Rural Development And Panchayat Raj Department Tender
... More
The RDPR has issued a formal invitation for competitive bids for the Rural Development And Panchayat Raj Department project, for Tiruppur District-pkg No. 12/mgsmt/2025-26 Phase 2- Mulanur Block in Tiruppur, Tamil Nadu, with an estimated contract value of Rs. 1,40,51,000. The bid opening date for this tender is 01-05-2025 and the last date for bid submission is 16-05-2025. Interested bidders for Rural Development And Panchayat Raj Department tender can download the important documents here to check the scope of work, eligibility criteria and technical requirements.
Rural Development And Panchayat Raj Department - RDPR Tender
Civil And Construction
Road Construction
Eprocure
Opening Date1 May 2025
Closing Date16 May 2025
Tender Amount₹ 1,40,51,000
Costs
EMD
₹ 1,41,000Document Cost
Refer DocumentsTender Fee
Refer Documents
Summary
Tiruppur District-pkg No. 12/mgsmt/2025-26 Phase 2- Mulanur Block
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_RDTN_553249_12Bid Award Id
ViewTender No
DIPR/1714/Tender/2025Tender Authority
Rural Development And Panchayat Raj Department ViewPurchaser Address
-Website
http://tntenders.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
RUMBLE STRIPS COVERED WITH BITUMINOUS SURFACE
Provision of 1 nos. rumble strips covered with premix bituminous carpet, 15-20 mm high at centre, 250 mm wide placed at 1 m centre-to-centre at approved locations to control speed, marked with white strips of road marking.
5.63
-
-
... More
Providing and fixing of retro -reflectorised cautionary,mandatory and information sign as per IRC: 67 made of encapsulated lens type reflective sheeting vide clause 1701.2.3 fixed over aluminium sheeting ,1.5mm thick supported on a mild steel angle iron post 75mmX75mmx6mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450mmx450mmX600mm,600mm below ground level as per drawings and Technical Specification Clause 801 900mm Equilateral triangle or Size as per IRC :67-2001.
4
-
-
... More
2) Strengthening to the Road from Peramium to Ayyampalayam - MGR nagar road 0/0-3/350 (Working Reach 0/0-1/005) (R-56)
Clearing the light/scrub jungle by uprooting including all cutting charges and disposing of the products and clearing as directed by departmental officers including all incidental charges etc. complete.
MORD Specification 111, 112, 201
1447.2
-
-
... More
Supplying and erecting centering shuttering including necessary supports for plane surface in foundation and basement and in all floors for R C C column footing column plinth beam, beams, roof slabs, staircase steps, bed blocks, critical pier etc using mild steel sheets of size 90 x 60 cm and 10 guage stiffened, welded with mild steel angles of size 25mmx25mmx3mm for boarding laid over silver oak (country wood) scantlings of size 10cm x 6.5cm spaced of about 90cm centre to centre and supported by casurina props of 10cm to 13cm dia spaced at 75cm centre to centre complete complying with standard specifications and as directed by departmental officers including conveyance of all materials to site and proper centering etc complete. BGL
479.35
-
-
... More
Providing and applying Primer coat with bitumen emulsion (SS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.70 kg/sqm using mechanical means as per Technical Specification Clause 502
2364
-
-
... More
Cement concrete 1 : 3 : 6 mix using 40mm HBG metal for foundation including watering wherever necessary and laid in layers of not more than 15cm thick., compacting etc., complete complying with standard specifications and as directed.Clause 802, 803, 1202 & 1203
4.65
-
-
... More
Reinforced cement concrete M15 grade kilometre stone of standard design (size 1.65m x 0.45m x 0.15m) as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Clause 1703
Ordinary Kilometer Stone (Precast)
specification Clauses 1703
1
-
-
... More
Rumble strips ahead - 600 mm Equilateral triangle
1
-
-
... More
Providing and applying Primer coat with bitumen emulsion (SS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.70 kg/sqm using mechanical means as per Technical Specification Clause 502
4297.13
-
-
... More
GST Amount for providing Service to Government Contract Works for the above Works. { GST Amount is the Total GST Amount for overall quoted amount above this row in column "BB" for all works in this package}
(Refer Clause 13.2 & 13.3 of Section 2 of Instruction to Bidders (ITB) of SBD)
1
-
-
... More
Picking of Old matelled / B T surface up to 10 cm thick and disposal of scarified material with a lift upto 3m and lead upto 1000 m as per technical specification clause 301.4 as directed by the departmental officers
785
-
-
... More
Reinforced cement concrete M15 grade Hectometre stone of standard design (size 0.90 m x 0.15m x 0.15m) as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Clause 1703
HM stone (precast) - (size 0.90m x 0.15m x 0.15m)
specification Clauses 1703
4
-
-
... More
