips Model No : SP320P LED15S 5700 PSU DIA80 WHas directed by the PMC.

210

-

-

... More
Supply, Installation, Testing and Commisioining of Wall mount 18W LED Fittings with all accessories and fixing the same in the ceiling with wooden blocks, screws ,hardwaresas required as per the site conditions) CAT: 581880 of approved brand as directed by the PMC.

9

-

-

... More
Supply, Installation, Testing & Commissioning of LED Suspended Continous LED Linear Light with a nominal system lumen output of 4400 lumens (100Lm/W) and The Technical Parameter should be as below CRI 80, THD 10, SDCM5, IP20, Wattage: 44W, Color Temerature : 5700k. SPD should be provided with 4KV, Luminaire wattage should not exceed 20W Dimension: L = 2260 mm Width = 50 mm , mm. And its should be EXTRUEDED AL Housing with PS Diffuser. The supply of accessories like clamps, supporting brackets and hardwares as required and interconnecting with 3 core 1.5 sqmm PVC insulated FRLS copper wire with all accessories required as per site conditions similer to Philips Model No : SP780X LED44-5700 PSU W5L226 OD WH-8FT of approved brand as directed by the departmental officers

80

-

-

... More
Supply, Installation, Testing & Commissioning of LED Suspended Continous LED Linear Light with a nominal system lumen output of 2200 lumens (100Lm/W) and The Technical Parameter should be as below CRI 80, THD 10, SDCM5, IP20, Wattage: 22W, Color Temerature : 5700k SPD should be provided with 4KV, Luminaire wattage should not exceed 20W Dimension: L = 1130 mm Width = 50 mm , mm. And its should be EXTRUEDED Al Housing with PS Diffuser.The supply of accessories like clamps, supporting brackets and hardwares as required and interconnecting with 3 core 1.5 sqmm PVC insulated FRLS copper wire with all accessories required as per site conditions similier to Philips Model No : SP780X LED22S-5700 PSU W5L113 OD WH-4FTof approved brand as directed by the departmental officers

70

-

-

... More
Supplying, erecting, connecting and commissioning of 1 x 5watts per Mtrs cove LED light fitting of with necessary standard accessories also. ( 5mtrs strips with ballast)The supply of accessories like clamps, supporting brackets and hardwares as required and interconnecting with 3 core 1.5 sqmm PVC insulated FRLS copper wire with all accessories required as per site conditions similier to Philips Model NO ; SkyCove LED Stripas directed by the departmental officers

60

-

-

... More
Supplying, erecting, connecting and commissioning of LED light fitting of with necessary standard accessories Continuous Profile based lighting using Extruded aluminium deep profile of 17mm width with frosted diffuser. 24V LED short pitch strip light having power of 12W and 1200lm per metre to be used inside profile neatly pasted using high quality self-adhesive tape of 3M. 24V non integral driver to be used for the LED strip light. The profile and LED Strip should be cuttable as per site requirements. also. ( 5mtrs strips with ballast)The supply of accessories like clamps, supporting brackets and hardwares as required and interconnecting with 3 core 1.5 sqmm PVC insulated FRLS copper wire with all accessories required as per site conditionsof approved brand as directed by the departmental officers

60

-

-

... More
Supply, Installation, Testing and Commisioining of 10W LED miror light with all accessories and fixing the same with wooden blocks, screws ,hardwaresas required as per the site conditions) of approved brand as directed by the departmental officers

25

-

-

... More
Supply, Installation, Testing and Commisioining of 18w decorative suspaned fittings. The supply of accessories like clamps, supporting brackets and hardwares as required and interconnecting with 3 core 1.5 sqmm PVC insulated FRLS copper wire with all accessories required as per site conditions of approved brand as directed by the departmental officer

35

-

-

... More
WIRING FOR LUMINAIRES

-

-

-

... More
DB TO Switch Box

-

-

-

... More
Supply, Laying, Testing and Commisiosning of 2R 2.5S.mm 1R 1.5S.mm PVC insulated FRLS multistrand copper wire in Fully comclead PVC Rigid conduit pipe heavy duty with ISI mark with all accessories as required as per site conditions.of approved brand as directed by the departmental officers

2300

-

-

... More
MAIN LIGHT WIRING (PP)

-

-

-

... More
Supply, Laying, Testing and Commisiosning of 3R 1.5S.mm PVC insulated FRLS multistrand copper wire in Fully comclead PVC Rigid conduit pipe heavy duty with ISI mark ,Modular 5A one way switch with moulded front plate GI anodised enclosure and other associated accessories as required as per the site conditions. of approved brand as directed by the departmental officers

245

-

-

... More
SECONDARY LIGHT WIRING (SP)

-

-

-

... More
Supply, Laying, Testing and Commisiosning of 3R 1.5Sqmm PVC insulated FRLS multistrand copper wire in Fully comclead PVC Rigid conduit pipe heavy duty with ISI mark with all accessories as required as per site conditions.of approved brand as directed by the departmental officers

420

-

-

... More
Supply, Laying, Testing and Commisiosning of 2R 2.5Sqmm + 1R 1.5Sq.mm PVC insulated FRLS Grey colour multistrand copper wire with 25mm dia Fully comclead PVC Rigid conduit pipe heavy duty with ISI mark with all accessories as required as per site conditions.(EL lighting circuit ) of approved brand as directed by the departmental officers

1100

-

-

... More
POWER OUTLETS (SOCKETS)

-

-

-

... More
Supply, Fixing, Testing and Commisiosning of 3 nos 6A 3/5 pin shurtred Universal Type socket and 1 no 16A switch with moulded front plate GI anodised enclosure and other associated accessories in the work station as required as per the site conditions.(for UPS POWER) as directed by the departmental officers and the brand should be got approval.

165

-

-

... More
Supply, Fixing, Testing and Commisiosning of 2 nos 6A 3/5 pin shurtred Universal Type socket and 2 no 6A switch with moulded front plate GI anodised enclosure and other associated accessories in the work station as required as per the site conditions.(for ups POWER) as directed by the departmental officers and the brand should be got approval.

35

-

-

... More
Supply, Fixing, Testing and Commisiosning of 1 no 6A switched socket with moulded front plate GI anodised enclosure and other associated accessories as per the site conditions. as directed by the departmental officers and the brand should be got approval.

20

-

-

... More
Supply, Fixing, Testing and Commisiosning of 1 no 16/6A switched socket with moulded front plate GI anodised enclosure and other associated accessories including chasing embedding rough plastering as required as per the site conditions. as directed by the departmental officers and the brand should be got approval.

110

-

-

... More
Supply, Fixing, Testing and Commisiosning of 1 no 16/6A switched socket with moulded front plate GI anodised enclosure and other associated accessories including chasing embedding rough plastering as required as per the site conditions. (with indicator) as directed by the departmental officers and the brand should be got approval.

32

-

-

... More
Supply, Fixing, Testing and Commissioning of 1 no 6A switched socket with moulded front plate GI anodized enclosure and other associated accessories as per the site conditions.(for UPS POWER) as directed by the departmental officers and the brand should be got approval.

20

-

-

... More
Supply, Fixing, Testing and Commissioning of 1 no 16/6A switched socket with moulded front plate GI anodized enclosure and other associated accessories as per the site conditions. as directed by the departmental officers and the brand should be got approval.

15

-

-

... More
Supply, Fixing, Testing and Commisiosning of 100A TPN RCCB 100mA enclosed in weather proof MS Enclosure with and other associated accessories as required as per the site conditions as directed by the departmental officers and the brand should be got approval.

3

-

-

... More
Supply, Fixing, Testing and Commisiosning of 63A TPN RCCB 100mA enclosed in weather proof MS Enclosure with and other associated accessories as required as per the site conditions as directed by the departmental officers and the brand should be got approval.

4

-

-

... More
Supply, Fixing, Testing and Commisiosning of 63A TPN MCB enclosed in weather proof MS Enclosure with and other associated accessories as required as per the site conditions with star delta stater as directed by the departmental officers and the brand should be got approval.

-

-

-

... More
Supply, Fixing, Testing and Commisiosning of 100A TPN MCCB enclosed in weather proof MS Enclosure with and other associated accessories as required as per the site conditions as directed by the departmental officers and the brand should be got approval.

4

-

-

... More
Supply, Fixing, Testing and Commissioning of 40A DP MCB enclosed in Enclosure with and other associated accessories as required as per the site conditions. as directed by the departmental officers and the brand should be got approval.

4

-

-

... More
Supply, Fixing, Testing and Commissioning of 40A TPN MCB enclosed in Enclosure with and other associated accessories as required as per the site conditions. as directed by the departmental officers and the brand should be got approval.

2

-

-

... More
Supply, Fixing, Testing and Commissioning of 63A TPN MCB enclosed in Enclosure with and other associated accessories as required as per the site conditions. as directed by the departmental officers and the brand should be got approval.

4

-

-

... More
Supply, Fixing, Testing and Commissioning of 32A, 3 pin industrial type interlocked switched socket outlet with 32A DP mcb also 3c,4sqmm cu.cable of 6meter to be provided with termination and is supporting accessories and surface mounting box of IP 44 degree of protection with plug top and other associated accessories as required as per the site conditions. To be fixed in Ceiling trays or in the floor near server/hub rack as directed by the departmental officers and the brand should be got approval.

6

-

-

... More
Supply, Fixing, Testing and Commissioning of 3KVA 1 phase UPS - 230 volt ,50 hz, AC input and output 230 volt AC ,50 hz,sine wave ; 90mins. full load Back-up with maintenance free battery with stand and other associated accessories as required as per the site conditions. (Make : Numeric, DB power & Flipper Clipper) as directed by the departmental officers and the brand should be got approval.

1

-

-

... More
Supply, Fixing, Testing and Commisiosning of 32A DP MCB enclosed in weather proof MS Enclosure with and other associated accessories as required as per the site conditions (Master Control MCB) as directed by the departmental officers and the brand should be got approval.

20

-

-

... More
WIRING FOR POWER

-

-

-

... More
MAIN POWER WIRING (PP)

-

-

-

... More
Supply, Laying, Testing and Commisiosning of 2R 4Sqmm + 1R 2.5S.mm PVC insulated FRLS multistrand copper wire PVC conduit with all accessories as required as per site conditions. as directed by the departmental officers and the brand should be got approval.

60

-

-

... More
SECONDARY POWER WIRING (SP)

-

-

-

... More
Supply, Laying, Testing and Commisiosning of 2R 2.5Sqmm + 1R 1.5S.mm PVC insulated FRLS multistrand copper wire PVC conduit with all accessories as required as per site conditions. as directed by the departmental officers and the brand should be got approval.

120

-

-

... More
CEILING FAN

-

-

-

... More
Supply and installations of 230V, 50HZ, 1200mm blade length, with other necessories , Chasing, embeding, Plastring required as oer site conditions. Note: including suspend rod and regulator as directed by the departmental officers and the brand should be got approval.

6

-

-

... More
Supply, installation, testing and commissioning of exhaust fan up to 300mm sweep in existing opening including making holes / suit the size of the above fan, fixing necessary bolts and nuts making good the damages with required length of 3 core PVC insulated copper wire etc. as required. as directed by the departmental officers and the brand should be got approval.

12

-

-

... More
Supply, Laying, Testing and Commisiosning of 2R 2.5Sqmm + 1R 1.5S.mm PVC insulated FRLS multistrand copper wire in existing PVC conduit with all accessories as required as per site conditions. as directed by the departmental officers and the brand should be got approval.

600

-

-

... More
SECONDARY DISTRIBUTION SYSTEMS

-

-

-

... More
Supply, Installation, Testing and Commisioining of three phase, phase segregated, compartmentalised 8 way MCBDB Double door type, IP 42 powder coated comprising of "C" curve MCB's for LIGHTING DB. as directed by the departmental officers and the brand should be got approval. Incommer - 63A TPN MCB - 1 No Phase Incommer - 63A 30mA DP ELCB/RCCB - 3Nos Outgoings - 6A SP MCB - 24 Nos Blank Plates - 0 Including all interconnections and other associated fixing accessories etc as reqd as per the site conditions.

2

-

-

... More
Supply, Installation, Testing and Commisioining of three phase, phase segregated, compartmentalised 4 way MCBDB Double door type, IP 42 powder coated comprising of "C" curve MCB's for LIGHTING DB. as directed by the departmental officers and the brand should be got approval. Incommer - 63A TPN MCB - 1 No Phase Incommer - 63A 30mA DP ELCB/RCCB - 3Nos Outgoings- 6A SP MCB - 12 Nos Blank Plates - 0 Including all interconnections and other associated fixing accessories etc as reqd as per the site conditions.

1

-

-

... More
Supply, Installation, Testing and Commisioining of three phase, phase segregated, compartmentalised 8 way MCBDB Double door type, IP 42 powder coated comprising of "C" curve MCB's for POWER DB. as directed by the departmental officers and the brand should be got approval. Incommer - 63A TPN MCB - 1 No Phase Incommer - 63A 100mA DP ELCB/RCCB - 3Nos Outgoings - 16A SP MCB - 24 Nos Blank Plates - 0 Including all interconnections and other associated fixing accessories etc as reqd as per the site conditions.

2

-

-

... More
Supply, Installation, Testing and Commisioining of three phase, phase segregated, compartmentalised 8 way MCBDB Double door type, IP 42 powder coated comprising of "C" curve MCB's for POWER DB. as directed by the departmental officers and the brand should be got approval. Incommer - 63A TPN MCB - 1 No Phase Incommer - 63A 100mA DP ELCB/RCCB - 3Nos Outgoings - 16A SP MCB - 12 Nos Blank Plates - 0 Including all interconnections and other associated fixing accessories etc as reqd as per the site conditions.

2

-

-

... More
Supply, Installation, Testing and Commisioining of single phase, 12 way MCBDB Double door type, SPN DB IP 42 powder coated comprising of "C" curve MCB's for EMERGENCY LDB. as directed by the departmental officers and the brand should be got approval. Incommer - 25A DP ELCB - 1 No Outgoings - 6A SP MCB - 10 Nos Blank Plates - 0 Including all interconnections and other associated fixing accessories etc as reqd as per the site conditions.

