Tamil Nadu Generation And Distribution Corporation Limited Tender

... More
The TANGEDCO has issued a formal invitation for competitive bids for the Tamil Nadu Generation And Distribution Corporation Limited project, for Mtps-i Es Em-i Unit-iii 1 Complete Overhauling Of 23 Nos Radiator Cooling Fan Motors 1.2kw Capacity Of The Generator Transformer Iii,0.5kw Capacity Of Uat-3a 3b 2 Stator Water Motor 3a 3 B 9.3kw Capacity During Unit Bunker 3 Restoration Period in Salem, Tamil Nadu. The bid opening date for this tender is 09-05-2025 and the last date for bid submission is 10-06-2025. Interested bidders for Tamil Nadu Generation And Distribution Corporation Limited tender can download the important documents here to check the tender amount, scope of work, eligibility criteria and technical requirements.

Tamil Nadu Generation And Distribution Corporation Limited - TANGEDCO Tender

Works
Electrical Generators And Transformers
Electrical and Electronics
Eprocure
Opening Date9 May 2025
Closing Soon10 Jun 2025
Tender AmountRefer Documents 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
MTPS-I ES EM-I Unit-III 1 Complete overhauling of 23 Nos Radiator cooling fan motors 1.2KW capacity of the Generator Transformer III,0.5KW capacity of UAT-3A 3B 2 stator water motor 3A 3 B 9.3KW capacity during Unit Bunker 3 restoration period
MTPS-I ES EM-I Unit-III 1 Complete overhauling of 23 Nos Radiator cooling fan motors 1.2KW capacity of the Generator Transformer III,0.5KW capacity of UAT-3A 3B 2 stator water motor 3A 3 B 9.3KW capacity during Unit Bunker 3 restoration period
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Charges for complete overhauling of motor including dismantling, cleaning of the stator coils, checking the tightness of the stator wedges and applying one coat of insulating varnish, replacement of both DE and NDE bearings and assembling ( For Motor capacity up to 0.60 KW) (UAT 3A & 3B radiator cooling fan motor-0.5KW cap.)

4

-

-

... More
Charges for complete overhauling of motor including dismantling cleaning of the stator coils, checking the tightness of the stator wedges and applying one coat of insulating varnish, replacement of DE and NDE bearings and assembling of motor capacities ranges from 0.61 KW to 1.4KW (GT radiator cooling fans Old type- 8Nos , New type – 11 Nos.)

19

-

-

... More
Charges for Complete O/H of LT Motor 1.2 KW to 9.3 KW (Stator water motor – 3A&3B)

2

-

-

... More
Charges for metal filling , machining and replacement of worn out shaft / bearing seating surface of one side, checking of bearing housing, providing sleeve in the end cover of one side (If necessary) 1.2 KW to 9.3KW – 25 x 2 = 50 Nos.

50

-

-

... More
Charges for Refurbishment of pitted rotor shaft at DE and NDE ie. Grinding, Machining, Polishing and Repairing of 9.3KW Stator water motor 3A & 3B – 2 Nos.(If necessary)

2

-

-

... More
Charges for Refurbishment of pitted rotor shaft at DE and NDE ie. Grinding, Machining, Polishing and Repairing of 1.2 KW GT radiator cooling fan motor – 19 Nos.(If necessary)

19

-

-

... More
Charges Dynamic balancing of Rotor shaft & Fan of 9.3KW Stator water motor 3A & 3B – 2 Nos.(If necessary) – (If necessary)

2

-

-

... More
Charges for Painting with 2 coats of Motor.(As Per Data Sheet

7.843

-

-

... More
Bearing NDE 6304 ZZ/C3 (Make: SKF) (Old type 1.2KW GT radiator cooling fan motor)

8

-

-

... More
Bearing DE & NDE 6206 ZZ/C3 (Make: SKF) ( Old type DE & New type DE & NDE - 1.2KW GT radiator cooling fan motor)

30

-

-

... More
Bearing DE 6004 ZZ/C3 (Make: SKF) (0.5 KW UAT 3A & 3B radiator cooling fan motor)

4

-

-

... More
Bearing NDE 6004 ZZ/C3 (Make: SKF) (0.5 KW UAT 3A & 3B radiator cooling fan motor)

4

-

-

... More
Bearing DE 6209 ZZ/C3 (Make: SKF) Stator water motor

2

-

-

... More
End Sleeves for DE/NDE covers for 9.3KW (if necessary)

4

-

-

... More
End Sleeves for DE/NDE covers for (23Nos) 0.6 KW to 1.2KW (if necessary)

46

-

-

... More
Smoke Grey enamel paint 0.6 KW to1.2 KW ( 23Nos) - ¼ litre / each RCF motor (Including supporting angle and supporting channel)

6.25

-

-

... More
Dr. Beck’ varnish - 0.6 KW to 1.2 KW (23Nos)- ¼litre /each motor

6.25

-

-

... More
Emery sheet

15

-

-

... More
Oil seal

23

-

-

... More
Water header

23

-

-

... More
Thinner

2

-

-

... More
Cost of Consumables

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.