Cement concrete 1 : 3 : 6 mix using 20 mm HBG metal for foundation including watering wherever necessary and laid in layers of not more than 15cm thick., compacting etc., complete complying with standard specifications and as directed.Clause 802, 803, 1202 & 1203
171.52
-
-
... More
Reinforced cement concrete M15 grade kilometre stone of standard design (size 1.65m x 0.45m x 0.15m) as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Clause 1703
Ordinary Kilometer Stone (Precast)
specification Clauses 1703
1
-
-
... More
Provision for Road Furniture at T-Junction improvements
Providing and erecting of Retro - reflectorized cautionary , Mandatory and Informatory signs (without definition board) made out of High Intensity Prismatic Grade Sheeting confirming to Type - IV standards of IRC - 67: 2012 and ASTM D -09, Specification and fixed over 2mm thick Aluminium sheet fixed over a black supporting frame of25MMx25mmx3mm Mild steel angle and supported on a mild steel angle post 75x75x6 mm with a clear height of not less than 2.10m from the ground level to the bottom of the sign board and 0.60m below ground level. The sign post should be painted as per IRC 67-2012 and firmly fixed to the ground by means of properly designed foundadation with M15 grade cement concrete 45cmx45cmx60cm size including cost and conveyance of all materials , equipment , Machinary and labour with all leads and lifts, loading charges necessary for satisfactory completion of the work as directed by the engineer in charge. Higj intensity Retro Reflectro sheet shall consist of minimum coefficient of Retro - reflection as per Table 6.6 of IRC 67-2012. The retro - reflective sheeting shall be covered under 7 year warranty issued for field performance and a certified copy of three years outdoor exposure report shall be obtained as per IRC 67 - 2012 ( as per MORTH Specification No 801)
Stop Sign Board - 60 cm high Octagon
1
-
-
... More
Tack coat
Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion pressure distributor at the rate of 0.25 kg per sqm on the prepared granular surface treated with Primer cleaned with Hydraulic broom as per Technical Specification Clause 111, 112, 501, 511, 513, 900
3869.25
-
-
... More
Bituminous Concrete (BC)
Providing BC 25/30 mm Thick (Grade II Using VG30 Bitumen Providing and laying Bituminous Concrete to 25/30 mm thick using 0.13 cum of 19.00- 9.50 mm, 0.17 cum of 9.50-2.36 mm and 0.26 cum of 2.36 and below with 50.30 kgs of VG 30 bitumen for premixing per 10 sqm including cost and conveyance of all materials to CMP site, heating the bitumen and aggregate to required temperature and mixing them in required temperature in central hot mix plant 20-30 ton capacity, conveying the mix by tipper trucks to paver site, spreading the mix to uniform thickness of 30 mm with mechanical paver to the specified grades and cross sections and consolidated by 8-10 tonne Vibratory to the required density etc., including labour for attending to paver to site etc., including hire charges and fuel charges for 20-30 t CMP with bitumen boiler, tipper trucks, Paver Finisher, Vibratory roller and all other tools and plant required, including fuel and all other incidental charges etc., complete as per specification using CMP as per clause 507 of MORTH Rev-5
70.93
-
-
... More
Providing and fixing of retro -reflectorised Cautionary,mandatory and information sign as per IRC: 67 made of encapsulated lens type reflective sheeting vide clause 1701.2.3 fixed over aluminium sheeting,1.5mm thick supported on a mild steel angle iron post 75mmX75mmx6mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450mmx450mmX600mm,600mm below ground level as per drawings and Technical Specification Clause 801 - 600mm Equilateral triangle or Size as per IRC :67-2001
4
-
-
... More
Providing and fixing of typical MGSMT informatory sign board/ CIB with Logo and Maintenance board as per detailed specifications and drawing communicated by the Direcorate of Rural Development and Panchayat Raj
1
-
-
... More
Provision for Road Furniture at T-Junction improvements
Providing and erecting of Retro - reflectorized cautionary , Mandatory and Informatory signs (without definition board) made out of High Intensity Prismatic Grade Sheeting confirming to Type - IV standards of IRC - 67: 2012 and ASTM D -09, Specification and fixed over 2mm thick Aluminium sheet fixed over a black supporting frame of25MMx25mmx3mm Mild steel angle and supported on a mild steel angle post 75x75x6 mm with a clear height of not less than 2.10m from the ground level to the bottom of the sign board and 0.60m below ground level. The sign post should be painted as per IRC 67-2012 and firmly fixed to the ground by means of properly designed foundadation with M15 grade cement concrete 45cmx45cmx60cm size including cost and conveyance of all materials , equipment , Machinary and labour with all leads and lifts, loading charges necessary for satisfactory completion of the work as directed by the engineer in charge. Higj intensity Retro Reflectro sheet shall consist of minimum coefficient of Retro - reflection as per Table 6.6 of IRC 67-2012. The retro - reflective sheeting shall be covered under 7 year warranty issued for field performance and a certified copy of three years outdoor exposure report shall be obtained as per IRC 67 - 2012 ( as per MORTH Specification No 801)