3

-

-

... More
Supply, Installation, Testing and Commisioining of three phase, phase segregated, compartmentalised 8way MCBDB Double door type, IP 42 powder coated comprising of "D" curve MCB's for UPS DB. as directed by the departmental officers and the brand should be got approval. Incommer - 63A TP+2N MCB - 1 No Phase Incommer - 63A DP MCB - 3Nos Outgoings - 6/16A SP MCB - 24 Nos Blank Plates - 0 Including all interconnections and other associated fixing accessories etc as reqd as per the site conditions.

1

-

-

... More
Supply, Installation, Testing and Commisioining of three phase, phase segregated, compartmentalised 8way MCBDB Double door type, IP 42 powder coated comprising of "D" curve MCB's for UPS DB. as directed by the departmental officers and the brand should be got approval. Incommer - 63A TP+2N MCB - 1 No Phase Incommer - 63A DP MCB - 3Nos Outgoings - 6/16A SP MCB - 12Nos Blank Plates - 0 Including all interconnections and other associated fixing accessories etc as reqd as per the site conditions.

4

-

-

... More
Supply, Installation, Testing and Commissioning of three phase, IP 43 powder coated comprising of KITCHEN DB as directed by the departmental officers and the brand should be got approval. Incommer - 63A TPN MCCB - 1 No Outgoings - 63A TPN RCBO 100mA RCBO - 4 Nos Outgoings - 32A DP RCBO 100mA RCBO - 12Nos Including all interconnections and other associated fixing accessories etc as reqd as per the site conditions.

1

-

-

... More
Supply, Installation, Testing and Commisioining of Three phase, 8way TPN MCBDB Double door type, IP 42 powder coated comprising of "D" curve MCB's for COMMON VTPN DB as directed by the departmental officers and the brand should be got approval. Incommer - 100A TPN MCCB - 1 No Outgoings - 63A TP MCB - 3Nos & 40A DP MCB - 4Nos ,16/20A SP MCB - 12Nos Blank Plates - 0 Including all interconnections and other associated fixing accessories etc as reqd as per the site conditions.

1

-

-

... More
Supply, Installation, Testing and Commisioining of Three phase, 8way TPN MCBDB Double door type, IP 42 powder coated comprising of "D" curve MCB's for LIFT DB as directed by the departmental officers and the brand should be got approval. Incommer: 63A TPN MCB - 1 No Outgoings - 63A TP MCB - 2Nos & 40A DP MCB - 2Nos, 16/20A SP MCB - 6Nos Blank Plates - 0 Including all interconnections and other associated fixing accessories etc as reqd as per the site conditions.

1

-

-

... More
PRIMARY DISTRIBUTION SYSTEM (Note: All the breakers should be Ics = 100% Icu and with pad lock arraangement for handles) CTs shall be with dual ratio and cast resin type only All doors to have rubber gasket with shutter assembly & door seating frame. All MCCBs of 250A and above for non-ups loads will be microprocessor based only and for UPS panels shall be with thermal releases. Note: a) The required Floor Stands & other accessories to mount the panel to be considered in Costing]

-

-

-

... More
POWER PANEL

-

-

-

... More
Supply, Erection, Testing and Commissioning of Indoor type Floor Power panel floor mounting type, dust and vermin proof by construction of 14 SWG CRCA sheets Compartmentalised,all MCCB shall have inbuilt shunt trip coil arrangement and All MCCBs of 250A and above for non-ups loads will be microprocessor based , CTs shall be with dual ratio and cast resin type only.with modular type IP 42 Protection with powder coated panel as specification below Incomer: 2Nos -250A 4P 36kA MOT MCCB 2Set of Current transformer rated 250/5A, 10VA/CI 1.0 for metering. 2 No – Dual source MFM Meter - Cl1 accuracy with LED Display with RS485 port 2 Set – LED type RYB indication lamps with control fuses, In coming breakers shall have LED 'ON / OFF / TRIP' 2 Set - ELR with CBCT. (500mA S) 2 No of TVSS 36kA connected to the Bus Bar. buscupler:-1Nos -250A 4P 36kA MOT MCCB with electrical interlocking arrangement Ref SLD for interlocking scheme Outgoing: 3 Nos - 125A TPN MCCB 12Nos - 63A TPN MCCB 250A Aluminium Bus Bar and Associated Accessories as required. Incoming and outgoing cables shall be of Top entry only.

1

-

-

... More
UPS O/P PANEL

-

-

-

... More
Supply, Erection, Testing and Commissioning of Indoor type UPS OUTGOING PANEL, Floor/Wall mounting type, dust and vermin proof by construction of 14 SWG CRCA sheets Compartmentalised, cable entry shall be in both top and bottom,All MCCBs of 250A and above for non-ups loads will be microprocessor based only and for UPS panels shall be with thermal releases. , CTs shall be with dual ratio and cast resin type only.with modular type IP 42 Protection with powder coated panel as specification below and it CT should connected in common main bus.All MCB should be 'D' curve. Incomer: 1Nos -100A TP+2N MCCB (Neutral should be 200% of the Phase Current) 1Sets of Current transformer rated 100/5A, 10VA/CI 1.0 for metering at common bus. 1Nos – MFM Meter - Cl1 accuracy with LED Display with RS485 port 1Sets – LED type RYB indication lamps with control fuses,In coming breakers shall have LED 'ON / OFF / TRIP' Outgoing: 5 Nos - 63A TP+2N MCCB 100A TP+2N Copper Bus Bar and Associated Accessories as required. (Neutral should be 200% of the Phase Current) Incoming and outgoing cables shall be of Top& Bottom entry.

1

-

-

... More
UPS O/P PANEL SERVER

-

-

-

... More
Supply, Erection, Testing and Commissioning of Indoor type UPS OUTGOING PANEL, Floor/Wall mounting type, dust and vermin proof by construction of 14 SWG CRCA sheets Compartmentalised, cable entry shall be in both top and bottom,All MCCBs of 250A and above for non-ups loads will be microprocessor based only and for UPS panels shall be with thermal releases. , CTs shall be with dual ratio and cast resin type only.with modular type IP 42 Protection with powder coated panel as specification below and it CT should connected in common main bus.All MCB should be 'D' curve. Incomer: 1Nos -100A TP+2N MCCB (Neutral should be 200% of the Phase Current) 1Sets of Current transformer rated 100/5A, 10VA/CI 1.0 for metering at common bus. 1Nos – MFM Meter - Cl1 accuracy with LED Display with RS485 port 1Sets – LED type RYB indication lamps with control fuses, In coming breakers shall have LED ‘ON / OFF / TRIP' Outgoing: 5 Nos - 63A TP+2N MCCB 100A TP+2N Copper Bus Bar and Associated Accessories as required. (Neutral should be 200% of the Phase Current) Incoming and outgoing cables shall be of Top& Bottom entry.

1

-

-

... More
LIGHTING PANEL

-

-

-

... More
Supply, Erection, Testing and Commissioning of Indoor type Floor Power panel floor mounting type, dust and vermin proof by construction of 14 SWG CRCA sheets Compartmentalised,all MCCB shall have inbuilt shunt trip coil arrangement and All MCCBs of 250A and above for non-ups loads will be microprocessor based , CTs shall be with dual ratio and cast resin type only.with modular type IP 42 Protection with powder coated panel as specification below Incomer: 1Nos -63A TPN MCCB 1Set of Current transformer rated 63/5A, 10VA/CI 1.0 for metering. 1Nos – MFM Meter - Cl1 accuracy with LED Display with RS485 port 1Set – LED type RYB indication lamps with control fuses, In coming breakers shall have LED ‘ON / OFF / TRIP' Outgoing: 7Nos - 40A TPN MCB (double door type) 63A Aluminium Bus Bar and Associated Accessories as required.

1

-

-

... More
POWER CABLES AND CABLE TERMINATION

-

-

-

... More
Supply, Laying, Testing and Commisioining of 1100V PVC insulated XLPE and sheathed Armoured/Unarmoured Copper / Aluminium Conductor cables laid over MS supports / Cable racks /fixing of walls including clamping the cable to the support in all approved manner as all complete required. End cable termination lugs shall be as per the respected cable size with respected gland and also double compression gland shall be provide for the 25Sqmm above cable size with double gland earthing to be considered and other accessories to be provided as required as per the site condition. as directed by the departmental officers and the brand should be got approval.

-

-

-

... More
Aluminium Armoured cable XLPE

-

-

-

... More
3.5C 300 sq.mm XLPE AR AL Cable

-

-

-

... More
And it terminaions

-

-

-

... More
3.5C 185 sq.mm XLPE AR AL Cable

150

-

-

... More
And it terminaions

4

-

-

... More
3.5C 150 sq.mm XLPE AR AL Cable

-

-

-

... More
And it terminaions

-

-

-

... More
3.5C 50 sq.mm XLPE AR AL Cable

25

-

-

... More
And it terminaions

2

-

-

... More
3.5C 35 sq.mm XLPE AR AL Cable

-

-

-

... More
And it terminaions

-

-

-

... More
4C 25 sq.mm XLPE AR AL Cable

225

-

-

... More
And it terminaions

12

-

-

... More
4C 16 sq.mm XLPE AR AL Cable

600

-

-

... More
And it terminaions

16

-

-

... More
4C 10 sq.mm XLPE AR AL Cable

150

-

-

... More
And it terminaions

10

-

-

... More
Copper Armoured cable

-

-

-

... More
4C 16 sq.mm Ar. Copper Cable YFY

100

-

-

... More
And it terminaions

6

-

-

... More
4C 10 sq.mm Ar. Copper Cable YFY

50

-

-

... More
And it terminaions

4

-

-

... More
3C 10 sq.mm Ar. Copper Cable YFY

45

-

-

... More
And it terminaions

2

-

-

... More
3C6 sq.mm Ar. Copper Cable YFY

80

-

-

... More
And it terminaions

6

-

-

... More
Copper Unarmoured cable (UPS SYSTEM and EARTHING)

-

-

-

... More
1C 25 sq.mm Copper Cable YY

360

-

-

... More
And it terminations

20

-

-

... More
1C 16 sq.mm Copper Cable YY

560

-

-

... More
And it terminations

40

-

-

... More
1C 10 sq.mm Copper Cable YY

360

-

-

... More
And it terminations

20

-

-

... More
1C 6 sq.mm Copper Cable YY

200

-

-

... More
And it terminations

6

-

-

... More
1C 4 sq.mm Copper Cable YY

180

-

-

... More
And it terminations

12

-

-

... More
CEILING CABLE MANAGEMENT SYSTEM

-

-

-

... More
Supply and Installation of GI Ladder cable trays arch welded including tees,right angle bends,etc., including all fixing accessories etc., of the following sizes as required as per the site conditions.as directed by the departmental officers and the brand should be got approval.

-

-

-

... More
i) 150X50mm Cable Tray

70

-

-

... More
ii) 450X50mm Cable Tray

85

-

-

... More
ii) 600X50mm Cable Tray

-

-

-

... More
Supply and Installation of GI Perforated cable Tray including tees,right angle bends,etc., including all fixing accessories etc., of the following sizes as required as per the site conditions.as directed by the departmental officers and the brand should be got approval.

-

-

-

... More
i) 150X100mm Cable Tray

90

-

-

... More
ii) 300X100mm Cable Tray

25

-

-

... More
EARTHING

-

-

-

... More
Designing, S I T & C of earth station as per IS 3043, with proper earth lead connection arrangements. Rate shall include all materials excavation, refilling, compacting providing 2' dia/ 450 x 450mm 9" thick brick masonry, GI funnel, salt and char coal, hinged cover thick brick masonry, GI funnel, salt and char coal, hinged cover fabricated out of angle iron frame and 7mm thick chequered plate etc., complete. The GI funnel and tapping connection shall not be greater than 10" from the finished floor level.as directed by the departmental officers and the brand should be got approval.

-

-

-

... More
With 600 x 600 x 3mm Copper plate electrode

4

-

-

... More
With 100mm dia 3M long CI Pipe electrode

4

-

-

... More
Chemical Earthing Copper Coated: T-39 Cu. (80mm dia) - 3 mtrs with Back Fill Compund (25 kgs per Bag) includes Providing of RCC Chamber and Civil finishing including painting.

6

-

-

... More
Chemical Earthing Copper Coated: T-39 Cu. (40mm dia) - 3 mtrs with Back Fill Compund (25 kgs per Bag) includes Providing of RCC Chamber and Civil finishing including painting.

-

-

-

... More
EARTH FLAT BUS

-

-

-

... More
Supply & Laying of 50x6mm GI. Flat

250

-

-

... More
Supply & Laying of 50x6mm CU. Flat

-

-

-

... More
Supply & Laying of 25x6mm CU. Flat

-

-

-

... More
Supply & Laying of 25x3mm GI. Flat

200

-

-

... More
Supply & Laying of 25x6mm GI. Flat

100

-

-

... More
Supply & Laying of 10 SWG bare Cu. Wire

200

-

-

... More
Supply and Installation of 12 way 25x3mm copper earth bus with all accessories as required.

2

-

-

... More
UPS & BATTERY

-

-

-

... More
10KVA DOUBLE CONVERSON UPS with Internal isolation transformer, two input sources with IGBT, anti harmonic filters of THD 3%.(all the technical datas of the system to be enclosed with the offer). The UPS shall be supplied with remote monitoring panel with necessary power/communication cables and accessories as required. ( Server ups) as directed by the departmental officers and the brand should be got approval.

1

-

-

... More
Sealed Maintenance free batteries for30 minutes battery backup at full load for the above UPS with battery cubicle, isolator and associated accessories as directed by the departmental officers and the brand should be got approval.

1

-

-

... More
15KVA DOUBLE CONVERSON UPS with Internal isolation transformer, two input sources with IGBT, anti harmonic filters of THD 3%.(all the technical datas of the system to be enclosed with the offer). The UPS shall be supplied with remote monitoring panel with necessary power/communication cables and accessories as required. (office-2 ups) as directed by the departmental officers and the brand should be got approval.

1

-

-

... More
Sealed Maintenance free batteries for 20 minutes battery backup at full load for the above UPS with battery cubicle, isolator and associated accessories as directed by the departmental officers and the brand should be got approval.

1

-

-

... More
Supply of 3 Phase Modular UPS connected in N+1 configuration with IGBT rectifier & IGBT Inverter along with below items. The UPS systems should be with SNMP card & BMS compatibility,SMS provisoion , 2x20 KVA modular UPS with next size Frame . (office-1 ups) as directed by the departmental officers and the brand should be got approval.

1

-

-

... More
SAFETY EQUIPMENTS

-

-

-

... More
1100V Rubber mat as per latest IS

3

-

-

... More
First Aid Box

1

-

-

... More
First Aid Chart (English & Local language)

1

-

-

... More
ASSOCIATED ACCESSORIES

-

-

-

... More
Supply and fixing of 2mm thick PVC/MS conduit of various dia., exposed or concealed, with all accessories and fish wire.as directed by the departmental officers and the brand should be got approval.

-

-

-

... More
Supply and Fixing of 20mm PVC Conduits

540

-

-

... More
Supply and Fixing of 25mm PVC Conduits

960

-

-

... More
Supply and Fixing of 20mm MS Conduits

75

-

-

... More
Supply and Fixing of 25mm MS Conduits

-

-

-

... More
Supply and Installation of M.S. Material for ladder type cable trays, cable supports, SB, DB's supports, iron embeded in the wall, steel structure in open Area painted with two coats of primer and two coats of enamel paint. and as directed by the departmental officers and the brand should be got approval.

300

-

-

... More
Supply and arranging for Temporary Power Supply for lighting and other contract agencies at site incliding sufficiant no of tube light fittings, sifficiant no. of plug points with plug tops with adequate distribution boards and all other necessory safety devices like elcb, etc., to ensure safe and continued supply at site. up to end of the project. as directed by the departmental officers and the brand should be got approval.

1

-

-

... More
SHOP DRAWINGS, INSPECTION AND APPROVALS

-

-

-

... More
Preparation of Shop drawings as per site conditions based the GFC drawings, the same shall be approved by client / consultant / architects. Obtaining approval from Statutory Authorities, Preparation of statutory drawings, completion Report, Arranging for Inspection, attending defects report and obtaining safety certificate from Safety Authorities for commissioning of the electrical systemand as directed by the departmental officers and the brand should be got approval..(including all required statutory Norms ). Five sets as built drawings with soft copy shall be submitted.

1

-

-

... More
PHE WORKS

-

-

-

... More
PART-A SANITARY FIXTURES & CP FITTINGS

-

-

-

... More
Supplying and fixing in position White / Colour Special Delux Model Glazed Cascade Type Parryware / Hindware / Equivalent Wall Mounted European Water Closet of best quality and approved make with 100mm “P” or “S” trap connecting with CI pipe of 100mm dia / PVC pipe of 110mm dia, double flapped rigid PVC black seat and seat cover with CP brass hinges including cost of white cement, cement for packing, spun yarn, teak wood plugs, brass screws, etc., including supplying and fixing 10 litres capacity PVC / 12.5 litres capacity porcelin low level flushing tank with a pair of CI brackets, etc., complete with all fittings, such as, 15mm brass ball valve with polythene float with brass handle, union coupling connected by means of 40mm white PVC flush hand using indian adopter joint including all internal fittings, such as, 15mm bras connections, 15mm GM wheel valve, 15mm brass nipple (2 Nos.), 15mm nylon connection, TW plugs, screws and also giving necessary connection to the PVC pipe and painting the CI brackets with 2 coats of approved paint over one coat of red oxide primer, dismantling the masonry and re-doing the dismantled masonry to original condition, etc., complete complying with standard specifications. (The EWC and flushing tank with all accessories should be got approved by the Executive Engineer before use on works) with 10 litres capacity flushing tank with all internal dual flush fittings with normal seat cover Wall Fitting. Supply, Installing, testing and commissioning of Wash Hand Basin of size 550mm x 400mm with all accessories such as Cast Iron Brackets, 32mm dia CP Waste Coupling, Rubber Plug and Chain, 32mm dia 'B' Class GI Waste Pipe, 15mm dia GM Wheel Valve, 15mm dia Nylon Connection, 15mm dia Brass Nipples, 15mm CP Pillar Tap etcWhite without Pedastal & grab bar. (For handicapped toilet) or equalant ( Rate including all material , labour charges and transportation charges etc all ) - Quantitative Reliability Optimization (QRO)

3

-

-

... More
Supplying and fixing in position White / Colour Special Delux Model Glazed Cascade Type Parryware / Hindware / Equivalent Wall Mounted European Water Closet of best quality and approved make with 100mm “P” or “S” trap connecting with CI pipe of 100mm dia / PVC pipe of 110mm dia, double flapped rigid PVC black seat and seat cover with CP brass hinges including cost of white cement, cement for packing, spun yarn, teak wood plugs, brass screws, etc., including supplying and fixing 10 litres capacity PVC / 12.5 litres capacity porcelin low level flushing tank with a pair of CI brackets, etc., complete with all fittings, such as, 15mm brass ball valve with polythene float with brass handle, union coupling connected by means of 40mm white PVC flush hand using indian adopter joint including all internal fittings, such as, 15mm bras connections, 15mm GM wheel valve, 15mm brass nipple (2 Nos.), 15mm nylon connection, TW plugs, screws and also giving necessary connection to the PVC pipe and painting the CI brackets with 2 coats of approved paint over one coat of red oxide primer, dismantling the masonry and re-doing the dismantled masonry to original condition, etc., complete complying with standard specifications. (The EWC and flushing tank with all accessories should be got approved by the Executive Engineer before use on works) with 10 litres capacity flushing tank with all internal dual flush fittings with normal seat cover Wall Fitting or equalant ( Rate including all material , labour charges and transportation charges etc all ). Supply ,Installing, testing and commissioning of EWC WM WITH SEAT COVER "ENZO NEO +" - Model no: Q167240310

5

-

-

... More
Supply ,Installing, testing and commissioning of Concealed Cistern Sisma with half frame & accessories. - Model no: Q507450310

5

-

-

... More
Supply ,Installing, testing and commissioning of flush plate Sisma Rectangolo - Model no: Q507455320

5

-

-

... More
Supplying and fixing in position Indian Water Closet (Oriya type) of size 580 x 440 mm colour glazed earthern ware of approved quality and brand with "P" or "S" trap conforming to BIS with sand cushion and forming flooring alround the closet using 40mm broken brick jelly in lime concrete 1:2:5 (One lime, Two sand and Five brick jelly) 100mm thick and finishing the top to the required slope and including giving necessary connection to PVC pipes (including the cost of 110mm dia PVC pipe for a length of 600mm) by dismantling brick masonry wall/ reinforced cement concrete roof / floor slab and making good the dismantled portion to the original condition with leakages etc., complete complying with standard specifications and as directed by the departmental officers.( The water closet should be got approved by the Executive Engineer before use on works).

5

-

-

... More
Supply, Installing, testing and commissioning of Wash Hand Basin with all accessories such as Cast Iron Brackets, 32mm dia CP Waste Coupling, Rubber Plug and Chain, 32mm dia 'B' Class GI Waste Pipe, 15mm dia GM Wheel Valve,15mm dia Nylon Connection, 15mm dia Brass Nipples,15mm CP Pillar Tap etc White without Pedastal. Under Counter Basin size: 53x34x17 cm - Model no: Q197150110

5

-

-

... More
Supply ,Installing, testing and commissioning of Square Bottle Trap "ACCESSOREIS" - Model no: Q503191720

5

-

-

... More
Supply ,Installing, testing and commissioning of Pop up waste full cap - Model no: Q503191520

5

-

-

... More
Supply ,Installing, testing and commissioning of SS Waste Coupling 32mm Full Thread - Model no: F860010CP

5

-

-

... More
Supply ,Installing, testing and commissioning ofAngle Valve -Model no: Q503191120

5

-

-

... More
Supply ,Installing, testing and commissioning of Pillar Cock "BRYN" -Model no: Q193112120

5

-

-

... More
Supply, Installing, testing and commissioning of CP Health Faucet with CP Two Way Bib Cock - Health Faucet - Model no: Q503192520

5

-

-

... More
Supplying and fixing in position PVC cowls of following dia of best approved quality conforming to BIS, etc., complete complying with standard specifications. (The PVC cowl should be got approved by the Executive Engineer before use on works).

-

-

-

... More
110mm dia - Quote Rate Only (QRO)

50

-

-

... More
75mm dia -Quote Rate Only (QRO)

50

-

-

... More
Supply, installation and fixing of stainless steel toilet paper holder 150 x 150mm with aluminium roller.( Sample should be got approved )

5

-

-

... More
Supply, Storing and fixing of ABS body Liquid soap dispenser with SS screws on the wall.( Sample should be got approved )

6

-

-

... More
Supply, Storing and fixing of Stainless steel body paper towel dispenser with SS screws on the wall.( Sample should be got approved )

5

-

-

... More
Supply, installation and fixing of Robe hook with PVC rawl plug & C.P. brass screw complete as required.( Sample should be got approved )

5

-

-

... More
Supply, Installing, testing and commissioning of stainless steel sink size 600 mm x450mmx200mm, with 15m dia CP swivel spout , 32mm dia CP waste coupling, 32mm dia CP bottle trap with extension pipe, supporting CI bracket to support sink, and CP wall flanges, and testing for leakages etc., (The sink & specials should be got approved by the exclusive engineer before use on works)

1

-

-

... More
Supplying, Installing, testing and commissioning of shower set including exposed wall mixer, spout and over head showers -Shower arm 220mm - Model no:Q503152220 or equalant, Shower Head - AQUAPLAY SQUARE SHOWER 200- Model no:Q503141120 or equalant , Shower Mixer -Concealed Bath&Shower Mixer Body "ASTER"- Model no:Q503158420 or equalant , Shower Mixer Plate -Concealed B&S Mixer Plate,Handle&Tip Ton - Model no:Q113123720 or equalant, Bath Spout-Bib cock with Wall Flange "ASTER"- Model no:Q113113120 or equalant - Quantitative Reliability Optimization (QRO)

1

-

-

... More
Supply, iinstallation and fixing testing and commissioning of apparoved make electically operated storage water heater inner container made from copper or stainless steel including the remal instalation safety valve, vacuum relief valve, neon lamp, mounting brackets, angle valve, connection hose installing in position with coach screws or bolts, nuts, testing, commissioning, etc, complete. Make / Model : jaquar / Erica vertical

-

-

-

... More
a) 10 ltrs (For STARTUP TN PANTRY)

1

-

-

... More
b) 25 ltrs - Quantitative Reliability Optimization (QRO)

1

-

-

... More
Supplying, installing, fixing, jointing, testing and commissioning of Stainless steel type Water cooler (Capacity 25 LPH), Outlet of Hot, Cold, Warm. (Location - STARTUP CAFÉ) Make : Voltas / Blue star

1

-

-

... More
PART-B INTERNAL SOIL AND WASTE WATER SYSTEM

-

-

-

... More
Supplying, fixing and testing of approved make of 10kg PVC pipes confirming to IS 4985-2000. and fittings (moulded and fabriacted fittings ) such as tee, elbow, 'y' , coupler, etc confirming to IS 7834 with latest amendment for soil and waste pipe works in toilets etc. Pipes shall be laid in under floors/ under ceiling / sunken floor as per approved drawings. For laying the pipes in walls, before chasing, the pipe line routing shall be marked using chalk line with help of tube level,Pipes and fittings shall be cleaned with pipe cleaners and joined by approved approved make solvent cement. After laying the pipes, before closing the pipes, gravity test to be conducted and got the approval from the engineers in charge

-

-

-

... More
40mm dia

55

-

-

... More
50mm dia

16.5

-

-

... More
Supply and fixing , Testing and Commissioning of PVC pipes Type-B confirming to IS- 13492 soil,waste & rainwater pipes jointed with solvent cement of good quality lubricant inclusive of all necessary specials like bends, tees, offsets, junctions, pan connector, cowls etc., laid under floor / under ceiling / on walls with suitable clamps including making bores in masonry etc., and rendering the bores in cement mortar after laying the pipes and specials curing etc., complete. The quoted rate should include necessary supports like hanger supports, grip bolts and clamps etc.,. Fixing of universal clamp for hanging pipeline is done at no extra cost and is included in the cost of installation of piping.(Brand & Specifications as per Design )

-

-

-

... More
75mm dia

93.5

-

-

... More
110mm dia

88

-

-

... More
Providing & fixing in position deep seal multiway PVC floor Trap with cockroach trap and PVC extension piece of required length depth of following size to suit site conditions and multiple inlets, to suit site conditions with inlet sizes ranging from 40 mm to 75 mm. The bottom of the sump shall be dummied water tight. Wherever, sumps are shown to have water seal, the seal depth shall be minimum 40 mm. The sump shall be laid in cement concrete bed with 1:2:5 mix with 40 mm brick jelly bed all around and finished with cement mortar 1:3. Providing and fixing heavy class C.P. brass mosquito proof grating with frame of approved design including setting in floor with cement mortar to match with floor finish. ( Sample should be got approved )

11

-

-

... More
Supply, fixing and testing of PVC Floor cleanout (150x150mm) . For removing Clogging, etc., complete.(The frame and grating shall be approved by Architects)

6

-

-

... More
Supply, fixing and testing of Ceiling cleanout. For removing Clogging, etc., complete.(The frame and grating shall be approved by Architects)

-

-

-

... More
110 mm Dia - Quote Rate Only (QRO)

10

-

-

... More
75 mm Dia - Quote Rate Only (QRO)

10

-

-

... More
Supply and fixing of cockroach trap grating , complete as per specifications. (The item rate shall include all costs towards labour, tools, tackles & machineries, all leads & lifts, work related cleaning) complete. Square Drain Jali (5x5) "Angular"- Model No:F860058SS or equalant

17

-

-

... More
PART-C INTERNAL WATER SUPPLY

-

-

-

... More
Supply, installation and testing of CPVC pipes and fittings SDR-11 (upto 50mm dia) & SCH 80(above 50mm dia) conforming to ASTM D 2846. CPVC fusion compound shall conform tro ASTM F493. The scope of including, cutting, cleaning and fixing in/on walls under ceiling, on terrace, etc.,. The quoted rate shall include for making necessary chasing, making bores in foundation, walls, slabs, etc., and making good the chased surfaces and bores in cement mortar. Fixing of universal clamp for hanging pipeline is done at no extra cost and is included in the cost of installation of piping.(Internal Concealed,above ceiling piping , Shaft & terrace) (DWS, HWS & RO)as directed by the depatmental officers

-

-

-

... More
20mm Dia

198

-

-

... More
Supplying and fixing in position first quality and approved variety of Gun metal gate valve / wheel valve with BIS make of the following dia including cost of shellac, thread balls, etc., complete complying with standard specifications ( for both internal and external water supply arrangements). the valves to be used on work shall be got approved by the executive engineer before use on work.