Stop Sign Board - 60 cm high Octagon
1
-
-
... More
Earth work excavation and depositing on back with an initial of 10m and lift 2m in sand, silt or other loose soil, wet sand or silt not under water, light black cotton soil, sandy loam and ordinary soil including excavated earth etc., as per SS 20 B including laying and spreading in layers of 250 mm loose thick each, sectioning , watering and compacting by Power roller to achieve the required Proctor density at 100% compaction at optimum moisture content as determined in occurrence with complete as per MoRD 111, 112, 202, 900, 301, 304
472.5
-
-
... More
Providing and fixing of retro -reflectorised cautionary,mandatory and information sign as per IRC: 67 made of encapsulated lens type reflective sheeting vide clause 1701.2.3 fixed over aluminium sheeting ,1.5mm thick supported on a mild steel angle iron post 75mmX75mmx6mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450mmx450mmX600mm,600mm below ground level as per drawings and Technical Specification Clause 801 900mm Equilateral triangle or Size as per IRC :67-2001.
6
-
-
... More
RUMBLE STRIPS COVERED WITH BITUMINOUS SURFACE
Provision of 1 nos. rumble strips covered with premix bituminous carpet, 15-20 mm high at centre, 250 mm wide placed at 1 m centre-to-centre at approved locations to control speed, marked with white strips of road marking.
5.63
-
-
... More
Providing and laying Gravel including cost and conveyance of gravel from approved sources to work site including labour for spreading , watering and compacting by power roller to achieve the required protect density at 100% compaction at optimum moisture content and hire & fuel charges for power roller, water sprinkler and all other incidental charges such as traffic barricading and providing danger lights etc., complete.MORD Specification 111, 112, 401, 900 Km 2/49-3/0
181.8
-
-
... More
Picking of Old matelled / B T surface up to 10 cm thick and disposal of scarified material with a lift upto 3m and lead upto 1000 m as per technical specification clause 301.4 as directed by the departmental officers
1283.75
-
-
... More
RUMBLE STRIPS COVERED WITH BITUMINOUS SURFACE
Provision of 1 nos. rumble strips covered with premix bituminous carpet, 15-20 mm high at centre, 250 mm wide placed at 1 m centre-to-centre at approved locations to control speed, marked with white strips of road marking.
5.63
-
-
... More
Strengthening to the Road from Venkikalpatty to Dist limit (West end) 0/0 - 0/650 (Working Reach 0/0-0/610) (R-126)
Clearing the light/scrub jungle by uprooting including all cutting charges and disposing of the products and clearing as directed by departmental officers including all incidental charges etc. complete.
MORD Specification 111, 112, 201
805.2
-
-
... More
Cement concrete 1 : 4 : 8 mix using 40mm HBG metal for foundation including watering wherever necessary and laid in layers of not more than 15cm thick., compacting etc., complete complying with standard specifications and as directed.Clause 802, 803, 1202 & 1203
0.6
-
-
... More
Granular subbase - Gr.III
Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with three wheel 80-100 kN static roller capacity to achieve the desired density, complete as per Technical Specification Clause 401 Grading III
483.23
-
-
... More
Hazard Marker Traffic signs - Type - IV Providing and Erecting of Retro - Reflectorised Hazard Marker Traffic Sign made out of High Intensity Prismatic Grade Sheeting confirming to Type-IV standards of IRC-67: 2012 and ASTM D 4956-09, specification and fixed over 2mm thick Aluminium sheet fixed over a back supporting frame of 25mmx25mmx3mm Mild Steel angle and supported on a mild steel angle post 75X75X6mm and 0.60m below ground level. The sign post should be painted as per IRC 67-2012 and firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45cmX45cmX60cm size including cost and conveyance of all materials, equipment, Machinery and labour with all leads and lifts, loading charges necessary for satisfactory completion of the work as directed by the engineer in charge. High intensity Retro Reflectro sheet shall consist of minimum coefficient of Retro-reflection as per Table 6.6 of IRC 67-2012. The retro- reflective sheeting shall be covered under 7 year warranty issued for field performance and a certified copy of three years outdoor exposure report shall be obtained as per IRC 67:2012. (as per MORT&H Specification No.801)
4
-
-
... More
Wet Mix Macadam
Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the material with water at OMC in mechanical mixer (Pug Mill), carriage of mixed material by tipper to site, laying in uniform layers in subbase/base course on a well prepared sub-base and compacting with smooth wheel roller of 80 to 100kN weight to achieve the desired density including lighting, barricading and maintenance of diversion, etc as per Tables 400.11 & 400.12 and Technical Specification Clause 406.