-

-

-

... More
20mm Dia

13

-

-

... More
25mm Dia - Quantitative Reliability Optimization (QRO)

1

-

-

... More
HVAC WORKS

-

-

-

... More
AIR CONDITIONING WORKS

-

-

-

... More
Supply, Installation, Testing & Commissioning & Handing over of the following:

-

-

-

... More
DOUBLE SKIN PLENUM for AHU's

-

-

-

... More
All Sheet metal cabinet type double skin air plenum section for air handling units supplied by Developer.The plenum shall be constructed using double-skinned acoustic panels with minimum 0.6 mm thick pre-coated GSS sheet for outer skin and & minimum 0.6 mm plain GSS sheet for inner skin of the unit. All the panels shall incorporate 50 mm thick PUF insulation sandwiched in between inner & outer skin.

-

-

-

... More
Double skin Plenum with all supports suiting to site conditions. Plenum colour shall be similar to the existing AHU.

90

-

-

... More
OUTDOOR MOUNT TYPE EXHAUST FAN' S

-

-

-

... More
800 Cfm - 15 mm external static double skin Inline fan with all necessary supports. (Pantry exhaust). Fan shall be provided with in built fan regulator.

1

-

-

... More
1000 Cfm - 25 mm external static double skin Inline fan with all necessary supports. (Toilet exhaust). Fan shall be provided with in built fan regulator.

1

-

-

... More
400 Cfm - 15 mm external static single skin Inline fan with all necessary supports. (Battery room exhaust).

1

-

-

... More
Supply fixing testing & commissioning of Hyderagen sensor with sequential timer suitable control panel to operate Battery room exhaust fan at regular 2hrs interval fan run 5.0 minutes and when increse the Hyderagen level above 1% switch ON the fan. Controller shall have bypass mode to switch ON / OFF manually with necessary control wiring.

1

-

-

... More
Supply and installation of wall mount type Propoeller fan with gravity damper for below capacity

-

-

-

... More
150CFM propeller fan

3

-

-

... More
200CFM propeller fan

-

-

-

... More
Note: All Exhaust air units should be compatible of third party BMS system integration & fire trippig should be consider in part AC vendor scope. HVAC vendor should be coordinate with Electrical & BMS vendor.

-

-

-

... More
Sheet Metal Work using with Ductmate(TDF) Flanges for all sizes of the duct. Fabrication as per SMACNA Standards. Galvanizing shall be Class VIII – light coating of zinc, nominal 120 gm / sqm surface area and Lock Forming Quality prime material alongwith mill test certificates. In addition, if deemed necessary, samples of raw material, selected at random by owner’s site representative shall be subject to approval and tested for thickness and zinc coating at contractor’s expense. All ducts shall be fabricated and installed in workmanlike manner, conforming to relevant SMACNA codes. All duct construction and installation shall be in accordance with SMACNA standards. In addition ducts shall be factory fabricated utilizing the following machines to provide the requisite quality of ducts. Above 1000mm width duct bends Vanes to be considered every 300mm once cost inclusive of this items.The Duct shall be supported with specified Supports at regular intervalas as mentioned in the technical specifications. (To ensure the air tightness, (All ducts shall be checked with third party Pressure test after completion of installation but before applying insulation) Report should be submit. Ducts to be sent in Factory fabricated. The factory fabricated ducts shall be of pre-approved make only. The quoted costs should include: i) Ducts with reinforcement/ strengthening, ii) Air tight joints, iii) Accessories such as splitter, damper, guide vane etc., iv) Hangers and supports shall be as per Technical specification., v) Painting with Black color paint for duct sides behind the grills. vi) The gasket used in case for all ducts shall be fire retardant type, vii) Ducts shall be fully sealed with Silicon Sealant for leak tight installation. Ducts shall be leak tested & leakages should be within acceptable limits. Note: Supplier air duct should be dust free before switch ON the AHU otherwise vendor should do Robotic cleaning without additional cost.

-

-

-

... More
Rectangular ducting: Sheet Metal Ducting As per Specification. Pressure 500 Pa

-

-

-

... More
26 G Ducting with TDF flanges(0-550mm)

700

-

-

... More
24 G Ducting with TDF flanges(551-900mm)

350

-

-

... More
22 G Ducting with TDF flanges(901-1200mm)

280

-

-

... More
20 G Ducting with TDF flanges(1201-1600mm)

150

-

-

... More
18 G Ducting with TDF flanges(1601 & above)

50

-

-

... More
Supply & applying of spray painting for exposed rectangular ducts(colour to confirmed by PMC/ARCH) -2 coats of primer to be considered as first level. Further based on finalized color one set of painting to be done. And final coat to be applied. Supply and install GI sheet metal Flat oval Spiral ducting with (factory made internal thermal insulation -9 mm thick closed cell material to be considered cost of this shall be inclusive of this item) fittings, Gripple supports, The factor of gripple to suit to duct weight, with necessary anchor fasteners and hook arrangements with suitable rod thickness,etc., confirming SMACNA standards. Duct should be fabricated by using CNC machines, Including necessary civil works as per site condition. including spray painting for exposed ducts to match interior. Colour shall be confirmed by Architect. (factory made internal thermal insulation -9 mm thick closed cell material to be considered cost of this shall be inclusive of this item) The supports etc. shall be painted with 2 coats of red oxide and 2 coats of enamel paint of approved color. The Ducts shall be painted at site as per approved color / shade. The painting shall be limited to roller paint & shall attain good & even finish. Painting of ducts to be in interior agency scope. HVAC Vendor to co-ordinate for the same. Provided wire support for open ceiling ducts area same shall be inclusive of elliptical ducting costing Make: Hilti/3M

-

-

-

... More
24 G ( With Ductmate Flanges)

150

-

-

... More
22 G ( With Ductmate Flanges)

80

-

-

... More
20 G (With Ductmate Flanges)

60

-

-

... More
18 G (With Ductmate Flanges)

20

-

-

... More
Air Terminal Devices

-

-

-

... More
Powder coated, extruded aluminium, removable center core type, square tegular type diffusers of aluminium construction of the following neck sizes. The diffuser shall be mounted in the GI box (not in scope), with inlet connector suitable for flexible duct. GI Box & Flexible duct quantified seperately. ( colour to be confirmed by Arch/ PMC team before placing the order) (All are of 600 x 600 MM Outer to Outer Size)

-

-

-

... More
450 x 450 MM (Neck Size)

40

-

-

... More
375 x 375 MM (Neck Size)

20

-

-

... More
300 x 300 MM (Neck Size)

10

-

-

... More
Supply,installation ,testing & comissioning of Swirl diffusers -Outer size 600x600mm,

1

-

-

... More
DRAIN PIPE

-

-

-

... More
Linear Slot Diffusers - to be fixed in techzone ceiling

-

-

-

... More
Adjustable curved slot diffuser with aesthetically shaped face section, suitable for installation in false ceiling system. Comprising face section with 1-4 slots, either with integral or additional slide on flanges, end caps (plates or angles) and with inset air control blades which can be used to provide any direction of air discharge. These blades are factory set but can be site adjusted by others to alter air discharge direction to meet local requirements. Complete with rear mounted plenum box fitted with side entry spigot and four suspension brackets to hang complete assembly from the ceiling. The slot diffuser has a variable neck length and depending on construction, the diffuser face section can be factory fitted to the plenum box or suplied superately for second fix on site. (colour to b confirmed by Arch/ PMC team before placing the order, it will be either broken white / off white / black etc as chosen by atchitect/PMC) . 3- Slot Linear Diffuser (16 mm wide Slot) - 150 mm wide

-

-

-

... More
Slot Diffuser as per specification but without plenum box & End Flanges

20

-

-

... More
End Flanges suitable for above size

6

-

-

... More
Hit & Miss Damper for above size

2

-

-

... More
Circular Diffusers

-

-

-

... More
Powder coated, extruded aluminium, removable center core type, supply / return air diffusers without volume control dampers of aluminium construction of the following neck sizes. The diffuser shall be mounted in the GI box (not in scope), with inlet connector suitable for flexible duct. GI Box & Flexible duct quantified seperately. Measurement shall be based on outer to outer size of the air terminal device ( colour for the grill to b confirmed by Arch/ PMC team before placing the order)

-

-

-

... More
250mm dia

10

-

-

... More
Powder Coated grilles for supply and return distribution ( colour for the grill to b confirmed by Arch/ PMC team before placing the order) . Deflection of the grille shall be 0 / 15 / 30. same will be confirmed later. Single / 2 way / 4 way deflection shall be confirmed later.

12

-

-

... More
Collar Dampers of opposed blade type made out of Aluminium alloy extrusion with anodised matt black finish (quantity including for diffusers & grills)

4

-

-

... More
Powder Coated Curved grilles with collar damper for supply distribution in Oval duct ( colour for the grill to b confirmed by Arch/ PMC team before placing the order) . Deflection of the grille shall be 0 / 15 / 30. same will be confirmed later.

4

-

-

... More
supply & installation of Exhaust Disc Vlaves with spigot damper for Toilet Exhaust system

-

-

-

... More
200 mm dia

-

-

-

... More
160mm dia

-

-

-

... More
125mm dia

-

-

-

... More
Volume Control Dampers made out of 100 x 40 x 1.55 mm thick galavanised steel frame and blades of 1.55 mm galavanised sheet steel. For Rectangular duct.

10

-

-

... More
Motorised On/off type volume Control Dampers made out of 100 x 40 x 1.55 mm thick galavanised steel frame and blades of 1.55 mm galavanised sheet steel

4

-

-

... More
Actuators with control panel, panel should be compatible for third party BMS integration .necessary fire integrator should be consider in part HVA Cvendor scope

6

-

-

... More
Motorized Modulating type low leakage air dampers for fresh air modulation with actuator complete with all accessories like Actuator,control panel etc and any necessary requirement which can perform the controlling the Damper. It shall be integrated with Co2 sensor and based on CO2 levels, damper shall be modulate.

2

-

-

... More
Supply & fixing of CO2 sensor for above fresh air same should be integrate with BMS system.

3

-

-

... More
ACTUATORS with control panel should be compatible for third party BMS integration .necessary fire integrator should be consider in part HVACvendor scope

3

-

-

... More
Insulated Flexible Ducting

-

-

-

... More
Factory Fabricated Insulated Flexible made out aluminium for connecting from main duct to diffuser box. The length of the flexible duct shall be around 1.0 to 1.5 mtr

-

-

-

... More
The flexible duct shall me made of double lamination of aluminium foil, polyester and metalised polyester film permanently bonded to a coated spring steel wire helix. The exterior shal be wrapped with 25mm thick 16 kg / cum fibreglass insulation. The outer insulation jacket / vapour barrier made of fibreglass reinforced metalised polyester film laminate.

-

-

-

... More
200 mm dia

10

-

-

... More
250 mm dia

60

-

-

... More
300 mm dia

15

-

-

... More
Butterfly Dampers-22 Guage

-

-

-

... More
200 mm dia

5

-

-

... More
250 mm dia

50

-

-

... More
300 mm dia

10

-

-

... More
Rigid round ducts fabricated out of 22 G sheets to be used as extention pieces at the diffuser boxes.

-

-

-

... More
250mm dia

30

-

-

... More
300mm dia

5

-

-

... More
SPILL AIR BOXES

-

-

-

... More
Supply,installation,testing & comissioning of 600 x 600 x 450 mm High and 250mm dia Sheet Metal Spill air boxes made out of 26 GI sheet for connecting the diffuser outlet & flexible connection from the main duct.(10 mm internal acoustic insullation to be provided) cost inclusive of the item

60

-

-

... More
Supply,installation,testing & comissioning of 1200 x 150 x 450 mm High Sheet Metal Spill air boxes made out of 26 GI sheet for connecting the diffuser outlet & flexible connection from the main duct.(10 mm internal acoustic insullation to be provided) cost inclusive of the item

10

-

-

... More
Supply,installation,testing & comissioning of 1000 x 150 x 450 mm High Sheet Metal Spill air boxes made out of 26 GI sheet for connecting the diffuser outlet & flexible connection from the main duct.(10 mm internal acoustic insullation to be provided) cost inclusive of the item

10

-

-

... More
Supply and installation of Acrylic fire stop sealant CP606 or Approved Equivalent )with minimum 2 hours fire rating when tested in accordance with UL 1479 standards, shall be used along the periphery of ducts & chiller pipes without insulation passing through fire rated walls and floors made of concrete, masonry, metal, gypsum construction to provide up to 2 hours insulation and integrity when subject to the test conditions of UL 1479 standards. The product shall also be age tested as per DafStb guidelines. Sealant to provide sufficient MAF, water and gas tight seal apart from providing an airborne sound transmission reduction (STC of 50) and shall be tested as per DIN 52210 for sound insulation . The product should be tested for mold resistance rating of 0 as determined by ASTM G21-96 and should have a VOC content of approx. 75 g/l as per LEED 2009. The sealant shall be FM approved. All installations to be in full accordance with the manufacturer. The sealant should be tested in accordance with IEC 60068-2-57:1999-11 (Environmental Testing) as per Part 2-57: Test for Vibration-Time-history method and VERTEQII for seismic zone 4. The product shall bear the UL and FM approval logo on the packing where applicable. The rate shall include the mineral wool backing material and other miscellaneous items etc.., Assumed 15% Penetrants Ocupancy. Firestop installation should be done by HAFSC ( Accredated Firestop Speciality Contractor by providing complete installation report using CFS DM). Or using FIT (Firestop Installer Training) Program. As per IFC Guideliness EJ is recomended for non standard openings.-( supply & return air ducts.)

8

-

-

... More
Fire dampers UL 555 S listed & certified for AHU supply & return air ducts.16 Guage -frame & 16 Guage Blade to be considered.Interlocking of fire dampers using copper control wiring and requisite relays with existing AHU starter panel shall be affected as required. The dampers shall be BMS compatible as per the specifications. UL 555S Leakage Rating Leakage Class: I or II, Damper shall be Multi-blade type damper with 2.0 hours fire rating

8

-

-

... More
Actuators for above fire dampers- HIGH TORQUE TYPE-10/15 NM suitable of damper tourqe.