644.57
-
-
... More
Major road ahead - 600 mm Equilateral triangle
1
-
-
... More
Providing and laying Gravel including cost and conveyance of gravel from approved sources to work site including labour for spreading , watering and compacting by power roller to achieve the required protect density at 100% compaction at optimum moisture content and hire & fuel charges for power roller, water sprinkler and all other incidental charges such as traffic barricading and providing danger lights etc., complete. MORD Specification 111, 112, 401, 900
213.5
-
-
... More
3) Upgradation to the Road from 13/5 of Vengikkalpatti road to 16/8 of same road 0/0 - 3/620 (Working Reach 2/495-3/62) (R-132).
Clearing the light/scrub jungle by uprooting including all cutting charges and disposing of the products and clearing as directed by departmental officers including all incidental charges etc. complete.
MORD Specification 111, 112, 201
1485
-
-
... More
Bituminous Concrete (BC)
Providing BC 25/30 mm Thick (Grade II Using VG30 Bitumen Providing and laying Bituminous Concrete to 25/30 mm thick using 0.13 cum of 19.00- 9.50 mm, 0.17 cum of 9.50-2.36 mm and 0.26 cum of 2.36 and below with 50.30 kgs of VG 30 bitumen for premixing per 10 sqm including cost and conveyance of all materials to CMP site, heating the bitumen and aggregate to required temperature and mixing them in required temperature in central hot mix plant 20-30 ton capacity, conveying the mix by tipper trucks to paver site, spreading the mix to uniform thickness of 30 mm with mechanical paver to the specified grades and cross sections and consolidated by 8-10 tonne Vibratory to the required density etc., including labour for attending to paver to site etc., including hire charges and fuel charges for 20-30 t CMP with bitumen boiler, tipper trucks, Paver Finisher, Vibratory roller and all other tools and plant required, including fuel and all other incidental charges etc., complete as per specification using CMP as per clause 507 of MORTH Rev-5
107.43
-
-
... More
Bituminous Concrete (BC)
Providing BC 25/30 mm Thick (Grade II Using VG30 Bitumen Providing and laying Bituminous Concrete to 25/30 mm thick using 0.13 cum of 19.00- 9.50 mm, 0.17 cum of 9.50-2.36 mm and 0.26 cum of 2.36 and below with 50.30 kgs of VG 30 bitumen for premixing per 10 sqm including cost and conveyance of all materials to CMP site, heating the bitumen and aggregate to required temperature and mixing them in required temperature in central hot mix plant 20-30 ton capacity, conveying the mix by tipper trucks to paver site, spreading the mix to uniform thickness of 30 mm with mechanical paver to the specified grades and cross sections and consolidated by 8-10 tonne Vibratory to the required density etc., including labour for attending to paver to site etc., including hire charges and fuel charges for 20-30 t CMP with bitumen boiler, tipper trucks, Paver Finisher, Vibratory roller and all other tools and plant required, including fuel and all other incidental charges etc., complete as per specification using CMP as per clause 507 of MORTH Rev-5
116.08
-
-
... More
Major road ahead - 600 mm Equilateral triangle
1
-
-
... More
Providing and Fixing reflective road studs of category A raised pavement markers made out of Poly carbonate / methyl methercrylate / ABS moulded body confirming to ASTM D 788 and reflective panels with micro prismatic lens capable of providing total internal reflection of the light entering the lens face with retro reflectance and chromically values conforming to ASTM D428. The reflective raised pavement markers shall also confirm to the MORTH circular No RW/NH. 33023/10*97- DO .III dt 11.06.97.The height, width and length shall not be less than 15 mm , 90 mm and 100 mm and with minimum re4flective area of 13 sq.cm on each side and the slope to the base shall be 35+/-5 degree . Each reflector shall have a CIL not less than values specified in Table 2 of sais MORTH circular . The strength of detachment of the integrated cylindrical shanks, ( of diameter not less than 19+/-2 mm and height not less than 30+/-2 mm) from the body is to be a minimum value of 500Kgf . Fixing will be by drilling holes on the road for the shanks to go inside, without nails and using epoxy resin based adhesive as per manufacturers recommandation and complete as directed by the engineer. The marker shall support a load of 13635 Kg tested in accordance with ASTM D4280 and confirming to IRC 35-2015 guidelines and MORTH specification 804 etc complete