10

-

-

... More
Actuators for critical room fire dampers- MEDIUM TORQUE TYPE 5/7 NM suitable of damper tourqe.

4

-

-

... More
Fire damper control panel with Modbus over RS485 output for BMS compatibility. Each panel shall be located in PAC room and shall control 4-6 fire dampers. It should take one fire input and from the FD panel we need to provide output to trip the AHU & APU. (If the fire damper panel is off then AHU & APU should not turn ON). - This shall be BMS compatible with Modbus over RS485 output

4

-

-

... More
Fire damper control panel with Modbus over RS485 output for BMS compatibility. Each panel shall be located in PAC room and shall control 8-12 fire dampers. It should take one fire input and from the FD panel we need to provide output to trip the AHU & APU. (If the fire damper panel is off then AHU & APU should not turn ON). - This shall be BMS compatible with Modbus over RS485 output

2

-

-

... More
Supply, installation, testing and commissioning of Fusible link type Fire Damper of 90 minutes fire resistant complete with all standard accessories. Fire damper as per UL 555-S, outer shell constructed with 1.6mm thick galvanized steel frame and the blade/Leaf with 1.6mm thick GSS in accordance with the GFC/ shop drawings

-

-

-

... More
CABLES and END TERMINATIONS.

-

-

-

... More
Supply, laying, testing & commissioning of MS insulated MS sheathed, steel armoured ,aluminium conductors 1100 V grade power cables. The cables shall be laid in tray built up trench etc., Rate shall exclude the cost of tray

-

-

-

... More
3 runs of 2.5 sq.mm HFLS Cu Wire in 19 mm dia MS Conduit for damper panel to Fire dampers

200

-

-

... More
3 runs of 2.5 sq.mm HFLS Cu Wire in 19 mm dia MS Conduit for AHU panel to Fire damper

50

-

-

... More
Back draft damper for all room dual units/source-18 Guage

-

-

-

... More
Supply Fabrication , and erection of Double canvas connection made out of fire retardent canvas cloth with Zip required necessary fixing arrangements including nuts & bolts Etc

10

-

-

... More
DUCT INSULATION MATERIALS

-

-

-

... More
Supply and installation of (Accoustic) Duct liner (Insulation) of specified thickness of Elastromeric Rubber Insulation manafactured as per ASTM E 84 test & which should also meet NFPA 90A supplementary materials for air distribution system which should not absorbs less 0.2% water by volume (ASTM c 209), should not support microbial growth (ASTM C1071, G21, G22) and should emit objectionable odors (ASTM C 665) and should have thermal conductivity of 0.27 ( R - 2.78 in 3.4" thickness) and water vapor permeance of 0.10. - Class "1" Material-.All joints of the Insulation material should be further covered with 50 mm wide 3 mm thick self adhesive tape made of similar material & Black Cotton Tape shall not be used. with manufacturer recommended adhesive inline with LEED requirement.

-

-

-

... More
10 mm thick- Qunatity included for Cross talk attenuators also

120

-

-

... More
15 mm thick

-

-

-

... More
Supply and installation Thermal (Insulation) of specified thickness of Elastomeric Rubber Insulation manufactured as per ASTM E 84 test & which should also meet NFPA 90A supplementary materials for air distribution system which should not absorbs less 0.2% water by volume (ASTM c 209), should not support microbial growth (ASTM C1071, G21, G22) and should emit objectionable odors (ASTM C 665) and should have thermal conductivity of 0.27 ( R - 2.78 in 3.4" thickness) and water vapor permeance of 0.10. Joints should be sealed with 100 mm wide 3mm thick self adhesive tape (Black Cotton Tape not acceptable). Class "O" Material-Material should be FM approved. For internal ducts ,insulation should be provided without any patches. For duct insulation, surface should be dust free .One coat adhesive to be provide on surface & material should be provided. All joints of the Insulation material should be further covered with 50 mm wide 3 mm thick self adhesive tape made of similar material & Black Cotton Tape shall not be used. with manufacturer recommended adhesive inline with LEED requirement.

-

-

-

... More
9 mm thick

1400

-

-

... More
13 mm thick

-

-

-

... More
AHU room acoustic insulation with 25 mm thk. open cell Class 1 nitrile rubber insulation density of 140-180 kg/m3 with 22G GI grid work in 1.2 x 0.6 mt. Insulation shall be applied AHU room walls after completing all works and cleaning the AHU room walls properly. Contractor shall ensure insulation is cut properly and applied properly minimising the joints. with manufacturer recommended adhesive inline with LEED requirement.

150

-

-

... More
Sound Attenuators (for supply and return air ducts), Sound attenuator qty shall be measured on cross section and not on the surface area

-

-

-

... More
COMPUTER SELECTION SHOULD BE ATTACHED

-

-

-

... More
Sound Attenuators of dissipative type to be provided on the supply & Return air duct entering the AHU Room. Sound Attenuators shall consist of outer casing, sound absorbing material and internal baffles, splitters and supports as expalined in the technical specifications. Casing shall be of galavanised steel of not less than 20G in thickness. Casings shall be tested to 150mmwg and shall show no leakage or distortion in this condition. Sound absorbing material shall be high density fibre glass held in place with at least 5% compression to prevent voids due to settling. Absorption material density shall be minimum 48 kg/cum. Fibreglass faced with minimum 26 g perforated galvanised sheet metal of minimum 40% open area. Combustion ratings shall be as expalined in the tender specifications

-

-

-

... More
Supply,Installation & commissioning

8

-

-

... More
Acoustic Louvers (Z Pieces) - to be installed for all rooms & closed cabins

-

-

-

... More
Supply and installation of RA intake with acoustic duct Z pieces of 450 / 600 / 900 mm length to suit site requirements & as shown on the approved drawing complete with: a) Sheet steel enclosure, b) Acoustic Z piece duct (inside of duct sheets with both sides lining & a centre baffle sheet also lined on both sides with 10 mm thk Armasound Nitrile acoustic insulation- with Thermal conductivity 0.045 W/m deg.K / density 140~180 kg/m3, with manufacturer recommended adhesive 520 bonding., c) Z piece sample to be approved at site beforehand.

80

-

-

... More
Under deck Insulation of specified 19mm thickness of Elastromeric rubber insulation of Class "O" manafactured as per ASTM E 84 test & which should also meet NFPA 90A supplementary materials for air distribution system which should not absorbs less 0.2% water by volume (ASTM c 209), should not support microbial growth (ASTM C1071, G21, G22) and should emit objectionable odors (ASTM C 665) and should have thermal conductivity of 0.27 ( R - 2.78 in 3.4" thickness) and water vapor permeance of 0.10. Joints should be sealed with 50 mm wide 3 mm thick self adhesive tape (Black Cotton Tape not acceptable). Server/Lab Room

-

-

-

... More
Insulated Condensate Drain Piping

-

-

-

... More
Supply Insulated PVC Condensate Drain piping as per specification as mentioned in the document insulated same as chilled water piping but without polyshield covering.Consider drip pans with drian pipe .Entire draine pipe needs to be insulated with Nitrile rubber.

-

-

-

... More
50 mm dia

-

-

-

... More
40 mm dia

-

-

-

... More
32mm dia

-

-

-

... More
25 mm dia

-

-

-

... More
19 mm dia

-

-

-

... More
SEQUENTIAL CONTROL PANNEL

-

-

-

... More
Supply ,installation testing and commissioning of auto change over Sequential control panel and necessary Auxillary contactors with suitable relay for SWITCH OFF the Builder Ahu automaticall SWITCH ON the ductable unit and close the supply & return air actuator from ahu duct and open the CSU supply & return air motorized damper, and Controller Should have compatible for switch ON the stand by unit incase of rise in temperature above the set poit, with necessary, PF contact, thermostate control wiring between thermostate to unit. panel should be suitable of thirparty BMS integration.

2

-

-

... More
Associated Civil Works

-

-

-

... More
Pedestals : Providing & Laying of Reinforced cement concrete of M20 grade at the level given below, using river sand, 20 mm as down size coarse aggregates, application of necessary admixtures as specified by consultants inclding all leads and lifst, scaffolding wheever necessary, curing as directed, including the cost of shuttering, centering and staging for required height.

-

-

-

... More
Chipping, chassing & Plastering the wall openings in cement mortor 1:6 of 15 mm thick finishing to line and level with sand faced finshing at all levels, including all leads & lifts, scaffolding, curing etc complete (for SA & RA openings in ahu rooms, opgs for CHW pipes etc)

10

-

-

... More
AIR BALANCING WORKS

-

-

-

... More
Third party Air balancing as per the approved shop drawing using valid calibrated instruments, including Air Flow HOOD which has capability to measure volumetric flow rate with digital manometer, multi point averaging air flow sensor, airflow measurement station. Documentation ,representation & Carrying on Air balancing using digital HOOD. Cost including of applying Sealent/Tightening of duct joints to reduce the air leakages with necessary tool to be considered.

1

-

-

... More
IAQ TESTING

-

-

-

... More
Indoor Air quality test to be conducted after refurbishment works considering below parameters. Inside Temperature & RH, Air movement velocity, CO2 levels, Suspended Particulate Matter Microgram /M3) (Pm 2.5 & Pm 10), Total VOC content, Formaldehyde, Nitrogen dioxide content, Ammonia content, Sulphur Dioxide content, Oxygen (O2), Bacterial and Fungal count, Hydrogen Sulfide (H2S), Ammonia (NH3), Carbon Monoxide (CO), Ozone (O3)

-

-

-

... More
Total 5 points - 1 points in Board Room, 1 point in We lounge 1 in Meeting room, and 2 in open office area with sampling at each location 4 times during the day

1

-

-

... More
VAV Installation works

-

-

-

... More
Installation of VAV box along with VAV connection duct pipece taper & circular duct, without damages, same to be coordinate with BMS vendor. Note: VAV supplied by BMS vendor

-

-

-

... More
VAV Unit shall be ceiling suspended with hanger brackets & vibration isolators.

-

-

-

... More
Rectangular VAV Unit shall be of the following sizes : Cost shold be quote accordinling as per tender drawing

-

-

-

... More
0-250 CFM

-

-

-

... More
Supply & Installation of VAV boxes

14

-

-

... More
251-500 CFM

-

-

-

... More
Supply & Installation of VAV boxes

9

-

-

... More
501-750 CFM

-

-

-

... More
Supply & Installation of VAV boxes

8

-

-

... More
750-1000Cfm

-

-

-

... More
Supply & Installation of VAV boxes

2

-

-

... More
1001-1250Cfm

-

-

-

... More
Supply & Installation of VAV boxes

2

-

-

... More
1251-1500Cfm

-

-

-

... More
Supply & Installation of VAV boxes

1

-

-

... More
1501-1750Cfm

-

-

-

... More
Supply & Installation of VAV boxes

-

-

-

... More
1751-2000Cfm

-

-

-

... More
Supply & Installation of VAV boxes

-

-

-

... More
2001-2250Cfm

-

-

-

... More
Supply & Installation of VAV boxes

-

-

-

... More
2251-2500Cfm

-

-

-

... More
Supply & Installation of VAV boxes

-

-

-

... More
2501-2750Cfm

-

-

-

... More
Supply & Installation of VAV boxes

2

-

-

... More
2751-3000Cfm

-

-

-

... More
Supply & Installation of VAV boxes

-

-

-

... More
3001-3250Cfm

-

-

-

... More
Supply & Installation of VAV boxes

-

-

-

... More
3251-3500Cfm

-

-

-

... More
Supply & Installation of VAV boxes

-

-

-

... More
3501-3750Cfm

-

-

-

... More
Supply & Installation of VAV boxes

-

-

-

... More
Elliptical VAV Unit shall be of the following sizes : Cost shold be quote accordinling as per tender drawing

-

-

-

... More
0-250 CFM

-

-

-

... More
Supply & Installation of VAV boxes

2

-

-

... More
251-500 CFM

-

-

-

... More
Supply & Installation of VAV boxes

2

-

-

... More
501-750 CFM

-

-

-

... More
Supply & Installation of VAV boxes

6

-

-

... More
750-1000Cfm

-

-

-

... More
Supply & Installation of VAV boxes

4

-

-

... More
1001-1250Cfm

-

-

-

... More
Supply & Installation of VAV boxes

2

-

-

... More
1251-1500Cfm

-

-

-

... More
Supply & Installation of VAV boxes

1

-

-

... More
1501-1750Cfm

-

-

-

... More
Supply & Installation of VAV boxes

-

-

-

... More
1751-2000Cfm

-

-

-

... More
Supply & Installation of VAV boxes

-

-

-

... More
2001-2250Cfm

-

-

-

... More
Supply & Installation of VAV boxes

-

-

-

... More
2251-2500Cfm

-

-

-

... More
Supply & Installation of VAV boxes

1

-

-

... More
2501-2750Cfm

-

-

-

... More
Supply & Installation of VAV boxes

-

-

-

... More
2751-3000Cfm

-

-

-

... More
Supply & Installation of VAV boxes

-

-

-

... More
3001-3250Cfm

-

-

-

... More
Supply & Installation of VAV boxes

-

-

-

... More
3251-3500Cfm

-

-

-

... More
Supply & Installation of VAV boxes

-

-

-

... More
3501-3750Cfm

-

-

-

... More
Supply & Installation of VAV boxes

-

-

-

... More
Note1: VAV quantity will vary if any changes in architectural drawings

-

-

-

... More
2core, 1.5 Sqmm, screened ATC/sheathed cable communication cable in PVC Conduit of 19 mm dia for looping between VAV’S & BMS.

840

-

-

... More
Supply & Fixing of duct pressure sensor in the rang of 0 to 500 Pascal.

-

-

-

... More
NOTE:Looping all VAV's with communication cable & leaving the cable inside BMS room and coordinating with BMS vendor is part of HVAC vendor scope

-

-

-

... More
Supply, laying & Termincation of 2C X 1sq.mm copper sheiled Control cable between VFD and Duct pressure sensor

100

-

-

... More
Supply & fixing of 16G M.S.Conduit for cable laid between VFD and Duct pressure sensor

100

-

-

... More
All necessary Network controller or Router, Interface to connect the proposed floor BACNET MS/TP VAV with the main BMS system via Native BACnet / IP. Network controller or Router - Shall automatic rout BACnet messages between BACnet IP, BACnet Ethernet, BACnet PTP, and BACnet MS/TP ports and sub-lan networks. It shall conformance to ANSI/ASHRAE standard 135-2008 for designated “router” functions. The controller shall support foreign device registration with BACnet Broadcast Management Devices (BBMD). Total no. of network controller shall be based on manufacturer requirement. 1 network controller / router panel shall not exceed integrating / connecting 30 VAV boxes. The Network controller or Router shall be housed in a suitable metal enclosure with proper power protection. Integrator to have necessary convertors for taking into BOS system

2

-

-

... More
VRV/HI BRID AIR-CONDITIONING EQUIPMENTS:(100% INVERTER TYPE ONLY TO BE QUOTED) - R410A refrigerant

-

-

-

... More
Supply & Installation of VRV /VRF airconditioning system comprising of Modular type high efficiency Twin Rotary Multiple Compressor with inverter, High efficiency heat transfer Cooling Coil suitable for Environment friendly R410a refrigerant,Air cooled propeller type condenser fan with DC motor drive,interconnecting piping, suction line insulation etc., Micro-processor control panel suitable for automatic operation,High speed calculation inverter control, active oil control mechanism incorporating all safety functions as per equipment specifications & other points as listed below: The unit mounted starter panel shall be complete with IP-55 protection consisting of power disconnecting switches with fuses, soft starters, for compressor motors, under/over voltage trip, single phase preventers, communication card which can accept 4-20 mA or 2-10 Vdc analog signal. All components shall be mounted on welded steel base frame, structural steel profiles/panels made out of galvanized sheet steel, protected with primary coat & finished with epoxy paint. Modular type outdoor units equipped with highly efficient scroll compressors, with inverter type compressor(s),special acryl precoated heat exchanger,low noise condenser fan,auto check function for connection error, auto address & UNIT Price shall be inclusive of outdoor stand price.Shifting & Installing of ODU as per shop drawing is part VRV vendor scope.(ODU Location & Capacity mentioned below).Shifting of Out door units from GF to fourth floor is part of VRF vendor scope. The Outdoor units shall be complete as per technical specifications. For LEED Submission, please provide EER values at 100% load @ AHRI conditions of 210/240 conditions in the Data sheets for HVAC equipments. The VRF system shall be selected with higher EER requirements as per ANSI/ASHRAE/IESNA Standard 90.1–2010 for VRV systems as per LEED requirements as follows: COP 3.6 and IPLV 4.3. All VRV units should be compatible for third party BMS integration .necessary fire integrator should be consider in part HVAC/VRF vendor scope

-

-

-

... More
Outdoor Unit(ODU) : Cooling Capacity :14 HP side discharge for Critical room ( Ups & Hub room Standby units )

2

-

-

... More
Outdoor Unit(ODU) : Cooling Capacity :10 HP

-

-

-

... More
INDOOR UNITS

-

-

-

... More
Indoor Unit(IDU): Cooling type : All the units should be supplied with Cordless remote control. The following Indoor unit capacities are required for each type of Room.Drycontact should be considered for Auto change over,failure status,overload sequencing etc..

-

-

-

... More
Serving Area: 1.5 TR Hi wall unit

-

-

-

... More
Serving Area: BMS ROOM 2.0 TR Hi wall unit

-

-

-

... More
Serving Area: UPS & BATTERY ROOM 4.1 TR Ductable unit

2

-

-

... More
Serving Area: HUB ROOM 6.6 TR Ductable unit

2

-

-

... More
Serving Area: 8.0 TR Ductable unit

-

-

-

... More
REFRIGERANT PIPING

-

-

-

... More
Interconnecting copper refrigerant pipe work duly insulated with elastomeric nitrile rubber type tubular insulation between indoor & outdoor units as per specifications . All piping inside the room shall be properly supported with hanger and all piping should be run in perforated cably tray.Cable tray qty specified seperately.. MS supports for refrigerant piping & cables, using angles, channels, Tees, flats, etc should be considered as part of scope.All MS supports shall be given a coat of red-oxide primer and two coats of synthetic enamel paint of approved colour.

-

-

-

... More
41.3mm OD (insulation =19 mm thick)

-

-

-

... More
34.3mm OD (insulation =19 mm thick)

-

-

-

... More
28.6mm OD (insulation =19 mm thick)

120

-

-

... More
22.2mm OD (insulation =13 mm thick)

50

-

-

... More
19.1mm OD (insulation =13 mm thick)

20

-

-

... More
15.9mm OD (insulation =13 mm thick)

120

-

-

... More
12.7mm OD (insulation =13 mm thick)

15

-

-

... More
9.5mm OD (insulation =13 mm thick)

20

-

-

... More
6.4mm OD (insulation =13 mm thick)

-

-

-

... More
Insulated Condensate Drain Piping

-

-

-

... More
Supply and Insulated CPVC Condensate Drain piping as per specification. Consider drip pans with drian pipe .Entire draine pipe needs to be insulated with Nitrile rubber.

-

-

-

... More
40 mm dia

20

-

-

... More
32 mm dia

15

-

-

... More
25 mm dia

10

-

-

... More
Electrical Cable between Isolator to ODU.Suitable size copper flexible cable with necessary earthing insulation

10

-

-

... More
Providing & fixing of 2 Cx 1.5 sqmm cu. cable for control cum trans-mission between Indoor unit and Out Door Unit through PVC Conduit.

200

-

-

... More
Note:Cable from Electrical panel to isolator excluded in VRV vendor scope.same should capture in Electrical vendor scope. Cable from Isolator to ODU is part of VRV Vendorscope.

-

-

-

... More
Imported fittings like Y-Joints and headers etc as per the layout( additional supports should consider for both ends of the Y joint)

2

-

-

... More
Supply & providing of MS stand for VRV ODU along with proper supports-suitable for above configuration

2

-

-

... More
Filling, testing, commissioning including topping up of R410 A Refrigerant.

24

-

-

... More
CABLE TRAY

-

-

-

... More
Supply & providing of GI Powder coaded cable tray (perforated type) of for routing copper pipes at terrace level

-

-

-

... More
size:150x 50mm(14 SWG grade)-2mm thick

20

-

-

... More
size:300x 100mm with box tray with cover (14 SWG grade)-2mm thick cover to be provided in the open area

50

-

-

... More
CENTRAL CONTROLLER & REMOTE SYSTEM

-

-

-

... More
Supply & installation,testing & comissioning of Centarl controller integrating all floor Indoor units with necessary software & spare parts

1

-

-

... More
DRAIN PUMP

-

-

-

... More
2 Litre SS storage tank with 2 inbuilt drain pumps (1W+1S). Tank and pumps shall be housed in a tray and supported to wall/ceiling as per site conditions sholud be BMS compactabilit

1

-

-

... More
FIRE EXTINGUISHER , FIRE ALARM SYSTEM AND PUBLIC ADDRESS SYSTEM

-

-

-

... More
Fire Extinguisher System

-

-

-

... More
Supply, installation ,testing & commissioning ofCo2 type Fire Extinguisher of 4.5Kgs. Capacity, made from brand new seamless cylinder, as per IS: 7285 and CCE approval, fitted with hose and horn, supplied complete with initial charge as per IS:15683 specn. with ISI mark alongwith Bracket

24

-

-

... More
ABC Stored Pressure type fire extinguisher of 6Kgs. capacity, supplied complete with initial charge as per IS:15683 specn.with ISI mark along with Bracket, hose and Pressure Guage

21

-

-

... More
Supply, installation ,testing & commissioning of Mechanical Foam Squeeze Grip Cartridge type fire extinguisher of 9Ltrs.capacity, fitted with gunmetal cap, Co2 gas cartridge and hose with nozzle with AFFF Liquid 540ml. and supplied complete with initial charge as per IS:15683 specn. with ISI mark alongwith bracket.

-

-

-

... More
Supply, installation ,testing & commissioning of Co2 type fire extinguisher of 22.5Kg. capacity made from brand new seamless cylinder as per IS:7285 with CCOE approval, fitted with hose and horn, supplied complete with trolley wheels and handle and initial charge as per IS:16018:2012 specn. with ISI mark. including conveyance, all incidental charges,neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the Departmental Officers.

-

-

-

... More
Supply, installation ,testing & commissioning of Fire Bucket with Canopy and Stand- 9 Liters Capacity (4 Buckets/Set). As per IS:2546

-

-

-

... More
Fire Detection & Alarm System

-

-

-

... More
Supply, Installation, Testing & Commissioning of Addressable 2 loop fire alarm control panel expandable up to 4 loop as per the specification, complete with battery backup of 24 hours operation and 30 minutes alarm operation, with inbuilt battery charger and annunciator windows etc. The system shall have potential free contacts' provision to integrate with life safety facilities i.e. HVAC,Fire Hydrant & Sprinkler System, lift or elevator by providing NO/NC contacts, IP based and BMS compatibility shall through MODBUS/ BACnet protocol. Panel shall be compatible for DC controllers & OFC integration with other manufacturer panel with necessary indications.

1

-

-

... More
Supply, Installation, Testing & Commissioning of Analogue Addressable Microprocessor based Active Repeater panel with LCD display complete system function keys for programming and control like system reset, Alarm Acknowledge, Alarm Silence, Trouble Acknowledge etc.

-

-

-

... More
Supply, Installation, Testing & Commissioning of Analogue Addressable Multi criteria detector with compatible mounting bases, Junction box and other accessories, as required and working on 19-24V DC supply, all complete as required.

227

-

-

... More
Response indicator with LED display for all detectors located above false ceiling.

95

-

-

... More
Supply, Installation, Testing & Commissioning of Analogue Addressable Control Relay Module, for tripping the field devices, with LED indication, automatic mapping device, electronic addressing and working at 24V DC and all other accessories, all complete, as required.

8

-

-

... More
Supply, Installation, Testing & Commissioning of Addressable Manual pull station - Break glass / Pull type, having dual pole (action) type combination of tripping contact one for loop and other for access controlled door and an integrally mounted addressable module, that monitors and reports the contact status.

7

-

-

... More
Supply, Installation, Testing & Commissioning of Analogue Addressable Electronic Hooter cum Strobe of 88dba/90dba.

20

-

-

... More
Supply, Installation, Testing & Commissioning of Analogue Addressable Fault isolator module, capable of monitoring shorted loop circuit and automatically restore communications, when shorted conditions are corrected with plug in arrangement, LED status indication and other accessories, all complete as required, working on 19 - 24V DC.

13

-

-

... More
Supply, Installation, Testing & Commissioning of Analogue Addressable Monitor Module, single output type, for monitoring the field devices, with LED status indication, automatic mapping device, electronic addressing and working at 24V DC and all other accessories, all complete, as required. (for fire sprinkler flowswitch, ).

6

-

-

... More
Supply, Installation, Testing & Commissioning of 2C x 1.5 sq.mm 1100 volts grade PVC insulated sheathed FRLS copper conductor armoured cable as per specification.

4850

-

-

... More
Supply, installation, testing & commissioning of MS conduits on ceiling / wall / floor etc. complete with accessories like, junction boxes, collars, bends etc. 25mm Dia.

35

-

-

... More
EPUBLIC ADDRESS SYSTEM

-

-

-

... More
SITC of 6W RMS False Ceiling Mount Speakers with inbuilt 100V Line Matching Transformer, wide opening angle, optimized for music & speech applications with mounting clamps as per specifications

90

-

-

... More
SITC of 6W RMS True Ceiling Mount Speakers with inbuilt 100V Line Matching Transformer, wide opening angle, optimized for music & speech applications with powder coated back box, supports as per specifications Speakers shall have the tappings at 1.5/3/6 watts

50

-

-

... More
SITC of 6 W Wall Mounted box Speakers with line matching transformers as specified as per specifications

7

-

-

... More
SITC of System Controller 6 zone complete with Microprocessor based, Dual Tone Control for Speech & Music,have scheduler/timer for automatic announcement, etc.

1

-

-

... More
SITC of 6 zone call station with microphone with accessories

1

-

-

... More
SITC of Rack Mounted 240 W Power Amplifier

1

-

-

... More
SITC of Rack Mounted 480 W Power Amplifier

2

-

-

... More
2C x 1.5 mm2, Stranded Copper conductor,Type A ST1 PVC insulated,Armoured FRLS Cable 1100 V as per IS 1554, with GI saddle spacers every 0.3 mtr with Single compression Cable Glands,ABS Junction Boxes (wherever required), terminals,Ferruling complete.

3500

-

-

... More
SITC of Volume controller for one speaker (near call station)

1

-

-

... More
Rack Mounted DVD Player as per specifications

1

-

-

... More
SITC OF Suitable size rack as per following specification, Conforms to DIN 41494 Or Equivalent EIA/ISO/EN/CEA Standard Finish - Powder coated finish with Seven tank pretreatment process meeting ASTM standard Color - Black/off white/grey Fan module on top of the rack Welded frame with vented top cover with fan , perforated Metal Door with lock & Key and Back vented / Perforated metal door with lock & key and partially vented side panels, free standing on floor with 4 No. casters wheels with 2 no with brakes & 2 No. without brakes, cable oraginesers, Levelers with required 16A/5A power strips including accessories. Number of racks shall be as per the design requirement. vendor to consider required number of racks as per their requirement

1

-

-

... More
ELV WORKS

-

-

-

... More
CCTV SYSTEM

-

-

-

... More
Supply, Installation, Testing and Commissioning of CCTV System as per specification requirements and as directed by engineer in charge to be completed in all respect of approved make and schematic submitted with tender document.

-

-

-

... More
CCTV Camera: Supply, Installation, Testing & Commissioning of Indoor Bullet Camera 1/3" High Resolution Varifocal Lens IR LED Camera, Built-in 3.6x (2.8 ~ 10mm) varifocal lens with auto iris, Day & Night with ICR (Infrared Cutfilter Removal), Day & Night with ICR (Infrared Cutfilter Removal), Protection against water & dust (IP66), Sunshield with all accessories like tamper proof screws, clamps, wiring etc. complete as required.

1

-

-

... More
Indoor 4MP IP IR Minidome WDR 2.7-12mm, Color Camera, 1/3" CMOS, H.264 High-profile, Triple Stream support, True Day & Night (TDN) with ultra low light, Wide Dynamic Range (WDR), Open Network Video Interface Forum (ONVIF) Profile S & G, TF card support, IP67 & IK10, Power Over Ethernet (POE), 24VAC/12VDC, IR distance upto 20 Meter depending on scene reflectance. Certification UL. Quoted price shall inclusive of camera mounting brackets as per site requirement.