50
-
-
... More
Supplying and erecting centering shuttering including necessary supports for plane surface in foundation and basement and in all floors for R C C column footing column plinth beam, beams, roof slabs, staircase steps, bed blocks, critical pier etc using mild steel sheets of size 90 x 60 cm and 10 guage stiffened, welded with mild steel angles of size 25mmx25mmx3mm for boarding laid over silver oak (country wood) scantlings of size 10cm x 6.5cm spaced of about 90cm centre to centre and supported by casurina props of 10cm to 13cm dia spaced at 75cm centre to centre complete complying with standard specifications and as directed by departmental officers including conveyance of all materials to site and proper centering etc complete. BGL
16.89
-
-
... More
Construction of Retaining wall for 108 m
Earth work Excavation for Foundation in all soils and Sub Soil to full depth as may be directed except in hard rock requiring blasting but inclusive of shoring strutting and requiring the sides of foundation.Clause 305.1
182.52
-
-
... More
Tack coat
Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion pressure distributor at the rate of 0.25 kg per sqm on the prepared granular surface treated with Primer cleaned with Hydraulic broom as per Technical Specification Clause 111, 112, 501, 511, 513, 900
2364
-
-
... More
Km 3/0-3/62
223.2
-
-
... More
Providing and fixing of typical MGSMT informatory sign board/ CIB with Logo and Maintenance board as per detailed specifications and drawing communicated by the Direcorate of Rural Development and Panchayat Raj
1
-
-
... More
Major road ahead - 600 mm Equilateral triangle
1
-
-
... More
Providing and Fixing reflective road studs of category A raised pavement markers made out of Poly carbonate / methyl methercrylate / ABS moulded body confirming to ASTM D 788 and reflective panels with micro prismatic lens capable of providing total internal reflection of the light entering the lens face with retro reflectance and chromically values conforming to ASTM D428. The reflective raised pavement markers shall also confirm to the MORTH circular No RW/NH. 33023/10*97- DO .III dt 11.06.97.The height, width and length shall not be less than 15 mm , 90 mm and 100 mm and with minimum re4flective area of 13 sq.cm on each side and the slope to the base shall be 35+/-5 degree . Each reflector shall have a CIL not less than values specified in Table 2 of sais MORTH circular . The strength of detachment of the integrated cylindrical shanks, ( of diameter not less than 19+/-2 mm and height not less than 30+/-2 mm) from the body is to be a minimum value of 500Kgf . Fixing will be by drilling holes on the road for the shanks to go inside, without nails and using epoxy resin based adhesive as per manufacturers recommandation and complete as directed by the engineer. The marker shall support a load of 13635 Kg tested in accordance with ASTM D4280 and confirming to IRC 35-2015 guidelines and MORTH specification 804 etc complete
50
-
-
... More
Reinforced cement concrete M15 grade Hectometre stone of standard design (size 0.90 m x 0.15m x 0.15m) as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Clause 1703
HM stone (precast) - (size 0.90m x 0.15m x 0.15m)
specification Clauses 1703
5
-
-
... More
Rumble strips ahead - 600 mm Equilateral triangle
1
-
-
... More
Providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7
55
-
-
... More
Providing and applying Primer coat with bitumen emulsion (SS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.70 kg/sqm using mechanical means as per Technical Specification Clause 502
3869.25
-
-
... More
Providing and fixing of typical MGSMT informatory sign board/ CIB with Logo and Maintenance board as per detailed specifications and drawing communicated by the Direcorate of Rural Development and Panchayat Raj
1
-
-
... More