9

-

-

... More
Networking video Recorder (NVR) with 10 TB Hard Disk.

1

-

-

... More
49" LED Monitor with HDMI, Operating station & Control console

1

-

-

... More
 The following port of 10/100/1000 base-T managed standalone Gigabit switch

-

-

-

... More
24 port Gigabit switch with POE(Green Ethernet)

1

-

-

... More
The following size of IT Rack (sheet metal construction) for mounting of Patch Panel, Switch with all mounting accessories etc and suitable on free standing

-

-

-

... More
12U rack

1

-

-

... More
The following sizes of copper conductors cable complete with termination and testing as per requirement.

-

-

-

... More
1 x 4P CAT 6 cable

800

-

-

... More
The following sizes of following length of Patch Chord complete with termination and testing as per requirement.

-

-

-

... More
1 x 4P Cat 6 Patch cord 3 mtrs

9

-

-

... More
ACCESS CONTROL SYSTEM

-

-

-

... More
Supply, Installation, Testing and Commissioning of Access Control System as per specification requirements and as directed by engineer in charge to be completed in all respect of approved make and schematic submitted with tender document.

-

-

-

... More
Supply, Installation, Testing and Commssioining of 2 reader controller, power supply unit, TCP IP connectivity with tamper detection provision as per the tender specifications.Cost shall inclusive of enclosure and power supply unit for controller/EM locks (power supply unit shall inclusive of battery backup 8 hrs). Controller Should Support global Antipass back.

5

-

-

... More
HID Proximity Cards as per the specifications

200

-

-

... More
Biometric with smart Cards Reader as per the specifications

10

-

-

... More
The following type of door(wooden, steel, glass )with frames & including frameless glass doors) with external Door Electro Magnetic Lock

-

-

-

... More
Single door electro Magnetic Lock suitable for (wooden, steel, glass )with frames including frameless glass doors), free contact output and door position sensor

9

-

-

... More
Exit push switch

1

-

-

... More
Emergency break glass for exit push switch

5

-

-

... More
Door Buzzers

5

-

-

... More
Power unit for door lock with transformer and inverter

5

-

-

... More
The following port of 10/100/1000 base-T managed standalone Gigabit switch

-

-

-

... More
24 port Gigabit switch with POE(Green Ethernet)

1

-

-

... More
The following sizes of cable complete with termination and testing as per requirement.

-

-

-

... More
2 core x 2.5 sq. mm, FRLS armoured cable including cable gland, crimping & all Accessories required etc.

500

-

-

... More
RS485 Cable & all Accessories required etc.

900

-

-

... More
1x8c 1.5mm FRLS Armourmed Cable from the Access Control units to the card readers.

1500

-

-

... More
ASS & FES WORKS

-

-

-

... More
FIRE SIGNAGE SYSTEM

-

-

-

... More
" FIRE EXIT " (BATTERY BACKUP TYPE) - SINGLE SIDE - FOR FIRE EXIT DOORS - 150*300mm with suspension chains (SS)

3

-

-

... More
" Emergency Exit Signages - (Autoglow) size 150 x 300mm - double side with suspension chains (SS)

55

-

-

... More
" EXTINGUISHER Signages - Autoglow, with suspension chains (Autoglo signages, size 150 x 300) - double side with suspension chains (SS)

24

-

-

... More
" MCP Signages - Autoglow, with suspension chains (Autoglo signages, size 150 x 300 - double side with suspension chains (SS)

8

-

-

... More
" Hydrant - Autoglow, with suspension chains (Autoglo signages, size 150 x 300 - double side with suspension chains (SS)

3

-

-

... More
Fire Evacuation Route Map as per following specificationPreparation of drawing and providing, Autoglow Fire escape route map in clear acrylic glass and required glass studs supports etc. Indicating direction, Key plan, contact numbers etc. (The sample of the same need to be presented for approval before execution)…. (Maximum size of the board A2) Evacuation plan shall be glow in dark. A2 size with 5mm thick rear & 3mm thick front acrylic cover including wall mount supports.

12

-

-

... More
AUTOMATIC SPRINKLER SYSTEM

-

-

-

... More
Supplying, installing,hydraulic testing and commissioning of Heavy grade G.I Pipes confirming to IS :1239 part - I with malleable specials confirming to IS:3589 part - II, such as Tees, elbows, check nuts, unions, flanges, nipples etc. Including cutting, fixing in / on walls / on Floors, ceiling by using suitable supports such as MS channels ,angles,flats,rods as required at site with anchor fasteners,clamps,threaded rods,nuts,bolts,washers etc...complete. Painting the exposed with one coat of metal zinc chromate primer with two coats of synthetic enamel paint of approved colour / shade etc., complete.The pipe fittings shall be Groveed up to 150 mm dia, Rate shall inclusive of groveed fittings.

-

-

-

... More
150mmdia

108

-

-

... More
100mmdia

132

-

-

... More
80mmdia

72

-

-

... More
65mmdia

66

-

-

... More
50mmdia

96

-

-

... More
40mmdia

120

-

-

... More
32mmdia

84

-

-

... More
25mmdia

456

-

-

... More
Supply, Installing, testing and commissioning of Stainless Steel Corrugated Flexible Braided Pipe (Hose) for dropping sprinklers below false ceiling. Pipe shall be 16 bar pressure rating and 1500mm long, 25mm dia with union / reducer, collar, clamps, etc. It shall have UL listed and FM approved.

250

-

-

... More
Supplying and installing of approved type Rosette Plates (Recessed Type in Two Pieces) for sprinklers below false ceiling area. The Rosette shall be fabricated by MS plate of 2mm thick and the finish shall be powder coated and colour, as directed by the Departmental Officers.

250

-

-

... More
Supply and fixing nominal bore quartized bulb type sprinkler bulb 68 Deg C fast response pendent type including GI collar for each sprinkler bulb, mounted in MS pipe line using suitable size MS threaded coupling, thread, shellac etc., as per standard methods and including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the Departmental Officers. Make: OMEX / KARTAR / LIFE GUARD / SAFE GUARD / EQUIVALENT. .

250

-

-

... More
Supply, erection, testing and commissioning of Gun Metal Gate Valve of size 50mm dia size including necessary MS flange of table ‘E’, gaskets, bolts & nuts etc., installed at pump house delivery line for the purpose of priming water to suction line including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the Departmental Officers. Make: LEADER / QUIVALENT.

1

-

-

... More
Supply, erection, testing and commissioning of Pressure Gauge with 0 to 14 kg. range of reputed make with necessary valve, milling thread MS coupling fixed at delivery pipe line in pump house to read the developing pressure including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the Departmental Officers. Make: H GURU / ISI MAKE / EQUIVALENT.

1

-

-

... More
Supply, Installation, Testing & Commissioning of Flow Switches with two NO and two NC contacts with necessary nipple & other fittings, Flow switch shall be suitable for 150 dia

1

-

-

... More
Supplying, Installing, testing and commissioning Cast Iron Butterfly Valve Wafer Type Lever Operated PN-1.6 Wwith Integrally moulded liner of nitrle or Epdm,S.S (CF-8) DISC, S.S STEM

1

-

-

... More
Supply testing and commissioning of 15 mm gunmetal/chrome quartzoid bulb, standard response sprinkler heads suitable for 68 deg. C, K 80 Upright Bulb

300

-

-

... More
Testing & commissioning of sprinkler system 24hr at 12 bar pressure for the entire network

1

-

-

... More
MODULAR FURNITURE

-

-

-

... More
WORKSTATION : ECO SYSTEM

-

-

-

... More
LINEAR WORKSTATION SIZE : 1200X600X1050MM HT

-

-

-

... More
TABLE TOP : Table top is made of 25mm thick Pre.Lam particle board with 2mm PVC Edge banding supported on Mild steel Powder coated legs MAIN - 4+4 GLASS SANDWICH PRIVACY PANEL Not Considered items : Pedestal, CPU,KBT. Glass - 4+4mm Sandwich glass with rounded corners Radius 10mm for safety, Mounted on Aluminium diecast Brackets of 40 x 60mmHt with powder coated finish. IO LEGS: Made of Mild Steel 1.6 mm thickness powder coated with 60 microns round tube inclined leg (300mm HT SS-304 grade adjustable legs) with ‘SS’ leveler. CENTER T LEG : MS 50X50 Square leg with CRCA Pipe of 1.6mm thickness of 60 microns Powder coated leg for Table top Stability. MS CONNECTOR: 50X25mm Square CRCA Pipe of 1.6mm thickness of 60microns Powder coated connector for Table top support. HORIZONTAL RACEWAYS Made of 1mm Thick mild steel Sheet Powder coated to 60 Microns, Horizontal raceways face plate cutting 75mm deep & 120mm ht provided below the table top for electrical, Date wire management & Socket fixing. FLIP UP BOX : Flip up are made in aluminum extrusion with Anodized finish. And it’s also provided with Single opening access. SIZE : 400X145MM METAL PERFORATED MODESTY PANEL - MAIN & END TO END CONSIDERED. Made of 1mm thick Mild steel sheet with 60microns Powder coated Modesty panel provided below the table top privacy, Main & End to End.

102

-

-

... More
WORKSTATION : PLAN SYSTEM

-

-

-

... More
CORNER WORKSTATION: SIZE:1500/1500X600X1200MM HT TABLE TOP : Table top is made of 25mm thick Pre.Lam particle board with 2mm PVC Edge banding supported on Mild steel Powder coated legs MAIN - 4+4 GLASS SANDWICH PRIVACY PANEL Glass - 4+4mm Sandwich glass with rounded corners Radius 10mm for safety, Mounted on Aluminium diecast Brackets of 40 x 60mmHt with powder coated finish. MS LEGS: Made of Mild Steel 1.6 mm thickness powder coated with 60 microns round tube inclined / Straight leg INTERMEDIATE COVERED LEG: Made of 1.2mm Thick Mild steel Sheet Powder coated to 60 Microns, Covered stump considered for wire accessing Mild steel stump 450/600mm width CENTER T LEG : MS 50X50 Square leg with CRCA Pipe of 1.6mm thickness of 60 microns Powder coated leg for Table top Stability. MS CONNECTOR: 50X25mm Square CRCA Pipe of 1.6mm thickness of 60microns Powder coated connector for Table top support. HORIZONTAL RACEWAYS Made of 1mm Thick mild steel Sheet Powder coated to 60 Microns, Horizontal raceways face plate cutting 75mm deep & 120mm ht provided below the table top for electrical, Date wire management & Socket fixing. FLIP UP BOX : Flip ups are made in aluminium extrusion with Anodized finish. And it’s also provided with Single opening access. SIZE : 400X145MM METAL PERFORATED MODESTY PANEL - MAIN CONSIDERED. Made of 1mm thick Mild steel sheet with 60 microns Powder coated Modesty panel provided below the table top privacy, Main & End to End.

31

-

-

... More
CEO CABIN TABLE

-

-

-

... More
MAIN TABLE SIZE : 2100X900X750 MM HT RETURN COMBO STORAGE UNIT : 2100X600X750MM HT Sunon Model number: DR87L-2.256220 Executive desk or Equivalent TABLE TOP : Table top is made of 25mm thick Pre.Lam particle board with 2mm PVC Edge banding supported on Mild steel Powder coated legs IO LEGS: Made of Mild Steel 1.6 mm thickness powder coated with 60 microns round tube inclined leg (300mm HT SS-304 grade adjustable legs) with ‘SS’ leveler. MS CONNECTOR: 50X25mm Square CRCA Pipe of 1.6mm thickness of 60microns Powder coated connector for Table top support. 3WAY FLIP UP BOX : Flip up are made in aluminum extrusion with Anodized finish. And it’s also provided with 3way opening access. SIZE : 400x145 MM CABLE DUMP BOX Dump box Made of 1mm Thick CRCA Sheet Powder coated to 60 Microns, with size of 500mm length , 220mm deep & 120mm ht provided below the table top for electrical, Date wire management & Socket fixing. METAL PERFORATED MODESTY PANEL : Made of 1mm thick Mild steel sheet with 60microns Powder coated Modesty panel provided below the table top privacy. VERTICAL RAISER : Vertical raiser Made of 1mm Thick CRCA Sheet Powder coated to 60 Microns, with size of 75mm length , 75mm deep & 605mm ht provided below the dump box for Wire management from floor. RETURN COMBO STORAGE UNIT : Made of 18mm thick pre.laminated particle board with 2mm PVC Edge banding finishes top, Shutter & shelves. Handle : PVC Recessed Flush handle Lock : Cylindrical Regular Lock

1

-

-

... More
CABIN TABLE MAIN TABLE SIZE : 1650X800X750 MM HT RETURN COMBO STORAGE UNIT : 1000X450X750MM HT TABLE TOP : Table top is made of 25mm thick Pre.Lam particle board with 2mm PVC Edge banding supported on Mild steel Powder coated legs IO LEGS: Made of Mild Steel 1.6 mm thickness powder coated with 60 microns round tube inclined leg (300mm HT SS-304 grade adjustable legs) with ‘SS’ leveler. MS CONNECTOR: 50X25mm Square CRCA Pipe of 1.6mm thickness of 60microns Powder coated connector for Table top support. 3WAY FLIP UP BOX : Flip up are made in aluminum extrusion with Anodized finish. And it’s also provided with 3way opening access. SIZE : 400x145 MM CABLE DUMP BOX Dump box Made of 1mm Thick CRCA Sheet Powder coated to 60 Microns, with size of 500mm length , 220mm deep & 120mm ht provided below the table top for electrical, Date wire management & Socket fixing. METAL PERFORATED MODESTY PANEL : Made of 1mm thick Mild steel sheet with 60microns Powder coated Modesty panel provided below the table top privacy. VERTICAL RAISER : Vertical raiser Made of 1mm Thick CRCA Sheet Powder coated to 60 Microns, with size of 75mm length , 75mm deep & 605mm ht provided below the dump box for Wire management from floor. RETURN COMBO STORAGE UNIT : Made of 18mm thick pre.laminated particle board with 2mm PVC Edge banding finishes top, Shutter & shelves. Handle : PVC Recessed Flush handle Lock : Cylindrical Regular Lock

17

-

-

... More
DISCUSSION TABLE

-

-

-

... More
SIZE : 1200 MM DIA X750 MM HT TABLE TOP : Table top is made of 25mm thick Pre.Lam particle board with 2mm PVC Edge banding supported on Mild steel Powder coated legs IO LEGS: Made of Mild Steel 1.6 mm thickness powder coated with 60 microns round tube inclined leg (300mm HT SS-304 grade adjustable legs) with ‘SS’ leveler. MS CONNECTOR: 50X25mm Square CRCA Pipe of 1.6mm thickness of 60microns Powder coated connector for Table top support. 3WAY FLIP UP BOX : Flip up are made in aluminum extrusion with Anodized finish. And it’s also provided with 3way opening access. SIZE : 400x145 MM CABLE DUMP BOX Dump box Made of 1mm Thick CRCA Sheet Powder coated to 60 Microns, with size of 500mm length , 220mm deep & 120mm ht provided below the table top for electrical, Date wire management & Socket fixing. VERTICAL RAISER : Vertical raiser Made of 1mm Thick CRCA Sheet Powder coated to 60 Microns, with size of 75mm length , 75mm deep & 605mm ht provided below the dump box for Wire management from floor.