Providing and Fixing reflective road studs of category A raised pavement markers made out of Poly carbonate / methyl methercrylate / ABS moulded body confirming to ASTM D 788 and reflective panels with micro prismatic lens capable of providing total internal reflection of the light entering the lens face with retro reflectance and chromically values conforming to ASTM D428. The reflective raised pavement markers shall also confirm to the MORTH circular No RW/NH. 33023/10*97- DO .III dt 11.06.97.The height, width and length shall not be less than 15 mm , 90 mm and 100 mm and with minimum re4flective area of 13 sq.cm on each side and the slope to the base shall be 35+/-5 degree . Each reflector shall have a CIL not less than values specified in Table 2 of sais MORTH circular . The strength of detachment of the integrated cylindrical shanks, ( of diameter not less than 19+/-2 mm and height not less than 30+/-2 mm) from the body is to be a minimum value of 500Kgf . Fixing will be by drilling holes on the road for the shanks to go inside, without nails and using epoxy resin based adhesive as per manufacturers recommandation and complete as directed by the engineer. The marker shall support a load of 13635 Kg tested in accordance with ASTM D4280 and confirming to IRC 35-2015 guidelines and MORTH specification 804 etc complete
25
-
-
... More
Construction of Retaining Wall at CH 790 m-795 m Earth work Excavation for Foundation in all soils and Sub Soil to full depth as may be directed except in hard rock requiring blasting but inclusive of shoring strutting and requiring the sides of foundation.Clause 305.1
9
-
-
... More
Earth work excavation and depositing on back with an initial of 10m and lift 2m in sand, silt or other loose soil, wet sand or silt not under water, light black cotton soil, sandy loam and ordinary soil including excavated earth etc., as per SS 20 B including laying and spreading in layers of 250 mm loose thick each, sectioning , watering and compacting by Power roller to achieve the required Proctor density at 100% compaction at optimum moisture content as determined in occurrence with complete as per MoRD 111, 112, 202, 900, 301, 304
329.4
-
-
... More
Reinforced cement concrete M15 grade Hectometre stone of standard design (size 0.90m x 0.15m x 0.15m) as per IRC:8 fixing in position including painting and printing, etc as per drawing and Technical Specification Clause 1703
3
-
-
... More
Provision for Road Furniture at T-Junction improvements
Providing and erecting of Retro - reflectorized cautionary , Mandatory and Informatory signs (without definition board) made out of High Intensity Prismatic Grade Sheeting confirming to Type - IV standards of IRC - 67: 2012 and ASTM D -09, Specification and fixed over 2mm thick Aluminium sheet fixed over a black supporting frame of25MMx25mmx3mm Mild steel angle and supported on a mild steel angle post 75x75x6 mm with a clear height of not less than 2.10m from the ground level to the bottom of the sign board and 0.60m below ground level. The sign post should be painted as per IRC 67-2012 and firmly fixed to the ground by means of properly designed foundadation with M15 grade cement concrete 45cmx45cmx60cm size including cost and conveyance of all materials , equipment , Machinary and labour with all leads and lifts, loading charges necessary for satisfactory completion of the work as directed by the engineer in charge. Higj intensity Retro Reflectro sheet shall consist of minimum coefficient of Retro - reflection as per Table 6.6 of IRC 67-2012. The retro - reflective sheeting shall be covered under 7 year warranty issued for field performance and a certified copy of three years outdoor exposure report shall be obtained as per IRC 67 - 2012 ( as per MORTH Specification No 801)
Stop Sign Board -60 cm high Octagon
1
-
-
... More
Rumble strips ahead - 600 mm Equilateral triangle
1
-
-
... More
Tack coat
Providing and applying Tack coat with Bitumen emulsion (RS-1) using emulsion pressure distributor at the rate of 0.25 kg per sqm on the prepared granular surface treated with Primer cleaned with Hydraulic broom as per Technical Specification Clause 111, 112, 501, 511, 513, 900
4297.13
-
-
... More
Earth work excavation and depositing on back with an initial of 10m and lift 2m in sand, silt or other loose soil, wet sand or silt not under water, light black cotton soil, sandy loam and ordinary soil including excavated earth etc., as per SS 20 B including laying and spreading in layers of 250 mm loose thick each, sectioning , watering and compacting by Power roller to achieve the required Proctor density at 100% compaction at optimum moisture content as determined in occurrence with complete as per MoRD 111, 112, 202, 900, 301, 304
607.5
-
-
... More
Cement concrete 1 : 4 : 8 mix using 40mm HBG metal for foundation including watering wherever necessary and laid in layers of not more than 15cm thick., compacting etc., complete complying with standard specifications and as directed.Clause 802, 803, 1202 & 1203
14.04
-
-