7

-

-

... More
MEETING TABLE :ECOSYSTEM

-

-

-

... More
6PAX MEETING TABLE SIZE: 2250X1200X750 MM HT - 2 NOS FLIP UP BOX CONSIDERED

2

-

-

... More
BOARDROOM TABLE SIZE: 5500X1800X750 MM HT 1. Configuration: Rectangular negotiation table 2. Material and Finish: E0-grade malemine; Desktop with ABS laser edge banding 3. Understructure: 4. Wiring: Standard configuration: Two silver aluminum alloy double-sided flippable wire boxes, eight 86-type sockets are optional; Sunon Model number: Customized DR78-2.480160 Conference table or Equivalent TABLE TOP : Table top is made of 25mm thick Pre.Lam particle board with 2mm PVC Edge banding supported on Mild steel Powder coated legs IO LEGS: Made of Mild Steel 1.6 mm thickness powder coated with 60 microns round tube inclined leg (300mm HT SS-304 grade adjustable legs) with ‘SS’ leveler. MS CONNECTOR: 50X25mm Square CRCA Pipe of 1.6mm thickness of 60microns Powder coated connector for Table top support. INTERMEDIATE COVERED LEG : 50X50mm Square CRCA Pipe of 1.6mm thickness of 60 microns Powder coated Covered leg considered for wire accessing HORIZONTAL RACEWAYS :- Mild Steel, 1mm Thickness of 60 microns Powder coated Horizontal raceways 120mm ht provided below table top for electrical wire management.. FLIP UP BOX : Flip up are made in aluminum extrusion with powder coating finish. And it’s also provided with Single opening access. SIZE : 420X150MM

1

-

-

... More
Specifications same as above but Board room table size: 5250x1200x750mm Ht

1

-

-

... More
Filing Compactor :

-

-

-

... More
Providing and fixing of filing compactor (Optimizer 457x 915 x 1980mm) units of Wintech,Kompress or approved equivalent make as per manufacturer's specification (all sample & record room) etc., complete complying with standard specification and as directed by the "Engineer-in-charge"

10

-

-

... More
CHAIRS

-

-

-

... More
WORKSTATION & RECEPTION AND PA

-

-

-

... More
MODEL: IRON; Code: CIR69SW Finish: Black nylon frame with Black nylon support Arms: 2D Adjustable Armrest - Height and front and back. Backrest:Mesh back Seat: Fabric elastic foam seat with mesh covered Mechanism: Synchronized tilting mechanism with Three-positions locking Lumbar Support: Height Adjustable lumbar support with cushion. Cylinder: High quality gas-lift Base: Black nylon Five-Star base with PA Castors 10 Years warranty: BIFMA Certified

133

-

-

... More
MEETING ROOM CHAIR

-

-

-

... More
MODEL: MAGNA; Code: CMG10GS Finish: PP Frame with chrome metal support Arms: PP fix armrest Back & PP back with PP seat Base: Metal base in chrome finish with PA castors. 10 Years warranty: BIFMA Certified

44

-

-

... More
BOARD ROOM CHAIR

-

-

-

... More
MODEL: ALIEN ; Code: CAI60SW CAI60SW-Medium back chair with white frame,Back : Mesh back ,Seat fabric elastic foam, with seat shell, STG with 4-position locking PA caster. Backrest Strenght Test- Static (Proof Load)/ There shall be no sudden and major change in the structural integrity (loss of serviceability is acceptable) When a force of 1001N (225lbf) is applied 70 degree ± 10 degree to the back at 406mm (16in) above the seat for 1 minute. Drop Test- Dynamic (Proof Load) (Clause 7)/ There shall be no sudden and major change in the structural integrity (loss of serviceability is acceptable) When a 136kg (300lb) weight free falls from 152mm (6in). Swivel Test- Cyclic (Clause 8)/ There shall be no loss of serviceability after 120000 cycles of rotation with a 122kg (270lb) load on the seat (for the seat height is adjustable, test 60000 cycles in its highest position then 60000 cycles in its lowest position. Tilt Mechanism Test/ There shall be no loss of Serviceability after moving the mechanism between the front and back stops for 300000 cycles with a 109kg (240lb) load on the seat. Seating Durability Tests/ There shall be no loss of serviceability after loading two seat front corner with 890N (200lbf) for 20000 cycles respectively Rear Stability Test/ The chair shall not tip over when applying 13 disks on the seat against backrest support fixture Front Stability the chair shall not tip over when applying a horizontal outward for of 20N (4.5lbf) from the seat with a vertical load of 61 kg (135lbf) at a point 60mm (2.4in) from the front center edge of the load bearing surface of the seat Arm strength report : There shall be no sudden and major change in structural integity (Loss of serviceability is acceptable) when a force of 1125N (253lbf) is applied vertically to the armrest for 15s. Backrest durability:There shall be no loss of Serviceability when a force of 445N (100lbf) is applied 90 degree ± 10 degree to the back at 406mm (16in) above the seat for 120000 cycles with 109kg (240lbs) weighton the seat. castors:There shall be no loss of Serviceability after cycling a travel of (762±50)mm ((30±2) for 2000 cycles over a surface with obstacles and then 98000 cycles over a surface with obstacles with a 122kg (270lb) load on seat. The Castor should not seaparate under 22N (5lbs) pulling Force ,the agency should provide Manufacturers warranty and BIFMA Certificate etc,as per approved drawing colour and shade by Engineer in charge, including all incidental and operational charges, Transportation ,labour charges, and all taxes Excluding GST etc., complete as directed by Engineer In Charge for finished item of work for all floors and at all levels.(Make:SUNON/Equivalent)

48

-

-

... More
CABIN ROOM CHAIR (Regular)

-

-

-

... More
MODEL: BUTTERFLY; Code: CBF60SW Finish: White nylon Frame Arms: Grey 2D PU adjustable armrest Backrest: Mesh back Seat: Fabric elastic foam seat with PP shell Mechanism: Italy DONATI automatically tension control system with Four-positions Cylinder: High quality gas-lift Base: Aluminum Five-Star base with PU Castors 10 Years warranty: BIFMA Certified

17

-

-

... More
CABIN ROOM CHAIR (Executive)

-

-

-

... More
MODEL: COUPE ; Code: CCP83SQ Finish: Polywood Frame with aluminum alloy support Arms: Wooden armrest with soft pad on the top Backrest: White ABS and full leather back The backrest enables tilting of 90 to 122 degrees, while the cushion enables synchronous tilting of 0 to 13 degrees. The four-gear lock allows you to personalize your comfort and PU nylon casters feature 360-degree free rotation and silent movement. Seat: Full leather seat ,The cushion of Coupe employs a scientific mix of firm, medium, and soft foam to better disperse and relieve pressure. The three-stage foam gives you appropriate support all the way from hip to ankle. Headrest: Full leather headrest Mechanism: STG automatically tension control system with Four-Position locking Cylinder: High quality gas-lift Base: Aluminum alloy five-star base with PU castors 10 Years warranty: BIFMA Certified

1

-

-

... More
VISITOR CHAIR (Regular)

-

-

-

... More
MODEL: IRON; Code: CIR71GW-2 Finish: Black nylon frame with Black nylon support Arms: Fixed Armrest Backrest:Mesh back Seat: Fabric elastic foam seat with mesh covered Lumbar Support: Height Adjustable lumbar support with cushion. 10 Years warranty: BIFMA Certified

35

-

-

... More
VISITOR CHAIR (Executive)

-

-

-

... More
MODEL: COUPE ; Code: CCP63SQ Finish: Polywood Frame with aluminum alloy support Arms: Wooden armrest with soft pad on the top Backrest: White ABS and full leather back The backrest enables tilting of 90 to 122 degrees, while the cushion enables synchronous tilting of 0 to 13 degrees. The four-gear lock allows you to personalize your comfort and PU nylon casters feature 360-degree free rotation and silent movement. Seat: Full leather seat ,The cushion of Coupe employs a scientific mix of firm, medium, and soft foam to better disperse and relieve pressure. The three-stage foam gives you appropriate support all the way from hip to ankle. Mechanism: STG automatically tension control system with Four-Position locking Cylinder: High quality gas-lift Base: Aluminum alloy five-star base with PU castors. 10 Years warranty: BIFMA Certified

2

-

-

... More
TRAINING ROOM CHAIR

-

-

-

... More
MODEL: Diamond ; Code:CDM15GW & CDM30PJ Size:560*555*805 Finish: Black nylon Frame with metal support Arms: Black fixed PP armrest Back & Seat: Mesh back and mesh seat with black seat shell Base: Silver Sled metal base in powder coated finish with 4 castors *Flexible back castor accompanied with stable front nail satisfies different needs of various spaces. Wisdom emerges from a simple push and pull. *The fold ability offers limited meeting space with endless possibility. Writing Board: PA Tablet 10 Years warranty: BIFMA Certified

95

-

-

... More
CAFETERIA CHAIRS

-

-

-

... More
MODEL: PLIS ; Code: CPS10GS Finish: PP chair stackable ,PP+ 15% Glass fiber chair back pass 1001N loading intensity test. Stackable Chair 10 Years warranty: BIFMA Certified

33

-

-

... More
CAFETERIA HIGH CHAIRS

-

-

-

... More
MODEL: DUCKY ; Code: CDK19GS Size:460*480*935 Chair back and seat: pp+30% glass fiber, pass 1001N loading intensity test. leg: 2mm thickness steel tube leg. 136kg loading ability. 1. The curve of the seat, perfectly supports your hip; 2. The 105°-inclined backrest, effectively supports your lumbar; 3. The 97°-folded edges of the back and seat. 5 colors available for choice for the back frame 10 Years warranty: BIFMA Certified

7

-

-

... More
LOOSE FURNITURES

-

-

-

... More
Supplying of loose furnitures including packaging, loading, unloading, freight charges etc.,

-

-

-

... More
2 SEATER SOFA W1450 X D775 X H825mm Model: Konark-2seater Shell & structure entirely made with Hardwood Foam: Average density 32-40 kg/m3 Base:Wooden legs Upholstery Finish in Fabric

4

-

-

... More
2 SEATER SOFA W1200 X D650 X H750mm Model: Istaka-2seater Shell & structure entirely made with Hardwood Foam: Average density 32-40 kg/m3 Base:Wooden legs Upholstery Finish in Fabric

4

-

-

... More
Curved sofa Model: Curve sofa custom D8B Size: W2400 x D750 x H885mm Curved shape sofa in Seating & Backrest : Fabric Base: MS Legs

3

-

-

... More
1 Seater Sofa Model: Autumn Size: W 620 x D 600 x H 790mm Specifications: Steel frame manufactured in CNC machines and joined on fixtures with metal inter gas welding Foam: Injection molded with awerage density 50-55 kg/m3 Base: wooden legs Upholstery finish in Fabric.

12

-

-

... More
1 Seater Sofa Model: Bridgette Size: W 600 x D 590 x H 800mm Specifications: Steel frame manufactured in CNC machines and joined on fixtures with metal inter gas welding Foam: Injection molded with awerage density 50-55 kg/m3 Base: wooden legs Upholstery finish in Fabric.

38

-

-

... More
Center Table - Round Size: Dia 450 X H 450mm Model: Cork Table top : Polished Veneer Base: MS Powder Coating

20

-

-

... More
Center Table - Round Size: Dia 600 X H 450mm Model: Cork Table top : Polished Veneer Base: MS Powder Coating

6

-

-

... More
Center Table - Round Size: Dia 900 X H 450mm Model: Cork Table top : Polished Veneer Base: MS Powder Coating

2

-

-

... More
SquareTable Size: W1400 x D600 x H550mm Model: Custom Table top : Laminated Base: MS Powder Coated legs

5

-

-

... More
SquareTable Size: W 900X D 600X H 550 mm Model: Custom Table top : Laminated Base: MS Powder Coated legs

6

-

-

... More
Pouf seater

-

-

-

... More
Square Pouffe Size: 450x450mm Specification: Multipurpose pouf structured with solid wood bringing in durability and providing backing to the high resilience foam on the outside that is upholstered with great quality fabric.

2

-

-

... More
Pouffe Size: Dia450 x H450mm Specification: Multipurpose pouf structured with solid wood bringing in durability and providing backing to the high resilience foam on the outside that is upholstered with great quality fabric.

-

-

-

... More
Square Pouffe Size: 600x600mm Specification: Multipurpose pouf structured with solid wood bringing in durability and providing backing to the high resilience foam on the outside that is upholstered with great quality fabric.

1

-

-

... More
Square Pouffe Size: Dia600 x H450mm Specification: Multipurpose pouf structured with solid wood bringing in durability and providing backing to the high resilience foam on the outside that is upholstered with great quality fabric.

-

-

-

... More
Cafetaria

-

-

-

... More
Center Tables - Circular Dia- 900 X 750mm Ht Model Number: Disc Top: Laminate Base Structure: Solid Wood Leg with Metal Cap. Base Finish: Solid Wood with Polish Edge Detail: Square or Chamfered

4

-

-

... More
Center Tables - Rectangular W 1200 X D 800 X H 750 Model Number: Timeout Top: Laminate Base Structure: Solid Wood Leg with Metal Cap. Base Finish: Solid Wood with Polish Edge Detail: Square or Chamfered

4

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.